HomeMy Public PortalAbout10-0556 Fire Suppressionslawk
INTERNATIONAL
CODE COUNCIL'
City oi .. bee Island • Community Develo,__ ent Dept.
Inspection Report
403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328
Phone 912.786.4573 ext. 114 • Fax 912.786.9539
Permit No.
Owner's Name
QS-0
Gen. Contractor
MEMBER
Date Requested
Date Needed
A-Bc. Subcontractor
Contact Information JG� �f �- e e_, 2g2- 155 314
Project Address ) —Ili- to r sc,
re Su pPres -S or
Scope of Work .
Inspector
(17/4)-tei4.-,-)
Date of Inspection //! -3 /P'0
Inspection Pass • ( Fee
Inspection Pass ❑ Fail ❑ Fee
Inspection Pass Fail Fee
Inspection Pass ❑ Fail ❑ Fee
DATE ISSUED: 11 -24 -2010
WORK DESCRIPTION
WORK LOCATION
OWNER NAME
ADDRESS
CITY, ST, ZIP
PHONE NUMBER
CONTRACTOR NAME
ADDRESS
CITY STATE ZIP
FLOOD ZONE
BUILDING VALUATION
SQUARE FOOTAGE
OCCUPANCY TYPE
TOTAL FEES CHARGED
PROPERTY IDENTIFICATION #
PROJECT VALUATION
CITY OF TYBEE ISLAND
BUILDING PERMIT
MECHANICAL - FIRE SUPPRESSION
13 TYBRISA ST
BERNIE'S TYBEE ISLAND INC
PO BOX 1411
SAVANNAH GA 31402
912- 786 -5100
ABC FIRE EQUIPMENT
206 ISABELLA ST
WAYCROSS GA 31501
P
$ 45.00
$2,500.00
PERMIT #: 100556
TOTAL BALANCE DUE: $ 45.00
It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire,
soil and sedimentation, wetlands, marshlands protection and shore protection ordinances and codes whether local, state or federal, including
all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be
approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction
covered by this permit.
This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted
work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided
unless work has begun within six months of the date of issuance.
Signature of Building Inspector or Authorized Agent:
P. O. Box 2749 - 403 Butler Avenue, Tybee Island, Georgia 31328
(912) 786 -4573 - FAX (912) 786 -9539
www.cityoftybee.org
11/23/2010 10:15 9122850797
ABCFIRE PAGE 01
CITY OF TYBEE ISLAND
COMMUNITY DEVELOPMENT DEPARTMENT
P.O. Box 2749 •403 Butler Ave., Tybee Island, GA 31328
Phone (912) 786 -4573 Fax (912) 786 -9539
MECHANICAL PERMIT APPLICATION
Location of work (street address) e PjV /CS 7;9y3t--4 340.v.2 13 Te,gfpf
Contractor c C,41 r✓rl r 6-0
Address of contractor 2O , 5 eaa , "1: & - 3/30 /
?%_45:31
Contact name & telephone number of contractor
Name of property owner 17g t - 476-C
Mailing address of property owner A ‘0.( ,'I /yea i1iley
Telephone number of property owner Y(2- 7f6- 5I0o 9l - 7- eZy.
Residential Commercial ✓
New Work Replacement
Details of project Xr✓5j�v6( 6efe ,SeilgzSSr- Pen ,'iJ /love)-
` Sf S?bri I S _Joo d! G✓?r v, Q)
Estimated cost of construction 411S-00 .'
Date work will be ready for inspection, if known
ATTENTION:
Permit Number
10-0 '.54,0
Inspections for Mechanical Permits are required and will be in accordance with the
International Residential Code or the International Mechanical Code and the Georgia
Amendments.
Requirements for "chauee -juts" tvi.11 not be less than the requirements for new Installations. In
addition, elevation of outside condensing units for FEMA compliance is required. Plan
accordingly. Please ask if you have any questions.
ontractor signature
)4y/4 4:'
//-/F- ZD /O
Date
Owner /Contract printed name
—� 1 ,� 44 4 / iU
L i�tr
NOV -23 -2010 09 :28
9122850797 96% P.01
11/23/2610 10:15 9122850797 ABCFIRE PAGE 62
X0(0
CHAPTER I
GENERAL INFORMATION
Chapter 1 — General Information
INTRODUCTION
The Protex Series II Restaurant Fire Suppression System is of the pre - engineered type as defined by NFPA -17A Standard for
Wet Chemical Extinguishing Systems and is designed to provide fire protection for restaurant cooking appliances, hoods, and
ducts. Installation and maintenance of the system must conform to the limitations detailed in this manual and be performed only
by, an Authorized Protex Series II dealer.
The Protex Series II System utilizes a wet chemical agent specifically designed to suppress restaurant cooking area fires. The
system provides automatic actuation and can be manually actuated through a remote mechanical pull station. Upon actuation, the
system discharges a pre - determined amount of agent to the duct, plenum, and cooking appliances. The agent acts to suppress
fires in three ways:
1. The chemical chain reaction causing combustion is interrupted by both the agent Itself and the resulting.,stearn formation.
2. The agent cools the fire bringing It below auto- ignition temperature.
3. The agent reacts with hot grease forming a soap -like layer (saponification) that helps prevenethe'escape of combustible
vapors, thus preventing re- ignition.
The shutdown of fuel and power to all appliances under protected ventilation equipment is required upon system`aituation. The
shutdown of make -up or supply air is recommended upon system actuation but is not required, Exhaust tans) in the ventilation
system should remain on during system discharge as they assist the dispersion of chemical through the Ventilating system. The
system is UL Listed with or without exhaust fan shutdown,
TEMPERATURE LIMITATIONS
The operating temperature range of the Protex Series II System is 32° F. (0° C_) minimum to 120' F. (49' C.) maximum.
UL LISTING
The Protex Series ii Restaurant Fire Suppression System has been tested to the UL Standard for Fire Extinguishing Systems For
Protection of Restaurant Cooking Areas, UL300 and Listed by Underwriters Laboratories, inc. System agent cylinders bearing
the Underwriters Laboratories of Canada, Inc. ULC mark also meet Underwriters Laboratories of Canada's Standard ULC /ORD-
C 1254.8- 1995.
4
UL XXIXX January 15, 2002
NOU -23 -2010 09 :29 9122850797
1 Part a PMAN2 rev 0 '
9G% P.02