Loading...
HomeMy Public PortalAboutChatham Av_1408U.S. DEPARTMENT OF HOMELAND SECURITY FEDERAL EMERGENCY MANAGEMENT AGENCY National Flood Insurance Program Important: Read the instructions on pages 1 -9. ELEVATION CERTIFICATE OMB No. 1660 -0008 Expiration Date: July 31, 2015 SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name FRANKLYN AND DABNEY EDENFIELD Policy Number: A2. Building Street Address (including Apt, Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 1408 CHATHAM AVENUE Company NAIC Number. City TYBEE ISLAND State GA ZIP Code 31328 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT C OF A RESUBDIVISION OF LOTS 324 -326, WARD 4, TYBEE ISLAND A4. Building Use (e.g., Residential, Non - Residential, Addition, Accessory, etc.) A5. Latitude /Longitude: Lat. N 31 059'46.6_ Long. W 80 °51'13.8" A6. Attach at feast 2 photographs of the building if the Certificate is being used A7. Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 884 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 4 c) Total net area of flood openings in A8.b 1000 sq in d) Engineered flood openings? ® Yes ❑ No RESIDENTIAL Horizontal Datum: ❑ to obtain flood insurance. NAD 1927 ® NAD 1983 A9. For a building with an attached garage: a) Square footage of attached garage NA sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade NA c) Total net area of flood openings in A9.b NA sq in d) Engineered flood openings? ❑ Yes ❑ No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number CITY OF TYBEE ISLAND 135164 B2. County Name CHATHAM B3. State GEORGIA B4. Map /Panel Number 13051C0326 B5. Suffix F B6. FIRM Index Date 09 -26 -08 B7. FIRM Panel Effective /Revised Date 09 -26 -08 B8. Flood Zone(s) AE B9. Base Flood Elevation(s) (Zone AO, use base flood depth) 13 310. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other /Source: 311. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ® NAVD 1988 ❑ Other /Source: 312. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ►4 No Designation Date: ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) ;1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. :2. Elevations - Zones A1-A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, AR/A1 A30, ARJAH, AR/AO. Complete Items C2.a -h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: GDOT DISK BV 025-44 Vertical Datum: NGVD 1929 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 El NAVD 1988 ❑ Other /Source: Datum used for building elevations must be the same as that used for the BFE. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 7.6 b) Top of the next higher floor 16.6 c) Bottom of the lowest horizontal structural member (V Zones only) NA. d) Attached garage (top of slab) N. e) Lowest elevation of machinery or equipment servicing the building 15.9 (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 6.9 feet g) Highest adjacent (finished) grade next to building (HAG) 7.2 ® feet h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 7.0 ® feet Check the measurement used. ® feet El feet ❑ feet ❑ feet ® feet ►e ❑ meters ❑ meters ❑ meters ❑ meters ❑ meters ❑ meters ❑ meters ❑ meters SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ❑ Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a ® Check here if attachments. licensed land surveyor? ® Yes ❑ No :;ertifier's Name JAMES M. KEATON, RLS License Number GA #2743 Title LAND SURVEYOR address PO BOX 61649 Company Name CHATHAM SURVEYING SERVICES, INC City SAVANNAH State GA ZIP Code 31420 Signature Date JULY 24, 2013 Telephone 912 - 303 -0302 ¢4 o ■STER No. 2743 v- tied �y IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 1408 CHATHAM AVENUE FOR INSURANCE COMPANY USE . Policy Number. City TYBEE ISLAND State GA ZIP Code 31328 Company NAIC Number. SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments ITEM C2a IS STORAGE AND ACCESS ONLY AND IS NOT HEATED. ITEM C2b IS THE HABITABLE FLOOR. ITEM C2e IS EXTERIOR HVAC ON A WOODEN PLATFORM. ITEM C2h IS GRADE AT THE WOODEN DECK. THE VENTS ON ITEM A8b ARE ENGINEERED VENTS AND THE CERTIFICATION FOR THEM IS ATTACHED TO THIS FORM. Signature Date JULY 24, 2013 SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and /or 9 (see pages 8-9 of Ir)sttutc ions), the next- hjgher floor (elevation C2.b in the diagrams) of the building is . ❑ feet ❑ meters ❑ above or ❑ below the HAG. `t E3. Attached garage (top of slab) is . 0 feet ❑ meters ❑ above or ❑ below the HAG.}— .4,1. `I E4. Top of platform of machinery and /or equipment servicing the building is ❑ feet ❑ meters ❑ above or Q below.the HAG. _--" E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No 0 Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, 8, and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name 4ddress City State ZIP Code Signature Date Telephone ',omments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) e local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 -G10. In Puerto Rico only, enter meters. I. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) '. ❑ A community official completed Section E for a building located in Zone A (without a FEMA - issued or community- issued BFE) or Zone AO. ❑ The following information (Items G4 -G10) is provided for community floodplain management purposes. 14. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance /Occupancy Issued This permit has been issued for. ❑ New Construction ❑ Substantial Improvement . Elevation of as -built lowest floor (including basement) of the building: . BFE or (in Zone AO) depth of flooding at the building site: 0. Community's design flood elevation: ❑ feet ❑ meters Datum ❑ feet ❑ meters Datum ❑ feet ❑ meters Datum )cal Official's Name Title ommunity Name Telephone gnature Date omments ❑ Check here if attachments. ELEVATION CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 1408 CHATHAM AVENUE FOR INSURANCE COMPANY USE Policy Number: City TYBEE ISLAND State GA ZIP Code 13128 Company NAIC Number. If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View" and "Rear View "; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. PHOTOGRAPHS TAKEN JULY 19, 2013 FRONT VIEW LEFT SIDE VIEW ELEVATION CERTIFICATE, page 4 Building Photographs Continuation Page IMPORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. 1408 CHATHAM AVENUE FOR INSURANCE COMPANY USE Policy Number. City TYBEE ISLAND State GA ZIP Code 31328 Company NAIC Number. If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View "; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. REAR VIEW RIGHT SIDE VIEW State of Georgia Certificate of Compliance Tuesday, July 23, 2013 Dabney and Franklin Edenfeld 1408 Chatham Avenue Tybee Island, GA 31328 In accordance with Home Land Security — FEMA/NFIP Technical Bulletin 1 /August 2008 requirements for engineered openings in foundation walls, USA FLOOD /AIR FOUNDATION FLOOD VENT will allow for the automatic equalization of hydrostatic flood forces and pressure during flooding as well as for base 100 year flood or 1% chance of flooding in NFIP FIRM (Federal Insurance Rate Map) "A" zone properties. Additional information to meet FEMA/NFIP requirements for flood venting can be found in TB -1 /August 2008. The International Code Council (ICC) requires a minimum 3" diameter opening to be maintained during flooding to allow passage of debris through a flood vent. USA FLOOD /AIR FOUNDATION FLOOD VENT meets the regulation of Federal Emergency Management Agency's National Flood Insurance Program (44 CFR 60.3 (c) (5)) and Flood Resistant Design and Construction (ASCE 24 -98). I do by certify the USA FLOOD /AIR FOUNDATION FLOOD VENTS openings are designed for installation in buildings to meet the FEMA, NFIP and ICC code requirements for the equalizing of hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater during floods up to and including the base (100 year) flood. USA FLOOD /AIR VENTS provide hydrostatic pressure equalization during a flood. Each vent will cover 250 square feet of enclosed building area as per FEMA, NFIP or ICC instructions and calculations. I further certify that the breakaway door releases under less than the required 20 lbs. of hydrostatic pressure. The vents must be installed with the long dimension horizontal and the installation must be in accordance with the manufacturer's printed instructions. Jason M. Conn, P.E. 16360 Trotter Lane Linden, MI 48451 810 -458 -4350 GA License No. PE033867 No. PE033867 PROFESSIONAL `/100%"''',1/4,0S