Loading...
HomeMy Public PortalAboutORD12750 BILL NO. 98-7 y : SPONSORED BY COUNCILMAN_ Jaynes ORDINANCE NO. I9.1759 AN ORDINANCE OF THE CITY OF JEFFERSON, MISSOURI, AMENDING CHAPTER 8 OF THE CODE OF THE CITY OF JEFFERSON, MISSOURI, BY REPEALING THE PRESENT SECTIONS 8-4 AND 8-5 AND ENACTING IN LIEU THEREOF A NEW SECTION 8-4, ENTITLED "ADOPTION OF THE INTERNATIONAL PLUMBING CODE 1997 EDITION," AND A NEW SECTION 8-5 ENTITLED "AMENDMENTS TO THE INTERNATIONAL PLUMBING CODE 1997 EDITION." 1 I BE IT ENACTED BY THE COUNCIL OF THE CITY OF JEFFERSON, MISSOURI, AS ; FOLLOWS: Section 1. Chapter 8 of the Code of the City of Jefferson, Missouri, is hereby amended by repealing the present Section 8-4, entitled "Adoption of BOCA Basic National Plumbing Code 1993 Edition,"and enacting the following new Section 8-4,entitled "Adoption of the International Plumbing Code 1997 Edition Sec. 84. Adoption of the International Plumbing Code 1997 Edition. The International Plumbing Code/1997, published by the Intemational Code Council, Inc. and Building Officials and Code Administrators International, Inc.and Southern Building Code Congress International, Inc. is hereby adopted and incorporated herein by reference as the Plumbing Code Y' of the City of Jefferson, with the additions, insertions, deletions and changes contained in this ordinance. i (Ord. No. 9142, 7-17-78; Ord. No. 10398, 84,4-1-85; Ord. No. 11202:1, 4-17-89' g -if-It (Ord. ' t Cross Reference- Ordinance not affected by Code generally. Section 2. Chapter 8 of the Code of the City of Jefferson, Missouri, is hereby further amended by repealing the present Section 8-5, entitled "Amendments to Plumbing Code 1993," and enacting the following new Section 8-5, entitled "Amendments to the International Plumbing Code 1997": Sec. 8-5. Amendments to the International Plumbing Code 1997. ` The following addition, insertions, deletion and changes in the International Plumbing Code 1997 and contained in Ordinance No. MI%9 shall be as set out below: v, (Page 1) ' Add Section 101.5: f 101.5 The ordinances shall not be construed to relieve the responsibility`or liability of any persons owning, operating, controlling or installing any plumbing or damage caused by any i defect therein, nor shall the City of Jefferson or any of its inspectors, agents or employees, I including its plumbing inspector, be held as assuming any such liability by.reason of the t inspection authorized herein or certificate of approval issued as herein provided. 2„ kx}T Delete Section 103.1, 103.2, 103.3 and 1 03.4 and insert in their place: 103.1 Plumbing Inspector: The administration and enforcement of the plumbing code shall u` be the responsibility of the Director of Planning and Code Enforcement or designated 6:WyFks%CounciAORDINANCM-007.w`d Ens i i. R4 1 1 i aownrn� sr� - 7 representative, the Plumbing Inspector, who is authorized to take such action as may be h reasonably necessary to enforce this ordinance. 103.1.1 Qualifications of Plumbing Inspector:The Plumbing Inspector shall be over twenty- one one (21)years of age, be of good moral character, and be physically able to carry out all the provisions of the plumbing code. The Plumbing Inspector shall have six (6)years experience as a licensed journeyman in the trade, or have two(2) years training in a recognized college f of(Mechanical Engineering and in addition thereto, shall have a minimum of four(4)years of � practical experience in plumbing construction. The Plumbing Inspector shall be a City of I Jefferson licensed journeyman plumber, but shall not be actively engaged in the plumbing l business, nor associated with the operation of any person, firm or corporation engaged in the plumbing business. . 103.2 Appointment of Plumbing Inspector: The Plumbing Inspector shall be appointed by the Director of Planning and Code Enforcement. r 103.2.2 Duties of the Plumbing Inspector: It shall be the duty of the Plumbing Inspector to 4 enforce the provisions of the plumbing code and to make all inspections required thereunder, and to issue all permits, collect all fee's and keep all records required under this ordinance. All fees are to be credited to the General Revenue. The Plumbing Inspector shall also perform all tasks and services delegated by other ordinances or other supervisory personnel. (Page 3) Add 106.3.2 106.3.2 Permit Application: Application for permits for plumbing work shall be made on j, forms provided by the Department of Planning and Code Enforcement. (Page 4) s Xt � Delete 106.4.3, 106.4.4 and insert in their place: 106.4.3 Permits: Plumbing permits shall only be issued to licensed plumbing contractors and { approved qualified home owners. 106.4.4 home Owner Permits: A permit may be issued to a qualified person to do work in a single family dwelling used exclusively for their living purpose, including the usual accessory building and quarters in connection with such buildings, provided that the person is the bona fide owner and shall occupy said dwelling for one (1) calendar year after date.of approved ' final inspection of work covered by the permit. Owner shall purchase all materials and ' perform all labor to complete the plumbing installation. All work performed under this permit ` will comply to all Sections of this ordinance. Qualification shall be determined by a test of basic knowledge of plumbing principles. 106.5.2 Pee Schedule: The fees for all plumbing work shall be as indicated in the following schedule: I�P> Each plumbing fixture $3.00 j s.a Each floor drain, hub drain, floor sink or stand pipe $3.00 w Each roof drain $5.00 Water service (with building permit) 5 # Water Service (existing building) $10.00 Back flow preventer(with building permit)' $5.00' 4� Back flow preventer(Existing building) $10.00 Building sewer(with building permit) $7.00 Building sewer(existing building) $10:00 Private disposal system $15.00 ° C:VAyFkslCmnciAOR01NANC%98&007.wpd 2 + .. a. E r W ` .,.Air��•'V. eft „(. � i41' V Y' d.. .{3, ti .f. 41 Y ,3 r $5.00 ti Back water valve (with building permit) $10.00 Back water valve.(existing building) $16.00 f -` Grease interceptor $15.00 :Ft Oil interceptor $5.00 Water conditioner $10.00 Repair or alteration of any plumbing system $10.00 Inspection or reinspection minimum permit I Delete Section 106.5.3 and insert the following In their place: 106.5.3: Permit fees shall be billed to licensed plumbing contractors the first of each month. t Permit fees are due in month billed, a ten dollar ($10) passed due shall be added to each P ermit fee not paid within sixty (60)days of first billing date. All permit fees and passed due fees not paid within ninety (90) days of first billing date can be collected from contractor's surety bond. Add 106.6.1 the 106.6.1: Notice of inspection; it shall be the duty of the or each�rehui required inspection. The Department of Planning and Code Enforcement to arrange the Plumbing Inspector or Code :`. permit holder shall allow twenty-four (24) hours Enforcement personnel to conduct required inspections during the City's normal working hours. (Page 7) Delete Sections 109.2, 109.2.1, 109.2.2, 109.2.3, 109.2.14, 109.2.5, 109.2.6 and insert in their place: I. 109.2 Board of Plumbing Review and Examiners, Appointment and Term of Office: Division 2 of Article XIII, Chapter 7, establishes a board of plumbing examiners and review with attendant duties and powers. Wh enever reference is made to the "board" in Section 8-4 of Chapter 3 of the Code of the City of Jefferson, Missouri, reference is to the board of plumbing review and examiners. (Ord. No. 11906, § 8, 5-17-93) 109.2.1 Duties of the Board: The Board shall act on a� ,®r agent of or plumbing permit, the holder of plumbing permit, or the al of the structure wherein plumbing work is to be installed. Such grievances shall be an apps decision of the Plumbing Inspector or authorized agent or�ere eta installations a�rnatenals90 be rt. a modification of provision of the plumbing coda governing used. Applications for appeal will be submitted to the Director of Planning and .Code Enforcement or an authorized representative, when it is claimed that: t 1. The true intent of the plumbing code or rules adopted thereunder have been incorrectly interpreted. 1 2. The provisions of the plumbing code do not fully apply. al the l ` ' At such time as the Board of:.Review and Examiners meet to act on such an appeal, 5 appellant,that t Plumbing Inspector shall not'vote. if one of the members of said Board is the apps s; member shall not vote. A simple majority of those voting shell constitute a qualified decision.. } s In the event the voting members of the Board are evenly divided;the decision of the Plumbing Inspector shall be affirmed. The Board shall review all examinations and the plumbing code a minimum of once a year. They shall transmit to City.Council any and all recommendations 3 4 g andlor changes necessary to;.update the plumbing code.. y c.WVFUes n�noaoiwwc%sa oo7.wPd 3 - T4✓ J1 N .I t. 1 ' 4 i . i : . 109.2.2 Meeting of the Board: The Board shall meet at such intervals as may be necessary q for the proper performances, upon call of the Board chairman, but not less than twice a year. Minutes of meetings will be kept on file for Council review. 109.2.3 Licenses: No person, firm or corporation shall install, repair, alter, or extend any plumbing system within the City of Jefferson unless licensed as required in this ordinance. Plumbing System includes the water supply and distribution pipes; plumbing fixtures and traps; soil, waste and vent pipes, and sanitary and storm sewer and building drains; in } addition to their respective connections, devices and appurtenances within a structure or premises and their extension to the purveyors or other water supply and the connection there to a point of disposal. I Add 109.2.3.1 109.2.3.1 Application, Qualification and Pee for Licenses: Persons desiring a license shall complete and submit to the Plumbing Inspector an application for license. (Applications are obtained from the Department of Planning and Code Enforcement). I Add 109.2.4 109.2.4 Plumbing Contractor License: Persons desiring a Plumbing Contractor License shall be or employ full time a licensed Master Plumber and maintain a two thousand dollar ($2,000)surety bond. Said bond shall indemnify and keep harmless the City of Jefferson from all liability from any accidents or damages arising from negligence or unskillfulness in doing or protecting work or any unfaithful or inadequate work done in pursuance of the plumbing Business and that all street and right of way shall be restored to a condition acceptable to the City of Jefferson, Department of Public Works and shall maintain the acceptable condition for a period of one (1) year there after. This license is renewable annually for a fee of($75.00) i seventy-five dollars and shall be renewed during January of the following calendar year: Persons licensed as a Plumbing Contractor shall immediately notify the Plumbing Inspector, i in writing, of any changes of name, address, phone number, or location of their plumbing a business. 109.2.5 Master Plumber Licenses: Persons desiring a license shall have been licensed as a journeyman with the City of Jefferson a minimum of two (2) years or provide proof of licensed journeyman or master experience acceptable to the Board, and score a minimum of 75% on the City of Jefferson's Master Plumber Examination. This license requires a twenty-five dollar($25.00)fee and is permanent unless revocated for cause. 109.2.6 Journeyman Plumbing Licenses: Persons desiring a license shall have been F licensed as an apprentice with the City of Jefferson a minimum of four (4) years and shall have worked under the direct supervision of a licensed journeyman or master plumber during these four(4) years or show proof of four (4) years plumbing experience acceptable to the Board and score a minimum of 75% on the City of Jefferson Journeyman Plumbers Examination. This license requires a twenty-five dollar($25.00)fee and is permanent unless revoked for cause. s Add 109.2.7 109.2.7 Apprentice Plumber License: Persons desiring a license'to work,as an apprentice t plumber shall submit their name, address,phone number and social security number with the ten dollar($10.00)fee to the Plumbing Inspector. This license is renewable each calendar year. Holder of an apprentice plumber license may only work under the direct supervision of a licensed master or journeyman plumber. The ratio of a pprentires'to journeyman or master is two (2)to one (1). w Add 109.2.8 r g .C:WfyFil"CmnclAORDINANCZ8-007.wpd } ,t k �' Vd17A'ipr/k,'}Kiaalh�.A'Ai.HX :w.. I .. 4 ,t + j i r + X 109.2.8 Licenses, Srispension or Revocation: The Board may suspend or revoke the license of any apprentice, journeyman, master or contractor plumber when charges are l ^'` preferred against them by the Plumbing Inspector, and the Board fonds the person charged Y is incompetent or had willfully violated the provisions of this ordinance. Prior to Board action, the person charged shall be given at least ten (10) days notice of the time and place of a formal hearing on said charges and the person charged shall be apprised of the charges. The person charged shall be given the opportunity to appear in person or with an attorney and 4 shall have the burden of showing cause why the license should not be suspended or revoked. The Board shall render its decision within five(5)days. The decision shall be final, no appeal shall be allowed. The Board may drop the charges, suspend the license for such period deemed proper or permanently revoke the charged person's license. Persons whose license has been revoked shall not be permitted to apply for re-licensing for a period of one(1) year, l and must successfully pass required examination for the license. Add 109.2.9 109.2.9 Assignment of Contractor Licenses: No parson licensed as a Plumbing Contractor shall allow this license to be used by others for the purpose of obtaining Plumbing Permits or knowingly allow non-licensed persons to do plumbing work. Add 109.3.1 109.3.1 License Examinations: License Examination shall require a fifty dollar($50.00)fee payable after approval of license application and prior to taking examination. The Board shall establish standards and procedures for examination. The examination shall be of a basic and elementary character but sufficiently strict to test the qualifications of the applicant. All examinations shall be completed within four(4) hours. 1. Master Plumber License Examination shall test of the knowledge of plumbing theory, plumbing practices, water supply safety, and the City Plumbing ' j Ordinance. 2. Journeyman License Examination shall be in two (2) parts: a) a test of knowledge of Plumbing Theory b) a test of skill in the practice of the trade t: . Add 109.3.2 109.3.2 Re-Examination: Persons who fail to pass the examination as prescribed may apply for re-examination after the expiration of one hundred twenty (120)days. Should applicant i fail on re-examination, the applicant may not re-apply for a period of one(1) year and shall be considered a new applicant. (Page 18) Add required dimensions: 305,6 Frost line in City of Jefferson, Missouri is considered 30 inches (762 mm). 305.6.1 Sewer depth: Building sewer that connects to peovate sewage disposal system shall i be a minimum of 24 inches (610 mm) below finished grade at the point of septic;tank l connection. Building sewer shall be a minimum of 24 inches (610 mm) below finished grade. (Page 21) Add to 312.6 Gravity Sewer Test is not required. (Page 21) Add 312.9.1 � f C:V kS%CoundWRD1NMCkW-007.wpd $ j .... ...r.—.r..��...r... .-.•�............... ... .. "[CS`ltii.}��.:a'J'd7��§YtGe r ••i Y 7 h 312.9.1 Testing back flow prevention assemblies shall be by City of Jefferson, Missouri licensed.Journeyman or Master Plumber certified by the State of Missouri as back flow preventer assembly tester. (Page 21) Add 312.9.2 312.9.2 Inspection and tasting of back flow prevention assemblies: After the required test of a back flow prevention assembly at time of installation, the testing requirements shall be the responsibility of the water purveyor. ' (Page 23 and 24) Table 403.1 is hereby amended by deleting Note. E (For Day Nurseries, a maximum of one bath tub shall be required.) "Bath tubs are not allowed in a day nursery. Insert Note G Water Closets for children's use six (6)years and under shall be small size and height, water closet bowl shall not be more than ten (10) inches high without seat, seat shall f be sized to fit bowl. (Page 25) 403.5 is hereby amended by deleting the"Exception"appearing at the end of said section and replacing with the following. Exception: (Does not apply to facilities that prepare or serve food or beverages.) Employee facilities shall not be required in tenant spaces 900 square feet (84m2) or less where the travel distance to a central toilet area does not exceed 500 feet (152m) and such central toilet facilities are located not more than one story above or below the tenant space. ' (Page 38) Delete Tables 605.4 Water Service Pipe, 605.5 Water Distribution Pipe, and 605.6 Pipe Fitting and insert in their place: a Table 605.4 Water Service Pip Material Standard Brass Pipe ASTM B43 Copper on Copper Alloy Pipe ASTM B 42; ASTM B 302 Copper or Copper Alloy Pipe ASTM B 75; ASTM B 88;'ASTM B 251; (Type K, WK, L, WL, M or WM) ASTM B 447 Ductile Iron Water Pipe AWWA C 151; AWWA C 115 Polybuhylene (PB) ASTM D 2.662; ASTM d 2666; Plastic Pipe and Tubing ASTM D 3309; CSA B 137.8 P .. ' Polyethylene PE ASTM D 2737; CSA B 137.3 s 3 plastic Tubing — t ; Table 605.5 Waiter Distribution Pipe 4 y4 !' 15 C:WIyFilesWounci110RDINANC198-007.wpd """..w`.+o.�tuN:rirsaSn+t"+''A«Yata s.yr ,w .... : .. :1•:. .., r;;:�7 j t�.,�c� .—.._ .. _ _. ..� —..•ter'^•.`^^,.—. _ _ r } Material Standard ` Brass Pipe ASTM B 43 ; Copper or Copper Alloy Pipe ASTM B 42; ASTM B 302 Copper or Copper Alloy Pipe ASTM B 75; ASTM B 88; I (Type K, WK, L, WL, M or WM ASTM B 251• ASTM B 447 --- Galvanized Steel Pipe ASTM A 53 "..I Table 605.6 fPi a Fittings Material Standard 1 Cast Iron ASME B 16.4; ASME B 16.12 Copper or Copper Alloy ASME B 16.15; ASME B 16.18; ASME B 16.22; ASME B 16.23; ASME B 16.26; ASME B 16.29; ASME B 16.32 i; Gray Iron and Ductile Iron AWWA C110; AWWA C153 . Malleable Iron ASME B 16.3 r # Polyethylene (PE) Plastic ASTM D 2609 Steel ASTM B 16.9; ASME B 16.11 ASME B 16.2$ , (Page 45) Delete Section 608.16.5 and replace with Section 608.16.5. 608.16.5 Connection to Lawn Irrigation System: The potable water supply to lawn irrigation system shall be protected against backflow by an Atmospheric-type vacuum breaker,,a pressure-type vacuum breaker, a double check-valve assemble or a reduced- '' pressure principle backflow prevbnter. A valve shall not be installed down stream from an atmospheric-type vacuum breaker. Where chemicals are introduced into the system, the potable water shall be protected by a reduced pressure principle backflow preventer. (Page 45) p; Delete Individual Water Supply Sections 608.17.1 through 608.17.8. and replace with 608.17.1: ' 608.17.1: Wells shall be as currently required by the State of Missouri and U.S. n, Government (Federal) requirements. '! ' (Page 49) , Add to,Section 701.4 Sewage Treatment. 701.4.1: Private Sewage Disposal System shall be as currently,required by the State'of M x" ` Missouri Department of Health 19CSR20-3.060 Minimum Construction Standards for on site'sewage disposal system. RSIVIo.701 C:WyFOn%CoundWRDINANC%WW7.wpd 1. l �l. � � r a. a K3 rfi a ar: 4a f➢ 4 i �' .z; X f xw (Page 49) : Delete Tables 702.1; 702.2; 702.3 and 702.4 and insert in their placer Table,702.1 a Above-Ground A lna a and Vent Pipe Material Standard _ _ Acrylonitrile- Butadiene ASTM D 2661:ASTM F628 Styrene (ABS Plastic Pipe) CSAB181.1 Brass Pipe ASTM B 43 r- Cast-Iron Pipe ASTM A 74; CISIP 301; ASTM A 888 Copper or Copper-Alloy Pipe ASTM B 42; ASTM B 302 Copper or Copper-Alloy Pipe ASTM B 75; ASTM B 88 Type K, L, M or DWV ASTM B 251; ASTM B 306. r. 1 Galvanized Steel Pipe ASTM A 53 �f Glass Pipe P ASTM C 1053 ° k. f i=' Polyvinyl Chloride (PVC) ASTM D 2665; ASTM D 2949; A Plastic Pipe (Type DWV) ASTM F 891; CAN/CSA B-181.2 ;a x t , �s r t . fP !t }} Yx n QWyF11"%CouncJ WRDINANC188 007,wpd $ Y , ���•y ..t1f fF rt, t :, Y ...j„ t 1(2 r �� ��?''{�s�l, x �'.{���tt"`(:�����`}�'7 f'�. w.t'�.... .t�, : ' v, ' : •:' F >r is 1 Y r L Table 702.2 underground Buildin praina a and Vent Pipe Material _ Standard Acrylonitrile Butadiene - ASTM D 2661; ASTM F 628 Styrene (ABS) Plastic Pipe _ CSA B 181.1 Cast-Iron Pips ASTM A 74; CISPI 301; ASTM A 888 Copper or Copper-Alloy ASTM B 75; ASTM B 88; Tubing (Type K or L) ASTM B 251 F(Ppov'Ycv;' Plastic nyl Chloride ASTM D 2665; ASTM D 2949; Pipe Type (DWV) ASTM F 891; CSA CAN/CSA-13181.2 7 (Page 50) } Table 702.3 Buildin Sewer Pi e Material Standard Acrylonitrile Butadiene ASTM D 2661; ASTM F 628 Styrene (ABS) Plastic Pipe CSA B 181.1 Cast-Iron Pipe ASTM A 74; ASTM A 888, CISPI 301 Concrete Pipe ASTM C 14; ASTM C 76; CSA A 257.1 r: CSA CAN/CSA A 257.2 Copper or Copper Alloy ASTM B 75; ASTM B 88; Tubing (Type K or L) ASTM B 251 Polyvinyl Chloride (PVC) Plastic Pipe ASTM D 2665; ASTM D 2949; Type DWV ASTM F 891; CSA Can/CSA B 181.2 Vitrified Clay Pipe ASTM C 4; ASTM C 100 f (Page 53) Delete 708.3.5 and insert in its place 708.3.5: 708.3.5 Building Drain and Building Sewer Junction: There shall be a two way or double clean out at the junction of the building drain and the building sewer outside within five 5 Ofeet of the structure unless a different distance is approved. The two way fitting with a single riser r u shall be installed up to finish grade level for installations three feet six inches (3' 6") or less. Two wyes and eight bends (double clean out with wyes arranged so the entire i in can be cleaned)with risers up to finish grade level, for installations over three feet six nches (3'6") A k deep. Plugs and caps shall be of approved type to serve each location. (Page 63) ' 4 Delete 903.1 and insert in its plaice 903.1: . { 903.1 Main Vent Required: Minimum vent size required: Every drainage system receiving discharge of a water closet shall have a minimum of.one - three inch 3" vent or the C:NyFit,,tCounCIMRDINANC%8-007.wpd 9 t, i X ♦�j !P E y Y 4 sk f Y 'Mee "_.._...�..............�.,....._.._._..,...._...__._...,._.... ....._. .....__.._....._ ..,. .._.... ... ... ..__ •-__..... ..... ---._ t I equivalent of three- two inch (2")vents connected to the drainage system and run as direct as possible through to the open air above the roof. (Page 63) 904.1 Roof extension insert 12 Inches (304.8 mn). (Page 68) Delete Sections 917; 917.1; 917.2; 917.3; 917.3.1; 917.3.2; 917.4; 917.5; 917.6; 917.7; and 917.8. Insert in their place 917: 917 Air Admittance Valve: Air admittance valve shall not be installed in the City of Jefferson, Missouri. (Page 72) Add 1003.5.1: 1003.5.1 Grease Interceptor Size: Shall have a minimum of five hundred (500) gallon capacity below the outlet(effluent). (Page 73) i t Add 1003.5.2: 1003.5.2 Grease Interceptor Desibn: The inlet(influent)shall be two inches (2")above the outlet(effluent). A center baffle shall run to within six inches (6")of the bottom inside and be : . sealed to the top and both sides. The outlet shall have a tee baffle with top open and the bottom extended to within six inches (6")of the bottom inside. The inlet shall have a '/.(90°) bend sweep install with the open end down and extended down one foot-four inches (1'4"). There shall be a man hole or holes installed so the entire inside of the interceptor can be z cleaned. Section 3. Saverability. The provisions of this ordinance are severable. If any provision of this ordinance or the application thereof to any parson or circumstance is held invalid, such invalidity shall not affect other provisions or applications of this ordinance which can be given effect without the invalid provision or application. Section 4: This ordinance shall be in full force and effect from and after the date of its passage and approval. t` Passed .�- /cd%- S� Approved: %' ( Presiding Officer Mayor .111• ' 40 ATTEST: APPRP\/ D AST <t .. � 11! ity Cl '�Clt VoUnsQ I' l{l{ c.WyFf1eMCoundWR01NANCUM-W7.wpd 10 1 f, �� f rt"� sr�aY�IY EK"'`t°ua+wr+..+..rew "r^ s ' ` br,r;.ic..3.«"x^'^'vfi'.+FGj u%',Ey,�• n.+•,`;,^'i".�..;� ayi 'r�?. t .. }� t 4:. i