Loading...
HomeMy Public PortalAboutFPL Ferdon Street Lighting AgreementFirst Revised Sheet No. 9.140 FLORIDA POWER & LIGHT COMPANY Cancels Original Sheet 9.140 FPL Account Number: NEW FPL Work Request Number. 10796783 LIGHTING AGREEMENT In accordance with the following terms and conditions. City of Crestview (hereinafter called the Customer), requests on this day of 29 June 2022 , from FLORIDA POWER & LIGHT COMPANY (hereinafter called FPL), a corporation organized and existing under the laws of the State of Florida, the following installation or modification of lighting facilities at (general boundaries) Ferdon Blvd- Hwy 90 to Commerce Dr _, located in Crestview , Florida. (a) Installation and/or removal of FPL-owned facilities described as follows: Fixture Description (1) ATB2 186W ATB2 264W Color # # Watts Lumens Temperature Installed Removed 186 25839 4000 12 264 33907 4000 3 (1) Catalog of available fixtures and the assigned billing tier for each can be viewed at (Continued on Sheet No. 9.141) Issued by: Tiffany Cohen, Senior Director, Regulatory Rates, Cost of Service and Systems Effective: January 1, 2022 Second Revised Sheet No. 9.141 FLORIDA POWER & LIGHT COMPANY Cancels First Sheet No. 9.141 (Continued from Sheet No. 9.140) Pole Description Standard Wood F # # Installed Removed 5 (b) Installation and/or removal of FPL-owned additional lighting facilities where a cost estimate for these facilities will be determined based on the job scope, and the Additional Lighting Charges factor applied to determine the monthly rate. (c) Modification to existing facilities other than described above or additional notes (explain fully): (Continue on Sheet No. 9.142) Issued by: Tiffany Cohen, Senior Director, Regulatory Rates, Cost of Service and Systems Effective: January 1, 2022 Second Revised Sheet No. 9.142 FLORIDA POWER & LIGHT COMPANY Cancels First Sheet No. 9.142 (Continue from Sheet No. 9.141) That, for and in consideration of the covenants set forth herein, the parties hereto covenant and agree as follows: FPL AGREES: 1. To install or modify the lighting facilities described and identified above (hereinafter called the Lighting System), fumish to the Customer the electric energy necessary for the operation of the Lighting System, and fumish such other services as are specified in this Agreement, all in accordance with the terms of FPL's currently effective lighting rate schedule on file at the Florida Public Service Commission (FPSC) or any successive lighting rate schedule approved by the FPSC. THE CUSTOMER AGREES: . 2. To pay a monthly fee for fixtures and poles in accordance to the Lighting tariff, and additional lighting charge in the amount of $ C7_U These charges may be adjusted subject to review and approval by the FPSC. 3. To pay Contribution in Aid of Construction (CIAC) in the amount of $ O' 00 prior to FPL's initiating the requested installation or modification. 4. To pay the monthly maintenance and energy charges in accordance to the Lighting tariff. These charges may be adjusted subject to review and approval by the FPSC. 5. To purchase from FPL all the electric energy used for the operation of the Lighting System. 6. To be responsible for paying, when due, all bills rendered by FPL pursuant to FPL's currently effective lighting rate schedule on file at the FPSC or any successive lighting rate schedule approved by the FPSC, for facilities and service provided in accordance with this agreement. 7. To provide access, suitable construction drawings showing the location of existing and proposed structures, and appropriate plats necessary for planning the design and completing the construction of FPL facilities associated with the Lighting System. 8. To have sole responsibility to ensure lighting, poles, luminaires and fixtures are in compliance with any applicable municipal or county ordinances goveming the size, wattage, lumens or general aesthetics. 9. For new FPL-owned lighting systems, to provide final grading to specifications, perform any clearing if needed, compacting, removal of stumps or other obstructions that conflict with construction, identification of all non-FPL underground facilities within or near pole or trench locations, drainage of rights -of -way or good and sufficient easements required by FPL to accommodate the lighting facilities. 10. For FPL-owned fixtures on customer -owned systems: a. To perform repairs or correct code violations on their existing lighting infrastructure. Notification to FPL is required once site is ready. b. To repair or replace their electrical infrastructure in order to provide service to the Lighting System for daily operations or in a catastrophic event. c. In the event the light is not operating correctly, Customer agrees to check voltage at the service point feeding the lighting circuit prior to submitting the request for FPL to repair the fixture. IT IS MUTUALLY AGREED THAT: 11. Modifications to the facilities provided by FPL under this agreement, other than for maintenance, may only be made through the execution of an additional lighting agreement delineating the modifications to be accomplished. Modification of FPL lighting facilities is defined as the following: a. the addition of lighting facilities: b. the removal of lighting facilities; and c. the removal of lighting facilities and the replacement of such facilities with new facilities and/or additional facilities. Modifications will be subject to the costs identified in FPL's currently effective lighting rate schedule on file at the FPSC, or any sucr.Pssive schedule approved by the FPSC. (Continue on Sheet No. 9.143) Issued by: Tiffany Cohen, Senior Director, Regulatory Rates, Cost of Service and Systems Effective: January 1, 2022 Second Revised Sheet No. 9.143 FLORIDA POWER & LIGHT COMPANY Cancels First Revised Sheet No. 9.143 (Continue on Sheet No. 9.142) 12. FPL will, at the request of the Customer, relocate the lighting facilities covered by this agreement, if provided sufficient rights -of -way or easements to do so and locations requested are consistent with clear zone right-of-way setback requirements. The Customer shall be responsible for the payment of all costs associated with any such Customer- requested relocation of FPL lighting facilities. Payment shall be made by the Customer in advance of any relocation. Lighting facilities will only be installed in locations that meet all applicable dear zone right-of-way setback requirements. 13. FPL may, at any time, substitute for any fixture installed hereunder another equivalent fixture which shall be of similar illuminating capacity and efficiency. 14. This Agreement shall be for a term of ten (10) years from the date of initiation of service, and, except as provided below, shall extend thereafter for further successive periods of five (5) years from the expiration of the initial ten (10) year term or from the expiration of any extension thereof. The date of initiation of service shall be defined as the date the first lights are energized and billing begins, not the date of this Agreement. This Agreement shall be extended automatically beyond the initial the (10) year term or any extension thereof, unless either party shall have given written notice to the other of its desire to terminate this Agreement. The written notice shall be by certified mail and shall be given not less than ninety (90) days before the expiration of the initial ten (10) year term, or any extension thereof. 15. In the event lighting facilities covered by this agreement are removed, either at the request of the Customer or through termination or breach of this Agreement, the Customer shall be responsible for paying to FPL an amount equal to the original installed cost of the facilities provided by FPL under this agreement less any salvage value and any depreciation (based on current depreciation rates approved by the FPSC) plus removal cost. 16. Should the Customer fail to pay any bills due and rendered pursuant to this agreement or otherwise fail to perform the obligations contained in this Agreement, said obligations being material and going to the essence of this Agreement, FPL may cease to supply electric energy or service until the Customer has paid the bills due and rendered or has fully cured such other breach of this Agreement. Any failure of FPL to exercise its rights hereunder shall not be a waiver of its rights. It is understood, however, that such discontinuance of the supplying of electric energy or service shall not constitute a breach of this Agreement by FPL, nor shall it relieve the Customer of the obligation to perform any of the terms and conditions of this Agreement. 17 The obligation to furnish or purchase service shall be excused at any time that either party is prevented from complying with this Agreement by strikes, lockouts, fires, riots, acts of God, the public enemy, or by cause or causes not under the control of the party thus prevented from compliance, and FPL shall not have the obligation to furnish service if it is prevented from complying with this Agreement by reason of any partial, temporary or entire shut -down of service which, in the sole opinion of FPL, is reasonably necessary for the purpose of repairing or making more efficient all or any part of its generating or other electrical equipment. 18. This Agreement supersedes all previous Agreements or representations, either written, oral, or otherwise between the Customer and FPL, with respect to the facilities referenced herein and constitutes the entire Agreement between the parties. This Agreement does not create any rights or provide any remedies to third parties or create any additional duty, obligation or undertakings by FPL to third parties. 19. In the event of the sale of the real property upon which the facilities are installed, upon the written consent of FPL, this Agreement may be assigned by the Customer to the Purchaser. No assignment shall relieve the Customer from its obligations hereunder until such obligations have been assumed by the assignee and agreed to by FPL. 20. This Agreement shall inure to the benefit of and be binding upon the successors and assigns of the Customer and FPL. 21. The lighting facilities shall remain the property of FPL in perpetuity. 22. This Agreement is subject to FPL's Electric Tariff, including, but not limited to, the General Rules and Regulations for Electric Service and the Rules of the FPSC, as they are now written, or as they may be hereafter revised, amended or supplemented. In the event of any conflict between the terms of this Agreement and the provisions of the FPL Electric Tariff or the FPSC Rules, the provisions of the Electric Tariff and FPSC Rules shall control, as they are now written, or as they may be hereafter revised, amended or supplemented. (Continue on Sheet No. 9.144) Issued by: Tiffany Cohen, Director, Rates and Tariffs Effective: January 1, 2022 FLORIDA POWER & LIGHT COMPANY First Revised Sheet No. 9.144 Cancels Original Sheet No. 9.144 IN WITNESS WHEREOF, the parties hereby caused this Agreement to be executed in triplicate by their duly authorized representatives to be effective as of the day and year first written above. Changes and Terms Accepted: City of Crestview Customer (Print or type name oization) By: Si uthorized ' +resentative JB Whitten (Print or type name) Title: Mayor FLORIDA POWER & LIGHT COMPANY By: (Signature) Brian White Dpigeta: 2022 n052915292 h05'00' Brian White (Print or type name) Title: Sales Manager Issued by: Tiffany Cohen, Director, Rates and Tariffs Effective: March 3, 2020 INDEX OF LIGHTING PLANS SHEET NO. SHEET DESCRIPTION L-1 L-2 L-3 L-4 L-5 - L-8 JuanRrye/a KEY SHEET GENERAL NOTES LIGHTING DATA TABLE LIGHTING LEGEND LIGHTING PLAN S TA TE OF FLORIDA DEPARTMENT OF TRANS /' OIRTA T IONr CONTRACT PLANS FINANCIAL PROJECT ID 443659-1-58-01 OKALOOSA COUNTY (57060) STATE ROAD NO. 85 (N. FERDON BLVD) FROM SR 10 (US 90) TO N. OF COMMERCE DR. LIGHTING PLANS 919,204 1:78:59 PM Derau7t LOCATION OF PROJECT hops://9oo91/maps/VShj7gONpTTU67yg6 THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY: Erez Digitally signed by Erez Dayan:A0141000000 DayanN01410C00000177F 0177F9452C2A00017 9452C2A00017668 Date: 2021.09.09 15:07:46 668-04'00' ON THE DATE ADJACENT TO THE SEAL PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED. THE SIGNATURE MUST BE VERIFIED IN THE ELECTRONIC DOCUMENTS. LIGHTING PLANS ENGINEER OF RECORD: EREZ DAYAN, P.E. P.E. NO.: 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 407-775-2209 CONTRACT NO.: CA818 VENDOR NO.: 833811146-01 FDOT PROJECT MANAGER: JOHN WHITTINGTON, P.E. (850) 330-1425 CONSTRUCTION CONTRACT NO. FISCAL YEAR SHEET NO. E3U84 22 L-1 P.\POEIY_G oup 20-19\40365915201_51. IS \righttm \41"E1 SLT'fait DATE luanerve/h DESCRIPTION REVISIONS I DATF GENERAL NOTES 1. ALL LIGHT POLE INSTALLATIONS AND RETROFITS ARE TO BE DONE BY GULF POWER OR THEIR ASSIGNED CONTRACTOR. THESE PLANS HAVE BEEN PREPARED FOR UTILITY COORDINATION ONLY. 2. UTILITY/AGENCY OWNERS: COMPANY AT&T FLORIDA (DISTRIBUTION) AUBURN WATER SYSTEM CENTURYLINK CITY OF CRESTVIEW COX COMMUNICATIONS GULF POWER COMPANY (DISTRIBUTION) OKALOOSA COUNTY INFORMATION TECHNOLOGY OKALOOSA COUNTY SIGNAL SYSTEM OKALOOSA GAS DISTRICT UNIT! FIBER DESCRIPTION CONTACT TIM EDGAR DOUG SIMS AMBER GILSON WAYNE STEELE TIMOTHY HUTZENBUEHLER JEREMY COON JASON SNYDER RANDY SHOWERS RYAN BURNS KYLE HILL PHONE (850) 293 3780 (850) 682-3413 ext. 114 (850) 815-3131 (850) 682-6132 ext. 102 (850) 314-8143 (850) 689-4629 (850) 651-7570 (850) 609-6181 (850) 280-4851 (850) 544-1400 LIGHTING DESIGN CRITERIA - MIDBLOCK CROSSWALK LOW AMBIENT LUMINANCE - 2.3 AVERAGE VERTICAL FOOT-CANDLES -WIND SPEED - 140 MPH LIGHTING DESIGN CRITERIA - SIGNALIZED INTERSECTION RETROFIT HORIZONTAL LIGHTING - 1.5 HORIZONTAL FOOT-CANDLES (STANDARD) - 1.0 HORIZONTAL FOOT-CANDLES (MINIMUM) - ILLUMINATION UNIFORMITY RATIOS AVG./MIN. = 4.1 OR LESS MAX./MIN. = 10:1 OR LESS - WIND SPEED - 140 MPH VERTICAL LIGHTING - 1.5 VERTICAL FOOT-CANDLES (STANDARD) - 1.0 VERTICAL FOOT-CANDLES (MINIMUM) - WIND SPEED - 140 MPH EREZ DAY AN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 WI l i071 1:%8:5,4 P7f Lel ault S TATE OF FLORIDA DEPARTMENT OF TRANSPORTATION ROAD NO. SR 85 COUNTY OKALOOSA 1FINANCIAL PROJECT ID 443659-1-58-01 GENERAL NOTES SHEET NO. L-2 P;\PR01Z Group 20-19\4436591i207_SR 85vign[in4\60Al LrlL9 LIGHTING DATA TABLE POLE BASELINE STATION POLE SIDE MOUNTING LUMINAIRE ARM ARM I NUMBER OF 1 FIXTURE NOTES NO. OFFSET HEIGHT WATTAGE LENGTH CONFIGURATION LUMINAIRES 1 SR 85 2 SR 85 3 SR 85 4 SR 85 5 SR 85 6 SR 85 7 SR 85 8 SR 85 9 SR 85 10 SR 85 11 SR 85 12 SR 85 13 SR 85 14 SR 85 15 SR 85 16 SR 85 17 SR 85 18 SR 85 DATF luanRrver 919I2023 1:23:34 PM Putout( 48+93 EXISTING LT EXISTING EXISTING EXISTING SINGLE BRACKET 1 EXISTING TO REMAIN EXISTING UTILITY POLE WITH BRACKET & LED LUMINAIRE. TO REMAIN. 49+08 EXISTING RT 30' 204 10' SINGLE BRACKET 1 ATB2_60BLED1O_XXXXX_R3_4K_SK EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET AND LUMINAIRE. 49+92 EXISTING RT 27' 268 10' SINGLE BRACKET 1 ATB2_80BLED1O_XXXXX_R3_4K_5K EXISTING UTILITY POLE WITH BRACKET & LUMINAIRE EXISTING BRACKET & LUMINAIRE TO BE REPLACED. 63+38 EXISTING LT 35' 204 10' SINGLE BRACKET I 1 ATB2_60BLED]0_XXXXX_R3_4K_SK EXISTING POLE WITH BRACKET & LUMINAIRE. EXISTING BRACKET & LUMINAIRE TO BE REPLACED. 63+80 53.8' LT 30' 204 10' SINGLE BRACKET 1 ATB2_60BLED1O_XXXXX_R3_4K_SK PROPOSED NEW POLE. POLE TO BE PLACED ON 8TH AVE 64+64 65+57 120+33 121+15 121+26 121+45 121+48 132+11 132+43 133+22 133+59 133+79 EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING 112.1' EXISTING 115.5' 56.6' RT 30' EXISTING I RT 30' 268 10' SINGLE BRACKET 1 ATB2_80BLED1O_XXXXX_R3_4K_5K EXISTING UTILITY POLE WITH BRACKET & LUMINAIRE EXISTING BRACKET & LUMINAIRE TO BE REPLACED. EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RT 30' 204 10' SINGLE BRACKET 1 ATB2_60BLED1O_XXXXX_R3_4K_SK RETROFIT WITH NEW BRACKET AND LUMINAIRE. POLE ON SITWELL BLVD. LT 30' 204 10' SINGLE BRACKET 1 ATB2 606LED70 XXXXX R3 4K SK EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET AND LUMINAIRE. EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING LT 30' 268 10' SINGLE BRACKET 1 ATB2_80BLEDIO_XXXXX_R3_4K_5K RETROFIT WITH NEW BRACKET AND LUMINAIRE. POLE ON GARDEN ST. RT 30' 204 10' DUAL BRACKETS 2 LT LT 30' 204 10' SINGLE BRACKET LT 30' 204 10' SINGLE BRACKET RT 30' 204 10' DUAL BRACKETS LT I 30' 204 I 10' SINGLE BRACKET 204 10' SINGLE BRACKET 111.9' LT 30' 204 10' SINGLE BRACKET 134+57 DESCRIPTION EXISTING RT EXISTINGI EXISTING EXISTINGI DUAL BRACKETS REVISIONS DATE DESCRIPTION EREZ DAYAN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 ATB2_60BLED10 XXXXX R3 4K 5K & EXISTING TO REMAIN 1 ATB2_60BLED1O_XXXXX_R3_4K_SK 1 ATB2_60BLED1O_XXXXX_R3_4K_SK 2 ATB2_60BLEDIO XXXXX R3 4K_5K & EXISTING TO REMAIN 1 ATB2_60BLED1O_XXXXX_R3_4K_5K 1 ATB2_60BLED1O_XXXXX_R3_4K_SK 1 ATB2_60BLED1O_XXXXX_R3_4K_SK 2 EXISTING TO REMAIN STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION ROAD NO. I COUNTY SR 85 OKALOOSA FINANCIAL PROJECT ID 443659-1-58-01 EXISTING UTILITY POLE WITH DUAL BRACKETS AND LUMINAIRES. REPLACE BRACKET AND LUMINAIRE FACING TOWARDS SR 85. OTHER BRACKET AND LUMINAIRE TO REMAIN. EXISTING POLE WITH BRACKET & LUMINAIRE. REMOVE EXISTING BRACKET & LUMINAIRE. POLE TO REMAIN. EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET AND LUMINAIRE. PROPOSED NEW POLE. EXISTING UTILITY POLE WITH DUAL BRACKETS AND LUMINAIRES. REPLACE BRACKET AND LUMINAIRE FACING TOWARDS SR 85. OTHER BRACKET AND LUMINAIRE TO REMAIN. PROPOSED NEW POLE. PROPOSED NEW POLE. PROPOSED NEW POLE. EXISTING UTILITY POLE WITH DUAL BRACKETS AND LUMINAIRES. TO REMAIN. LIGHTING DATA TABLE SHEET NO. L-3 P:\P00i2 Group Y4,-0,14436690JlI_5N E3\ngMal.,YW' LJ OLrl EXISTING UTILITY POLE WITH SINGLE BRACKET AND LUMINAIRE. REMOVE EXISTING ARM AND LUMINAIRE. POLE TO REMAIN. INSTALL NEW BRACKET WITH NEW LED LUMINAIRE. NEW BRACKET AND LED LUMINAIRE TO BE INSTALLED ON EXISTING UTILITY POLE EXISTING POLE WITH DUAL BRACKETS AND LUMINAIRES. REPLACE ONE BRACKET AND LUMINAIRE. OTHER BRACKET AND LUMINAIRE TO REMAIN. nccrarprrnN REVISIONS narE LEGEND PROPOSED NEW POLE WITH NEW BRACKET AND LED LUMINAIRE. EXISTING POLE WITH SINGLE BRACKET AND LUMINAIRE. REMOVE EXISTING ARM AND LUMINAIRE. POLE TO REMAIN. DESCRIPTION —I EREZ DAYAN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 9/ 12021 1.28:l PM Ae*autt STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION EXISTING POLE WITH SINGLE BRACKET AND LUMINAIRE TO REMAIN. EXISTING POLE WITH DUAL BRACKETS AND LUMINAIRES TO REMAIN. ROAD NO. COUNTY FINANCIAL PROJECT ID SR 85 OKALOOSA 443659-1-58-01 LIGHTING LEGEND SHEET NO. L-4 P:V'0012 Group 20-19\44345Y1f0OJ SR RS\Rgnl9n9 \PLOrLTo1.4' W(D} y- ^wl0}-- DATE JuanRlverA DESCRIPTION POLE NO. I ' EXISTING UTILITY POLE WITH BRACKET & LUMINAIR TO REMAIN STA. 48+93 -WFQL.._ _:__...-_-.O.T.-wtD1_L fj POLE NO. 2 EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET & LUMINAIRE MOUNTING HEIGHT: 30' STA. 49+0B SR 85 (N. FERDON BLVD.) _ __-_ ^-:WI8YOOE REVISIONS 49 $ SURVEY SR 85 POLE NO. 3 EXISTING UTILITY POLE WITH BRACKET & LUMINAIRE REPLACE EXISTING BRACKET & LUMINAIRE MOUNTING HEIGHT: 27' STA. 49+92 DESCRIPTION \ R/W LINE SR 85 [IV. FERD_O_IV BLVD.J \ _ 51 0 10 40 Feet \ \ i= _�.. .. � __- R/W LINE SR 85 ROADWAY ID 57060000, MP. 0.570 UNSIGNALIZED INTERSECTION OF SR 85 WITH LONG DR. D/i2021 1:78:55 PM Default EREZ DAYAN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 \ STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION ROAD NO. SR 85 COUNTY 1 FINANCIAL PROJECT ID OKALOOSA 1 443659-1-58-01 LIGHTING PLAN SHEET NO. L-5 P..V'0017 Group 2'1(nreje55 0[Ol I9 &G\F 9 t n kPLANLI0I.1✓; DATE IuanHrverd R/W LINE I POLE 4 EXISTING UTILITY POLE WITH BRACKET & LUMINAIRE REPLACE EXISTING BRACKET & LUMINAIRE MOUNTING HEIGHT: 35' STA. 63+38 POLE NO. 5 PROPOSED NEW POLE MOUNTING HEIGHT: 30' STA. 63+80 53.8' LT or —5wiP} 63 OE?t1Fl3L-=== OE+ =6FOC E OF •1!✓- =i- 0 OF CRIPTJON R/W LINE REVISIONS Dart POLE NO. 6 EXISTING UTILITY POLE WITH BRACKET & LUMINAIRE REPLACE EXISTING BRACKET & LUMINAIRE MOUNTING HEIGHT: 30' STA. 64+64 DESCRIPTION R/W LINE (ok - - -WIDE - -W(D} OT of I 65 @ SURVEY 5R 85 SR 85 - -SID). 6¢ 0 10 40 Feet -- —W(DF- - • - - _ -WNW -' of = ort SR 85 N._FERDON BLVD.) IJ POLE Nn. 7 In EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING \ \ RETROFIT WITH NEW BRACKET & LUMINAIRE \ - MOUNTING HEIGHT: 30' m \ STA. 65+57 q r \ \ r2O 67 5I v 0U=V�'f `— : �For(n,__ ROADWAY ID 57060000, MP. 0.850 SIGNALIZED INTERSECTION OF SR 85 WITH 8TH AVE./SITVW(ELL BLVD. EREZ DAYAN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 9/4/7011 1:18:56 /M Der aWt STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION ROAD NO. COUNTY FINANCIAL PROJECT ID SR 85 OKALOOSA 443659-1-58-01 LIGHTING PLAN SHEET NO. L-6 : ,PWII_0,oup 20-19\14.1659I589J 511 6%\IISNORJ\PLANCTDI,0; POLE NO. 8 EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET & LUMINAIRE MOUNTING HEIGHT: 30' STA. 120+33 DIV - - - - `N11117 R/W LINE 8 ?.. 119 3, . DATE I SR 85 (N. FERDON BLVDJ ni. OTV - E POLE NO. 9 EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET & LUMINAIRE cr../ MOUNTING HEIGHT: 30' STA. 121+15 1 POLE NO. ] EXISTING F LE WITH BRACKET & LUMINAIRE REMOVE EXISTING BRACKET & LUMINAIRE POLE TO REMAIN STA. 121+45 — — - -5(0)- 0 10 40 =M Feet /--R/W LINE ;(0)- 5(D POLE NO. 12 EXISTING UTILITY POLE WITH NO ROADWAY LIGHTING RETROFIT WITH NEW BRACKET & LUMINAIRE MOUNTING HEIGHT: 30' STA. 121+48 - 0E - .. OE.._�.. O`V OE::. -----. ory -W(D)- - - - - --_— __--- _-- _— SR 85 (N. FERDON BLVD.L 0E- 120 T 121 123 _ — L' � ` I BFOC(D) BFOO(D) BFOC(D) 6 SURVEY SR 85 ' 111 • BFOC(D) BFOC QffOC-------_._.-ODti-OE-OFOFQ OTV0&--0.@OC------0580-----OF0G---00E OF0t. ----OFOG 0&1-F LIT -W(D)- - - - - - - - - -VJ(D} - - - . W W(D} 9F5(R/PT1ON REVISIONS DATE UW(D). W(D)- - - - -(g)AA R/W LINE DESCRIFT INDUSTRIAL DR. §FEE11)AFt4gfr4J - , BFOC(D) BFOC(D) BFOC(D) -• qu41 ei , OE POLE N0. 10 EXISTING UTILITY POLE WITH DUAL BRACKETS AND LUMINAIRES REPLACE EXISTING BRACKET & LUMINAIRE FACING TOWARDS SR 85 MOUNTING HEIGHT: 30' BRACKET AND LUMINAIRE FACING INDUSTRIAL DR. TO REMAIN STA. 121+26 SR 85 ROADWAY ID 57060000, MP. 1.914 SIGNALIZED INTERSECTION OF SR 85 WITH GARDEN ST. EREZ DAYAN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 zuann,vera 9/9/3G2t 1:221:51 PN Delau+t BFOC(D) • 'IMP* STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION LIGHTING 7�'/� �y ROAD NO. Ij COUNTY FINANCIAL PROJECT ID Lu �y���L G y-��� SR 85 I OKALOOSA 443659-1-58-01 L-7 Y:-S0111l&roup 20-11i1F3ES915i'Pf SX 'BSV,gnt,ni\PLANi2Di.u_ SHEET NO. 30 POLE NO. 13 PROPOSED NEW POLE MOUNTING HEIGHT: 30' STA. 132+11 112.1' LT -W(D} - • - -W(D)- -W(D} 131 132 SR B5 (i..,FERDON BLVD.) `8E[B1:--1 Via) :fif •- oE€e w - i 1.1 1)- - : 3a)M ::.-- _--BF6e1731- - ° - ° - ; O \L-R/W LINE POLE N0. 14 EXISTING UTILITY POLE WITH DUAL BRACKETS AND LUMINAIRES REPLACE BRACKET AND LUMINAIRE FACING TOWARDS SR 85 MOUNTING HEIGHT: 30' BRACKET AND LUMINAIRE FACING INDUSTRIAL DR. TO REMAIN STA. 132+43 INDUSTRIAL DR. REVISIONS DATE I DESCRIPTION D4TF JuanRtvera DESCRIPTION W(D} POLE NO. 15 PROPOSED NEW POLE MOUNTING HEIGHT: 30' STA. 133+22 115.5' LT (, - W(D)- 133 @ SURVEY SR 85 0 5 r R/W LINE POLE N0. 17 PROPOSED NEW POLE MOUNTING HEIGHT: 30' STA. 133+79 111.9' LT SR 85 (N. FE�1RDON BLVD.)__> 134 BFOC(D11M pp((FFPOFOC PROPOSED NEW POLE MOUNTING HEIGHT: 30' STA. 133+59 56.6' RT SR 85 ROADWAY ID 57060000, MP. 2.077 SIGNALIZED INTERSECTION OF SR 85 WITH COMMERCE DR. EREZ DAYAN, P.E. P.E. LICENSE NUMBER 62144 AVANT ENGINEERING GROUP, LLC 1300 MINNESOTA AVENUE, SUITE 201 WINTER PARK, FL 32789 9/s/ta,41 1:21158 • Pal Deeault INDU5TR1A1. OR. 135 R/W LINE 0 10 40 Feet FO PD) arca-wi POLE N0. 18 EXISTING UTILITY POLE WITH DUAL BRACKETS & LUMINAIRES TO REMAIN STA. 134+57 STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION ROAD NO. I COUNTY I FINANCIAL PROJECT ID 5R 85 OKALOOSA 443659-1-58-01 LIGHTING PLAN SHEET NO. L-8 .'.\Pp0I2 Group t0-I9\44sy5916161_5R NSVIgat,o,aP1.WLT01.d Project Monthly Cost Breakdown a Crestview Project: 443659-1-58-01 Monthly Fixture Cost: $ 255.89 Monthly Pole Cost: $ 27.50 ALC: $8.83 Total Monthly: Fixture Count: Monthly Cost Per Fixture: FDOT Reimbursement per fixture/month: $ $ 292.22 15.00 $ 19.48 $ 22.00 Monthly *FP&L Billing will be set up on a separate account for this project and will bill after all lighting has been installed and FDOT inspection has been completed. Bill to City of Crestview will be $292.22 per month FDOT to reimburse city approx $337.00 per month on an annual basis