HomeMy Public PortalAboutOrd. 1668ORDINANCE NO. 1668 AN ORDINANCE OF THE CITY OF LYNWOOD AMENDING CHAPTER 11 OF THE LYNWOOD MUNICIPAL CODE, BUILDING AND HOUSING BY AMENDING SECTION 11 -1 (BUILDING CODE), SECTION 11 -6 (ELECTRICAL CODE), SECTION 11 -9 (PLUMBING CODE), SECTION 11 -10 (MECHANICAL CODE), SECTION 11 -18 (APPENDIX CHAPTER Al OF THE BUILDING CONSERVATION CODE), SECTION 11 -21 (RESIDENTIAL CODE) AND SECTION 11 -22 (GREEN BUILDING STANDARDS CODE) WHEREAS, Section 17958 of the California Health and Safety Code requires the local adoption of the latest model codes, which have been adopted at the State level, and requires these regulations become effective six months after the State adoption and publication of the codes; and WHEREAS, the State published these codes on July 1, 2013, and the codes will become effective January 1, 2014; and .. WHEREAS, these State mandated codes and related materials are used by the Building Inspectors, Code Enforcement Officers, City Clerk, City Attorney, City Prosecutor, Designers, Architects, Engineers, Developers, Contractors and the general public; and WHEREAS, incorporating the 2013 Edition of the California Building Standards Codes will keep the City of Lynwood in compliance with State law; and WHEREAS, the City's building regulations remain consistent with those of the State, providing minimum standards to safeguard life or limb, health, property and public welfare. NOW THEREFORE, THE CITY COUNCIL OF THE CITY OF LYNWOOD DOES HEREBY ORDAIN AS FOLLOWS: Section 1. Chapter 11 Building and Housing, Section 11 -1 (Building Code), Section 11 -1.1 (Building Code Adopted) and Section 11 -1.2 (Amendments to the Building Code) of the Lynwood Municipal Code are hereby amended to read as follows: 11 -1 Building Code 11 -1.1 Building Code Adopted: Except as provided herein, the 2013 edition of the California Building Code, which is based on the 2012 International Building Code, as promulgated and published by the International Code Council, and including any California amendments or adopted appendices, is hereby adopted by reference as though fully set forth herein, and shall constitute and is hereby established as "The Building Code of the City of Lynwood" ( "building code" herein). A copy of the 2013 edition of the California_; Building, Code has been deposited in the office of the City Clerk and shall at all times be maintained by the City Clerk for use and examination by the public. 11 -1.2 Amendments To The Building Code: Section 11 -1.2 (a) Building official.is hereby amended to read as follows: The term building official in Chapter 1, Divisional, Section 103 of the California Building. Code shall be the building and safety manager of the City of Lynwood. Section 11. 1.2 (b) Board of appeals is hereby amended to read as follows The board of appeals in Chapter 1, Division II; Section 113.1 of the ,-California Building Code shall be the City Council of the City of Lynwood. Chapter 1, Division II, Section 113.3 of the California Building Code is hereby deleted. Section 11. 1.2 (c) is hereby amended to read as follows:'. Section 116 of the California Building Code, entitled "Unsafe Structures- and Equipment is amended in its entirety to read as follows: Buildings, structures or existing ,equipment that are or hereafter become, unsafe, insanitary or deficient because of inadequate means of egress facilities, inadequate light and ventilation, or which constitute a fire hazard, or are otherwise dangerous to•.,human life or the public welfare, or that involve illegal or improper occupancy or, inadequate maintenance, shall be deemed an unsafe condition. All such unsafe buildings, structures, equipment or ;appendages. are declared to be public nuisances and shall be abated by repair, rehabilitation, demolition ;or,removal in accordance with the procedures set forth in Section 11 -13 of this chapter 11. ( "Abatement Of Dangerous Buildings Code "), or the ,procedures applicable: to the abatement of nuisances, or such alternate. procedures .as may have been or, as, may be adopted by the legislative body. As an alternative, the building, official, or "other employee or official of the city, as designated by the legislative body, may institute any other appropriate action to prevent, restrain, correct or abate the violation. Section 11 -1.2 (e) is hereby amended to read as follows: Chapter 1, Division II, Section 109.6 of the California Building Code is hereby amended by adding the following: All refunds of fees that are authorized by the building official are subject to final' approval by the city manager. Section 11 -1.2 (f) is hereby amended to read as follows: Subsection 1501.1 ( "Scope ") of Section 1501 ( "General') of Chapter 15 ( "Roof Assemblies And 'Rooftop Structures ") of the California Building Code is amended by adding the following language to the first sentence thereof: Notwithstanding any provisions to the contrary contained in the Lynwood municipal code or the California building code, all roof coverings must consist of a fire- retardant class A roof covering. Findings of Climatic conditions: The City of Lynwood is located in an area subject to climatic conditions with long periods of low humidity and hot weather, combined with unpredictable seasonal high winds (Santa Ana wind condition), resulting in increased exposure to fire risk. This creates an environment that is conducive of rapidly spreading fires. Control of rapidly spreading fires requires rapid response from Fire Departments. However, with the time that is required for the Fire Department to deal with potential obstacles from the wind, such as fallen trees, street lights and utility poles, in addition to the time required to climb stairs or obstacles, the ability to respond rapidly and in a timely manner is impaired. Therefore the need for a class A roof to reduce the possibility of fire and the spread of these fires if they start. The Lynwood City Council hereby adopts this finding of local condition for this item. Section 11 -1.2 (g) is hereby amended to read as follows: Repealed. Section 11 -12 (h) is hereby amended to read as follows: The 2013 California Building code is hereby amended by adopting the structural amendments as published by the Los Angeles Regional Uniform Regional Code Program, Part I - International Code Council - Los Angeles Basin Chapter published September 5, 2013 (exhibit 1). Findings: Findings of local conditions indicated under each item in the above document are hereby adopted as the Lynwood City Council findings of local conditions. Section 2. Chapter 11 Building and Housing, Section 11 -6 (Electrical Code) and 11 -6.1 (Electrical Code Adopted) of the Lynwood Municipal Code are hereby amended to read as follows: 11 -6 Electrical Code 1.1 -6.1 Electrical Code Adopted: Except as provided herein, the 201,3 edition of the California Electrical Code, ;which -is based on the 2011 National Electrical Code, as promulgated and .published by the National Fire Protection Association, Inc., including :any California amendments and adopted annexes thereof,, is hereby adopted by reference as though fully set forth herein, and shall constitute and is hereby established as "The Electribal Code'of the. City of Lynwood" ( "electrical code" herein). A copy of the 2013 edition of .the' California Electrical Code has been deposited in the office of the City Clerk and shall at all ~times be maintained by the City Clerk for use and examination by the public. Section 3. Chapter 11 Building and Housing, Section '11= 9,(Plumbing Code) and 11 -9.1 (Plumbing Code Adopted) of the Lynwood. Munioipal'Code are "hereby Amended to read as follows: ' 11 -9 Plumbing Code 11-9.1 Plumbing Code Adopted:, Except as provided herein, the 2013 edition of the California Plumbing Code, which is based on the 2012 Uniform Plumbing Code, as promulgated and published; by the International Association of Plumbing and Mechanical Officials; including any California amendments and adopted appendices thereof, is hereby adopted by reference as though fully set forth herein, and shall constitute and is hereby established` as "The. Plumbing Code of the City of Lynwood" ( "plumbing code" herein). A copy of 'the 201!3 edition of the California Plumbing Code has been deposited in the office of the City Clerk and shall at all times be maintained by the City Clerk for use .And examination -by the public. Section 4. Chapter 11 _ Building. and Housing, Section 11 -10 (Mechanical Code) and 11 -10.1 (Mechanical Code Adopted) of the Lynwood Municipal Code are hereby amended to read as follows: . 11 -10 Mechanical Code 11 -10.1 Mechanical Code Adopted: Except as provided herein, the -2013 edition of the California Mechanical Code, which is based on the 2012 Uniform Mechanical. Code, as promulgated and published Eby the. International Association of Plumbing and Mechanicai Officials, including any, California amendments and adopted appendices thereof, is hereby adopted by reference. as though fully set forth herein, and shall constitute and is hereby.establishec7 'as "The Mechanical Code of the City of Lynwood" ( "mechanical code" herein). A copy,,of the 2013 edition of the California Mechanical Code has been deposited 'in the office of the City Clerk and shall at all times be maintained by the City Clerk for use and examination by the public._ Section 5. Chapter 11 Building and Housing, Section 11 -18 (Appendix Chapter Al of the California Building Conservation Code) and 11 -18.1 (Appendix Chapter Al of the California Building Conservation Code Adopted) of the Lynwood Municipal Code are hereby amended to read as follows: 11 -8 Appendix Chapter Al of the California Existing Building Code 11 -18.1 Appendix Chapter Al of the California Existing Building Code Adopted: Except as hereinafter provided, appendix chapter Al of the California Existing Building Code, as contained in part 10 of title 24 of the California Code of Regulations is adopted by reference and incorporated herein as though fully set forth and shall constitute appendix chapter Al of the existing building code of the city. A copy of that California Existing Building Code has been deposited in the office of the City Clerk and shall be, at all times, maintained by the city clerk for use and examination by the public. Section 6. Chapter 11 Building and Housing, Section 11 -21 (Residential Code), Section 11 -21.1 (Residential Code Adopted) and Section 11 -21.2 (Amendments To The Residential Code) of the Lynwood Municipal Code are hereby amended to read as follows: 11 -21 Residential Code 11 -21.1 Residential Code Adopted: Except as provided herein, the 2013 edition of the California Residential Code, which is based on the 2012 International Residential Code, as promulgated and published by the International Code Council, and including any California amendments or adopted appendices, is hereby adopted by reference as though fully set forth herein, and shall constitute and is hereby established as "The Residential Code of the City of Lynwood" ( "residential code" herein). A copy of the 2013 edition of the California Residential Code has been deposited in the office of the City Clerk and shall at all times be maintained by the City Clerk for use and examination by the public. 11 -21.2 Amendments To The Residential Code: Section 11 -21.2 (a) Building official is hereby amended to read as follows: The term building official in Chapter 1, Division II, Section R103 of the California Residential Code shall be the building and safety manager of the City of Lynwood. Section 11.21.2 (b) Board of appeals is hereby amended to read as follows: The board of appeals in Chapter 1, Division 11, Section R112.1 of the California Residential Code shall be the City Council of the City of Lynwood. Chapter 1, 'Division II, Section R112.3 of the California Residential Code•is' hereby deleted. Section 11.21.2 (c) is hereby amended to read as follows: Chapter 1, Division II, Section 108.5 of the Calif6mial Residential Code C'hereby amended by adding the following: All refunds of fees that are authorized by the building official are subject to final approval by the city manager. Section 11 -21.2 (d) is hereby amended to read, as follows: Subsection R901.1 ("Scope") of Section R901 ( "General ") of Chapter.. 9, ( "Roof Assemblies ") of the California Residential Code is amended by adding the following language to the first sentence: Notwithstanding any provisions to the contrary contained, in the; Lynwood municipal code or the California Residential code, all roof coverings must consist of:,a'fire- retardant class A roof covering. Findings of Climatic conditions: The City of Lynwood is located in an area subject to climatic conditions with long periods of low humidity and hot weather, combined with unp "redictable`seasonal'. high winds (Santa Ana wind condition), resulting in increased exposure' to fire risk. This creates an environment that is. conducive of rapidly spreading .fires. Control of rapidly spreading fires requires rapid response from Fire Departments. However, with the time that is required for the Fire Department to•.deal `with potential obstacles from the wind, such as fallen trees, street lights'-and utility poles, in addition to the time required to climb stairs or obstacles, the ability to respond rapidly and in a timely- manner is impaired. Therefore the need for a class A roof to reduce the possibility of fire and the spread,of these fires if they start. The Lynwood City Council hereby adopts this finding-of local condition for this item. Section 11 -21.2 (e) is hereby amended to read as follows: The 2013 California Residential code is hereby amended by adopting the, structural amendments as published by the' Los. Angeles Regional Uniform Regional' Code Program, Part II - International Code Council - Los Angeles Basin Chapter published September 5, 2013 (exhibit 1). Findings: 4 Findings of local conditions indicated under each item in the above document are hereby adopted as the Lynwood City Council findings of local conditions. Section 7. Chapter 11 Building and Housing, Section 11 -22 (Green Building Standards Code) and 11 -21.1 (Green Building Standards Code Adopted) of the Lynwood Municipal Code are hereby amended to read as follows: 11 -22 Green Building Standards Code 11 -22.1 Green Building Standards Code Adopted: Except as provided herein, the mandatory provisions of the 2013 edition of the California Green Building Standards Code is hereby adopted by reference as though fully set forth herein, and shall constitute and is hereby established as 'The Green Building Standards Code of the City of Lynwood" ( "green code" herein): A copy of the 2013 edition of the California Green Building Standards Code has been deposited in the office of the City Clerk ,and shall at all times be maintained by the City Clerk for use and examination'by the public. Section 8. All prior provisions of the Codes adopted by the his Ordinance are hereby repealed and replaced with the above referenced Codes. Section 9. The adoption of this Ordinance shall fulfill the City of Lynwood's obligation under Section 17958 of the Health and Safety Code to adopt and apply the provisions of the California Building Standards Code to all occupancies within the City. Section 10. This Ordinance shall take effect and be in force on January 1, 2014. Section 11. The City Clerk shall certify as to the adoption of this Ordinance following the City Council's second reading and to cause it to be published as. required by law. First read at a regular meeting of the City Council held on the 1st day of October, 2013 and adopted and ordered published at a regular meeting of said Council on the 15th day of October, 2013. PASSED, APPROVED and ADOPTED this 1 5th day of October, 2013. ATTEST: "7 jo� APPROVED AS FOR FORM:. Fred G lante, City Attorney Sa vad r Alatorre, Mayor APPROVED AS TO CONTENT: Richard N. Warne, Interim City Manager Jonathan Colin, Director Development Services STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) I, the undersigned, City Clerk of the City of Lynwood, do hereby certify that the above and foregoing Ordinance was duly adopted by the City Council of the City of Lynwood at its regular meeting held on the 15th day of October, 2013. AYES: COUNCIL MEMBERS CASTRO, RODRIGUEZ AND ALATORRE NOES: - NONE ABSENT: NONE ABSTAIN: NONE Maria Quinonez, City Clerk STATE OF CALIFORNIA ) COUNTY OF LOS ANGELES ) SANTILLAN -BEAS, MORTON, I, the undersigned, City Clerk of the City of Lynwood, and Clerk of the City Council of said City, do hereby certify that the above and foregoing is a full, true and correct copy of Ordinance No. 1668 in my office and that said Ordinance was adopted on the date and by the vote therein stated. Dated this 15th day of October, 2013. Maria Quinonez, City Clerk (EXHIBIT 1) 2013 EDITION OF THE LOS ANGELES REGION UNIFORM CODE PROGRAM RECOMMENDED TECHNICAL AMENDMENTS TO THE 2013 EDITION OF THE CALIFORNIA BUILDING CODE, CALIFORNIA RESIDENTIAL CODE, AND CALIFORNIA GREEN BUILDING STANDARDS CODE Final Version: September 5, 2013 i;jN4;rilN4lj:ys ICC LOS ANGELES BASIN CHAPTER'S STRUCTURAL CODE COMMITTEE GREEN BUILDING STANDARDS CODE COMMITTEE FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM PREFACE In 1957 our founding members established one of the earliest chapters of the International Conference of Building Officials. Today the Chapter has grown to over eighty -nine Southern California jurisdictions, plus consulting firms and other members of the construction industry. ICBO merged with two other building official organizations to create the International Code Council. The Los Angeles Basin Chapter officially became an ICC Chapter in December 2002. The Los Angeles Basin Chapter has been very active throughout the years in leading an effort to create uniformity of building codes and regulations in the greater Los Angeles region as well as addressing policy issues of interest to building officials and the construction industry. One such effort to promote uniformity of building regulations is through the Los Angeles Regional Uniform Code Program ( LARUCP). The LARUCP program began in July 1999 with the purpose of developing uniform interpretations and handouts to serve as guidelines for building officials, contractors, engineers and architects in the consistent application of the codes. The mission of this program was to minimize the number of, and to develop uniformity in local technical amendments to the California codes for adoption by jurisdictions in the greater Los Angeles region. Leading the efforts to creating uniformity of building codes and regulations within the region are the dedicated members of the Los Angeles County Building and Safety Division, City of Los Angeles Department of Building and Safety, City of Long Beach Building and Safety Bureau, and other jurisdictional members in the greater Los Angeles region. Through the coordination of the ICC Los Angeles Basin Chapter's Structural Code Committee and Green Building Standards Committee, the following regulatory streamlining tasks to be completed are: 1. Create uniformity of building, plumbing, mechanical, electrical, energy efficiency and green codes that can be adopted in most of the jurisdictions in the greater Los Angeles region. 2. Reduces the total number of local technical amendments to the model code in the greater Los Angeles region. 3. Received support from most, if not all, of the 89 jurisdictions in the greater Los Angeles region. 4. Obtain active participation from a majority of the jurisdictions in the greater Los Angeles region in formulating and implementing this program. 5. With construction valuation of over $5 billion in the region, conservatively assuming that this program produces a 1 % construction cost savings, achieve an estimated cost saving of $50 million per year in the greater Los Angeles region. DISCUSSION Sections 13145.3, 17922, 17958 and 18941.5 of the California Health and Safety Code requires that the latest California Building Standards Codes apply to local construction 180 days after they become effective at the State level. The California Building Standards Commission has adopted the 2013 Edition of the California Building Code, California Residential Code, and California Green Building Standards Code. State Law requires that these Codes become effective at the local level on January 1, 2014. Sections 17958.5 and 17958.7 of the California Health and Safety Code requires that local amendments to the California Building Standards Codes and other regulations, including but not limited to, green building standards, be enacted only when an express finding is made that such modifications or changes are reasonably necessary because of local climatic, geological or topographical conditions. 2013 LARUCP Recommended Technical Amendments Page 2 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM The ICC Los Angeles Basin Chapter's Structural Committee and Green Building Standards Committee are recommending that the 2013 Edition of the LARUCP Recommended Amendments contained in this document, some of which continues amendments enacted during the previous code adoption cycle, be considered for local adoption for the following reasons: To protect the community within the greater Los Angeles region from a vast array of fault systems capable of producing major earthquakes and /or climate systems capable of producing major winds, fire and rain related disaster. 2. To ensure and encourage energy efficiency and sustainable practices are incorporated into building designs and constructions. The 2013 Edition of the LARUCP Recommended Amendments have been widely circulated and discussed over the past several months with various local jurisdictional members, SEAOSC Building Code Committee, design professionals in the construction industry, and other interested groups or individuals. The proposed code language along with the reasons and findings are detailed in this document for each of the recommended technical amendments to the California Building Standards Code. STATEMENT ON USE OF DOCUMENT The primary purpose of the ICC Los Angeles Basin Chapter's Committees is to serve and benefit its members. To this end, the Committees provide a forum for the exchange, consideration, and discussion of ideas and proposals that are relevant to the construction industry and the consensus of which forms the basis for the proposed amendments contained in this document. By making available the recommendations in this document, the Los Angeles Basin Chapter's Committees do not insure any jurisdiction using the information it contains against any liability arising from that use. The Committees disclaims liability for any injury to persons or to property, or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on this document. The Committees makes no guaranty or warranty as to the accuracy or completeness of any information provided herein. Any jurisdiction using this document should rely on their own independent judgment and exercise reasonable care in any given circumstances. Each jurisdiction adopting the proposed amendments contained in this document should make an independent, substantiating investigation of the validity of that information for their particular use. ACKNOWLEDGEMENT The ICC Los Angeles Basin Chapter would like to express its gratitude and appreciation to all the participating committee members and correspondents that spent countless hours over the past several months assisting in the review, discussion, evaluation and drafting of the proposed recommended technical amendments to the 2013 Edition of the California Building Code, California Residential Code and California Green Building Standards Code. Special thanks go out to the following individuals without whose support and effort the recommendations presented herein would not be possible. Allen Perry, City of Los Angeles Building and Safety Department Amir Hamidzadeh, City of Agoura Hills Building and Safety Division Bill Stutsman, City of Los Angeles Building and Safety Department Carl Sramek, SEAOSC Code Committee Charles Russell, VCA Code Group Clint Lee, County of Los Angeles Building and Safety Division Craig Johnson, City of Culver City Building and Safety Division 2013 LARUCP Recommended Technical Amendments Page 3 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM Dennis Richardson, American Wood Council Erik Keshishian, City of Beverly Hills Building and Safety Bureau Fady Mattar, JAS Pacific, Inc. Fouad Barakat, County of Los Angeles Building and Safety Division Fred Turner, Seismic Safety Commission Gustav Bohm, City of Santa Monica Building and Safety Division Hassan Alameddine, County of Los Angeles Building and Safety Division Henry Huang, Bureau Veritas James Gorbin, City of Torrance Building and Safety Division James Lai, SEAOSC Seismology Committee Jameson Lee, City of Los Angeles Building and Safety Department Jesse De Anda, City of Beverly Hills Jonathan Lam, County of Los Angeles Building and Safety Division Juan Madrigal, County of Los Angeles Building and Safety Division Karyn Beebe, APA Kermit Robinson, ICC Larry Brugger, JAS Pacific Larry Francois, SoCal Rooms Larry Lee, City of Los Angeles Building and Safety Department Matthew Gatewood, City of Los Angeles Fire Department Mazen Dudar, County of Los Angeles Building and Safety Division Mehrasa Khanpour, City of Santa Monica Building and Safety Division Miroslav Lhotsky, City of Glendale Building and Safety Division Nick Horeczko, ICC Orville Sabado, City of Santa Monica Building and Safety Division Osama Younan, City of Los Angeles Building and Safety Department Paul Armstrong, CSG Consultants Philip Yin, City of Long Beach Building and Safety Bureau Richard Hess, Hess Engineering Rick Skosnik, City of Beverly Hills Building and Safety Bureau Ritchie Kato, CSG Consultants Ron Takiguchi, City of Santa Monica Building and Safety Division Sarkis Hairapetian, City of Glendale Building and Safety Division Sarkis Nazerian, City of Pasadena Building and Safety Sharon Goei, City of Walnut Creek Steve Cloke, SEAOSC Seismology Committee Steve Ikkanda, ICC Steve Lam, County of Los Angeles Building and Safety Division Suen Lieu, City of Los Angeles Building and Safety Department Tim Kaucher, Simpson Strong -Tie Co. Tim McCormick, VCA Code Group Timothy Koutsouros, City of Santa Monica Building and Safety Division Tom Van Dorpe, SEAOSC Light -Frame Systems Committee Tracy Tam, City of Burbank Building and Safety Truong Huynh, City of Long Beach Building and Safety Bureau Victor Cuevas, City of Los Angeles Building and Safety Department 2013 LARUCP Recommended Technical Amendments Page 4 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM EXPRESS TERM LANGUAGE LOCAL GOVERNMENT AMENDMENTS UNDER THE BUILDING STANDARDS LAW: Pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code, the Building Standards Law takes a straightforward approach to amendments by local governments. Local amendments are permitted under the following conditions: • The governing body of the local government must make express findings that amendments to the building standard contained in California Codes of Regulation Title 24 are necessary because of local climatic, geological, topographical or environmental conditions. • The local government amendments must provide a more restrictive building standard than that contained in California Codes of Regulation Title 24 • The amendments are not effective until copies of both the express findings and the amendments, with the amendments expressly marked and identified as to the applicable findings, have been filed with the California Building Standards Commission. LEGEND FOR PROPOSING AMENDMENTS TO PROPOSED BUILDING STANDARDS: 1. Existing California amendments or code language being modified: All such language shown in italics, modified language is underlined or shown in fet 2. Model code language with new California amendments: Model code language shown in Arial 10 fonts; California amendments to the model code texts shown underlined and in italics. 3. Proposed amended or adopted text: All language shown in underline. 4. Repealed text: All language shown in stF at 2013 LARUCP Recommended Technical Amendments Page 5 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM TABLE OF CONTENT 8 TITLE /DESCRIPTION PAGE Preface 2 Discussion 2 Statement on Use of Document 3 Acknowledgement 3 Express Term Language 5 Table of Content 6 PART 8 Summary of Recommended LARUCP Amendments to the 2013 CBC 9 2013 LARUCP 15 -01 Amend CBC Section 1507.3.1 Deck Requirements 11 2013 LARUCP 16 -01 Add CBC Section 1613.6 Building Separation 12 2013 LARUCP 16 -02 Add CBC Section 1613.7 Values for Vertical Combinations 13 2013 LARUCP 16 -03 Add CBC Section 1613.8 Subdiaphragm 14 2013 LARUCP 16 -04 Add CBC Section 1613.9 Hillside Building 15 2013 LARUCP 16 -05 Add CBC Section 1613.10 Suspended Ceiling 22 2013 LARUCP 17 -01 Amend CBC Section 1704.5 Structural Observation General 24 2013 LARUCP 17 -02 Amend CBC Section 1704.5.1 Structural Observation Seismic 26 2013 LARUCP 17 -03 Amend CBC Section 1705.3 Special Inspection — Concrete Construction 27 2013 LARUCP 17 -04 Amend CBC Table 1705.3 Special Inspection — Anchors in Concrete 28 2013 LARUCP 17 -05 Amend CBC Section 1705.11 Seismic Resistance Inspection 29 2013 LARUCP 17 -06 Amend CBC Section 1711.1 Joist Hangers 31 2013 LARUCP 18 -01 Amend CBC Section 1807.1.4 Permanent Wood Foundation Systems 33 2013 LARUCP 18 -02 Amend CBC Section 1807.1.6 Prescriptive Design of Foundation Walls 34 2013 LARUCP 18 -03 Amend CBC Section 1809.3 Stepped Footings 35 2013 LARUCP 18 -04 Amend CBC Table 1809.7 Prescriptive Footings 36 2013 LARUCP 18 -05 Amend CBC Section 1809.12 Timber Footings 37 2013 LARUCP 18 -06 Amend CBC Section 1810.3.2.4 Timber 38 2013 LARUCP 19 -01 Amend CBC Sections 1905.1.3 Wall Pier 39 2013 LARUCP 19 -02 Amend CBC Section 1905.1.8 Minimum Reinforcement 41 2013 LARUCP 19 -03 Amend CBC Section 1905.1 Reinforcement 43 2013 LARUCP 23 -01 Amend CBC Section 2304.9.1 Fastener Requirements 45 2013 LARUCP 23 -02 Amend CBC Section 2304.11.7 Wood Retaining Walls 46 2013 LARUCP 23 -03 Amend CBC Section 2305.4 Quality of Nails 47 2013 LARUCP 23 -04 Add CBC Section 2305.5 Hold -Down Connectors 48 2013 LARUCP 23 -05 Amend CBC Section 2306.2 Wood -Frame Diaphragms 49 2013 LARUCP 23 -06 Amend CBC Section 2306.3 Wood -Frame Shear Walls 51 2013 LARUCP 23 -07 Amend CBC Section 2308.3.4 Brace Wall Line Support 53 2013 LARUCP 23 -08 Amend CBC Section 2308.9.3 Alternate Bracing 54 2013 LARUCP 23 -09 Amend CBC Table 2308.12.4 Braced Wall Sheathing 58 2013 LARUCP 23 -10 Amend CBC Section 2308.12.5 Attachment of Sheathing 59 PART II 60 Summary of Recommended LARUCP Amendments to the 2010 CRC 61 2013 LARUCP R3 -01 Amend CRC Section R301.1.3.2 Woodframe Structures 62 2013 LARUCP R3 -02 Amend CRC Section R301.1.4 Slopes Steeper Than 33% 63 2013 LARUCP R3 -03 Amend CRC Section R301.2.2.1 Seismic Design Category 64 2013 LARUCP R3 -04 Amend CRC Section R301.2.2.2.5 Building Irregularities 66 2013 LARUCP R3 -05 Add CRC Section R301.2.2.3.8 Mechanical Equipment Anchorage 68 2013 LARUCP R4 -01 Amend CRC Section R401.1 Foundation Application 69 2013 LARUCP R4 -02 Amend CRC Section R403.1 General Footings 71 2013 LARUCP Recommended Technical Amendments Page 6 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R4 -03 Amend CRC Section R404.2 Wood Foundation Walls 73 2013 LARUCP R5 -01 Amend CRC Section R501.1 Application 74 2013 LARUCP R5 -02 Amend CRC Section R503.2.4 Openings In Horizontal Diaphragms 75 2013 LARUCP R6 -01 Amend CRC Table R602.3(1) Fastener Schedule 77 2013 LARUCP R6 -02 Amend CRC Table R602.3(2) Alternate Attachment 79 2013 LARUCP R6 -03 Amend CRC Table R602.10.3(3) Bracing Requirement 80 2013 LARUCP R6 -04 Amend CRC Table R602.10.4 Intermittent Bracing Method 83 2013 LARUCP R6 -05 Amend CRC Figure R602.10.6.1 Alternate Braced Wall Panel 86 2013 LARUCP R6 -06 Amend CRC Figure R602.10.6.2 Portal Frame 88 2013 LARUCP R6 -07 Amend CRC Table R602.10.5 Braced Wall Panels 90 2013 LARUCP R6 -08 Amend CRC Section R602.10.2.3 Minimum Braced Wall Panels 92 2013 LARUCP R6 -09 Amend CRC Figure R602.10.6.4 Method CS -PF 93 2013 LARUCP R6 -10 Delete CRC Section R602.10.9.1 Braced Wall Panel 95 2013 LARUCP R6 -11 Amend CRC Section R606.2.4 Parapet Walls 96 2013 LARUCP R6 -12 Amend CRC Section R606.12.2.2.3 Reinforcement for Masonry 97 2013 LARUCP R6 -13 Amend CRC Section R602.3.2 Single Top Plate 98 2013 LARUCP R8 -01 Add CRC Section R803.2.4 Openings in Horizontal Diaphragms 99 2013 LARUCP R10 -01 Amend CRC Section R1001.3.1 Vertical Reinforcing 100 PART III 101 Summary of Recommended LARUCP Amendments to the 2013 CGBSC 102 2013 LARUCP G1 -01 Add CGBSC Section 101.12 Fee for Mandatory Measures 103 2013 LARUCP G1 -02 Add CGBSC Section 101.12.1 Fee for TIER Measures 104 2013 LARUCP G2 -01 Amend CGBSC Section 202 Sustainability Definition 105 2013 LARUCP G3 -01 Amend CGBSC Section 301.1 Scope 106 2013 LARUCP G3 -02 Amend CGBSC Section 301.1.1 Additions & Alteration 107 2013 LARUCP G4 -01 Amend CGBSC Section 5.408.3 Excavated Soil and Land Clearing Debris 109 2013 LARUCP G4 -01 Add CGBSC Section 601.1 Reference Organization and Standards Table 110 PART IV 111 Summary of Recommended LARUCP Amendments to the 2013 CGBSC 112 2013 LARUCP GA4 -01 Amend CGBSC Section A4.105.2 Reuse of Materials 113 2013 LARUCP GA4 -02 Amend CGBSC Section A4106.5 Cool Roof for Reduction of Heat Island 114 Effect 2013 LARUCP GA4 -03 Amend CGBSC Section A4.303.4 Nonwater Supplied Urinals and 116 Waterless Toilets 2013 LARUCP GA4 -04 Amend CGBSC Section A4.404.3 Building Systems 117 2013 LARUCP GA4 -05 Amend CGBSC Section A4.405.1 Prefinished Building Materials 118 2013 LARUCP GA4 -06 Amend CGBSC Section A4.405.4 Use of Building Materials From 119 Rapidly Renewable Sources 2013 LARUCP GA4 -07 Amend CGBSC Section A4.407.1 Drainage Around Foundation 120 2013 LARUCP GA4 -08 Amend CGBSC Section A4.408.1 Enhanced Construction Waste 121 Reduction 2013 LARUCP GA5 -01 Amend CGBSC Section A5.106.4.1 Short Term Bicycle Parking 122 2013 LARUCP GA5 -02 Amend CGBSC Section A5.106.4.1 Short Term Bicycle Parking 123 2013 LARUCP GA5 -03 Amend CGBSC Section A5.106.6.1 Reducing Parking Capacity 124 2013 LARUCP GA5 -04 Amend CGBSC Section A5.106.11.2 Cool Roof 125 2013 LARUCP GA5 -05 Amend CGBSC Section A5.406.1 Choice of Materials 126 2013 LARUCP Recommended Technical Amendments Page 7 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM PART I RECOMMENDED LARUCP AMENDMENTS TO THE 2013 EDITION OF THE CALIFORNIA BUILDING CODE 2013 LARUCP Recommended Technical Amendments Page 8 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM SUMMARY OF RECOMMENDED LARUCP AMENDMENTS TO THE 2013 CBC (N) 2013 LARUCP NO. (E) 2010 LARUCP NO. TITLE /DESCRIPTION STATUS DATE 15 -01 Amend CBC Section 1507.3.1 Deck Requirements N 5/7/13 16 -01 Amend CBC Section 1613.6.1 Assumption of Flexible Diaphragm D 16 -01 16 -02 Add CBC Section 1613.6 Building Separation M 10/16/12 16 -03 Add CBC Section 1613.8 BRBF Period Parameter 16 -02 16 -04 Add CBC Section 1613.7 Values for Vertical Combinations R 10/16/12 16 -05 Add CBC Section 1613.10 Stability Coefficient D 16 -03 16 -06 Add CBC Section 1613.8 Subdiaphragm R 10/16/12 16 -04 16 -07 Add CBC Section 1613.9 Hillside Building M 11/6/12 16 -05 16 -08 Add CBC Section 1613.10 Suspended Ceiling M 10/16/12 17 -02 Amend CBC Section 1704.4 SI for Concrete Construction D 17 -03 Amend CBC Section 1704.8 Driven Deep Foundations D 17 -01 17 -05 Amend CBC Section 1704.5 Structural Observations General M 11/27/12 17 -02 17 -06 Amend CBC Section 1704.5.1 Structural Observations Seismic M 11/27/13 17 -03 17 -01 Amend CBC Section 1705.3 Special Inspection for Concrete Construction M 11/27/12 17 -04 Amend CBC Table 1705.3 Special Inspection for Concrete Construction N 6/13/13 17 -05 17 -04 Amend CBC Section 1705.11 Seismic Resistance Inspection M 4/10/13 17 -06 Amend CBC Section 1711.1 Joist Hangers N 6/13/13 18 -01 18 -01 Amend CBC Section 1807.1.4 Permanent Wood Foundation System R 11/6/12 18 -02 18 -02 Amend CBC Section 1807.1.6 Prescriptive Design of Foundation Walls R 11/6/12 18 -03 18 -03 Amend CBC Section 1809.3 Stepped Footings M 11/6/12 18 -04 18 -04 Amend CBC Section 1809.7 and Table 1809.7 Prescriptive Footings R 11/6/12 18 -05 18 -05 Amend CBC Section 1809.12 Timber Footings R 11/6/12 18 -06 18 -06 Amend CBC Section 1810.3.2.4 Timber R 11/6/12 19 -02 Amend CBC Section 1908.1.2 Intermediate Structural Wall D 19 -01 19 -03 Amend CBC Section 1905.1.3 Wall Pier M 11/27/12 19 -02 19 -04 Amend CBC Section 1905.1.8 Minimum Reinforcement M 11/27/12 19 -03 19 -01 Add CBC Sections 1905.1.11 thru 13 Reinforcement M 11/27/12 19 -05 Amend CBC Section 1909.4 Structural Plain Concrete Design D 22 -01 Add CBC Section 2204. 1.1 Consumables for Welding D 22 -02 Add CBC Section 2205.4 SCBF Member Type D 23 -01 23 -10 Amend CBC Section 2304.9.1 Fastener Requirement R 10/16/12 23 -02 23 -01 Amend CBC Section 2304.11.7 Wood Retaining Walls R 10/16/12 23 -03 23 -02 Add CBC Section 2305.4 Quality of Nails R 10/16/12 23 -04 23 -03 Add CBC Section 2305.5 Hold -down Connectors R 10/16/12 23 -05 23 -04 Amend CBC Section 2306.2 Wood Diaphragm M 10/16/12 23 -06 23 -05 Amend CBC Section 2306.3 Wood Shear Walls M 12/18/12 23 -06 Amend CBC Section 2306.7 Other Shear Walls D 23 -07 23 -07 Amend CBC Section 2308.3.4 Brace Wall Line Support M 10/16/12 2013 LARUCP Recommended Technical Amendments Page 9 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FOOTNOTE: 1. R = Retain, M = Modify, D = Delete (the existing 2010 LARUCP code amendment). N = New. 2013 LARUCP Recommended Technical Amendments Page 10 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code 23 -08 Amend CBC Section 2308.12.2 Concrete or Masonry D 23 -08 Amend CBC Sections 2308.9.3.1 and 2308.9.3.2 and Figure 2308.9.3.2 Alternative Bracing N 6/13/13 23 -09 23 -09 Amend CBC Table 2308.12.4 Braced Wall Sheathing M 12/18/12 23 -10 23 -11 Amend CBC Section 2308.12.5 Attachment of Sheathing R 10/16/12 FOOTNOTE: 1. R = Retain, M = Modify, D = Delete (the existing 2010 LARUCP code amendment). N = New. 2013 LARUCP Recommended Technical Amendments Page 10 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 15 -01. Section 1507.3.1 of the 2013 Edition of the California Building Code is amended to read as follows: 1507.3.1 Deck requirements. Concrete and clay tile shall be installed only over solid Sheathing er spaced structural sheathing boards. RATIONALE Section 1507.3.1 is amended to require concrete and clay tiles to be installed only over solid structural sheathing boards. The change is necessary because there were numerous observations of tile roofs pulling away from wood framed buildings following the 1994 Northridge Earthquake. The SEAOSC /LA City Post Northridge Earthquake committee findings indicated significant problems with tile roofs was due to inadequate design and /or construction. Therefore, the amendment is needed to minimize such occurrences in the event of future significant earthquakes. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake, the 1987 Whittier Narrows Earthquake, the 1971 San Fernando Earthquake and the 1933 Long Beach Earthquake. This amendment will reduce the failure of concrete and clay tile roofs during a significant earthquake and is in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 11 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 16 -01. Section 1613.6 is added to Chapter 16 of the 2013 Edition of the California Building Code to read as follows: 1613.6 ASCE 7, 12.12.3 Modify ASCE 7 Equation 12.12 -1 of Section 12.12.3 to read as follows: 8M = C dgmax (12.12 -1) RATIONALE: The inclusion of the importance factor in this equation has the unintended consequence of reducing the minimum seismic separation distance for important facilities such as hospitals, schools, police and fire stations from adjoining structures. The proposal to omit the importance factor from Equation 12.12 -1 will ensure that a safe seismic separation distance is provided. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake, the 1987 Whittier Narrows Earthquake, the 1971 San Fernando Earthquake and the 1933 Long Beach Earthquake. The proposed modification to omit the importance factor in the equation ensures that a safe seismic separation distance is maintained for important facilities from adjoining structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 12 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 16 -02. Section 1613.7 is added to Chapter 16 of the 2013 Edition of the California Building Code to read as follows: 1613.7 ASCE 7, 12.2.3.1, Exception 3. Modify ASCE 7 Section 12.2.3.1 Exception 3 to read as follows: 3. Detached one- and two - family dwellings up to two stories in height of light frame construction. RATIONALE: Observed damages to one and two family dwellings of light frame construction after the Northridge Earthquake may have been partially attributed to vertical irregularities common to this type of occupancy and construction. In an effort to improve quality of construction and incorporate lesson learned from studies after the Northridge Earthquake, the proposed modification to ASCE 7 -10 Section 12.2.3.1 Exception 3 by limiting the number of stories and height of the structure to two stories will significantly minimize the impact of vertical irregularities and concentration of inelastic behavior from mixed structural systems. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to limit mixed structural system to two stories is intended to improve quality of construction by reducing potential damages that may result from vertical irregularities of the structural system in buildings subject to high seismic load and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 13 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 16 -03. Section 1613.8 is added to Chapter 16 of the 2013 Edition of the California Building Code to read as follows: 1613.8 ASCE 7, Section 12.11.2.2.3. Modify ASCE 7, Section 12.11.2.2.3 to read as follows: 12.11.2.2.3 Wood Diaphragms. In wood diaphragms, the continuous ties shall be in addition to the diaphragm sheathing. Anchorage shall not be accomplished by use of toe nails or nails subject to withdrawal nor shall wood ledgers or framing be used in cross -grain bending or cross -grain tension. The diaphragm sheathing shall not be considered effective as providing ties or struts required by this section. For structures assigned to Seismic Design Category D, E or F, wood diaphragms supporting concrete or masonry walls shall comply with the following: 1. The spacing of continuous ties shall not exceed 40 feet. Added chords of diaphragms may be used to form subdiaphragms to transmit the anchorage forces to the main continuous crossties. 2. The maximum diaphragm shear used to determine the depth of the subdiaphragm shall not exceed 75% of the maximum diaohraam shear. RATIONALE: A joint Structural Engineers Association of Southern California (SEAOSC), Los Angeles County and Los Angeles City Task Force investigated the performance of concrete and masonry construction with flexible wood diaphragm failures after the Northridge earthquake. It was concluded at that time that continuous ties are needed at specified spacing to control cross grain tension in the interior of the diaphragm. Additionally, there was a need to limit subdiaphragm allowable shear loads to control combined orthogonal stresses within the diaphragm. Recognizing the importance and need to continue the recommendation made by the task force while taking into consideration the improve performances and standards for diaphragm construction today, this proposal increases the continuous tie spacing limit to 40 ft in lieu of 25 ft and to use 75% of the allowable code diaphragm shear to determine the depth of the sub - diaphragm in lieu of the 300 plf and is deemed appropriate and acceptable. Due to the frequency of this type of failure during the past significant earthquakes, various jurisdictions within the Los Angeles region have taken this additional step to prevent roof or floor diaphragms from pulling away from concrete or masonry walls. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to require special anchorage of the diaphragm to the wall and limit the allowable shear will address special needs for concrete and masonry construction with flexible wood diaphragm and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 14 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 16 -04. Section 1613.9 is added to Chapter 16 of the 2013 Edition of the California Building Code to read as follows: 1613.9 Seismic Design Provisions for Hillside Buildings. 1613.9.1 Purpose. The purpose of this section is to establish minimum regulations for the design and construction of new buildings and additions to existing buildings when constructing such buildings on or into slopes steeper than one unit vertical in three units horizontal (33.3 %). These regulations establish minimum standards for seismic force resistance to reduce the risk of injury or loss of life in the event of earthquakes. 1613.9.2 Scope. The provisions of this section shall apply to the design of the lateral- force - resisting system for hillside buildings at and below the base level diaphragm. The design of the lateral- force- resisting system above the base level diaphragm shall be in accordance with the provisions for seismic and wind design as required elsewhere in this division. Exception: Non - habitable accessory buildings and decks not supporting or supported from the main building are exempt from these regulations. 1613.9.3 Definitions. For the purposes of this section certain terms are defined as follows: BASE LEVEL DIAPHRAGM is the floor at, or closest to, the top of the highest level of the frn jnriatinn DIAPHRAGM ANCHORS are assemblies that connect a diaphragm to the adjacent foundation at the uphill diaphragm edge. DOWNHILL DIRECTION is the descending direction of the slope approximately perpendicular to the slope contours. FOUNDATION is concrete or masonry which supports a building, including footings, stem walls, retaining walls, and grade beams. FOUNDATION EXTENDING IN THE DOWNHILL DIRECTION is a foundation running downhill and approximately perpendicular to the uphill foundation. HILLSIDE BUILDING is any building or portion thereof constructed on or into a slope steeper than one unit vertical in three units horizontal (33.3 %). If only a portion of the building is supported on or into the slope, these regulations apply to the entire building. PRIMARY ANCHORS are diaphragm anchors designed for and providing a direct connection as described in Sections 1613.9.5 and 1613.9.7.3 between the diaphragm and the uphill foundation. SECONDARY ANCHORS are diaphragm anchors designed for and providing a redundant diaphragm to foundation connection, as described in Sections 1613.9.6 and 1613.9.7.4. UPHILL DIAPHRAGM EDGE is the edge of the diaphragm adjacent and closest to the highest ground level at the perimeter of the diaphragm. UPHILL FOUNDATION is the foundation parallel and closest to the uphill diaphragm edge. 1613.9.4 Analysis and Design. 1613.9.4.1 General. Every hillside building within the scope of this section shall be analyzed, designed, and constructed in accordance with the provisions of this division. When the code- 2013 LARUCP Recommended Technical Amendments Page 15 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM prescribed wind design produces greater effects, the wind design shall govern, but detailing requirements and limitations prescribed in this and referenced sections shall be followed. 1613.9.4.2 Base Level Diaphragm- Downhill Direction. The following provisions shall apply to the seismic analysis and design of the connections for the base level diaphragm in the downhill direction. 1613.9.4.2.1 Base for Lateral Force Design Defined. For seismic forces acting in the downhill direction, the base of the building shall be the floor at or closest to the top of the highest level of the foundation. 1613.9.4.2.2 Base Shear. In developing the base shear for seismic design, the response modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems. The total base shear shall include the forces tributary to the base level diaphragm including forces from the base level diaphragm. 1613.9.5 Base Shear Resistance - Primary Anchors. 1613.9.5.1 General. The base shear in the downhill direction shall be resisted throu anchors from diaphragm struts provided in the base level diaphragm to the foundation. 1613.9.5.2 Location of Primary Anchors. A primary anchor and diaphragm strut shall be provided in line with each foundation extending in the downhill direction. Primary anchors and diaphragm struts shall also be provided where interior vertical lateral- force - resisting elements occur above and in contact with the base level diaphragm. The spacing of primary anchors and diaphraam struts or collectors shall in no case exceed 30 feet (9144 mm). 1613.9.5.3 Design of Primary Anchors and Diaphragm Struts. Primary anchors and diaphraam struts shall be desianed in accordance with the reauirements of Section 1613.9.8. 1613.9.5.4 Limitations. The following lateral- force - resisting elements shall not be designed to resist seismic forces below the base level diaphragm in the downhill direction: 1. Wood structural panel wall sheathing, 2. Cement plaster and lath, 3. Gypsum wallboard, and 4. Tension only braced frames. Braced frames designed in accordance with the requirements of Section 2205.2.2 may be used to transfer forces from the primary anchors and diaphragm struts to the foundation provided lateral forces do not induce flexural stresses in any member of the frame or in the diaphragm struts. Deflections of frames shall account for the variation in slope of diagonal members when the frame is not rectangular. 1613.9.6. Base Shear Resistance - Secondary Anchors. 1613.9.6.1 General. In addition to the primary anchors required by Section 1613.9.5, the base shear in the downhill direction shall be resisted through secondary anchors in the uphill foundation connected to diaphragm struts in the base level diaphragm. Exception: Secondary anchors are not required where foundations extending in the downhill direction spaced at not more than 30 feet (9144 mm) on center extend up to and are directly connected to the base level diaphragm for at least 70% of the diaphragm depth. 1613.9.6.2 Secondary Anchor Capacity and Spacing. Secondary anchors at the base level diaphragm shall be designed for a minimum force equal to the base shear, including forces 2013 LARUCP Recommended Technical Amendments Page 16 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM tributary to the base level diaphragm, but not less than 600 pounds per lineal foot (8.76 kN /m). The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of four feet (1219 mm) on center. 1613.9.6.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with Section 1613.9.8. 1613.9.7 Diaphragms Below the Base Level- Downhill Direction. The following provisions shall apply to the lateral analysis and design of the connections for all diaphragms below the base level diaphragm in the downhill direction. 1613.9.7.1 Diaphragm Defined. Every floor level below the base level diaphragm shall be designed as a diaphragm. 1613.9.7.2 Design Force. Each diaphragm below the base level diaphragm shall be designed for all tributary loads at that level using a minimum seismic force factor not less than the base shear coefficient. 1613.9.7.3 Design Force Resistance - Primary Anchors. The design force described in Section 1613.9.7.2 shall be resisted through primary anchors from diaphragm struts provided in each diaohraam to the foundation. Primary anchors shall be provided and desianed in accordance with the reauirements and limitations of Section 1613.9.5. 1613.9.7.4 Design Force Resistance - Secondary Anchors. 1613.9.7.4.1 General. In addition to the primary anchors required in Section 1613.9.7.3, the design force in the downhill direction shall be resisted through secondary anchors in the uphill foundation connected to diaphragm struts in each diaphragm below the base level. Exception: Secondary anchors are not required where foundations extending in the downhill direction, spaced at not more than 30 feet (9144 mm) on center, extend up to and are directly connected to each diaphragm below the base level for at least 70% of the diaphragm depth. 1613.9.7.4.2 Secondary Anchor Capacity. Secondary anchors at each diaphragm below the base level diaphragm shall be designed for a minimum force equal to the design force but not less than 300 pounds per lineal foot (4.38 kN /m). The secondary anchors shall be uniformly distributed along the uphill diaphragm edge and shall be spaced a maximum of four feet (1219 mm) on center. 1613.9.7.4.3 Design. Secondary anchors and diaphragm struts shall be designed in accordance with Section 1613.9.8. 1613.9.8 Primary and Secondary Anchorage and Diaphragm Strut Design. Primary and secondary anchors and diaphragm struts shall be designed in accordance with the following provisions: 1. Fasteners. All bolted fasteners used to develop connections to wood members shall be provided with square plate washers at all bolt heads and nuts. Washers shall be minimum 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Nuts shall be tightened to finger tight plus one half (1/2) wrench turn prior to covering the framing. 2. Fastening. The diaphragm to foundation anchorage shall not be accomplished by the use of toenailing, nails subject to withdrawal, or wood in cross -grain bending or cross -grain tension. 2013 LARUCP Recommended Technical Amendments Page 17 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 3. Size of Wood Members. Wood diaphragm struts collectors, and other wood members connected to primary anchors shall not be less than three -inch (76 mm) nominal width. The effects of eccentricity on wood members shall be evaluated as required per Item 9. 4. Design. Primary and secondary anchorage, including diaphragm struts, splices, and collectors shall be designed for 125% of the tributary force. 5. Allowable Stress Increase. The ^tea allowable stress increase permitted under Section 1605.3.2 shall not be taken when the working (allowable) stress design method is used. 6. Steel Element of Structural Wall Anchorage System. The strength design forces for steel elements of the structural wall anchorage system, with the exception of anchor bolts and reinforcing steel, shall be increased by 1.4 times the forces otherwise required. 7. Primary Anchors. The load path for primary anchors and diaphragm struts shall be fully developed into the diaphragm and into the foundation. The foundation must be shown to be adequate to resist the concentrated loads from the primary anchors. 8. Secondary Anchors. The load path for secondary anchors and diaphragm struts shall be fully developed in the diaphragm but need not be developed beyond the connection to the foundation. 9. Symmetry. All lateral force foundation anchorage and diaphragm strut connections shall be symmetrical. Eccentric connections may be permitted when demonstrated by calculation or tests that all components of force have been provided for in the structural analysis or tests. 10. Wood Ledgers. Wood ledgers shall not be used to resist cross -grain bending or cross -grain tension. 1613.9.9 Lateral- Force- Resisting Elements Normal to the Downhill Direction. 1613.9.9.1 General. In the direction normal to the downhill direction, lateral- force - resisting elements shall be designed in accordance with the requirements of this section. 1613.9.9.2 Base Shear. In developing the base shear for seismic design, the response modification coefficient (R) shall not exceed 5 for bearing wall and building frame systems. 1613.9.9.3 Vertical Distribution of Seismic Forces. For seismic forces acting normal to the downhill direction the distribution of seismic forces over the height of the building using Section 12.8.3 of ASCE 7 shall be determined using the height measured from the top of the lowest level of the building foundation. 1613.9.9.4 Drift Limitations. The story drift below the base level diaphragm shall not exceed 0.007 times the story height at strength design force level. The total drift from the base level diaphragm to the top of the foundation shall not exceed 3/4 inch (19 mm). Where the story height or the height from the base level diaphragm to the top of the foundation varies because of a stepped footing or story offset, the height shall be measured from the average height of the top of the foundation. The story drift shall not be reduced by the effect of horizontal diaphragm stiffness. 1613.9.9.5 Distribution of Lateral Forces. 1613.9.9.5.1 General. The design lateral force shall be distributed to lateral- force - resisting elements of varying heights in accordance with the stiffness of each individual element. 2013 LARUCP Recommended Technical Amendments Page 18 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 1613.9.9.5.2 Wood Structural Panel Sheathed Walls. The stiffness of a stepped wood structural panel shear wall may be determined by dividing the wall into adjacent rectangular elements, subject to the same top of wall deflection. Deflections of shear walls may be estimated by AF &PA SDPWS Section 4.3.2. Sheathing and fastening requirements for the stiffest section shall be used for the entire wall. Each section of wall shall be anchored for shear and uplift at each step. The minimum horizontal length of a step shall be eight feet (2438 mm) and the maximum vertical height of a step shall be two feet, eight inches (813 mm. 1613.9.9.5.3 Reinforced Concrete or Masonry Shear Walls. Reinforced concrete or masonry shear walls shall have forces distributed in proportion to the rigidity of each section of the wall. 1613.9.9.6 Limitations. The following lateral force - resisting- elements shall not be designed to resist lateral forces below the base level diaphragm in the direction normal to the downhill direction: 1. Cement plaster and lath, 2. Gypsum wallboard, and 3. Tension -only braced frames. Braced frames designed in accordance with the requirements of Section 2205.2.2 of this Code may be designed as lateral- force - resisting elements in the direction normal to the downhill direction, provided lateral forces do not induce flexural stresses in any member of the frame. Deflections of frames shall account for the variation in slope of diagonal members when the frame is not rectanaular. 1613.9.10 Specific Design Provisions. 1613.9.10.1 Footings and Grade Beams. All footings and grade beams shall comply with the following: 1. Grade beams shall extend at least 12 inches (305 mm) below the lowest adjacent grade and provide a minimum 24 -inch (610 mm) distance horizontally from the bottom outside face of the grade beam to the face of the descending slope. 2. Continuous footings shall be reinforced with at least two No. 4 reinforcing bars at the top and two No. 4 reinforcing bars at the bottom. 3. All main footing and grade beam reinforcement steel shall be bent into the intersecting footing and fully developed around each corner and intersection. 4. All concrete stem walls shall extend from the foundation and reinforced as required for concrete or masonry walls. 1613.9.10.2 Protection Against Decay and Termites. All wood to earth separation shall comply with the following: 1. Where a footing or grade beam extends across a descending slope, the stem wall, grade beam, or footing shall extend up to a minimum 18 inches (457 mm) above the highest adjacent grade. Exception: At paved garage and doorway entrances to the building, the stem wall need only extend to the finished concrete slab, provided the wood framing is protected with a moisture proof barrier. 2013 LARUCP Recommended Technical Amendments Page 19 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2. Wood ledgers supporting a vertical load of more than 100 pounds per lineal foot (1.46 kN /m) and located within 48 inches (1219 mm) of adjacent grade are prohibited. Galvanized steel ledgers and anchor bolts, with or without wood nailers, or treated or decay resistant sill plates supported on a concrete or masonry seat, may be used. 1613.9.10.3 Sill Plates. All sill plates and Anchoraae shall comply with the followina: 1. All wood framed walls, including nonbearing walls, when resting on a footing, foundation, or grade beam stem wall, shall be supported on wood sill plates bearing on a level surface. 2. Power - driven fasteners shall not be used to anchor sill plates except at interior nonbearing walls not designed as shear walls. 1613.9.10.4 Column Base Plate Anchorage. The base of isolated wood posts (not framed into a stud wall) supporting a vertical load of 4,000 pounds (17.8 kN) or more and the base plate for a steel column shall comply with the following: 1. When the post or column is supported on a pedestal extending above the top of a footing or grade beam, the pedestal shall be designed and reinforced as required for concrete or masonry columns. The pedestal shall be reinforced with a minimum of four No. 4 bars extending to the bottom of the footing or grade beam. The top of exterior pedestals shall be sloped for positive drainage. 2. The base plate anchor bolts or the embedded portion of the post base, and the vertical reinforcing bars for the pedestal, shall be confined with two No. 4 or three No. 3 ties within the top five inches (127 mm) of the concrete or masonry pedestal. The base plate anchor bolts shall be embedded a minimum of 20 bolt diameters into the concrete or masonry pedestal. The base plate anchor bolts and post bases shall be galvanized and each anchor bolt shall have at least two galvanized nuts above the base plate. 1613.9.10.5 Steel Beam to Column Supports. All steel beam to column supports shall be Positively braced in each direction. Steel beams shall have stiffener plates installed on each side of the beam web at the column. The stiffener plates shall be welded to each beam flange and the beam web. Each brace connection or structural member shall consist of at least two 5/8 inch (15.9 mm) diameter machine bolts. RATIONALE: Due to the difficulty of fire suppression vehicles accessing winding and narrow hillside properties and the probabilities for future earthquakes in the Los Angeles region, this technical amendment is required to address the special needs for buildings constructed on hillside locations. A joint Structural Engineers Association of Southern California (SEAOSC) and both the Los Angeles County and Los Angeles City Task Force investigated the performance of hillside building failures after the Northridge earthquake. Numerous hillside failures resulted in loss of life and millions of dollars in damage. These criteria were developed to minimize the damage to these structures and have been in use by both the City and County of Los Angeles for several years with much success. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: 2013 LARUCP Recommended Technical Amendments Page 20 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM Local Topographical and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. Additionally, the topography within the Los Angeles region includes significant hillsides with narrow and winding access that makes timely response by fire suppression vehicles challenging and difficult. The proposed modification establishes design parameters to better mitigate and limit property damage that are the results of increased seismic forces which are imparted upon hillside buildings and structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 21 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 16 -05. Section 1613.10 is added to Chapter 16 of the 2013 Edition of the California Building Code to read as follows: 1613.10 Suspended Ceilings. Minimum design and installation standards for suspended ceilings shall be determined in accordance with the requirements of Section 2506.2.1 of this Code and this section. 1613.10.1 Scope. This part contains special requirements for suspended ceilings and lighting systems. Provisions of Section 13.5.6 of ASCE 7 -10 shall apply except as modified herein. 1613.10.2 General. The suspended ceilings and lighting systems shall be limited to 6 feet (1828 mm) below the structural deck unless the lateral bracing is designed by a licensed engineer or architect. 1613.10.3 Sprinkler Heads. All sprinkler heads (drops) except fire - resistance -rated floor /ceiling or roof /ceiling assemblies, shall be designed to allow for free movement of the sprinkler pipes with oversize rings, sleeves or adaptors through the ceiling tile. Sprinkler heads and other penetrations shall have a 2 in. (50mm) oversize ring, sleeve, or adapter through the ceiling tile to allow for free movement of at least 1 in. (25mm) in all horizontal directions. Alternatively, a swing joint that can accommodate 1 in. (25 mm) of ceiling movement in all horizontal directions is permitted to be provided at the top of the sprinkler head extension. Sprinkler heads penetrating fire - resistance -rated floor /ceiling or roof /ceiling assemblies shall com with Section 714 of this Code. 1613.10.4 Special Requirements for Means of Egress. Suspended ceiling assemblies located along means of egress serving an occupant load of 30 or more shall comply with the following provisions. 1613.10.4.1 General. Ceiling suspension systems shall be connected and braced with vertical hangers attached directly to the structural deck along the means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A Occupancies. Spacing of vertical hangers shall not exceed 2 feet (610 mm) on center along the entire length of the suspended ceiling assembly located along the means of egress or at the lobby. 1613.10.4.2 Assembly Device. All lay -in panels shall be secured to the suspension ceiling assembly with two hold -down clips minimum for each tile within a 4 -foot (1219 mm) radius of the exit lights and exit signs. 1613.10.4.3 Emergency Systems. Independent supports and braces shall be provided for light fixtures required for exit illumination. Power supply for exit illumination shall comply with the requirements of Section 1006.3 of this Code. 1613.10.4.4 Supports for Appendage. Separate support from the structural deck shall be provided for all appendages such as light fixtures, air diffusers, exit signs, and similar elements. RATIONALE: The California Building Code has little to no information regarding the safe design and construction requirements for ceiling suspension systems subject to seismic loads. It is through the experience of prior earthquakes, such as the Northridge Earthquake, that this amendment is proposed so as to minimize the amount of bodily and building damage within the spaces in which this type of ceiling will be installed. This proposed amendment complements ASCE 7 -10 Chapter 13 Section 13.5.6.2.2 and the cited reference to ASTM E580. The amended requirements retained herein are a continuation of portions of an amendment adopted during the previous code adoption cycles. 2013 LARUCP Recommended Technical Amendments Page 22 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FINDINGS: Local Geological Conditions — The greater Los Angeles /Long Beach region is a densely populated area having buildings constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification requiring safe design and construction requirements for ceiling suspension systems to resist seismic loads is intended to minimize the amount of damage within a building and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 23 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 17 -01. Section 1704.5 of the 2013 Edition of the California Building Code is amended to read as follows: 1704.5 Structural Observations. Where required by the provisions of Section 1704.5.1 or 1704.5.2, the owner shall employ a FegisteFed design pmfessienal structural observer to perform structural observations as defined in Section 1702. The structural observer shall be one of the following individuals: 1. The registered design professional responsible for the structural design, or 2. A registered design professional designated by the registered design professional responsible for the structural design. Prior to the commencement of observations, the structural observer shall submit to the building official a written statement identifying the frequency and extent of structural observations. The owner or owner's representative shall coordinate and call a preconstruction meeting between the structural observer, contractors, affected subcontractors and special inspectors. The structural observer shall preside over the meeting. The purpose of the meeting shall be to identify the major structural elements and connections that affect the vertical and lateral load resisting systems of the structure and to review scheduling of the required observations. A record of the meeting shall be included in the report submitted to the buildina official. Observed deficiencies shall be reported in writing to the owner or owner's representative, special inspector, contractor and the building official. Upon the form prescribed by the building official, the structural observer shall submit to the building official a written statement at each significant construction stage stating that the site visits have been made and identifying any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. A final report by the structural observer which states that all observed deficiencies have been resolved is required before acceptance of the work by the building official. RATIONALE: The language in Section 1704.5 of the California Building Code permits the owner to employ any registered design professional to perform structural observations with minimum guideline. However, it is important to recognize that the registered design professional responsible for the structural design has thorough knowledge of the building he /she designed. By requiring the registered design professional responsible for the structural design or their designee who were involved with the design to observe the construction, the quality of the observation for major structural elements and connections that affect the vertical and lateral load resisting systems of the structure will greatly be increased. Additional requirements are provided to help clarify the role and duties of the structural observer and the method of reporting and correcting observed deficiencies to the building official. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to require the registered design professional in responsible charge for the structural design to 2013 LARUCP Recommended Technical Amendments Page 24 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM observe the construction will help ensure acceptable standards of workmanship is provided and to improve the quality of the observation and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 25 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 17 -02. Section 1704.5.1 of the 2013 Edition of the California Building Code is amended to read as follows: 1704.5.1 Structural observations for seismic resistance. Structural observations shall be provided for those structures assigned to Seismic Design Category D, E or F, where one or more of the following conditions exist: 1. The structure is classified as Risk Category III or IV in accordance with Table 1604.5. 2. The height of the structure is greater than 75 feet (22860 mm) above the base. 3. The structure is assigned to S806 Design Gategopl=E, is classified as Risk Category I or II in accordance with Table 1604.5, and isgFeater than steFies One steFies above grade plane a lateral design is required for the structure or portion thereof. Exception: One -story wood framed Group R -3 and Group U Occupancies less than 2,000 square feet in area, provided the adjacent grade is not steeper than 1 unit vertical in 10 units horizontal (10% sloped), assigned to Seismic Design Category D. 4. When so designated by the registered design professional responsible for the structural design. 5. When such observation is specifically required by the building official. RATIONALE: With the higher seismic demand placed on buildings and structures in this region, the language in Section 1704.5.1 of the California Building Code would permit many low -rise buildings and structures with complex structural elements to be constructed without the benefit of a structural observation. By requiring a registered design professional to observe the construction, the quality of the observation for major structural elements and connections that affect the vertical and lateral load resisting systems of the structure will greatly be increased. An exception is provided to permit simple structures and buildings to be excluded. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to require the registered design professional in responsible charge for the structural design to observe the construction will help ensure acceptable standards of workmanship is provided and to improve the quality of the observation and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 26 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 17 -03. Section 1705.3 of the 2013 Edition of the California Building Code is amended to read as follows: 1705.3 Concrete Construction. The special inspections and verifications for concrete construction shall be as required by this section and Table 1705.3. Exceptions: Special inspection shall not be required for: 1. Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f'c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa) regardless of the compressive strength specified in the construction documents or used in the footing construction. 2. Continuous concrete footings supporting walls of buildings three stories or less in height that are fully supported on earth or rock where: 2.1. The footings support walls of light -frame construction; 2.2. The footings are designed in accordance with Table 1805.4.2; or 2.3. The structural design of the footing is based on a specified compressive strength, f'c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa), regardless of the compressive strength specified in the construction documents or used in the footing construction. 3. Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 Mpa). 54. Concrete patios, driveways and sidewalks, on grade. RATIONALE: Results from studies after the 1994 Northridge Earthquake indicated that a lot of the damage was attributed to a lack of quality control during construction resulting in poor performance of the building or structure. Therefore, the proposed amendment requires special inspection for concrete with a compressive strength greater than 2,500 pounds per square inch. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to require special inspection for concrete with a compressive strength greater than 2,500 psi to improve quality of control during construction and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 27 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 17 -04. Table 1705.3 of the 2013 Edition of the California Building Code is amended to read as follows: TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION VERIFICATION AND CONTINOUS PERIODIC REFERENCE IBC INSPECTION STANDARD REFERENCE 3. Inspection of anchors cast in concrete where allowable loads have been increased or where — X ACI 318: D.9.2 8.1.3, 21.1.-B 1908.5, - strength design is used. 4. Inspection of anchors post- _ AGI 318 1999.1 installed in hardened concrete X 21.1.8 membersb a. Adhesive anchors installed in horizontally or upwardly inclined X ACI 318:D.9.2.4 _ orientations to resist sustained tension loads. X ACI 318: D.9.2 _ b. Mechanical anchors and adhesive anchors not defined in 4.a. b. Specific requirements for special inspection shall be included in the research report for the anchor issued by an approved source in accordance with ACI 355.2 D.9.2 in ACI 318, or other qualification procedures. Where specific requirements are not provided, special inspection requirements shall be specified by the registered design professional and shall be approved by the building official prior to the commencement of the work. (Portions of table not shown remain unchanged.) RATIONALE: The requirements for the special inspection of concrete are contained in Table 1705.3, including the installation of anchors in concrete. The table currently references the 2008 Edition of the ACI 318. Appendix D9.2 has been revised in the 2011 Edition of the ACI 318 specifically to address the inspection of concrete anchors, both adhesive and mechanical anchors. Table 1705.3 is being amended to reflect the new provisions in the 2011 Edition of the ACI 318. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 28 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 17 -05. Exception 3 of Section 1705.11 of the 2013 Edition of the California Building Code is amended to read as follows: 1705.11 Special inspections for seismic resistance. Special inspections itemized in Sections 1705.11.1 through 1705.11.8, unless exempted by the exceptions of Section 1704.2, are required for the following: 1. The seismic force - resisting systems in structures assigned to Seismic Design Category C, D, E or F in accordance with Sections 1705.11.1 through 1705.11.3, as applicable. 2. Designated seismic systems in structures assigned to Seismic Design Category C, D, E or F in accordance with Section 1705.11.4. 3. Architectural, mechanical and electrical components in accordance with Sections 1705.11.5 and 1705.11.6. 4. Storage racks in structures assigned to Seismic Design Category D, E or F in accordance with Section 1705.11.7. 5. Seismic isolation systems in accordance with Section 1705.11.8. Exception: Special inspections itemized in Sections 1705.11.1 through 1705.11.8 are not required for structures designed and constructed in accordance with one of the following: 1. The structure consists of light -frame construction; the design spectral response acceleration at short periods, SpS, as determined in Section 1613.3.4, does not exceed 0.5; and the building height of the structure does not exceed 35 feet (10 668 mm) 2. The seismic force - resisting system of the structure consists of reinforced masonry or reinforced concrete; the design spectral response acceleration at short periods, SpS, as determined in Section 1613.3.4, does not exceed 0.5; and the building height of the structure does not exceed 25 feet (7620 mm) The structure is a detached one- or two - family dwelling not exceeding two stories above grade plane, is not assigned to Seismic Design Category D, E or F and does not have any of the following horizontal or vertical irregularities in accordance with Section 12.3 of ASCE 7: 3.1 Torsional or extreme torsional irregularity. 3.2 Nonparallel systems irregularity. 3.3 Stiffness -soft story or stiffness - extreme soft story irregularity. 3.4 Discontinuity in lateral strength -weak story irregularity. RATIONALE: In Southern California, very few detached one- or two - family dwellings not exceeding two stories above grade plane are built as "box- type" structures, especially those in hillside areas and near the oceanfront. Many steel moment frames or braced frames and /or cantilevered columns within buildings can still be shown as "regular" structures by calculations. With the higher seismic demand placed on buildings and structures in this region, the language in Section 1705.11 Exception 3 of the California Building Code would permit many detached one- or two - family dwellings not exceeding two stories above grade plane 2013 LARUCP Recommended Technical Amendments Page 29 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM with complex structural elements to be constructed without the benefit of special inspections. By requiring special inspections, the quality of major structural elements and connections that affect the vertical and lateral load resisting systems of the structure will greatly be increased. The exception should only be allowed for detached one- or two - family dwellings not exceeding two stories above grade plane assigned to Seismic Design category A, B and C. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to require special inspections for detached one- or two - family dwellings not exceeding two stories above grade plane assigned to Seismic Design Category D, E and F will help ensure that acceptable standards of workmanship and quality of construction are provided and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 30 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 17 -06. Section 1711.1.1, Section 1711.1.2 and Chapter 35 of the 2013 Edition of the California Building Code are amended to read as follows: 1711.1.1 General. The vertical load- bearing capacity, torsional moment capacity and deflection characteristics of joist hangers shall be determined in accordance with ASTM D 1761 and ASTM D 7147 as specified below using lumber having a specific gravity of 0.49 or greater, but not greater than 0.55, as determined in accordance with AF &PA NDS for the joist and headers. Exception: The joist length shall not be required to exceed 24 inches (610 mm). 1711.1.2 Vertical load capacity for joist hangers. The vertical load- bearing capacity for the joist hanger shall be determined by testing a minimum of three joist hanger assemblies as specified in ASTM D 1761 or ASTM D 7147. If the ultimate vertical load for any one of the tests varies more than 20 percent from the average ultimate vertical load, at least three additional tests shall be conducted. The allowable vertical load- bearing of the joist hanger shall be the lowest value determined from the following: 1. The lowest ultimate vertical load for a single hanger from any test divided by three (where three tests are conducted and each ultimate vertical load does not vary more than 20 percent from the average ultimate vertical load). 2. The average ultimate vertical load for a single hanger from all tests divided by three (where six or more tests are conducted). 3. The average from all tests of the vertical loads that produce a vertical movement of the joist with respect to the header of 1/8 inch (3.2 mm). 4. The sum of the allowable design loads for nails or other fasteners utilized to secure the joist hanger to the wood members and allowable bearing loads that contribute to the capacity of the hanger. 5. The allowable design load for the wood members forming the connection. Amend the Reference Standards in Chapter 35 for ASTM as follows: D 1761 D 1761 - 88(2000) F1 Test Method for Mechanical Fasteners in Wood 1711.1.1 1711.1.2 1711.1.3 D 7147 -05 Standard Specification for Testing and Establishing 1711.1.1 1711.1.2 Allowable Loads of Joist Hangers RATIONALE: ASTM D 1760 -06 contains exactly the same standard test methods as ASTM D 1761 -88 (2000) 61 except for joist hangers. Standard test methods for joist hangers found in former ASTM D 1761 -88 (2000)61 sections 41 to 50 were removed from ASTM D 1761 -06 due to their inclusion and update in the new standard ASTM D 7147 -05 Standard Specification for Testing and Establishing Allowable Loads of Joist Hangers. Nonetheless, both the 2009 and 2012 editions of the IBC reference ASTM D1761 -2006 for this testing. As a result, testing of joist hangers no longer has a valid reference standard. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety 2013 LARUCP Recommended Technical Amendments Page 31 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 32 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 18 -01. Section 1807.1.4 of the 2013 Edition of the California Building Code is amended to read as follows: 1807.1.4 Permanent wood foundation systems. Permanent wood foundation systems shall be designed and installed in accordance with AF &PA PWF. Lumber and plywood shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B and Section 5.2) and shall be identified in accordance with Section 2303.1.8.1. Permanent wood foundation systems shall not be used for structures assigned to Seismic Design Category D, E or F. RATIONALE: No substantiating data has been provided to show that wood foundation systems are effective in supporting buildings and structures during a seismic event while being subject to deterioration caused by the combined detrimental effects of constant moisture in the soil and wood - destroying organisms. Wood foundation systems not properly treated and protected against deterioration, have performed very poorly and have led to slope failures. Most contractors are typically accustomed to construction in dry and temperate weather in the Southern California region and are not generally familiar with the necessary precautions and treatment of wood that makes it suitable for both seismic events and wet applications. The proposed amendment takes the precautionary steps to reduce or eliminate potential problems that may result in using wood foundation systems that experience relatively rapid decay due to the fact that the region does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood - destroying organisms. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Climatic and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. In addition, the region is within a climate system capable of producing major winds, fire and rain related disasters, including but not limited to those caused by the Santa Ana winds and El Nino (or La Nina) subtropical -like weather. This region is especially susceptible to more active termite and wood attacking insects and microorganisms. The proposed modification to prohibit the use of wood foundation systems as well as limit prescriptive design provisions in an effort to mitigate potential problems or deficiencies due to the proliferation of wood - destroying organisms and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 33 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 18 -02. Section 1807.1.6 of the 2013 Edition of the California Building Code is amended to read as follows: 1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D, E or F. RATIONALE: With the higher seismic demand placed on buildings and structures in this region, it is deemed necessary to take precautionary steps to reduce or eliminate potential problems that may result by following prescriptive design provisions that does not take into consideration the surrounding environment. Plain concrete performs poorly in withstanding the cyclic forces resulting from seismic events. In addition, no substantiating data has been provided to show that under - reinforced foundation walls are effective in resisting seismic loads and may potentially lead to a higher risk of failure. It is important that the benefit and expertise of a registered design professional be obtained to properly analyze the structure and take these issues into consideration. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake. The proposed modification to prohibit prescriptive design provisions for foundation walls as plain concrete have performed poorly in withstanding the cyclic forces resulting from seismic events and to require the walls to be designed by a registered design professional to ensure that the proper analysis of the structure takes into account the surrounding condition and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 34 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 18 -03. Section 1809.3 of the 2013 Edition of the California Building Code is amended to read as follows: 1809.3 Stepped footings. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10- percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10- percent slope). For structures assigned to Seismic Design Category D, E or F, the stepping requirement shall also apply to the top surface of grade beams supporting walls. Footings shall be reinforced with four No. 4 rebar. Two bars shall be place at the top and bottom of the footings as shown in Figure 1809.3. 2 °00 N(K 2-#4 REBAR GOP & ) STEPPED FOUNDATION'S FIGURE 1809.3 STEPPED FOOTING RATIONALE: ? (rYP4 CRA 01 With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result for under reinforced footings located on sloped surfaces. Requiring minimum reinforcement for stepped footings is intended to address the problem of poor performance of plain or under - reinforced footings during a seismic event. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require minimum reinforcement in stepped footings is intended to improve performance of buildings and structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 35 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 18 -04. Section 1809.7 and Table 1809.7 of the 2013 Edition of the California Building Code are amended to read as follows: 1809.7 Prescriptive footings for light -frame construction. Where a specific design is not provided, concrete or masonry-unit footings supporting walls of light -frame construction shall be permitted to be designed in accordance with Table 1809.7. Prescriptive footings in Table 1809.7 shall not exceed one story above grade plane for structures assigned to Seismic Design Category D, E or F. TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT -FRAME CONSTRUCTION a, b, c, d, e NUMBER OF FLOORS SUPPORTED BY THE FOOTING f WIDTH OF FOOTING inches THICKNESS OF FOOTING inches 1 12 6 2 15 6 3 18 8g For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm a. Depth of footings shall be in accordance with Section 1809.4. b. The ground under the floor shall be permitted to be excavated to the elevation of the top of the footing. C. Intpronr st'-d hPRriRg walls shall be peFmitted to be suppaFted by iselated f99tiRgs. The f99tiRg width and leRgth shall ba Not Adopted. d. See Section 1908 for additional requirements for concrete footings of structures assigned to Seismic Design Category C, D, E or F. e. For thickness of foundation walls, see Section 1807.1.6. f. Footings shall be permitted to support a roof addition to the stipulated number of floors. Footings supporting roof only shall be as required for supporting one floor. RATIONALE: No substantiating data has been provided to show that under - reinforced footings are effective in resisting seismic loads and may potentially lead to a higher risk of failure. Therefore, this proposed amendment requires minimum reinforcement in continuous footings to address the problem of poor performance of plain or under - reinforced footings during a seismic event. With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result by following prescriptive design provisions for footing that does not take into consideration the surrounding environment. It was important that the benefit and expertise of a registered design professional be obtained to properly analyze the structure and take these issues into consideration. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Task Force that investigated the poor performance observed in the 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to limit the use of the prescriptive design provisions and under - reinforced or plain concrete is to ensure that the proper analysis of the structure takes into account the surrounding condition and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 36 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 18 -05. Section 1809.12 of the 2013 Edition of the California Building Code is amended to read as follows: 1809.12 Timber footings. Timber footings shall be permitted for buildings of Type V construction and as otherwise approved by the building official. Such footings shall be treated in accordance with AWPA U1 (Commodity Specification A, Use Category 4B). Treated timbers are not required where placed entirely below permanent water level, or where used as capping for wood piles that project above the water level over submerged or marsh lands. The compressive stresses perpendicular to grain in untreated timber footing supported upon treated piles shall not exceed 70 percent of the allowable stresses for the species and grade of timber as specified in the AF &PA NDS. Timber footings shall not be used in structures assigned to Seismic Design Category D, E or F. RATIONALE: No substantiating data has been provided to show that timber footings are effective in supporting buildings and structures during a seismic event, especially while being subjected to deterioration caused by the combined detrimental effects of moisture in the soil and wood - destroying organisms. Timber footings, when they are not properly treated and protected against deterioration, have performed very poorly. Most contractors are typically accustomed to construction in dry and temperate weather in the Southern California region and are not generally familiar with the necessary precautions and treatment of wood that makes it suitable for both seismic event and wet applications. The proposed amendment takes the precautionary steps to reduce or eliminate potential problems that may result by using timber footings that experience relatively rapid decay due to the face that the region does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood - destroying organisms. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Climatic and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. In addition, the region is within a climate system capable of producing major winds, fire and rain related disasters, including but not limited to those caused by the Santa Ana winds and El Nino (or La Nina) subtropical -like weather. This region is especially susceptible to more active termite and wood attacking insects and microorganisms. The proposed modification to prohibit the use of timber footings in an effort to mitigate potential problems or deficiencies due to the proliferation of wood - destroying organisms and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 37 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 18 -06. Section 1810.3.2.4 of the 2013 Edition of the California Building Code is amended to read as follows: 1810.3.2.4 Timber. Timber deep foundation elements shall be designed as piles or poles in accordance with AF &PA NDS. Round timber elements shall conform to ASTM D 25. Sawn timber elements shall conform to DOC PS -20. Timber shall not be used in structures assigned to Seismic Design Category D, E or F. RATIONALE: No substantiating data has been provided to show that timber deep foundation is effective in supporting buildings and structures during a seismic event while being subject to deterioration caused by the combined detrimental effect of constant moisture in the soil and wood - destroying organisms. Timber deep foundation, when they are not properly treated and protected against deterioration, has performed very poorly. Most contractors are typically accustomed to construction in dry and temperate weather in the Southern California region and are not generally familiar with the necessary precautions and treatment of wood that makes it suitable for both seismic event and wet applications. The proposed amendment takes the precautionary steps to reduce or eliminate potential problems that may result by using timber deep foundation that experience relatively rapid decay due to the face that the region does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood - destroying organisms. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Climatic and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. In addition, the region is within a climate system capable of producing major winds, fire and rain related disasters, including but not limited to those caused by the Santa Ana winds and El Nino (or La Nina) subtropical -like weather. This region is especially susceptible to more active termite and wood attacking insects and microorganisms. The proposed modification to prohibit the use of timber deep foundation in an effort to mitigate potential problems or deficiencies due to the proliferation of wood - destroying organisms and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 38 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 19 -01. Section 1905.1.3 of the 2013 Edition of the California Building Code is amended to read as follows: 1905.1.3 ACI 318, Section 21.4. Modify ACI 318, Section 21.4, by renumbering Section 21.4.3 to become 21.4.4 and adding new Sections 21.4.3, 21.4.5, 21.4.6 and 21.4.7 to read as follows: 21.4.3 — Connections that are designed to yield shall be capable of maintaining 80 percent of their design strength at the deformation induced by the design displacement or shall use Type 2 mechanical splices. 21.4.4 — Elements of the connection that are not designed to yield shall develop at least 1.5 Sy. 21.4.5 — Wall piers- irnrSe Design Gategvnn ry llorF- shall GGMPIY With SeGtion international C2uiLJinir rod °.ln structures assigned to Seismic Design Category D, E or F, intermediate precast wall panels and wall piers shall be designed in accordance with Section 21.9 or 21.13. 21.4.6 — Wall piers not designed as part of a moment frame in buildings assigned to Seismic Design Category C shall have transverse reinforcement designed to resist the shear forces determined from 21.3.3. Spacing of transverse reinforcement shall not exceed 8 inches (203 mm). Transverse reinforcement shall be extended beyond the pier clear height for at least 12 inches (305 mm). Exceptions: 1. Wall piers that satisfy 21.13. 2. Wall piers along a wall line within a story where other shear wall segments provide lateral support to the wall piers and such segments have a total stiffness of at least six times the sum of the stiffnesses of all the wall piers. 21.4.7 — Wall segments with a horizontal length -to- thickness ratio less than 2.5 shall be designed as columns. RATIONALE: The design provision for wall pier detailing was originally introduced by SEAOC in 1987 to legacy Uniform Building Code (UBC) and was included in the 1988 UBC through the 1997 UBC (2002 CBC). The wall pier detailing provision prescribed under Section 1905.1.4 was intended for high seismic zones equivalent to current Seismic Design Category D, E or F. Section 1905.1.3 was added as a complement of wall pier detailing in Seismic Design Category C (formerly seismic zones 2A and 2B under the legacy model code). ACI 318 Commentary R 21.1.1 emphasized "it is essential that structures assigned to higher Seismic Design Categories possess a higher degree of toughness ", and further encourages practitioners to use special structural wall system in regions of high seismic risk. ASCE 7 Table 12.2 -1 permits intermediate precast structural wall system in Seismic Design Category D, E or F. Current Section 1905.1.3 does not limit to just structures assigned to Seismic Design Category C. The required shear strength under 21.3.3, referenced in Section 21.4.6, is based on Vu under either nominal moment strength or two times the code prescribed earthquake force. The required shear strength in 21.6.5.1, referenced in Section 21.9.8.2 (IBC 1905.1.4), is based on the probable shear strength, Ve under the probable moment strength, Mpg. In addition, the spacing of required shear reinforcement is 8 inches on center under Section 21.4.6 instead of 6 inches on center with seismic hooks at both ends under Section 21.9.8.2. Requirement of wall pier under Section 21.9.8.2 would enhance better ductility. By virtue of ACI 318 Section 21.1.1.7(d), intermediate precast structural walls designed under Section 21.4, material requirements intended under provisions 21.1.4, 21.1.5, 21.1.6, and 21.1.7 would be 2013 LARUCP Recommended Technical Amendments Page 39 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM excluded for structures assigned to Seismic Design Category D, E or F. Clarification of ACI 318 Chapter 21 is needed to ensure that structural walls designed under ASCE 7 Table 12.2 -1 using the intermediate wall panel category would conform to ductility requirements comparable to special structural wall; and conformance to the long standing practice of ACI 318 to impose special requirements for high seismic design regions. Whereas new ACI 318 section 21.4.4 extends requirement for wall piers be designed in accordance with 21.9 or 21.13. This amendment gives explicit requirement under which design and detailing need to conform to special structural wall system provision in ACI -318 Section 21.9, which covers both cast -in -place as well as precast. This amendment further gives building officials the tools to enforce minimum life safety building performance under earthquake forces in Seismic Design Category D, E or F. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. Current practice in commercial buildings constructed using precast wall panel systems have large window and door openings and /or narrow wall piers. Wall panels varying up to three stories high with openings resembles wall frame which is not currently recognized under any of the defined seismic -force resisting systems other than consideration of structural wall system. Conformance to special structural wall system design and detailing of wall piers ensures minimum life safety performance in resisting earthquake forces for structures in Seismic Design Category D, E or F. Proposed modification separates wall piers designed for structures assigned to Seismic Design Category C from those assigned to Seismic Design Category D, E or F. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to wall pier detailing is intended to assure that ductility requirements for high seismic region is provided and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code and ACI 318. 2013 LARUCP Recommended Technical Amendments Page 40 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 19 -02. Section 1905.1.8 of the 2013 Edition of the California Building Code is amended to read as follows: 1905.1.8 ACI 318, Section 22.10. Delete ACI 318, Section 22.10, and replace with the following: 22.10 – Plain concrete in structures assigned to Seismic Design Category C, D, E or F. 22. 10.1 – Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows: (a) Str-UGtural plain GOnGf;9te basemen�, foundation or other walks below the base aFe peFmitted 4'R detaGhed one and Avo fam#y dweffings three stoges or less in height GGnStruGted With StUd- shall nOt eXGeed 8 feet (2438 m", the thiGkness shall not be less than 7,4 inGhes (490 mrp) and the wall shall t;qtain no more than 4 feet (4249 m" of unbalanGed fig. Wa sh t;9i Bement in aGGOrdanGe with 22.6.6.5. Concrete used for fill with a minimum cement content of two (2) sacks of Portland cement or cementious material Der cubic vard. (b) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness. (c) Plain concrete footings supporting walls are permitted provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross - sectional area of the footing. der footings that exseed 8 inGhes(203 m" in th G ne&s—aA minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections. 4_1n SeiSMiG DeeignCategoriesA, B and detached one- and two - family dwellings three stories or less in height and constructed with stud - bearing walls, are permitted to have plain concrete footings without longitudinal r° nA9rGement with at least two continuous longitudinal reinforcina bars not smaller than No. 4 are Dermitted to have a total area of less than 0.002 times the gross cross - sectional area of the footing. RATIONALE: This proposed amendment requires minimum reinforcement in continuous footings to address the problem of poor performance of plain or under - reinforced footings during a seismic event. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 2013 LARUCP Recommended Technical Amendments Page 41 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require minimum reinforcement to address the problem of poor performance of plain or under - reinforced footings during a seismic event and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 42 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 19 -03. Section 1905.1 is amended and Sections 1905.1.10 thru 1905.1.12 are added to Chapter 19 of the 2013 Edition of the California Building Code to read as follows: 1905.1 General. The text of ACI 318 shall be modified as indicated in Sections 1905.1.1 through 1 °^�01905.1.12. 1905.1.10 ACI 318, Section 21.6.4. Modify ACI 318, Section 21.6.4, by adding Section 21.6.4.8 and 12.6.4.9 as follows: 21.6.4.8 Where the calculated point of contraf/exure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318 Sections 21.6.4.1, Items (a) through (c), over the full height of the member. 21.6.4.9 — At any section where the design strength, PPn' of the column is less than the sum of the shears Ve computed in accordance with ACI 318 Sections 21.5.4.1 and 21.6.5.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in AC1318 Sections 21.6.4.1 through 21.6.4.3 shall be provided. For beams framing into opposite sides of the column, the moment components are permitted to be assumed to be of opposite sign. For the determination of the design strength, pPn, of the column, these moments are permitted to be assumed to result from the deformation of the frame in any one principal axis. 1905.1.11 ACI 318, Section 21.9.4. Modify ACI 318, Section 21.9.4, by adding Section 21.9.4.6 as follows: 21.9.4.6 — Walls and portions of walls with P„ > 0.35Po shall not be considered to contribute to the calculated shear strength of the structure for resisting earthquake- induced forces. Such walls shall conform to the requirements of ACI 318 Section 21.13. 1905.1.12 ACI 318, Section 21.11.6. Modify ACI 318, by adding Section 21.11.6.1 as follows: 21.11.6.1 Collector and boundary elements in topping slabs placed over precast floor and roof elements shall not be less than 3 inches (76 mm) or 6 db in thickness, where db is the diameter of the largest reinforcement in the topping slab. RATIONALF- This amendment is intended to carry over critical provisions for the design of concrete columns in moment frames from the legacy 1997 Uniform Building Code. Increased confinement is critical to the integrity of such columns and these modifications ensure that it is provided when certain thresholds are exceeded. In addition, this amendment carries over from the legacy 1997 Uniform Building Code a critical provision for the design of concrete shear walls. It essentially limits the use of very highly gravity - loaded walls in being included in the seismic load resisting system, since their failure could have catastrophic effect on the building. Furthermore, this amendment was incorporated in the code based on observations from the 1994 Northridge Earthquake. Rebar placed in very thin concrete topping slabs have been observed in some instances to have popped out of the slab due to insufficient concrete coverage. This modification ensures that critical boundary and collector rebars are placed in sufficiently thick topping slab to prevent buckling of such reinforcements. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. 2013 LARUCP Recommended Technical Amendments Page 43 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to increase confinement in critical columns, limiting the use of highly gravity loaded walls, and increase concrete coverage in thin slabs will have to prevent failure of the structure and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 44 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -01. Section 2304.9.1 of the 2013 Edition of the California Building Code is amended to read as follows: 2304.9.1 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2301.2. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.9.1. Staple fasteners in Table 2304.9.1 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F. Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official. RATIONALE: Due to the high geologic activities in the Southern California area and the expected higher level of performance on buildings and structures, this proposed local amendment limit the use of staple fasteners in resisting or transferring seismic forces. In September 2007, limited cyclic testing data was provided to the ICC Los Angeles Chapter Structural Code Committee showing that stapled wood structural shear panels do not exhibit the same behavior as the nailed wood structural shear panels. The test results of the stapled wood structural shear panels appeared much lower in strength and drift than the nailed wood structural shear panel test results. Therefore, the use of staples as fasteners to resist or transfer seismic forces shall not be permitted without being substantiated by cyclic testing. This proposed amendment is a continuation of a similar amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to limit the use of staple fasteners to resist or transfer seismic load improve the performance of buildings and structures during a seismic event and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 45 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -02. Section 2304.11.7 of the 2013 Edition of the California Building Code is amended to read as follows: 2304.11.7 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA U1 (Commodity Specifications A or F) for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F. RATIONALE: No substantiating data has been provided to show that wood used in retaining or crib walls are effective in supporting buildings and structures during a seismic event while being subject to deterioration caused by the combined detrimental effect of constant moisture in the soil and wood - destroying organisms. Wood used in retaining or crib walls, when they are not properly treated and protected against deterioration, have performed very poorly. Most contractors are typically accustomed to construction in dry and temperate weather in the Southern California region and are not generally familiar with the necessary precautions and treatment of wood that makes it suitable for both seismic event and wet applications. The proposed amendment takes the precautionary steps to reduce or eliminate potential problems that may result by using wood in retaining or crib walls that experience relatively rapid decay due to the face that the region does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood - destroying organisms. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Climatic and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. In addition, the region is within a climate system capable of producing major winds, fire and rain related disasters, including but not limited to those caused by the Santa Ana winds and El Nino (or La Nina) subtropical -like weather. This region is especially susceptible to more active termite and wood attacking insects and microorganisms. The proposed modification to prohibit the use of wood in retaining or crib walls in an effort to mitigate potential problems or deficiencies due to the proliferation of wood - destroying organisms and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 46 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -03. Section 2305.4 is added to Chapter 23 of the 2013 Edition of the California Building Code to read as follows: 2305.4 Quality of Nails. In Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for hand - driven nails, including diameter, minimum length and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail- head -area ratio of that of the same size hand - driven nails. RATIONALE: The overdriving of nails into the structural wood panel still remains a concern when pneumatic nail guns are used for wood structural panel shear wall nailing. Box nails were observed to cause massive and multiple failures of the typical 3/8 -inch thick plywood during the 1994 Northridge Earthquake. The use of clipped head nails as allowed in Table Al of AFPA SDPWS footnote referencing to ASTM F1667, continues to be restricted from being used in wood structural panel shear walls where the minimum nail head size must be maintained in order to minimize nails from pulling through sheathing materials. Clipped or mechanically driven nails used in wood structural panel shear wall construction were found to perform much less in previous wood structural panel shear wall testing done at the University of California Irvine. The existing test results indicated that, under cyclic loading, the wood structural panel shear walls were less energy absorbent and less ductile. The panels reached ultimate load capacity and failed at substantially less lateral deflection than those using same size hand - driven nails. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require mechanically driven nails to have the same dimensions as hand - driven nail will result in improved quality of construction and performance of wood structural panel shear walls and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 47 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -04. Section 2305.5 is added to Chapter 23 of the 2013 Edition of the California Building Code to read as follows: 2305.5 Hold -down connectors. In Seismic Design Category D, E or F, hold -down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold -down connectors shall be tightened to finger tight plus one half (1/2) wrench turn must prior to covering the wall framing. RATIONALE: ICC -ES AC 155 Acceptance Criteria for Hold -downs (Tie- Downs) Attached to Wood Members is widely used to establish allowable values for hold -down connectors in evaluation reports. AC 155 uses monotonic loading to establish allowable values. Yet, cyclic and dynamic forces imparted on buildings and structures by seismic activity cause more damage than equivalent forces that are applied in a monotonic manner. However, the engineering, regulatory and manufacturing industries have not reached consensus on the appropriate cyclic or dynamic testing protocols. This condition is expected to continue for some time. In the interim, this proposed amendment continues to limit the allowable capacity to 75% of the evaluation report value to provide an additional factor of safety for statically tested anchorage devices. Steel plate washers will reduce the additional damage that can result when hold -down connectors are fastened to wood framing members. This amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles with additional editorial revisions for clarification. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to establish minimum performance requirements for hold -down connectors will reduce failure of wood structural panel shear walls due to excessive deflection and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 48 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -05. Section 2306.2 of the 2013 Edition of the California Building Code is amended to read as follows: 2306.2 Wood -frame diaphragms. Wood -frame diaphragms shall be designed and constructed in accordance with AF &PA SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AF &PA SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B, or C. Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official. The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design. Exception: (DSA -SS, DSA -SS /CC and OSHPD 1, 2 &41 Wood structural panel diaphragms using staples as fasteners are not permitted by DSA and OSHPD. Wood structural panel diaphragms used to resist seismic forces in structures assigned to Seismic Category D, E or F shall be applied directly to the framing members. Exception: Wood structural panel diaphragms are permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking ioints do not coincide. RATIONALE: The Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the damages to buildings and structures during the 1994 Northridge Earthquake recommended reducing allowable shear values in wood structural panel shear walls or diaphragms that were not substantiated by cyclic testing. That recommendation was consistent with a report to the Governor from the Seismic Safety Commission of the State of California recommending that code requirements be "more thoroughly substantiated with testing." The allowable shear values for wood structural panel shear walls or diaphragms fastened with staples are based on monotonic testing and does not take into consideration that earthquake forces load shear wall or diaphragm in a repeating and fully reversible manner. In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with common nails. It was recommended that the use of staples as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category D, E and F unless it can be substantiated by cyclic testing. Furthermore, the cities and county within the Los Angeles region has taken extra measures to maintain the structural integrity of the framing of shear walls and diaphragms designed for high levels of seismic forces by requiring wood sheathing be applied directly over the framing members and prohibiting the use of panels placed over gypsum sheathing. This proposed amendment is intended to prevent the undesirable performance of nails when gypsum board softens due to cyclic earthquake displacements and the nail ultimately does not have any engagement in a solid material within the thickness of the gypsum board. 2013 LARUCP Recommended Technical Amendments Page 49 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM This proposed amendment continues the previous amendment adopted during the 2010 code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to place design and construction limits on staples as fasteners used in wood structural panel or diaphragms not substantiated with cyclic testing will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 50 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -06. Section 2306.3 is amended and Section 2307.2 is added to the 2013 Edition of the California Building Code to read as follows: 2306.3 Wood -frame shear walls. Wood -frame shear walls shall be designed and constructed in accordance with AF &PA SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Tables 4.3A and 4.313 of AF &PA SDPWS shall include the following: 1. Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick and studs shall not be spaced at more than 16 inches on center. 2. The maximum nominal unit shear capacities for 3/8 inch wood structural panels resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 400 pounds per linear foot Lplf�. Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the building official. Where shear design values using allow stress design (ASD) exceed 350 Of or load and resistance factor design (LRFD) exceed 500 plf, all framing members receiving edge nailing from abutting panels shall not be less than a single 3 -inch nominal member, or two 2 -inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Section 4.3.6.1 and 4.3.6.4.3 of AF &PA SDPWS for sill plate size and anchorage requirements. 4. Nails shall be placed not less than 1/2 inch in from the panel edges and not less than 3/8 inch from the edge of the connecting members for shear greater than 350 Of using ASD or 500 Of using LRFD. Nails shall be placed not less than 3/8 inch from panel edges and not less than 1/4 inch from the edge of the connecting members for shears of 350 Of or less using ASD or 500 Of or less using LRFD. 5. Table 4.313 application is not allowed for structures assigned to Seismic Design Category D, E, or F. For structures assigned to Seismic Design Category D, application of Table 4.3C of AF &PA SDPWS shall not be used below the top level in a multi -level building for structures. Where panels are fastened to framing members with staples, requirements and limitations of AF &PA SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B, or C. Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official. The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI /APA PRP -210 shall be permitted to use design values for Plywood Siding in the AF &PA SDPWS. Exception: [DSA -SS 7DSA -SS /CC and OSHPD 1, 2 &4] Wood structural panel shear walls using staples as fasteners are not permitted by DSA and OSHPD. 2307.2 Wood -frame shear walls. Wood -frame shear walls shall be designed and constructed in accordance with Section 2306.3 as applicable. 2013 LARUCP Recommended Technical Amendments Page 51 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM RATIONALE: The Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the damages to buildings and structures during the 1994 Northridge Earthquake recommended reducing allowable shear values in wood structural panel shear walls or diaphragms that were not substantiated by cyclic testing. That recommendation was consistent with a report to the Governor from the Seismic Safety Commission of the State of California recommending that code requirements be "more thoroughly substantiated with testing." The allowable shear values for wood structural panel shear walls or diaphragms fastened with stapled nails are based on monotonic testing and does not take into consideration that earthquake forces load shear wall or diaphragm in a repeating and fully reversible manner. In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with stapled nails would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with stapled nails appeared to be much lower in strength and stiffness than wood structural panels fastened with common nails. It was recommended that the use of stapled nail as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category D, E and F unless it can be substantiated by cyclic testing. Furthermore, the cities and county within the Los Angeles region has taken extra measures to maintain the structural integrity of the framing of shear walls and diaphragms designed for high levels of seismic forces by requiring wood sheathing be applied directly over the framing members and prohibiting the use of panels placed over gypsum sheathing. This proposed amendment is intended to prevent the undesirable performance of nails when gypsum board softens due to cyclic earthquake displacements and the nail ultimately does not have any engagement in a solid material within the thickness of the gypsum board. This proposed amendment continues the previous amendment adopted during the 2010 code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to place design and construction limits on stapled nail fasteners used in wood structural panel shear walls or diaphragms not substantiated with cyclic testing will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 52 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -07. Section 2308.3.4 of Chapter 23 of the 2013 Edition of the California Building Code is amended to read as follows: 2308.3.4 Braced wall line support. Braced wall lines shall be supported by continuous foundations. Exception: For structures with a maximum plan dimension not over 50 feet (15240 mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B, or C. RATIONALE: With the higher seismic demand placed on buildings and structures in this region, interior walls can easily be called upon to resist over half of the seismic loading imposed on simple buildings or structures. Without a continuous foundation to support the braced wall line, seismic loads would be transferred through other elements such as non - structural concrete slab floors, wood floors, etc. The proposed change is to limit the use of the exception to structures assigned to Seismic Design Category A, B or C where lower seismic demands are expected. Requiring interior braced walls be supported by continuous foundations is intended to reduce or eliminate the poor performance of buildings or structures. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. Conventional framing does not address the need for a continuous load path, critical shear transfer mechanisms, connection -ties, irregular and flexible portions of complex shaped structures. The proposed modification to require continuous footings under braced wall lines will improve performance of buildings or structure during a seismic event and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 53 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -08. Section 2308.9.3.1, Section 2308.9.3.2 and Figure 2308.9.3.2 of the 2013 Edition of the California Building Code are amended to read as follow: 2308.9.3.1 Alternative bracing. Any bracing required by Section 2308.9.3 is permitted to be replaced by the following: In one -story buildings, each panel shall have a length of not less than 2 feet 8 inches (813 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with 3/8- inch - minimum - thickness (9.5 mm) wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Table 2304.9.1 and blocked at wood structural panel edges. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32- inch - minimum - thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports. Two anchor bolts installed in accordance with Section 2308.6 shall be provided in each panel. Anchor bolts shall be placed at each panel outside quarter points. Each panel end stud shall have a tie -down device fastened to the foundation, capable of providing an approved uplift capacity of not less than 1,800 pounds (8006 N). The tie -down device shall be installed in accordance with the manufacturer's recommendations. The panels shall be supported directly on a foundation or on floor framing supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12 -inch by 12 -inch (305 mm by 305 mm) continuous footing or turned down slab edge is permitted at door openings in the braced wall line. This continuous footing or turned down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line. 2. In the first story of two -story buildings, each wall panel shall be braced in accordance with Section 2308.9.3.1, Item 1, except that the wood structural panel sheathing shall be provided on both faces, three anchor bolts shall be placed at one - quarter points, and tie -down device uplift capacity shall not be less than 3,000 pounds (13 344 N). 2308.9.3.2 Alternate bracing wall panel adjacent to a door or window opening. Any bracing required by Section 2308.9.3 is permitted to be replaced by the following when used adjacent to a door or window opening with a full - length header: In one -story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8 inch (9.5 mm) minimum thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure 2308.9.3.2. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32- inch - minimum - thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports and in accordance with Figure 2308.9.3.2. The wood structural panel sheathing shall extend up over the solid sawn or glued - laminated header and shall be nailed in accordance with Figure 2308.9.3.2. A built -up header consisting of at least two 2 x 12s and fastened in accordance with Item 24 of Table 2304.9.1 shall be permitted to be used. A spacer, if used, shall be placed on the side of the built -up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full - length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1,000 pounds (4,400 N) shall fasten the header to the inner studs opposite the sheathing. One anchor bolt not less than 5/8 inch (15.9 mm) diameter and installed in accordance with Section 2308.6 shall be 2013 LARUCP Recommended Technical Amendments Page 54 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM provided in the center of each sill plate. The studs at each end of the panel shall have a tie -down device fastened to the foundation with an uplift capacity of not less than 4,200 pounds (18 480 N). Where a panel is located on one side of the opening, the header shall extend between the inside face of the first full - length stud of the panel and the bearing studs at the other end of the opening. A strap with an uplift capacity of not less than 1,000 pounds (4400 N) shall fasten the header to the bearing studs. The bearing studs shall also have a tie -down device fastened to the foundation with an uplift capacity of not less than 1,000 pounds (4400 N). The tie -down devices shall be an embedded strap type, installed in accordance with the manufacturer's recommendations. The panels shall be supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom. Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12 -inch by 12 -inch (305 mm by 305 mm) continuous footing or turned down slab edge is permitted at door openings in the braced wall line. This continuous footing or turned down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line. 2. In the first story of two -story buildings, each wall panel shall be braced in accordance with Item 1 above, except that each panel shall have a length of not less than 24 inches (610 mm). 2013 LARUCP Recommended Technical Amendments Page 55 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM MAIN. WIDTH = 16 " FOR ONE STORY STRUCTURES MIN. WIDTH = 24 " FOR USE IN THE FIRST' OF TWO STORY STRUCTURES MIN. 2x4 FRAMING MIN. 3/6 ' MIN. THICKNESS WOOD, DOUBLE STRUCTURAL PANEL SHEATHING a 2x4 POST MIN. 42007 LB "rIE DOWN DEVICE (EMBEDDED INTO CONCRETE AND NAILED' IINTO FRAMING) SEE SECTION 2306.9.3.2 TYPICAL PORTAL. FRAME CONSTRUCTION FOR A PANEL SPLICE (IF NEEDED), PANEL EDDIES SHALL BE BLOCKED, AND OCCUR WITHIN 24" OF MID- HEIGHT. ONE ROW OF TYP. SHEATHING-TO- FRAMING NAILING IS REQUIRED IF 2x4 BLOCKING IS USED, THE 2X4'3 MUST BE NAILED TOGETHER WITH 3 16D SINKERS MIN. 10001 LB TIE (DOWN DEVICE F "or 5I: I fool = 304.S n m:tl I Inch = 25.4 unni: 1 Pound = 4.448 N. a. For structures assigned to Seismic Design Category Doi E, sheathed on one face with 15132- inclr- minimum- tlrickness {11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 5 inches on panel edges, 12 inches at intermediate supports. FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING RATIONALE: 3/8" thick, 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. 2013 LARUCP Recommended Technical Amendments Page 56 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code EXTENT OF HEADER r ' DOUBLE PORTAL FRAME (TWO BRACED WALL PANELS) �SINGLE EXTENT OF HEADER PORTAL FRAME (ONE BRACED WALLL, PANEL) i • w "I aI MIN. 3" X 11.25 "" NET HEADER G A I« W I. MAIN. WIDTH = 16 " FOR ONE STORY STRUCTURES MIN. WIDTH = 24 " FOR USE IN THE FIRST' OF TWO STORY STRUCTURES MIN. 2x4 FRAMING MIN. 3/6 ' MIN. THICKNESS WOOD, DOUBLE STRUCTURAL PANEL SHEATHING a 2x4 POST MIN. 42007 LB "rIE DOWN DEVICE (EMBEDDED INTO CONCRETE AND NAILED' IINTO FRAMING) SEE SECTION 2306.9.3.2 TYPICAL PORTAL. FRAME CONSTRUCTION FOR A PANEL SPLICE (IF NEEDED), PANEL EDDIES SHALL BE BLOCKED, AND OCCUR WITHIN 24" OF MID- HEIGHT. ONE ROW OF TYP. SHEATHING-TO- FRAMING NAILING IS REQUIRED IF 2x4 BLOCKING IS USED, THE 2X4'3 MUST BE NAILED TOGETHER WITH 3 16D SINKERS MIN. 10001 LB TIE (DOWN DEVICE F "or 5I: I fool = 304.S n m:tl I Inch = 25.4 unni: 1 Pound = 4.448 N. a. For structures assigned to Seismic Design Category Doi E, sheathed on one face with 15132- inclr- minimum- tlrickness {11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 5 inches on panel edges, 12 inches at intermediate supports. FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING RATIONALE: 3/8" thick, 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. 2013 LARUCP Recommended Technical Amendments Page 56 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code r ' 1$ i FASTEN TOP P�ATOE TO HEADER WITH TWO ROWS OF 116D SINKER NAILS AT 3" O.C. TYR 1000 UB STRAP 10100 LB STRAP OPPOSITE SHIEATHIN'G FASTEN SHEATHING TO HEADER WITH 3D COMMON OR • GALVANIZED BOX (NAILS IN 3" GRID PATTERN AS SHOWN AND MAX. •'« 3" O.C. IN ALL FRAMING (STUDS, (BLOCKING, AND SILLS) TYR HEIGHT MAIN. WIDTH = 16 " FOR ONE STORY STRUCTURES MIN. WIDTH = 24 " FOR USE IN THE FIRST' OF TWO STORY STRUCTURES MIN. 2x4 FRAMING MIN. 3/6 ' MIN. THICKNESS WOOD, DOUBLE STRUCTURAL PANEL SHEATHING a 2x4 POST MIN. 42007 LB "rIE DOWN DEVICE (EMBEDDED INTO CONCRETE AND NAILED' IINTO FRAMING) SEE SECTION 2306.9.3.2 TYPICAL PORTAL. FRAME CONSTRUCTION FOR A PANEL SPLICE (IF NEEDED), PANEL EDDIES SHALL BE BLOCKED, AND OCCUR WITHIN 24" OF MID- HEIGHT. ONE ROW OF TYP. SHEATHING-TO- FRAMING NAILING IS REQUIRED IF 2x4 BLOCKING IS USED, THE 2X4'3 MUST BE NAILED TOGETHER WITH 3 16D SINKERS MIN. 10001 LB TIE (DOWN DEVICE F "or 5I: I fool = 304.S n m:tl I Inch = 25.4 unni: 1 Pound = 4.448 N. a. For structures assigned to Seismic Design Category Doi E, sheathed on one face with 15132- inclr- minimum- tlrickness {11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 5 inches on panel edges, 12 inches at intermediate supports. FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING RATIONALE: 3/8" thick, 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. 2013 LARUCP Recommended Technical Amendments Page 56 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification requiring minimum sheathing thickness and nailing type and size will help to maintain minimum quality of construction and performance standards of structures and therefore needs to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 57 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -09. Table 2308.12.4 of the 2013 Edition of the California Building Code is amended to read as follows: TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E (Minimum Percentage of Wall Bracing per each Braced Wall Line a) CONDITION SHEATHING TYPE Sos < 0.50 0.50 < —Sos < 0.75 0.75 <_ So s <_ 1.00 S os > 1.00 One Story G -P° 43 59 75 100 S -Wd 21 32 37 48 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Minimum length of panel bracing of one face of the wall for S -W sheathing shall be at least 4' -0" long or both faces of the wall for G -P sheathing shall be at least 8' -0" long; h/w ratio shall not exceed 2:1. For S -W panel bracing of the same material on two faces of the wall, the minimum length is permitted to be one -half the tabulated value but the h/w ratio shall not exceed 2:1 and design for uplift is required. The 2:1 h/w ratio limitation does not apply to alternate braced wall panels constructed in accordance with Section 2308.9.3.1 or 2308.9.3.2. Wall framing to which sheathing used for bracing is applied shall be nominal 2 inch wide [actual 11/2 inch (38 mm)] or larger members and spaced a maximum of 16 inches on center. Braced wall panel construction types shall not be mixed within a braced wall line. b. G -P = gypsum board, fibeFb9aFd, paFtiGleb9aFd, lath andportland cement plaster or gypsum sheathing boards; S -W = wood structural panels C. Nailing as specified below shall occur at all panel edges at studs, at top and bottom plates and, where occurring, at blocking: For 1/2 -inch gypsum board, 5d (0.113 inch diameter) cooler nails at 7 inches on center; For 5/8 -inch gypsum board, No 11 gage (0.120 inch diameter) cooler nails at 7 inches on center; For gypsum sheathing board, 1 -3/4 inches long by 7/16 -inch head, diamond point galvanized nails at 4 inches on center; For gypsum lath, No. 13 gage (0.092 inch) by 1 -1/8 inches long, 19/64 -inch head, plasterboard at 5 inches on center; For Portland cement plaster, No. 11 gage (0.120 inch) by 11/2 inches long,' /16- inch head at 6 inches on center; Fnr fiherbeaFd and ne4inleb9aFd Ne 11 gage (0.12 innh) by 0 nhec Inns Z/ nnh heerJ el.ieni�erJ neilc et Z innhec n � i�vn� �_ i renter d. S -W sheathing shall be a minimum of 15/32" thick nailed with 8d common placed 3/8 inches from panel edges and spaced not more than 6 inches on center and 12 inches on center along intermediate framing members. RATIONALE: This proposed amendment specifies minimum sheathing thickness and nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands placed on buildings or structure in this region. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. Conventional framing does not address the need for a continuous load path, critical shear transfer mechanisms, connection -ties, irregular and flexible portions of complex shaped structures. The proposed modification to provide specific detailing requirements will improve the performance of buildings and structures and therefore needs to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 58 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP 23 -10. Section 2308.12.5 of the 2013 Edition of the California Building Code is amended to read as follows: 2308.12.5 Attachment of sheathing. Fastening of braced wall panel sheathing shall not be less than that prescribed in Table 2308.12.4 or 2304.9.1. Wall sheathing shall not be attached to framing members by adhesives. Staple fasteners in Table 2304.9.1 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F. Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official. All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels shall be laterally braced at each top corner and at maximum 24 inches (6096 mm) intervals along the top plate of discontinuous vertical framing. RATIONALE: This proposed amendment is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands placed on buildings or structure in this region. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. Conventional framing does not address the need for a continuous load path, critical shear transfer mechanisms, connection -ties, irregular and flexible portions of complex shaped structures. The proposed modification to provide specific detailing requirements will improve the performance of buildings and structures and therefore needs to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Building Code. 2013 LARUCP Recommended Technical Amendments Page 59 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM PART II RECOMMENDED LARUCP AMENDMENTS TO THE 2013 EDITION OF THE CALIFORNIA RESIDENTIAL CODE 2013 LARUCP Recommended Technical Amendments Page 60 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM SUMMARY OF RECOMMENDED LARUCP AMENDMENTS TO THE 2013 CRC (N) 2013 LARUCP NO. (E) 2010 LARUCP NO. TITLE /DESCRIPTION STATUS DATE R3 -01 R3 -01 Amend CRC Section R301.1.3.2 Woodframe Structures R 9/18/12 R3 -02 R3 -02 Add CRC Section R301.1.4 Slopes Steeper Than 33% R 9/18/12 R3 -03 Amend CRC Table 301.2.2.1.1 and Section R301.2.2.1.2 Seismic Design Category N 6/13/13 R3 -04 R3 -03 Amend CRC Section R301.2.2.2.5 Irregular Buildings R 12/18/12 R3 -05 Add CRC Section R301.2.2.3.8 Anchorage of Equipment N 4/10/13 R3 -04 Amend CRC Section R301.2.2.3.5.1 Modify AISI S230 Section B1 D R3 -05 Amend CRC Section R322.1.4.1 Design Flood Elevations D R4 -01 R4 -01 Amend CRC Section R401.1 Foundation Application R 11/6/12 R4 -02 R4 -02 Amend CRC Sections R403.1 General Footings M 11/6/12 R4 -03 R4 -03 Amend CRC Section R404.2 Wood Foundation Walls R 11/6/12 R5 -01 R5 -01 Amend CRC Section R501.1 Application M 4/10/13 R5 -02 R5 -02 Add CRC Section R503.2.4 Openings In Horizontal Diaphragms R 11/6/12 R6 -01 R6 -01 Amend CRC Table R602.3(1) Fastener Schedule M 11/6/12 R6 -02 R6 -02 Amend CRC Table R602.3(2) Alternate Attachment M 11/6/12 R6 -03 R6 -13 Amend CRC Section R602.3.2 Single Top Plate R 11/6/12 R6 -04 R6 -03 Amend CRC Table R602.10.3(3) Bracing Requirement M 11/6/12 R6 -05 Amend CRC Section R602.10.2.3 Minimum Braced Wall Length N 11/6/12 R6 -06 R6 -04 Amend CRC Table R602.10.4 Intermittent Bracing Method R 11/6/12 R6 -07 Amend CRC Table R602.10.5 Braced Wall Lengths N 11/6/12 R6 -08 R6 -05 Amend CRC Figure R602.10.6.1 Alternate Braced Wall Panel R 11/6/12 R6 -09 R6 -06 Amend CRC Figure R602.10.6.2 Portal Frame R 11/6/12 R6 -07 Amend CRC Section R602.10.3.3 Method PFH D R6 -08 Amend CRC Table R602.10.4.1 Continuous Sheathing D R6 -10 R6 -09 Amend CRC Figure R602.10.6.4 Method CS -PF M 11/6/12 R6 -11 R6 -10 Delete CRC Section R602.10.9.1 Braced Wall Panel R 11/6/12 R6 -12 R6 -11 Amend CRC Section R606.2.4 Parapet Walls R 11/6/12 R6 -13 R6 -12 Amend CRC Section R606.12.2.2.3 Reinforcement for Masonry R 11/6/12 R8 -01 R8 -04 Add CRC Section R803.2.4 Openings in Horizontal Diaphragms R 11/27/12 R10 -01 R10 -01 Amend CRC Section R1001.3.1 Vertical Reinforcing R 12/18/12 FOOTNOTE: 1. R = Retain, M = Modify, D = Delete (the existing 2010 LARUCP code amendment), N = New. 2013 LARUCP Recommended Technical Amendments Page 61 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R3 -01. Section R301.1.3.2 of the 2013 Edition of the California Residential Code is amended to read as follows: R301.1.3.2 Woodframe structures gFeateF than *WO StOFies. The building official shall require construction documents to be approved and stamped by a California licensed architect or engineer for all dwellings of woodframe construction more than two stories and basement in height located in Seismic Design Category A, B or C. Notwithstanding other sections of law; the law establishing these provisions is found in Business and Professions Code Section 5537 and 6737.1. The building official shall require construction documents to be approved and stamped by a California licensed architect or engineer for all dwellings of woodframe construction more than one story in height or with a basement located in Seismic Design Category Do, D1 D2 or E. RATIONALE: After the 1994 Northridge Earthquake, the Wood Frame Construction Joint Task Force recommended that the quality of wood frame construction need to be greatly improved. One such recommendation identified by the Task Force is to improve the quality and organization of structural plans prepared by the engineer or architect so that plan examiners, building inspectors, contractors and special inspectors may logically follow and construct the presentation of the seismic force - resisting systems in the construction documents. For buildings or structures located in Seismic Design Category Do, D1, D2 or E that are subject to a greater level of seismic forces, the requirement to have a California licensed architect or engineer prepare the construction documents is intended to minimize or reduce structural deficiencies that may cause excessive damage or injuries in wood frame buildings. Structural deficiencies such as plan and vertical irregularities, improper shear transfer of the seismic force - resisting system, missed details or connections important to the structural system, and the improper application of the prescriptive requirements of the California Residential Code can be readily addressed by a registered design professional. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require construction documents for wood frame construction greater than one story in height or with a basement to be approved and stamped by a California licensed architect or engineer is intended to assure that both the structural design and prescriptive requirement of the code are properly utilized and presented and therefore need to be incorporated into the code to assure that new buildings and structures, and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 62 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R3 -02. Section R301.1.4 is added to Chapter 3 of the 2013 Edition of the California Residential Code to read as follows: R301.1.4 Seismic design provisions for buildings constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope). The design and construction of new buildings and additions to existing buildings when constructed on or into slopes steeper than one unit vertical in three units horizontal (33.3 percent slope) shall comply with Section 1613.9 of the Building Code. RATIONALE: Due to the difficulty of fire suppression vehicles accessing winding and narrow hillside properties and the probabilities for future earthquakes in the Los Angeles region, this technical amendment is required to address the special needs for buildings constructed on hillside locations. A joint Structural Engineers Association of Southern California (SEAOSC) and both the Los Angeles County and Los Angeles City Task Force investigated the performance of hillside building failures after the Northridge earthquake. Numerous hillside failures resulted in loss of life and millions of dollars in damage. These criteria were developed to minimize the damage to these structures and have been in use by both the City and County of Los Angeles for several years with much success. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles. FINDINGS: Local Topographical and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. Additionally, the topography within the Los Angeles region includes significant hillsides with narrow and winding access that makes timely response by fire suppression vehicles challenging and difficult. The proposed modification establishes design parameters to better mitigate and limit property damage that are the results of increased seismic forces which are imparted upon hillside buildings and structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 63 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R03 -03. Table R301.2.2.1.1 and Section R301.2.2.1.2 of the 2013 Edition of the California Residential Code are amended to read as follows: TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION CALCULATED SpS SEISMIC DESIGN CATEGORY SoS <_ 0.17g A 0.17g < SoS <_ 0.33g B 0.33g < SoS <_ 0.50g C 0.50g < SoS <_ 0.67g Do 0.67g < SoS <_ 0.83g D, 0.83g < SpS <_ 45g -1.00g D2 4 g- 1.00g < SpS E R301.2.2.1.2 Alternative determination of Seismic Design Category E. Buildings located in Seismic Design Category E in accordance with Figure R301.2(2) are permitted to be reclassified as being in Seismic Design Category D2 provided one of the following is done: A more detailed evaluation of the seismic design category is made in accordance with the provisions and maps of the California Building Code. Buildings located in Seismic Design Category E per Table R301.2.2.1.1, but located in Seismic Design Category D per the California Building Code, may be designed using the Seismic Design Category D2 requirements of this code. 2. Buildings located in Seismic Design Category E that conform to the following additional restrictions are permitted to be constructed in accordance with the provisions for Seismic Design Category D2 of this code: 2.1.AII exterior shear wall lines or braced wall panels are in one plane vertically from the foundation to the uppermost story. 2.2. Floors shall not cantilever past the exterior walls. 2.3. The building is within all of the requirements of Section R301.2.2.2.5 for being considered as regular. 2.4. For buildings over one story in height, the calculated SpS shall not exceed 1.258. RATIONALE: The purpose of this amendment is to revise the IRC short period design acceleration from 1.25g to 1.0g for SDC D2 as ASCE7 -10 limits the short period acceleration to 1.5g working out to SpS of 1.09; then to limit the SpS to 1.25g for IRC SDC E structure reclassification. Currently, under ASCE 7 -10, SDC D has a wide range from 0.50g <_ SpS and that for regular structures SS may be taken as 1.5g for calculating SpS. This translates to setting a limit of SpS =1.00 9 for regular structure based on ASCE 7. IRC places SpS > 1.25g into SDC E. However, under IRC, structures meeting the regular structure criteria may be re- classified as D2. The limit of 1.25g for the SDC E re- classification in IRC imposes a lower standard for irregular residential structures. This gives a disparity for the equal risk concept in the development of the ASCE 7 -10 seismic hazard maps. ASCE 7 -10 seismic hazard maps have also adjusted SS and S, downward for parts of the middle and eastern United States between 2009 IRC and 2012 IRC. 2013 LARUCP Recommended Technical Amendments Page 64 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM The SDC D2 limit in Table R301.2.2.1.1 is changed to 0.83g < SoS <_ 1.00g. This corresponds to the delineation to a limit of SS of 1.5g for regular structure under ASCE 7 -10. The added exception item 2.4 permits reclassification of SDC E to D2 up to 1.25g. The associate risk for one- and two - family residential regular structure justifies the increase limit of SpS. It is expected that structures beyond the limits set forth will be engineered under IBC provisions. Reference ASCE 7 -10 Section 12.8.1.3 Maximum Ss Value in Determination of Cs For regular structures five stories or less above the base as defined in Section 11.2 and with a period, T, of 0.5s or less, CS is permitted to be calculated using a value of 1.5 for SS. ASCE 7 -10 Section C12.8.1.3 Maximum Ss Value in Determination of Cs. The maximum value of SS was created as hazard maps were revised in 1997. The cap on SS reflects engineering judgment about performance of code - complying buildings in past earthquakes so the structural height, period, and regularity conditions required for use of the limit are very important qualifiers. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the 1994 Northridge Earthquake, the 1987 Whittier Narrows Earthquake, the 1971 San Fernando Earthquake and the 1933 Long Beach Earthquake. This amendment will improve the performance of buildings that otherwise may be designed and constructed in accordance with the CRC during a significant earthquake. This amendment is in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 65 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R3 -04. Items 1, 3 and 5 of Section R301.2.2.2.5 of the 2013 Edition of the California Residential Code are amended to read as follows: 1. When exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required. 3. When the end of a braced wall panel occurs over an opening in the wall below and ends a+ herizental distanne greater than 1 feet (305 mm) from the edge of the opening This pmyisinn is appliGable to sheaF walls and bFaGed wall panels c)#set on plane and to bFaGed wall panels E)#Set E)6[t of plane as permitter) by the eVneptien to item 1 above 5. When portions of a floor level are vertically offset. 2013 LARUCP Recommended Technical Amendments Page 66 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM RATIONALE: With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result by limiting the type of irregular conditions specified in the International Residential Code. Such limitations are intended to reduce the potential structural damage expected in the event of an earthquake. The cities and county of the Los Angeles region has taken extra measures to maintain the structural integrity of the framing of the shear walls and all associated elements when designed for high levels of seismic loads. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed amendment limits the type of irregular conditions within buildings that may lead to higher structural damage during a seismic event and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code and consistent with the requirements in the ASCE 7 -10. 2013 LARUCP Recommended Technical Amendments Page 67 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R3 -05. Section R301.2.2.3.8 is added to Chapter 3 of the 2013 Edition of the California Residential Code to read as follows: R301.2.2.3.8 Anchorage of Mechanical, Electrical, or Plumbing Components and Equipment. Mechanical, electrical, or plumbing components and equipment shall be anchored to the structure. Anchorage of the components and equipment shall be designed to resist loads in accordance with the International Building Code and ASCE 7, except where the component is positively attached to the structure and flexible connections are provided between the component and associated ductwork, piping, and conduit; and either 1. The component weighs 400 lb (1,780 N) or less and has a center of mass located 4 ft (1.22 m) or less above the supporting structure; or 2. The component weighs 20 lb (89N) or less or, in the case of a distributed system, 5 lb/ft (73 N /m) or less. RATIONALE: There is no limitation for weight of mechanical and plumbing fixtures and equipment in the International Residential Code. Requirements from ASCE 7 and the International Building Code would permit equipment weighing up to 400 lbs. when mounted at 4 feet or less above the floor or attic level without engineering design. Where equipment exceeds this requirement, it is the intent of this proposed amendment that a registered design professional be required to analyze if the floor support is adequate and structurally sound. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to limit the equipment weight is intended to reduce injuries, save lives, and minimize structural damages and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 68 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R4 -01. Section R401.1 of the 2013 Edition of the California Residential Code is amended to read as follows: R401.1 Application. The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for all buildings. In addition to the provisions of this chapter, the design and construction of foundations in areas prone to flooding as established by Table R301.2(1) shall meet the provisions of Section R322. Wood foundations shall be designed and installed in accordance with AF &PA PWF. Exception: The provisions of this chapter shall be permitted to be used for wood foundations only in the following situations: 1. In buildings that have no more than two floors and a roof. 2. When interior basement and foundation walls are constructed at intervals not exceeding 50 feet (15 240 mm). Wood foundations in Seismic Design Category Do, D, or D2 shall be designed in onnnrr anno with aGG8pted engineeFing nron+ino not be permitted. Exception: In non - occupied, single- story, detached storage sheds and similar uses other than carport or garage, provided the gross floor area does not exceed 200 square feet, the plate height does not exceed 12 feet in height above the grade plane at any point, and the maximum roof projection does not exceed 24 inches. RATIONALE: No substantiating data has been provided to show that wood foundation is effective in supporting buildings and structures during a seismic event while being subject to deterioration caused by the combined detrimental effect of constant moisture in the soil and wood - destroying organisms. Wood foundation, when they are not properly treated and protected against deterioration, have performed very poorly and have led to slope failures. Most contractors are typically accustomed to construction in dry and temperate weather in the Southern California region and are not generally familiar with the necessary precautions and treatment of wood that makes it suitable for both seismic event and wet applications. The proposed amendment takes the precautionary steps to reduce or eliminate potential problems that may result in using wood foundation that experience relatively rapid decay due to the fact that the region does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood - destroying organisms. However, an exception is made for non - occupied, single -story storage structures that pose significantly less risk to human safety and may utilize the wood foundation guidelines specified in this Chapter. This proposed amendment is a continuation of an amendment adopted during previous code adoption cycles for the California Residential Code. FINDINGS: Local Climatic and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. In addition, the region is within a climate system capable of producing major winds, fire and rain related disasters, including but not limited to those caused by the Santa Ana winds and El Nino (or La Nina) subtropical -like weather. This region is especially susceptible to more active termite and wood attacking insects and microorganisms. The proposed modification to prohibit the use of wood foundation systems as well as limit prescriptive design provisions in an effort to mitigate potential problems or deficiencies due to the proliferation of wood - destroying organisms and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures 2013 LARUCP Recommended Technical Amendments Page 69 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 70 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R4 -02. Sections R403.1.2, R403.1.3 and R403.1.5 of the 2013 Edition of the California Residential Code are amended to read as follows: R403.1.2 Continuous footing in Seismic Design Categories Do, D, and D2. The braced wall panels at exterior walls of buildings located in Seismic Design Categories Do, D, and D2 shall be supported by continuous footings. All required interior braced wall panels in buildings with plan dimensions gFeateF than 50 foot (15240 mm) shall als4a-be supported by continuous footings. R403.1.3 Seismic reinforcing. Concrete footings located in Seismic Design Categories Do, D, and D2, as established in Table R301.2(1), shall have minimum reinforcement. Bottom reinforcement shall be located a minimum of 3 inches (76 mm) clear from the bottom of the footing. In Seismic Design Categories Do, D, and D2 where construction joint is created between a concrete footing and a stem wall, a minimum of one No. 4 bar shall be installed at not more than 4 feet (1219 mm) on center. The vertical bar shall extend to 3 inches (76 mm) clear of the bottom of the footing, have a standard hook and extend a minimum of 14 inches (357 mm) into the stem wall. In Seismic Design Categories Do, D, and D2 where a grouted masonry stem wall is supported on a concrete footing and stem wall, a minimum of one No. 4 bar shall be installed at not more than 4 feet (1219 mm) on center. The vertical bar shall extend to 3 inches (76 mm) clear of the bottom of the footing and have a standard hook. In Seismic Design Categories Do, D, and D2 masonry stem walls without solid grout and vertical reinforcing are not permitted. Exception: In detached one- and two - family dwellings located in Seismic Design Category A, B or C which are three stories or less in height and constructed with stud bearing walls, isolated plain concrete footings, supporting columns or pedestals are permitted. R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10- percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10- percent slope). For structures located in Seismic Design Categories Do D1 or D2, stepped footings shall be reinforced with four No. 4 rebar. Two bars shall be place at the top and bottom of the footings as shown in Figure R403.1.5. �a STEPPED FOUNDATION'S FIGURE R403.1.5 STEPPED FOOTING 2013 LARUCP Recommended Technical Amendments Page 71 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM RATIONALE: With the higher seismic demand placed on buildings and structures in this region, precautionary steps are proposed to reduce or eliminate potential problems that may result for under - reinforced footings located on sloped surfaces. Requiring minimum reinforcement for stepped footings is intended to address the problem of poor performance of plain or under - reinforced footings during a seismic event. Furthermore, interior walls can easily be called upon to resist over half of the seismic loading imposed on simple buildings or structures. Without a continuous foundation to support the braced wall line, seismic loads would be transferred through other elements such as non - structural concrete slab floors, wood floors, etc. The proposed change is to limit the use of the exception to structures assigned to Seismic Design Category A, B or C where lower seismic demands are expected. Requiring interior braced walls be supported by continuous foundations is intended to reduce or eliminate the poor performance of buildings or structures. This proposed amendment is consistent with an amendment adopted during previous code adoption cycles for the California Residential Code. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require continuous footings under braced wall lines, require reinforcement in one- and two - family dwelling, and minimum reinforcement in stepped footings will improve performance of buildings or structure during a seismic event and minimize potential problems or deficiencies and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 72 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R4 -03. Section R404.2 of the 2013 Edition of the California Residential Code is amended to read as follows: R404.2 Wood foundation walls. Wood foundation walls shall be constructed in accordance with the provisions of Sections R404.2.1 through R404.2.6 and with the details shown in Figures R403.1(2) and R403.1(3). Wood foundation walls shall not be used for structures located in Seismic Design Category Dom D1 or D2_ RATIONALE: No substantiating data has been provided to show that wood foundation wall is effective in supporting buildings and structures during a seismic event while being subject to deterioration caused by the combined detrimental effect of constant moisture in the soil and wood - destroying organisms. Wood foundation walls, when they are not properly treated and protected against deterioration, have performed very poorly and have led to slope failures. Most contractors are typically accustomed to construction in dry and temperate weather in the Southern California region and are not generally familiar with the necessary precautions and treatment of wood that makes it suitable for both seismic event and wet applications. The proposed amendment takes the precautionary steps to reduce or eliminate potential problems that may result in using wood foundation walls that experience relatively rapid decay due to the fact that the region does not experience temperatures cold enough to destroy or retard the growth and proliferation of wood - destroying organisms. This proposed amendment is consistent with an amendment adopted during previous code adoption cycles for the California Residential Code. FINDINGS: Local Climatic and Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. In addition, the region is within a climate system capable of producing major winds, fire and rain related disasters, including but not limited to those caused by the Santa Ana winds and El Nino (or La Nina) subtropical -like weather. This region is especially susceptible to more active termite and wood attacking insects and microorganisms. The proposed modification to prohibit the use of wood foundation wall in an effort to mitigate potential problems or deficiencies due to the proliferation of wood - destroying organisms and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 73 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R5 -01. Section R501.1 of the 2013 Edition of the California Residential Code is amended to read as follows: R501.1 Application. The provisions of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces used to house mechanical or plumbing fixtures and equipment. Mechanical or plumbing fixtures and equipment shall be attached (or anchored) to the structure in accordance with Section R301.2.2.3.8 RATIONALE: There is no limitation for weight of mechanical and plumbing fixtures and equipment in the International Residential Code. Requirements from ASCE 7 and the International Building Code would permit equipment weighing up to 400 lbs. when mounted at 4 feet or less above the floor or attic level without engineering design. Where equipment exceeds this requirement, it is the intent of this proposed amendment that a registered design professional is required to analyze if the floor support is adequate and structurally sound. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to limit the equipment weight is intended to reduce injuries, save lives, and minimize structural damages and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 74 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R5 -02. Section R503.2.4 is added to Chapter 5 of the 2013 Edition of the California Residential Code to read as follows: R503.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms with a dimension perpendicular to the moist that is greater than 4 feet (1.2 m) shall be constructed in accordance with Figure R503.2.4. .^" r e' rr ' rr "rr "fr rr X r'Na M TALTIE 1 A, . x 1 1!2 x 4'-(Y MIN., (q.TOTAL) W1 16-46d COMMON INAIbI -S A.S SHOWN •--•m .Ofl. METAL TIE 1 A.x1112 "x(OPENING'WWMTHI +W-O"), MIN,, (2 TOTAL) / 241 116-4 COMMON NAILS Sian SJ: I mdi = 25.4 rm ow, N too -304.K raarru. PLYWOOD SHEATHING ".• r a r r, DIAPHRAGM OPENING A � s" r r r s r 9 r . rr'• , r , i'' ry a. Blockings shall be provided beyond headers. b. Metal ties not less than 0.058 inch [1.47 mm (16 galvanized gage)l by 1.5 inches (38 mm) wide with eight 16d common nails on each side of the header -joist intersection. The metal ties shall have a minimum yield of 33,000 psi (227 MPa). C. Openings in diaphragms shall be further limited in accordance with Section R301.2.2.2.5. FIGURE R503.2.4 OPENINGS IN HORIZONTAL DIAPHRAGMS RATIONALE: Section R502.10 of the Code does not provide any prescriptive criteria to limit the maximum floor opening size nor does Section R503 provide any details to address the issue of shear transfer near larger floor openings. With the higher seismic demand placed on buildings and structures in this region, it is important to ensure that a complete load path is provided to reduce or eliminate potential damages caused by seismic forces. Requiring blocking with metal ties around larger floor openings and limiting opening size is consistent with the requirements of Section R301.2.2.2.5. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require specific detailing at large floor openings is intended to address the poor 2013 LARUCP Recommended Technical Amendments Page 75 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM performance of floor diaphragms with openings and limit or reduce property damages during a seismic event and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 76 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6-01. Lines 37 and 38 of Table R602.3(1) of the 2013 Edition of the California Residential Code are amended to read as follows: TABLE R602.3(1)—conitinuied FASTENER SCHEDULE FOR STRUCTURAL IMEMBERS ForSl: I inch = 25 4 nun, I foot = 304,8 ➢rn, I mile per hour = 0,447 nVs, 11Csi = 6M5 MPa, a. All nails are smooth-connumon, box or deformed shanks except where otherwise stated, Nails used for Framing and sheathing connections shalI have tnijurnum average bending yield m-engths as shown: 80 ksi foi shank diameter oft). 192 inch 120d common Q0 ksi tor shank diameters larger than 0 l42 inch but not larger than 4.x.1'77 inch, and lOO ksi for shank diatmetej,,;ol'O.t42 inch ortless. b. Staples are to gage wire and have, a rifinirnunn '/,,-inch on diameter crown width. c. Nails shall be spaced at not rnore than it inches on centeE at all supports where spans are 48 inches or greaker, cl. rout Riot by 8400t or 4-foot by a)400t 11anclS shall tic applied Neutically, c. Spacing of fasteners not included in this table shall he based on Table R6023(2), E For regions haVin', hasic wind speed of I I0 niph or greater, 8d defornned (2'/," x 0, 120) nails hall he used for attaching plywood and wood stni•turai panel surf sheathing to fnuning within minimum 48 inch distance fronn gable end walls, it'ritean root'height k, more than 25 feet, up to 35 feet maximum. g. For regions having basis wind speed of l(N) mph or less, nails, for anachingwood Q]WtUral panel roof sheathing to gable end wall framing shall he spaced 6 inches on center. When basic wind speed is greater than l00 mph, nails for attaching panel roof sheathing* to intermediate supports shalI be spaced to inches on center for nnininnum 48-inch distance from ridges, eaves and gable end walls; and 4 inches on center to gable end wall frarning. li. Gypsum sheathing shall conform to ASTM C 1396 and shall he installed in accordance with GA 253. I-iherboard sheathing shalI conform to ASTM C 208. i, Spacing offasteriers on flo<)r sheathing panel edges applies to panel edges supported by framing nicinbers and required blocking and at all floor perimeters only Spacing of fasteners on roof sheathing panel edges applies to panel edges supporled by framing member's and required blocking. Blo�cking ol" road Or flool sheathing panel edges poypendiculau to the framing atiernfiseus need not be puovided except as uccluiied by othor provisions of Hats code Flom perimeter diall he supported by frarnm_p members or solid blocking, j, Where, a rafter k, fastened to an adjacent parallel ceiling joist in accordance A ith this schedule, provide two we nails on one side of the rafter and too nails from the ceilingpist to top plate in accordance wifli this schedule, The tare nail on the oppmite side, of the rafter shall not he. required. K. Use of staples in braced wall panels shall be prohibited in Seismic Design Category DO, D1 , or D2. RATIONALE: The Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the damages to buildings and structures during the 1994 Northridge Earthquake recommended reducing allowable shear values in wood structural panel shear walls or diaphragms that were not substantiated by cyclic testing. That recommendation was consistent with a report to the Governor from the Seismic Safety Commission of the State of California recommending that code requirements be "more thoroughly substantiated with testing." The allowable shear values for wood structural panel shear walls or diaphragms fastened with staples are based on monotonic testing and 2013 LARUCP Recommended Technical Amendments Page 77 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code SPACING OF FASTENERS ITEM DESCRIPTION OF 13UILDING MATERIALS DESCRIPTION OF FASTENER' Edges Intermediate supports"' (inches)! (inches) Wood structurall panels, subfiloor, roof and interior walli sheathing to frarning and particleboard wall sheathing to framing 32 31", 6d common 12'" x 0.'l l 3 ") nail � SUN'toor watl)l 6 121 8d common 2Y, x 0.13 l ") nail u rool), 33 9/ 1 8d common nad ('?'J. "° x (k . 13 t ") 6 12' 34 l Y", - l If I Od common tl 3 x 0. 148 ") nail or 6 l "2 4 8d (2'/, " x 0, 13 1 ") defornied nail Otherwalll sheathing' 35 '/2 " SUIWWrat cellulosic galvanized root-ing nad, crown or, I " crown 3 6 fiberboard sheathing stap,le 16 ga , P/4" long 36 2'/12" StRiClUfat CIAL110Sk I''/ I I galvanized rooting nad. crown or, I " crown , 3 6 fiberboard sheathing, staple l6ga, l'/,Iong 37-IL V", gyp"'Unt sheathing" lit, galvanized root-ing nad; staple galvanized, 7 7 long; l✓, screws! Type W or S 38 gyp"'Unt sheathing" galvanized rooting nafl; staple galvanized, 7 7 long; I'/," screws, Type W or S Wood structurall pariells, combination suibfloor underlayrnent to framing 39 7, "and less 611 deformed d 2 " x 0. 120 ") nail or 6 12 8d common � 2'/, "" x 0. 13 1 nail 44) 7/,,, 1,, 8d common (2'/," x 0. 13 1 nail tit 6 V'2 8d deformed t2'/." x 0. 120") nail 41 1 Y", l 1 l0d common 13" x 0, l48 ") nait or 6 12 4 8d deformed Q'I." x 0.120 " "i nail ForSl: I inch = 25 4 nun, I foot = 304,8 ➢rn, I mile per hour = 0,447 nVs, 11Csi = 6M5 MPa, a. All nails are smooth-connumon, box or deformed shanks except where otherwise stated, Nails used for Framing and sheathing connections shalI have tnijurnum average bending yield m-engths as shown: 80 ksi foi shank diameter oft). 192 inch 120d common Q0 ksi tor shank diameters larger than 0 l42 inch but not larger than 4.x.1'77 inch, and lOO ksi for shank diatmetej,,;ol'O.t42 inch ortless. b. Staples are to gage wire and have, a rifinirnunn '/,,-inch on diameter crown width. c. Nails shall be spaced at not rnore than it inches on centeE at all supports where spans are 48 inches or greaker, cl. rout Riot by 8400t or 4-foot by a)400t 11anclS shall tic applied Neutically, c. Spacing of fasteners not included in this table shall he based on Table R6023(2), E For regions haVin', hasic wind speed of I I0 niph or greater, 8d defornned (2'/," x 0, 120) nails hall he used for attaching plywood and wood stni•turai panel surf sheathing to fnuning within minimum 48 inch distance fronn gable end walls, it'ritean root'height k, more than 25 feet, up to 35 feet maximum. g. For regions having basis wind speed of l(N) mph or less, nails, for anachingwood Q]WtUral panel roof sheathing to gable end wall framing shall he spaced 6 inches on center. When basic wind speed is greater than l00 mph, nails for attaching panel roof sheathing* to intermediate supports shalI be spaced to inches on center for nnininnum 48-inch distance from ridges, eaves and gable end walls; and 4 inches on center to gable end wall frarning. li. Gypsum sheathing shall conform to ASTM C 1396 and shall he installed in accordance with GA 253. I-iherboard sheathing shalI conform to ASTM C 208. i, Spacing offasteriers on flo<)r sheathing panel edges applies to panel edges supported by framing nicinbers and required blocking and at all floor perimeters only Spacing of fasteners on roof sheathing panel edges applies to panel edges supporled by framing member's and required blocking. Blo�cking ol" road Or flool sheathing panel edges poypendiculau to the framing atiernfiseus need not be puovided except as uccluiied by othor provisions of Hats code Flom perimeter diall he supported by frarnm_p members or solid blocking, j, Where, a rafter k, fastened to an adjacent parallel ceiling joist in accordance A ith this schedule, provide two we nails on one side of the rafter and too nails from the ceilingpist to top plate in accordance wifli this schedule, The tare nail on the oppmite side, of the rafter shall not he. required. K. Use of staples in braced wall panels shall be prohibited in Seismic Design Category DO, D1 , or D2. RATIONALE: The Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the damages to buildings and structures during the 1994 Northridge Earthquake recommended reducing allowable shear values in wood structural panel shear walls or diaphragms that were not substantiated by cyclic testing. That recommendation was consistent with a report to the Governor from the Seismic Safety Commission of the State of California recommending that code requirements be "more thoroughly substantiated with testing." The allowable shear values for wood structural panel shear walls or diaphragms fastened with staples are based on monotonic testing and 2013 LARUCP Recommended Technical Amendments Page 77 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM does not take into consideration that earthquake forces load shear wall or diaphragm in a repeating and fully reversible manner. In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with common nails. It was recommended that the use of staples as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category Do, D, and D2 unless it can be substantiated by cyclic testing. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to place design and construction limits on staples as fasteners used in wood structural panel or diaphragms not substantiated with cyclic testing will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 78 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -02. Footnote "b" of Table R602.3(2) of the 2013 Edition of the California Residential Code is amended to read as follows: b. Staples shall have a minimum crown width of 7/16 -inch on diameter except as noted. Use of staples in roof, floor, subfloor, and braced wall panels shall be prohibited in Seismic Design Category Do D1, or D2. RATIONALE: The Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the damages to buildings and structures during the 1994 Northridge Earthquake recommended reducing allowable shear values in wood structural panel shear walls or diaphragms that were not substantiated by cyclic testing. That recommendation was consistent with a report to the Governor from the Seismic Safety Commission of the State of California recommending that code requirements be "more thoroughly substantiated with testing." The allowable shear values for wood structural panel shear walls or diaphragms fastened with staples are based on monotonic testing and does not take into consideration that earthquake forces load shear wall or diaphragm in a repeating and fully reversible manner. In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with common nails. It was recommended that the use of staples as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category Do, D, and D2 unless it can be substantiated by cyclic testing. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to place design and construction limits on staples as fasteners used in wood structural panel or diaphragms not substantiated with cyclic testing will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 79 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6-03. Table R602.10.3(3) of the 2013 Edition of the California Residential Code is amended to read as follows: TABLE IR602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY SOI!L CLASS De WALL HEIGHT - 10 FEET 10 PS FLOOR DEAD, LOAD MINIMUM TOTAL LENGTH (FEET)� OF BRACIED WALL PAINELS is PSF R0OFr-EILI1NG, DEAD LOAD REQUIRED ALONG EACH BRACED WALL LINEII BRACIED WALL LINE SPACING < 25 FEET Seismic Design Slary Location Braced WaIll Line ILenigth, Method L11131 Mothod G13 Methods 1 DWB, SIZE, Methadl � Methods CS.WSP, category (feet) Pes, PCP, W" SP CS-G HPS, CS-SFBd_e, 10 25 25 2.5 L6 1.4 20 51) 51) 5.0 3,2 2,7 30 75 75 7.5 4,81 410 W'.0 W.0 10.0 64 5A 50 il 2.5 il 2.5 12.5 8,0, 6,11 10 Nil 45 4.5 3,0 2,6 20 Nil 9,0 9.0, fi'0' 5.1 C (townhou,v s only) 30 Nil il 3.5 13.5 9'0' 73 40 Nil il 8.4:i 18.0 12.0 111.2 50 Nil 22.5 22.5 15,0 l2.8 10 Nil 6,0 6.0, 45 3.X 20 Nil D2.0 12.0 9,0, 7,7 30 Nil il 81. 0 18.0 131.5 11.5 40 Nil 24.0 24.0 18"0 15.3 510 Nil 110,0 30.0 22.5 19.1 10 Nil X5.6 �.8 5.6 L8 L6 20 Nil 11.0 11.0 3,7 3.1 30 41(.1 Nil Nil X16.6 il 1,0 22.0 -16.6 11.0 22.0 5A T2 4.6 6.1 50 Nil X27.6 X 27.6 "fl, 717 10 Nil SNP 5.3 NP 3A "t2 20 Nil SNP 144 NP 75 6A 1.), 30 Nil NP 1 NP i L3 9.6 40 Nil 2i.0 W 2�[.O NP 15,0 12.8 510 Nil NP NP i 81.X l6.0 10 Nil -4-4- NP NP 53 4.5 20 Nil NP 5 LP m0.5 9.0 30 Nil NP 2 4 NP 15,8 13.4 410 Nil 2(.0,0 NP 291.0 NP 2 LO m7.91 9 50 Nil r NP 263 22.3 �CoWiynlcd) 2013 LARUCP Recommended Technical Amendments Page 80 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM TABLE IR02 103(3)-continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY SOIL CLASS D' WALL HEIGHT - 10 FEET 10 PSF FLOOR DEAD LOAD MINIMUM TOTAL LENGTH (FEET) OF BRACED WALL PANELS IS PSF ROOFICIEILIING, DIEAID LOAD REQUIRED ALONG EACH BRACED WALL LINE' BRACIED WALL LINE SPACING < 25 FEET Methods Sei,&rnic Dow"gn Biraced Wall a DWEI, S FIB, Method Methods category Story Location Line Length Method 1-1113' Malhod GE- PBS, PCP,, WSP CS.WSP, (feet) HPS, cs� CS-C SFBI-e 10 Nll 6.0 -4-0-60 10 1.7 261� NIl 6.0 12.0 4- - 4-12.0 4,0 14 3 N13 4.0 18.0 -4-.H-1 8.0 6A 5.1 40 N1) 120-24.0 40 24.0 8,0 (ro .� 50 NI11 30.0 -x{}30.0 10.01 9.51 10 Nll NP 4r44- NP 4,5 31.3 20 NI11 +3-11 NI]) 40 NI]) (0) 7.7 D, 30 Nll ! 90 NI]l 18.0 NP 13.5 115 40 NI11 2 �4.0 NP 18.01 153 50 NI11 49.0 NP ANC' 215 19] 10 NI11 �- NP' A 5 NP 6,0 5.1 '?() NI11 NP !7.O NP 110, 102 30 Nll 2 -5 NP ANC' I N.0 153 40 NI11 3i.0 NP 3i.6 NI]l 24.11 20A 50 Nll 445 NI]l 425 NP 30.11 255 10 NI11 i.0 8.0 4w 8.0 2.5 2.1 20 Nll S. 0 16.0 -9-0X16.0 5A 4.3 30 N1) +"-o 24.0 160 F x24.0 T5 (r .4 40 Nll 32.0 4644-32.0 10.0 9.5 50 Nl�) X00 40.0 X0.0 40.0 125 10,6 10 NI11 NP NP 5.5 4.7 '20 N 1) NP NP 11.01 9.4 30 NI11 -0 2�.5 NP 1'� NP 16.5 14,0 40 N1) 100 N9 ifl.0 NP 220, K7 D, 50 NI11 NP 3�.5 NP �27.5 23A 10 NI' NP N11 Nil NI) N) NI11 NP NP NP Now NI' NP N11 Nil NI) 4 Nl�) NP NP NP' NII) 50 NI' NP N11 Nil NI) 10 Nl�) NP NP T5 6.4 20 NI' NP N11 I5.11 12,8 ClippIevvid] below 30 Nl�) NP NP '225 111,1. one or Rw� -story dweffing 40 NI11 NP NP 30.11 25,,5 50 N 1) NP NP 17.5 31,9 I �or S1: 1 mch = 25.4 mm. I fool. = 305 mm, I pu Pu nd rer square I � Pol = 0A479 Va. a. Linear inierlx+awndiall hu permiued. b. Will bracing, lengths arc 1%aNed on asoil 'rite c l k i s s 1)." Inkrpoliflion o1 hna6ng 1eng1h bowuen dic S,,, Naluacs assmialud lxpffi dic S�i,�ndc Design Calq;{ Tics shall be perniflied when asite-speciffic S,, salxjc i s deters coned ni accordancu wilh Sochon 16 13.3 of the Intemw7avial BOI&ng Co e. c. klethod LIB shag hnie gypsum hoard fingiened to aid k�.6tone side mvfi naih,, or a,crnvs, Nr 3rahlc Itrndm2 .3q I a lorcuenor she,,iffimg or I'ahle R701.3.5 far fiwrior Lypswm boanl. Spnciq af fiWm.,rsw pancU edges shall meet cxcvccl 8 inchcs. d. Method CS-SFB, tip plies inSIX'ConIv. e. Methods GB and PCP braced wall panel lhi.N ratio shall not exceed 1:1 in SDC DO, D1 or D2. Methods DVV3, SFI3, PBS, and HPS are not prernitted in SDC DO, D1 , or D2 2013 LARUCP Recommended Technical Amendments Page 81 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM RATIONALE: Due to the high geologic activities in the Southern California area and the expected higher level of performance on buildings and structures, this proposed local amendment increase the length and limits the location where shear walls sheathed with lath, plaster or gypsum board are used in multi -level buildings. In addition, shear walls sheathed with other materials are prohibited in Seismic Design Category Do, D, and D2 to be consistent with the design limitation for similar shear walls found in the California Building Code. The poor performance of such shear walls in the 1994 Northridge Earthquake was investigated by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Task Force and formed the basis for this proposed amendment. Considering that shear walls sheathed with lath, plaster or gypsum board are less ductile than steel moment frames or wood structural panel shear walls, the cities and county of the Los Angeles region has taken the necessary measures to limit the potential structural damage that may be caused by the use of such walls at the lower level of multi -level building that are subject to higher levels of seismic loads. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to increase the length and limit the location where shear walls sheathed with lath, plaster or gypsum board are used will help to ensure that multi -level building will reach it's performance objective in resisting higher levels of seismic loads and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 82 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -04. Table R602.10.4 of the 2013 Edition of the California Residential Code is amended to read as follows: TABLE R6D2A0.4 BRACING METHODS ? (oronrinuea ) 2013 LARUCP Recommended Technical Amendments Page 83 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code CONNECTION CRITERIA' METHODS, MATERIAL MINIIIROR M THICKNESS FIGURE Fastaalnws spacing 1 x 4 naaaua:ed or Wood, 2-8d ti(cnmion moils Wood: per swd aaiid LIB approved nua°U straps ,at 45` to 60 angles for "� 0r 3 -Sal m 2'1," loo, x 97 113" diaN) mail., wp wid bot'td inL planes t,.ct- in- brAacmn, 1wlctaal: , m axianum 1P °' .I ntNtR1 sp��i,tn�,' Nlel�d strap per nwilNllaac•t1irer strap, 1 " p,.'r nnannatlacturr;r D_04 VE D agolial • /�� "(1 " no lalinial) l ' or maximum 24" � � � � ` -8d (21/, "' hang, x )7, 11 3 " d n,ajl.k Or Pei titud wood hoaJdti wwd w e1n � I Ioll g :lu 1l i N SF 8d common (2 112 "x0.131) nails dry edges 12 ^ field Wxae1 444&4444—'* , "�3P8" edge distance to panel edg-Tr 111011 u l l l l IIIIIIIIIIIIIIIII I _;. wtCNie'maaral i1Fane^l . 1See, ,Section It'1 -AW) 15132" 8d common (2 102"x0.131) nails � . rdery � �s i , . m n �ro � ✓�k 6 edges 12 lvela'9 318" edge distance to panel edge 0F BV -WSE" oM sn- Naculrcal 4" a plane^l'odgc: Panels with stolle 711 , See O igurl: ": B�/'1t_' 11,65 loninion (2a'u," x, I), d It mail t2 w inRh "Tn edi ue or Maslen rr V efleer suppoNs 4 "La hmca 2"tit m See ;Se lion wall IT ane l efld po';ts IZ6 2.1f1.R4.5;V I IP long x.It, tl2 dia. f or' /, thick as F SFB atru� ttliaal 1 of ,`" for s'he aIhiii$2e /a home x 0 12' clitia, 1i5crtnaraial wlwntatiw- maximum I h (h)l (; thick Oc athino_ ",) 3" cd,,Qs' -W livid, wwd wpaeing I -e �'aa1WLanized IkiaAmg ntt N of Xcl A;9'.)nai11111An i n,g I- (�, ro (° 1G7m,� x 91,131' .flat Y ri:Tmls Nmlw or we rewwa per T.ble W42,311) tlair Foe all Ir aced wall GB j e'x [e'r or loo afionN pinet locations- 7 "' Gyp' aini N,?'caral I ,,..., .I dl 4"d"Oe' (inedudi YID" top itnd hottoni plates 7,° Nailk o wrews per ] iahle 87023.5 for .. ante'nor locations ii:eld PBS 1 or tor � For 6d corn nnon 2 long 18d sheathing kmm�eiR {n giro 11 connnniityamis, 3' cd,aex' P,' field ISee Section lfl -AY5;) (2'1," loiig, is 97,1.31 " dia t nails PICT tia ",C Section 1 71136 fG.Yr � 1dbi 1� 1 v 7/"Ir is deadnaitti �, 4YIn Fall dlig911a1'ID Portland ceine m plasx or m axitl uni 16"" smaiel apaaci.ng ... r ' /a," long 16 gage �t aples q at' mothers HP5 1 N�au board / "t4artaaaaxlRltumlda„ GI (0)2 clia.,1B. 25 diaa head nails wwi,Ih ltiln 1 Yh "' ' i4' field al pallet sma111v wm NISI wptilejng l�]1�C11I �td7 to aS,aYbttn1111a,'kl ltc to P7eIl �Rt Daroln into kR �dl edges 6rnatsll l „ F� ;See�:,`ection 1 HY- 1.1C7.a4.1 icy, 4Me',e,tll7n 8602 I().ti..d braced (oronrinuea ) 2013 LARUCP Recommended Technical Amendments Page 83 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM TABLE R602.10.4- onfirnued BRACING METHODS f For SlL l inch = 25.4 ntnn, l fool =:3)5 nvana. 1 a'dll ee = 01!)175 r.a& l hound ]NOT sgl[aa'e'fooa 47.8 N(t ". I mile Nr hour = 0 447 na/s. aa. Adheme ,,maehn ent of w,.dl sheathing., mehidraug Mciho d OII, nail hcgnrrnralcd lan , =kknuc l'k,sagn L ntcgories l , l),,. DI'), .road D,. h. ,App ies to haneds uuc,xt to d,araLe dcor ohc.niaur when supporlmg VaNe end wall or nml load only. May only he Luwc d on one "A "adl of Iht rargc In Seasaunic d)csapn ("tatea r rtes D: " D, and D,' rool covering dead hxn d nrav nod. escecrd 't p,& c. e "anq, ., ivpenandv saLdj.aunt to a Ivf dvxl CS -G l%inea shtadl he frnavidcLd wish ar hcaLlo:r in wcord aunce w6rh D nhlc R502.5( l;). rk full hcajh'I clear opcnnud= shall not he permit'ue d adjacent w as Nleffio'd CS-6 paned. Ld. Method C'S -SFR dhes nw ig3ply do Scmnic Desq ri t "arleprie5 l),,. 'n, and 1), and d in aircns when the %i nd spoe d cncca:& 100 fliph.. e. Nledied applk,, Io adetaa.hcd acne- and ohro- h'auuudy dm,cl an Seismic Design l alegariVS f),, through I), omly. f. Methods GB and PCP braced wall panel hNv ratio shall not exceed 1:1 in SDC DO. D1 . or D2. Methods LIB. UAB. SFB. PBS. HPS. and PFG are not permitted in SDC D0. D1. or D2. g. Use of staples in braced wall panels shall be prohibited in SDC DO, D1 , or D2 RATIONALE: 3/8" thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with 2013 LARUCP Recommended Technical Amendments Page 84 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code CONNECTION CR1TiEREA° METHODS, MATERIAL MINIMUM THICKNESS FIGURE Fasteners Spacing PFH Port at dreine,, '' iffi �/ .. ITT '�%'L" a "aC OI NflbIID 1 f .BLS.. ml). a.. �. 2r1: �°L'N1c1LY Iidj�,�2. Ib. G..dj. 2 ears rtat l-Lh s5r Ylti .� m . Gq c FFa lloilad Inarne at gam+ d / See ih 7CDb➢ R602. 6.3 itlJ . elu +n 1 6C'. I l„ ry.: r '5�.•Sti','SP 8d common (21 f2 "x0.131) nails i l " I m C 30' ed a distance to edge p, I. ".r;:7a7.DI.NaID L11171L1 M1',q'tilla "=L111ce1 44"Grod .. struc'uira"al p an;el 8d 15B2" _ common (2 1 f2 "x0.131) nails _rrorre �� -m, di' "czlges aodcd 3B" ed a distance to panel ed e - _ cs -a:Pe. � D<'r"�110LNlID LIh 1rl51�q ,ln�Lthufl wood Structural l L1ct See Mehxl CS -W SP See, Method CS-VSP A' i,hELL nt hotir L „e 15(32" �n openings O S PF -41 —T d'r'sr�meL�ul�a�i ly tiJ��� "=Lth �'fl SC42 S'cL.fioin 11602, W.6.4 See S,ei.Aion Jik602. 10.6,4 portal fraanu 15(32" tong x 0, l 2 " d aa. (for I /, " phmck sIme lhing „6 C S SFB4 J or "Y tCT =a l "/ It:,lulip x 0 12 'mist. CO anslY ShCc u11Cd niln xiniunl th " � (I'bi N,,” Ihlsla sh alhing) Yedge"s 6" lield: structural lilerlitaard vlud ".haacmiwg gatvwani zed rax)Imra nails or dud con11.nion ('"!," lon,., x 0 13l "' di a) mails, For SlL l inch = 25.4 ntnn, l fool =:3)5 nvana. 1 a'dll ee = 01!)175 r.a& l hound ]NOT sgl[aa'e'fooa 47.8 N(t ". I mile Nr hour = 0 447 na/s. aa. Adheme ,,maehn ent of w,.dl sheathing., mehidraug Mciho d OII, nail hcgnrrnralcd lan , =kknuc l'k,sagn L ntcgories l , l),,. DI'), .road D,. h. ,App ies to haneds uuc,xt to d,araLe dcor ohc.niaur when supporlmg VaNe end wall or nml load only. May only he Luwc d on one "A "adl of Iht rargc In Seasaunic d)csapn ("tatea r rtes D: " D, and D,' rool covering dead hxn d nrav nod. escecrd 't p,& c. e "anq, ., ivpenandv saLdj.aunt to a Ivf dvxl CS -G l%inea shtadl he frnavidcLd wish ar hcaLlo:r in wcord aunce w6rh D nhlc R502.5( l;). rk full hcajh'I clear opcnnud= shall not he permit'ue d adjacent w as Nleffio'd CS-6 paned. Ld. Method C'S -SFR dhes nw ig3ply do Scmnic Desq ri t "arleprie5 l),,. 'n, and 1), and d in aircns when the %i nd spoe d cncca:& 100 fliph.. e. Nledied applk,, Io adetaa.hcd acne- and ohro- h'auuudy dm,cl an Seismic Design l alegariVS f),, through I), omly. f. Methods GB and PCP braced wall panel hNv ratio shall not exceed 1:1 in SDC DO. D1 . or D2. Methods LIB. UAB. SFB. PBS. HPS. and PFG are not permitted in SDC D0. D1. or D2. g. Use of staples in braced wall panels shall be prohibited in SDC DO, D1 , or D2 RATIONALE: 3/8" thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. In September 2007, limited cyclic testing was conducted by a private engineering firm to determine if wood structural panels fastened with staples would exhibit the same behavior as the wood structural panels fastened with common nails. The test result revealed that wood structural panel fastened with staples appeared to be much lower in strength and stiffness than wood structural panels fastened with 2013 LARUCP Recommended Technical Amendments Page 84 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM common nails. It was recommended that the use of staples as fasteners for wood structural panel shear walls or diaphragms not be permitted to resist seismic forces in structures assigned to Seismic Design Category Do, D, and D2 unless it can be substantiated by cyclic testing. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to place design and construction limits on stapled nail fasteners used in wood structural panel shear walls not substantiated with cyclic testing and requiring minimum sheathing thickness and nailing type and size will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 85 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -05. Figure R602.10.6.1 of the 2013 Edition of the California Residential Code is amended to read as follows: 15/32" 1A W11 Ni D ST'RWTU.NRAI PANEL SH1EATHiP+NG ON ONE FACE 010UPLE STUDS RECJ[J1RE"D (2 HrX n [1MINN,I OR I2)STRAP-T'VPE, ANCHORS, PER 'TABLE RBD21^.I 6.1 (Tl OP EkCFA SHOWNFOR CLwRITYt TTRAr-TVPE ANCHORS TSI IAV L RE H "ERp;NMIEQ Ti) BE , ITACHEID OVER THE WOOD 97M)CTURAL FVNF0... PANEL MUST 8E ATTACIIED 70 C( 1 ;R,ETD E DOTI^ G OR COhlkYR "I -E FOkJNJQAT1Q11al INALL C0,14T'1NNlOUSOVER 17bRA(, En N~ Jul I1tiE IIA NuC L LEN•d i3.TI I PER 7AH E R;302,, TOP PLATE SHALL BE CONTINUOUS OVER BRACED WALL PANEL � If w I .II wl FOR PAHEIL, SPLA E: � F HNEEDED'�! ADJ]Cq INITNG PAil IIEL.IE>1Y DES 9°1ALL MIEE'r f';VFRANlQ:l8t F•ASTIF'!.HIF11)1LP 01MIM0114 F RANI IH,JG 8 lewC10Uard0H 0 ,2 GAEY B64X rWLS f:„ 0C, AFIPAKFJ.l.DGE;w.FIyRSINGR.P. STORY'' AND @ 4 0,L" PANEL EDGES FOR THIE IFNRST CF ,T S70R11E,S 51(P108, u. hlt.TF R HEAl'; A Aq RS''�,°Pl AE,,,tt 8D COMMON Q NIAILa @ 12- 0 C „ AT IN1TER11 R S�LIPPO RTS WIMIIr1 RLPIiF°CN IIIPJmNp1 r,01LINeDA'rVa:?I'°1, will F BAR TOP AND 60TTC) rJ LAP 8,4R'5 rA1rN1runU1Aw 24” q(2'M'1YZ DIAHET1ER.ANCIHO'R 14NIINd LIM FOOTIN G S,12,H U PIrM BOLTS LOCATED BETWEE R m 0PLN 1r G Pr,T, 12° T, 13' °. S" A 10 12" Or 4 A r 14 EW 09' .. „, . THE:�ET;;,N�IENT _ FIGURE, IB602 10.6.�1 METHOD ABW ALTIERNATE BRACED WALL, IPANEL RATIONALE: 3/8” thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. 2013 LARUCP Recommended Technical Amendments Page 86 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification requiring minimum sheathing thickness and nailing type and size will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 87 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -06. Figure R602.10.6.2 of the 2013 Edition of the California Residential Code is amended to read as follows: P01d YPCsLL REICHT P�4 iyy H? 6. y EXTENT OF HE'ADERVOTH GO UELE PORT A LFRANES 1,11NO ER. EpWlALLPANEIL$1— GF 11i14 I'll 11 2'40 FINISHED If dJY OF SPLIOE FUM3 SRA,LL � q FR,a11E CONSYRUMON FASTEN S'.H E.2+.7H ING TO HEiQE R V-4 8EP OU1 PORTIIt9G FOR `+I Fde 1..E OR faO III FP.F Pt7 RTA,. R O rm as 4A,ILE'DTOCGtlal V,04 � NUmoBEaivf`.�Wci�4 `G TEYa ION 0TRA?PER E7L0.UCKIING !Ac+VT hPXPM (BMBEOEC INTLI UOPECRE7E ALTO IMLED INTO TAB 1 E RP@ "'111.8 a (CJN HEADER TO fiAE'RZTUG STIRAP PC F TAKE � tldlJ- fill♦= 10'kiT. 0 M1G[ TI'1R Aldp P,OT "T414M uF FL,GTI H�G LA,f'BWftS'Y`r" P60 1054 OIV 5QTH 10 @F hVF fIW'IF.7HIP41.3 R0 'G4'0 F 0 C S4PP MITE SlUE OF — nln»r�iri� ... il! w,,,,,,,,,,,,,,, , Ill EACH PANEL E0 GE - �, EAw714NO1 RATIONALE: hi IPU ry00 N f, PK:A F RAM O N CO'VPR °7 VJITW N1 I;! E nEruEIa,PA1mFL. 15132" �THOC IR dCl0 CI STIR U L C O ORAL PAIY L. SHE AT WIRRG TVP IC AL PLIRT AL SPLIOE FUM3 SRA,LL � q FR,a11E CONSYRUMON FASTEN S'.H E.2+.7H ING TO HEiQE R V-4 8EP 00 CWR OVER A466 EkE. ) COp✓i11O4011GALVANIZEgYd#tX AILSIRI'70Fllb 4A,ILE'DTOCGtlal V,04 � NUmoBEaivf`.�Wci�4 `G PATTERN AS S'HOWm0. E7L0.UCKIING !Ac+VT hPXPM (BMBEOEC INTLI UOPECRE7E ALTO IMLED INTO LL tlfl ITL LE 2;° OF'NE HEADER TO fiAE'RZTUG STIRAP PC F TAKE � tldlJ- fill♦= 10'kiT. 0 M1G[ TI'1R Aldp P,OT "T414M uF FL,GTI H�G LA,f'BWftS'Y`r" P60 1054 OIV 5QTH 10 @F hVF fIW'IF.7HIP41.3 R0 'G4'0 F 0 C Im OPVL y41 E $10F 0" SHEA THIAO CJ `7A.ILM PG OS REOUIRE.D il! ., Ill EACH PANEL E0 GE - �, hi IPU ry00 N f, PK:A F RAM O N CO'VPR °7 VJITW N1 I;! 15132" �THOC IR dCl0 CI STIR U L C O ORAL PAIY L. SHE AT WIRRG TVP IC AL PLIRT AL WEITH POI WOPA Y4 ON OR GALPofMI�.EO SOX `1A19.S AT � q FR,a11E CONSYRUMON O"'0 C IPVALLFA*1R101CTUX ELOCKIN0, D `- n PoolFa El.;.aB �.. . YPly. LE '.4 OATH OF Pawed F I... PE R TAR I F R&OZ.10.5 � NUmoBEaivf`.�Wci�4 `G YIN r7(A2:i0.6 LE�5TRAF -f "r RIF H')LICZ',0 dP7S Tc ca-rEza;EEO�r,ci. irTt's (BMBEOEC INTLI UOPECRE7E ALTO IMLED INTO F'R AHn1d H C'} �RItJ REtlPdPO RO'9H0 OP Pf GPVGMTIE Id dPIE A4 EA7lR' •., TI'1R Aldp P,OT "T414M uF FL,GTI H�G LA,f'BWftS'Y`r" N CTI I1JI 24 Im w_ ...q,. .,« .... ..,. d' .,�.,. .. ,. ,. � _.... a .... .�, .._... "....- ........... ., ---- -- PB IH F00 I'm f SIZE u Z E R CNEFaIm G31d5 Q, K' G2' A11URl ©k`VO4 SLAE SH,'sL_ BE PERRITTED AT NOR OPENINGS. NN 1 1i&e"" ClAVFTERAlNCBgRBOLTIM1ISTA9 .,p.EDPEP P40 1 F 'NY T}H 2" X 2" X W I F" PI .A TF WAS HFR t`RONIIT IFI...ICVATIC N FIGURE 8602.10.6.2 METHOD PFH'— PORTAL FRAME WITH HOLD-DOWNS AT DETACHED GARAGE DOOR OPENINGS e PASTEfl TOP PLATO TO HEADER Nil I'M TWo 0 ROWS LYE M S 1 N KF R PIA N5 AT 15132" MIN �'B'r1WI MTCJp $T RUC'T(IR K.. IP A." I. 'SHEA74114 3/8" thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8" thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. 2013 LARUCP Recommended Technical Amendments Page 88 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification requiring minimum sheathing thickness and nailing type and size will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 89 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6-07. Table R602.10.5 of the 2013 Edition of the California Residential Code is amended to read as follows: TAIBL E R1602.1 0.5 MINIMUM IL ENGTH OF BRACED WALL PANELS METHOD (See Table R,6412,110,411 MINIMUM LENIGTH' (cnchos) CONTRIBUTING LENGTH (inches) Wall Height 8 feet 9 feet 10 feel 11 feet 12 feet I)WrB, 'Sp. S1 „13, plIS, pCp, j..jpS. BV_WSp 44l 48 48 53 58 Actual' 411 48 48 53 58 Doublestdod = Actual I Singk mded = 0,5 Y Actual 1,113 5 62 69 NP NI) Accal” AM I SDC A, R and C, wind.sIved < l m11, nigh 8 32 34 3S 42 48 S DC 1,:1,,,111 aii d 1:1„ , " wind sjx"ed < l W, n1ph "2 32 34 NP I N I) P11 "H Supi-xii-fing fm)l only -fd,241 -1,6=-24 4,�4 4 - L41 -26- L41 48 Stipp- -uflg oiie story and jwd " 24 24 2-4 . 2 7- 29' 48 NX.; '24 27 if), --3,3A .' 36 1. x Act. i 5 ut' CS-G 24 27 if), 313 16 Actual" CS-111: 46-24 +H-24 --afl-24 -4 =L 241 Aduall" Adpnuent clear opening height OiicheO CS 'w CS-SI;J; < 64 '24 27 30 13 36 ALAual" 68 '26 27 if), 13 36 72 27 27 if), 313 36 76 M 29 if), 313 36 911 32 311 30 13 36 84 35 32 32 33 36 98 is 35 33 313 36 92 43 37 35 3,5 36 46 4A 41 38 316 36 100 .......... 44 40 .118 38 104 .......... 49 43 40 39 108 .......... 54 46 43 41 112 .......... .......... 511 45 43 116 .......... .......... 55 49 45 120 .......... .......... 1511 52 48 124 .......... .......... .......... 56 51 129 .......... .......... .......... 6 54 132 .......... .......... .......... 66 58 136 .......... .......... .......... .......... 62 140 .......... .......... .......... .......... 66 144 .......... .......... .......... .......... 72 For,SL I gncfi = 2.,+.4 flim, I dbot = 31,J4.8 mm., I mik per Boor = 0.447 Inis. Nil = Not llernndtcwLl. a. Linciv micipAwum vhall be pennued. h- I �.%e the aelual vdien a k yreaier i h inorequal to the minmium leflyffi. c. Maximum hendur fienpli[ Ivor III] i us 10, lu in avor&flee with I qnue R.02. 10.6.2, but wall heiVhl nm be ineivn�d lo 12 loot xiih pony xafl. d. Maximum raps mm heq,,hi I or T11,4 .; iu 10 lcet in .iocordwxe wash I11 re R602 10.6.3, hw Nv,ffl fieqOiL may be mcrcamal to 12 lees with pany Nvafl. c. Maximum openm� fieq,,hi herd: S -11t k l0 lea in acomIjneu wffli Fqvure R602. 10.6.4, but wall heimht may be inurcawed lo 12 feel Nvith pony wall. 2013 LARUCP Recommended Technical Amendments Page 90 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM RATIONALE: It was observed by the Structural Engineer Association of Southern California (SEAOSC) and the Los Angeles City Task Force that high aspect ratio shear walls experienced many failures during the 1994 Northridge Earthquake. This proposed amendment provides a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment is consistent with an amendment adopted during the previous code adoption cycle for the California Residential Code. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification ensures that the structural integrity with respect to "maximum shear wall aspect ratios" is maintained, therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 91 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -08. Section R602.10.2.3 of the 2013 Edition of the California Residential Code is amended to read as follows: R602.10.2.3 Minimum number of braced wall panels. Braced wall lines with a length of 16 feet (4877 mm) or less shall have a minimum of two braced wall panels of any length or one braced wall panel equal to 48 inches (1219 mm) or more. Braced wall lines greater than 16 feet (4877 mm) shall have a minimum of two braced wall panels. No braced wall panel shall be less than 48 inches in length in Seismic Design Category Do, D1, or D2_ RATIONALE: Plywood shear walls with high aspect ratio experienced many failures during the Northridge Earthquake. This proposed amendment specifies a minimum braced wall length to meet an aspect ratio consistent with other sections of the Residential Code as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge Earthquake. This proposed amendment is consistent with an amendment adopted during previous code adoption cycles for the California Residential Code. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification reduces the aspect ratio help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 92 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -09. Figure R602.10.6.4 of the 2013 Edition of the California Residential Code is amended to read as follows: ,RR'TEnsr �wA,�Rpff,'xn lrxa_,cn.F[�L.IF:, IG a'�tt�,l >kA.�MArt� rrru M.�Rac�r wro,LL a�mv,IF'Lap. Ye'.NAEY V IF HE;rliF ISArH 1WGUL FURTA.L IPNIAML +tE SRX.r EQ M L Fh eL} 4A iINISHED NID HU,, UPEPYNG 9Tf INiLE OR C'.7URE,; PC TAIL TCkA?lI .. ... �........ n. -. WB'Tow M.R 7P�R T?LP gVAL r .......: .. ...:::� .... F VJr VI LL I'MJ gRn.JRIT„ Iq[ F .vlw'Y ; L!F ,"aFd1u.'Bbdl p4 f a--4— %!%! %'111!< % !! %I/l; a ,Tru a n I. �f ...... z l EA P/HT � PANEL, F, '...,4 U A'a'i }«*E,tii'Wdfdf I kEAI? 0014 A Ar . M4 TorrrFi A 7r. Tel rrLM wn N H �GAILVANUIED BOAAaxlLS Vn te. 9RUM zG nFa Fm AnT trAl r,T ;2 {, P^lATTF74 S E'++GNTPa IF dNk EgE!L' FAF'Rk�l rCN'^o-d to IFkYER. er svu EcR1M1f✓E's1 bMRLL "LAIL's rAF ,1 ,7 1'F °�. IHIE.AgPR T INr N.%.it1D STRAFFF.R TFI^iR.E'. ..,... (" I IR 4A tlU pF RrM 7 10 f. 0 611 qC I S OF 5 r'nP DIE N 14 G, AT iF MF To 4 NH'�a Ivem �R .,f; �.HLn rwlnuL.M cod, Vyi Y IS v^ T uru 01 rW WAI II p 15032 it u; IA r, HEIGHT'. PdF rrev� � N h PAN 7 U GFq I,Im t rpw, d V,- 15!32 4i4@-T�C Nf 010 TPI T,ARAL P44EL RL _',IIIr2 ®fO�W vRC. ti yTR.0 -UFAL R"AMIEL SHLA'W d8 lid II'Id CC, .3rmffONOR ALVANCLlr CA:IIGi FRPxFw 5 L'= .T'bING rs +aN w�I Ars °r�m lo- +.IluP aw�sreu a. 9L'aZK1IN1G AND nIW S' R'fH. I'IRCAL R*7Rx44 7 x h N LENa'k Cf '+«4EL PIER, IARL�' F✓IN2 M1P F. Pw Ik�IIE.c�,asaTVS cxl �Vf - $. .... , `V.. p iA .IS N1a1ALLLD LRR0'1A, MT04. "- cuz,-- =;'TF'LM�TG — ITd q U'IWLE�: c'+JST FIIdl ...., 3 "x3 "x0.229" .9 'STIJ kP'ER TABLE5 ,..� r......... A w r,HN IFC.:::1'H PFR OvERCONCRIkTE OR MA1$014RY Ik'II.00K IOUNNAANOR -T-1 ­C1 I s � Fin SL I. Inch = 25A nvnn, I fimt = 31043 nnm FICUIRIE R602.10.6.4 METHOD CS- PIF- CONT'INUOUSILY SHEATHED PORTAL FIRAMIE PANEL CONSTRUCTION RATIONALE: 3/8" thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge 2013 LARUCP Recommended Technical Amendments Page 93 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code �\ 'h L'iq 4T tf T IRAL. PANFIL "w F'ATIW JVi T., T:.d> U"yp f3,m,hlR ndl 'NHArdG FY RJ:N 11111G A7`V%tLbr L46N1 714Z, .. .A taL 3Jb ILH Pb Sau A PCR . A. 4 » T..71.8"ai glleT YFIMN fv HwP.la..;A1,`r eEIE. I1,A1 T' NIII f RIG IR' G 9T'S Lf99 IIV .- „�,�,,^ 'W.� 'R. 4 QIGi,J, tlMRIW,6Af 6' •. T Tr'' GLA.T'E IC IG.IST' ' .. ......... ......... IMI�, u.?FA M�3o4 {o,L W >NLI LreR mr_al. nlw Rr.; rulvds. �....�,. PEP Yil':&A' Rmga..?;x1 I 1 .. ',., PNrr✓FL BAND ` ---- -- eo OOD STAfy.1NUe6LPANI&L&6 6ArGC 'r ........ wUa.r 5TR.4N,„r!JR:A.L .. =C3 L,M rE&VrvaU fJ✓CA n6M1"�F'.f.. "a. 9A.fdLfi 04T,'w?(IH .ITT .......�"'° 1L- oar alrvnLllL,T' OVER RAIS'F 4 'I+N O00 FLOOR . FRAMING ANCHOR op MIN .IC3R'T ',. IRI 10151T 'R. IVY,,En P1.f1,+v `vltL.lw PHtlPar3G L;,.I`4<}7` I.VwP Q ER &KQUR RIPS .r! ✓W) Fin SL I. Inch = 25A nvnn, I fimt = 31043 nnm FICUIRIE R602.10.6.4 METHOD CS- PIF- CONT'INUOUSILY SHEATHED PORTAL FIRAMIE PANEL CONSTRUCTION RATIONALE: 3/8" thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge 2013 LARUCP Recommended Technical Amendments Page 93 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code �\ 4dL L"�1 PLI1 rV,uR:L RIk,4F A7`V%tLbr L46N1 714Z, .A taL 3Jb ILH Pb Sau A PCR fn•. » VAfG, 7I„aJC11ST ern 3R IReM1N Ll$T 'R. 4 QIGi,J, tlMRIW,6Af 6' •. kM'iL PEI'AIL,€' ' .. ......... ......... 1 ` ---- -- eo OOD STAfy.1NUe6LPANI&L&6 6ArGC G ":I. W. b,FI'+'Fk tl'V�v 6a"WL7 !�R RIdA1 ------- �°"�" +4F^' WED RAW 1) .IC3R'T ',. IRI 10151T RA&E 0 F UDOR OVERLAP OPTION G NFM PI& W1L 4tl114, P AM ITVFR Fr01'71 OR, RIIJRO +ARD: F RONT ELLVATIJN SIECTIO,N Fin SL I. Inch = 25A nvnn, I fimt = 31043 nnm FICUIRIE R602.10.6.4 METHOD CS- PIF- CONT'INUOUSILY SHEATHED PORTAL FIRAMIE PANEL CONSTRUCTION RATIONALE: 3/8" thick 3 ply- plywood shear walls experienced many failures during the Northridge Earthquake. Box nails were observed to cause massive and multiple failures of the typical 3/8” thick 3 -ply plywood during the Northridge Earthquake. This proposed amendment specifies minimum sheathing thickness, nail size and spacing so as to provide a uniform standard of construction for designers and buildings to follow. This is intended to improve the performance level of buildings and structures that are subject to the higher seismic demands and reduce and limit potential damages to property. This proposed amendment reflects the recommendations by the Structural Engineers Association of Southern California (SEAOSC) and the Los Angeles City Joint Task Force that investigated the poor performance observed in 1994 Northridge 2013 LARUCP Recommended Technical Amendments Page 93 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM Earthquake. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification requiring minimum sheathing thickness and nailing type and size will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and additions to existing buildings are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 94 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -10. Section R602.10.9.1 of the 2013 Edition of the California Residential Code is deleted in its entirety: RATIONALE: With the higher seismic demand placed on buildings and structures in this region, interior walls can easily be called upon to resist over half of the seismic loading imposed on simple buildings or structures. Without a continuous foundation to support the braced wall line, seismic loads would be transferred through other elements such as non - structural concrete slab floors, wood floors, etc. Requiring interior braced walls be supported by continuous foundations is intended to reduce or eliminate the poor performance of buildings or structures. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require all exterior walls and interior braced wall panels in buildings be supported on continuous footings for a complete load path will improve performance of buildings or structure during a seismic event and therefore, need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 95 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code ■_ ■ ■_ ■ Now a .. ■_ ■ RATIONALE: With the higher seismic demand placed on buildings and structures in this region, interior walls can easily be called upon to resist over half of the seismic loading imposed on simple buildings or structures. Without a continuous foundation to support the braced wall line, seismic loads would be transferred through other elements such as non - structural concrete slab floors, wood floors, etc. Requiring interior braced walls be supported by continuous foundations is intended to reduce or eliminate the poor performance of buildings or structures. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require all exterior walls and interior braced wall panels in buildings be supported on continuous footings for a complete load path will improve performance of buildings or structure during a seismic event and therefore, need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 95 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -11. Section R606.2.4 of the 2013 Edition of the California Residential Code is amended to read as follows: R606.2.4 Parapet walls. Unreinforced solid masonry parapet walls shall not be less than 8 inches (203 mm) thick and their height shall not exceed four times their thickness. Unreinforced hollow unit masonry parapet walls shall be not less than 8 inches (203 mm) thick, and their height shall not exceed three times their thickness. Masonry parapet walls in areas subject to wind loads of 30 pounds per square foot (1.44 kPa) or located in Seismic Design Category Do, D, or D2, or on townhouses in Seismic Design Category C shall be reinforced in accordance with Section R606.12. RATIONALE: The addition of the word "or" will prevent the use of unreinforced parapets in Seismic Design Category Do, D, or D2, or on townhouses in Seismic Design Category C. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to not allow the use of unreinforced masonry is intended to prevent non - ductile failures and sudden structural collapses and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 96 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -12. Section R606.12.2.2.3 of the 2013 Edition of the California Residential Code is amended to read as follows: R606.12.2.2.3 Reinforcement requirements for masonry elements. Masonry elements listed in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown in Figure R606.11(2)R606.11(3) (2)R606.11(3) and in accordance with the following: Horizontal reinforcement. Horizontal joint reinforcement shall consist of Walls not 8XG8e ling it inGhes (102 mm) in width; eF at least one No. 4 bar spaced not more than 48 inches (1219 mm). WheFe twe longitudinal 86 f iffier f�GG8M8Rt aF8 used, th between these wmFes shalethLLwidGst that the meFtaF joint will aGGnmmedate Horizontal reinforcement shall be provided within 16 inches (406 mm) of the top and bottom of these masonry elements. 2. Vertical reinforcement. Vertical reinforcement shall consist of at least one No. 4 bar spaced not more than 48 inches (1219 mm). Vertical reinforcement shall be within 4-&-8 inches (406mm) of the ends of masonry walls. RATIONALE: Reinforcement using longitudinal wires for buildings and structures located in high seismic areas are deficient and not as ductile as deformed rebar. Having vertical reinforcement closer to the ends of masonry walls help to improve the seismic performance of masonry buildings and structures. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to increase reinforcements will ensure that the ductility requirements for buildings in high seismic region meet the intent of the code and limit potential property damages and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 97 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R6 -13. Exception of Section R602.3.2 of the 2013 Edition of the California Residential Code is amended to read as follows: Exception: Aln other than Seismic Design Category Do D1 or D2,a single top plate may be installed in stud walls, provided the plate is adequately tied at joints, corners and interesting walls by a minimum 3- inch -by -6 -inch by a 0.036- inch -thick (76 mm by 152 mm by 0.914 mm) galvanized steel plate that is nailed to each wall or segment of wall by six 8d nails on each side, provided the rafters or joists are centered over the studs with a tolerance of no more than 1 inch (25 mm). The top plate may be omitted over lintels that are adequately tied to adjacent wall sections with steel plates or equivalent as previously described. RATIONALE: The cities and county of the Los Angeles region have taken extra measures to maintain the structural integrity of the framing of the shear wall system for buildings and structures subject to high seismic loads by eliminating single top plate construction. The performance of modern day braced wall panel construction is directly related to an adequate load path extending from the roof diaphragm to the foundation system. A single top plate is likely to be over nailed due to the nailing requirements at a rafter, stud, top plate splice, and braced wall panel edge in a single location. In addition, notching on a single top plate for plumbing, ventilation and electrical wiring may reduce the load transfer capacity of the plate without proper detailing. Majority of buildings and structures designed and built per the California Residential Code with a single top plate may not need structural observation and special inspections. The potential construction mistakes mentioned above could not be caught and corrected by knowledgeable engineers and inspectors, and could jeopardize structural performance of buildings and structures located in high seismic areas. This proposed amendment is a continuation of an amendment adopted during the previous code adoption cycle. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to eliminate the usage of a single top plate will help to maintain minimum quality of construction and performance standards of structures and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 98 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R8 -01. Section R803.2.4 is added to Chapter 8 of the 2013 Edition of the California Residential Code to read as follows: R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall conform with Section R503.2.4. RATIONALE: Section R802 of the Code does not provide any prescriptive criteria to limit the maximum roof opening size nor does Section R803 provide any details to address the issue of shear transfer near larger roof openings. With the higher seismic demand placed on buildings and structures in this region, it is important to ensure that a complete load path is provided to reduce or eliminate potential damages caused by seismic forces. Requiring blocking with metal ties around larger roof openings and limiting opening size is consistent with the requirements of Section R301.2.2.2.5. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to require specific detailing at large roof openings is intended to address the poor performance of roof diaphragms with openings and limit or reduce property damages during a seismic event and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 99 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP R10 -01. Section R1001.3.1 of the 2013 Edition of the California Residential Code is amended to read as follows: R1001.3.1 Vertical reinforcing. For chimneys up to 40 inches (1016 mm) wide, four No. 4 continuous vertical bars adequately anchored into the concrete foundation shall be placed between wythes of solid masonry or within the cells of hollow unit masonry and grouted in accordance with Section R609. Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion. For chimneys more than 40 inches (1016 mm) wide, two additional No. 4 vertical bars adequately anchored into the concrete foundation shall be provided for each additional flue incorporated into the chimney or for each additional 40 inches (1016 mm) in width or fraction thereof. RATIONALE: The performance of fireplace /chimney without anchorage to the foundation has been observed to be inadequate during major earthquakes. The lack of anchorage to the foundation can result in the overturning or displacement of the fireplace /chimney. FINDINGS: Local Geological Conditions — The greater Los Angeles region is a densely populated area having buildings and structures constructed over and near a vast array of fault systems capable of producing major earthquakes, including but not limited to the recent 1994 Northridge Earthquake. The proposed modification to anchor masonry chimneys into concrete foundation will reduce injuries, save lives, and minimize structural damages and therefore needs to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the International Residential Code. 2013 LARUCP Recommended Technical Amendments Page 100 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM PART III RECOMMENDED LARUCP AMENDMENTS TO THE 2013 EDITION OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE (MANDATORY REQUIREMENTS) 2013 LARUCP Recommended Technical Amendments Page 101 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM SUMMARY OF RECOMMENDED LARUCP AMENDMENTS TO THE 2013 CGBSC (N) 2013 LARUCP NO. (E) 2010 LARUCP NO. TITLE /DESCRIPTION STATUS DATE G1 -01 Amend CGBSC Section 101.10 Mandatory and Voluntary Requirements D 5/9/13 G1 -01 G1 -02 Add CGBSC Section 101.12 Fee for Mandatory Measures R 5/9/13 G1 -02 G1 -03 Add CGBSC Section 101. 12.1 Fee for TIER Measures R 5/9/13 G2 -01 Amend CGBSC Section 202 Low -Rise Residential Building Definition D 5/9/13 G2 -01 G2 -02 Amend CGBSC Section 202 Sustainability Definition R 5/9/13 G3 -01 Amend CGBSC Section 301.1 Scope N 5/9/13 G3 -02 Amend CGBSC Section 301.1.1 Additions & Alteration N 5/9/13 G4 -01 Amend CGBSC Section 4.304.1 Irrigation Controller D 5/9/13 G4 -02 Amend CGBSC Section 4.408 Construction Waste Reduction D 5/9/13 G5 -01 Amend CGBSC Section 5.408.3 Excavated Soil and Land Clearing Debris N 5/9/13 G6 -01 Add CGBSC Section 601.1 Reference Organization and Standards Table N 5/9/13 FOOTNOTE: 1. R = Retain, M = Modify, D = Delete (the existing 2010 LARUCP code amendment), N = New. 2013 LARUCP Recommended Technical Amendments Page 102 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G1 -01. Section 101.12 is added to the 2013 Edition of the California Green Building Standards Code to read as follows: 101.12 Fee for Mandatory Measures. A fee of ten percent (10 %) of the plan check /permit fee shall be assessed to verify compliance with the mandatory measure of the California Green Building Standards Code. OR ALTERNATIVELY 2013 LARUCP G1 -01. Section [INSERT NUMBER] is added to the [INSERT NAME OF CITY] Municipal Code to read as follows. [INSERT SECTION NUMBERI Fee for Mandatory Measures. A fee of ten percent (10 %) of the plan check /permit fee shall be assessed to verify compliance with the mandatory measure of the California Green Building Standards Code. RATIONALE: Due to the extra work it will take staff to review and verify compliance with the measures in the new code, a recommended fee of 10% of either the permit and plan check is proposed. While it is understood that each jurisdiction must determine what fee is appropriate for their jurisdiction, the recommended 10% is a starting point. This amount is based upon similar fees assessed for other supplemental reviews or inspection such as accessibility of energy compliance. It may be used as a basis for justifying the proposed fees based upon comparison to other similar fees as indicated above. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 103 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G1 -02. Section 101.12.1 is added to the 2013 Edition of the California Green Building Standards Code to read as follows: 101.12.1 Fee for Tier Measures. When Tier 1 or Tier 2 measures need to be verified by the enforcing aaencv. an additional ten percent (10 %) of the plan check /permit fee may be assessed. OR ALTERNATIVELY 2013 LARUCP G1 -02. Section [INSERT NUMBER] is added to the [INSERT NAME OF CITY] Municipal Code to read as follows. [INSERT SECTION NUMBERI Fee for Tier Measures. When Tier 1 or Tier 2 measures need to be verified by the enforcing agency, an additional ten percent (10 %) of the plan check /permit fee may be assessed. RATIONALE: Due to the extra work it will take staff to review and verify compliance with the measures in the new code, a recommended fee of 10% of either the permit and plan check is proposed. While it is understood that each jurisdiction must determine what fee is appropriate for their jurisdiction, the recommended 10% is a starting point. This amount is based upon similar fees assessed for other supplemental reviews or inspection such as accessibility of energy compliance. It may be used as a basis for justifying the proposed fees based upon comparison to other similar fees as indicated above. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 104 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G2 -01. Section 202 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: SUSTAINABILITY. Consideration of present development and construction impacts on the community, the economy, and the environment without compromising the needs of the future. RATIONALE: The 2013 California Green Building Standards Code contains the word "sustainable" but does not define it. Although it is a term used in association with green building, the word "sustainability ": is often confused to mean the same as green building. The proposed amendment allows clarity and distinguishing understanding while providing for a general definition. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 105 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G3 -01. Section 301.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: 301.1 Scope. Buildings shall be designed to include the green building measures specified as mandatory in the application nhonLrctc nnn4oined in this code. Voluntary green building measures are also included in this code the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless they are adopted by a city or county as specified in Section 101.7. RATIONALE: The proposed editorial change to the indicated section provides clarity and consistency for the application of the CALGreen code. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 106 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G3 -02. Section 301.1.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: Section 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where —the additions o a'ReFations 0 RGF8aS8 the buildiRg'S GOnditioned aFea, volume, oF size. The FequiFement shall apply only to and/o within the cnonifin aF8a of the addition of alteFatiep. Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work. RATIONALE: The purpose of the proposed amendment is to simplify the language and increase the scope of application, thus requiring CALGreen to be applied to all residential projects. California State Housing and Community Development proposed the above 2013 CALGreen code section. The proposed section can only be applied to an existing house only if the volume or size of the condition space is increased. This proposed section, as written, does not encompass interior remodels. The proposed amendment modifies the State language to require additions, alterations, and interior remodels to comply with sections of CALGreen that are relevant to the scope of work. CALGreen and other green building codes have been developed and implemented for some very basic reasons: water, energy, and air quality. The 2010 U.S. Census shows that California has a population of 37.25 million, 13.7 million homes and with ownership at 56.7 %. UCLA Anderson Construction Forecast, a highly recognized authority in predicting the future of construction in the State, has provided the following statistics: 2011 612,000 new homes constructed 2012 763,000 new homes constructed 2013 Just fewer than one million homes will be constructed 2014 1.3 million new homes constructed Total 3.675 million new homes in four years. These simple numbers illustrate that the new homes built in the last four years only equal approximately 9.9% of the total housing stock in the State. These houses comply with the new 2010 Green Standards, but the larger challenge is with the existing housing inventory. The bulk of California's energy is generated by aging power plants. Increasingly, the development and application of alternate energy methods such as photovoltaics has gained market adoption. Coupling these new energy generation processes with new energy saving measures in the 2013 California Energy Code will allow us to potentially offset the need to construct new power plants, which would equate to a savings of billions of tax -payer dollars. Water conservation is another issue being addressed by the new green codes. CALGreen addresses water conservation with requirements for landscape irrigation and plumbing fixtures. In the 2013 code edition kitchen facets will now have to comply with a slightly reduced flow. Starting January 1, 2014 a new State law goes into effect that prohibits the selling of any plumbing fixture that does not conform to the new established flow rates. CALGreen also address's indoor air quality. Within the code there are multiple limits for VOC (volatile organic compounds) in paints, sealants and construction adhesives and formaldehyde contents in composite wood products. These new standards which restrict VOC and formaldehyde contents have shown to improve indoor air quality and minimize or eliminate occupant health issues related to sick building syndrome. 2013 LARUCP Recommended Technical Amendments Page 107 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM FINDINGS: Local Environmental Conditions — The majority of the building stock in the greater Los Angeles region are existing residences. The U.S. Census and the UCLA Anderson Construction Forecast reveal that there are 13.7 million homes in California in 2010, with 2.7 million new homes built in the past three years, illustrates that there are more than five times the number of existing homes as there are new homes built under the CALGreen code. To reduce the impact that the existing housing stock is having on energy, water, and air quality, this amendment proposes to address compliance with the CALGreen code at the time when a permit is issued. There are some estimates that existing buildings account for up to 40% of greenhouse gas emissions. This amendment offset this impact on the communities by implementing the green building measures whenever possible. Any projects that require a permit to be issued will be required to comply with only those sections that are relevant to the scope of work and thereby begin to contribute to improving the environment. This amendment established green building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 108 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G5 -01. Section 5.408.3 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: 5.408.3 Excavated soil and land clearing debris [BSC] 100 percent of trees, stumps, rocks and associated vegetation and soils resulting primarily from land clearing shall be reused or recycled. For a phased project, such material may be stockpiled on site until the storage site is developed. Exception: Reuse, either on -or off -site, of vegetation or soil contaminated by disease or pest infestation. Notes: 1. If contamination by disease or pest infestation is suspected, contact the County Agricultural Commissioner and follow its direction for recycling or disposal of the material. (www.cdfa.ca.gov /exec/ county /county_contacts.html) 2. For a map of known pest and /or disease quarantine zones, consult with the California Department of Food and Agriculture. (www.cdfa.ca.gov) 3. Contaminated soil shall not be reused and shall be disposed of or remediated in accordance with relevant reaulations. RATIONALE: On occasions, projects are proposed on sites where the soil is contaminated and falls outside the scope of a designated authority. The addition of Note #3 provides a mechanism for a local jurisdiction to administer to the removal or remediation of contaminated soils within guidelines established by the city or method developed by the applicant and approved by the local jurisdiction. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 109 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP G6 -01. Section 601.1 is added to the 2013 Edition of the California Green Building Standards Code to read as follows: 601.1. This section lists the organization and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard. RATIONALE: The proposed editorial changes to the table of reference and standards in Chapter 6 have been update to the to 2013 CALGreen code. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 110 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM PART IV RECOMMENDED LARUCP AMENDMENTS TO THE 2013 EDITION OF THE CALIFORNIA GREEN BUILDING STANDARDS CODE (VOLUNTARY REQUIREMENTS) 2013 LARUCP Recommended Technical Amendments Page 111 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM SUMMARY OF RECOMMENDED LARUCP AMENDMENTS TO THE 2013 CGBSC (N) 2013 (E) 2010 TITLE /DESCRIPTION STATUS DATE LARUCP LARUCP NO. NO. GA4 -01 Amend CGBSC Section A4.105.2 Reuse of Materials N 5/9/13 GA4 -02 Amend CGBSC Section A4106.5 Cool Roof for Reduction N 5/9/13 of Heat Island Effect GA4 -03 Amend CGBSC Section A4.303.4 Nonwater Supplied N 5/9/13 Urinals and Waterless Toilets GA4 -04 Amend CGBSC Section A4.404.3 Building Systems N 5/9/13 GA4 -05 Amend CGBSC Section A4.405.1 Prefinished Building N 5/9/13 Materials GA4 -07 Amend CGBSC Section A4.405.4 Use of Building Materials N 5/9/13 From Rapidly Renewable Sources GA4 -08 Amend CGBSC Section A4.407.1 Drainage Around N 5/9/13 Foundation GA4 -09 Amend CGBSC Section A4.408.1 Enhanced Construction N 5/9/13 Waste Reduction GA5 -01 Amend CGBSC Section A5.106.4.1 Short Term Bicycle N 5/9/13 Parking GA5 -02 Amend CGBSC Section A5.106.4.3 Changing Rooms N 5/9/13 GA5 -03 Amend CGBSC Section A5.106.6.1 Reducing Parking N 5/9/13 Capacity GA5 -04 Amend CGBSC Section A5.106.11.2 Cool Roof N 5/9/13 GA5 -05 Amend CGBSC Section A5.406.1 Choice of Materials N 5/9/13 FOOTNOTE: 1. R = Retain, M = Modify, D = Delete (the existing 2010 LARUCP code amendment), N = New. 2013 LARUCP Recommended Technical Amendments Page 112 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -01. Section A4.105.2 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.105.2 Reuse of materials. Use salvaged, refurbished or reused materials for a minimum of 2.5 percent of the total value, based on estimated cost of materials on the project. Materials which can be easily reused include but are not limited to the following: 1. Light fixtures 2. Plumbing fixtures 3. Doors and trim 4. Masonry (reused masonry may only be used for flatwork) 5. Electrical devices 6. Appliances 7. Foundations or portions of foundations Note: Reused material must be in compliance with the appropriate Title 24 requirements. RATIONALE: The current code section provides no guidelines for the percentage of materials to be recycled or reused to achieve compliance with this section. The proposed editorial change provides a minimum percentage of material that must be recycled or reused for the applicant to obtain compliance. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 113 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -02. Section A4.106.5, Table A4.106.5.1(1), Table A4.106.5.1(2), Table A4.106.5.1(3), and Table A4.106.5.1(4) of the 2013 Edition of the California Green Building Standards Code are amended to read as follows: A4.106.5 Cool roof for reduction of heat island effect. Roofing materials for Tier 1 and Tier 2 buildings shall comply with this section: TABLE A4.106.5.1(1) TIER 1 - LOW -RISE RESIDENTIAL TABLE A4.106.5.1(2) TIER 2 - LOW -RISE RESIDENTIAL MINIMUM 3 -YEAR ROOF CLIMATE AGED SOLAR THERMAL SLOPE ZONE REFLECTANCE EMITTANCE SRI < 2:12 13 & 15 0-.-550.63 0.75 64 82 > 2:12 40-15 0.20 0.75 4-627 TABLE A4.106.5.1(2) TIER 2 - LOW -RISE RESIDENTIAL TABLE A4.106.5.1(3) TIER 1 - HIGH -RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS MINIMUM 3 -YEAR ROOF CLIMATE AGED SOLAR THERMAL SLOPE ZONE REFLECTANCE EMITTANCE SRI < 2:12 10&11, 13 15 0.68 85 7-885 > 2:12 2, ^�5 0-30.28 85 2035 TABLE A4.106.5.1(3) TIER 1 - HIGH -RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS TABLE A4.106.5.1(4) TIER 2 - HIGH -RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS MINIMUM 3 -YEAR ROOF CLIMATE AGED SOLAR THERMAL SLOPE ZONE REFLECTANCE EMITTANCE SRI < 2:12 10&11, 13 15 0-.-550.63 0.75 6482 > 2:12 2 - 15 0.20 0.75 4-627 TABLE A4.106.5.1(4) TIER 2 - HIGH -RISE RESIDENTIAL BUILDINGS, HOTELS, AND MOTELS RATIONALE: In tables A4.106.5.1.1, A4.105.1.2, A5.106.1.1, and A5.106.1.2 are indicating new values for Cool roof ratings. These new values for the cool roof rating are not in alignment with standards being proposed by 2013 LARUCP Recommended Technical Amendments Page 114 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code MINIMUM 3 -YEAR ROOF CLIMATE AGED SOLAR THERMAL SLOPE ZONE REFLECTANCE EMITTANCE SRI <2:12 2 15 9660.68 0-.750.85 7-885 > 2:12 2 - 15 0-.230.28 0-.750.85 2035 RATIONALE: In tables A4.106.5.1.1, A4.105.1.2, A5.106.1.1, and A5.106.1.2 are indicating new values for Cool roof ratings. These new values for the cool roof rating are not in alignment with standards being proposed by 2013 LARUCP Recommended Technical Amendments Page 114 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM the California Energy Commission. Tier 1 cool roof values are a prescriptive requirement in the 2008 (current) Building Energy Efficiency Standards, and they have been shown to be cost - effective through studies previously conducted by the California Energy Commission in support of the standards. The proposed editorial changes will bring Chapter 6 and Chapter 11 into alignment and provide consistency for the applicant to achieve compliance with both chapters. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 115 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -03. Section A4.303.4 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.303.4 Nonwater supplied urinals and composting toilets. Nonwater supplied urinals or composting toilets are installed throughout the scope of the permit or comply with Sections 1101.1 thru 1101.8 of the California Civil Code, which ever is the most restrictive. RATIONALE: The proposed code does not stipulate the number of fixtures to be installed to achieve compliance. The proposed editorial change clarifies the quantity of fixtures to be installed to comply with this code section. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 116 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -04. Section A4.404.3 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.404.3 Building systems. Use premanufactured building systems to eliminate solid sawn lumber whenever possible. One or more of the following premanufactured building systems is used throughout: 1. Composite floor joist or premanufactured floor framing system 2. Composite roof rafters or premanufactured roof framing system 3. Panelized (SIPS, ICF or similar) wall framinig system 4. Other methods approved by the enforcing agency RATIONALE: The proposed code does not stipulate the amount of premanufactured components to be installed to achieve compliance. The proposed editorial change clarifies the quantity to be installed to comply with this code section. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 117 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -05. Section A4.405.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.405.1 Prefinished building materials. Utilize prefinished building materials which do not require additional painting or staining when possible. One or more of the following building materials that do not require additional resources for finishing are used: 1. Exterior trim not requiring paint or stain 2. Windows not requiring paint or stain 3. Siding or exterior wall coverings which do not require paint or stain RATIONALE: The application statement allows for the applicant to stipulate that pre- finished materials are not possible and still achieve compliance with the requirement. The editorial change removes the condition and requires compliance to achieve credit. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 118 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -07. Section A4.405.4 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.405.4 Use of building materials from rapidly renewable sources. One or more of the following materials manufactured from rapidly renewable sources or agricultural by- products is used for a minimum of 2.5 percent of the total value, based on estimated cost of materials on the proiect: 1. Insulation 2. Bamboo or cork 3. Engineered products 4. Agricultural based products 5. Other products acceptable to the enforcing agency Note: The intent of this section is to utilize building materials and products which are typically harvested within a 10 -year or shorter cycle RATIONALE: The current code section provides no guidelines for the percentage of materials to be used from rapidly renewable sources. The proposed editorial change provides a minimum percentage of material from a rapidly renewable source that must be use for the applicant to obtain compliance and receive credit. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 119 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -08. Section A4.407.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.407.1 Drainage around foundations. Install foundation and landscape drains which discharge to a dry well, sump, bioswale or other approved on -site location except when not required by state code or locally approved ordinance. RATIONALE: The current language does not take into consideration the requirements of other codes or ordinances. The proposed editorial change addresses the requirements of other codes or ordinances and eliminates an applicant ability to achieve credit while complying with the requirement of another code. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 120 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA4 -09. Sections A4.408.1 and A4.408.1.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A4.408.1 Enhanced construction waste reduction. Nonhazardous construction and demolition debris generated at the site is diverted to recycle or salvage in compliance with one of the following: Tier 1. At least a 65 percent reduction Tier 2. At least a 75 percent reduction RATIONALE: An applicant complying with either TIER 1 or 2 should receive credit for this section because the proposed project meets either of the exceptions. If an applicant is to comply with this section they would need to achieve the stated waste diversion percentages. Any other approach is giving credit for not complying which is not within the scope of the CALGreen code. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 121 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA5 -01. Section A5.106.4.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A5.106.4.1 °°�d—Short -term bicycle parking. If the project is anticipated to generate visitor traffic, Provide permanently anchored bicycle racks within 200 feet of the visitors' entrance, readily visible to Passers-by, for 15 percent of visitor motorized vehicle parking capacity, with a minimum of one two -bike capacity rack. RATIONALE: This current section for bicycle parking only requires 5 percent of the motorized vehicle parking capacity which is equal to mandatory requirement in section 5.106.4.1. The editorial change to 15% increases the requirement and removes the applicant ability to obtain compliance in two different sections. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 122 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA5 -02. Table A5.106.4.3 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A5.106.4.3 Changing rooms. For buildings with over 10 tenant - occupants, provide changing /shower facilities for tenant - occupants only in accordance with Table A5.106.4.3 or document arrangements with nearby changing /shower facilities. TABLE A5.106.4.3 NUMBER OF 2 -TIER (12" X 15" X 72 ") TENANT- SHOWER/CHANGING PERSONAL EFFECTS OCCUPANTS FACILITIES REQUIRED LOCKERS1,2 REQUIRED 0 -10 8 1 unisex shower 1 11 -50 1 unisex shower 2 51 -100 1 unisex shower 3 101 -200 1 shower stall per gender 4 Over 200 1 shower stall per gender for One 2 -tier locker for each each 200 additional tenant- 50 additional tenant - occupants occupants Note: Additional information on recommended bicycle accommodations may be obtained from Sacramento Area Bicycle Advocates RATIONALE: Under the current table the applicant can obtain credit for installing zero changing rooms. By modifying the requirement in the above table, the applicant must install at least one changing room to receive credit for this section. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 123 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA5 -03. Section A5.106.6.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A5.106.6.1 Reduce parking capacity. With the approval of the enforcement authority, employ strategies to reduce on -site parking area by 20% by 1. Use of on street parking or compact spaces, illustrated on the site plan or 2. Implementation and documentation of programs that encourage occupants to carpool, ride share or use alternate transportation. Note: Strategies for programs may be obtained from local TMAs. RATIONALE: This section does not establish a minimum number of reduced parking spaces to achieve compliance, only that the local authority approves the proposed reduction. The editorial change establishes a minimum percentage to achieve a credit for this section. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 124 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA5 -04. Section A5.106.11.2, Table A5.106.11.2.2 and Table A5.106.11.2.3 of the 2013 Edition of the California Green Building Standards Code are amended to read as follows: A5.106.11.2 Cool Roof for reduction of heat island effect. Use roofing materials having a minimum aged solar reflectance and thermal emittance complying with Sections A5.106.11.2.1 and A5.106.11.2.2 or a minimum aged Solar Reflectance Index (SRI) complying with Section A5.106.11.2.3 and as shown in Table A5.106.11.2. 2 for Tier 1 or Table A5.106.11.2.3 for Tier 2. TABLE A5.106.11.2.2 [BSC] TIER 1 TABLE A5.106.11.2.3 TIER 2 MINIMUM 3 -YEAR ROOF CLIMATE AGED SOLAR THERMAL SLOPE ZONE REFLECTANCE EMITTANCE SRI < 2:12 1 - 16 0-.-550.63 0.75 64 82 > 2:12 1 - 16 0.20 0.75 4-627 TABLE A5.106.11.2.3 TIER 2 RATIONALE: In Tables A5.106.11.2.2 and A5.106.11.2.3 are indicating new values for Cool roof ratings. These new values for the cool roof rating are not in alignment with standards being proposed by the California Energy Commission. Tier 1 cool roof values are a prescriptive requirement in the 2008 (current) Building Energy Efficiency Standards, and they have been shown to be cost - effective through studies previously conducted by the California Energy Commission in support of the standards. The proposed editorial changes will bring Chapter 6 and Chapter 11 into alignment and provide consistency for the applicant to achieve compliance with both chapters. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 125 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code MINIMUM 3 -YEAR ROOF CLIMATE AGED SOLAR THERMAL SLOPE ZONE REFLECTANCE EMITTANCE SRI < 2:12 1 - 16 8 0.68 0.85 7-885 > 2:12 1 - 16 0-.300.28 0.85 3035 RATIONALE: In Tables A5.106.11.2.2 and A5.106.11.2.3 are indicating new values for Cool roof ratings. These new values for the cool roof rating are not in alignment with standards being proposed by the California Energy Commission. Tier 1 cool roof values are a prescriptive requirement in the 2008 (current) Building Energy Efficiency Standards, and they have been shown to be cost - effective through studies previously conducted by the California Energy Commission in support of the standards. The proposed editorial changes will bring Chapter 6 and Chapter 11 into alignment and provide consistency for the applicant to achieve compliance with both chapters. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 125 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code FY 2013 LOS ANGELES REGION UNIFORM CODE PROGRAM 2013 LARUCP GA5 -05. Section A5.406.1 of the 2013 Edition of the California Green Building Standards Code is amended to read as follows: A5.406.1 Choice of materials. Compared to other products in a given product category, choose materials proven to be characterized by one or more of the following for a minimum of 5 percent of the total value, based on estimated cost of materials on the project. RATIONALE: The current section does not provide any guidelines for a quantity of materials to achieve compliance. The editorial change establishes a minimum percentage for the different categories located within the section. FINDINGS: Local Administrative Finding — This amendment is necessary for administrative clarification. It does not modify a Building Standards pursuant to Sections 17958 and 18941.5 of the California Health and Safety Code and does not require an express finding to be made pursuant to Sections 17958.5 and 17958.7 of the California Health and Safety Code. This amendment established administrative standards for the effective enforcement of building standards and therefore need to be incorporated into the code to assure that new buildings and structures and additions or alterations to existing buildings or structures are designed and constructed in accordance with the scope and objectives of the California Green Building Standards Code. 2013 LARUCP Recommended Technical Amendments Page 126 of 126 2013 Edition of the California Building Code Final Version: 9/5/2013 2013 Edition of the California Residential Code 2013 Edition of the California Green Building Standards Code