HomeMy Public PortalAbout61 Paddock WayDocumentation Required for Applications Application Type Appropriateness Application OKH Application OKHD-23-97 Submitted On: Apr 12, 2023 Applicant Neal Holmgren 508-744-6284 info@solarrising.net Primary Location 61 PADDOCK WAY BREWSTER, MA 02631 I am applying for a(n): Appropriateness Application Building Use Residential I am the Authorized Agent Owners Email Address sharonmarotti@gmail.com Contractor/Authorized Agent Email info@solarrising.net I would like to see the HDC regulations/checklist -- Detailed Project Narrative that describes the existing conditions of the property and all proposed improvements, including their location within the property and on the structure. Installation of 29 Solaria 400watt roof mounted solar panels and 1 Tesla battery back up unit. Panels to be installed on the east back roof and west middle roof. Panels will not be visible from the street. Total system size 11.6kW. Will You Be Removing Trees as Part of This Project? No Work Being Completed -- Other true Other: Please Explain Solar Specifications: Does your project include (please select all that apply) Foundation -- Siding -- Trim -- Windows -- Skylights -- Roof false Deck & Railing -- Shutters -- Garage Door -- Gutters -- Storm Windows/Door Entry Door 45 Day Waiver Applicant Signature ---- Attic/Roof Venting -- Driveway -- Solar true Solar Panel Color Black Panel Face Type Flat Black WAIVER OF 45 DAY DETERMINATION OPTIONAL The applicant/authorized agent understands and agrees that the determination of the submitted application for Old King's Highway approval may not be made within 45 days of the filing of such application. The applicant agrees to extend the time frame within which a determination is to be made as required by the Old King’s Highway Regional Historic District Act. Section 9- Meetings, Hearing, Time for Making Determinations “As soon as convenient after such public hearing; but in any event within forty five (45) days after the filing of application, or within such further time as the applicant shall allow in writing, the committee shall make a determination on the application.” (Page 11, Old King’s Highway Regional Historic District Bulletin) Applicant understands that the review of this application will be scheduled as soon as the situation allows. Applicant/Authorized Agent Signature true Owner/contractor/agent is aware that a permit is required from the Building Department. (Check other departments, also.) If application is approved, approval is subject to a 10-day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later. All new construction will be subject to inspection by OKH. OKH- approved plans MUST be available on-site for framing & final I, the Owner and/or Authorized Agent, do agree to adhere to the guidelines set forth in the Old Kings Highway Bulletin as well as all local and state regulations. true Application Completeness Checklist Completeness (Appropriateness) New Multi-Entry Section inspections All fees will be doubled for permits not obtained prior to work being started All permit fees and deposits are non-refundable COVER SHEET REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-0 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 SCOPE OF WORK PHOTOVOLTAIC SYSTEM SUMMARY SYSTEM SIZE: DC - 11.600 KW AC - 8.410 KW MODULES: (29) SOLARIA POWERXT-400R (400W) MODULES INVERTER: (29) ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS ELECTRICAL INFORMATION UTILITY COMPANY: EVERSOURCE MAIN SERVICE AMPERAGE: 225A (NEW) GENERAL NOTES: ROOF 1:-ARRAY TILT: 42° ROOF 1:-AZIMUTH: 178° · CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. · CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. · ALL EQUIPMENT SHALL BE LISTED BY U.L. (OR EQUAL) AND LISTED FOR ITS SPECIFIC APPLICATION. · ALL EQUIPMENT SHALL BE RATED FOR THE ENVIRONMENT IN WHICH IT IS INSTALLED. · ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. · ACCESS TO ELECTRICAL COMPONENTS OVER 150 VOLTS TO GROUND SHALL BE RESTRICTED TO QUALIFIED PERSONNEL. · WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. · PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER G.E.C. PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. · PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER G.E.C. VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. · GROUNDING ELECTRODE CONDUCTOR (G.E.C.) SHALL BE CONTINUOUS AND/OR IRREVERSIBLY SPLICED/WELDED. · ALL JUNCTION BOXES, COMBINER BOXES, AND DISCONNECTS SHALL BE INSTALLED IN AN ACCESSIBLE LOCATION. · WORKING SPACE AROUND ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26 GOVERNING CODES & STANDARDS INTERNATIONAL RESIDENTIAL CODE 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 NATIONAL ELECTRIC CODE 2020 1 AERIAL VIEW PV-0 SCALE: NTS 2 VICINITY MAP PV-0 SCALE: NTS PROJECT SITE PROJECT SITE SHEET INDEX PV-0 COVER SHEET PV-1 SITE PLAN AND ROOF PLAN PV-2 ROOF PLAN & MODULES PV-2A ELECTRICAL SITE PLAN PV-3 ATTACHMENT DETAIL PV-4 ELECTRIC LINE DIAGRAM PV-5 WIRING CALCULATIONS PV-6 PLACARDS PV-7 to 14 EQUIPMENT SPECIFICATION ROOF 2:-ARRAY TILT: 26° ROOF 2:-AZIMUTH: 88° MSP 52 ' - 7 " 13 8 ' - 3 " 78'-4" 166'-2" 28 0 ' - 8 " 318'-8" 267'-2" 20 5 ' - 1 1 " REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 1 PLOT PLAN WITH ROOF PLAN PV-1 SCALE: 1/32" = 1'-0" SITE PLAN & ROOF PLAN ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. (E) RESIDENCE (N) MAIN SERVICE PANEL ROOF ACCESS POINT ROOF#1 (8) SOLARIA POWERXT-400R (400W) MODULES ROOF#2 (21) SOLARIA POWERXT-400R (400W) MODULES P A D D O C K W A Y (E) DRIVEWAY PROPERT Y L I N E PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E JB GTW BA T MSP SUB UMCB ACD 1'- 0 " 3'- 4 " 41 ' - 1 0 " 19'-0"4'-11"5'-9" 8'- 6 " 1'- 4 " 10'-3"4'-5"REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 1 ROOF PLAN & MODULES PV-2 SCALE: 1/8" = 1'-0" LEGEND MSP - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - CONDUIT ROOF PLAN & MODULES - JUNCTION BOXJB MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT ROOF DESCRIPTION ROOF TYPE COMPOSITE SHINGLE ROOF ARRAY TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 42°178°2"X8"16" O.C. #2 26°88°2"X8"16" O.C. ARRAY AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 21 441.84 731.07 60.44 #2 8 168.32 215.24 78.20 CB - COMBINER BOX - PV ATTACHMENT @ 48" o.c. (N) UNIRAC RACKING SYSTEM (66) PV ATTACHMENT @ 48" o.c. (N) MAIN SERVICE PANEL (N) TESLA BACKUP GATEWAY ROOF#1 (8) SOLARIA POWERXT-400R (400W) MODULES (E ) B A C K Y A R D NUMBER OF MODULES = 29 MODULES MODULE TYPE = SOLARIA POWERXT-400R MODULES MODULE WEIGHT = 48.7 LBS / 22.1 KG. MODULE DIMENSIONS = 67.8" x 44.7" = 21.04SF SOLARIA POWERXT-400R (400W) MODULES 44.7" 67 . 8 " (E ) F R O N T Y A R D P A D D O C K W A Y ROOF #1 ARRAY TILT - 42° AZIM. - 178° ROOF #2 ARRAY TILT - 26° AZIM. - 88° ROOF#2 (21) SOLARIA POWERXT-400R (400W) MODULES ROOF ACCESS POINT (E) UTILITY METER (N) UNFUSED AC DISCONNECT (N) TESLA POWERWALL 2 BATTERY (N) EMT CONDUIT (N) JUNCTION BOX (N) ENPHASE IQ COMBINER BOX (N) CRITICAL SUB PANEL JB GTW BA T MSP SUB UMCB ACD REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2A SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 2 STRING LAYOUT PV-2A SCALE: 3/32" = 1'-0" ELEC. SITE PLAN CIRCUIT #3 (9 MODULES) 1 ELEVATION DETAIL PV-2A SCALE: NTS (N) UNFUSED AC DISCONNECT (E) UTILITY METER END CLAMPS (N) 29-ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 29 SOLARIA POWERXT-400R (400W) MODULES INVERTER 29 ENPHASE IQ8PLUS-72-2-US MICRO-INVERTER COMBINER BOX 1 ENPHASE IQ COMBINER BOX X-IQ-AM1-240-4 BATTERY 1 TESLA POWERWALL 2 BATTERY AC DISCONNECT 1 60A UNFUSED, 240V NEMA 3R, UL LISTED, CRITICAL LOAD PANEL 1 125A CRITICAL SUB PANEL WITH LOADS UPTO 30A BACKUP GATEWAY 1 TESLA BACKUP GATEWAY ATTACHMENT 66 PV ATTACHMENT @ 48" O.C. MID CLAMPS 48 MID CLAMPS END CLAMPS 20 END CLAMPS CIRCUIT #2 (10 MODULES) DC SYSTEM SIZE- 11.600 KW AC SYSTEM SIZE- 8.410 KW (29) SOLARIA POWERXT-400R (400W) MODULES (29) ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS (02) CIRCUIT OF 10 MODULES (01) CIRCUIT OF 9 MODULES CIRCUIT #1 (10 MODULES) REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 RACKING DETAIL 2"X8" R A F T E R S @ 1 6 " O . C . PV MODULE UNIRAC MID/END CLAMP PV MODULES (E) COMP SHINGLE ROOF SEE (2/PV-3) FOR ENLARGED VIEW (E) COMP SHINGLE ROOF UNIRAC RACKING SYSTEM ECOFASTEN L-102-3 5/32" SS LAG BOLT WITH MIN 2-1/4" THREAD EMBEDMENT, SEALED PENETRATION 2"X8" RAFTERS @ 16" O.C. 1 ATTACHMENT DETAIL PV-3 SCALE: NTS ATTACHMENT DETAIL (enlarged view) PV-3 SCALE: NTS 2 REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 ELECTRICAL LINE DIAGRAM 1 ELECTRICAL LINE DIAGRAM PV-4 SCALE: NTS INTERCONNECTION 120% RULE - NEC 705.12(D)(2) UTILITY FEED + SOLAR BACKFEED 175A + 50A = 225A BUSS RATING x 120% 225A x 120% = 270A DC SYSTEM SIZE- 11.600 KW AC SYSTEM SIZE- 8.410 KW (29) SOLARIA POWERXT-400R (400W) MODULES (29) ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS (02) CIRCUIT OF 10 MODULES (01) CIRCUIT OF 9 MODULES ENPHASE IQ8PLUS-72-2-US MICRO-INVERTER G (N) ENPHASE IQ COMBINER BOX X-IQ-AM1-240-4 15A/2P JUNCTION BOX NEMA 3R ,600V (3) #10 AWG THWN + Red (3) #10 AWG THWN - Black (1) #6AWG CU GND THWN 3/4" EMT CONDUIT (3) ENPHASE Q CABLE EGC #6 BARE CU IN FREE AIR -+++++--- 2 - 1 3 20A/2P L1 L2 GATEWAY = = -+ = = = = = = = = -+++++---- = = = = = = = = = = -+-+-+-+-+ -+-+-+-+ CIRCUIT #1 CIRCUIT #2 20A/2P213 10 50A/2P GEC G (N) TESLA ENERGY GATEWAY 2, 200A RATED, 240V GROUNDING ELECTRODE SYSTEM (3) #6 AWG THWN (1) #6 AWG THWN GND IN 3/4" EMT CONDUIT RUN G (3) #2 AWG THWN (1) #6 AWG THWN GND IN 1-1/2" EMT CONDUIT RUN L1 L2 G N (3) #8 AWG THWN-2 (1) #8 AWG THWN-2 GND IN 3/4" EMT CONDUIT RUN TESLA POWERWALL 2 BATTERY, 13.5kWh (N) AC DISCONNECT: 60A UNFUSED, 240V, VISIBLE LOCKABLE LABELED DISCONNECT NEMA 3R, UL LISTED 30A/2P 90A/2P SOLARIA POWERXT-400R (400W) MODULES 09 (N) 125A SUB PANEL WITH BACKUP LOADS G NL2L1 M (N) MAIN SERVICE PANEL, 225A RATED, 240V TO UTILITY GRID BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V GROUNDING ELECTRODE SYSTEM N 175A 90A/2P (3) #2 AWG THWN (1) #6 AWG THWN GND IN 1-1/2" EMT CONDUIT RUN -+++++---- = = = = = = = = = = -+-+-+-+-+ CIRCUIT #3 21 3 08 1009 09 20A/2P 90A/2P (PV ESS RSD REMOTE DISCONNECT) REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 WIRING CALCULATIONS ELECTRICAL NOTESAC CONDUCTOR AMPACITY CALCULATIONS: FROM ROOF TOP JUNCTION BOX TO COMBINER BOX AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c): + 22° EXPECTED WIRE TEMP (°C): 29° + 22°= 51° TEMP CORRECTION PER TABLE 310.16: 0.76 # OF CURRENT CARRYING CONDUCTORS: 6 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a): 0.80 CIRCUIT CONDUCTOR SIZE: 10 AWG CIRCUIT CONDUCTOR AMPACITY: 40 A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B): 1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS PER STRING CIRCUIT 1 & 2 = 1.25 X 1.21 X 10 = 15.12A CIRCUIT 3 = 1.25 X 1.21 X 9 = 13.61A DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 TEMP CORR. PER NEC TABLE 310.16 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY = 0.76 X .80 X 40 = 24.32A NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 AMBIENT TEMPERATURE SPECS AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -16° 29° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 51° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE MICRO-INVERTER SPECIFICATIONS MANUFACTURER / MODEL #ENPHASE IQ8PLUS-72-2-US AC MAX CONTINUOUS OUTPUT 1.21A AC MAX. CONT. OUTPUT POWER 290W CEC WEIGHTED EFFICIENCY 97.0% AC CONDUCTOR AMPACITY CALCULATIONS: FROM COMBINER BOX TO POI EXPECTED WIRE TEMP (°C): 29° TEMP CORRECTION PER NEC TABLE 310.16: 1.00 CIRCUIT CONDUCTOR SIZE: 8 AWG CIRCUIT CONDUCTOR AMPACITY: 55 A # OF CURRENT CARRYING CONDUCTORS: 3 CONDUIT FILL PER NEC 310.15(B)(2)(a): 1 REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B): 1.25 X MAX AC OUTPUT CURRENT X # OF INVERTERS 1.25 X 1.21 X 29 = 43.86A DERATED AMPACITY OF CIRCUIT CONDUCTORS PER NEC TABLE 310.16: TEMP CORR. PER NEC 310.16 X CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY = 1 X 1 X 55 = 55A REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 PLACARDS CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AT:MAIN SERVICE AC DISCONNECT INVERTER WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.17(E)) LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.54) LABEL LOCATION: CONDUIT, COMBINER BOX (PER CODE: CEC690.31(G)(3)(4) & CEC 690.13(G)(4) WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC 690.17(E), CB CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(4)) ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] WARNING ADHESIVE FASTENED SIGNS: · THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. · WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. · ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13.G.3 & CEC 690.13.G.4) WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized service provider for assistance WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.35(F)) [To be used when inverter is ungrounded] PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 35.09 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(D)(7)) [Not required if panelboard is rated not less than sum of ampere ratings of all overcurrent devices supplying it] SOLAR DISCONNECT LABEL LOCATION: DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.13(B)) CAUTION: SOLAR CIRCUIT ! ! ! ! ! LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. (PER CODE: IFC605.11.1.4) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. PER CODE(S): NEC 2017: 690.56(C)(1)(a) LABEL LOCATION: LOAD CENTER [Only use when applicable for PV load center] NOTICE PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL (N) AC DISCONNECT (N) IQ COMBINER BOX (E) UTILITY METER (N) MAIN SERVICE PANEL (N) SUB PANEL (N) TESLA BACKUP GATEWAY (N) BATTERY REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 EQUIPMENT SPECIFICATION MS P 52'-7" 138'-3" 78 ' - 4 " 16 6 ' - 2 " 280'-8" 31 8 ' - 8 " 26 7 ' - 2 " 205'-11" RE V SH E E T N A M E SH E E T S I Z E SH E E T N U M B E R 61 PADDOCK WAY BREWSTER, MA 02631 AN S I B 11 " X 1 7 " DA T E DE S C R I P T I O N RE V I S I O N S Sig n a t u r e w i t h S e a l PR O J E C T N A M E & A D D R E S S PV - 1 SO L A R R I S I N G L L C 34 8 M A I N S T R E E T , MA S H P E E , M A 0 2 6 4 9 PH O N E # : ( 5 0 8 ) 7 4 4 7 - 6 2 8 4 LIC E N S E # : E L E C T R I C A L 2 2 7 5 0 A SHARON MAROTTI RESIDENCE DA T E : 0 3 / 2 3 / 2 0 2 3 1 PL O T P L A N W I T H R O O F P L A N PV - 1 SC A L E : 1 / 3 2 " = 1 ' - 0 " SIT E P L A N & RO O F P L A N RO O F A C C E S S P O I N T SH A L L B E L O C A T E D I N A R E A S TH A T D O N O T R E Q U I R E T H E P L A C E M E N T O F O F GR O U N D L A D D E R S O V E R O P E N I N G S S U C H A S WI N D O W S O R D O O R S , A N D L O C A T E D A T S T R O N G PO I N T S O F B U I L D I N G C O N S T R U C T I O N I N L O C A T I O N S WH E R E T H E A C C E S S P O I N T D O E S N O T C O N F L I C T WI T H O V E R H E A D O B S T R U C T I O N S S U C H A S T R E E LIM B S , W I R E S O R S I G N S . (E ) R E S I D E N C E (N ) M A I N S E R V I C E P A N E L RO O F A C C E S S PO I N T RO O F # 1 (8) S O L A R I A PO W E R X T - 4 0 0 R ( 4 0 0 W ) MO D U L E S RO O F # 2 (21 ) S O L A R I A P O W E R X T - 4 0 0 R (40 0 W ) M O D U L E S PADDOCK WAY (E ) D R I V E W A Y PR O P E R T Y L I N E PROPER T Y L I N E PR O P E R T Y L I N E PROPERTY LINE JB GTW BA T MSP SUB UMCB ACD REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2A SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 2 STRING LAYOUT PV-2A SCALE: 3/32" = 1'-0" ELEC. SITE PLAN CIRCUIT #3 (9 MODULES) 1 ELEVATION DETAIL PV-2A SCALE: NTS (N) UNFUSED AC DISCONNECT (E) UTILITY METER END CLAMPS (N) 29-ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 29 SOLARIA POWERXT-400R (400W) MODULES INVERTER 29 ENPHASE IQ8PLUS-72-2-US MICRO-INVERTER COMBINER BOX 1 ENPHASE IQ COMBINER BOX X-IQ-AM1-240-4 BATTERY 1 TESLA POWERWALL 2 BATTERY AC DISCONNECT 1 60A UNFUSED, 240V NEMA 3R, UL LISTED, CRITICAL LOAD PANEL 1 125A CRITICAL SUB PANEL WITH LOADS UPTO 30A BACKUP GATEWAY 1 TESLA BACKUP GATEWAY ATTACHMENT 66 PV ATTACHMENT @ 48" O.C. MID CLAMPS 48 MID CLAMPS END CLAMPS 20 END CLAMPS CIRCUIT #2 (10 MODULES) DC SYSTEM SIZE- 11.600 KW AC SYSTEM SIZE- 8.410 KW (29) SOLARIA POWERXT-400R (400W) MODULES (29) ENPHASE IQ8PLUS-72-2-US MICRO-INVERTERS (02) CIRCUIT OF 10 MODULES (01) CIRCUIT OF 9 MODULES CIRCUIT #1 (10 MODULES) The Solaria Corporation 45700 Northport Loop East, Fremont, CA 94538 P: (510) 270-2507 www.solaria.com Copyright © 2022 The Solaria Corporation Product specifications are subject to change without notice. SOL-DAT-0010 Rev 03 8-2022 Solaria PowerX | DC Panel Solaria PowerX-400R Performance Series Achieving over 20.5% efficiency, Solaria PowerX Performance solar panels feature Solaria’s core cell cutting technology, offering higher-power and attractive black-on- black aesthetics compared to conventional solar panels. Solaria has been the market leader in cut-cell technologies for over a decade. With a comprehensive 25-year warranty, PowerX delivers the latest in power and reliability for homeowners. About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 250 issued and pending patents in PV solar cell and module technology. Headquartered in California, Solaria has developed a technology platform that unlocks the potential of solar energy. High Efficiency, High Power At 400 watts and 20.5% efficiency, Solaria PowerX solar panels are one of the highest power residential panels available. High Quality and Reliability State-of-the art cell cutting technology and advanced panel construction ensure that PowerX panels are highly reliable and designed to far exceed the industry-leading 25-year warranty. All Black Aesthetics Compared to conventional panels, Solaria PowerX panels have a more uniform all-black appearance. Best System Value Solaria PowerX solar panels produce more power per square meter area. This reduces installation costs due to fewer balance of system components. Improved Shading Tolerance Sub-strings are interconnected in parallel, which dramatically lowers the shading losses and boosts energy yield. Low Light Performance PowerX maintains high efficiency at low irradiance further ensuring maximum energy yield. The Solaria Corporation 45700 Northport Loop East, Fremont, CA 94538 P: (510) 270-2507 www.solaria.com Copyright © 2022 The Solaria Corporation Product specifications are subject to change without notice. SOL-DAT-0010 Rev 03 8-2022 67.8in 1723.0mm 44.6in 1133.0mm 33.9in 861.5mm 0.8in 20.5mm 0.8in 20.5mm 39.0in 990.0mm 55.1in 1400.0mm NEGATIVE(-) 1100mm[43.3in] POSITIVE(+) 1100mm[43.3in] A B A A A A A A A B 9mm[0.354in] X 14mm[0.551in]8X MOUNTING SLOTS 'B'9mm[0.354in]2X GROUNDING HOLE 1.38in 35.0mm 1.38in 35.0mm 0.05in 1.3mm 0.39in 10.0mm 1.1in27.5mm D C B AA B C D 12345678 8 7 6 5 4 3 2 1 E F E F RE V D 01 01 PowerX Module Datasheet 10/22/2021M. Lau -- SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED: SCALE: 1:10WEIGHT: 27.59 kg REVDRAWING NUMBERDSIZE DESCRIPTIONNAMEDATE THIRD ANGLE PROJECTION DRAWN BY FINISH MATERIAL INTERPRET DRAWINGPER ASME Y14.100-2017INTERPRET GEOMETRICTOLERANCING PER ASME Y14.5M-2018DO NOT SCALE DRAWING APPLICATION USED ONNEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFSOLARIA CORPORATION. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF SOLARIA CORPORATION IS PROHIBITED. 45700 Northport Loop EFremont, CA 94538+1 510 270 2507 www.solaria.com OPS. APPR. P. ADRIANI DCC NO.ENG-D ENG. APPR. DIMENSIONS ARE IN MM [IN]TOLERANCES:ANGULAR: 1.0LINEAR X 3LINEAR .X 0.5LINEAR .XX 0.1 Solaria PowerX-400R Performance at STC (1000W/m2, 25° C, AM 1.5) Solaria PowerX-390R 395R 400R Max Power (Pmax)[W]390 395 400 Efficiency [%]20.0 20.2 20.5 Open Circuit Voltage (Voc)[V]36.9 37.1 37.3 Short Circuit Current (Isc)[A]13.52 13.60 13.68 Max Power Voltage (Vmp)[V]30.6 30.8 31.0 Max Power Current (Imp)[A]12.73 12.82 12.9 Power Tolerance [%]-0/+3 -0/+3 -0/+3 Performance at NOCT (800W/m2, 20°C Amb, Wind 1 m/s, AM 1.5) Max Power (Pmax)[W]290 293 297 Open Circuit Voltage (Voc)[V]34.3 34.5 34.7 Short Circuit Current (Isc)[A]11.01 11.10 11.13 Max Power Voltage (Vmp)[V]28.50 28.60 28.76 Max Power Current (Imp)[A]10.20 10.26 10.32 Temperature Characteristics NOCT [ºC]45 +/-2 Temp. Coeff. of Pmax [% / ºC]-0.36 Temp. Coeff. of Voc [% / ºC]-0.28 Temp. Coeff. of Isc [% / ºC]0.048 Design Parameters Operating temperature [ºC]-40 to +85 Max System Voltage [V]1000 Max Fuse Rating [A]25 Bypass Diodes [#]3 Mechanical Characteristics Cell Type Monocrystalline Silicon Dimensions (L x W x H)67.8" x 44.7" x 1.4" 1723mm x 1134mm x 35mm Weight 22.1 kg / 48.7 lbs Glass Type / Thickness AR Coated, Tempered / 3.2mm Frame Type Black Anodized Aluminum Cable Type / Length 12 AWG PV Wire (UL) /1100mm Connector Type MC4 Junction Box IP68 / 3 diodes Front Load 5400 Pa / 113 psf* Rear Load 2400 Pa / 50 psf* * Refer to Solaria Installation Manual for details Certifications / Warranty Certifications UL 61730 / IEC 61215 / IEC 61730 Fire Type (UL 1703)2 Power, Parts & Labor Warranty 25 years* * Warranty details at www.solaria.com Packaging Stacking Method Vertical / Palletized Panels/ Pallet 31 Pallet Dims (L x W x H)69.3" x 44.3" x 49.3" 1760mm x 1125mm x 1253mm Pallet Weight 745 kg / 1642 lbs Pallets / 40-ft Container 26 Panels / 40-ft Container 806IV Curves vs. Irradiance (400W Panel) 67.8in 1723.0mm 44.6in 1133.0mm 33.9in 861.5mm 0.8in 20.5mm 0.8in 20.5mm 39.0in 990.0mm 55.1in 1400.0mm NEGATIVE(-) 1100mm[43.3in] POSITIVE(+) 1100mm[43.3in] A B A A A A A A A B 9mm[0.354in] X 14mm[0.551in] 8X MOUNTING SLOTS 'B'9mm[0.354in] 2X GROUNDING HOLE 1.38in 35.0mm 1.38in 35.0mm 0.05in 1.3mm 0.39in 10.0mm 1.1in 27.5mm D C B AA B C D 12345678 8 7 6 5 4 3 2 1 E F E F RE V D 01 01 PowerX Module Datasheet 10/22/2021M. Lau -- SHEET 1 OF 1 UNLESS OTHERWISE SPECIFIED: SCALE: 1:10WEIGHT: 27.59 kg REVDRAWING NUMBERDSIZE DESCRIPTIONNAMEDATE THIRD ANGLE PROJECTION DRAWN BY FINISH MATERIAL INTERPRET DRAWINGPER ASME Y14.100-2017INTERPRET GEOMETRICTOLERANCING PER ASME Y14.5M-2018DO NOT SCALE DRAWING APPLICATION USED ONNEXT ASSY PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFSOLARIA CORPORATION. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OF SOLARIA CORPORATION IS PROHIBITED. 45700 Northport Loop EFremont, CA 94538+1 510 270 2507 www.solaria.com OPS. APPR. P. ADRIANI DCC NO.ENG-D ENG. APPR. DIMENSIONS ARE IN MM [IN]TOLERANCES:ANGULAR: 1.0LINEAR X 3LINEAR .X 0.5LINEAR .XX 0.1 Comprehensive 25-Year Warranty Solaria Proprietary and Confidential Information ©2016 Do Not Copy, Replicate, or Reproduce. Years 25-year Power, Parts and Labor from Solaria Typical Tier 1 industry warranty 100% 90% 80% 98% 5 10 251520 86% 81% Wo r k m a n s h i p L i m i t JB GTW BA T MSP SUB UMCB ACD 1'- 0 " 3'- 4 " 41 ' - 1 0 " 19'-0"4'-11"5'-9" 8'- 6 " 1'- 4 " 10'-3"4'-5"REV SHEET NAME SHEET SIZE SHEET NUMBER 61 P A D D O C K W A Y BR E W S T E R , M A 0 2 6 3 1 ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 SOLAR RISING LLC 348 MAIN STREET, MASHPEE, MA 02649 PHONE #: (508) 7447-6284 LICENSE #: ELECTRICAL 22750 A SH A R O N M A R O T T I RE S I D E N C E DATE: 03/23/2023 1 ROOF PLAN & MODULES PV-2 SCALE: 1/8" = 1'-0" LEGEND MSP - MAIN SERVICE PANEL - VENT, ATTIC FAN (ROOF OBSTRUCTION) - CONDUIT ROOF PLAN & MODULES - JUNCTION BOXJB MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT ROOF DESCRIPTION ROOF TYPE COMPOSITE SHINGLE ROOF ARRAY TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 42°178°2"X8"16" O.C. #2 26°88°2"X8"16" O.C. ARRAY AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 21 441.84 731.07 60.44 #2 8 168.32 215.24 78.20 CB - COMBINER BOX - PV ATTACHMENT @ 48" o.c. (N) UNIRAC RACKING SYSTEM (66) PV ATTACHMENT @ 48" o.c. (N) MAIN SERVICE PANEL (N) TESLA BACKUP GATEWAY ROOF#1 (8) SOLARIA POWERXT-400R (400W) MODULES (E ) B A C K Y A R D NUMBER OF MODULES = 29 MODULES MODULE TYPE = SOLARIA POWERXT-400R MODULES MODULE WEIGHT = 48.7 LBS / 22.1 KG. MODULE DIMENSIONS = 67.8" x 44.7" = 21.04SF SOLARIA POWERXT-400R (400W) MODULES 44.7" 67 . 8 " (E ) F R O N T Y A R D P A D D O C K W A Y ROOF #1 ARRAY TILT - 42° AZIM. - 178° ROOF #2 ARRAY TILT - 26° AZIM. - 88° ROOF#2 (21) SOLARIA POWERXT-400R (400W) MODULES ROOF ACCESS POINT (E) UTILITY METER (N) UNFUSED AC DISCONNECT (N) TESLA POWERWALL 2 BATTERY (N) EMT CONDUIT (N) JUNCTION BOX (N) ENPHASE IQ COMBINER BOX (N) CRITICAL SUB PANEL