HomeMy Public PortalAboutJFOCP 2007-03-29 MEMORANDUM
To: Bruce Hutchins, Grand County No. 1 Water Sanitation District
Kirk Klancke, Winter Park West Water Sanitation District
From: Alison Naschak and Joe Fuqua, Fraser Sanitation District
Date: February 7, 2007
Attached is Joe's Superintendent Report for plant operations for the month of January.
The Town of Fraser has begun the process of dissolution of the Fraser Sanitation District, and we
are now required to follow through with this process. Jim Bailey attended our Board meeting on
February 6 and is going to work with us on the matter. Since we only just received the
application from the Town a few days before our meeting, we did not have an opportunity to
meet with Jim beforehand. Jim will be reviewing various District documents and will attend our
March 6 meeting to discuss a plan for dissolution and other matters related to the process. It will
probably make sense to have Jim attend the April JFOC meeting to help answer questions and
concerns.
The Fraser Sanitation District Board approved a proposal from McLaughlin Rincon to develop a
plan to study alternatives and develop an optimum plan for the use of the sequencing batch
reactor (SBR). The cost is not to exceed $5,000. An update and any other information that has
been provided on the matter will be forwarded to the Committee for the April meeting.
Things have been quiet and the plant has been running well. If you have any questions, please
do not hesitate to call Joe or me anytime.
Thank you,
C1)15N—
SUPERINTENDENTS UPDATE
Plant Operations Update as of 1 February 2007
1_ Temperature Standards: have been approved and are 17C summer and 9C winter.
The last lagoon has not been disturbed and might be helpful to meet. requirements.
The plant has installed temperature recorders to monitor influent and effluent and
would like to install data loggers in river both up stream of plant and down stream
of the mixing zone. This permit standard is going to be a problem, it will be worse
if the river is on 303d list.
2. Generator Set is due for a service. A block heater is broken and will be replaced.
Oil sample are going to be taken and sent to lab for testing.
3. The plant is working very well except for P11 problems that have just started in
January, we have been adding soda ash trying to raise P11 up to 6.5 and are not
having much luck.
4. The bulbs for bank #2 are getting very close to the maximum hours and will need
replacement. Three more computer boards have been ordered. They are being
replaced pro -rata under warranty
n