Loading...
HomeMy Public PortalAbout19th Avenue at Delaware Street Signal Interconnect and Concar Drive at Delaware Street Traffic Signal Modifications, Project No. 09-90-55.34CITY OF SAN MATEO DEPT. OF PUBLIC WORKS PELEASED E0 CONSTRUCTION s4 BURLINGAME VICINITY MAP (NOT TO SCALE) FOSTER CITY BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-642-2444 TOLL FREE 48 -HOURS BEFORE ALL PLANNED WORK OPERATIONS CITY OF SAN MATED SAN MATEO COUNTY, CALIFORNIA CITY PROJECT NO. 09-90-55.34 PLANS FORS 19th/FASHION ISLAND & DELAWARE STREET SIGNAL INTERCONNECT & CONCAR DRIVE ni DELAWARE STREET TRAFFIC SIGNAL MODIFICATIONS TO BE SUPPLEMENTED BY STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD PLANS DATED JULY 1992. INDEX OF SHEETS SHEET NO. DESCRIPTION SHEET 1 OF 4 TITLE SHEET SHEET 2 OF 4 SHEET 3 OF 4 SHEET 4 OF 4 THE CONTRACTOR SHALL POSSESS A CLASS "C-10" LICENSE AT THE TIME THE CONTRACT H AWARDED. GENERAL NOTES 1. ALL SIGNAL WORK SHALL BE DONE IN CONFORMANCE WITH THE LATEST EDITIONS OF THE CITY OF SAN MATEO STANDARD PLANS, CALIFORNIA DEPARTMENT OF TRANSPORTATION (CALTRANS) STANDARD SPECIFICATIONS, STANDARD PLANS (DATED JULY 1992), TRAFFIC MANUAL AND SPECIAL PROVISIONS. FOR SYMBOLS, SEE CALTRANS STANDARD PLANS ES -1A AND ES -1B. APPLICABLE CALTRANS STANDARD PLANS DATED JULY 1992 A -10A A-108 A20 —A A20 —B A20 —C A20 —D A24 —A A24 —B A24 —E ES -1A ES -1B ES -2A ES -2B ES -3A ES -3B ES -3C ES -3D ES -3E ES -4A ES -4B ES -5A ES -5B ES -5C ES -5E ES -6A ES-6AA ES -6L ES -6M ES -6S ES -6T ES -8 ES -10 ES -11 ES -13 ES -14 ES -33 RNSP—A88 NSP—A89 CONCAR DRIVE © DELAWARE STREET TRAFFIC SIGNAL MODIFICATIONS DELAWARE STREET SIGNAL INTERCONNECT PLAN 19TH AVENUE/FASHION ISLAND DRIVE SIGNAL INTERCONNECT PLAN LEGEND: TDC SL -55------55 SD SD TELEPHONE DEMARCATION CABINET STREET LIGHT SANITARY SEWER STORM DRAIN G— --C— GAS WATER E -E ELECTRICAL T T TELEPHONE w— —W— TV---- -TV— TELEVISION LARRY A. PATTERSON P.E. # C33877 EXPIRATION DATE: 06/30/98 CITY ENGINEER DIRECTOR OF PUBLIC WORKS DATE DATE LOCATION MAP (NOT TO SCALE) US 101 S/8 RAMPS 0 STUDY INTERSECTIONS /M, Meyer, Mohaddes Associates, Inc. Traffic Engineering • Transportation Planning One Waters Park Drive, Suite 210 San Mateo, CA 94403 (415) 571-0666 Tel. (415) 571-0669 Fax CITY OF SAN MATEO TITLE SHEET 19TH & DELAWARE SIC AND CONCAR Sc DELAWARE TRAFFIC SIGNAL DESIGNED: ALM DRAWN: PLC CITY 1 DRAWING NO. 15-16 SHEET 1 OF 4 CHECKED: LAP DATE: 12/96 SCALE: NONE PROJECT NO.: J96-019 \J96-019\cad\dela—cov.dwg 9/8/97 PROJECT NOTES (SHEET 2 OF 4): 0 0 ❑5 0 8 INSTALL CITY -SUPPLIED TYPE 820A-4BL CONTROLLER ASSEMBLY ON STREET ARTERIAL MASTER (OSAM 32), & FULLY WIRED TYPE P CABINET. (INCLUDES CITY -SUPPLIED EVP PHASE SELECTOR) REUSE EXISTING TYPE II SERVICE METER INCLUDING PANEL. REMOVE & SALVAGE EXISTING EQUIPMENT. INSTALL CITY SUPPLIED WWV RECEIVER AND ANTENNA PER PROJECT NOTE *8 ON SHEET 4. INSTALL CITY -SUPPLIED TELEPHONE MODEM. SUPPLY & INSTALL NEW INTERNATIONAL TYPE PEDESTRIAN SIGNAL(S). REMOVE & SALVAGE EXISTING SIGNAL(S). REPLACE EXISTING PPB SIGNS WITH INTERNATIONAL TYPE SIGNS. SUPPLY & INSTALL NEW 3X12" (3X300mm) ALL ARROW SIGNAL HEAD AND MOUNTING HARDWARE. REMOVE & SALVAGE EXISTING SIGNAL & MOUNTING HARDWARE. INSTALL CITY SUPPLIED EVP DETECTOR ON SIGNAL MAST ARM (PHASE AND MODEL NUMBER NOTED). ALL EQUIPMENT IS EXISTING UNLESS OTHERWISE NOTED. on SEE SHEET 3 OF 4 FOR DELAWARE STREET SIGNAL INTERCONNECT PLAN. 10 m ALL CONDUCTORS ARE EXISTING UNLESS OTHERWISE NOTED. INSTALL TELEPHONE CONDUIT PER PACIFIC BELL SPECIFICATIONS AND AS SHOWN IN DETAIL C. INSTALL 2" CONDUIT (53C)(TRENCH IN SOIL) AND PULLROPE FROM CONTROLLER CABINET TO PACIFIC BELL MANHOLE, CONDUCTORS TO BE INSTALLED BY PACIFIC BELL. CALL MR. MARK DIAS, PACIFIC BELL AT (415)572-6304, 48 HOURS BEFORE TRENCHING. 04 04 r�— — ICI FIBER AND COAX. UNDERGROUND CABLE (MODEL 722) L 1— 4 1-1 /2"C(41 C)-,--->1.QLC POLE AND EQUIPMENT SCHEDULE 9 LOCATION STANDARD VEH. SIG. MTG. PED SIGNAL MOUNTING PPB 5 LUMINAIRE (WATTS) * SPECIAL REQUIREMENTS • ARROW TYPE SIG. M.A. LUM. MA MAST ARM POLE ©A 1-B TV -2-T SP -1-T 2 — 4 6 © EX. 301(9.1m) 12'(3.7m) MAS SV-1-T SP -1-T 150 4 C PPB POST 2 4 © 1-B TV -2-T SP -1-T 4 6 E© EX. 30'(9.1m) 12'(3.7m) MAS SV-3-TA SP -2-T 6 ^ 150 4 6 F© EX. 301(9.1m) 12'(3.7m) MAS SV-1-T SP -1-T 6 150 4 7 -- © 1-B TV -2-T SP -1-T 8 — 4 6 ©H EX. 25'(7.6m) 12'(3.7m) MAS SV-1-T SP -1-T 8 — 150 4 7 OTHER REQUIREMENTS ARE COVERED BY NOTES, LEGEND, SPECIAL PROVSIONS AND STANDARD SPECIFICATIONS. FOR TYPE OF STANDARD VEHICLE AND PEDESTRIAN MOUNTING, SEE CALTRANS STANDARD PLANS. BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-642-2444 TOLL FREE 48 —HOURS BEFORE ALL PLANNED WORK OPERATIONS SCALE 1" = 20' (SCALE 1 =240) 0 20' 40' 60' LLJ LIJ F - DELAWARE ❑5 08 ppb CO 9 In S LT 1-1 �J LJ U J C 7 I D %'I, EVB PV THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY 06P 04 W r 6 A 06 Fin LEA 6 >08 103 06 A 0 8 © A06 03 -L L1-0 PV -k1)-- --I- —i -5 04P ci TIT LIJ 06 ppb I LI_Jlll�l; (MODEL 722) ❑7 0 08P '05 V 02 02 & 0 I 02P J CD 0 U' 0 z 0 a PROPOSED lar 0 z n J J w U 0 08 ppb SP ci 04P 04 � hl 1 VARIABLE 2 NOMINAL i zzzizz5//-. CONTROLLER CABINET FOUNDATION 0s7 03 08P 08 03 fl OR 07 04 04P LEGEND: EXISTING EX. E I (N) 08 08P 04 04P 06P 05 I 06 OR Steady Demand Sequence PHASE DIAGRAM 02 I 01 02P 06P 02 06 102P i STREET LIGHT CONDUIT SIGNAL CONDUIT EMERGENCY VEHICLE PREEMPTION (EVP) DETECTOR (MODEL NUMBER NOTED) CONDUCTORS NEW EQUIPMENT PACIFIC BELL TELEPHONE SERVICE POINT SB 389 i 02 ppb g L] 03 1" GRS CONDUIT GROUND CLAMP U. L. APPROVED FOR DIRECT BURIAL INSTALL PULL BOX IN ACCORDANCE WITH CITY OF SAN MATEO SPECIFICATIONS. • BELL END ADAPTORS (TYP.) 2" CONDUIT W/ PULL ROPE 10' X 5/8" COPPER CLAD GROUND ROD GROUND BUSHING DETAIL C NOT TO SCALE OF TRANSPORTATION FOR [L CTRICAL FEATU [A AFFECTINS - ATE FACILITIES y/9J/9 DATE CONDUCTOR SCHEDULE 10 CONDUCTOR DESIGNATION CONDUCTOR NUMBERS RUN NUMBER AAAVAAAAL � oz NO. 14 CONDUCTORS: 01 3 3 6 3 3 3 3 02 6 3 3 3 3 03 3 3 3 04 3 3 6 3 3 05 3 3 6 06 3 3 3 3 07 3 3 3 08 3 6 3 02P 2 2 2 2 2 04P 2 2 4 2 2 06P 2 2 2 08P 2 2 4 02 PPB 1 1 1 1 04 PPB 1 1 2 1 1 1 06 PPB 1 1 1 08 PPB 1 1 2 SPARES 3 3 3 6 3 3 3 3 TOTAL NO. 14 2112 306324 2113 11 N O z NO. 12 CONDUCTORS: PPB COMMON 1 1 1 1 1 1 1 TOTAL NO. 12 1 1 1 1 1 1 1 o 6 z NO. 10 CONDUCTORS: SIGNAL COMMON 1 1 1 1 1 1 1 1 TOTAL NO. 10 1 1 1 1 1 1 1 1 2#12 CONDUCTOR DETECTOR LEAD-IN CABLE (DLC) DETECTOR CABLES: 01 1 1 1 02 1 1 1 1 1 03 1 1 04 1 1 1 05 1 1 1 1 1 06 1 1 1 07 1 1 1 08 1 1 TOTAL DETECTOR CABLES 2 2 4 8 4 2 2 2 OPTICOM CABLE OPTICOM CABLES: CHANNEL "A" + "C" °1 CHANNEL "B" + "D" °1°1 TOTAL OPTICOM CABLES ° 10 c.) <n SIGNAL INTERCONNECT 1 1 1 1 1 TOTAL 1 1 1 1 1 EX. CONDUIT SIZE (INCHES): 21/211/221/231/221/221/211/211/2 2 EX. CONDUIT SIZE (METRIC): 63C41063C90C63C63C41C41C53C NOTE: SEE PLANS FOR WWV ANTENNA CABLE INSTALLATION Ir, I L J 08 L J 08 18" MINIMUM — TO PAC BELL FACILITY (SEE 12 DR/t/E LARRY A. PATTERSON P.E. # C33877 EXPIRATION DATE: 06/30/98 9-8-97 DATE MMeyer, Mohaddes Associates, inc. Traffic Engineering • Transportation Planning One Waters Park Drive, Suite 210 San Mateo, CA 94403 (415) 571-0666 Tel. (415) 571-0669 Fax CITY OF SAN MATEO CONCAR DRIVE @ DELAWARE STREET TRAFFIC SIGNAL MODIFICATIONS 19TH 8c DELAWARE SIC AND CONCAR © DELAWARE TRAFFIC SIGNAL DESIGNED: ALM DRAWN: PLC CITY DRAWING NO. 1-15-16 SHEET 2 OF 4 CHECKED: LAP DATE: 12/96 SCALE: 1' =20' PROJECT NO.: J96-019 \j96-019\cad\dela—tsl.dwg 9/8/97 tstA GENERAL NOTES: 1. UNLESS OTHERWISE NOTED, EXISTING CONDUCTORS IN EXISTING CONDUIT SHALL REMAIN. WHERE NEW SIC IS TO BE INSTALLED IN EXISTING SIGNAL CONDUIT, THE CONTRACTOR SHALL FIELD CHECK AND RECORD THE NUMBERS AND SIZES OF EXISTING CONDUCTORS BEFORE START OF WORK. ALL DAMAGED CONDUCTORS SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE. 2. EXISTING SIGNALS SHALL REMAIN OPERATION AT ALL TIMES UNLESS OTHERWISE APPROVED BY THE ENGINEER AND/OR BY CALTRANS. E SAC ' El' S\O"' EXISTING TYPE 820 CONTROLLER IN TYPE P CABINET E BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-642-2444 TOLL FREE 48 -HOURS BEFORE ALL PLANNED WORK OPERATIONS 2"C(53C)(E), SIC(N) PROJECT NOTES (SHEET 3 OF 4): El INSTALL STATE -FURNISHED MODEL 17OE CONTROLLER PER PROJECT NOTE #4 ON SHEET 4 ❑� INSTALL 1 SIC IN EXISTING CONDUIT. ❑5 INSTALL CITY —SUPPLIED MODEL 820A-4BL CONTROLLER ASSEMBLY. REMOVE & SALVAGE EXISTING CONTROLLER. COMPLETE INTERCONNECT WIRING. SEE SHEET 4 OF 4 FOR 19TH AVENUE/FASHION ISLAND DRIVE INTERCONNECT PLAN. SEE SHEET 2 OF 4 FOR CONCAR ® DELAWARE SIGNAL MODIFICATIONS. 2"C(53C)(E), SIC(N) DELAWARE STREET PACIFIC BOULEVARD Q cn Q 0 O re CD cr 2❑ 2"C(53C)(E), SIC(N) 2"C(53C)(E), SIC(N) ❑2 2"C(53C)(E), 251C(1 —E, 1—N EXISTING MODEL 820 CONTROLLER IN TYPE P CABINET THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY ABBREVIATIONS SCC STATE CONTROLLER CABINET SPB STATE PULL BOX l 2 —3"C(78C)(E), 3SIC(2—E, 1—N) 41#14, 15DLC, 2#8, 2#6, 2 COMM.CABLES 3"C(78C)(E), 3SIC(2—E, 1—N) 2"C(53C)(E), 2SIC(E) 2"C(53C)(E), SIC(E) [..1 Cr 0 CC CO 0 50' 100' SCALE 1" = 100' (SCALE 1=1200) I rn Qa cr CO Cr �-'W jO O cr tn N EXISTING MODEL 170 CONTROLLER eO� IN TYPE 332 CABINET SPB 0 2" C(53C)(E), SIC(N) DELAWARE STREET APPROVED 2"C(53C)(E), SIC(N) CALIFORNIA DEPARTMEtX) OF TRANSPORTATION DATE 177 FOR ELEDTRICAL 'mans •FFECTINS£ ATE FACILITIES LARRY A. PATTERSON P.E. # C33877 EXPIRATION DATE: 06/30/98 AA, Meyer, Mohaddes Associates, inc. Traffic Engineering • Transportation Planning One Waters Park Drive, Suite 210 San Mateo, CA 94403 (415) 571-0666 Tel. (415) 571-0669 Fax CITY OF SAN MATEO DELAWARE STREET SIGNAL INTERCONNECT PLAN 19TH & DELAWARE SIC AND CONCAR © DELAWARE TRAFFIC SIGNAL DESIGNED: DRAWN: CHECKED: ALM PLC LAP CITY NO. 1-15-16 SHEET DRA 3 OF 4 DATE: 12/96 SCALE: 1'1=100' PROJECT NO.: J96-019 \j96-019\cod \dela—ic 1.dwg 9/8/97 GENERAL NOTES: UNLESS OTHERWISE NOTED, EXISTING CONDUCTORS IN EXISTING CONDUIT SHALL REMAIN. WHERE NEW SIC IS TO BE INSTALLED IN EXISTING SIGNAL CONDUIT, THE CONTRACTOR SHALL FIELD CHECK AND RECORD THE NUMBERS AND SIZES OF EXISTING CONDUCTORS BEFORE START OF WORK. ALL DAMAGED CONDUCTORS SHALL BE REPLACED BY THE CONTRACTOR AT HIS OWN EXPENSE. 2. EXISTING SIGNALS SHALL REMAIN OPERATION AT ALL TIMES UNLESS OTHERWISE APPROVED BY THE ENGINEER AND/OR BY CALTRANS. 3. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING FIELD DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL FOR WWV ANTENNA INSTALLATION. CONTRACTOR MAY PROVIDE AN ALTERNATE ANTENNA MOUNTING DETAIL AFTER APPROVAL BY ENGINEER. EXISTING III —AF XIST NG EQUIPMENT ITEMS01 EQUIPMENT ENCLOSURE 11502 THROUGH ®© © THROUGH © AND 0 THROUGH ©PER SERVICE WIRING DIAGRAM ON ES -2D (STANDARD PLANS). SI?92 orr EXISTING MODEL 170 CONTROLLER IN TYPE 332 CABINET t EXIST. TDC EXISTING SERVICE POINT STATE SYSTEM 35-092-11502 (120/240V) PG&E EXISTING LOAD: 3-200W HPS LUMINAIRES 2500 WATTS — TRAFFIC SIGNAL SYSTEM WWV ANTENNA BNC CONNECTORS WWV RECEIVER N N El T SCCI PROJECT NOTES (SHEET 4 OF 4): ❑� ❑5 INSTALL WWV RECEIVER IN EXISTING CONTROLLER AS PER DETAIL A AND MANUFACTURER'S SPECIFICATIONS. COMPLETE INTERCONNECT WIRING INCLUDING 2 PAIRS FOR STATE TRAFFIC SIGNALS DIRECT INTERCONNECT. SEE DETAIL B ON THIS SHEET. INSTALL 1 SIC IN EXISTING CONDUIT. SEE SHEET 3 OF 4 FOR DELAWARE STREET INTERCONNECT PLAN. ABBREVIATIONS SCC SPB TDC E — STATE CONTROLLER CABINET STATE PULL BOX TELEPHONE DEMARCATION CABINET EXISTING INSTALL STATE —FURNISHED MODEL 170E CONTROLLER ASSEMBLY WITH TWO MODEL 400 MODEMS AS DIRECTED BY CALTRANS, DISTRICT 4. INSTALL WWV RECEVIER AND MAKE ALL CONNECTIONS PER MANUFACTURER'S SPECIFICATIONS. COMPLETE INTERCONNECT WIRING AS DIRECTED BY CALTRANS, DISTRICT 4. EXISTING TRAFFIC SIGNAL CONTROLLER TO REMAIN. SEE DETAIL A. INSTALL WWV ANTENNA ON EXISTING SIGNAL POLE, AT A MINIMUM HEIGHT OF 3011(9 M). ROUTE WIRES THROUGH EXISTING POLE AND CONDUIT, AND CONNECT TO WWV RECEIVER IN SIGNAL CABINET. SEE DETAIL C FOR TYPICAL MOUNTING DETAIL. INSTALL 2" (53C) (TRENCH IN SOIL), 6 PAIR OUTDOOR SERIAL CABLE FROM TDC TO CONTROLLER CABINET. TERMINATE CABLE TO DB25 INSIDE THE CONTROLLER CABINET AND TDC. 2-3"C(78C)(E), 3SIC(2—E,1—N) 41#14, 15 DLC, 2#8, 2#6 2 COMM. CABLES 3"C(78C)(E), 3SIC(2—E,1—N) SR92 ON -RAMP 2"C(53C)(E), SIC(E) MES. UNDERGROUND FIBER _EXIST. PACIFIC BELL MANHOLE 2"C(53C)(E), SIC(E) C305 C205 C25 MODEL 170E Li) STATE LOCAL MASTER CONTROLLER ° RS232 ISOLATED INTERFACE 332 CABINET TO CITY TRAFFIC SIGNAL (AB3418 PROTOCOL) C25 MODEL 170(E) STATE TRAFFIC SIGNAL CONTROLLER PAIR OUTDOOR SERIAL CABLE 2"C(53C)(E), 2SIC(E) EXISTING MODEL 870 CONTROLLER IN TYPE 332 CABINET E \ / 2"C(53C)(E) SIC(E) P ISOLATED INTERFACE R5232 DIAL —UP MODEM L J RS232 (UP TO 1000 FEET) 121)1 DETAIL A (TYPICAL) NOT TO SCALE PAIR ASSIGNMENT 1 STATE 2 CITY 3 INTER —AGENCY 4 INTER —AGENCY 5 CITY 6 STATE PAIR ASSIGNMENT 1 STATE 2 RESERVED 3 RESERVED 4 RESERVED 5 RESERVED 6 STATE CITY SIC (FIRST 6 PAIRS) DETAIL B (TYPICAL) STATE SIC THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY 2"C(53C)(E), SIC(E) 0 0 O 1919 AVENUE 2"C(53C)(E), SIC(E) TRAFFIC SIGNAL POLE SIGNAL POLE 2"C(53C)(E), SIC(E) 0 0 0 r CL OF POLE 1/4"(6mm) 0 BOLT TOTAL 2 BOLT HEAD MOUNT 1 —1 /2"(38mm) MOUNTING BRACKET STEEL STRAP SECTION C -C NOT TO SCALE 2"C(53C)(E), SIC(E) WWV ANTENNA YMCA 4 Dl BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-642-2444 TOLL FREE 48 —HOURS BEFORE ALL PLANNED WORK OPERATIONS 1/4 of cts \ i SCC 2"C(53C)(E), SIC(E) 19TH AVENUE FASHION ISLAND DRIVE SPB s s� 1 ‘74A EXISTING MODEL 170 CONTROLLER EXISTING MODEL 870 CONTROLLER IN TYPE 332 CABINET \SEE ANTENNA MOUNTING DETAIL DETAIL C (TYPICAL) NOT TO SCALE C IN TYPE 332 CABINET C a RISER WWV ANTENNA DETAIL D - ANTENNA MOUNTING DETAIL NOT TO SCALE IA DEPA TMEN OF TRANSPORTATION roc_ 6� 'a ( 44L,/<%1 ION ELytTRICAL RATYIl1I AIfICTIMI I PAClu Tin DATE 0 50' 100' SCALE 1 ®0' (SCALE 1=1200) LARRY A. PATTERSON P.E. # C33877 EXPIRATION DATE: 06/30/98 9-8-97 DATE /& Meyer, Mohaddes Associates, Inc. Traffic Engineering • Transportation Planning One Waters Park Drive, Suite 210 San Mateo, CA 94403 (415) 571-0666 Tel. (415) 571-0669 Fax CITY OF SAN MATEO 19TH AVENUE / FASHION ISLAND DRIVE SIGNAL INTERCONNECT PLAN 19TH & DELAWARE SIC AND CONCAR © DELAWARE TRAFFIC SIGNAL DESIGNED: DRAWN: CHECKED: ALM PLC LAP CITY DRAWING NO. 1 - 1 5- 1 6 SHEET 4 OF 4 DATE: 12/96 SCALE: NONE PROJECT NO.: J96-019 \j96-019\cad \dela—ic2.dwg 9/8/97 W O sit* BURLINGAME VICINITY MAP (NOT TO SCALE) FOSTER 9 CITY K 4) - THE CONTRACTOR SHALL POSSESS A CLASS "C-10" LICENSE AT THE TIME THE CONTRACT IS AWARDED. BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-227-2600 TOLL FREE 48 -HOURS BEFORE ALL PLANNED WORK OPERATIONS CITY OF SAN MATED SAN MATEO COUNTY, CALIFORNIA CITY PROJECT NO. 09-90-55.34 FEDERAL AID NO. CML 5102 (008) PLANS FOR: 19th AVE./FASHION ISLAND BLVD. & DELAWARE ST. SIGNAL INTERCONNECT TO BE SUPPLEMENTED BY STATE OF CALIFORNIA DEPARTMENT OF TRANSPORTATION STANDARD PLANS DATED JULY 1999. INDEX OF SHEETS SHEET NO. SHEET 1 OF 3 SHEET 2 OF 3 SHEET 3 OF 3 GENERAL NOTES DESCRIPTION TITLE SHEET DELAWARE ST. SIGNAL INTERCONNECT PLAN 19th/FASHION ISLAND SIC PLAN 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITIONS OF THE CITY OF SAN MATEO STANDARD PLANS, THE STATE DEPARTMENT OF TRANSPORTATION (CALTRANS) STANDARD PLANS (JULY 1999), STANDARD SPECIFICATIONS (JULY 1999), TRAFFIC MANUAL, AND THE SPECIAL PROVISIONS. 2. ALL UNDERGROUND SIGNAL INTERCONNECT CABLE (SIC) SHALL CONSIST OF NO. 19 OR NO. 20, AWG STRANDED OR SOLID BARE COPPER CONDUCTORS. EACH CONDUCTOR SHALL BE INSULATED WITH 0.013 INCH, MINIMUM, NOMINAL THICKNESS, COLOR CODED, POLYPROPYLENE MATERIAL. CONDUCTORS SHALL BE IN TWISTED PAIRS. COLOR CODING SHALL DISTINGUISH EACH PAIR. THE TWISTED PAIRS SHALL BE WRAPPED WITH AN ALUMINUM POLYESTER SHIELD AND SHALL HAVE A NO. 22 OR LARGER, STRANDED, TINNED COPPER DRAIN WIRE INSIDE THE SHIELDED PAIRS. THE UNDERGROUND SIGNAL INTERCONNECT CABLE JACKET SHALL BE BLACK, HIGH DENSITY POLYETHYLENE, RATED FOR MINIMUM OF 600 VOLTS AND 60 DEGREES C, AND SHALL HAVE A NOMINAL WALL THICKNESS OF 60 MILS, MINIMUM. THE CABLE JACKET OF THE MOISTURE RESISTANT TAPE DIRECTLY UNDER THE OUTER JACKET SHALL BE MARKED WITH THE MANUFACTURER'S NAME, INSULATION TYPE DESIGNATION, NUMBER OF CONDUCTORS AND CONDUCTOR SIZE, AND VOLTAGE AND TEMPERATURE RATINGS. 3. AT LEAST SIX FEET (6') OF SLACK SHALL BE PROVIDED AT EACH CONTROLLER CABINET. THE WIRE BUNDLE ENTERING THE CONTROLLER CABINET SHALL BE COILED IN THE BOTTOM OF THE CABINET IN ORDER TO OBTAIN AS MUCH SLACK AS POSSIBLE. THREE FEET (3') OF SLACK SHALL BE PROVIDED AT ALL OTHER PULL BOXES. 4. ALL INTERCONNECT CABLE SHALL RUN CONTINUOUSLY WITHOUT SPLICES FROM A TERMINAL BLOCK LOCATED IN EACH CONTROLLER CABINET TO A SIMILARLY LOCATED TERMINAL BLOCK. EACH CABLE SHALL BE MARKED AS TO DESTINATION AND DIRECTION IN EACH PULL BOX AND CONTROLLER CABINET. SIC SHALL BE PROVIDED WITH AN OVERALL COPPER SHIELD WHICH SHALL BE GROUNDED AT EACH END. 5. TESTING OF INTERCONNECT CABLE SHALL BE DONE ON EACH INDIVIDUAL WIRE. INSULATION RESISTANCE VALUE SHALL NOT BE LESS THAN 100 MEG OHMS. TESTING SHALL BE DONE BY THE CONTRACTOR IN THE PRESENCE OF THE CITY ENGINEER BEFORE CONNECTING TO THE TERMINAL BLOCK. 6. SIGNAL INTERCONNECT SHALL BE TESTED FOR CONTINUITY AT ALL INTERSECTIONS. TESTING SHALL BE DONE BY THE CONTRACTOR IN THE PRESENCE OF THE CITY ENGINEER OR HIS DESIGNATED REPRESENTATIVE. 7. SIX -PAIR OUTDOOR SERIAL CABLE SHALL INCLUDE #22 SOLID COPPER CONDUCTORS AND SHALL BE RATED FOR FOR DIRECT BURIAL (REA SPECIFICATION PE -39). 8. SALVAGED STATE (CALTRANS) CONTROLLERS SHALL BE DELIVERED TO THE CALTRANS MAINTENANCE YARD AT 30 RICKARD STREET, SAN FRANCISCO (415-330-6500). APPLICABLE CALTRANS STANDARD PLANS DATED JULY 1999 A -10A A -10B ES -1A ES -1B ES -4A ES -48 ES -8 Q PROJECT INTERSECTIONS us 101 S/B RAMPS APPROVED CALIFORNIA DEPARTMENT OF TRANSPORTATION y. No-,. C/17/ FOR ELECTRICAL FEATURES AFFECTING STATE FACILITIES DATE LOCATION MAP (NOT TO SCALE) DESCRIPTION O NO W 0 W W z 5 z W CC 0- 0- U) Z Q Cl_ U SLAND & DELAWARE S 0 U- 0 ‘ W I- LU W W Z ti z W I- H H- LU L�11 cri LJI� H- CALIFORNIA 0 W H- Z Q (/1 SURVEYED BY W a 0 0 z se 0 0 DRAWN BY ACAD DATE 5/02 N 0 if) 0 0 CHECKED BY LU z 0 z W J Q U In PROJECT NO. 09-90-55.34 CASE 1 DRAWER 15 SET 16 SHEET 1 OF 3 \9 7003\502\t itl e9--05/01 /02 AS BUILT w Q C ),- CO GENERAL NOTES: 1. UNLESS OTHERWISE NOTED, EXISTING CONDUCTORS IN EXISTING CONDUIT SHALL REMAIN. WHERE NEW SIC IS TO BE INSTALLED IN EXISTING SIGNAL CONDUIT, THE CONTRACTOR SHALL FIELD CHECK AND RECORD THE NUMBERS AND SIZES OF EXISTING CONDUCTORS BEFORE START OF WORK. ALL DAMAGED CONDUCTORS SHALL BE REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 2. EXISTING SIGNALS SHALL REMAIN OPERATIONAL AT ALL TIMES UNLESS OTHERWISE APPROVED BY THE ENGINEER AND/OR BY CALTRANS. 3. ALL NEW COMMUNICATION PULL BOX COVERS SHALL BE MARKED "INTERCONNECT \'D G 6•e� p�F" \ \ 7 7/ •tG6•e� �/ 7 04/ /, EXISTING TYPE 820 CONTROLLER IN TYPE P CABINET CONNECT 6 -PAIR SIC CABLE. BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-227-2600 TOLL FREE 48 —HOURS BEFORE ALL PLANNED WORK OPERATIONS 2 3 2"C(53C)(EX), ONE 6 -PAIR SIC(N) 2 3 2"C(53C)(EX), .---7 1I0 PR SICTNT tr' EXISTING TYPE 2070 CONTROLLER IN TYPE 332 CABINET TO REMAIN CONNECT 6 -PAIR SIC CABLES. MULTI -PAIR CABLE FROM PREVIOUS CABINET PAIR 1 /Th 3 PAIR 2 PAIR N PROJECT NOTES (SHEET 2 OF 3): 1 1 21 INSTALL CITY -SUPPLIED MODEL 2070 SHELF -MOUNTED CONTROLLER ASSEMBLY IN EXISTING CABINET. REMOVE AND SALVAGE EXISTING CONTROLLER. COMPLETE INTERCONNECT WIRING (SEE DETAIL E). PULL BACK EXISTING 6 -PAIR SIC BETWEEN 25TH AND SARATOGA. INSTALL IN EXISTING CONDUITS ACROSS DELAWARE AND INTO DELAWARE ® SARATOGA CONTROLLER. INSTALL ONE 6 -PAIR SIC IN EXISTING CONDUIT. SEE SHEET 3 OF 3 FOR 19TH AVENUE/FASHION ISLAND DRIVE INTERCONNECT PLAN. COORDINATE SIC INSTALLATION WITH CONTRACTOR CURRENTLY WORKING ON SIGNAL IMPROVEMENTS AT INTERSECTION. 0 1 w -J O m U I i � I U I I � � I om_ 2"C(53C)(EX), ONE 6 -PR 2"C(53C)(EX), & ONE 25 -PR SIC(EX) ONE 25 -PR SIC(EX) > 1 / o I i EXISTING CONDUITS, TWO 25-Pf�2 cc I SIC(EX), TWO 6 -PR SIC(N O CC Q In POLICE STATION 2"C(53C)(EX), ONE 6 -PR & ONE 25 -PR SIC(EX) PAIR 1 3 3 CABLE PAIR TERMINATIONS 1-N (A. SCREW TERMINAL BLOCK PAIR 2 DELAWARE STREET PAIR N 1. INSTALL 25 -PAIR SCREW DOWN TERMINAL BLOCK ON THE INSIDE OF THE SIGNAL CABINET AS SHOWN. TERMINAL BLOCK AND SIC INSTALLATION SHALL NOT INTERFERE WITH ACCESS TO EQUIPMENT OF OPERATION OF THE CABINET. 2. THE TERMINAL BLOCK LOCATION SHALL BE WITHIN THREE FEET (3') OF THE C2 CONNECTOR ON THE BLOCK OF THE MODEL 2070 CONTROLLER. THE C2 CABLE HARNESS TO BE INSTALLED BETWEEN TERMINAL BLOCK AND C2 CONNECTOR IS ONLY THREE FEET (3') LONG. 3. THE TERMINAL BLOCK INSTALLATION AND SIC CABLE ROUTING/TERMINATION SHALL BE CONSISTENT FOR ALL CABINETS. 4. ALL INCOMING AND OUTGOING SIC CABLE SHALL BE INSTALLED WITH APPROPRIATE STRAIN RELIEF AND LABELED USING WIRE TIE STYLE FLAGS. LABELING SHALL INDICATE SOURCE IF INCOMING OR DESTINATION IF OUTGOING. FOR EXAMPLE, FROM PRIMARY ST./SECONDARY ST. OR TO PRIMARY ST./SECONDARY ST. 5. ALL SIC CABLE PAIR TERMINATIONS SHALL BE #8 STUD SPRING SPADE TYPE. 6. SIC CABLE PAIR TERMINATIONS SHALL BE IN THE SAME TERMINAL BLOCK LOCATION FOR ALL CABINETS. FOR EXAMPLE, PAIR ONE (BLUE, BLUE/WHT) SHALL ALWAYS BE ON THE SAME TERMINAL BLOCK LOCATION. 7. CABLE PAIRS SHALL ALWAYS BE TERMINATED ON CONSECUTIVE TERMINAL POSITIONS. 8. EACH TERMINAL SCREW POSITION SHALL BE ABLE TO ACCOMMODATE AT LEAST TWO #8 SPADE LUG CONNECTIONS. MULTI -PAIR CABLE TO NEXT CABINET DETAIL E— SIGNAL INTERCONNECT CABLE TERMINATION DETAIL NOT TO SCALE 0 M 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) 2"C(53C)(EX), TWO 6 -PAIR SIC(EX) EXISTING MODEL 820 CONTROLLER IN TYPE P CABINET ABBREVIATIONS: SIC SCC SPB CPB EX N PR ROW SIGNAL INTERCONNECT CABLE STATE CONTROLLER CABINET STATE PULL BOX CITY PULL BOX EXISTING NEW PAIR APPROXIMATE RIGHT OF WAY LEGEND APPROXIMATE CITY OF RIGHT OF WAY E ___ _ ___ - 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) 1 I I I I I II I I I I I I II I I I I II I I I I I APPROVED CALIFORNIA DEPARTMENT OF TRANSPORTATION \Je r`7%/0 Z ELECTRICAL FEATURES AFFECTING STATE FACIUTIES DATE -C rn I C. / I/ I I I I (/Rf s t,scc SPB a L O W ID Z W Q 4 4 Al -II („Ct I� CPE31 CZ, ml �� T\ at c \P \O) (fin 0 50' 100' SCALE 1"=100' (SCALE 1=1,200) 2'IC(53C)(EX), -_ ON 6_PAIR SIC(N 1' I b3 I )/ / DELAWARE STREET F- (n 3 0O 0 O '2- VON WPC' OM A REROU o WO NV ie 01% ,SOS POLICE STATION EXISTING k. EXISTING DELAWARE STREET 0 100' zoo' SCALE 1"=300' (SCALE 1=3,500) EXISTING GRANT STREET DETAIL F --SIGNAL INTERCONNECT CIRCUIT SCALE: 1 "=300' TYPE 2070 CONTROLLER IN TYPE 332 CABINET TO BE INSTALLED BY OTHERS. 2 C(53C)(EX), ONE 6 -PAIR SIC(N) 3 5 \ 2" CONDUIT 15 i x \ AS BUILTS DESCRIPTION z 0 (no jz re "tw 0 SLAND & DELAWARE S Q a_ INTERCONNECT CD C/1 4 (N w Q 0 PUBLIC WORK L. 0 CALIFORNIA SURVEYED BY BOOK NO. DRAWN BY ACAD DATE 5/02 CHECKED BY AS NOTED PROJECT NO. 09-90-55.34 CASE 1 DRAWER 15 SET 16 NOTE: T IS PLAN IS ACCURATE FOR ELECTRICAL WORK ONLY. SHEET 2 OF 3 \97003\502\dware9--05/01/02 AS BUILT GENERAL NOTES: 1. UNLESS OTHERWISE NOTED, EXISTING CONDUCTORS IN EXISTING CONDUIT SHALL REMAIN. WHERE NEW SIC IS TO BE INSTALLED IN EXISTING SIGNAL CONDUIT, THE CONTRACTOR SHALL FIELD CHECK AND RECORD THE NUMBERS AND SIZES OF EXISTING CONDUCTORS BEFORE START OF WORK. ALL DAMAGED CONDUCTORS SHALL BE REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S OWN EXPENSE. 2. EXISTING SIGNALS SHALL REMAIN OPERATIONAL AT ALL TIMES UNLESS OTHER- WISE APPROVED BY THE ENGINEER AND/OR BY CALTRANS. 3. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING FIELD DIMENSIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL FOR WWV ANTENNA INSTALLATION. CONTRACTOR MAY PROVIDE AN ALTERNATE ANTENNA MOUNTING DETAIL IF APPROVED BY ENGINEER. 4. ALL NEW COMMUNICATION PULL BOXES SHALL BE MARKED "INTERCONNECT". 19Th AVE FWY EXISTING MODEL 170E CONTROLLER SR IN TYPE 332 CABINET 92 of -K.__ 19Th AVE l SYSTEM NO. 35-092-11592 EXISTING TYPE A SERVICE (120/240V). EXISTING LOAD: 900 Watts of Traffic Signal (120 Volts —Metered) 1-150 Watt HPSV Luminaire (120 Volts—Unmetered) 3-200 Wott HPSV Luminaires (120 Volts—Unmetered) PROPOSED LOAD: 1.200 Watts of Traffic Signal (120 Volts —Metered) 1-150 Watt HPSV Luminaire (120 Volts—Unmetered) 3-200 Watt HPSV Luminaires (120 Volts—Unmetered) spf-}-f/ WWV ANTENNA K BNC CONNECTORS WWV RECEIVER w M (N a 1 11 7 10 SCC 819 PROJECT NOTES (SHEET 3 OF 3): ❑1 ❑2 3 141 INSTALL STATE -FURNISHED MODEL 170E CONTROLLER ASSEMBLY IN EXISTING CABINET. EXISTING CONTROLLER TO REMAIN. SUPPLY AND INSTALL TWO MODEL 400 MODEMS AS DIRECTED BY CALTRANS, DISTRICT 4. COMPLETE INTERCONNECT WIRING AS DIRECTED BY CALTRANS, DISTRICT 4. INSTALL CITY -SUPPLIED WWV RECEIVER AND MAKE ALL CONNECTION PER MANUFACTURER'S SPECIFICATIONS. SEE DETAIL A. INSTALL CITY -SUPPLIED MODEL 2070 RACK -MOUNTED CONTROLLER ASSEMBLY IN EXISTING CABINET. REMOVE AND SALVAGE EXISTING CONTROLLER. COMPLETE INTERCONNECT WIRING INCLUDING TWO PAIRS FOR STATE TRAFFIC SIGNALS DIRECT INTERCONNECT. SEE DETAILS B AND E. INSTALL STATE -FURNISHED MODEL 170E CONTROLLER ASSEMBLY IN EXISTING CABINET. REMOVE AND SALVAGE EXISTING STATE CONTROLLER. COMPLETE INTERCONNECT WIRING INCLUDING TWO PAIRS FOR STATE TRAFFIC SIGNALS DIRECT INTERCONNECT. SEE DETAILS B AND E. INSTALL ONE 6 -PAIR SIC IN EXISTING CONDUIT. I f INSTALL WWV ANTENNA ON EXISTING SIGNAL POLE AT A MINIMUM HEIGHT OF 30'(9 M). I SEE DETAIL C FOR MOUNTING DETAIL. INSTALL WWV CABLE INSIDE SIGNAL POLE. 6 7 INSTALL WWV CABLE IN EXISTING CONDUIT. CONNECT WWV CABLE AND RECEIVER IN CONTROLLER CABINET. INSTALL 2"C (53C) BETWEEN EXISTING PULL BOXES (TRENCH IN SOIL). INSTALL 6 -PAIR OUTDOOR SERIAL CABLE FROM TDC TO CONTROLLER CABINET. TERMINATE OUTDOOR SERIAL CABLE TO DB25 INSIDE THE CONTROLLER CABINET AND TDC. SEE SHEET 2 OF 3 FOR DELAWARE STREET INTERCONNECT PLAN. 2-3"C(78C)(EX), TWO 6 -PR SIC(EX), ONE 6 -PR SIC(N), 1 WWV CABLE(N), 1 COMM. CABLE(EX), 1 COMM. CABLE (N) 41#14(EX), 2#8(EX), 2#6(EX), 15 DLC(EX) 3"C(78C)(EX), ONE 6 -PR SIC(EX), ONE 6 -PR SIC(N), & 1 WWV CABLE (N) ------------ --4 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) L 2"C(53C)(EX), TWO 6 -PAIR SIC(EX) EXISTING MODEL 870 CONTROLLER In IN TYPE 332 CABINET II 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) _ _ C305 C205 C25 N MODEL 170E STATE LOCAL MASTER CONTROLLER ° RS232 ISOLATED INTERFACE 332 CABINET TO CITY TRAFFIC SIGNAL (AB 3418 PROTOCOL) C25 MODEL 170(E) STATE TRAFFIC SIGNAL CONTROLLER PAIR OUTDOOR SERIAL CABLE P ISOLATED INTERFACE RS232 DIAL -UP MODEM GRANT STREET L J RS232 (UP TO 1000 FEET) TDC DETAIL A (TYPICAL) NOT TO SCALE PAIR ASSIGNMENT 1 STATE 2 CITY 3 INTER -AGENCY 4 INTER -AGENCY 5 CITY 6 STATE CITY SIC (FIRST 6 PAIRS) DETAIL B (TYPICAL) NOTE: THIS PLA\ ABBREVIATIONS SIC SIGNAL INTERCONNECT CABLE SCC STATE CONTROLLER CABINET SPB STATE PULL BOX CPB CITY PULL BOX TDC TELEPHONE DEMARCATION CABINET EX EXISTING N NEW PR PAIR BNC BAYONET NUT CONNECTOR SIGNAL POLE B STREET APPROXIMATE RIGHT OF WAY LEGEND APPROXIMATE CITY OF RIGHT OF WAY 0 50' 100' SCALE 1"=100' (SCALE 1=1,200) 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) 19th AVENUE 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) O O O 2"C(53C)(EX), ONE 6 -PAIR SIC(EX) aa- 2"C(53C)(EX), TRAFFIC SIGNAL POLE O O O r DETAIL C (TYPICAL) NOT TO SCALE IS ACCURATE FOR ELECTRICAL WORK ONLY. YMCA t k TWO 6 -PAIR SIC(EX) Ct OF POLE 1/4"(6mm) 0 BOLT TOTAL 2 BOLT HEAD MOUNT 1 MOUNTING BRACKET STEEL STRAP SECTION C -C NOT TO SCALE SPB 2'C(53C)(EX), ONE 6 -PAIR SIC(EX) BEFORE EXCAVATING CALL U.S.A. UNDERGROUND SERVICE ALERT 800-227-2600 TOLL FREE 48 -HOURS BEFORE ALL PLANNED WORK OPERATIONS FASHIONISLAND BLVD. 1_9th-AV€ EXISTING MODEL 870 CONTROLLER IN TYPE 332 CABINET WWV ANTENNA SEE ANTENNA MOUNTING DETAIL (DETAIL D) EXISTING MODEL 170 CONTROLLER IN TYPE 332 CABINET C SYSTEM NO. 35-101-11901 EXISTING TYPE A SERVICE (120/240V). EXISTING LOAD: 950 Watts of Traffic Signal (120 Volts —Metered) 2-200 Watt HPSV Luminaires (120 Volts—Unmetered) PROPOSED LOAD: 950 Watts of Traffic Signal (120 Volts —Metered) 2-200 Watt HPSV Luminaires (120 Volts—Unmetered) C WWV ANTENNA RISER 1/2" THREADED WATER TIGHT STRAIN RELIEF FITTING FOR WWV CABLE DETAIL D --ANTENNA MOUNTING DETAIL NOT TO SCALE APPROVED CALIFORNIA DEPARTMENT OF TRANSPORTATION FO ECTRICAL FEATURES A FECTING STATE FACILITIES Lein / '- DATE m DESCRIPTION w a a W W z 0 z W w 0 0 o_ (I) Q 0 SLAND & DELAWARE S I Q } CD W I - a W z z w U Q 0 (f) C V p �J c d 7 'C a 0 U, ce 0 0 0 a J m a- I< 0 0 U w CALIFORNIA SURVEYED BY W I- 0 0 z 0 0 m DRAWN BY ACAD DATE 5/02 CHECKED BY AS NOTED W J C-) N PROJECT NO. 09-90-55.34 CASE 1 DRAWER 15 SET 16 SHEET 3 OF 3 \97003\502\19th9--05/01/02 AS BUILT