HomeMy Public PortalAboutRE_ Town of Gulf Stream - IMAG0680_jpg (2) Renee Basel From:John Zoerhof <jzoerhof@HYPOWERINC.COM> Sent:Wednesday, March 19, 2014 10:56 AM To:Danny Brannon; 'Lehr, John' Cc:Cliff Spitzer; 'Owen, Jay D' Subject:RE: Town of Gulf Stream - IMAG0680.jpg I am looking into why they used 2 pads when there are supposed to be single duplex pads in the yard. Thanks, John Zoerhof Division Manager - Power Services -----Original Message----- From: Danny Brannon \[mailto:DBrannon@BnGEngineers.com\] Sent: Wednesday, March 19, 2014 10:53 AM To: 'Lehr, John' Cc: Cliff Spitzer; John Zoerhof; 'Owen, Jay D' Subject: RE: Town of Gulf Stream - IMAG0680.jpg Two pads require a space of 54" x 96", while one 3phase pad requires 60" x 80". So, for space, one is better. I will look into what they are doing. We have some locations along Hidden Harbor road that would benefit from the reduced depth. Is JD the Contract Rep on this job? Danny P. Brannon, P.E. Brannon & Gillespie, LLC Consulting Engineers 631 US Highway One, Suite 301 North Palm Beach, Florida 33408 Off: (561) 847-4435 Cell: (561) 307-9454 Website: www.BnGEngineers.com -----Original Message----- From: Lehr, John \[mailto:John.Lehr@fpl.com\] Sent: Wednesday, March 19, 2014 10:48 AM To: Danny Brannon Cc: 'Cliff Spitzer'; 'John Zoerhof'; Owen, Jay D Subject: Town of Gulf Stream - IMAG0680.jpg Danny, FYI .................. The job was MECA'd & issued 11 Duplex pads, but if the installation is tight, as in the past, the 2-pad configuration can work. And, no, no shortage of concrete pads. 1 John C. Lehr, Jr. Project Manager FPL (561)-845-4624 -----Original Message----- From: Danny Brannon \[mailto:DBrannon@BnGEngineers.com\] Sent: Wednesday, March 19, 2014 9:28 AM To: 'John Zoerhof' Cc: Lehr, John; 'Cliff Spitzer' Subject: RE: IMAG0680.jpg Do you look at the FPL Distribution Construction Standards. This setup is correct. Make sure the ground has been compacted and that pads are level. Make sure the leading phase is going into the lighting transformer. John, Did you approve the contractor using two single phase pads versus the three phase pad for open delta banks? Does FPL have a material shortage problem? Danny P. Brannon, P.E. Brannon & Gillespie, LLC Consulting Engineers 631 US Highway One, Suite 301 North Palm Beach, Florida 33408 Off: (561) 847-4435 Cell: (561) 307-9454 Website: www.BnGEngineers.com -----Original Message----- From: John Zoerhof \[mailto:jzoerhof@HYPOWERINC.COM\] Sent: Tuesday, March 18, 2014 4:06 PM To: Danny Brannon (DBrannon@BnGEngineers.com) Cc: Lehr, John; Cliff Spitzer Subject: FW: IMAG0680.jpg Before we get too far here, what is the set up with respect to the transformer locations? This looks to me like the low profile will be on the left. Is that correct? Thanks, John Zoerhof Division Manager - Power Services -----Original Message----- From: Cliff \[mailto:cliffspitzer@yahoo.com\] Sent: Tuesday, March 18, 2014 3:30 PM To: Cliff Spitzer; John Zoerhof Subject: IMAG0680.jpg 2 --- This email is free from viruses and malware because avast! Antivirus protection is active. http://www.avast.com --- This email is free from viruses and malware because avast! Antivirus protection is active. http://www.avast.com 3