HomeMy Public PortalAbout09-213 DPB PROJECT PHASE 1 ATT - 05-23-2013 SD1 (1)T�tic = _ -y,V ,V y
_ _ti _ y,-, yy
-\ �'�4!
CIO
4i F INSTALL MARKER IN A
HORIZONTAL LEVEL POSITION.
c�q0
F
Fc 24" MAX. COVER
OVER ECM
- - - MINIMUM CONDUIT COVER
PRIMARY- 36"
�, SECONDARY- 24"
0tin, TELEPHONE- 24"
CAP CONDUIT ENDS
ELECTRONIC CABLE MARKER
INSTALLATION DETAIL
1 \\\, /y/
CONDUIT MIN. COVER
FPL SECONDARY- 30"
TELEPHONE- 24"
CABLE TV- 24"
COUNTY TRAFFIC- 30"
CONDUIT
i
INSTALL PULLSTRINGS &
SEAL CONDUIT ENDS.
GRADE
30" X 48" HH
LOAD RATED 20KLB
CONDUIT %
AT&T HAND HOLE PULL BOX INSTALLATION
NOT WITHIN AIA RIGHT-OF-WAY
CONDUIT MIN. COVER
FPL SECONDARY- 30"
TELEPHONE- 24"
CABLE TV- 24"
COUNTY TRAFFIC- 30"
z CONDUIT
INSTALL PULLSTRINGS & 1' X 6" CONCRETE COLAR
SEAL CONDUIT ENDS. AROUND ALL SIDES
30" X 48" HH
LOAD RATED 20KLB
CONDUIT �
AT&T HAND HOLE/PULL BOX INSTALLATION
WITHIN Al A RIGHT—OF—WAY
MATERIAL NOTES:
1- FPL TO PROVIDE ALL POWER SYSTEM CONDUIT,
BENDS, COUPLINGS, GLUE, HANDHOLES, SPLICE BOXES,
PULL BOXES, MARKERS, AND CAPS/PLUGS. FPL TO PROVIDE
PRECAST TRANSFORMER PADS, FEEDER SPLICE BOXES,
AND SWITCH CHAMBERS. CHAMBERS MAY REQUIRE SOME
ASSEMBLY.
2- CONTRACTOR TO PROVIDE PULL STRINGS IN
COMCAST AND AT&T CONDUITS AND MISCELLANEOUS
CONCRETE IF REQUIRED.
3- ALL CONDUIT, PULL BOXES, GLUE, BENDS, COUPLINGS
AND ASSOCIATED MATERIALS FOR ATT AND COMCAST
CONDUIT SYSTEM TO BE PROVIDED BY CONTRACTOR.
4- COMCAST TO FURNISH AND INSTALL CATV CABLE
AND PEDESTALS.
5- ALL CONTRACTOR PROVIDED MATERIALS TO BE
APPROVED BY THE RESPECTIVE UTILITIES PRIOR TO
BIDDING THE JOB, PURCHASING THE MATERIALS, OR
MATERIAL INSTALLATION. CONTRACTOR TO PROVIDE THE
ENGINEER WITH A COPY OF APPROVED CONTRACTOR
SUPPLIED MATERIAL LIST PRIOR TO STARTING
CONSTRUCTION WITH RESPECTIVE UTIITY SIGNATURES.
6- ALL 100KVA AND 167KVA FPL PADMOUNT
TRANSFORMERS TO BE REGULAR STYLE (RS). ALL 25KVA,
50KVA AND 75KVA FPL PADMOUNTED TRANSFORMERS TO
BE LOW STYLE. ALL FPL FPL FACILITIES TO BE
CONSTRUCTED PER 2010 VERSION OF FPL DISTRIBUTION
CONSTRUCTION STANDARDS.
CONDUIT LEGEND:
LABEL DESCRIPTION
1-4"
TRUNK LINE CONDUIT
(ATT COLOR GRAY)
2-4"
TRUNK LINE CONDUIT
(ATT COLOR GRAY)
1-2"
TRUNK LINE CONDUIT
(ATT COLOR GRAY)
2-2"
TRUNK LINE CONDUIT
(ATT COLOR GRAY)
1-1"
SINGLE RESIDENTIAL SERVICE CONDUIT (ATT COLOR GRAY)
ADDITIONAL CONSTRUCTION NOTES:
1. CONTRACTOR TO INSTALL COMCAST AND AT&T CONDUITS WITH END CAPS AND PULL
STRINGS. CONTRACTOR TO INSTALL AT&T PULL BOXES. SERVICE CONDUITS TO BE
MARKED WITH SERVICE ADDRESS AT PEDESTAL LOCATIONS AND PULL BOXES.
2. COMCAST AND AT&T SINGLE FAMILY SERVICE CONDUITS ARE SCHEDULE 40 PVC OR
HDPE 1" NOMINAL DIAMETER MINIMUM WITH 24" MINIMUM COVER.
3. COMCAST CONDUITS SHALL BE COLORED ORANGE AND AT&T CONDUITS SHALL BE
COLORED GRAY TO CLEARLY INDICATE WHICH UTILITY THEY ARE FOR.
4. COMCAST CONDUIT RUNS ARE SCHEDULE 40 PVC OR HDPE WITH 24" MINIMUM
COVEREXCEPT CONDUITS WITHIN STATE ROAD A1A RIGHT-OF-WAY SHALL HAVE 30"
MINIMUM COVER.
5. AT&T CONDUIT RUNS ARE SCHEDULE 40 PVC OR HDPE WITH 24" MINIMUM COVER
EXCEPT CONDUITS WITHIN STATE R OAD A1A RIGHT-OF-WAY SHALL HAVE 30" MINIMUM
COVER.
6. AT&T PULL BOXES ARE 48"X30" LOAD RATED FOR 20K LBS AND WITH COVERS
MARKED AS "TEL". CONDUITS ENTERING FROM THE BOTTOM SHALL HAVE 45 DEGREE
BENDS. CONDUITS ENTERING THRU THE SIDE WALLS MAY ENTER WITHOUT BENDS.
7. COMCAST CONDUITS AT ENDS ARE GROUPED TOGETHER, EXTENDED 2" ABOVE
GRADE, AND CAPPED TO FACILITATE FUTURE PLACING OF PEDESTALS OVER CONDUITS
BY COMCAST.
8. REQUIREMENTS AS INDICATED IN THE RFP/CONTRACT ARE INCLUDED AS PART OF
THESE SPECIFICATIONS. THESE DRAWINGS ARE DIAGRAMATIC IN NATURE. ALL DETAILS
NECESSARY TO COMPLETE THIS WORK ARE NOT SHOWN ON THESE DRAWINGS.
CONTRACTOR IS RESPONSIBLE TO COMPLETE ALL WORK NECESSARY TO COMPLETE
THE FACILITIES. CONTRACTOR MUST VISIT THE JOB SITE AND FAMILIARIZE HIMSELF
WITH THE PROJECT PRIOR TO BIDDING.
9. CONTRACTOR TO INSTALL FACILITIES TO THE SATISFACTION OF THE RESPECTIVE
UTILITIES AND THE ENGINEER.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ANY DAMAGED
LANDSCAPING AND/OR HARDSCAPING HE DAMAGES. ADDITIONAL SCREENING
LANDSCAPING IS NOT PART OF THIS CONTRACT AND SHALL BE INSTALLED BY OTHERS
AS REQUIRED.
11. ALL NEW AT7T AND COMCAST UNDERGROUND SERVICES TO BE RUN TO THE FPL
METER LOCATIONS. AT&T SERVICES ARE TO BE CONTINUOUS RUNS FROM THE METER
LOCATION TO THE AT&T SPLICE BOX. COMCAST SERVICES ARE TO BE IN CONTINUOUS
CONDUIT RUNS FROM THE METER LOCATION TO THE PEDESTAL LOCATION.
12. WHERE EXISTING AT&T AND/OR COMCAST SERVICES ARE IN CONDUIT AND
TERMINATE AT THE FPL METER LOCATION, AND ORIGINATE IN THE FRONT OF THE
HOUSE, THE EXISTING COUDUIT WILL BE RETAINED AND USED WHERE POSSIBLE AND
EXTENDED ALONG THE STREET TO THE SPLICE BOX/PEDESTAL PER THE PLANS.
Specifications, Details, and Notes
Z
� ~ W
�ww�W�aw
cc z W w¢ o} W o w a_ W
Z Z W W Z
C,
0-
~¢ W w
W Z Z p m W~ W W W = m
�30<u- UmdU [--
Z p (n W} W O=~° x p Z
a za�w Zi—°F-wz°
(-. 0 W W m o J O F- J ¢ H
W J n
SZU>O W 0 0 :2 ZU1
cnW—W W WL 0 0U0=rZ
w W W0W a
ZU :2
? OW W S= a S ki 0 O r 0
Op U1013�HOQ W M 0
a N
0
' oo
C� wct
00
3 tQ a,
c 00
U Cq 0
v
a
o
LL-
rT1
w
�
w
�
z
0
U)
a
J
J
0 Q
0
LL-
cn z
0
Q �
� z
0 0
� 0
a
0
a
0
o'
w
0
U)
o
0
z
N
z w
Qo
�z2--
w :C)
O
o CD
H o
Qoo�m
F--
Z Z
p 29 U Z
O
��QUJU
r
L/
QU
(5
Q
��w�SOR
N �
z
W < � W
w000�z
=z�==o
m�U
Baa
O
m
12 Q, � a�
z ca = m ° .� 4
o 2 aial Qa o E
._ C, m:S O 0- U
i
>a
Q�:6)Ezx
Imo— o 0 .co a 2 u)
Date: 5/25/13
Scale: AS NOTED
Drawn: DPB
Checked: DPB
Job # 2009—GS
Sheet
SD I
Of 27 Sheets