Loading...
HomeMy Public PortalAbout06-0468 MARY E. ADAMS.pdf" f!�� Weather Shield Mfg., Inc. " " ACKNOWLEDGEMENT WEa6NER it P.O. Box 309 ORDER: 319559074 order #:319559074 SH kb Medford, WI 54451 CQ Order #:438273 Phone: 715 - 748 -2100 Dealer Prj #:3400 �� a Fax: 800 - 222 -2146 Weather Shield Mfg. Inc. Proposes to Furnish Products as Stated Below. Printed:6 /1/2006 12:43:11 PM System #: 319559074 CQ Order #: 438273 Double Hung Tilt Dealer Prj #: 3400 Sold To: 3024619 Customer ID: GUERRY LUMBER CO INC 123 W 44TH ST Nominal Glass Width -20 PO BOX 23859 Nominal Glass Height -28 SAVANNAH, GA US 31403 -3859 Jamb Height -65 1/8 Phone: 912 232 -3128 Fax: 912 232 -1476 Delivery BUS HRS. 7:30 A.M. - 5:00 P.M. DEL Instructions: CONT: DOUG TREDE 44TH & Operating Code - Operating BARNARD ST. Exterior Frame Finish - Aluminum Clad Shipping Instructions: Ship Via: W/S TRACTOR/TRAILER Delivery Week: Order Date: 8/112006 Ship To: 3024619 GUERRY LUMBER CO INC 123 W 44TH ST PO BOX 23859 SAVANNAH, GA US 31403 -3859 Drop Ship: Phone: 912 232 -3128 - �� r 1 Terms: 2% 10TH FM, NET 11 -25TH CUTOFI Salesperson: JOHN FAULKNER All Units are viewed from Exterior. Item Number: 3 Weather Shield Quantity: 4 Double Hung Tilt Total Jamb To Jamb: 25 5/16 X 65 1/8 Rectangle Total Rough Opening: 26 5/16 X 65 518 Product Arrangement -1 Wide Sizing Method - Nominal Glass Size Nominal Glass Size -20 X 28 Nominal Glass Width -20 Nominal Glass Height -28 Overall Jamb Width -25 5/16 Jamb Height -65 1/8 Overall R/O Width -26 5/16 R/O Height -65 5/8 Glass Width -19 7/8 Glass Height -27 11/16 Operating Code - Operating Exterior Frame Finish - Aluminum Clad Exterior Sash Finish - Aluminum Clad Aluminum Paint Finish - Standard PO: 22391 MC JOB NAME: MATHEWS TYBEE LOCATION: Thank you for choosing us as your window and This Order is subject to and governed by Weather Standard Terms and Conditions of Sale. Please click of Page 1 of 2 Order #:319559074 Fax: 912 232 -1476 Exterior Color -White Jamb Liner Color -White Glass Type - Insulated Low E Gas -Argon Lite Configuration -1 Lite Hardware Color -White High Performance Pivot Pin -Yes Screen /Storm -Full Screen Screen /Storm Color -White Pkg Scr /Storm Separate -Yes Weather Shield Mfg., Inc. ACKNOWLEDGEMENT P.O. Box 309 Order #:319559074 Medford, WI 54451 CQ Order #:438273 Phone: 715 - 748 -2100 Dealer Prj #:3400 Fax: 800 - 222 -2146 Weather Shield Mfg. Inc. Proposes to Furnish Products as Stated Below. Printed: 811/2006 12:43:11 PM located on the menu bar on the Log In Form in CustomQuote for a copy of the Terms and Conditions of Safe. Page 2 of 2 Weather Shield CustomQuote System T"" 2.10.0 Order #:319559074 Copyright 2002 Weather Shield Mfg., Inc. ail WEA HER / SH ELD 0 Weather Shield® Performance Data & Information Premium Wood & Aluminum Clad Windows & Doors Structural Performance Data a PRODUCT TEST DATA (Continued) a Units tested at laboratory in accordance with ANSI /AAMA/NWWDA 9 Units require tempered glass. 101/1.5. 2 -97 and AAMA/WDMA/CSA 101/1.5. 2/A440 -05 test k Single units manufactured with the same upgrades as tested specifications. two -wide /mulled units are certified for the same Design b Units tested are manufactured with Warm -Edge I spacer system. Pressure Rating. f Units require upgraded pivot pins. HOTLINE: 1- 800 - 538 -8836 www.weathershield.com FAX: 1- 800 - 390 -1225 (Revised 04 -07) archservices @weathershield.com AIR INFILTRATION WATER STRUCTURALTEST DESIGN CERTIFIED cfm/ft2 [L/s•m�] PERFORMANCE psf [Pa] PRESSURE psf [Pa] PRESSURE UNIT DESIGN RATING PRESSURE Actual Allowable Actual Required Actual Required UNIT STYLE EXTERIOR UNIT SIZE psf [Pa] RATING 32 x 32 0.26 0.30 7.50 7.50 +75.0/ -82.5 75.0 +50.0 /-55.0 H-R50 f [0.123] 10.1421 1359] [359] [ +3591 / -3950] [35911 1+2394/-2633] 30 x 32 Twin 0.15 0.30 7.50 6.75 +67.5 / -75.0 67.5 +45.0 / -50.0 H -R45 f, k Wood [0.071 ] [0.1421 [359] [323] [ +3232 / _3591] [3232] [ +2155 / -23941 Brick 40 4u Twin 0.16 0.30 4.50 4.50 +45.0 /- 45.0 45.0 +30.0 / -30.0 H- LC.301; x [0.07611 [0.1421 [215] [2151 [ +2155 / -2155] 121551 [ +1436 / -14361 40 x 45 0.10 0.30 8.25 4.50 +45.0 / -45.0 45.0 +30.0 / -30.0 H -LC30 [0.047] [0.142] [395] [215] [ +2155 / -2155] [21551 1+1436/-1436) 32 x 32 0.23 0.30 7.50 6.00 +60.0 / -60.0 60.0 +40.0 / -40.0 H -LC40 [0.109] [0.142] [3591 [287] [ +2873 / -2873] [28731 [ +1915/-19151 Double -Hung Tilt b 32 x 32 0.23 [0.109] 0.30 [0.142] 7.50 [3591 7.50 [359] +75.0 / 90.0 [ +3591 / -43091 75.0 [3591 ] +50.0 / 60.0 [ +2394 / 28731 H -LC50 f 40 x 4Q Twin 0.18 0.30 6.75 4.50 +45.0 / -52.5 45.0 +30.0 / -35.0 H -LC30 k Aluminum [0.085] [0.142] [323] 12151 [ +2155! -2514] [2155] [ +1436/ -1676] Clad 38 x 92 Oriel 0.17 0.30 6.00 6.00 +60.0 / -67.5 60.0 +40.0 / -45.0 H -LC40 (Jamb Size) [0.080] [0.142] [287] [287] [ +2873/-32321 [2873] [ +1915 / -21551 30 x 32 Twin 0.18 0.30 8.25 7.50 +75,0 / -75.0 75.0 +50.0 / -50.0 H -R50 f, k [0.085] [0.142] [395] [359] [ +3591 / -3591] 135911 1 +2394 / -2394] 40 x 45 0.16 0.30 8.25 3.75 +37.5 / -37.5 37.5 +25.0 / -25.0 H -LC25 [0.076] [0.142] [395] [180] [ +1796/ -17961 [1796] [ +1197/ -1197) 70 x 8fl 0.01 0.30 6.75 6.75 +67.5 / -82.5 67.5 +45.0 / -55.0 F -C45 Wood 10.0051 [0.1421 [3231 [323) 1+3232/ -3950] [3232] 1+2155/-26331 Brick Double -Hung Tilt Picture Mould 101 x 65 0.01 0.30 7.50 6.75 + 67.5 / -67.5 67.5 +45.0 / -45.0 F -C45 Center b [0.005] [0.142] [3591 [323] [ +3232 / -3232] [3232] [ +2155 / -21551 Aluminum 102 x 65 0.09 0.30 7.50 4.50 +45.0 / -60.0 45.0 +30.0 / -40.0 F -C30 8 Clad 10.0421 [0.1421 [359] [215] [ +2155/ -2873] [2155] [ +1436 / -19151 Wood Brick 71 x 49 0.01 0.30 7.50 7.50 +97.5 / -97.5 75.0 +65.0 / -65.0 F -R50 Mould [0.005] [0.1421 [359] [359] [+4668/-4668] [3591 ] 1+3112 / -31121 Double -Hung Tilt Transom b Aluminum 71 x 46 0.06 0.30 7.50 7.50 + 105.0 / -97.5 75.0 +70.0 J -65.0 F -R50 Clad 10,0281 10.1421 [359] [359] [ +5027 / -46681 135911 [ +3352 / -3112] Wood Brick 96 x 60 0.01 0.30 12.00 11.25 +112.5/ -112.5 112.5 +75.0/ -75.0 F -LC75 Mould [0.0051 [0.1421 [575] [539] [ +5387 / -5387] [5387] [ +3591 / -35911 96 x 60 0.01 0.30 12.00 11.25 +112.5 /- 112.5 112.5 +75.0 / -75.0 F -LC75 Direct -Seth [0.005] 10.142] [575] (539] [ +5387 / -5387] [5387] [ +3591 / -3551] Aluminum 72 x 72 0.01 0.30 12.00 13.50 +135.0 / -135.0 135.0 +90.0 / -90.0 F -C90 5 Clad [0.005] [0.142] [575] [646] [ +6464 / -6464] [6464] [+4309/-43091 103 x 84 0.01 0.30 12.00 6.75 +67,5 / -67.5 67.5 +45.0 / -45.0 F -HC45 9 [0.005] [0.142] [575] [323] [ +3232 / -32321 [3232] [ +2155 / -2155] a Units tested at laboratory in accordance with ANSI /AAMA/NWWDA 9 Units require tempered glass. 101/1.5. 2 -97 and AAMA/WDMA/CSA 101/1.5. 2/A440 -05 test k Single units manufactured with the same upgrades as tested specifications. two -wide /mulled units are certified for the same Design b Units tested are manufactured with Warm -Edge I spacer system. Pressure Rating. f Units require upgraded pivot pins. HOTLINE: 1- 800 - 538 -8836 www.weathershield.com FAX: 1- 800 - 390 -1225 (Revised 04 -07) archservices @weathershield.com Thermal Performance Data` DOUBLE HUNG TILT - ALUMINUM CLAD a Total Unit Calculations U- & R- Values are derived from computer simulations using the WINDOW 4.1 and FRAME 4.0 programs. Simulations are then verified by testing in accordance with bNFRC 100 -97. Center of Glass Calculations U- & R- Values are calculated using the currently approved Window Program, Windows and Daylight Group, Lawrence Berkeley Laboratory. All calculations based on center of glass values for insul units under standard ASHRAE winter conditions with 0 °F [ -17 °C] outdoor and 70 °F [21'C] indoor temperatures along with a 15 mph [24.14 km /h] outside wind. Edge effects and window. system frame effects have not been considered. 184 ENERGY STAR performance criteria is based on total unit Residential NFRC sizes: Climate U -Value SHGC N= Northern < =0.35 No Requirement C= Central S= Southern d Simulated Divided Lite units are calculated with 3/16" grilles in airspace. The effectiveness of an inert gas will be eliminated in window and door products ordered and /or manufactured with capillary tubes. U- Values for units manufactured with an inert gas will be simulated with air in the airspace. www.weathershield.CO "I GLAZING OPTIONS RESIDENTIAL NFRC SIZE 36" x 60" [914mm x 1524mm] TOTAL UNIT CALCULATIONS' RESIDENTIAL NFRC SIZE 36" x 60" [914mm x 1524mm] CENTER OF GLASS CALCULATIONSb Product Type Glazing Thickness Glazing Type U- Value R- Value Solar Heat Gain Co- efficient Visible Light Transmittance U- Value R- Value Solar Heat Gain Co- efficient Visible Light Transmittance Energy Star` 5/8" Insul 0.54 1.85 0.55 0.56 0.50 2.00 0.76 0.81 5/8" Insul w /Argon Gas 0.52 1.92 0.55 0.56 0.47 2.13 0.76 0.81 5/8" Insul Low E' 0.42 2.38 0.31 0.49 0.30 3.33 0.41 0.72 S without 5/8„ Insul Low E' w /Argon Gas 0.39 2.56 0.31 1 0.49 1 0.25 1 4.00 1 0.41 1 0.72 C, S Grilles 5/8" Insul Low E Sun 145 0.43 2.33 0.27 0.31 0.33 3.03 0.35 0.45 S 5/8" Insul Low E Sun 145 w /Argon Gas 0.40 2.50 0.27 0.31 0.28 3.57 0.35 0.45 C, S 5/8" Insul Value R4 0.39 2.56 0.29 0.43 0.24 4.17 0.37 0.63 C, S 5/8" Insul Value R5 0.37 2.70 0.29 0.43 0.22 4.55 0,37 0.63 C, S 5/8" Insul 0.55 1.82 0.50 0.50 0.50 2.00 0.76 5/8" Insul w /Argon Gas 0.53 1.89 0.50 0.50 0.47 2.13 0.76 With Grilles in 5/8" Insul Low E' 0.44 2.27 0.28 0.44 0.30 3.33 0.41 10.72S Airspace 5/8„ Insul Low E' w /Argon Gas 0.41 2.44 0.28 0.44 0.25 4.00 0.41 5 /8" Insul Low E Sun 145 0.45 2.22 0.25 0.27 0.33 3.03 0.35 . 5/8" Insul Low E Sun 145 w /Argon Gas 0.41 2.44 0.25 0.27 0.28 3.57 0.35 0.45 S 5/8" Insul 0.63- 1.59 0.50 0.50 0.50 2.00 0.76 0.81 5/8" Insul w /Argon Gas 0.61 1.64 0.50 0.50 0.47 2.13 0.76 0.81 5/8" Insul Low E' 0.54 1.85 0.28 0.44 0.30 3.33 0.41 0.72 S True 5/8" Insul Low E' w /Argon Gas 0.52 1.92 0.28 0.44 0.25 4.00 0.41 0.72 S Divided Lite 5/8" Insul Low E Sun 145 0.54 1.85 0.25 0.27 0.33 3.03 0.35 0.45 S 5/8" Insul Low E Sun 145 w /Argon Gas 0.52 1.92 0.25 0.27 0.28 3.57 0.35 0.45 S 5/8" Insul Value R4 0.51 1.96 0.26 0.39 0.24 4.17 0.37 0.63 S 5/8" Insul Value R5 0.50 2.00 0.26 0.39 0.22 4.55 0.37 0.63 S 5/8" Insul 0.55 1.82 0.50 0.50 0.50 2.00 0.76 0.81 5/8" Insul w /Argon Gas 0.53 1.89 0.50 0.50 0.47 2.13 0.76 0.81 Simulated Divided 5/8" Insul Low E' 0.44 2.27 0.28 0.44 0.30 3.33 0.41 0.72 S Lited 5/8" Insul Low E' w /Argon Gas 0.41 2.44 0.28 0.44 0.25 4.00 0.41 0.72 S 5/8" Insul Low E Sun 145 0.45 2.22 0.25 0.27 0.33 3.03 0.35 0.45 S 5/8" 1 Insul Low E Sun 145 w /Argon Gas 0.41 1 2.44 0.25 1 0.27 0.28 3.57 1 0.35 1 0.45 S a Total Unit Calculations U- & R- Values are derived from computer simulations using the WINDOW 4.1 and FRAME 4.0 programs. Simulations are then verified by testing in accordance with bNFRC 100 -97. Center of Glass Calculations U- & R- Values are calculated using the currently approved Window Program, Windows and Daylight Group, Lawrence Berkeley Laboratory. All calculations based on center of glass values for insul units under standard ASHRAE winter conditions with 0 °F [ -17 °C] outdoor and 70 °F [21'C] indoor temperatures along with a 15 mph [24.14 km /h] outside wind. Edge effects and window. system frame effects have not been considered. 184 ENERGY STAR performance criteria is based on total unit Residential NFRC sizes: Climate U -Value SHGC N= Northern < =0.35 No Requirement C= Central S= Southern d Simulated Divided Lite units are calculated with 3/16" grilles in airspace. The effectiveness of an inert gas will be eliminated in window and door products ordered and /or manufactured with capillary tubes. U- Values for units manufactured with an inert gas will be simulated with air in the airspace. www.weathershield.CO "I ' �..,dersen Windows - Printed Quote /Long Andersen GUERRY LUMBER Andersen E 123 W 44TH STk , g ; SAVANNAH,GA 31405 912- 232 -3128 QUOTE: 000016 QUOTE DATE: 07/20/2006 CUSTOMER: CELL: PO #: 22393MC SALESREP: Mike Cochran PROJECT: MATHEWS CUSTOM HOMES TERMS: PICKUP /DELIVERY: Delivery CSR Name: Billing Information CONTACT: PHONE: FAX: ADDRESS: Shipping Information CONTACT: PHONE: FAX: ADDRESS: CK4PduL0►y163 I oo(1,s PRINT DATE 08/02/2006 QUOTE: 000016 Print Date: 08/02/2006 Page 1 Of 3 iQ Version: iQ6.1 Line Item #: 0001 Line Item Qty: 1 Initial: Location: RO Size = 5'0" W x 6' 11" H Unit Size = 4' 11 1/4" W x 6' 10 3/8" H 400 Series, FWG Double -wide Units Unit Code /Item Size: FWG50611 Operation /Handing: SR 1— Exterior Color: White Interior Color: Clear Pine Glass Type: High Performance Low -E4 Tempered Glass Insect Screens: Gliding Insect Screen, White DP Upgrade: Clear Pine, Factory Applied Trimset Finish: Tribeca - White Exterior / Tribeca - Stone Interior Auxiliary Lock Finish: Stone Threshold: Maple Sill Support: Yes QUOTE: 000016 Print Date: 08/02/2006 Page 2, Of 3 Comments: — FWG \PS \NL -Labor for Two -panel frame assembly- A \W, Non- Factory Direct Qty Part Num Item Size Description " 1 2565024 FWG50611SR Frame, SR Handing, White /Clear Pine 1 2565903 FWG26611 Stationary Panel, White /Clear Pine, High Performance Low -E4 Tempered Glass 1 2565941 FWG26611 Operating Panel, White /Clear Pine, High Performance Low -E4 Tempered Glass, with DP Upgrade 1 2565309 PD26611 Gliding Insect Screen, White 1 2562032 -- - - - - -- Hardware Trim Set, GD, Exterior, 2 Panel, Tribeca - White 1 2562078 -- - - - - -- Hardware Trim Set, GD, Interior, 2 Panel, Tribeca - Stone 1 1997220 -- - - - - -- Lock, Auxiliary, GD, Stone 1 1207058 5 Threshold, Maple w /Screws $ 1 1997054 PD50 Support, Sill, Aluminum (Neutral Gray) $ 1 0000000 -- --- - -- FWG \PS \NL -Labor for Two -panel frame $I assembly- A \W Non- Factory Direct Adjustment QUOTE: 000016 Print Date: 08/02/2006 Page 2, Of 3 Line Item #: 0004 Line Item Qty: 2 Initial: Location: RO Size = 5'0 "Wx6'11 "H Unit Size = 4' 11 1/4" W x 6' 10 3/8" H 4 Qty Part Num Item Size 1 2565023 FWG50611LS 1 2565903 FWG26611 1 2565941 FWG26611 1 2565309 PD26611 1 2562032 - - - - - -- 1 2562078 - - - - - -- 1 1997220 -- - - - - -- 1 1207058 5 1 1997054 PD50 1 0000000 -- - - - - -- SUBMITTED BY: ACCEPTED BY: DATE: 400 Series, FWG Double -wide Units Unit Code /Item Size: FWG50611 Operation /Handing: LS Exterior Color: White Interior Color: Clear Pine Glass Type: High Performance Low -E4 Tempered Glass Insect Screens: Gliding Insect Screen, White DP Upgrade: Clear Pine, Factory Applied Trimset Finish: Tribeca - White Exterior / Tribeca - Stone Interior Auxiliary Lock Finish: Stone Threshold: Maple Sill Support: Yes Comments: -- FWG \PS \NL -Labor for Two -panel frame assembly- A \W Non- Factory Direct Description Total Price Frame, LS Handing, White /Clear Pine Stationary Panel, White /Clear Pine, High Performance Low -E4 Tempered Glass Operating Panel, White /Clear Pine, High Performance Low -E4 Tempered Glass , with DP Upgrade Gliding Insect Screen, White $ Hardware Trim Set, GD, Exterior, 2 Panel, Tribeca $ - White Hardware Trim Set, GD, Interior, 2 Panel, Tribeca $ - Stone Lock, Auxiliary, GD, Stone $ Threshold, Maple w /Screws $ Support, Sill, Aluminum (Neutral Gray) $ FWG \PS \NL -Labor for Two -panel frame $ assembly- A \W Non- Factory Direct Adjustment ** All graphics as viewed from the exterior. QUOTE: 000016 Print Date: 08/02/2006 SUBTOTAL TAXES( 6.000 %) GRAND TOTAL Page 3: Of 3 iQ Versi, ormance Data Total r n windows and patio doors meet or exceed the following standards: WDMA,- I.S. -2, W.D.M.A -I.S. 4 (WDMA license No. 129), Hallmark certified. Independent testing laboratories have performed all required tests on selected sizes. nce with these standards is confirmed by ongoing testing in Andersen Laboratories. These products are covered by one or more of the following patents: 4,999,950; 5,595,409; 5,775,749; 6,055,786; 5,544,450; 5,566,507; 45; 5,097,629; 5,740,632; 5,199,234; D312,565; D397,604; and D417,831. Other patents pending. Series Windows )rsen° Product Type Without Grilles HP HP Sun Low -E Low -E HP Low -E HP Sun Low -E Iment 48" size U- Factor' SHGCZ VP 0.33 0.33 0.53 0.35 0.24 0.29 0.34 0.36 0.30 0.22 0.48 0.26 ng 24" size U- Factor' SHGCZ VP 0.33 0.32 0.52 0.35 0.24 0.28 0.34 0.36 0.30 0.22 0.47 0.26 lment/Awning ire Window 48" size U- Factor' SHGCZ `v'^ 0.30 0.36 0.59 0.32 0.26 0.32 0.32 0.34 0.33 0.24 0.53 0.29 dwrigW ale -Hung 60" size U- Factor SHGCZ VP 0.33 0.32 0.51 0.35 0.24 0.28 0.34 0.36 0.29 0.22 0.46 0.25 dwrighr ire Window 48" size U- Factor' SHGCZ VP 0.30 0.33 0.54 0.32 0.24 0.29 0.32 0.34 0.31 0.22 0.48 0.26 dwright® som 48" size U- Factor' SHGCZ VP 0.30 0.35 0.57 0.32 0.25 0.31 0.32 0.34 0.32 0.23 0.51 0.28 (Nash ble -Hung 60" size U- Factor' SHGCZ VP 0.34 0.32 0.51 0.36 0.24 0.28 0.35 0.35 0.29 0.22 0.45 0.25 Wash ble -Hung Picture 48" size U- Factor SHGCZ VP 0.33 0.35 0.56 0.35 0.25 0.30 0.35 0.37 0.32 0.24 0.50 0.27 Wash ble -Hung Transom 48" size U- Factor' SHGCZ VP 0.33 0.35 0.56 0.35 0.25 0.31 0.34 0.36 0.32 0.23 0.50 0.27 ing Window 36" size U- Factor SHGCZ VP 0.36 0.30 0.46 0.38 0.23 0.25 0.38 0.39 0.28 0.21 0.41 0.22 tical Window 48" size U- Factor SHGCZ VP 0.30 0.36 0.59 0.32 0.26 0.32 0.32 0.34 0.33 0.24 0.53 0.29 le Top° ament 48" size U- Factor SHGCZ VP 0.30 0.36 0.59 0.32 0.26 0.32 0.32 0.34 0.33 0.24 0.53 0.29 le/Oval 48" size U- Factor' SHGCZ VP 0.30 0.36 0.59 0.32 0.26 0.32 0.32 0.34 0.33 0.24 0.53 0.29 i Windows :48" size U- Factor' SHGCZ VP 0.31 0.36 0.59 0.33 0.26 0.32 0.32 0.34 0.33 0.24 0.53 0.29 iframe® ( 48" size U- Factor' SHGCZ VP 0.30 0.36 0.59 0.32 0.26 0.32 0.32 0.34 0.33 0.24 0.53 0.29 ngline "Window c 48" size U- Factor SHGCZ VP 0.34 0.35 0.55 0.36 0.26 0.30 0.36 0.38 0.32 0.24 0.50 0.27 Tempered r light (48" size U- Factor SHGCZ VP 0.56 0.41 0.68 0.58 0.30 0.37 0.55 0.57 0.40 0.29 0.66 0.36 Ling F Window (48" size U- Factor' SHGCZ VP 0.53 0.38 0.62 0.55 0.28 0.34 0.53 0.55 0.37 0.27 0.61 0.33 ;ionary F Window ( 48" size U- Factor SHGCZ VP 0.53 0.39 0.64 0.55 0.28 0.35 0.53 0.54 1 0.38 0.27 1 0.62 0.34 400 Series Doors Andersen® Product Type Tempered w/o Grilles HP HP Sun Low -E Low -E r HP Low -E HP Sun Low -E Frenchwood° Gliding Patio Door 72" x 82" size U- Factor' SHGCZ VP 0.33 0.29 0.44 0.35 0.21 0.24 0.35 0.36 0.26 0.20 0.39 0.21 Frenchwooda Hinged Patio Door 38" x 82" size U- Factor' SHGCz VP 0.33 0.27 0.41 0.34 0.20 0.22 0.34 0.36 0.25 0.19 0.36 0.20 Frenchwood® Outswing Patio Door 38" x 82" size U- Factor' SHGCZ VT' 0.34 0.27 0.41 0.36 0.20 0.22 0.36 0.37 0.25 0.19 0.36 0.20 Frenchwood® Patio Door Sidelight 16" x 82" size U- Factor' SHGCZ VP 0.35 0.20 0.27 0.36 0.15 0.15 0.35 0.36 0.19 0.15 0.26 0.14 Frenchwood® Patio Door Transom 38'x 14" size U- Factor SHGCZ VP 0.34 0.16 0.20 0.35 0.13 0.11 0.34 0.35 0.15 0.12 0.19 0.10 200 Series Windows & Doors Andersen® Product Type Without Grilles Clear Dual -Pane Low -E Clear Dual -Pane Low -E Casement 24" x 48" size U- Factor SHGCZ VP 0.48 0.57 0.59 - - - 0.49 - 0.52 - 0.54 - Awning 48" x 24" size U- Factor' SHGCZ VP 0.48 0.56 0.58 - - - 0.49 - 0.52 - 0.53 - Tilt -Wash Double -Hung 36" x 60" size U- Factor' SHGCZ VP 0.49 0.56 0.58 0.34 033 0.51 0.50 0.35 0.51 0.30 0.52 0.46 Narroline® Double -Hung 36" x 60" size U- Factor' SHGCZ VP 0.50 0.58 0.60 0.35 0.33 0.53 0.50 0.36 0.52 0.31 0.53 0.47 Narroline® Transom 48"x 48" size U- Factor SHGCZ VP 0.47 0.59 0.62 0.31 0.34 0.55 0.48 0.33 0.54 0.31 0.56 0.49 Gliding Window 60" x 36" size U- Factor' SHGCZ VP 0.50 0.57 0.58 0.35 0.33 0.52 0.50 0.36 0.51 0.30 0.52 0.46 Med,Transom, Circle Top 48" x 48" size U- Factor' SHGCZ VP 0.47 0.60 0.62 0.31 0.34 0.55 0.48 0.33 0.54 0.32 0.56 0.49 Narrolind' Gliding Patio Door 72" x 82" size U- Factor' SHGCZ VP Tempered w/o EGnIl 0.49 0.60 0.62 r • • r 0.50 0.35 0.54 0.32 0.56 0.49 Perma- Shield' Gliding Patio Door 72" x 82" size U- Factor' SHGCz VP 0.47 0.60 0.62 0.31 0.34 0.56 0.48 0.33 1 0.54 0.32 1 0.56 0.50 Please contact your Andersen supplier for performance values on products that include patterned glass. Skylight and roof window values are based upon NFRC 2001 procedures rated at a 20 degree angle. Grilles- Finelight or Full Divided light. "High - Performance" (HP Low -E) and "High - Performance Sun" (HP Sun) are Andersen trademarks for "Low -E" glass. 1 1.1-Factor defines the amount of heat loss through the total unit in BTU /hr sq. ft'. "F. The lower the value, the less heat is lost through the entire product. 2 Solar Heat Gain Coefficient (SHGC) defines the fraction of solar radiation admitted through the glass both directly transmitted and absorbed and subsequently released inward. The lower the value, the less heat is transmitted through the product 3 Visible Transmittance (VT) measures how much light comes through a product (glass and frame). _ The higher the value, from 0 to 1, the more daylight the product lets in over the product's total unit area. Visible Transmittance is measured over the 380 to 760 nanometer portion of the solar spectrum. This data is accurate as of August 2, 2004. Due to ongoing product changes, updated test results, or new industry standards, this data may change over time. 255 DATE ISSUED: 08 -31 -2006 WORK DESCRIPTION: WORK LOCATION: OWNER NAME ADDRESS CITY, ST, ZIP CONTRACTOR NAME ADDRESS CITY STATE ZIP FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE TOTAL FEE'S CHARGED PROPERTY IDENTIFICATION # PROJECT VALUATION CITY OF TYBEE ISLAND BUILDING PERMIT REPLACE WOOD /WINDO «'S /DOOR 4 MARSH CREEK COVE MARY E. ADAMS PO BOX 1900 TYBEE ISLAND GA 313281900 K & D CUSTOM BUILDER PO BOX 30422 SAVANNAH GA 31410 P $ 175.00 $20,000.00 PERMIT #: 060468 TOTAL BALANCE DUE: $ 175.00 It is understood that if this permit is granted the builder will at all times comply with the zoning, subdivision, flood control, building, fire, soil and sedimentation, wetlands, marshlands protection and shore protection ordinances and codes whether local, state or federal, including all environmental laws and regulations when applicable, subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. Signature of Building Inspector or Authorized Agent: P. O. Box 2749 - 403 Butler Avenue, Tybee Island, Georgia 31328 (912) 786-4573 - FAX (912) 786 -5737 www.cityoftybee.org CITY OF TYBEE ISLAND, GEORGIA APPLICATION FOR BUILDING PERMIT d lam} v (0 - C) 4 (�R acmp�S F Location:y�G'c��= PIN # �1 AMRFCC TFT PPPT(IATP Owner ij-w¢ l,¢d g,j C S - - - -- -- - - Architect []/Renovation ❑ Minor Addition or Engineer ❑ Single Family ❑ Substantial Addition Building ❑ Commercial ❑ Multi - Family Contractor ❑ Repairs - 5;X,11, 0 Demolition (Check all that apply) ❑ New Construction []/Renovation ❑ Minor Addition ❑ Duplex ❑ Single Family ❑ Substantial Addition ❑ Residential ❑ Commercial ❑ Multi - Family ❑ Footprint Changes ❑ Repairs ❑ Demolition ❑ Other Estimated cost of Construction: $ . 00 C 41m ' e (1) Wood Fr 2) Wood & Masonry (3) Brick N7-- r Proposed i Remarks: Of (Enter appropriate number) (4) Masonry (6) Other (please specify) (5) Steel & Masonry ATTACH A COPY OF THE CERTIFIED ELEVATION SURVEY OF LOTS and complete the following information based on the construction drawings and site plan: # Units Lot Area # Off - street parking spaces Trees located & listed on site plan Access: Driveway Setbacks: Front # Bedrooms Living space (total sq. ft.) With culvert? Rear # Bathrooms With Swale? Sides (L) (R) # Stories Height Vertical distance measured from the average adjacent grade of the building to the extreme high point of the building, exclusive of chimneys, heating units, ventilation ducts, air conditioning units, elevators, and similar appurtances. During construction: On -site restroom facilities will be provided through 66,%C4 On -site waste and debris containers will be provided by Construction debris will be disposed by at by means of I understand that I must comply with zoning, flood damage control building fire shore protections and wetlands ordinances FEMA regulations and all applicable codes and regulations. I understand that the lot must be staked out and that the stakes will be inspected to ensure that the setback requirements are met. I understand also that a certified plot plan showing elevation must be attached to this application and that an as-built elevation certification is due as soon as the habitable floor level is established. Drainage: I realize that I must ensure the adequacy of drainage of this property so that surrounding property is in no way adversely affected. I accept responsibility for any corrective action that may be necessary to restore dra' impaired by this permitted construction. Date:'/ 4Cy Signature of Applicant: Note: A permit normally takes 7 to 10 des to process. --------------------------------------------------------------------------------------------- The following is to be completed by City personnel: Zoning certification Approved rezoning/variance? Street address and number: New Is it in compliance with City map? If not, has street name and/or number been reported to MPC? FEMA Certification attached State Energy Code Affidavit attached Utilities and Public Works: Describe any unusual finding(s) Access to building site Distance to water main tap site Distance to sewer stub site Water meter size Storm drainage _ Approvals: Zoning Administrator Code Enforcement Officer Water /Sewer Storm/Drainage Inspections City Manager NFIP Flood Zone Existing Signature Date FEES Permit I Inspections (4 Water Tap Sewer Stub Aid to Const. TOTAL