Loading...
HomeMy Public PortalAboutEIGHTH PL_14I ITERN!J ] I „L CODE COUNCIL MEMBER Permit No. City of Tybee Island • Community Development Dept. Inspection Report 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328 Phone 912.472 -5032 • Fax 912.786.9539 /2'1 ,% � Date Requested i Owner's Name / -1/4;7/.4.77,1 Date Needed Gen. Contractor t--' : 1, G� Subcontractor Contact Information c%r '`,Z--)' 2 G Project Address '• '' r //,-i ; %-v r%-'� Scope of Work %= )A2-2 f - _'- • Inspector Date of Inspection ---` Inspection /-%) /---/13.41 — Pass Fail El Fee Inspection Pass ❑ Fail ❑ Fee Inspection Pass ❑ Fail ❑ Fee Inspection Pass ❑ Fail ❑ Fee CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 02 -5 -2013 PERMIT #: 130078 WORK DESCRIPTION REPAIR PIERS/METAL STRAPS WORK LOCATION 14 EIGHTH PLACE — PIN #4- 0006 -02 -006 OWNER NAME JOHN HIGHAM ADDRESS 119 ROGERS AVE CITY, ST, ZIP SOMERVILLE MA 02144 -2208 PHONE NUMBER CONTRACTOR NAME FIRST CITY ENTERPRISES ADDRESS PO BOX 1016 CITY STATE ZIP TYBEE ISLAND GA 31328 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 85.00 PROPERTY IDENTIFICATION # PROJECT VALUATION $5,000.00 TOTAL BALANCE DUE: $ 85.00 It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire, soil and sedimentation, wetlands, marshlands protection and shore protection ordinances and codes whether local, state or federal, including all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: P. 0. Box 2749 - 403 Butler Avenue, Tybee Island, Georgia 31328 (912) 786 -4573 - FAX (912) 786 -9539 www.cityoftybee.org 13 -0078 \ \; Property Address: %y ?ft' Plrc2. City of Tybee Island, Georgia 912 - 472 -5033 or 912 - 472 -5031 - Fax 912- 786 -9539 APPLICATION FOR BUILDING PERMIT -oaf (Check all that apply) igt Single Family CZI Discovery /Tearout ❑ Duplex ❑ Footprint Changes — ID Multi- Family units new square feet ❑ Commercial units �-�,' /heated /cooled '} Details of Project: A -to ' €j2�p ( f tk cncf & %!itf�./ %S or r4 \ Aits/I) ctiafc OultriJect h4a, offy Artiejv cl/! A W 7 lukj s A) /6YE. ax o4..►5) Estimated Cost of Construction: $ 5 O0 V . 0 0 (materials + labor + profit/overhead) If applicable, attach a copy of the certified elevation certificate and /or survey of the property. Depending upon the scope of the work, two sets of construction drawings and /or a site plan may be required. ❑ Demolition of Structure ❑ Other Year Built: Listed on National Historic Register or located within a National Historic District? Y / N * Buildings older than 50 years may be eligible to be listed on the State / National Register. With this designation, you may be eligible to take advantage of various tax incentive programs while preserving the heritage of Tybee Island. * Also see the Tybee Island Land Development Code Article 14: Historic Preservation During construction: On -site restroo facilities will be provided throug(,!/JUe12— . Construction debris will be disposed by CLW1/211c Dr by means of iPvc;K_ . I understand that I must comply with zoning, flood damage control, building, fire, shore protection and wetland ordinances, FEMA regulations and all applicable codes and regulations. I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way adversely affected as required by Article 16, Stormwater Management. I accept responsibility for any corrective action that may be necessary to restore drainage impaired by this permitted construction. A Date: Signature of Applicant: Printed Name b. Note: A permit normally takes 7 to 10 days to process Approvals: Planning & Zoning Manager Building Official Water /Sewer Storm /Drainage City Manager Signature / At.'" Date a FEES res; ►en44..! Permit Inspections Cap Cost Rec Water Tap Sewer Stub Eng. Fees Aid to Const. TOTAL Name Mailing Address Telephone Owner Architect or Engineer ,I JCL N (, f, f,/ � S -MA, y- }N/(6/ -0 l e l,r5.01, Home: Cell: Pt,�.0 Ig_4,-S/1�SS11 1)t i ,,00,��� p.0 .84 ( 6.1.97 c(), itit idC a* �, cS �6 -8—z. -CS Contractor fig,' (� `,,,� f J12 CT) gdkr i`" J j� Office: 6- 521D Cell: So 7`8'6 , p a gct. i 61 i T),„ ., CA (Check all that apply) igt Single Family CZI Discovery /Tearout ❑ Duplex ❑ Footprint Changes — ID Multi- Family units new square feet ❑ Commercial units �-�,' /heated /cooled '} Details of Project: A -to ' €j2�p ( f tk cncf & %!itf�./ %S or r4 \ Aits/I) ctiafc OultriJect h4a, offy Artiejv cl/! A W 7 lukj s A) /6YE. ax o4..►5) Estimated Cost of Construction: $ 5 O0 V . 0 0 (materials + labor + profit/overhead) If applicable, attach a copy of the certified elevation certificate and /or survey of the property. Depending upon the scope of the work, two sets of construction drawings and /or a site plan may be required. ❑ Demolition of Structure ❑ Other Year Built: Listed on National Historic Register or located within a National Historic District? Y / N * Buildings older than 50 years may be eligible to be listed on the State / National Register. With this designation, you may be eligible to take advantage of various tax incentive programs while preserving the heritage of Tybee Island. * Also see the Tybee Island Land Development Code Article 14: Historic Preservation During construction: On -site restroo facilities will be provided throug(,!/JUe12— . Construction debris will be disposed by CLW1/211c Dr by means of iPvc;K_ . I understand that I must comply with zoning, flood damage control, building, fire, shore protection and wetland ordinances, FEMA regulations and all applicable codes and regulations. I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way adversely affected as required by Article 16, Stormwater Management. I accept responsibility for any corrective action that may be necessary to restore drainage impaired by this permitted construction. A Date: Signature of Applicant: Printed Name b. Note: A permit normally takes 7 to 10 days to process Approvals: Planning & Zoning Manager Building Official Water /Sewer Storm /Drainage City Manager Signature / At.'" Date a FEES res; ►en44..! Permit Inspections Cap Cost Rec Water Tap Sewer Stub Eng. Fees Aid to Const. TOTAL LEAD -BASED PAINT RRP RULES Ordinary renovation and maintenance activities can create dust that contains lead. Contractors who perform renovation, repairs, and painting jobs in pre -1978 housing and child- occupied facilities must, before beginning work, provide owners, tenants, and child -care facilities with a copy of EPA's lead hazard information pamphlet Renovate Right: Important Lead Hazard information for Families, Child Care Providers, and Schools. Contractors must document compliance with this requirement. After April 22, 2010, federal law will require you to be certified and to use lead -safe work practices. Georgia Environmental Protection Division Lead -Based Paint and Asbestos Program (404) 363 -7026. Projects must be done by a Certified Lead Renovation Firm AND a Certified Renovator When disturbing lead -based painted or coated surfaces or components more than 6 ft2 per interior room or 20 ft2 of exterior surfaces AND all window replacements and partial demolitions of any size. * * * * * * * * * * * * * * * * * * * ** Asbestos /Environmental Notification to Georgia EPD for Projects Involving Demolition, Wrecking, or Renovation The undersigned hereby acknowledges that the issuance of this permit does not in any way grant permission to the owner, owner's representative, or permit holder to proceed with demolition, wrecking, or renovation of a structure prior to the filing of any required ten (10) day "Project Notification for Asbestos Renovation Encapsulation or Demolition" form in accordance with the Georgia Asbestos Rules. The Georgia Environmental Protection Division administers the rules. In most cases, the rules require both the owner and the involved contractors to assure the portion of the building involved in the project is thoroughly inspected by an Accredited Asbestos Inspector for materials that contain asbestos; and the removal of the asbestos before renovation, wrecking, or demolition begins almost without exemption. Georgia EPD requires a completed demolition notification from be submitted 10 workings days in advance even if no asbestos is present in the building. Further guidance for regulatory compliance and contact telephone numbers are provided by the brochures entitled Asbestos & Renovation and Asbestos and Demolition. Other environmental issues such as asbestos removal techniques, lead abatement, ground contamination, or unusual site conditions may have EPD regulations that could affect the project. * * * * * * * * * * * * * * * * * * * ** BMPs While BMP deficiencies are not necessarily the fault of the owner or his agent, BMPs are their responsibility. Two areas of deficiencies are in the most basic and common BMPs; Co — Construction Exit and Sd1 — Sediment Barrier. Correct installation information can be found in the Field Manual for Erosion and Sediment Control in Georgia, Fourth Edition 2002, Georgia Soil and Water Conservation Commission; http:// www. gaswcc .org /docs /field_manual_4ed.pdf. Problems with the Co is not limited to the installation, but to material. The stone will be a representation of 1.5 " -3.5" stone or larger. Type A sediment barriers have been installed where Type C is required and shown on the permit drawings. Where two rows are called for they will be installed with a separation that allows for the first one to fail (fall over) without impacting the second one. The complete assembly and installation must be compliant; steel or west sts, post spacing, Ty e Cfor A. CDT, a/) Signature for re ipt of L,ad gain , Asbestos, and BMP notices. Date 1/1 tkAk\- ,..1. Printed Name W. Hunter Saussy III, P.C. 400E Johnny Mercer Boulevard P.O. Box 30597 Savannah, Georgia 31410 'x: Hunter Saussy, III, P.C. October 2, 2012 First City Enterprises P.O. Box 1016 Tybee Island, GA 31328 Attn: Tom Beytagh Re: Review of Concrete Piers at 14 8th Terrace St Tybee Island, GA Project No. 12116 Dear Tom: Phone: (912) 898 -8255 Fax: (912) 898 -1882 Email: \\ 1 l 1111 \A\ iNCSo C! )NlC:;s', .NE-1 Page 1 of 1 It was a pleasure meeting you this afternoon to review the condition of the existing concrete piers at the carport area on the above referenced project. Based on our observations, it appears that seven of the concrete piers and their subsequent connections between the piers and the timber posts over, must be retrofitted. On five of the piers, a new steel strap anchorage should be installed per Attachment SK -1. On two of the piers, the existing concrete piers are severely cracked and should be encased with a new steel strap anchorage (see SK -1) included per Attachment SK -2. If there are any questions, please do not hesitate to contact me. Yours truly, W. Hunter Saussy III, P.E. WHS /rlm C;\ Robin\ WPWIMLetters\2012 \120ct02_12116 Tom Bevtagh.x•pd \01 1,1131 'tut's% STRUCTURAL ENGINEER "An Ap rot•::-' .t :31` Rana Must Remain :•1 ..�-. ;. :: at M Tim ... )1% 0 Aa war ui c o oa as Ire etc P. avo r • •• a aa, 0 PS H DCI CORROSION Ota °aZ N IBITOR W *"4 0-12 c L soc a3 all v .o v m LC es c Jo c ts— pso —ssia ▪ ag0n Wo�masa to at 0 CL �p ai a v Q gm o a- ® w 1- U4 WI ta CP CC Z CC M W F = Q co • Z c) CO Ca'aUS CC t au a w q 3 et trc . w Lt. .4 SKETCH 1 1/2" CHAMFER 4 CORNERS EXISTING TIMBER POST X I CONCRETE PIER E NOTE: ALL REINFORCING SHALL BE GALVANIZED MAW N'JW 1r NOW" ► 11 3 TIES ® 6" o.c. 8 #4 DOWELS SET IN 4" DEEP DRILLED HOLES FILLED W/ EPDXY ADHESIVE REMOVE SLAB EACH SIDE AS REQ'D. TO IN TALL CONCRETE V CONCRETE PIER RETROFIT (2 LOCATIONS) nitW. HUNTER SAUSSY, III P.C. 400E JOHNNY MERCER BLVD. P.O. BOX 30597 SAVANNAH, GEORGIA 31410 PHONE: (912) 898 -8255 FAX: (912) 898 -1882 EMAIL: WHSDRAWINGS @COMCAST.NET PLOT DATE: SK2.dwg 10/15/2012 9:34 an SCALE: NA' s. DRWNRY: CHK BY: WHSIII ISSUED BY *HSIII DATE 10 -12 -12 Not Valid Unloss Signed PROJECT: REVIEW OF CONCRETE PIERS AT 14 Sth TERRACE St. CHATHAM CO. TYREEIS., GEORGIA PROJECT NO 1 2 1 1 6 TITLE: CONCRETE PIER RETROFIT (2 LOCATIONS) SK -2 SHEET 2 OF 2 PROVIDE 6 "x6" CONCRETE ENCASEMENT ('IN.) AT ANCHORAGE 4" PROVIDE P.T. PLYWOOD OR SOLID P.T. BLOCKING TO F LL SPACE BETWEEN BACK OF STRAP AND FACE OF TIMBER COLUMN RCN <0 c0 EXISTING TIMBER LU THRU BOLTS EXISTI G 203 S EEL STRAP — HOT DIPPED GALVANIZED © OF TIMBER POST ON ONE SIDE 7" HIGH x 3/8" BEVELED STIFFENERS 3/8" N E X S T G EXISTING SLAB N 1 P R 1"0 HILTI "HAS" ROD SET IN 84" HOLE FILLED W/ HILTI "HVA" ADHESIVE 441 4" v s) 4 EXISTING FOOTING yNT TIMBER POST CONNECTION RETROFIT (SEVEN LOCATIONS) MW. HUNTER SAUSSY, III P.C. 400E JOHNNY MERCER BLVD. P.O. BOX 30597 SAVANNAH, GEORGIA 31410 PHONE: (912) 898 -8255 FAX: (912) 898-1882 EMAIL: WHSDRAWINGS @COMCAST.NET PLOT DATE: SK1.dwg 10/15/2012 9:24 an SCALE PITS. DRWN f3V: Not Valid Tin ees Signed PROJECr: REVIEW OF CONCRETE PIERS AT 14 8th TERRACE St. CHAIHAM CO. TY8EE IS., GEORGIA CHI(SY: WHSIII PROJECT NO 12116 ISSUED BY: WHSIU DATE 10 -12 -12 TITLE: TIMBER POST CONNECTION RETROFIT (SEVEN LOCATIONS) SK -1 SHT I of 2