Loading...
HomeMy Public PortalAboutPolk St_77U.S. DEPARTMENT OF HOMELAND SECURITY ELEVATION CERTIFICATE FEDERAL EMERGENCY MANAGEMENT AGENCY National Flood Insurance Program Important: Read the instructions on pages 1 -9. SECTION A - PROPERTY INFORMATION Al. Building Owner's Name J OMB Na. 1660 -0008 Expiration Date: July 31, 2015 FOR INSURANCE COMPANY USE Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. t Company NAIC Number. 77 POLK STREET I City TYBEE ISLAND State GA ZIP Code 31328 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 8 OF A RESUBDIVISION OF BLOCK 6, BAY WARD, TYBEE ISLAND A4. Building Use (e.g., Residential, Non- Residential, Addition, Accessory, etc.) RESIDENTIAL A5. Latitude /Longitude: Lat. N32"01'22.2" Long. W 80 °51'11.6" Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) 862 sq ft a) Square footage of attached garage N/A sq ft b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage or enclosure(s) within 1.0 foot above adjacent grade 6 within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b 1200 sq in c) Total net area of flood openings in A9.b NIA sq in d) Engineered flood openings? ® Yes ❑ No d) Engineered flood openings? ❑ Yes ® No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Communit y Number B2. County Name B3. State CITY OF TYBEE ISLAND 135164 CHATHAM I GEORGIA B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other /Source: B11. Indicate elevation datum used for BFE in Item 89: ❑ NGVD 1929 ® NAVD 1988 ❑ Other /Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction' ® Finished Construction "A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, AR/A1 -A30, AR/AH, AR/AO. Complete Items C2.a -h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: USGS TIDAL NO. 6 Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 ❑ Other /Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) 0 Lowest adjacent (finished) grade next to building (LAG) g) Highest adjacent (finished) grade next to building (HAG) h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 8.3 ® feet ❑ meters 17.6 ® feet ❑ meters 16.2 ® feet ❑ meters N /A. ❑ feet ❑ meters 17.5 ® feet ❑ meters 7.5 ® feet ❑ meters 8.1 ® feet ❑ meters 7.4 ® feet ❑ meters SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 US. Code, Section 1001. ® Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a ® Check here if attachments. licensed land surveyor? ® Yes ❑ No Certifier's Name JAMES M. KEATON, RLS License Number GA #2743 Title LAND SURVEYOR Company Name CHATHAM SURVEYING SERVICES, INC Address PO BOX 6164� City SAVANNAH State GA ZIP Code 31420 Signatyre " L�j/ .7i c Date OCTOBER 08, 2014 Telephone 912 - 303 -0302 5a�ORG/ n4��No.2743,- Su 02 \ \FS M. KEP� -EMA Form 086 -0-33 (7112) See reverse side for continuation. Replaces all previous editions. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 77 POLK STREET City TYBEE ISLAND State GA ZIP Code 31328 Company NAIC Number SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments C2a IS AN ENCLOSURE UNDER THE HABITABLE FLOOR THAT IS PART ENCLOSED WITH BLOCK WALLS AND PART WITH SHADOW- BOX FENCING. IT ALSO HAS A 35 s.f. ELEVATOR SHAFT. THERE IS OPEN SIDED PARKING AND STORAGE UNDER THE HABITABLE FLOOR. C2b IS THE HABITABLE FLOOR. C2e IS EXTERIOR HVAC EQUIPMENT ON A PLATFORM. C2h IS GRADE AT THE STEPS AT THE BACK RIGHT CORNER. ITEMS ABb & c ARE SMART VENTS THAT ALLOW FOR 200 s.f. EACH. THERE IS DUCT WORK UNDER THE FLOOR AT ELEVATION 15.0. Signature u� Date OCTOBER 08, 2014 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 —E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B, and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items B and/or 9 (see pages 8 -9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. /E4. Top of platform of machinery and /or equipment servicing the building is ❑feet ❑meters ❑above or . E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. SECTION G — COMMUNITY INFORMATION (OPTIONAL) -he local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G if this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G& -G10. In Puerto Rico only, enter meters. '1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) 32. ❑ A community official completed Section E for a building located in Zone A (without a FEMA- issued or community- issued BFE) or Zone AO. 31 ❑ The following information (Items G4 —G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate Of Compliance /Occupancy Issued 37. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement 38. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum 39. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum '10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone N Signature Date Comments ❑ Check here if attachments. =EMA Form 086 -0 -33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. Policy Number: 77 POLK STREET City TYBEE ISLAND State GA ZIP Code 31328 Company NAIC Number. If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View' and "Rear View"; and, if required, "Right Side View" and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. PHOTOGRAPHS TAKEN OCTOBER 07, 2014 FRONT VIEW LEFT SIDE VIEW =EMA Form 086 -0-33 (7/12) Replaces all previous editions. ELEVATION CERTIFICATE, page 4 Building Photographs Continuation Page IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. Policy Number. 77 POLK STREET City TYBEE ISLAND State GA ZIP Code 31328 Company NAIC Number. If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View' and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. REAR VIEW RIGHT SIDE VIEW FEMA Form 086 -0 -33 (7/12) Replaces all previous editions. IMES Evaluation Report ESR -2074* www.icc- es.org 1 (800) 423 -6587 1 (562) 699 -0543 DIVISION: 08 00 00— OPENINGS Section: 08 95 43 —Vents /Foundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 (877) 441 -8368 www.smartvent.com infoO- smartvent.com EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: FLOODVENTTm MODEL #1540 -520; FLOODVENTTm STACKING MODEL #1540 -521; SMARTVENTTm MODEL #1540 -510; SMARTVENTI STACKING MODEL #1540 -511; WOOD WALL FLOOD MODEL #1540 -570; WOOD WALL FLOOD OVERHEAD DOOR MODEL #1540.574; FLOODVENTTm OVERHEAD DOOR MODEL #1540-524; SMARTVENTTm OVERHEAD DOOR MODEL #1540 -514 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2009 and 2006 International Building Code® (IBC) ■ 2009 and 2006 International Residential Code (IRC) Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent® units are automatic foundation flood vents (AFFVs) employed to equalize hydrostatic pressure on nonfire - resistance -rated foundation walls, rolling -type overhead doors and building walls subject to rising or falling flood waters. The Smart Vent® units are intended for use where flood hazard areas have been established in accordance with IBC Section 1612.3 or IRC Section R3222.1. Certain models also allow natural ventilation in accordance with Section 1203 of the IBC or Section 408.1 of the IRC_ 3.0 DESCRIPTION 3.1 General: When subjected to pressure from rising water, the Smart Vent® AFFVs disengage, then pivot open to allow flow in either direction to equalize water level and hydrostatic Reissued December 2012 This report is subject to renewal February 1, 2015. A Subsidiary of the International Code Council° pressure from one side of the foundation to the other. The AFFV pivoting door is normally held in the dosed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the plate to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. The SmartVENT'r" Stacking Model #1540 -511 and FloodVENTTm Stacking Model #1540 -521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The AFFVs comply with the design principle noted in Section 2.6.2.2 of ASCE/SEI 24 for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm /s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent AFFVs must be installed in accordance with Section 4.0. 3.3 Model Sizes: The FloodVENTTm Model #1540 -520, SmartVENT -rm Model #1540 -510, FloodVENTTM Overhead Door Model #1540 -524, and SmartVENTTm Overhead Door Model #1540 -514 units measure 153/4 inches wide by 7314 inches high (400 by 196.9 mm). The Wood Wall Flood Model #1540 -570 and Wood Wall Flood Overhead Door Model #1540 -574 units measure 14 inches wide by 83/4 inches high (355.6 by 222.25 mm). The SmartVENTTM Stacking Model #1540 -511 and FloodVENTTm Stacking Model #1540 -521 units measure 16 inches wide by 16 inches high (406.4 by 406.4 mm). 3.4 Ventilation: The SmartVENT® Model #1540 -510 and SmartVENT° Overhead Door Model 41540 -514 both have screen covers with 1/4- inch- by -1/4 -inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENTTm Stacking Model #1540 -511 consists of two Model #1540 -510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other AFFVs recognized in this report do not offer natural ventilation. 4.0 INSTALLATION SmartVENT® and FloodVENTTm are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. The mounting straps allow mounting in wood, masonry and 'Revised June 2014 /CC-ES Evaluation Reports arc not lobe construed as representing aesthetics or any other attributes not specifically addressed nor are they io be construed �., as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, 11C, express or implied as to anyJinding or other matter in this report, or as to any product covered by the report. Copyright © 2014 Page 1 of 2 ESR -2074 1 Most Widely Accepted and Trusted Page 2 of 2 concrete walls up to 12 inches (305 mm) thick. In order to comply with the engineered opening design principle noted in Section 2.6.2.2 of ASCE/SEI 24, the Smart Vent® AFFVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one AFFV for every 200 square feet (18.6 mz) of enclosed area, except that the SmartVENTTm Stacking Model #1540 -511 and FloodVENTTm Stacking Model #1540 -521 must be installed with a minimum of one AFFV for every 400 square feet (37.2 m) of enclosed area. ■ Below the base flood elevation. ■ With the bottom of the AFFV located a maximum of 12 inches (305.4 mm) above grade. 5.0 CONDITIONS OF USE The Smart Vent® AFFVs described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Smart Vent AFFVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report govern. 5.2 The Smart Vent® AFFVs must not be used in the place of "breakaway walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway walls in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ]CC-ES Acceptance Criteria for Automatic Foundation Flood Vents (AC364), dated October 2013 (editorially revised May 2014). 7.0 IDENTIFICATION The Smart VENT models recognized in this report must be identified by a label bearing the manufacturer's name (Smartvent Products, Inc.), the model number, and the evaluation report number (ESR- 2074).