Loading...
HomeMy Public PortalAbout20150115_CRC_CCPresentation.pdf1/13/15   1   Community Resource Committee Report to City Council January 15, 2015 Memorial  Park  Energy  Project   • 6  City  buildings   City  Hall   YMCA  Gym   YMCA  Fitness  Center   YMCA  Old  School   Classroom   Old  School  Cafeteria   Fire  Department  Admin   • Library   Not  included  in  this  report   1/13/15   2   Background   • Grants  from  Georgia  Environmental  FaciliMes   Authority  (GEFA)   § plans  for  upgrades/retrofits,  geothermal,  wind,   solar   • Savings  to  Energy  Efficiency  and  Renewable  Energy   Revolving  Loan  Fund  for  upgrades  and  renewables   unMl  buildings  are  carbon-­‐neutral/zero  consumpMon   § baseline  is  2008  energy  use   • Then,  savings  to  Tybee  Energy  Loan  Fund  and  the   Property  Assessed  Clean  Energy  Financing  Program   Timeline   • 2010  (Jul/Aug)   § retrofit  buildings:  insulaMon,  thermostats,  lighMng   § install  ground  loop  for  geothermal  system   § develop  best  pracMces  (City  Green  Team)   • 2012  (Jun)   § hook  City  Hall  into  geothermal  system   • 2014  (Aug)   § correct  City  Hall  geothermal  controls     1/13/15   3   JAN  FEB    MAR  APR  MAY  JUN  JUL  AUG  SEP  OCT  NOV  DEC   2008  13265  11814  9574  9150  12459  15374  16159  14884  12439  10739  12510  11951   2010  16455  14127  11048  7918  11830  16317  16267  13996  12170  8460  9661  10590   2011  9291  8399  7789  7997  8267  9656  11163  11649  8952  6677  5733  7193   2012  5040  5858  5760  6578  7738  9385  10172  9862  9483  7252  6234  7064   2013  6464  6439  7339  6608  7384  9430  9246  9482  9403  7403  6762  6733   2014  7319  6903  6404  6412  7861  8456  8921  9403  7679  6693  5606  4796   4000   6000   8000   10000   12000   14000   16000   18000   Ki l o w a '   H o u r s   C o n s u m e d   City  Hall  Energy  Use  History     (account  63044-­‐62008,  rate  PLS-­‐C)   2014     geothermal   correcMon   2008  baseline   2010  retrofits   2012  geothermal   Geothermal  only  decreased  usage  in  summer  months;  correcMon  in  Aug.  2014   Zoning  issues  sMll  remain;  space  heaMng?  move  meeMngs  and  AV  equipment?   JUN  JUL  AUG  SEP  OCT  NOV  DEC  JAN  FEB    MAR  APR  MAY   2011-­‐12  9656  11163  11649  8952  6677  5733  7193  5040  5858  5760  6578  7738   2012-­‐13  9385  10172  9862  9483  7252  6234  7064  6464  6439  7339  6608  7384   2013-­‐14  9430  9246  9482  9403  7403  6762  6733  7319  6903  6404  6412  7861   2014-­‐15  8456  8921  9403  7679  6693  5606  4786   4000   5000   6000   7000   8000   9000   10000   11000   12000   13000   Ki l o w a '   H o u r s   C o n s u m e d   City  Hall  Energy  Use  June-­‐May  since  2011   “baseline”  aher  2010  retrofits   geothermal  hook  up   geothermal   correcMon   1/13/15   4   City  Hall-­‐Yearly  Totals   • 2014:  42%  reducMon  compared  to  2008   • Total  savings  in  5  years:  $32,952   kWh  from  Georgia  Power;  savings  calculated  by  City  Finance  Department;     CO2  equivalent  from  EPA  hjp://www.epa.gov/cleanenergy/energy-­‐resources/calculator.html     2008  2010  2011  2012  2013  2014   Total  kWh  150318  148839  102766  90426  92693  86453   0   20000   40000   60000   80000   100000   120000   140000   160000   Ki l o w a '   H o u r s   2014  bill  total:  $12,182     CO2:  59.6  metric  tons   JAN  FEB    MAR  APR  MAY  JUN  JUL  AUG  SEP  OCT  NOV  DEC   2008  14920  13320  8040  7880  17360  23280  24520  23000  17800  12560  13440  13560   2010  17480  17120  10320  7400  14960  21160  24880  20720  17320  8640  7640  21120   2011  18080  12160  7800  9360  10880  15920  19200  16400  11480  6280  5400  9560   2012  5960  6160  5480  7080  8760  12800  16880  13000  11640  7120  6760  7320   2013  6600  7800  8360  7680  9760  15840  16960  17480  16160  9080  7840  7840   2014  12960  10280  7920  7680  12840  15320  16660  17560  13120  10960  8800  8880   4000   9000   14000   19000   24000   29000   Ki l o w a '   H o u r s   C o n s u m e d   YMCA-­‐Old  School-­‐Cafe  Energy  Use  History    (account  38680-­‐13015,  rate  PLM-­‐C)   1/13/15   5   YMCA-­‐Old  School-­‐Cafe-­‐Yearly  Totals   • 2014:  25%  reducMon  from  2008   • Total  savings  in  5  years:  $33,589   2008  2010  2011  2012  2013  2014   Total  kWh  189680  188760  142520  108960  131400  142980   0   20000   40000   60000   80000   100000   120000   140000   160000   180000   200000   Ki l o w a t   H o u r s   Note:     3  buildings,   different  uses   2014  bill  total:  $19,827     CO2:  98.2  metric  tons   kWh  from  Georgia  Power;  savings  calculated  by  City  Finance  Department;     CO2  equivalent  from  EPA  hjp://www.epa.gov/cleanenergy/energy-­‐resources/calculator.html     JAN  FEB    MAR  APR  MAY  JUN  JUL  AUG  SEP  OCT  NOV  DEC   2008  15440  11200  5360  8640  14560  18400  19080  16120  13720  10920  17160  15360   2010  17600  22240  12760  5280  12400  16360  14040  13280  10040  3840  5080  31360   2011  25520  13480  10960  9120  10400  16040  23200  18880  12520  6640  6520  10840   2012  7880  8520  4760  8000  11800  15960  22880  23840  19960  9480  8480  11240   2013  10720  12040  13760  6880  11160  21600  19880  17120  13040  5880  7240  9640   2014  17120  13600  10760  5600  8480  14040  16560  15760  9320  5880  9360  12200   2000   7000   12000   17000   22000   27000   32000   Ki l o w a '   H o u r s   C o n s u m e d   Gym  Energy  Use  History     (account  04413-­‐70010,  rate  PML-­‐C)     1/13/15   6   Gym-­‐Yearly  Totals   • 2014:  16%  reducMon  from  2008   • Total  savings  in  5  years:  $11,825   2008  2010  2011  2012  2013  2014   Total  kWh  165960  164280  164120  152800  148960  138680   0   20000   40000   60000   80000   100000   120000   140000   160000   180000   Ki l o w a '   H o u r s   2014  bill  total:  $21,070   CO2:  95.6  metric  tons   kWh  from  Georgia  Power;  savings  calculated  by  City  Finance  Department;     CO2  equivalent  from  EPA  hjp://www.epa.gov/cleanenergy/energy-­‐resources/calculator.html     JAN  FEB    MAR  APR  MAY  JUN  JUL  AUG  SEP  OCT  NOV  DEC   2008  2971  1305  772  971  1559  2662  2952  2633  1614  1456  940  2119   2010  4247  2353  1210  1132  2361  3065  4066  3858  3376  2019  1514  2605   2011  2200  1609  1259  2574  3344  4390  5254  4624  3549  2270  1687  1991   2012  1522  902  821  1126  1970  2327  2768  2455  2085  1163  813  1006   2013  847  866  1033  983  1740  2636  2897  3014  2579  1376  1018  958   2014  1581  1357  1157  1366  2336  2751  3079  3206  2235  1592  1205  1194   0   1000   2000   3000   4000   5000   6000   To t a l   K w   H o u r s   Fire  Dept  Admin-­‐Energy  Use  History    (account  58634-­‐62001,  rate  PLS-­‐C)   1/13/15   7   Fire  Dept  Admin-­‐Yearly  Totals   • 2014:  5%  increase  from  2008   • Total  savings  in  5  years:  -­‐$2,564   2008  2010  2011  2012  2013  2014   Total  kWh  21954  31806  34751  18958  19947  23059   0   5000   10000   15000   20000   25000   30000   35000   40000   Ki l o w a '   H o u r s   2014  bill  total:  $4,036   CO2:  15.9  metric  tons   kWh  from  Georgia  Power;  savings  calculated  by  City  Finance  Department;     CO2  equivalent  from  EPA  hjp://www.epa.gov/cleanenergy/energy-­‐resources/calculator.html     Summary-­‐All  Buildings   26%  reducYon  in  kWh   94  metric  tons  less  CO2  (2008  vs.  2014)     $75,802  cumulaYve  savings   (through  2014)   kWh  from  Georgia  Power;  savings  calculated  by  City  Finance  Department;     CO2  equivalent  from  EPA  hjp://www.epa.gov/cleanenergy/energy-­‐resources/calculator.html     2008  2010  2011  2012  2013  2014   kWh  Totals  527912  533685  444157  371144  393000  391072   0   100000   200000   300000   400000   500000   600000   To t a l   K i l o w a '   H o u r s   TOTAL  SAVINGS  THRU  2014   2010  2011  2012  2013  2014  TOTALS   CITY  HALL  $344.07  $6,983.05  $8,623.80  7928.74  $9,072.86  $32,952.53   GYM  $884.17  $940.59  $2,856.06  $2,726.56  $4,417.24  $11,824.62   OLD  SCHOOL  $86.00  $6,847.78  $11,876.11  8394.50  $6,385.02  $33,589.42   FD  ADMIN  -­‐$1,497.65  -­‐$1,859.40  $547.12  421.35  -­‐$175.14  -­‐$2,563.71   $75,802.85   1/13/15   8   Lessons  Learned   • Energy  efficiency  measures  can  work!   • Monitoring  and  maintenance  is  vital.   • Projects  need  independent  oversight  to   ensure  proper  installaMon,  funcMoning,  and   maintenance.   • Consider  commissioning  energy  management   or  issuing  performance  contracts  for  large   projects.   Next  Steps   City  Hall    RenovaMon/rezoning    Geothermal  monitoring   YMCA  Gym    2  new  heat  pumps    Spray  foam  insulaMon  in  roof?    AddiMonal  fixes/retrofits?   YMCA-­‐Old  School-­‐Cafe  Complex    Monitor  separate  buildings?   Fire  Dept.  Admin    Review  best  pracMces    ConMnue  monitoring     Energy  monitoring/dashboard?   Solar?   CITY  HALL   22%   GYM   35%   OLD  SCHOOL   37%   FD  ADMIN   6%   2014  Energy  Use   1/13/15   9   Thank You! Reduce, Reuse, Recycle