HomeMy Public PortalAboutRE_ Town of Gulf Stream - Phase #1 - Issues - Rescope - T-11 Renee Basel From:John Zoerhof <jzoerhof@HYPOWERINC.COM> Sent:Monday, August 11, 2014 11:13 AM To:Lehr, John; Danny Brannon Cc:Cliff Spitzer; Owen, Jay D Subject:RE: Town of Gulf Stream - Phase #1 - Issues - Rescope - T-11 John, First part is as expected. I am having trouble discerning location 15.8 and the purpose in the second part? , Regards John Zoerhof Division Manager – Power Services Direct 954.917.1439 Cell 954.448.0369 954.978.9300 – Main 954.978.8666. - Fax Please consider the environment before printing this e-mail  NOTICE: This email is intended solely for the use of the individual to whom it is addressed and may contain information that is privileged, confidential or otherwise exempt from disclosure. If the reader of this email is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify us by telephone and return the original message to us at the listed email address. Thank You. From: Lehr, John \[mailto:John.Lehr@fpl.com\] Sent: Monday, August 11, 2014 11:06 AM To: John Zoerhof; Danny Brannon Cc: Cliff Spitzer; Owen, Jay D Subject: Town of Gulf Stream - Phase #1 - Issues - Rescope - T-11 Danny, John, FYI ………………… Please see the attached. The proposed scope change, eliminate T-11 C50KVA, will work; however, the following will be required:  Install 1-3-750A sec in 1-5” PVC (1-6” HDPE) Loc 16 to Loc 13.5 & Install 1 48” HH @ Loc 13.5  Install 1-4/0A TPX sec in 1-2” PVC (1-2” HPDE) Loc 16 to Loc 15.8 (HH)(2-runs of 1-4/0A TPX required) 1 If you agree to the scope change/ installation, I will process the change request for the prints. Thanks! John C. Lehr, Jr. Project Manager FPL (561)-845-4624 From: John Zoerhof \[mailto:jzoerhof@HYPOWERINC.COM\] Sent: Monday, August 11, 2014 10:12 AM To: Danny Brannon Cc: Lehr, John; Cliff Spitzer Subject: RE: Town of Gulf Stream - Phase #1 - Issues Importance: High Good morning, We have limited availability of bore crews to finish up all the remaining conduits by tomorrow. Do we have an answer on the Service to Jamaica? TX 11 & 12 (Where the guy issue was) , Regards John Zoerhof Division Manager – Power Services Direct 954.917.1439 Cell 954.448.0369 954.978.9300 – Main 954.978.8666. - Fax Please consider the environment before printing this e-mail  NOTICE: This email is intended solely for the use of the individual to whom it is addressed and may contain information that is privileged, confidential or otherwise exempt from disclosure. If the reader of this email is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify us by telephone and return the original message to us at the listed email address. Thank You. From: John Zoerhof Sent: Wednesday, August 06, 2014 12:30 PM To: Danny Brannon 2 Cc: John Lehr Subject: Re: Town of Gulf Stream - Phase #1 - Issues True. I am just trying to provide a possible solution. Sent from my Verizon Wireless 4G LTE Smartphone ----- Reply message ----- From: "Danny Brannon" <DBrannon@BnGEngineers.com> To: "John Zoerhof" <jzoerhof@HYPOWERINC.COM> Cc: "'Lehr, John'" <John.Lehr@fpl.com> Subject: Town of Gulf Stream - Phase #1 - Issues Date: Wed, Aug 6, 2014 11:38 AM As you only have enough pipe for the primary to be looped, you would have to bore again. Danny P. Brannon, P.E. Brannon & Gillespie, LLC Consulting Engineers 631 US Highway One, Suite 301 North Palm Beach, Florida 33408 Off: (561) 847-4435 Cell: (561) 307-9454 Website: www.BnGEngineers..com From: John Zoerhof \[mailto:jzoerhof@HYPOWERINC.COM\] Sent: Wednesday, August 06, 2014 8:39 AM To: Lehr, John Cc: Cliff Spitzer; Wayne Wilson - JHV (wwilson@jordanhighvoltage.com); Danny Brannon (DBrannon@BnGEngineers.com); Coyle, Kevin J; Owen, Jay D Subject: RE: Town of Gulf Stream - Phase #1 - Issues Responses in Blue The guys and anchors at TX 11 It sounded like the issue here was only scheduling. If that is the case, can we get the blessing to remove the guys ourselves? If scheduling is the issue, then what’s the WR so I can have someone investigate the crew? I stand corrected as Cliff was told a WR was required, then scheduling would be the issue. I took that to mean removal was acceptable. It seems to me this is not a Hypower issue as we would not request a WR. Note, if a guy exist today, then a guy needs to remain until the OH is removed. If that is the case then we have a “Chicken and Egg” conundrum given the location of the easement. Not sure what we can do without a directive solution from FPL. Moving them back to the east would impact the property vegetation, etc… Just a thought, can this service @ 111 Ocean be fed off of T-12 (100KVA) presently feeding the homes across the street? Eliminating TX-11 (50KVA)? Both C phase. Then we would just need a secondary HH there. Top Side Jumpers 3 On the Feeder/Primary Risers on each ends. Were these in the OH contract? We really need to heat this up ASAP. I’m working w/ the local area to have someone install the jumpers & awaiting a call back. Thanks , Regards John Zoerhof Division Manager – Power Services Direct 954.917.1439 Cell 954.448.0369 954.978.9300 – Main 954.978.8666. - Fax Please consider the environment before printing this e-mail  NOTICE: This email is intended solely for the use of the individual to whom it is addressed and may contain information that is privileged, confidential or otherwise exempt from disclosure. If the reader of this email is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify us by telephone and return the original message to us at the listed email address. Thank You. From: Lehr, John \[mailto:John.Lehr@fpl.com\] Sent: Tuesday, August 05, 2014 4:34 PM To: John Zoerhof Cc: Cliff Spitzer; Wayne Wilson - JHV (wwilson@jordanhighvoltage.com); Danny Brannon (DBrannon@BnGEngineers.com); Coyle, Kevin J; Owen, Jay D Subject: Town of Gulf Stream - Phase #1 - Issues John, FYI ………………. See my response below in RED. Thanks! John C. Lehr, Jr. Project Manager FPL (561)-845-4624 From: John Zoerhof \[mailto:jzoerhof@HYPOWERINC.COM\] Sent: Tuesday, August 05, 2014 9:01 AM To: Lehr, John; Danny Brannon (DBrannon@BnGEngineers.com) Cc: Cliff Spitzer; Wayne Wilson - JHV (wwilson@jordanhighvoltage.com) Subject: Issues Importance: High 4 Good morning, As we hurry to the finish line we need to clarify a couple things. 1.The guys and anchors at TX 11 2.It sounded like the issue here was only scheduling. If that is the case, can we get the blessing to remove the guys ourselves? If scheduling is the issue, then what’s the WR so I can have someone investigate the crew? Note, if a guy exist today, then a guy needs to remain until the OH is removed. 3.Top Side Jumpers a.On the Feeder/Primary Risers on each ends. Were these in the OH contract? We really need to heat this up ASAP. I’m working w/ the local area to have someone install the jumpers & awaiting a call back. , Regards John Zoerhof Division Manager – Power Services Direct 954.917.1439 Cell 954.448.0369 954.978.9300 – Main 954.978.8666. - Fax Please consider the environment before printing this e-mail  NOTICE: This email is intended solely for the use of the individual to whom it is addressed and may contain information that is privileged, confidential or otherwise exempt from disclosure. If the reader of this email is not the intended recipient or the employee or agent responsible for delivering the message to the intended recipient, you are hereby notified that any dissemination, distribution, or copying of this communication is strictly prohibited. If you have received this communication in error, please immediately notify us by telephone and return the original message to us at the listed email address. Thank You. This email is free from viruses and malware because avast! Antivirus protection is active. To help prot ect your priva cy, 5