HomeMy Public PortalAboutORD 111_Adopting 2003 Plumbing Code_02192007[-
ORDINANCE NO. I ( I
AN ORDINANCE OF THE CITY OF IONA, IDAHO,
ADOPTING SECTIONS 7-5-1 and 7-5-2 OF THE CITY CODE
OF IONA, IDAHO; PROVIDING FOR THE ADOPTION OF
THE UNIFORM PLUMBING CODE, 2003 EDITION;
PROVIDING FOR CERTAIN AMENDMENTS TO THE
UNIFORM PLUMBING CODE; PROVIDING FOR THE
PROSECUTION UNDER PRIOR ORDINANCES; PROVIDING
FOR THE SEVERABILITY OF THE SECTIONS AND
SUBSECTIONS OF THE ORDINANCE; PROVIDING FOR
THE EFFECTIVE DATE OF THE ORDINANCE.
BE IT ORDAINED BY THE MAYOR AND CITY COUNCIL OF THE CITY OF IONA,
IDAHO, THAT:
Section 1. Adoption of Sections 7-5-1 and 7-5-2, Iona City Code. Sections 7-5-1
and 7-5-2 of the City Code of Iona, Idaho, are enacted as follows:
7-5-1: UNIFORM PLUMBING CODE ADOPTED
(A) Plumbing Code Adopted: The Uniform Plumbing Code, 2003 Edition, published by
International Association of Plumbing and Mechanical Officials is hereby adopted
as an official code of the City except those portions that are deleted, modified, or
amended by other provisions of this Chapter.
(B) Code on File: One (1) copy of the Uniform Plumbing Code, 2003 Edition, shall be
retained by the City Clerk for use in and examination by the public.
7-5-2: AMENDMENTS TO THE UNIFORM PLUMBING CODE:
(A) Chapter 1 of the Uniform Plumbing Code, 2003 Edition, is hereby deleted.
(B) Definition of "Plumbing System" in Section 218 of Chapter 2 of the Uniform
Plumbing Code, 2003 Edition, is amended as follows:
Plumbing System - Includes all potable water building supply and
distribution pipes, all plumbing fixtures and traps, all drainage and vent
pipe(s), and all building drains and building sewers, including their respective
joints and connection, devices, receptors, and appurtenances within the
property lines of the premises and shall include potable water piping, potable
water treating and using equipment and water heaters.
(C) Section 313.7 of Chapter 3, and Section 402.6 of Chapter 4 of the Uniform
Plumbing Code, 2003 Edition, are deleted.
. •
(D) Section 412.2.1 of Chapter 4 of the Uniform Plumbing Code, 2003 Edition, is
amended to read as follows:
Toilet rooms containing two (2) or more water closets or a combination of one (1)
water closet and one (1) urinal, except in a dwelling unit.
(E) Section 420.0 of Chapter 4 of the Uniform Plumbing Code, 2003 Edition, is
amended to add an additional sentence as follows:
Exception: Pressure balance or thermostatic mixing valves are not required for
high -flow (over 8 gpm) tub -filler valves with hand showers attached.
(F) Section 421.0 of the Uniform Plumbing Code, 2003 Edition, is hereby deleted.
(G) Section 508.5 of the Uniform Plumbing Code, 2003 Edition, is amended to add an
additional sentence as follows:
Exception: Water heater pans with minimum 1" drains may receive discharge
from 3/4" relief drains.
(H) Section 609.10 of Chapter 6 of the Uniform Plumbing Code, 2003 Edition, is
amended to add an additional sentence as follows:
Exception: Requirements for pressure -absorbing devices shall not apply to
residential construction.
(I) Table 6-4 of Chapter 6 of the Uniform Plumbing Code, 2003 Edition, is amended
as follows:
(J)
The water supply Fixture Units (FU) for Bathtub, Combination Bath/Shower and
Clothes Washer in Private Individual Dwellings shall be 2 FU.
Table 7-3 of Chapter 7 of the Uniform Plumbing Code, 2003 Edition, is amended
as follows:
The drainage Fixture Units (FU) for domestic Clothes Washers in Private Individual
Dwellings shall be 2 FU.
(K) Sections 703.2 And 710.5 of the Uniform Plumbing Code, 2003 Edition, is amended
to add the following exception:
Exception. In single family dwellings, one (1) fixture unit may be allowed for each
gallon per minute of flow from a pump or a sump ejector.
(L) Table 7-5 of Chapter 7 of the Uniform Plumbing Code, 2003 Edition, is amended
as follows:
2
!•
The Maximum Fixture Unit (FU) loading for 1-1/2 horizontal drainage piping shall be
2 FU.
(M) Section 710.9 of Chapter 7 of the Uniform Plumbing Code, 2003 Edition, is
amended to add an additional sentence as follows:
Exception: This Section shall not be required where the pump or receiving tank
receives the discharge of no more than one toilet room.
(N) Section 807.4 of Chapter 8 of the Uniform Plumbing Code, 2003 Edition, is
amended to add an additional sentence as follows:
Exception: A domestic dishwashing machine may be installed without the use of
an airgap if the drain hose is looped to the bottom side of the countertop and
secured properly.
(0) Section 908.0 of Chapter 9 of the Uniform Plumbing Code, 2003 Edition, is
amended to read as follows:
(P)
(Q)
908.0 - Vertical Wet Venting: Horizontal wet venting shall be allowed provided
the wet -vented portion is created in the vertical position according to the
requirements set forth in Sections 908.1, 908.2, and 908.3 for Vertical Wet Venting.
Section 1002.3 of Chapter 10 of the Uniform Plumbing Code, 2003 Edition, is
amended to read as follows:
Exception: For trap arms three (3) inches (80mm) in diameter and larger, the
change of direction shall not exceed one hundred eighty (180) degrees (1.6 rad)
without the use of a cleanout.
Use of Chapter 11 of the Uniform Plumbing Code, 2003 Edition, is limited as
follows:
Roof drainage and subsoil drainage shall be required as specified in the Building
Code, and installed in accordance with the methods and materials of UPC Chapter
11.
Section 2. Severability. The sections and subsections of this Ordinance are
severable. The invalidity of any section or subsection shall not affect the validity of the
remaining sections or subsections.
Section 3. Effective Date This Ordinance shall become effective on its passage,
execution and publication in the manner provided by law.
3
PASSED BY THE COUNCIL AND APPROVED BY THE MAYOR this %9 day of
ATTEST:
Betty McKin
City Clerk
(SEAL)
4
Brad Anderson
Mayor
STATE OF IDAHO
County of Bonneville
I. BETTY MCKINALY, CITY CLERK OF THE CITY OF IONA, IDAHO, DO HEREBY
CERTIFY:
That the above and foregoing is a full, true and correct copy of the Ordinance
entitled: "AN ORDINANCE OF THE CITY OF IONA, IDAHO, ADOPTING SECTIONS 7-5-1
and 7-5-2 OF THE CITY CODE OF IONA, IDAHO; PROVIDING FOR THE ADOPTION OF
THE UNIFORM PLUMBING CODE, 2003 EDITION; PROVIDING FOR CERTAIN
AMENDMENTS TO THE UNIFORM PLUMBING CODE; PROVIDING FOR THE
PROSECUTION UNDER PRIOR ORDINANCES; PROVIDING FOR THE SEVERABILITY
OF THE SECTIONS AND SUBSECTIONS OF THE ORDINANCE; PROVIDING FOR THE
EFFECTIVE DATE OF THE ORDINANCE."
Betty McKinl
City Clerks
G:\WPDATA\DWS\2708 City of Iona \ORD\Uniform PlumbingCodeAmend2004.wpd:sm
5