Loading...
HomeMy Public PortalAbout06-0305 INTERNATIONAL FIREP Inspection Report 1 4' City of Tybee Island 403 Butler Avenue P.Q. Box 2749 Tybee Island, GA 31328 Phone: 786 -4573 extensions 104, 107, or 114 Fax: 786 -9539 Perim iv+--. C) 3 - 0 -5 L4? Owner's Gen. Contractor: .kr Contact Number: Date Requested: )Ildlcc Date Needed: ;�/,/ b O� Subcontractor: 1 iv7 c eN�? Ui1/�L Location: #7� 3_ F%ea yo £ek Date of Inspection: 7 /U Z001 Type of Inspection: SeewxlrK F✓�C Comments: `� Ss Inspector: &2= ;)/0 Time of Inspection: U��w DATE ISSUED: 05 -16 -2006 WORK DESCRIPTION: WORK LOCATION: CITY OF TYBEE ISLAND BUILDING PERMIT SPRINKLER - MIKE ROACH 3 SECOND TERR OWNER NAME INTERNATIONAL FIRE PROTECTION ADDRESS 5578 EXPORT BV CITY, ST, ZIP GARDEN CITY GA 31408 CONTRACTOR NAME 1_11111:1 pmt CITY STATE ZIP FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE TOTAL FEE'S CHARGED PROPERTY IDENTIFICATION # PROJECT VALUATION INTERNATIONAL FIRE PROTECTION 5578 EXPORT BV GARDEN CITY GA 31408 P $ 32.25 $ 0.00 TOTAL BALANCE DUE: PERMIT #: 060305 $ 32.25 It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire, soil and sedimentation, wetlands, marsblands protection and shore protection ordinances and codes whether local, state or federal, including all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be approved by the issuance of mother building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: P. O. Box 2749 - 403 Butler Avenue, Tybee Island, Georgia 31328 (912) 7864573 - FAX (912) 786 -5737 www,cityoftybee.org 06/30/2003 15:06 B66- 7B6 -SI3( UllY ur IY6Lc I5Lunu rHu� ni CITY OF TYBEE ISLAND INSPECTIONS DEPARTMENT P.O. BOX 2749 TYBEE ISLAND, GA. 31328 PLUMBING INSPECTIONS PERMIT ()(a -03oS CONTRACTOR _n��R% /��NiO/ Yl /TE �12o9 CONTRACTOR'S ADDRESS- SS Z_9 C}',40llt aL ✓J. e/41DEti) JOB ADDRESS S� S )Z' OWNER_ �!_ ( /�E /CdAICA AA WORK WILL BE READY FOR INSPECTION L)�Jt ......... .. .... .................. ... BACK OIL OR GREASE WATER SERVICE I INTERCEPTORS LINES -NEW FLOW PREVENTOR RESIDENCE COMMERCIAL DISP. PLUGGED OR WATER SERVICE FIX. OPENING LINES UP TP 1 1/2 HP EACH REPLACEMENTS DRAIN ROOF OR PLUMBING WATER FIXTURE SOFTNERS AREA EACH DRAINAGE OR VENT REPAIRS /ALTER OTHER PIPING REPLACE FIXTURE FIRE PROTECTION RESIDENTIAL �[ SPRINKLER SYS. DISPOSAL PER HEAD UNIT HOSE BIBBS WITH RESIDENTIAL OR WITHOUT HOUSE SEWER VACCUUM BREAKER ICEMAKERS VACCUUM BREAKERS LAWN SPRINKLER WATER SYSTEMS EACH SERVICE MAINS INTERNATIONAL FIRE PROTECTION INC. "Complete Fire Protection Service" TO: LETTER OF TRANSMITTAL www.candolFP.com MIKE ROACH DATE 4/12/2006 #3 SECOND TERRACE ATTENTION MIKE TYBEE ISLAND, GEORGIA REF: FIRE PROTECTION CONTRACT# IFP# 13DO6139 WE ARE SENDING YOU ® ATTACHED [:] UNDER SEPARATE COVER ® SHOP DRAWINGS ® HYDRAULICS ® EQUIPMENT SUBMITTALS rl COPY OF LETTER CLOSE -OUT 0 OTHER THESE ARE TRANSMITTED AS CHECKED BELOW: ❑ FOR APPROVAL ❑ FOR REVIEW AND COMMENT X❑ FOR YOUR USE E❑ AS REQUESTED PLEASE RETURN E0 COPIES WITH COMMENTS /CORRECTIONS AT YOUR EARLIEST CONVENIENCE. REMARKS: IF YOU HAVE ANY QUESTIONS OR CONCERNS REGARDING THIS PROJECT, PLEASE FEEL FREE TO CONTACT US. 5578 Export Boulevard • Garden City, Georgia 31408 • 912 - 966 -0444 • Fax 912- 966 -1144 24 -HOUR EMERGENCY SERVICE INTERNATIONAL FIRE PROTECTION INC. "Complete Fire Protection Service " PRODUCT SUBMITTAL for MARK ROACH RESIDENTS #3 SECOND TERRACE TYBEE ISLAND, GEORGIA 31328 INTERNATIONAL FIRE PROTECTION 5578 EXPORT BLVD. GARDEN CITY, GEORGIA 31408 (912)966 -0444 phone (912)966 -1144 fax http://www.candoifp.com IFP Job #13D06139 CONTENTS 1.) Hydraulic Calculations 2.) Equipment Data Sheets www.candolFP.com 243 Royal Drive • Madison, Alabama 35758 • 256 - 461 -9988 • Fax 256 - 461 -7839 • Fax 256 - 461 -1292 Corporate 24 -HOUR EMERGENCY SERVICE _ _ Fire Protection by Computer Design INTERNATIONAL FIRE PROTECTION, 1541 ENTERPRISE DRIVE FAYETTEVILLE, AR 72704 479 - 973 -0721 Job Name 3RD FLOOR Building Location # Second Terrace Tybee Island, Georgia System 1 Contract 13D06139 Data File Roach061.WX1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 INTERNATIONAL FIRE PROTECTION, 3RD FLOOR HYDRAULIC DESIGN INFORMATION SHEET Page 1 Date 050106 .Jame - Mike Roach Residents Date - 5/1/06 Location - # Second Terrace Tybee Island, Georgia Building - System No. - 1 Contractor - International Fire Protection Contract No. - 13DO6139 Calculated By - Drawing No. - FP -1 Construction: (X) Combustible ( ) Non - Combustible Ceiling Height 8' OCCUPANCY - Residential - Light Hazard S Type of Calculation: ( )NFPA 13 Residential (X)NFPA 13R ( )NFPA 13D Y Number of Sprinklers Flowing: ( )1 ( )2 (X)4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 16.28Gpm System Type Listed Pres. at Start Point - 8.448Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 14x14 x 196 ( ) Deluge ( ) PreAction E Domestic Flow Added - 30 Gpm Sprinkler or Nozzle S Additional Flow Added - 0 Gpm Make Reliable Model F1 RES 4S I Elevation at Highest Outlet - Feet Size 1/2 K- Factor 5.6 G Note: Temperature Rating 155f N Calculation Gpm Required 62.42 Psi Required 29.74 At Test Summary C- Factor Used: Overhead 150 Underground 150 -' Water Flow Test: Pump Data: Tank or Reservoir: Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 70 Elev. R Residual (Psi) - 48 Other Well Flow (Gpm) - 950 - Proof Flow Gpm S Elevation - 2 P Location: Butler Ave. Tybee Island, Georgia P L Source of Information: Tybee Water and Sewer Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C N U n m 3 z x c D 0 w 0 m V vZ 1 M � -1 ;o fD 0--1 U. C °z a D m c m X 0 m n O Z O1 d N 0 N O N ut O x c 0 0 m x v n N M -1 W W 0 0 0 0 0 o nnn:* O M CD v Cn N N N N C O and ? -u m O N F N C 0 C (D cower Oi N O O O O W O O T O zW 0 >o u, V O O co 0 0 (D 3 In Ox2O OOd ,CD W O O N N a (n5 -T, fin+ vDm y � °o a33n33o oSM —v-n� (D 0.—@ o N v N 7� C m 0 N .. .. .......... vN OI ANN to N A N N A LLU V N W V vZ 1 M � -1 ;o fD 0--1 U. C °z a D m c m X 0 m n O Z O1 d N 0 N O N ut O 0 O 3 a c m O m 3 v 2 n 'm n A A O m a d 3 z C N D 0 w 0 V N <-ir 0 �T W Z T mm �m <� r z T�Q0 C2 zm 0D amo��. Si mn A� W CD ?. f c m n Q N og2m ^n r U7 m i o m m T C mmfm U A 3 �f v 3 v o M M n I � O 21"W—O" 1 \' ? I` j � I I 0 m y I m NU�NNON I� m T X dOIWNOW � O m N I m 0 o W N O A !a m m n 0 -noo N I f 1 N la I N (n ut I O N" W W J a NNO>N� A N O O In N o woo w-• O A m U� W dl I O OI N O OOmOV iN ! O+ A V N W fly A I ODD NC g CC V dd (D m (D OtO to W _ OM im O W L" OO W j(!i O i00 yA W V V W,. ,11 1 ary - o 1 ry v Ljrvw INTERNATIONAL FIRE PROTECTIC Page 4 3RD FLOOR Date 050106 Node Elevation K -Fact Pt Pn Flow Density Area Press u� D001 30.0 5.6 8.45 na 16.28 0.05 102 7.0 D002 30.0 5.6 7.2 na 15.02 0.05 141 7.0 D003 30.0 5.6 7.0 na 14.82 0.05 187 7.0 D004 30.0 5.6 8.48 na 16.31 0.05 187 7.0 7 30.0 8.91 na 4 30.0 7.16 na 5 30.0 7.6 na 6 30.0 9.54 na 1 30.0 8.67 na 2 30.0 9.82 na 3 30.0 9.87 na 30.0 TEST 2.0 31.54 na The maximum velocity is 10.06 and it occurs in the pipe between nodes 5 and 6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen - Williams INTERNATIONAL FIRE PROTECTION, Page 5 3RD FLOOR Date 050106 4yd. Qa Dia. Fitting Pipe Pt Pt ef. "C., or Ftng's Pe Pv " " "' Notes Point Qt Pf /Ft Eqv. Ln. Total Pf Pn D001 to 16.28 16.28 0.0 16.28 1.101 IT 9.563 0.330 8.448 150 0.0 9.562 0.0 0.0464 0.0 9.892 0.459 8.907 D002 15.02 1.101 IT 9.563 0.330 7.199 to 0.0 9.562 0.0 150 0.0 9.562 0.0 5 15.02 0.0400 0.0 9.892 0.3_96_ 7.595 0.0 150 0.0 9.562 0.0 15.02 0.0 13.602 1.940 7.595 D003 14.82 _ 1.101 1E 3.825 0.330 _ 7.000 to 12.965 150 0.0 3.825 0.0 4 14.82 0.0390 0.0 4.155 0.162 K Factor = 5.60 Vel = 5.49 K Factor= 5.45 K Factor = 5.60 Val = 5.06 K Factor = 5.45 K Factor = 5.60 Val = 4.99 0.0 14.82 7.162 K Factor = 5.54 D004 16.30 1.101 1 E 3.825 0.330 8.478 K Factor = 5.60 to 150 0.0 3.825 0.0 1 16.3 0.0465 0.0 4.155 0.193 Val = 5.49 0.0 0.0 16.30 8.671 K Factor= 5.54 16.28 1.101 1 T 9.563 3.950 8.907 to 150 0.0 9.562 0.0 6 16.28 0.0465 0.0 13.512 0.628 Vel = 5.49 0.0391 0.0 16.28 9.535 K Factor = 5.27 4 to 5 5 to 6 6 to 3 1 to 2 2 to 3 -3 to `EST 14.82 14.82 15.02 29.84 16.28 46.12 0.0 46.12 16.30 16.3 � �, 76.12 92.42 0.0 92.42 1.101 0.0 11.080 7.162 150 0.0 0.0 0.0 0.0391 0.0 11.080 0.433 Vel = 4.99 1.101 IT 9.563 4.040 7.595 150 0.0 9.562 0.0 0.1426 0.0 13.602 1.940 Val = 10.06 2.003 IT 12.965 6.540 9.535 150 0.0 12.965 0.0 0.0173 0.0 19.505 0.338 Val = 4.70 9.873 K Factor= 14.68 1.101 150 0.0466 2.003 150 1.985 150 0.0654 1T 9.563 0.0 0.0 1T 12.965 0.0 0.0 1 G 1.241 2L 7.444 1Y 13.027 1 Zfb 0.0 15.120 9.562 7.120 12.965 20.085 33.540 21.712 55.252 8.671 0.0 1.151 9.822 0.0 0.051 9.873 18.054 3.616 31.543 Val = 5.49 Vel = 1.66 Qa = 30 ' Fixed loss = 5.927 Val = 9.58 K Factor= 16.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard INTERNATIONAL FIRE PROTECTION, 3RD FLOOR Hyd. Qa Dia. Fitting Pipe Pt Pt ief. "C" or Ftng's Pe Pv Point Qt Pf /Ft Eqv. Ln. Total Pf Pn Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Page 6 Date 050106 * * * ** Notes * * *' ** 'AAr MODEL 8000/8011 ill 11/411 11/211 211 The AGF Manufacturing, Inc. 11/4", 11/2' and 2" Model 8000/8011 RiserPACK Are Easy To Install, Economical Riser Assemblies Designed To Provide A High Quality Finished Appearance For Large Single - Family And Multi - Family Residential Fire Sprinkler Systems J Complies With NFPA 130 Requirements For A Properly Sized Test Orifice. Available With Test Orifice Sizes Of - e . 7 /ts" ', 11 /s" And 5 /s" (ELO) J Lettered On Both Sides To Provide Required Sionage And Allow For Left Or Right Drain Installation J Includes UL Listed Patented AGF 1" Model 3011 Ball Valve Which Includes A 1/2" port For System Pressure Testing And Optional Relief Valve Installation J The Unique Model 3011 Ball Valve Design Saves Hours Typicailv Wasted By Eliminating The Need To Crain The System After The Hydrostatic Test To Install The Optional Relief Valve J Can Be Either Surface Mounted Or Installed Between Most Standard Stud Wall Framing Mot J Available With UL Listed. FM Approved AGF Model 7000 Relief Valve Equipped With A Flushing Handle To Eliminate Dirt Causing Drip Leaks I The 11/4 ", 11/2" and 2" Model 8000/8011 RiserPACK Is Also Available In Commercial Trim With Or Without An Optional Relief Valve For NFPA 13 Systems. Please Ask Your Distributor Or Call AGF Manufacturing. Inc. For Details Accinonal Space may be necosary to ancw'._r `:0r oM n';; r:,; t •r, y:q,.,. Valve hande c:earance tequwaC_4ao LIT hancle cleararce mqu reC -acr 3111' 9 C� o— V i -A r -1 -� ^ _ I _ A cu t i AGF MANUFACTURING INC. 100 Quakw Lane JOB NAME: .. Malvern, PA 19355 USA Telephone: (610) 240 -4904 ARCHITECT: _ •4 w, 31." I I . Size . A B C D 3q^ 12 ,,," 4 34" 6 1j,- mm ]il mm 121 mm- 159 mm c c ! 1 114" 11 ^ 12 111" 4" 6 1 %2" �� 219 mm 311 mm•• 1@mm fi5 mm i 1 1/21' 12" 112 ,/2" 4 1,8^ 6 5/a" ]0Smm 317 mw. 105 mm 1Cd mm 2" 13" 4Its" 61 /e" 39sZ'm 329 = 111 mm 174 m 1 rr 10 3/4" 112 1/4" 2 713" 6 1,,^ 273 mm ]IImm 11 m... 159mm l4m /m 6fislmm• Z�i11j4,' 39,5 t0�mm 2 m l 1 1/2' 14" 115 1/4" 4 1%8" g s %s^ 387 mm 3l7mm I 105 1W 2" 1]e mm 115 31," 4 3 /s^ 6 7 /s" ],,, 111 mm its Accinonal Space may be necosary to ancw'._r `:0r oM n';; r:,; t •r, y:q,.,. Valve hande c:earance tequwaC_4ao LIT hancle cleararce mqu reC -acr 3111' 9 C� o— V i -A r -1 -� ^ _ I _ A cu t i AGF MANUFACTURING INC. 100 Quakw Lane JOB NAME: .. Malvern, PA 19355 USA Telephone: (610) 240 -4904 ARCHITECT: _ Model 850 (112" - 2") 3 ill' 8 12.2 7 1.4. _ 2 _ / L _ C, (5: 4, 2. 6 Dimensions and Weights U.S. - Inches (mm) NET WT. SIZE A B C D E Lbs. (kgs.l 4: 10 (254.00) 111, (38.10) 11y (38.10) 311, (79.38) 1'l. (31.75) 4 2 1 1.9' 31." 1031. (273.05) 116 (38.10) 11;, (38.10) 3'1. (79.38) 14, (31.751 44(2,00) V. 1216 (317.50) 111, (47.63) 1% (41.28) 3'4 (85.73) 1'6 (38.10) 6 8 (3.C8 i 11" 1534 (403.23) 3(76.20) 29, (63.50) 44, (107.95) 2'4 (57.15) '5.8 17 17 1111," 1634 (415.93) 3(76.20) 2'!, (63.50) 44, (107.95) 211. (57.15) 16.2 (7.351 2" 1731, (447.68) 311, (88.90) 2'!, (63.50) 4 ^. (107.95) 211, (57.15) 21 1 t9.57' Note: Dimensions are nominal. Allowances must be made for normal manufactunng Irlerances FEBCO Backflow Prevention REM DESCRIPTION MATERUILS 1 Body Bronze 12 Tailpiece Bronze 13 O -Ring Silicone 2 Cover Bronze 22 O -Ring Silicone 3 Seat Noryl 3' O -R:ng S10ccre 4 Popcet ucr�l = Seat Cise Snccre 5' Disc Retaner Ncr,i _. Rnc'-D Saew Stainless Sl&ti - $Fong Starless Ste: - 7 Guice Ncry, Retainer Soacer Ncr.i i Bail Valve iH7ac: erczre, _ Bail Val" 3fcr._ Test C:.cx _vxze .�.' Hex HO CacsGew Slairwss Steel 6C Icent:6cancrt Plate Brass 5' Onve Scow Soo St- iirless Seen Model 850 (112" - 2") Check Assembly ' t Single Inlet Connection for Residential Sytems, UL Listed Description Designed specifically residen- tial sprinkler systems, the Single Inlet Connection fea- tures all brass contruction with an intergrally cast mounting/ identification plate. The con- nection comes equiped with a single 1 1/2" NST gasketed female threaded swivel inlet and a 1 1/2" NST plug to portect the threaded swivel from damage or the intrcduc- tion of foreign materials when not in use. The out let is 1 1/2" i NPT female thead for connect to the end of 1 1/2" threaded male pipe. The intergrai mounting /identification plate has three drilled mounting holes for attachment to a mounting surface such as an exterior wall of a building or other structure. Fassteners used should be suitable for the material to which the connec- tion is being attached. Installation ; Specs Install according to applicable Material: codes using customary instal - Brass lation methods for for the installation of threaded con- I Type: nections. A suitable threaded sealant such as PipeFit ! Single Outlet PL Thread Sealing Paste with PTFE or PTFE thread Sealant i Size: Tape should be used. Where re uired - c ^e k I I q , c va ve snoU d : 1.5" FNPT x t5 FNS' i be used to maintain system pressure. fpp�l ©1996 -1999 Fire Protecticn P- cduCts ,. Other specifications: Integral Identification sign "Auto Sprinkler" with mounting holes. F:;r �auestu,r.. :GC t.t. ,i %T( hl'D : •.v.vN as :::m m ®Mode! F1 RellabiliResidential Model F1 Res Sprinlders engineered for the lowest flows to meet the minimum design density of .05 gPnW Types: 1. F1 Res 49 Pendent 2. F1 Res 49 Recessed Pendent/F1 3. F1 Res 49 Recessed Perdent!FP 4. F1 Res 49 CCP Perden: 5. F1 Res 44 NSW 6. F1 Res 44 Recessed HS'WiF2 7. F1 Res 40 HSW S. F1 Res 40 Recessed HS'4VF2 Listings & Approvals 1. Listed by Underwriters Lnccralcr:es irc. arc UL Certified for Car.aca (ciJL,_s) 2. NYC MEA 258 -93 UL Listingg Category ResidentiarAutomatic acrncc, UL Guide Number VKKW Patents US Patent No. 6.516.E93 acciies :c to Model Ft Res 49 Ferdert Scr'rkters Product Description Model F1 Res Pendent scr!rk:ers (Fits. 1.2.3.8 a) are fast response sprinklers comciring e. ce lent duraciiity high sensitivity glass_ -Cult arc :c:v Ordile ceccrativE desien. The F1 Res Hctzcrta! S:ce.val sccrk,e!s IF:cs_ 5 E 6) are equally aRraz vc ,.vrEn accvc ceiling c!Crc cannot to usec. The 3mm class -tClt CerCErt SCOrK:ers. K- Fac ;cr of 4.9, pErr..it ire eff;C:eri use CI fc CEn;:a! Water suD011es fer sorirkfer COVE age :n res!centla! i;r= protecticn desicn. The Ic..v `Ic%v F1 Fes scr r c crs =7o scec:a EriCIrEE!EC 'Cr fast :.`.'er.T,ai r=scCFse 'C r-E9r •_E sensitive fire prclecicn accliCa ::Cr rEeCS C; :re .arES: residential market sarcards (LL lEC Starcarc Upon fire conditions, r(s.n0 hez: Causes a scrr.k:er f eat- sensitive class -Wt t0 scatter, rveasir•C :re waterway fcr Water f,cw ontc the cerleO :cr. cyp� distributing the disc ^arced water IC CCnirzi a -ire Technical Data: • Thermal Senscr: Ncr-;ra! 3r-- C!ass -t t Sprinkier Frame: Erass Cas;;r.e • Scrinklers' Pressure Faring Factory Hycrosiaticaay Testec :e S :CO cs; • Thread Size. "" NFT (R ;:) • K- Factor. a.9 (A.ctua!) - F1 has -9 FEnccm Sr.* rK.:er -1.4 ( Actua!) - F1 Res i- HS'.Y Sc ^. :er •1.0 (Actual) - --I Res -0 SSW C. el • Density: Minimum O.CS cpm ;' :< Eulletin 135 nev 6 Sprinklers Application f . SrCer't %:1 rjA� •. c. !rat cr' CE = CE. rtE'TCEti.,,•? -97 7. scrr, .E• - a,- . _ =SSOC a:.Cr. C -' -.cr'. ... Lr:SC:C: c.' - Installation MCCE S" FEs_ "�= ...3• :C -'S[ CC qre :re %ICce' C r,er: Mcdet Cilec. %.a a 1- , The Reliable Automatic Sprinkler Co.. Inc.. 545 KCr•: �,1 7C;a,E,• r.:= tr; , Q c n 2. Model F1 Res 49 Pendent Model F1 Res 49 Recessed Pendent /F1 ;1 3d,;ustr".8'1' e• —r. � t i Technical Data: F1 Res 49 Pendent and Recessed Pendent Sprinkler Max. Thread Temp. Max. Ambient Ac.ual Sprinkler Size Rating Pressure Temo. K Length 'F -C Psi (bar) 'F .0 Fac.or Inch (mm) Ddk?c!cr - to - ceiling Maodmum 1" (25mm) to 4" (100mm) Max. Sprinkler Spacing Fiow Pressure Sprinkler ft (m) 9pm (Lpm) psi (bad Identification Number (SIN) 12 x 12 Q.&3,6) :3119+ a,•as 14x 11 fa 3x421 !311c. 16 x 1611 9x4 91 C 16x18 i66xO °1 'if.1 -- 20x2016.1xE.1) =0f ?9" '6-.• Deilecicr - to - ceffirc Ma;dmum 4" (100mm) to g' (^x,rr.m) ' Max. Sprinkler F Sprinkler Spacing ow Pressure ft (m) SPm (Lcm) psi (bar) Identification er1�IN) '1 X71 (4.3x1 16 i6__• 10 6 <16 i1 nxJ.3) Note: Tte F! 4c _ ' res;cennai - �,•n.: =Vs s :zr'�_ :_ Escutcheon•. F1 or F2. Data: ACM1smw" .. _. A" FX—' a Sere 'c Typo tcllmm) :ncl�mml rollns Note: E5":cnecrs r Y a,•as Y Model F1 Res 44 Recessed HSW/F2 Technical Data: F1 Res 44 HSW & HSW /F2 Sprulfda M= Thread Max Sae Rati Prue 1 Term ' Factor Ljm-AP °F °C I '"' I ,F -C tr1cl1(mm) I %' NPT 1 175 79 155) E8 ' 100 38 F } 175:12! 15_ 44 2 - Z :E` ( ad��s:r-er. Escutcheon. F2. Data: _ Pam d Fftig Ad Tom. ts:1�mm kbo wad i71_ -- F2 '!1131 - _ "A" Maz.Sprinkkr : Ceiling {p SprinkferTe-p. F<.w Pressure Spa �9 Deflector F IC GPM (LPM) psi (ba7 ft krh rrt,rt,l ! 12x 12 (3.&3.61 155(E21 1'S.-91 -,2, ! 11 x 14 (4.3x4.3) 155 (E8! 175 'Q` 14 t5g 2) - 16x16(4.9x4.9) 4 -E 155(EF 175,791 16 (EO c� 116x 18(49x5.5) 1 (101 - 152? 158(Ecl 175(;9) 15(E81) '6= 161 18x18(5.5x5.5) 155(E2i 17-A (79) 10 (72 C) 16 x20(494.1): 1155(621 175(70) 23 i57" ' 12x 12(3.6x3.6) 155(EFP 175:791 1415301 14 x 14 (4.3x4.3) 1 : 155 iEc 175 (70) 16160 E'� lox16(49x4.91' 6 -12 (102 -'C5 155'E61 . - 17E(;91 17¢44 _ 16 x 18 (49x8.5) 155 iE51 791 20 f75 16 x 20 (49x6.1) c_ 1_5 `E-' 6 'q. X97 3 ' .y .. W.rwer bertrfieuion rkanber(SN Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model FiFR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal S cewail - HSW 1 Deflector Listings & Approvals 1. Listed by Underwr3Ers L= tcra:cLes. Irc. tLL 2. ListedbyyUnder wr :ters'LatCra:CCESC;Cara_a(L'LC' 3. Certified by FM A.ccrcvais 14. Loss Preveraicn Ccunc,l (LAC. 'K' 5. NYC BS&A No. E87-75.4,z - E. Meets MIL- S-301C and MIL -37C :c %. Verband der Schacenversfc. -c. 'l %CS. 8. NYC ME4 258-93-E UL Listing Category Sorinklers• Automatic & Qcen Quick Resperse SprinWer UL Guide Number VNIV Product Description Reliable Mcde!s Ft F= and FtF- =ECG -Sc rrkes ar= quick respersE scr rk'E s sunken, rCrE —,e star lard scririi& Wt Ta a ?ac.bc ClJ crc'E _• 3 C1 (a SE scnnker. The Models F i Fa ane F 1 Fn Receessec a tcr, a- scrr.RE u4iize a 3.0 mm karlade class cub. Try scrrxers -a-'.e da rcr� rated Es ir. accracrJ:ESS :.rcr, are ;,e t0 te: i tirrEs 1aTr=r then star oar0 'EECCr -% SOM -X:E3 cUck resOcnsE enacles t-e MCCe: - • r� a .c ='r FC1,.,n -SSc_ sprirk e s to acpiy wa:E to a S e coon "ale Tar 5arca c scrink;ers of the same ,errcera Lre arrc. The Glass bulb ccnSiSs cf an EC__Ua!E'V CCrC0!EC_ ar-Cu : C<Specid fluid hE .etm v se:-!E- f S cc a crE��EV Tc'rl is . lured class cacsu!e. Trs aass tuvc c SCEI_zhJ CCrsT c eC C CfGVlde fa5t'JlE?Tc -I reSCCGSe, Tr2 Leancc C' Care are r7ac-_ Cf crass. copper and tc�JiBum nave!. At normal temceratures the class tc,t C_, rs :re •!u :c r. tcih the liquid ane vac, phases. Tre :a cr rase ccr ce seen as a small butcle. As heat s accnEC re icule ax canas. fCfCing the blaC!e smaller arc S,—, 2,C, as .,c !IGCIC cressure increases. Ccrrnueo reailrg `crcEs the'iquic :C Cush cut against the -ulb . causing tre g +ass :c sraner ccening the waterway and allcw!cc the ces!e_;cr :C clsrr• cte the cischarcing wa-Er. The temperature retire ci the sC"l -Wer is cent:rzed tv tre Colcr of the glass tint �ulletfn 136 Rev L GO Model F1 FR Model F1 FR Recessed Quick Response Sprinklers Application, 1, l;:C }. .ef`_ ^__ _ • arc The Reliable Automatic Sprinkler co„ Inc. -25tlCr` =-r- d� i i I I ._ -c.:._ .. z . Application, 1, l;:C }. .ef`_ ^__ _ • arc The Reliable Automatic Sprinkler co„ Inc. -25tlCr` =-r- Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Mcdel D Sprinkler Wrench Installation Data: Sprinkler Type SUrdard- Uptight (SSU) and Pendera(SSP) Deflectors Marked to ktccale PosbCn I US K Fedor I Metric Sprinkler Wight Approval Organization 5pn Nkkml lownfflcadon - SSU SSP J'(15mm) Stardard Onfiae kwth —.NFT(FA Frew Sc 1 e0 c i 2mm) Larce Once with 3l- \FT 8 - 2 2' ';d:= _. 0 7mrrl small Onfice with Y"W-F!1 -,h•e,:c 42 CO 2 =2C'7 lY' (*=) Snail Orifice with Y "%_ F` 7•u^ 28 ?. _. 1cmm Orfice XLH with RY "Thrc_ °o I rm _ "r. : -_. -?_�•; _ 1 Come nucrai -lrwafi in L'cr:cht cr Fec1z ?Cs .. ttlrrm nm'. Y14 w0. L`7/ Th—.' ^t_ _0' lmkr - -- - 15mm Sirrcard Crifice with/'N.- .== .'rez] 20mm Lace Cnfice wM ?!i NFT • FF,: Model F1FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Mccel RC-, Sprirkler Wrcnc� Installation Data: ' Nominal Thread K Factor Sennktar aocrevai Orifice Size Us Metric Helgnt Crgarvaticni, ]= .cc" —• Refer:o esc;;tcnrn ca:a :a.e •cr -=Z. a s arC C cers.crs - - -- yn.• r .�.n n.an •i I r r ..a ....r.� . 07SYa �1 1 is v— (.•� ti..i �� arn'u nr .on .a rn*ww nr. ,.� ,w .•�c..r Scr'r.. Cr Iccn W,cal:cr 'kcmeer Siw c i Model F1FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Mccel RC-, Sprirkler Wrcnc� Installation Data: ' Nominal Thread K Factor Sennktar aocrevai Orifice Size Us Metric Helgnt Crgarvaticni, ]= .cc" —• Refer:o esc;;tcnrn ca:a :a.e •cr -=Z. a s arC C cers.crs - - -- yn.• r .�.n n.an •i I r r ..a ....r.� . 07SYa �1 1 is v— (.•� ti..i �� arn'u nr .on .a rn*ww nr. ,.� ,w .•�c..r Scr'r.. Cr Iccn W,cal:cr 'kcmeer Siw Model Fi FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: I I K Factor ; Approval Sprinkler Identification Nominal Orifice Thread Size US metric Sprinkler Height i Organizations Number SN ih, I 'h' NPr (F �) S.d I 8C 22' (56mm) 1 1. 2. 6. 8 r2ti85 15mm I i? NF? (R ".t) 5 c I 80 22' (Scmrr 1 d "n i'1 LPC Accrcval is for Pendent ccsnsn crp Vertical Sidewall Orientation Deflector to Ceiling Dimension (Min. - Max.) Pence.^.; 6'-'_'1'S 7r- ar.c..r. l Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Scrirkler Wrench Installation Data: iApproval Drw ts s K Factor and Type of A�l Sprma:cr Nominal Thread 'eenutica:X Orifice Size us Metric SLengthr Light Crelnery Numoer Huard Hazard $IN• oimm) i /.• NFS(F.:il 5 6 6C , 6 1' .6"mr: Z 1 Z ___ . _.... NOTE: UL arc UL'- Lasurg cermts ese aGn =: cr P2 recessed e`.CCidreC- - -- - - _ s I — i I Horizontal Sidevia l Installation Quick response sprinklers are intended fcr installation as specked in NFPA 13. Quick re Tse sprinklers and standard response sprir k!ers shoulo not be intermixed. The Model F1 FR Recessed Quick Response Sprinklers are to be installed as sham. The Mode! Ft cr F2 Escutch- eons illustrated are the only recessed escutcheons to be used with the Model F1 FR Scrinklers. The use of any other recessed escutcheon Wil void all accrcvals and negate all warranties. When installing Model FlFR Sprinklers. use the Model D Scrinkler Wrench. When frstalino Model FlFin— Recessed Sidewall Sprinklers. use the Mccei C-=;, Scrinkler Wrench. Use the Mcce! RC! Wrercn fcr :r_<:aline F1F7r, Recessed Pendent Scrink'Ers. Pr: carer ^:ce cf wrercn may damace these scrirKE'S. Temperature Ratings Classification Sprinkler Temperature Max. Ampient M=. Bulb Celer °C °F Interrre(aa:e '- _c z-C: ••_ICx an:errrecia:a c' 'S 'S: c- .5E'C'. > >r I HICK' F 1 Nct avaiacle Icr recassec sC' r< ers Escutcheon Data EFaMpm fiats Amsmem CYnamv; Fin k a Wad chasm F_ 12.3.4 s.7g itreap -cl Maintenance The Mcde!z FIFE arc FIFn Fec=G_<_ec rK,er3 should be Inspected CGUFr:F :v arc :re SC:: ^K:E! S/SiE7 maintained in acccrcarcE 'min NF;'-, 25 Cc -r, C`.Ecn scrink!ers with scat arc ,vc er, ar"crla Cr ary C;rer C'eanirc fluids. Re rcve CCs: cv us;rC n Sc" C' n �( Cer- t!e vacuuming. F.Ercve any SCrIrK:E :`.r.0 -ac CE_r cainteo (cihe! than raC :Cr'., azc4eC1 ::r Carra we,/. A sICCK M SCa!E Kr 714]_S 5._C_:C CE Tcric'.rE'C a!ICw CUCk replace!rEri :7 ..a:rac:& ='ac sG'C- k!ers. Prier is installaccr. SC-rK ors S._CC:C "e 17cr1elrec I in the crcinal canons arc c =_c: <ac:rc cci _ c :c -in- mfze the cctentlai [Cr Cc-2CE iC S:Cr'K;E'3 ;`,a: 'ACUC C2L'S21mp(CCer CCErarcr, Cr -cr ccera::cr apnntcter types Standard Ucnght Standard Pendent Conventional Sidewall (Vertical. Horizontal HS'+xr1) Recessed Pendent Recessed Hcrizonta, S cewa,l Finishes 1 "" Standard Fntshc swnkler E;cutchecn - , :acme cla:ec - - -. Sm:al Aocir ucn Fnor1L-9 Sonnklcr -- _ - -' Ex_=a r = la:e.. _ _ix Pi r1 ._ Ordering Information Scer: ^Y' I Mcce, _. Oer:rK!E! -.Ce 3 Crfce S:ze C&ec:C.r Cc Note: = (,:erec .re scree er: - - S.`.e 2cPtxe ^.: IX2ee. ^.IeC n:^ c:.ce'r 5'pc2 - a: c- C ::fie! n'm,r _'-.ar:+' -" .r^ •.Oran •..._n d'Nl .......... .. . .. _ __ _.1:sc :. -- - - . P:cecrirk er Ij:araa ••• c u•catt••r, r ,. _ e scnrx a ,:cr;;aacrs'cca;ec 3az1 :,.r..3 Ntanulaacree cv RThe Ret^apla Automatic Scrrnka Co .':r: FPa CITY OF TYBEE ISLAND INSPECTIONS DEPARTMENT P.O. BOX 2749 TYBEE ISLAND, GA. 31328 PLUMBING INSPECTIONS PERMIT CONTRACTOR �ii/ / E%z �✓n%4 )' / ,J CONTRACTOR' S'ADDRESS SS 7c,tiT 7z VV). Ef./ �'f, �'/� ��Y14 JOB ADDRESS � � �� @cchv9 �ET21Z. �f�Y� �/�iv✓ u�A l ✓. 3/3 15 OWNER_ WORK WILL BE READY FOR INSPECTION�� /t -- ---- __-az = = = == ......... --------- - -- --- BACK OIL OR GREASE WATER SERVICE I INTERCEPTORS LINES -NEW FLOW PREVENTOR RESIDENCE COMMERCIAL DISP. PLUGGED OR WATER SERVICE FIX. OPENING LINES UP TP 1 1/2 HP EACH REPLACEMENTS DRAIN ROOF OR PLUMBING WATER FIXTURE SOFTNERS AREA EACH DRAINAGE OR VENT REPAIRS /ALTER OTHER PIPING REPLACE FIXTURE FIRE PROTECTION RESIDENTIAL �[ SPRINKLER SYS. DISPOSAL PER HEAD 2I1)03 UNIT HOSE BIBBS WITH RESIDENTIAL OR WITHOUT HOUSE SEWER VACCUUM BREAKER ICEMAKERS VACCUUM BREAKERS LAWN SPRINKLER WATER SYSTEMS EACH SERVICE MAINS