Loading...
HomeMy Public PortalAbout09-213 DPB PROJECT PHASE 1 ATT - 05-23-2013 SD1 (1)T�tic = _ -y,V ,V y _ _ti _ y,-, yy -\ �'�4! CIO 4i F INSTALL MARKER IN A HORIZONTAL LEVEL POSITION. c�q0 F Fc 24" MAX. COVER OVER ECM - - - MINIMUM CONDUIT COVER PRIMARY- 36" �, SECONDARY- 24" 0tin, TELEPHONE- 24" CAP CONDUIT ENDS ELECTRONIC CABLE MARKER INSTALLATION DETAIL 1 \\\, /y/ CONDUIT MIN. COVER FPL SECONDARY- 30" TELEPHONE- 24" CABLE TV- 24" COUNTY TRAFFIC- 30" CONDUIT i INSTALL PULLSTRINGS & SEAL CONDUIT ENDS. GRADE 30" X 48" HH LOAD RATED 20KLB CONDUIT % AT&T HAND HOLE PULL BOX INSTALLATION NOT WITHIN AIA RIGHT-OF-WAY CONDUIT MIN. COVER FPL SECONDARY- 30" TELEPHONE- 24" CABLE TV- 24" COUNTY TRAFFIC- 30" z CONDUIT INSTALL PULLSTRINGS & 1' X 6" CONCRETE COLAR SEAL CONDUIT ENDS. AROUND ALL SIDES 30" X 48" HH LOAD RATED 20KLB CONDUIT � AT&T HAND HOLE/PULL BOX INSTALLATION WITHIN Al A RIGHT—OF—WAY MATERIAL NOTES: 1- FPL TO PROVIDE ALL POWER SYSTEM CONDUIT, BENDS, COUPLINGS, GLUE, HANDHOLES, SPLICE BOXES, PULL BOXES, MARKERS, AND CAPS/PLUGS. FPL TO PROVIDE PRECAST TRANSFORMER PADS, FEEDER SPLICE BOXES, AND SWITCH CHAMBERS. CHAMBERS MAY REQUIRE SOME ASSEMBLY. 2- CONTRACTOR TO PROVIDE PULL STRINGS IN COMCAST AND AT&T CONDUITS AND MISCELLANEOUS CONCRETE IF REQUIRED. 3- ALL CONDUIT, PULL BOXES, GLUE, BENDS, COUPLINGS AND ASSOCIATED MATERIALS FOR ATT AND COMCAST CONDUIT SYSTEM TO BE PROVIDED BY CONTRACTOR. 4- COMCAST TO FURNISH AND INSTALL CATV CABLE AND PEDESTALS. 5- ALL CONTRACTOR PROVIDED MATERIALS TO BE APPROVED BY THE RESPECTIVE UTILITIES PRIOR TO BIDDING THE JOB, PURCHASING THE MATERIALS, OR MATERIAL INSTALLATION. CONTRACTOR TO PROVIDE THE ENGINEER WITH A COPY OF APPROVED CONTRACTOR SUPPLIED MATERIAL LIST PRIOR TO STARTING CONSTRUCTION WITH RESPECTIVE UTIITY SIGNATURES. 6- ALL 100KVA AND 167KVA FPL PADMOUNT TRANSFORMERS TO BE REGULAR STYLE (RS). ALL 25KVA, 50KVA AND 75KVA FPL PADMOUNTED TRANSFORMERS TO BE LOW STYLE. ALL FPL FPL FACILITIES TO BE CONSTRUCTED PER 2010 VERSION OF FPL DISTRIBUTION CONSTRUCTION STANDARDS. CONDUIT LEGEND: LABEL DESCRIPTION 1-4" TRUNK LINE CONDUIT (ATT COLOR GRAY) 2-4" TRUNK LINE CONDUIT (ATT COLOR GRAY) 1-2" TRUNK LINE CONDUIT (ATT COLOR GRAY) 2-2" TRUNK LINE CONDUIT (ATT COLOR GRAY) 1-1" SINGLE RESIDENTIAL SERVICE CONDUIT (ATT COLOR GRAY) ADDITIONAL CONSTRUCTION NOTES: 1. CONTRACTOR TO INSTALL COMCAST AND AT&T CONDUITS WITH END CAPS AND PULL STRINGS. CONTRACTOR TO INSTALL AT&T PULL BOXES. SERVICE CONDUITS TO BE MARKED WITH SERVICE ADDRESS AT PEDESTAL LOCATIONS AND PULL BOXES. 2. COMCAST AND AT&T SINGLE FAMILY SERVICE CONDUITS ARE SCHEDULE 40 PVC OR HDPE 1" NOMINAL DIAMETER MINIMUM WITH 24" MINIMUM COVER. 3. COMCAST CONDUITS SHALL BE COLORED ORANGE AND AT&T CONDUITS SHALL BE COLORED GRAY TO CLEARLY INDICATE WHICH UTILITY THEY ARE FOR. 4. COMCAST CONDUIT RUNS ARE SCHEDULE 40 PVC OR HDPE WITH 24" MINIMUM COVEREXCEPT CONDUITS WITHIN STATE ROAD A1A RIGHT-OF-WAY SHALL HAVE 30" MINIMUM COVER. 5. AT&T CONDUIT RUNS ARE SCHEDULE 40 PVC OR HDPE WITH 24" MINIMUM COVER EXCEPT CONDUITS WITHIN STATE R OAD A1A RIGHT-OF-WAY SHALL HAVE 30" MINIMUM COVER. 6. AT&T PULL BOXES ARE 48"X30" LOAD RATED FOR 20K LBS AND WITH COVERS MARKED AS "TEL". CONDUITS ENTERING FROM THE BOTTOM SHALL HAVE 45 DEGREE BENDS. CONDUITS ENTERING THRU THE SIDE WALLS MAY ENTER WITHOUT BENDS. 7. COMCAST CONDUITS AT ENDS ARE GROUPED TOGETHER, EXTENDED 2" ABOVE GRADE, AND CAPPED TO FACILITATE FUTURE PLACING OF PEDESTALS OVER CONDUITS BY COMCAST. 8. REQUIREMENTS AS INDICATED IN THE RFP/CONTRACT ARE INCLUDED AS PART OF THESE SPECIFICATIONS. THESE DRAWINGS ARE DIAGRAMATIC IN NATURE. ALL DETAILS NECESSARY TO COMPLETE THIS WORK ARE NOT SHOWN ON THESE DRAWINGS. CONTRACTOR IS RESPONSIBLE TO COMPLETE ALL WORK NECESSARY TO COMPLETE THE FACILITIES. CONTRACTOR MUST VISIT THE JOB SITE AND FAMILIARIZE HIMSELF WITH THE PROJECT PRIOR TO BIDDING. 9. CONTRACTOR TO INSTALL FACILITIES TO THE SATISFACTION OF THE RESPECTIVE UTILITIES AND THE ENGINEER. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ANY DAMAGED LANDSCAPING AND/OR HARDSCAPING HE DAMAGES. ADDITIONAL SCREENING LANDSCAPING IS NOT PART OF THIS CONTRACT AND SHALL BE INSTALLED BY OTHERS AS REQUIRED. 11. ALL NEW AT7T AND COMCAST UNDERGROUND SERVICES TO BE RUN TO THE FPL METER LOCATIONS. AT&T SERVICES ARE TO BE CONTINUOUS RUNS FROM THE METER LOCATION TO THE AT&T SPLICE BOX. COMCAST SERVICES ARE TO BE IN CONTINUOUS CONDUIT RUNS FROM THE METER LOCATION TO THE PEDESTAL LOCATION. 12. WHERE EXISTING AT&T AND/OR COMCAST SERVICES ARE IN CONDUIT AND TERMINATE AT THE FPL METER LOCATION, AND ORIGINATE IN THE FRONT OF THE HOUSE, THE EXISTING COUDUIT WILL BE RETAINED AND USED WHERE POSSIBLE AND EXTENDED ALONG THE STREET TO THE SPLICE BOX/PEDESTAL PER THE PLANS. Specifications, Details, and Notes Z � ~ W �ww�W�aw cc z W w¢ o} W o w a_ W Z Z W W Z C, 0- ~¢ W w W Z Z p m W~ W W W = m �30<u- UmdU [-- Z p (n W} W O=~° x p Z a za�w Zi—°F-wz° (-. 0 W W m o J O F- J ¢ H W J n SZU>O W 0 0 :2 ZU1 cnW—W W WL 0 0U0=rZ w W W0W a ZU :2 ? OW W S= a S ki 0 O r 0 Op U1013�HOQ W M 0 a N 0 ' oo C� wct 00 3 tQ a, c 00 U Cq 0 v a o LL- rT1 w � w � z 0 U) a J J 0 Q 0 LL- cn z 0 Q � � z 0 0 � 0 a 0 a 0 o' w 0 U) o 0 z N z w Qo �z2-- w :C) O o CD H o Qoo�m F-- Z Z p 29 U Z O ��QUJU r L/ QU (5 Q ��w�SOR N � z W < � W w000�z =z�==o m�U Baa O m 12 Q, � a� z ca = m ° .� 4 o 2 aial Qa o E ._ C, m:S O 0- U i >a Q�:6)Ezx Imo— o 0 .co a 2 u) Date: 5/25/13 Scale: AS NOTED Drawn: DPB Checked: DPB Job # 2009—GS Sheet SD I Of 27 Sheets