Loading...
HomeMy Public PortalAboutCEDARWOOD DR_9City of Tybee Island • Planning & Zoning Dept. Inspection Report 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328 Phone 912.472.5032 • Fax 912.786.9539 Permit No Date Requested 5 INTERNATIONAL CODE COUNCIlf MEMBER Owner's Name 1 Date Needed Gen. Contractor Subcontractor Contact Information Project Address Scope of Work 14/,11 (A.)) ,367 72iZz: /2-p I i Inspector Date of Inspection Inspection Pass El Fail Fee 119 , / / Inspection Pass Fail Fee Inspection Pass Fail Fee Inspection Pass Fail 0 Fee DATE ISSUED: 03 -6 -2013 WORK DESCRIPTION CITY OF TYBEE ISLAND BUILDING PERMIT WIRING/RECEPTACLES /LIGHTING WORK LOCATION 9 CEDARWOOD OWNER NAME CITY OF TYBEE ADDRESS PO BOX 2749 CITY, ST, ZIP TYBEE ISLAND GA 31328 -2749 PHONE NUMBER CONTRACTOR NAME PACE ELECTRICAL CONTRACTORS ADDRESS 9 -A EXECUTIVE CIRCLE CITY STATE ZIP SAVANNAH GA 31406 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 69.00 PROPERTY IDENTIFICATION # PIN #4- 0002 -18 -006 PROJECT VALUATION $4,664.00 PERMIT #: 130153 TOTAL BALANCE DUE: $ 69.00 It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire, soil and sedimentation, wetlands, marshlands protection and shore protection ordinances and codes whether local, state or federal, including all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: P. 0. Box 2749 - 403 Butler Avenue, Tybee Island, Georgia 31328 (912) 786 -4573 - FAX (912) 786 -9539 www.cityoftybee.org /3- ot53 CITY OF TYBEE ISLAND BUILDING & ZONING DEPARTMENT P.O. Box 2749, Tybee Island, GA 31328 Phone (912) 786 -4573 Fax (912) 786 -9539 ELECTRICAL PERMIT APPLICATION & TEMPORARY SERVICE AFFIDAVIT Date q aD44/ °o P Pe • )( New Work Replacement Location of work (street address) ( k t( Mod -4ffitctr{, Contractor YO%-6 E l IY at ( (f ki(,t , (1 L Telephone -- " et 4 3c- `T Address of Contractor P")\ a jl) N VC . b.v 1o,1 (611 Lit-Fec.)- Property Owner 1l✓ Iote 'P is AC l i Cn Telephone i a - l s • J at Date work will be ready for inspection, if known t IIII�� co eVl.� Estimated cost of construction *11444, A/C Unit and Heat Pump Attic Ventilation Fan Bell Transmitter — low voltage Border /Outline Lighting Building Saw Exit Lights — life safety Heat Pump Meter Box Motor(s): hp Outlets — 1 1 0 volts circuit Parking Lot Lights X, Pool Lights — grounding Range — commercial *11444, Permit Number ALL wiring, service included, must be COPPER. NO aluminum allowed. Means shall be provided to disconnect all conductors from the service - entrance conductors. NEC 230.70 APPLICATION FOR TEMPORARY SERVICE REQUEST In requesting temporary electrical service, the undersigned understands and agrees: 1. Connection of temporary electrical service does not remove the requirement to comply with all State of Georgia minimum construction codes. 2. Temporary electrical power is intended for completion of the construction process and testing equipment installed within the structure. 3. Issuing approval for temporary power connection does not constitute approval to occupy the structure. A Certificate of Occupancy must be issued by the City of Tybee Island prior to any occupancy. 4. The owner and contractor are hereby held responsible for any violations of this policy. A violation of this policy may result in disconnection of the electrical service until all violations and deficiencies are corrected. Owner /Contractor Signature Date PAD L RowJ,i 1 Owner /Contractor Printed Name • APPROVAL Fee Building Official / /�� Date 5443 Range Hood — commercial Service: amps Sign Circuit - wattage Smoke Detector — low voltage Spa or Tub — grounding Special Outlet Swimming Pool — grounding Water Heater Welder— 220 volts circuit Well Pump — grounding X -ray X, Other Permit Number ALL wiring, service included, must be COPPER. NO aluminum allowed. Means shall be provided to disconnect all conductors from the service - entrance conductors. NEC 230.70 APPLICATION FOR TEMPORARY SERVICE REQUEST In requesting temporary electrical service, the undersigned understands and agrees: 1. Connection of temporary electrical service does not remove the requirement to comply with all State of Georgia minimum construction codes. 2. Temporary electrical power is intended for completion of the construction process and testing equipment installed within the structure. 3. Issuing approval for temporary power connection does not constitute approval to occupy the structure. A Certificate of Occupancy must be issued by the City of Tybee Island prior to any occupancy. 4. The owner and contractor are hereby held responsible for any violations of this policy. A violation of this policy may result in disconnection of the electrical service until all violations and deficiencies are corrected. Owner /Contractor Signature Date PAD L RowJ,i 1 Owner /Contractor Printed Name • APPROVAL Fee Building Official / /�� Date 5443 Gmail - TAA - Lighting Bids Page 1 of 1 TAA - Lighting Bids 1 message Tommy Thompson <thomasfstop @gmail.com> Tommy Thompson <thomasfstop @gmail.com> Mon, Feb 4, 2013 at 8:42 PM To: Samantha Claar <samanthaclaar @bellsouth.net >, Dorisgrieder @aol.com Hi Samantha and Doris, Attached are copies of the two bids received for the proposed lighting improvements to the TAA Arts Center at 7 Cedarwood Ave. As you can see there is a considerable difference between the two bids. Unfortunately, this is not uncommon which is the reason for trying to get three or more bids on a project. Pace Electric was the only contractor that attended the pre -bid meeting and had the advantage of reviewing the building and accessing the level of difficulities to install the proposed improvements. Since both bids were based on the same materials, so if you give ProLectric the benefit of the doubt, maybe their higher bid assumed more difficulty (higher labor costs) in completing the work. Or maybe they just threw in a huge number thinking no one else was bidding who knows...! I'm very disapointed that the other contractors Braddy Electric, Wade Electric and Russell Electric decided not to bid on the project. The bid from Pace is consistent with the budget estimate received from Russell Electric, when you consider that the Russell quote did not include the additional convenience outlets, Flourescent Fixtures, Floor Receptables, etc. My recommendation is to have the Board meet with Pace Electric, review their bid in detail and if no discrepantcies are found to award them a contract for the Lighting Improvements. Sincerely, Tommy TA A M:-I-AA/NA ._-It vezt-;!' "/-4-t J 4/0L-14-2 "- q a"-a_ ayi.-p/e http: / /mail.google.com /mail /u/0 / ?ui= 2 &ik =f 7a98186d6 &view =pt &search = sent &th =13 ca80... 2/6/2013 131 SOUTHERN BLVD SAVANNAH, GEORGIA 31405 912- 920 -7324 FAX 912 - 920 -7323 PACE ELEC 1 s'' = C CONTRACTORS, INC. January 25, 2013 Tommy Thompson Re: Tybee Arts Association (Electrical Work) We hereby propose to furnish all labor, material, and supervision necessary to provide the Electrical Installation for the above referenced project. Clarifications: Price includes wiring for & installing eight duplex receptacles along baseboards in wire mold. Price includes replacing five duplex receptacles. Price includes three new 15amp circuits, one for new receptacles, two for new lighting. Price includes wiring for & installing eight new single pole switches for new track lighting & new fluorescent lighting. (Switches to be in wire mold boxes) one 4 gang switch bank on top of another. Price includes re -wiring one existing 220v. receptacle, to 120v. Price includes two new floor receptacles with "Brass" covers. Price includes all lighting specifications. Exclusions: - All permits and inspection fees - Pace Electrical Contractors, Inc. is not responsible for changes made by authority having jurisdiction. All work performed on this project must be done between normal business hours Monday through Friday. Payment to be made a follows: Upon Completion. PLEASE NOTE THIS PROPOSAL MAY BE WITHDRAWN IS NOT ACCEPTED WITHIN THIRTY DAYS. Work described above to be done for the sum of: FOUR THOUSAND SIX HUNDRED SIXTY FOUR DOLLARS 26/100 ($4,664.26) Thank you, Ricky Lee Pace Electrical Contractors, Inc. Pro o L cctric zeal Contractors, inc. 6606 Abercorn Street Suite 120 Savannah, GA 31405 Office: (912) 352 -7718 Fax: (912) 355 -6197 www.prolectrlc.net Proposal Lighting Improvements Date: January 25, 2013 CIient: Tybee Island Arts Association Thompson Atlantic P.O. Box 1413 Tybee Island, GA 31328 Samantha Claar (President) C: (404) 966 -3647 E; samanthaclaar()bellsouth.net Tommy Thompson (Member) — C: (912) 655-0234 E: thomasfstop @gmail.com GENERAL: This proposal is for the electrical work described in the "Scope of Work" below. SCOPE OF WORK: 1. Provide for separate switching for each new light track and two separate switches for the new fluorescent fixtures. The circuit and switch design for the proposed improvements shall be the responsibility of the Contractor. Meet with an authorized TAA representative to finalize the location of all improvements. 2. Lighting improvements specifications & description: (7) Track sections: Lightolier - 6008NWH (35) Fixtures: Lightolier - 9021WH (35) Lamps: EcoSmart or equal 14 -watt R2o CFL 3500K (9) Fluorescent fixtures: Lithonia 2SB 4 32 120170L GEBioIS (36) Fluorescent lamps: Phillips or equal 32W T8 Neutral 3500K (2) Recessed floor outlets: Wiremold /Legrand 862DB w /895TAL OR 895T receptacle and cover. (14) New wall outlets & covers: Leviton or equal M22- CBR15 -WMP 14 & wall outlet covers: Leviton or equal R62- ooPJ8 -0OW 3. The location of all outlets will be determined on site by the Contractor and the authorized TAA representative. TOTAL PRICE: $8,731 • All information, including prices, is confidential. • Pricing is subject to change in the event of changes in Scope of Work. Pricing is good for 30 days from date of this proposal. Respectfully Submitted, Mike Early President Proi Lectric let trical M. 660 ABERCORN ST, STE, 120 SAV/ NAN, GA 31405 Thompson Atlantic PO Box 1413 Tybee Island, GA 31328 @ec-112-ica( Con,--6c4-0 (T-tt -51Seu,4-kern -151u OCflRCtI (G 3Nos Ion/ipso() -A-Han't-ic RO. 13a, tql3 [ybee. -fsbuilA (P313 POsp, ,c.ve a f lu 5 kw,,•—•11;, P1311\10(WWE7 $00a:45° '1.30011065337 JAN 25 2013 MA LED FROM ZIP COD1:•3 405 otsposi. „sk 4Q et P , mitamess a • „asks .= PITNEY BOWES 02 1P $ 000.45° 0001756591 JAN 25 2013 MAILED FROM ZIP CODE 31405 ib 11 I h m :Ili ,1[. "An Approved Set of PI ns Must Remain on Job Site at II Times" REVIEW FOR CODE COMPLIANCE Every effort has been made to identify code violations, no oversight by the reviewer shall be construed as authority to violate, cancel, alter or set aside any applicable codes or ordinances. The review and permit should not be construed RevIiwdrJ4 Dat 11■111111111■1111.111111■11i r === Eie6tvicai inJtelintiore must comply with The National Electric Code.,2ALL_Edition and State OSAVOSI Anlendn'ae,- ■ A r 9. 1 rt 4 r • new 8ft . Lightolier Tracks m existing 4ft. Light Tracks Uthonia fluorescent fixtures 4 1--&olgra45 fe Yhc..ck + IFOI.1011.01•1001.1.14 unted on ceiDing 1'6" offvaHs C ey k c bile( at,E- 1OGN. e, jr-el nrornmel Tybee Arts Assc schematic Iightii scale: 1/4" = 1/18/201: