Loading...
HomeMy Public PortalAbout219 Whiffletree Application H-23-227OKH Application OKHD-23-227 Applicant Bruce Junior 508-291-0007 Ext 1210 @ adriana.sousa@trinity-solar.com Documentation Required for Applications Application Type I am applying for a(n): Appropriateness Application I am the Authorized Agent Contractor/Authorized Agent Email permits.wareham@trinity-solar.com Building Use Residential Primary Location 219 WHIFFLETREE AVENUE BREWSTER, MA 02631 Jaynes s-WvIode Owners Email Address james.a.p.stranger@gmail.com I would like to see the HDC regulations/checklist Detailed Project Narrative that describes the existing conditions of the property and all proposed improvements, including their location within the property and on the structure. Install 13.365kw solar panels will not exceed roof panels but will add 6" to roof height. 33 panels total. NO ESS/NO STRUCTURAL Will You Be Removing Trees as Part of This Project? No Appropriateness Application Work Being Completed Exterior Renovation or Alteration Solar Panels true Other Roof Solar Panel Color Black 45 Day Waiver WAIVER OF 45 DAY DETERMINATION OPTIONAL The applicant/authorized agent understands and agrees that the Painting Deck Expansion Specifications: Does your project include (please select all that apply) Solar true Panel Face Type Flat Black Applicant/Authorized Agent Signature true determination of the submitted application for Old King's Highway approval may not be made within 45 days of the filing of such application. The applicant agrees to extend the time frame within which a determination is to be made as required by the Old King's Highway Regional Historic District Act. Section 9- Meetings, Hearing, Time for Making Determinations "As soon as convenient after such public hearing; but in any event within forty five (45) days after the filing of application, or within such further time as the applicant shall allow in writing, the committee shall make a determination on the application." (Page 11, Old King's Highway Regional Historic District Bulletin) Applicant understands that the review of this application will be scheduled as soon as the situation allows. Applicant Signature Owner/contractor/agent is aware that a permit is required from the Building Department. (Check other departments, also.) If application is approved, approval is subject to a 10 -day appeal period required by the Act. This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later. All new construction will be subject to inspection by OKH. OKH- approved plans MUST be available on -site for framing & final inspections All fees will be doubled for permits not obtained prior to work being started All permit fees and deposits are non-refundable Application Completeness Checklist Completeness (Appropriateness) New Multi -Entry Section I, the Owner and/or Authorized Agent, do agree to adhere to the guidelines set forth in the Old Kings Highway Bulletin as well as all local and state regulations. true THE IDEAL SOLUTION FOR: Roprbpanopon (vUVJ�i nskllopohu,soo owored by Engineered In Germany �5JR Warranty rata. AArlorce 2021 BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology With zero gap cell layout boosts module efficiency up to 20.9%. Q CELLS 944 Sccanw THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY 0 CELLS Is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new 'Quaky Controlled PV" of the independent certification Institute TOV Rhelniand. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Ant LID Technology, Anti PID Technologyt, Hot -Spot Protect and Traceable Quality Tra.Q's' EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (54008a) and wind toads (4000 Pa). A RELIABLE INVESTMENT Inclusive 26 -year product warranty and 25 -year linear performance werrantyx. *APT test conditions according to lEC/TS 62804.1.2016,mathdd A(-15005, 96r9 'Soe deta sheet on rear for NINE' 1plomwhlcn. Q CELI.S MECHANICAL SPECIFICATION Former 74.01n x 41.1.1 x 1.261n (Including Were) (1879mm x 1045mm x 32mm) Wet9ht 48.511:4 122.01:2) Front Cover 0.131n(3.2mm)rherm9Yy pre -strewed glees with enll-retoctlon leChnOb9Y Beck Cow. COmpoele film Frame Ce8 JrmBmn Box 2.09-3.9815.1.26-2361n x 0.69.0.7119 Black onodhad aluminum 6 522monocryslellno O.ANTUM ader hen care (53.101mm x 32.80mm x 15.18 mm),1897, with bypass diodes 4 melt Soler cable:C-0 149.21n (1250mm). (-) .49.21n (1250mM/ Sltubll MC4:IP68 Cable Connector O ' ' I anon. I4=P.M.. ELECTRICAL CHARACTERISTICS POWER CLASS 386 390 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, 5TC7 (POWER TOLERANCE +5W /-OW( 3 396 A08 406 Power et MPP' Pre. (W) 385 390 395 400 455 Shen Clreulf (lunge' Open Circuit Voltage' Gwent el LAPP Volte98 a MPP Eak0noy' Ir v, (AI (V) IA) 10.59 10.65 10.71 10 77 10.83 [VI 35:36 36.62 38.68 37.13 37.39 M1 519.6 519.9 520.1 120.4 120.6 1104 45.18 46.23 45.27 45.30 45.34 11.07 1110 11.14 1117 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITION5. NMOT' Pow.r.t MPP P. (WI 266,8 292.6 296.3 Iw (AI 8.90 8.92 8.95 Vag, [VI 42.62 42.55 42.69 I,.. (A) 8.35 6.41 8.46 V,e., I V I 34.58 34.81 35.03 Eg Short Crm519 Cu9M1 .a Omen Chcv6VOHa98 0 Currant at MPP VoltagmeMPP 3001 8.97 42.72 8.61 35.26 303.8 9.00 42.76 8.57 35.46 'Measurementtalerence9 Pwo3%. IBa: Vy s5% STC:1000 W/m', 2512.0,AML5 eccaellrg b1EC80904-3•'800 W)m'. NMOT. spectrum AM 1.5 O CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At Nest 98%d nominal power during Ent year.Theree(ter. mm. 0.5% degradation per year. AI Nast93.58 d nominal power up to 10 years. At lose 89%41 npmirbl pO.9r up Is 25 years. All date vtlhln measurement tobnnc. es. F.e warrantee In accordance win the wenenty lemrc of the D CELLS sales omrnbeti0n of your ,e9 p9ctiae country. ma IMP «uwec+wr.1 Typical module performance under low irradarrc0 conditions In comparison to STcmndllonrri0d,1000Wtmtl TEMPERATURE COEFFICIENTS TamperMura CO9NIb1Mto(li Tampanaee Coaltklam al P,,, P I%/K) +0.04 Temper8Nr.Co4Rk4nl 0l IA, / [%/KI -0.27 Y [%/0] -0,34 Nomine3 Module°panting Tamperatura NMOT 1°F1 109:5.4(4343'C) PROPERTIES FOR SYSTEM DESIGN Maximum 5wtam Voltage Van [v1 1000(IEc)/10o0(JL) PV module 4L..akeIPn Class 11 Maximum Swigs Fun 6.9n9 [ACC) 20 Mrs Rating based an ANSI/tit 08730 TYPE2 Mex. Design Load, Pint, /Pk/IP 180471 now P4)/55(2680Pa) Permeted Module Temperature -40•F up to0185°F Max. Taal Load, Push/PVIP DM/111 113(9940084(84(4009Pa) O1 0°819940 e051V (-4o•Cw1o+85•0) '0.. Imlellalbn Men. QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION uLe7sc,OEarrganr. terryCoem94 Pv-ITNmeaaer4, ECOa150086,180987(xler, uSmnm a.ease �0wad4. A• uem8 CE 0. n 401 H9400.tel 75.419 43.31 46.019 16501ba 24 24 32 packaging 1940mm 1100 mm 1220mm 75115 peke* p5lehs mogul. Neh: Insuhledm instructions muss 5e I011ovned.S9e the Ins9eXelbna4 operatingmanual or contact ourtachnIcal BOAC. 4988,04 4for Nene, Inlgmetlon on epprowdimteeeeon end teed Ma product. Hlnwlu a CELLS Arlredea Ina 4005pectrum Canter Orlsa, 541a 1400, Irvine, G182616.05.4I T6+194974059961 Ef4ML Inpulrytue9-cellecpm I WEB wxw.R-c.N,ue Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US- 0 • 1. 0 0 O 0 12-25 NEAR WARRANTY • • 0000.13V .ate re • D Optimized installation with HD -Wave technology S1131113AN / Specifically designed o work with power optimizers UL1741 5A certified, for CPUC Rule 21 grid complianc N Record -breaking 99% weighted efficient 1 Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 solaredge.com Small, lightweight, and easy to install both outdoors or indoors G Built-in module -level monitoring C Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solar / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3B00H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH- XXXXXBXX4 • OUTPUT Rated AC Lower Output Maximum AC Power Output AC Output Voltage Min. -Nom. -Max. (211 - 240 - 264) AC Output Voltage Min, -N081. -MOO. (183 - 208 - 229) AC Frequency (Nominal) Maxmum Continuous outer t Current 0240V Maximum Continuous Output Cunent @208V Power Fatter GFDI Threshold _ Utility Monitoring, !Standing ProteC000, :Country Configurable Thresholds INPUT Maximum DC tower 02405 1 4650 Maximum DC Power 02083 ' Transformer -less, Ungrounded Maximum Input Voltage _Nominal DC InpN_Wkage Maximum Input Cunent 0740W- _ 8.5 Maximum Input Current 02086" Max. Input Short Circuit Cunent ev rs_P...._._.Protect0__.._ Reverse -Polarity Protection Ground -Fault Isolation Detection Maximum Inverter Efficiency CEC Weighted Efficiency 3000 3000 3800 0 240V 3300 0 205V 3800 0 2400 3300 0 208V 5000 5000 12.5 16 Ni9httime Power Consumption ADDITIONAL FEATURES Supported o_._._ iaionnerfac Supported Communication Interlaces Revenue Grade Metering, ANSI 012.20 Consumption metering Inverter Commissioning Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 STANDARD COMPLIANCE Safety Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range DC Input Larvik Size / 0 of Strings/ AWG Range Dimensions with Safety Switch (HMO) :. Weight with Safety Switch Noise Cooling Operating Temperature Range Protection Rating m Fa other regaml settegs plena contact SclelEdge support (21 A hlghercaren(sarce maybe used the inverter will finites input current to the values stated InneteeNen sepeRevenue Grade 25pee, PPAp CT0750 0.406,verer wenitt�bcx Grade Production endConssmptcn MeterPM .,...hon. :Sheoo5-US00,10. For consume ...nn currentua,Kformers tined be ordered (4) Full power un to at Must 50'0/12n for cam de -rating information referlm hnp JNrmv.solaredge mnthileWelwlt/FAes/se-IemperaMe-derating.rote-na.Pdl *Seen*mmneophtInc MdabervmW.S0u MIDGE, ea sateen.bp0OPh0RED "OSOMAN = arernann.r.e, in..uwnana al SOlaretheletningles. Inc miler 0Senatmmfcm4thsnare Indemar thelrraped. Wenut 0.ttl63010,yp11p1GMaMS,ll.<ta<b,4a10ro,n mere. 99 16 6000 @1240V 5000 0 2080 60E04 2405 5000 0 2089 59.3.60.60.5" 21 25 I 24 1. Adjustable- 0.85 (o 0.85 1 595 5900 5100 7750 22/10 380 7600 10000 11400 56 2405 VA 100_00 0 2080 11400 0 2405 7600 10000 10000 2085 VA 32 42 9300 _ 11800 1 15500 7750 1 Yes 480 400 13.5 16.5 1.3.5 45 Yes 6003 Sensitivity 99.2 99 < 2.5 20 27 65485, Ethernet Zgsee (optional), Cellular (optional) Van Vac 47.5 A 46.5 A 17650 15500 W iw 1Wdc ! Mt 30.5 Adc 27 ~ Adc Adc 9902400 i 98.502085 ii w Optional'. With the SetApp mobile application using 800 -in Wi-Fi Access Point for Local Connection Automatic Rapid Shutdown upon AC Grid Disconnect UL1741, UL1741 SA, 0L16990, C5A 022,2, Canadian AFC( according to T.I.L. M-07 10(01547, Rule 21, Rule 141/11) FCC Part 15 Class 8 7' Maximum / 1_4.6 AWG 1" Maximum / 1-2 00690/14-60W0 1" Maximum /14-4 AWG 1" Maximum / 1-3 goings / 14.6 AWG 17.7 x14.6 x6.8 /450,370x174 21.3 x 14.6 x 7.3 / 540 0, 370 x185 tin/ mm_ 25.1/11.4 26.2/11.9 36.8/17.6 Ib / kg < 25 <50 r 380 Natural Convection -40 to +140 / -40 to .60" NEMA 40 (Inverter with 5a(e7 Switch) 'F/ -C Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 • YEAR WARRANTY rif PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters / Up to 25% more energy / Superior efficiency (99.5%) / Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization solaredge.com / Fast installation with a single bolt IdO 2i3MOd N m / Next generation maintenance with module - level monitoring / Meets NEC requirements for arc fault protection (AFC() and Photovoltaic Rapid Shutdown System (PVRSS) 1 Module -level voltage shutdown for installer and firefighter safety solar - • / Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Opunu:cl model /typical module compatibility) patibility) P740 P111i P320 I/or high (fol Irir/hcr (fun 60 (-Nil power 'tower60 and 72 111061,102 sO ice11 (0)1 Inodul0s) nodules) P4L10 P401 P4155 P405 P505 (for 721L Uor high do, high ,for high- 1fin 1,11)1101 96 re11 IwwPr 6D vol!ago voltage Cur moaules1 ,no 72 Cell modules) nwduleA modules! n,odulesl INPUT Rated input DC Power1 Absolute Maximum Input 50114ge 01. atlwesl ternperaturo) MPPT Operating Range Maximum Short Circuit Current (t5C) Maximum DC Input Current 13.75 Maximum Elloency Weighted Efficiency Overvdtage Category OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Minimum OulputCurrenl -[ Mrrinnu n Output ;Wage OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Vohage per Power 1 Optimizer 120,1 STANDARD COMPLIANCE EMC safely - Material - UL94V-D, W Resistant 8065 INSTALLATION SPECIFICATIONS Maximum Allowed 5,900 1411430 Compatible Inverters 320 48 350 370 60 80 60 8-48 B-60 11 8-80 8.60 101 11.75 123 1465 99.5 99.8 II 405 485 505 1250 12.5 - 105 1 830' 1510 12.5-83 5050 14 Mc 17.5 037 58 996 % W 15 85 Lac Udc FCC Pe,515 Class 0, 10[6101366Q, 5C61 -6-3 1E0621091 mass 11 safety). UL1741 ,e5 1000 0115olarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 1290153027.5/5.1161U 129 x156 x 33.5 1129 4153 0 29.5 12,.159049.5/5.100301.9 ' 129 x16,7. x 69/ mm /5.1x601.3 /5.106x116 5.1 z6A 123 /in Weight (Including cables) Input Connector 630/1.4 MC40 750/1.7 655/1.5 _ 645/1,9 1064/23 91/8 Single or dual MC40 MC409 Input Wile Length 0.16 /0.52 0.15010.9 10.52 or 2.9510 0.16/052 Out .R Wire type / Connector Output Wire Length operating Temperature Rangev+ Proteebon Rat109 Relative Humidity m Rated whew, twmem..51000 net mmt we 0)0114er'Anted molt O70,lc. Modules 100 up to .96 pdom Idermr1 ore 8b.M 12) NEC 2M7 tenures 9an mpu,'011194 be mote then SW (Prof other connector typal phew roman Wedge V) for dw0verlmm for priedmnnmim 14 two nodes use 04115-00101.9114. In the rase Jan odd numberdWrmdrs in one ,0011 r®4P9 one 0445&NI venial maw eV module Wiwi coonmeng a single =die sea the unused mot correctors with Ile supplied par o1 se* t5) longer Inpp6 me length mewed., ha sere. For 0 910 910 0000 krplh 030 ,41/1-100.40. 81 For 00LMM1ReperaMabae 005T / .19011110.1 *1.1.mg Is aWlkd Rent to Power or...en kmuxabh, 01-RaM9100101st Note for more ocW: D9/2.95 Double Insulated / MC4 1.2/3.9 .40 - 085/ -40 - 0185 IP68/ NEMA6P 0-164 16 Minimum String Length P424 Ft* % (Power Op11r1,ioers) P400. P401 rP4p5, Pd85, P505 edam orn String Length (Paver Opin1nrs) Maximum Power per 511ing 6 25 5700 (6000svhh 5E7600 -US - 5E11400- 0s) 0Pd0Ihel connected a M 18 lA 500 5250 Parade) strings or Diderent Legts or Orientations (n For detailed sruq 401,,9 information ,refer 0 lipOrwarrootareaar1007//0 /S faultrber/sdg-9mgro Pdl 1911 is not aka. to 00 P405/PN5/P505 .911 P1A/P3a04110/P40WPa0' 111 one gong 191 A t9n9 wed 1/0050130 op1Mrem room ro men NEC r56d slxlldoam moutromeraft safer voltage ma. 06'00 the 301/ requirement (Inn For 2r1aV9dd it 6 Avert to irMea on to ESWW pet mrgw,en Ile 95010119oaer Winer. b Mew earn 8009659111 (10 64/277/4000 grid' it is elmwed to wank up m 15A00W per wing when rho mmlmum ewer d'6erence beween each emng h 29050 .0 rr40 T90eil00Np010Mhr0On mspmFDo6W5dah `n coniCm W souuoni yr naemurbernewaneeraMmM d SWREpe 1. No amen Met >Waa210smda.In.au5uNeam Wrge.dhen not. 127500 *DI RoHS intent& KUP-L-TAP® (IPC) Insulation Piercing (Dual Rated) • KWLT.MRIO•Wlbn Pacing connector. • 0ody 6 molded Irom 004,. misnl 4.u4s0 'Van • U1.4610.431:0. C 11ntl and Y GSA GMed. • For use wia mana.e mortar Clan or • Cm•ea y. • 11n Plied copper WMtlba.end aaI04*M6Wtne OA4mnl. • Removed, end Wm. • Dual Redd la Comm . A.mbum Conductor. • ULFI. Edxg, 904/041 2 40-4 AWG 6-14 MG 615 12 079066992622 Grounding Connectors TYPE: LI Lay -In Connector CMC® LI-S ground connectors are manufactured from high strength 6061-T6 aluminum alloy to Insure both maximum strength and conductivity. They are dual rated for both copper and aluminum conductors and are electro tin plated to provide low contact resistance and protection against corrosion. They are designed for use on conduit grounding bushings. The open-faced design allows the Installer to quickly lay -In the grounding conductor as a jumper to multiple conduits with no break in the ground conductor. 90°C RATING (4868 LISTED) Catalog Conde Range Number 1 P�. No. AWO Stud Shot. tt Dimensions, 1nCha• L1-500 1 4 • 14 O.I2 0,78 I 0-58 1-07 U-1120 1 1/0 - 14 0.27 1.17 0.6 1.5 U.2005 2 _ 3/0-6 0.33 1.56 T- 0.8 2 11.2525 2 250. - 6 0.33. 1.79 1 0.8 2.2 1/4.28 UHF• 380.130P85F.- 2006.015 - (5.006.301 MARKING 2—. \1'4.007)/ 10 - - --1.0753.015 [9.87 #.251' [27.183.381 ^0.220 THRII t09WTTHIH .077- MAX Of 60TTOM OF WIREWAY. 00 HOTEMILt PAST WIPEWAY. .3753 .010 (9.9. .2553 6 d51 .1873.010 [1.756.251 FIAPKING;I .1506 ,006 0.816.15) 1.-- _1 �jI 075 ,005 __� �'470 "' 1 (11,991� [0.64*. 03 same A. • I•1 ape 4 yr laulnenTS ,7866,0E 119.95* .251 C00494353 r---1/9-26 X.625 LG. STAINLESS STEEL$LOTE0 SCREW 000201027 (1 0E00 ASSEMBLE SCREW SNUG 7060TTOM C11C U.50-5 eKIM®1 464 CU9AL C002100ISJ FINISH:11NEWE CM5 2 11/17/2009 a.. LAY IN LUG U -50-S >Tia 2.25X 1 0 1 anoe,� c10601016 6061-T6 ALUMINUM CR055 REFERENCE / @r IA 4 CLICKc INSTALLATION GUIDE CLICKFIT ,mnlax Myt elm al 4 >oa EcoFasten -.•�I -. By Installers. The UL 2703 listed ClickFit is one of the fastest installing rail -based systems in the industry. Thanks to its Click -In Rail assembly, the rails can be connected to any of EcoFasten's composition shingle, tile and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust materials, such as aluminum and coated steel, to ensure resistance to corrosion and longevity. ClickFit is tested in extreme weather, wind, fire, and snow conditions. FEATURES • Tool and fastener free rail attachment • Fully integrated bonding • Click -on Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments PAGE 02 CLICK INSTALLATION GUIDE RATINGS Fire Rating** Class A System Fire Rating Max System Voltage 1500 VDC Max Fuse Rating 3114 Certification Conforms to UL STD 2703 Warranty 20 Year Material and workmanship UL 2703 Markings Product listing label Is located on the rail end -caps Roof Pitch 2:12 -12:12 UL 2703 Allowable Design Load Rating 10 psf downward, 5 psf upward, and 5 psf lateral Max Module Size 25.6 sqft Module Orientation Portrait or Landscape Multiple use Rated Components (Position Independent) 1 Mid Clamp, MLPE Clip. and MLPE Bracket ammea lacteal *EcoFasten EcoFasten - By Insta:ters. **Class A System fire rating with Type 1 & 2 PV modules. Any module to -roof gap is permitted, with no skirt required. This rating is applicable with any roof attachment. UL 2703 MARKING EXAMPLE: EcoFasten ESDEC CLICKFIT SYSTEM Intertek TORQUE SPECIFICATIONS Component Torque (in -IN N/A Notes Fully Seat. Use visual Indicator of the black EPOM ring around the bonded washer for torquing. Lag Screw Mid -Clamp 144 End -Clamp 96 Rail Clicker Leveling Bolt 142 Pre -torqued upon delivery. Applies to Tile Hook and L-Foot/Cllcker Hoak Height Boit N/A Lightly clamp hook to flush with top of next tile row Ground Lug N/A Refer to specific ground lug manufacturers installation manual MLPE Cllp 144 MLPE Mount 144 Cn cD PAGE 06 INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM 219 WHIFFLETREE AVE WEST BREWSTER, MA 02631 GENERAL NOTES 1. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR INSTALLNG ALL EQUIPMENT AND FOLLOWNG ALL DIRECTIONS AND INSTRUCTIONS CONTAINED IN THE DRAWING PACKAGE AND INFORMATION RECEIVED FROM TRINITY. 2, THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR INSTALLING ALL EQUIPMENT AND FOLLOWING ALL DIRECTIONS AND INSTRUCTION CONTAINED IN THE COMPLETE MANUAL, 3. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR READING AND UNDERSTANDING ALL DRAWINGS. COMPONENT AND INVERTER MANUALS PRIOR TO INSTALLATION. THE INSTALLATION CONTRACTOR IS ALSO REQUIRED TO HAVE ALL COMPONENT SWITCHES IN THE OFF POSITION AND FUSES REMOVED PRIOR TO THE INSTALLATION OF ALL FUSE BEARING SYSTEM COMPONENTS, 4. ONCE THE PHOTOVOLTAIC MODULES ARE MOUNTED. THE INSTALLATION CONTRACTOR SHOULD HAVE A MINIMUM OF ONE ELECTRICIAN WHO HAS ATTENDED A SOLAR PHOTOVOLTAIC INSTALLATION COURSE ON SITE, 5. FOR SAFETY. IT IS RECOMMENDED THAT THE INSTALLATION CREW ALWAYS HAVE A MINIMUM OF TWO PERSONS WORKING TOGETHER AND THAT EACH OF THE INSTALLATION CREW MEMBERS BE TRAINED N FIRST AID AND CPR. 6. THIS SOLAR PHOTOVOLTAIC SYSTEM IS TO BE INSTALLED FOLLOWING THE CONVENTIONS OF THE NATIONAL ELECTRICAL CODE. ANY LOCAL CODE WHICH MAY SUPERSEDE THE NEC SHALL GOVERN. 7. ALL SYSTEM COMPONENTS TO BE INSTALLED WITH THIS SYSTEM ARE TO BE 91L" LISTED. ALL EQUIPMENT WILL BE NEMA 3R OUTDOOR RATED UNLESS INDOORS. GENERAL NOTES CONTINUED THE DC VOLTAGE FROM THE PANELS IS ALWAYS PRESENT AT THE DC DISCONNECT ENCLOSURE AND THE DC TERMINALS OF THE INVERTER DURING DAYLIGHT HOURS. ALL PERSONS WORKING ON OR INVOLVED WITH THE PHOTOVOLTAIC SYSTEM ARE WARNED THAT THE SOLAR MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT. 9. ALL PORTIONS OF THIS SOLAR PHOTOVOLTAIC SYSTEM SHALL BE MARKED CLEARLY IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE ARTICLE 690 6 705. 10. PRIOR TO THE INSTALLATION OF THIS PHOTOVOLTAIC SYSTEM, THE INSTALLATION CONTRACTOR SHALL ATTEND A PRE-INSTALLTION MEETING FOR THE REVIEW OF THE INSTALLATION PROCEDURES. SCHEDULES. SAFETY AND COORDINATION. 11. PRIOR TO THE SYSTEM START UP THE INSTALLATION CONTRACTOR SHALL ASSIST IN PERFORMING ALL INITIAL HARDWARE CHECKS AND DC WIRING CONDUCTIVITY CHECKS. 12. FOR THE PROPER MAINTENANCE AND ISOLATION OF THE INVERTERS REFER TO THE ISOLATION PROCEDURES IN THE OPERATION MANUAL 13. THE LOCATION OF PROPOSED ELECTRIC AND TELEPHONE UTIUTIES ARE SUBJECT TO FINAL APPROVAL OF THE APPROPRIATE UTILITY COMPANIES AND OWNERS. 14. ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION FOR THE SITE IMPROVEMENTS SHOWN HEREIN SHALL BE IN ACCORDANCE WITH: A) CURRENT PREVNLI NG MUNICIPAL AN0IOR COUNTY SPECIFICATIONS, STANDARDS AND REQUIREMENTS GENERAL NOTES CONTINUED 14. B) CURRENT PREVAIUNG UTILITY COMPANY SPECIFICATIONS. STANDARDS, AND REQUIREMENTS 15 THIS SET OF PLANS HAVE BEEN PREPARED FOR THE PURPOSE OF MUNICIPAL AND AGENCY RENEW AND APPROVAL. ONCE APPROVED. THE INSTALLATION CONTRACTOR IS RESPONSIBLE FOR INSTALLING A11 SYSTEM COMPONENTS AS DESCRIBED IN THE DRAWING PACKAGE. 16 ALL INFORMATION SHOWN MUST RE CERTIFIED PRIOR TO USE FOR CONSTRUCTION ACTIVITIES. ABBREVIATIONS AMP AMPERE AC ALTERNATING CURRENT AL ALUMINUM AF AMP, FRAME APE ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AWG AMERICAN WIRE GAUGE C CONDUIT (GENERIC TERM OF RACEWAY, PROVIDE AS SPECIFIED) COMBINER BOX CIRCUIT CURRENT TRANSFORMER COPPER DIRECT CURRENT DISCONNECT SWITCH DRAWING ELECTRICAL SYSTEM INSTALLER ELECTRICAL METALLIC TUBING FUSIBLE SWITCH FUSE GROUND GROUND FAULT INTERRUPTER FREQUENCY (CYCLES PER SECOND) CB CKT CT DC DISC DWG EC EMT FS FU GFI HL ABBREVIATIONS CONTINUED JB JUNCTION BOX kCMIL THOUSAND CIRCULAR MILS kVA IALO-VOLT AMPERE WV KILO -WATT kWN KILO -WATT HOUR L LINE MCB MAIN CIRCUIT BREAKER MOP MAIN DISTRIBUTION PANEL MLO MAIN LUG ONLY MTO MOUNTED MTG MOUNTING N NEUTRAL NEC NATIONAL ELECTR/CAL CODE Sic NOT IN CONTRACT NO it NUMBER NTS NOT TO SCALE OCP OVER CURRENT PROTECTION P POLE PE PULL BOX P810 PHASE PVC POLY -VINYL CHLORIDE CONDUIT PWR POWER QTY QUANTITY RGS MOD GALVANIZED STEEL SN SOLID NEUTRAL JSWBD SWITCHBOARD TYP TYPICAL U.O.I. UNLESS OTHERWISE INDICATED WP WEATHERPROOF AFMR TRANSFORMER +72 MOUNT 72 INCHES TO 90TTOM OF ABOVE FINISHED FLOOR OR GRADE WHIFFLETREE AVE* n VICINITY MAP SCALE: NTS SHEET INDEX PV -1 COVER SHEET W/ SITE INFO & NOTES PV -2 ROOF PLAN W/ MODULE LOCATIONS PV -3 ELECTRICAL 3 LINE DIAGRAM AP APPENDIX GENERAL NOTES IF ISSUED DRAWING IS MARKED MATH A REVISION CHARACTER OTHER THAN -A', PLEASE BE ADVISED THAT FINAL EQUIPMENT ANDIOR SYSTEM CHARACTERISTICS ARE SUBJECT TO CHANGE DUE TO AVAILABLITV OF EQUIPMENT. Issued / Revisions fiStilIOTO 9.1.63 NO. (1E53810710N DATE Project Tile: STRANGER, JAMES - TRINITY ACCT 6: 2023-00-319876 Project Address: 219 WHIFFLETREE AVE WEST BREWSTER, MA 02631 41.7391657131902756,-70.140998555 37575 Drawing Tate: PROPOSED PV SOLAR SYSTEM Drawing Information DRAWING DATE DRAWN BY: REVISED BY: 4/19/2023 NH System Information: DC SYSTEM 5101: 13365k W AC SYSTEM SIZE: 10kW MODULE COUNT: 33 MODULES USED: I HAMM 40S MODULE SPEC B: WEAK DUO BLK MUG10a 40S UTILITY COMPANY: EVERSOURCE UTILITY ACCT 6: 13940900080 UTILITY METER 1: 2322241 DEAL TYPE: SUNNOVA Rev. No. Sheet _P1 PV -1 n r t SOLAR 2211 Allenwood Road 377.765-7283 Wall, New Jersey 07719 www.Trinay-Solar. ram NOTES: 'REFER TO NODULE SPECS FOR MOQUL DIMENSIONS 'DEPICTED MODULES MAY BE PORTRM OR LANDSCAPE ECOFASTEN CLAMP -- NEW PV SOLAR MODULE, TYPICAL _ MUER.TO SPEC SHET FOR OETALM (REFER TO EQUIPMENT SCHEDULE FOR SPECS AND QUANTITIES) SOLAR MODULE SOLAR MODULE '` i * / -I- F _� _ NEW MOUNTING FOOT/ATTACHMENT POINTS, TYPICAL (REFER TO ENGINEERING LETTER FOR SPACING io AND DETAILS/ NEW ECOFASTEN RML,TY%CAL TOUCTUMOUNTED E(REFERTOECVURTO STRUCTURE (REFER TO ECOFASTEN SPECIFICATION I DATA SHEET FOR ECOFASTEN 1_. FOOT PEC (REVERT° S ME O ET FOR IW I.M EXISTING ASPHALT SHINGLES cREFER T° EN°IHLER9 LETTER FM. SRCR G� ECOFASTEN RAIL I REFER TO WEL SKR FOR IWWILM ECOFASTEN PUSHING IRf:Tm T°'Am SHEET FOR DSTALSI ^ g+ � 0 ,/ >y 27 !J _ titi z -- EAI� ` 4 - DETALS) - S.S. LAG BOLT SC \ / 09 _` __ ; _` NEW END CUP. TYPICAL (REFER TOECOFASTEN SPECIFICATION I DATA SHEET FOR DETAILS) APOC SEALANT (REPEAT° EHCINRERS..ITER FORMEC= EXISTING RAFTER (REFER TO DOWERS I. MEP Spy / SOLAR MODULES SHALL NOT 1 f -V( FX0FEO PEAK HEIGHT. WI DETAIL- NEW MID CLIP, TYPICAL I REFER TO ECOPASTEN SPECIFICATION /OATH SHEET FOR DETAILS; CHMENT ON ASPHALT SHINGLE ROOF OUND LEVEL TO PEAK OF ROOF DrV00MODOUTO 6001E aHEIGHTOFROM ue El 909LA 9099090008 LLJJaa ARRAY SCHEDULE Issuod /Revisions 1 — _ I 1 1 FRONT ,„PL4roRA.HR,R„R9RNR NO. 1 DESCRIPTION DATE Project Title: STRANGER, JAMES- TRINITYACCT6:2023-06.914676 I I FRONT r 2 • IIIIrrI �I EP ` D i Project Address: Pro 219 WHIFFLETREE AVE WEST BREWSTER, MA 02631 41.739165781902756,-70.140998555 37575 ��I WIC `'��"{��'"��� 1 1 1 l 'I 1 L , o �i;i' DC *- 1 AC Drawing Title: Trull, PROPOSED PV SOLAR SYSTEM BACK - //.(/ .///f/ 3;4 CtBAjt'PATH �j// / Drawing Information 1 1 / R3 DRAWING DATE: 900380DRAWN Y: TENSED ST: 9/19/2023 NH I — LINE( 111 III f/Q- I■I --I 1 �,� em Information: DC SYSTEM SIZE: ACMTEM WE: MODULE COUNT: MODULES USED: MODULE SPEC R: UTILITY COMPANY: UTILITY ACCT R: UTILITY METER 2: DEAL TYPE: 13.365kW IOkW 33 HANWHA 405 °.PEAR OUOSLR ML -610,405 EVERSOURCE 13940900080 2322241 3094000 I (PROPERTY - .....• L f NOTES: 1.1 ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2.) ARRAY BONDING TO COMPLY WITH MANUFACTURER SPECIFICATION. 3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4J AN AC DISCONNECT SHALL BE GROUPED WITH INVERTER(5) NEC 630.13 I EI 5J ALL OUTDOOR EQUIPMENT SHALL BE RUN TIGHT WITH MINIMUM NEMA 3R RATING. 8) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY SHALL NOT EXTEND BEYOND THE EXISTING ROOF EDGE. BACK Rev. NO. Sheet F�,F 1�,J1 Fes` PV SYMBOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE ROOF DESIGNATION. REFER TO INDICATES PO DISCONNECT —I QTY SPEC 9000/1 ®INDICATES ARRAY SCHEDULE FOR MORE INFORMATION UD NEW UNFUSED TO BE I INSTALLED OUTSIDE ( UTILITY ACCESSIBLE) (I INDICATES NEW PV ONLY SUBPANEL 33 HANWHA 445 (WEAK DUO BLK ML -0108405) • �i J,, ■ ' ■l ■1 ssss® T UlF5:2D PIT[H:3] ORIENTATION:2i8 M INDICATES EXISTING METER LOCATION , INDICATESNEW PVSOLARE41030NVERTER5LES INOIWTE PANELS THAT U5E MICROINVERTE5. D� REFER TO EQUIPMENT SCHEDULE FOR SPECS. INDICATE NEW DC DISCONNECT I $ElOpoaN-USOWBEi4 ROOF; - - — OTHER OBSTRUCTIONS PITCH; 3) Eelu ORIENTATION:96 ROOF INDICATES EXISTING ELECTRICAL PANEL IIJEP LOCATION: INSIDE P INDICATES NEW PRODUCTION METER TO BE INSTALLED OUTSIDE. SD INDICATES EXISTING SERVICE DISCONNECT SOLAR 2211 M1enw°°tl R°atl 6]7.786]283 WAIL New ry0T719 wPnv.Trinl77.786.7283 MOOUlFS:2 %TCH:10 ORIENTATION:98 INDICATES NEW FUSED PV DISCONNECT TO BE r IN STALLED OUTSIDE (UTILITY ACCESSIBLE) INDICATES NEW INVERTER TO BE INSTALLED OUTSIDE. T3 REFER TO EQUIPMENT SCHEDULE FOR SPECS INDICATES EXISTING TRANSFER SWATCH _. Engineer) License Holder: ARRAY CIRCUIT WIRING NOTES 1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY FOR DETERMINING ONSITE CONDITIONS AND EXECUTING INSTALLATION IN ACCORDANCE WITH NEC 2023 2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP= -1600 3.) HIGHEST cowl NUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP= 33-C 4.12005 ASHRAE FUNDAMENTALS 25 DESIGN TEMPERATURES DO NOT EXCEED 47"C IN THE UNITED STATES (PALM SPRINGS, CA 15 44.00). FOR LESS THAN 9 CURRENT -CARRYING CONDUCTORS IN A ROOF -MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47'C OR LESS (ALL OF UNITED STATES( 5.1 PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH NEC 690.12(0( THROUGH (DI 6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC SOURCE AND OUTPUTCIRCUIT AS PER NEC 690.41 (JU[41 7.) UNGROUNDED DC CIRCUIT CO NDUCTORS SHALL BE IDENTIFIED WITH THE FOLLOWING OUTER FINISH: POSITIVE CONDUCTORS = RED NEGATIVE CONDUCTORS = BLACK NEC 210.5(092) 8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE 410 PV WIRE TYPE RH W-2 OR EOUIVELANT AND SHALL BE PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24" SHALL CONTAIN 5 2D CURRENT CARTING CONDUCTORS AND WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN 5 9 CURRENT CARRYING CONDUCTORS. 9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS OTHERWISE NOTED 10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON ROOFTOP AND SHALL BE LIMITED TO 12" IF USED OUTDOORS 11.)OVERCU RRENT PROTECTION FOR CONDUCTORS CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE LOCATED WITHIN 10' OFTHE POINT OF CONNECTION NEC 690.9(0]13)12) 12.) WHERE TWO SOURCES FEED A BU55BAR, ONE A UTILITY AND THE OTHER AN INVERTER, PV BACKFEED BREAKER(5) SHALL BE LOCATED OPPOSITE FROM UTILITY NEC 705.12(8(13)(2) 13.1 ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY GENERATION CIRCUITS AND NO UNUSED muttons 09 LOADS 14.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE A NEMA 3R RATING CALCULATIONS FOR CURRENT CARRYING CONDUCTORS REQUIRED CONDUCTOR AMPACITY PER STRING [NEC 690.818))1)]:115.80'1.2511= 18.75A AWG 410, DERATEO AMPACITY AMBIENT TEMP: 33'C, TEMP DERATING FACTOR: 96 RACEWAY OERATING = 6 CCC: 0.80 (40'36)0.00=30.72* 30.726=18.75A, THEREFORE WIRE SIZE 15 VALID TOTAL AC REQUIRED CONDUCTOR AMPACITY 42,006.025 = 02.50* AWG 46. DERMED AMPACITY AMBIENT TEMP: 3000, TEMP DERATING: 1.0 RACEWAY DERATING ` 3 CCC: N/A 75.4'1:0= 75A 7500 52.50A, THEREFORE AC WIRE SIZE 15 VAUD CALCULATION FOR PV OVERCURRENT PROTECTION TOTAL BKVERI ER CURRENT: 42.00A 42.DDA•1.Z5=52.500 -.O GOA OVERCURRENT PROTECTION IS VALID EXISTING 10120/2400 UTILITY METER SOLAR MODULES MOUNTED -TO ROOF ON 3 ARRAYS 33 - 405W MODULES W/ 150LAR EDGE 5440 PEP MODULE 15 ADC MAX PER STRING 3 STRINGS OF 11 MODULES IN SERIES -4004940 '3 STRINGS TO BE TERMINATED IN PARALLEL INSIDE INVERTER 1 NEW TAP BOX INSULATED BARREL LUGS INSTALLED ON MAIN FEEDERS } NEC 705.11 2400 100A MAIN BREAKER 100A BUS8AR 10 .21 EXISTING MAIN BREAKER LOAD CENTER PV MODULE SPECIFICATIONS HAN W HA 405 (OPEN( DUO RUC ML -510+405) Imo vmp Voc 110 10.53 37.39 45.34 11.17 INVERTER KI-SE10000H-US000BEi4 DC AC Imp Vmp 000 Ise 27 400 430 45 Pout 110000 (max OCPDmin 000m .42 52.5 240 JUNCTION BOX NOTE: INTEgNAL REVENUE GRADE MONITORING CONTAINED WITHIN SOLAR EDGE INVERTER SOLAR EDGE PN. RWND-35-240-MB LOCKABLE 60A DISCONNECT FUSED W/ 60A FUSES 240V 10 071,000 r SQUARE D P610222505 INVERTER N1 ./� . r0f0jo IoIQI 0 0 J r 0 _�f 0 NOTE CONDUIT TYPE SHALL BE 0905141 BY TIIEINSTALLATION CONTIIACTO,. TO MEET OR EKCEFO NEC AND I OC4L 0100 REQUIREMENTS A 46THWN-26E000 EXISTING GROUND ROD B 3/4" CONDUIT W/2-K6TNWN'2, 1410 THWN-2,1-KI0 THWN-2 GROUND C 3/4"CONDUITW/6'X10TNWN-Z,1.0101HWN-2 GROUND D 3/4"CONOUIT w/ Ka Lo niWN'2, 1-K10 THWN-2 GROUND E 3/4"CONDUIT W/2.46THWN-2, 1410 THWN-2, 1'41DTHWN-2 GROUND F 410 PV WIRE (FREE AIR) Win BARE COPPER BOND TO ARRAY G 3/4" CONDUIT W/2-K6THWN-2,1.08 THWN-2 Issued 1 Revisions NoHNN N0. DESCRIPTION DATE Project Title: STRANGER, JAMES - TRINITY ACCT X: 2023-08-914876 Project Address: 219 WHIFFLETREE AVE WEST BRE WSTER, MA 02631 41.739165781902756,-70.140998555 37575 Drawing Title: PROPOSED PV SOLAR SYSTEM Drawing Information DRAWING DATE: 9/19(2023 DRAWN BY: NH REVISED BY: /stem Information: ITC SYSTEM 512e 13.3654 W AC SYSTEM 5125: 10kW MODULE COUNT: 33 MODULES USED: HANWHAAOS MODULE SPECK: Q PEAK DUO BLK MLGIO.40S UTILITY COMPANY: EVERSOURCE UTILITY ACCT p: 13940900080 UTILUY METER 4: 2322241 DEAL TYPE: SUNNOVA Rev. No. P Sheet PV -3 igmh Trinity® SOLAR 2211 Allenwood Road 277-706.7183 Wall, Newler4 507719 www.Triniry-Solar.com MATERIAL LIST (FOR INTERNAL USE ONLY) JOB NAME: STRANGER, JAMES - ADDRESS: 219 Whiffletree Ave West Brewster, MA 02631 41.739165781902756,-70.14099855537575 Tr1'n ity SOLAR 2211 Allenwood Road 877-786-7283 Wall, New Jersey 07719 www.Trinity-Solar.com 91.5455 ESTIMATED PERSONNEL HOURS 3.81 DAYS 2.86 DAYS 1.91 DAYS • 33 HANWHA 405's (13.365KW) (CREW OF 3) (CREW OF 4) (CREW OF 6) • 3 SEPARATE ARRAYS • 20' PEAK TO GROUND • 33 PORTRAIT & 0 LANDSCAPED • 1 INVERTERS INSTALLED OUTSIDE • NO TRENCH ESTIMATED SENT TO JOB USED ❑ HANWHA 405 (Q.PEAK DUO BLK ML -G10+ 405) 33 ❑ S440 SE OPTIMIZERS 33 ❑ SE10000H-US000BEi4 1 ❑ 60A OUTDOOR FUSED DISCONNECT W/ (2) 60A FUSES 1 ❑ 60A OUTDOOR NON -FUSED DISCONNECT 1 o SOLADECK BOX(ES) & HAYCO CONNECTOR(S) 3 o PV LEAD WIRE 150' o INSULATED BUG BITES (LINE TAPS) 2 o ECOFASTEN 2012025 CF STD RAIL MLL AL 171.5 20 o ECOFASTEN 2012013 CF RAIL SPLICE 9 ❑ ECOFASTEN 2099017 CF END CLAMP 32MM BLK 36 ❑ ECOFASTEN 2099022 CF MID CLAMP SHORT BLK 48 ❑ ECOFASTEN 4011011 MODULE JUMPER 6 ❑ GROUNDING LUG (NOT PROVIDED BY ECOFASTEN) 3 o ECOFASTEN 2012022 CF UNIV L -FOOT MLL 3 80 o ECOFASTEN 3012020 GF-1 FLASHING GLV BLK 8 x 10 80 o ECOFASTEN 2012019 CF MLPE MOUNT 33 o ECOFASTEN 2012020 CF WIRE MGMT CLIP 33 o ECOFASTEN 2012024 CF END CAP 36 Trinity® SOLAR 2211 Allenwood Road 827.186-7281 Wall, New Jersey 07719 www.Trinity-Solar.Tom INSTALLATION OF NEW ROOF MOUNTED PV SOLAR SYSTEM STRANGER, JAMES - L17 vvnlrrLC 11.CC HV C WEST BREWSTER, MA 02631 41.739165781902756,-70.140998555 APPENDIX CONTENTS LABELS, STICKERS, AND PLACARDS EQUIPMENT DATA SHEETS NOTES, 1.) COMPLIES WITH NEC2023 2.) REFER TO SHEET PV -3 FOR 5RE SPECIFIC VALUES REQUIRED BY NEC 690 3.) STICKERS, LABELS, AND PIACKARDS SHALL BE OF SUFFICIENT DURRABILO'YTO WITHSTAND THE ENVIROMENT INVOLVED To be located an all DC junction boxes and every 10' on DC conduit 10WINSIBEC. NEC 690.31(D)l2) DC Junction Box NEC 690.56(C Service Disconnect Saladeck SOLAR PV SYSTEM EQUIPPED MTH RAPI0OHUIDOWN NEC 690.56(C) If System is Backfed Breaker INIMIMMWIL NEC 705.12(0(3)(M) IMO NEC 690.54 DC Conduit Mein Service Panel Utility Utility Meter Socket NEC 690.13(8) l'ar. 690.56(0(2 Lovtaxze NEC690.13(B) NEC 690.54 I rf Soler Meter Socket Photovoltaic AC Disconnect NEC 690.54 Load Center (To Combine Inverters) 69256([)(2 MEM NEC 690.13(6) V1rl)t0WIJ1 TAIC „ 7NI4�CT NEC 690.4(B) MA%MAUM EC VOLTAGE GF PV SYS r6M NEC 690.53 • NNW r Inverters) Tr i n_ity® SOLAR NIE 690.4(8) NEC 690.53 DC Disconnect IM ME Oee.ece anaaT +.o NEC 690.13(6) Enphase Envoy Box Q.PEAK DUO BLK ML -G10+ SERIES 385-410Wp 1 132CeIIs 20.9% Maximum Module Efficiency MODEL 0 PEAK 01)0 61.3) ML'G10- 6 bulbar cell technology The Ideal solution for. Rooftop arrays on reslden0el buildings i2 bulbar cell lechnot0gy i acells Breaking the 20% efflclency barrier 0.ANTUM DUO Z Technology with zero gap call layoul boosts module efficiency up to 20.996, A reliable investment Inclusive 25.year product warranty and 25 -year tlraeer performance warranty, Enduring high performance Lang.term yield security with Anti LeTID Technology, Anti PIO Technology' and Hot -Seel P101e01. Extreme weather rating High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000Pa). Innovative all-weather technology Optimal yields, whatever the weather with excellent law.IIght and temperature behaviour. The most thorough testing programme in the industry Ocelis Is the first solar module manufacturer t0 pass the most comprehensive quality programme in the Industry. The neso*Quality Controlled PV of the independent certification Institute TOV Rheinland 'See au d. rearmr runner Inlon.eon. ' APT Mat cwaNwne arsekJrv4'w ICC/ 0&•.600.1:2015. rr.oc1Ai-15,10 V. 961 ( DUO BLK ML -G10+ SERIES ■ Mechanical Specification Formal 74.01n . 41.111.1.261n (including frame) (1879 mm .1045 mm . 32 mm) WatpM 48.51be)22.04R Front Cover 013 in 132 mm} thermely pre -stressed glass wen one-refk0bn technology Back Cover Compositelkn Frame Black anodised aluminium GY 6 . 22 mcnoclyslalllne O A NTUM solar half cells Junction boo 2.09-3.90 in.1.26-2.36in . 0,59-0.7111 F3.101 mm. 32-60mm • 15.16mm1, 467, ellh bypass diodes 11.bM 4mms Soler Cable: (,) 249.2 In 31250ova ]-)x49.2116250 mm) Connector 51961:4114C4. iue a IGI=aa� ■ Electrical Characteristics rows, CLASS 3i{ 7{{ {{{ 400 AO{ •W MINIMUM PER404644NCE AT STANDARD TEST CONDITIONS. 5TC' POWER TOLERANCE +5W1-0,91 Power et MPP' P,ea (W) 395 390 395 400 405 410 Short Orr -Wt Currant' I,,, W 11.04 11.07 11.10 11.14 6.17 11.20 __. Open groat voiaw' V M 4519 45.23 45.27 45.30 45.34 45.37 Currant et MPP Iw. [Al 10.59 10.66 10.71 10.77 10:00 10.89 VoY.paat MPP Vas. (VI 36.36 36.62 36.88 37.13 37.39 _ 37.64 __.... .r. . . E11kMrrcy' n IN 219.6 2199 2201 620.4. 210.6 220.9 MINIMUM PCRFOR610NCE Al NO RMA. OPERATING CONOTIONS. NMOP Power at MOP Pµ. (W[ 2868 292.6 296.3 3001 303.8 3078 ._-._ g Circuit Conant . Short t Cu rrt 6c Al 8.90 8.92 8.95 8.97 9.00 __- 9.03 _-_ Open Circuit lVoltage _....., V4s M 42.62 42.65 42.69 42.72 42.76 6279 � Cornet et MPP 4e. [A1 1335 BAt 9.46 8.51 8.6] 0:62 V4Y.9. at MPP d,,,. 41) 34.59 34.81 36.03 35,25 35.46 35.68 Measurement tolerances P,n 93X Iz Vac 15% at STC: 1000 W/m; 2542 C, AM 1.5 according to IEC 609043 • 'B00 W/mo, 6807, spectrum AMU 0911 PERFORMANCE WARRANTY rent Sex of nom. peer duo%awly.. Two.. mea a d05%rr,neaaI80wt, astl 93.6% of non*. power not I0yeere MM me rte In...le to 2byean 11.1 .u9FO mwm fam r MMrarc<01a FUN warrantee ode Cf Mth IM WSW./ Wrlet alew ant was 099165 m of your reep.[We country. wa.tl anwrae ° p. 202111 1.rew.r iw.rem� •aa, e. TINAIMPRATURE COEFF7O PNTS ,Temperature Coenctert Tempetnwe Caetacl.m ■ Properties for System Design Maximum 9ietem 5106. , Vsw M [%/In Y (%/M .0;04 -034 100054g11000411) Mari/nun Series Rem Patine fA DG 20 Max. Deafen Load, PAM ¢Pulp_ 1,1% HP] 7513600 Pat, 55 [2660Pa) Max. Test Load, Push/Punt lies/al 113 ]5400Pe1184 ]4000Pe) =Sae Installation Manual ■ Qualifications end Certificates UL emo.CE-comp.., Ounlry Cammpad W -TUV and.erd, ICC 61214:20M. 010,2115(selr J.S. Poles ate. Aa93,2K ryaler nlML Ae E Cµ 6 PERFORMANCE AT LOW IRRADIANCE S ml ioaoea: rI v mmasarwa em Ga2AIXAMA .auym. L' T.0rpa.pyn Oo.teca re of Vy. Hoofbeat Module Operating Terep.rnee PV module c.dnn.8on Hoe Rating !mad= ANSI /1.1L 61730 P.nnM.d Module T.mp.r3Nn on fpWnua., MAY NWT tysJai -0.27 10945.9 (4333'6) Clew A TYPE 2 -407 up to .185T (-40C up to .85.C) (X2116 pursue, minimizing paper output in consideration of the global environment. • ocea�..a aF o.. o44,..00 . ; b a�mlwa . ocells Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 0 a • O • 6 O 117 e O e O 0 0 w .0 1NF 12-25 YEAR WARRANTY 9 1 - Optimized installation with HD -Wave technology e 0 SI1LAN / Specifically designed o work with power optimizers / UL1741 SA certified, for CPUC Rule 21 grid complianc / Record -breaking 99% weighted efficienc / Small, lightweight, and easy to install both outdoors or indoors / Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp ! Fixed voltage inverter for longer strings / Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 solaredge.com Built-in module -level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solar •= - . Single Phase Inverter With HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H-US 0050000 -US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS SEXXXXH-XXXXXBXX4 WI1H PART NU NIBER OUTPUT Rated AC Powe0O ut MI 3000 3800 @ 2404 5000 6000 Ed 2404 766 CA 3300 Ca 206V 5000 208V I 10000 11400 (47 240V I 0 VA 10000 @ 208V Maximum AC Power Output 3000 3800 ®2404 5000 600010 240V I 7600 3300 @ 2004 500010 2084 10000 11400 ®2404 I VA 100001@ 2084 AC Output Voltage Mln,-Nom-Max. (211- 240 - 264) V 1 Vac AC Output Voltage Min. -Nom -Max. (103 - 200 -229) • .l / - i Vac AC Frequency (Nominal) 59.3-60-60.99 Hz Maximum Continuous Output Current 0240V 12.5 16 21 25 i 32 42 473 A Maximum Continuous Output Current 1@2084 16 - 24 46.5 A Power Factor 1, Adjustable- 0,85: to 095 GFDI Threshold 1 A Ut0ty Monitoring. (standing Protect -10R Country Confx_wrable Thresholds Yes INPUT Mazimuth DC power ©243V 4650 5900. 7750 9300 I 11900 15500 ; 17650 1 W Maximum DC Power 65208,) - 5100 - _ 7750 1 - 15500 W TrensformeMeat Ungrounded Its Maximum Input Voltage 480 V& Nominal DC Input Voltage 380 400 Vic Maximum Input Current ®240Na 8.5 1 10.5 13.5 I 16.5 20 27 1 30.5 Adc Maximum Input Current 592084'' - 9 L 13.5 _ _ - 1 27 Adc I Adc Max. Input Short Orro8 Current 45 Reverse -Polarity Protection Yes Ground -Fault Isolation Detection 60010. sen.itialy Maximum Inverter Efficiency 99 992 _ _ 991240V % 98.5 @ 208V CEC Weighted Efficiency 99 Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES _ Connection _ Supported Communication Interfaces RS465, Ethernet, 21gBee (optional), CelluLar (optional) Revenue Grade Metering, ANSI 012.20 Consumption metering Inverter Commissioning Opppnolw With the SetApp mahile application using Built-in Wi-Fi Access Point for Local Rapid Shutdown - NEC 2014. NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 5A, 51.16990, CSA 0222, Canadian AFC( according to T.I.L. M-07 Grid Connection Standards IEEE1547. Rule 21, Rule 14 MO Emssions P77 Part 15 Class 6 INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1" Maximum / 14-6 AWG I 1" Maximum /14-4 AWG C Input Conduit Size/0 of5tdngs/ 1"Maximum /1-2 strings/14-6 AWG 11"Maximum/1-3 strings/14-6 AWG Dimensions with Safety Switch (F3WeD) 172 o14,6 o6:8 /450 x3708174 213 114.61 7.3/5401 370 8 105 ,17/mm Weight with Safety Switch 22/10 1 251111.4 • 26.2/11.9 - 38.8/17,6 Ib/59 None o35 _ <50 7 406 I 0/-C consumption meteri:g, current hansrwmers slwNd be Cooling Natural Convection Operating Temperature Range Protection Rating wee 8Y lima as inp4 -US 9SNC4, iI -20.20 de-ra i g inMmvaon the som0g. 8190°mrannn thii• respaet•••••e•oa• -40 to+140/-40 to +8011 NEMA 4% (Inverter with Safety Switch) (0 For olner regional semngs please contact (010,0dge (A A higher current salve may be used; de inverter (0 Inverter ordered wit,sepa u.0 de Mew PR : 100H (4) Full pw.n up lo at least 570 /t2YF: for pacer 050wfeg. 08+534946880,58M1bmr na SMARM, ....enures mannered her. art trademarks of ahem to 6.040es stared we per bon Production and Cmsuml n Mere PM: 51,041-55000N14. For refer to: MVrs/e•e•ee 1aredge.c0NsileYtlelaup/files/...rgereNlederalvg-rrote-noedf 10 SOMME No too,* cr mpMnndoaermr6 al Sole.* wave)Wlea Inc 1•7020,1,1110 MM. Sub). In charge without nat.. Power Optimizer For Residential Installations 5440 / 5500 / 5500B 25 YEAR ,WARRANTY Enabling PV power optimization Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module -level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) •Fuconww0Oraroinrem.,eoeer.raemv ennon solaredge.com at the module level 0 0 70 1 Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading T Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization 1 Compatible with bifacial PV modules solar ' I Power Optimizer For Residential Installations 5440 / 5500 / 55008 55006 01415 INPUT Rated Irous DC Power. Absolute Maximum Input VMage NOU MPPT Operating Range Maximum Short [bait Current 051 of Connected PVMadule Madmum Efficiency Welped Efficiency Overvoltage Cativoy OUTPUT DURING OPERTION Madmum Output Current Maximum Duput Voltage OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Solent. OulputVdtax.Per Power Optimizer y' 1x0.1 STANDARD COMPLIANCEI5 EMC FCC Part 15 Class B.1E061000-6-2, 6[61000-6-3. CISPRI1, EN -55011 Satety 1E052109.1 (class d Wry), UL1741 Material OLDS V-0, UV Re515lam RoHS Fire Safely INSTALLATION SPECIFICATIONS 14.5 60 B-60 993 00,6 5 25-105 Vol Vdc Ark 15 60 80 1 00* VOE-012{ 2108.]12:2018.12 m Alms em voltage Dimensions (5* a L y H) weight (including cables) Input Connector Input Wire Length Output Connector Output Wire Leryth Operating Temperature eenrrm Protection Pad Relative Humldky 0-100 1295155x30 1000 155x45 Vdc 655 MC4' 4r Mc4 11123, (-1 0.10 -40 W 085 1668 •c 111 Rated power tithe module et slC all era eased the Poser (Veneer Rated input DC Power. Hodges wish W m.5% pour tolerance are akosod. (2r Rs -Mails stout CE nmpliance, owe 1rlarann MrnnMmiw-r7. 131 Fa innerCOmecta types Arose contact 5df8d3e. NI For ambientnmperaWms ab0.e.amC paw. de-rermg is appal. eerrmyour0 0,.raTmerewhwe O1.40000+brrdNo@ for Ueta6 Mlmmum string length 544E 5500 (Pourer Optimizers) SSOOB MermurnS5ir5Lle 11(Power Opnmi:ers) Madmum Continuous Power per String Madmum Allowed Connected Power per Suing Denied only when the paveartrermce Seem..' 95 d m5 than 08821 25 5700 See* Seem' Parallel SIru5)s of Different Lear the or Orientations_I_,_ 151111s rho allowed to nh 5 -snip end P-u+ks Power°OCmians In new 6st.h5wn 10 If die weeoe7s rated Ac saver madmumnoninat power Per ming then to maximum pane per sting ML beebkm reed, kinieencl. menmuminp2OC parer. Refer.easiutahaizSgaie2goakziaaandtiots, Yes 13500 I •45mm MMOS ur me.um.a Irrrm..na.mar0c1.10nmew•owns.One 10..10.20,2 osmomsu,o S.A. 0 awPr Wawa row. 612 SI1 vaMn.nns'ereMe dlern• sasoYrraparedoomyu sc 15000 CC RoHS KUP-L-TAP® (IPC) Insulation Piercing (Dual Rated) st• • rupi.Tn6RllmuYOmp,md”pcmnador. • Body Y molded from WW1. ',Wien, 9m6T.d nybn. • VC 466311190• C LMtl eM Y CSA C.NXetl. • For me MM...I conductor pen ll or • Compact &don. • 18 Rated capper contact YM and p•4AW war,Cain lWnan. • Removable end 6033. • OW Rated for Capper end auNnum CaMuda,. • ULFlIe 66207 ,654/06 2 0/04 AWG 6-146600 600 1/2 12 0]83669692602 Grounding Connectors TYPE: 11 Lay -In Connector CMC® LI-S ground connectors are manufactured from high strength 6061-T6 aluminum alloy to insure both maximum strength and conductivity. They are dual rated for both copper and aluminum conductors and are eiectro tin plated to provide low contact resistance and protection against corrosion. They are designed for use on conduit grounding bushings. The open-faced design allows the installer to quickly lay -in the grounding conductor as a Jumper to multiple conduits with no break in the ground conductor. 90°C RATING (4868 LISTED) — Catalog Number FigNoNo- Cond. Range AWG Stud Stu• Dimensions, Inches N I W L L1 -562S 1l 9 - 24 0.2a 0.78 1 :036 i,07 U -112S 1. 1/0 - 14 0.27 1.17 0.6 1.5 11-2005 2 3/0 - 6 0.33 1.56 0.8 2 11.2535 2 250 - 6 0.33 1.79 1 0.8 2.2 1/4-20 LINE • 28 x.53 OP REF.' 1006.015 (5.055.101 .1906.010 (3.93.#.251 •-----1.070}.015 — —� (27.194381 0.220 711R11 TAP WITHIN .072" MAX OF BOTTOM Of W(REWA5. 00 NOT 06110 PAST WIREWAY. .3753.010 (9.530.251 .1076.010 (4.75}.25) .150* .006 (3.01.6 .16) .786* .010 I.19.96* .15J *et" IVart '"'" 000494353 1-1/4'18 X.625 LG.5T41NLE55 STEEL 510700 SCREW C.00201027 (2 REAM) ASSEMBLE SCREW 531601 TO 80TTOM CMC 9-311 L1-50-5 CU9AL 613 14ARNING I MARKING 2 ]')141$317 TIN PIXIE Uls-Oz IMMIS 9130112215111212 ae..- .vr tO.pn••e0en p..rM.n AML 11117/2009 SIHT 1 0 1 LAY IN LUG 000601011 6061-T6 ALUMINUM o•.,or 11-50-5 2.25)1 CROSS REFERENCE i - 7 a CLICK INSTALLATION GUIDE CLICKFIT rpIAON DAM 0.1101 ramoa:vu EcoFasten ��• i:• .! �Ilrr. By Installers. The UL 2703 listed ClickFit is one of the fastest installing rail -based systems in the industry. Thanks to its Click -In Rail assembly, the rails can be connected to any of EcoFasten's composition shingle, tile and metal roof mounts in seconds without the need for fasteners or tools. The ClickFit system is made of robust materials, such as aluminum and coated steel, to ensure resistance to corrosion and longevity. ClickFit is tested in extreme weather, wind, fire, and snow conditions. FEATURES • Tool and fastener free rail attachment • Fully integrated bonding • Click -on Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments �t LL LL- z W co U) w LL PAGE 02 CLICK INSTALLATION GUIDE IVIV61,01. 01111 01111/11 EcoFasten Installers. Installers. By Installers. RATINGS Fire Rating*• Class A System Fre Ratlng Max System Voltage 1500 VDC Max Fuse Rating 30A Certification Conforms to UL STD 2703 Warranty 20 Year Material and Workmanship UL 2703 Markings Product listing label is located on the rail end -caps Roof Pitch 2:12 -12U 2 UL 2703 Allowable Design Load Rating 10 psf downward, 5 psf upward, and 5 psf lateral Max Module Size 25.6 sqft Module Orientation Portrait or Landscape Multiple use Rated Components (Position Independent) MW Clamp, MLPE Clip, and MLPE Bracket **Class A System fire rating with Type 1 8,2 PV modules. Any module to -roof gap is permitted, with no skirt required. This rating is applicable with any roof attachment. UL 2703 MARKING EXAMPLE: EcoFasten CLICKFIT SYSTEM Us Intertek XXXXXXX TORQUE SPECIFICATIONS Component Torque (in -lb) Notes Lag Screw N/A Fully Seat. Use visual indicator of the black EPOM ring around the bonded washer for torquing. Mid -Clamp 144 End -Clamp % Rail Clicker Leveling Bolt 142 Pre -torqued upon delivery. Applies to Tile Hook and L.Foot/Cllcker Hook Height Bolt N/A Lightly damp hook to bush with top of next tile row Ground Lug N/A Refer to specific ground lug manufacturer's installation manual MLPE Clfp 144 MLPE Mount 144 cn CD z a PAGE 06 Site Info / Photo of Front of Home (from across the street) Clifton Moniz Loc: 41.7391, -70.1412 Page 7 of 32 Report Created: 08/10/2023 Site Info / Photos: Trees to be trimmed / removed Site Info / Photos: Trees to be trimmed / removed Clifton Moniz Loc: 41.739, -70.1409 Site Info / Photos: Trees to be trimmed / removed Clifton Moniz Loc: 41.7392, -70.141 Clifton Moniz Loc: 41.7389, -70.1409 Site Info / Photos: Trees to be trimmed / removed Clifton Moniz Loc: 41.7392, -70.141 Page 24 of 32 Report Created: 08/10/2023 Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US O t7 0 • 9 e 0 0 1111 0 O plax110i -!Q. - e O 12-25 YEAR WARRANTY Optimized installation with HD -Wave technology / Specifically designed o work with power optimizers Record -breaking 99% weighted efficient Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings 1 Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 solaredge.com • 0 0 SJ3IILAN UL1741 SA certified, for CPUC Rule 21 grid compliant / Small, lightweight and easy to install both outdoors or indoors 1 Built-in module -level monitoring / Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) solar Mr ® Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US MODEL NUMBER SE3000H-US SE3800H US SE5000H US SE6000H US SE7600H US SE10000H-US SE11400H-US APRI. !CABLE 10 INVERTERS WITH PAR1 NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output Maximum AC Power Output AC Output Voltage Min -Nom, -Max. (211 - 240 - 2641 AC Output Voltage Min; Nom: Max, (183 .208 - 2291 AC Frequency (Nominal) _a __ Maximum Conhmuous Ou_lpul Current @2409 Maximum Continuous Output _Cgrrent_012030 Power Factor GFDI Threshold Utility Monitoring, Islanding Protection, Country Configurable Thresholds INPUT Maximum DC Power @2409 Maximum DC Power 6E208V Transformer -less, Ungrounded Maximum Input Votage Nominal DC Input Voltage Maximum Input Current @24001 Maximum Input Current @20600'' Max input Short Circuit Current Reverse -Polarity Protection Ground -Fault Isolation Detectron Maximum Inverter Efficiency 3000 3800.240V 3300 @ 208V 3800 .. 4 38D @ @ 240V 3300 @ 2089 J J 3000 125 16 16 5000 5000 J 21 6000 @ 240V 5000 @ 208V 6000 @ 2400 5000 @ 2089 _ 59.3.60-60.5- 25 7600 10000 11400 @ 240V 10000 @ 2039, 7600 10000 11400 @ 2403 10000 @ 208V VA 32 24 1 - 1, Adjustable - 085 to 0E5 Yes 9,6 42 47.5 48,5 Vac Vac Hi_ A _ A A 4650 5900 7750 5100 CEC Weighted Efficiency Nighttime Power Consumption ADDITIONAL FEATURES Supported Communrcation Interfaces Revenue Grade Metering, ANSI C12.20 Consumption metering Inverter Commissioning Rapid Shutdown - NEC 2014. NEC 2017 and NEC 2020, 690.12 STANDARD COMPLIANCE Safely Grid Connection Standards Emissions INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range DC Inlet Conduit Are / 4 of Strings /J AWG Range Dimensions with Safety Switch (9x0010). Weight with Safety Switch Noise Cooling Operating Temperature Range Protection Rating 05 99 9300 11800 15500 7750 5Es 480 380 10.5 135 16.5 17650 W 15500 w 400 27 Oct INt 305 Ark 27 1 Arc Ado 13.5 45 Yes 60060 Sensitivity 99.2 99 996 98.51 < 2.5 240V % 2080 W RS485, Ethernet. ZgBee (op onall, Cellular (optional) Optional... With the SetApp mobile application using BL.M!n Wi-Fi Access Point for Incal ComKction Automatic Rapid Shutdown upon AC Grid Disconnect UL1741, UL1741 SA. 3L16999, CSA C22.2, Canadian AFC! according to LLL. M-07 1E6E1547, Rule 21, Rule 14 (90 FCC Part 15 Class B 1" Maximum / 14-6 AWG 1" Maximum /14-4 AWG 1" Maximum / 1-2 strings /14-6 AWG 11" Maximum / 1-3 strings / 14-6 AWG 22/10 17.7,14,6x6.8 /4501 370 1174 25.1/114 1 < 25 26.2/11.9 Natural Convection -40 m.140/-40 to .60' N(MA 40 (Inverter with Safety Switch) I 21.3 x14.6 x 73/ 540 x370 x185 38.8/17,6 <50 m/m lb/kg 40A 'F /'C 10 For ohr fonelxt0ng, please contact SolarEdge upport 21 A higher anml Forte maybe men: Me merle, w4P limit its Input anentlo the values stated 11) inverter rail Remue Grade Meter P/N• 5 lneH-USO50ONC4 'owner with Revenue Grade Produce, and Clnsump MeterPM: SEaoMI-05000MM.For <onsumptxm metering, anent transformers should be arrived separably. 5EAC10750-200NA-20or SEAC10750-a00NA-20. 20 urns per box pal Full power up to at least 50'C /122.F. for power de -rating e,lurmanonsefer to: Nrps1Awvw.sdaetge cwNmemrle1a imPe159etermeraluredetemq-noo-nandl e Sah,E4p 7asMd0he Irc all rpm.ruv,.d S0L4J0GF,theY,.,edge loan OlUIUDnSOIMeeGF an0ahnurb snel0<r.lM aromas NSd0,4g. 5Mnlo5Yy IrcM em.rtr.amemeenmaeeherein an tr,eu.. of iher nspectireamen.Dale12nm5A11/ENc NMI.mc;<n tot. wieren „mx.. Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module -level / Specifically designed to work with SolarEdge inverters ! Up to 25% more energy / Superior efficiency (99.5%) ! Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading / Flexible system design for maximum space utilization solaredge.com d Fast installation with a single bolt 1dO 2l3MOd N m 6 Next generation maintenance with module - level monitoring S Meets NEC requirements for arc fault protection (AFC[) and Photovoltaic Rapid Shutdown System (PVRSS) A Module -level voltage shutdown for installer and firefighter safety solar0 / Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 0!170 P 3.10 P401 P405 P.1/15 P505 Optimizernlodtl 0320 Ilea INgh (for hlghrr 9.00 (lea high 1•; tinil nlnJule Om b0 trill tichmm (tot 72 R GO Or high [fir high (fnr h1911, ItnsvPr 6O,Intl 72 96 Cell I1O•x s'r 1011.194 vnit.u4 current rs2n,p.inlullty) mu41u1r51 60-rrll 0.11 modules` And 72 rill 1171011 PS modules) modules() nunlul",) nuafulosl ,nodule* INPUT Rifted input DC Rowel. 320 350 370 400 • Absolute Muir.. lrrput%iag= 4a 60 60 (%0 at la vtemper...) 405 485 505 60 125. .- .. _ 939° T W 16)0 44771 Operating Range 0-4a 8-60 8-80 0-60 1 12.5-105 12.5.93 Mk Maximum Short ClrsuitCurrenl tl 10.1 O.) 11.75 11 14 Ado Maxmum DC Input Current 175 12.5 1465 12.5 17.5 Adc Maximum Elkienty Weghled Efficiency 1j1 99.5 - _ 98.9 985 % 0.11190830 Ca413.ry 1 11 OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maxmum Output Current "�I 15 Ado Maximum OulprR%ltege I 60 65 We OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 5arrb Output Voltage per Rower 0111 1.1er 1 a 01 We _ _ STANDARD COMPLIANCE . - EMC FCC Re 915 Class 9, 1E061000 -6-21E061000-0-3 Safely IEC62109.1(clas 8 safety), 111741 Material 44940-0, W Re0da0 RgiS 168 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 1 ""c Compatible inverters _1 `^ All SolarEd9e 5rngk Phase and Three Phase trNvters Olmensions(W. Lx 11) '129xt53z33.51129x153 x235 1291162059/ mm 129.153127.5/5.1,6 x 1.1 129.159049.5/5.1x6.301.9 1 /5.1.6x1.3 I /3.1x62 11fi 5.1 x6A x 2.3 /in Weight 0ncldding 0414.1 630/1.4 • 750/17 655/1.5 845/1.9 1364/23 9r/84 Input Connector MC4P T Sxgle or dual I r"` ,,„.4. MC4F Input Whe length 016/0.52 1/0,52Q1fixpr092.95° 0.16/0.52 n1/ ft Output Wire Type / Connecml Double Insulated / MC4 Output Wire Length 0.9/2.95 1.2/3.9 m/R Operating Temperature 6209.w -40-485/-40-.185 -C/-F - _ _ _ _ Protection Rating IP68/NEMA4P Relative Humidity 0 -100 % 1q Rated p.rer or the module at FTC 8a 001mimed Ne opl.p441la,M input IXPowY. M0Mdea with up m+59s power telew,xeee altwed (2) NEC 207 mann mm 0741 wltre be =mom Pan 90V 131For &Me contector types pow axeaet 5o W rdg? R For 04 ,neion 14 p. iII0 ox necuon anon mrdide1 u,2P4R5-ONMOMRM. In the ease d an odd rmONRo W ,,Mules .one sting itta1litg no. P4R5 tluel...en more 1Vmodule . 021n =mecum a male module seal the unused Input connectors WMtv.app5N per duos (5)1.^9.,,^1,.., 9 fe glhore 8..894 for we. For 09m 1pmwrt *Nth o lee P101-mtm, OFm ambent in:mem.stove •85K/•11151pox&de.retng Is app.. Rifle to Neer Op,irnyers Temperature Do-Raug Tema. tsum Fa more deeas 1•V ',..1,..9 11 , , U. ¢- / :,1r d Snl,uFdnc i i, ..-�.. 1 .. , _i):.11 p3252 PMQ 299Q MIOnum Stray Love PAX P4ir a 10 ttxnec.d 18 - (Power Oplin..0.1 . POS. 0495, P50 6 8 14 Wainhrm S.41g Length rawer 0pllml2ns) 25 ' 25 500 - 5700(6000.4 Maximum Pewerper Sting 5E7600 -11S -5E11400- 4151 5250 6001)" 12750'' I W Parallel Shilgl Of Dtfferenttengths or Orhagation5 1Fs _ (n 80 9,14 d mig sing 'Iva Me. 20041/ wedarMOamlrySit52defe49049riywing 29801 nle.n riot tamed mmw040519485/1105WM P321,1/1'341.3/0/P,04,01 in one48289 M A erg oath 1mi8Mn 30',Ormwrs don not meet NEC rapid 0419*, requiemertsafery whet,.,Yr be &ow the 3w requiem.. PO Fe 20495fid RisSlaw! to instal ,p l9 &S0U1 Pe sang Wien Me mairem poweren1owoe 4(x100 each sting is Wow PI). ni/HH grit &a911,0m steal i9m 15960w per mi gxhen Me 18.02 n pony deee4e be1ieen eachmet, is MOW pSci.dgeral a�.m4d SOLV.C..s4F,.at. ore sr. ..d.9w.P.d .,. r ascawtra o mtmahimem.a.etm.More.Ir�wn..axe.papplrawlp5 034 ,.041.54 1.111,g1„110.mem a °mow RoHS intern* KUP-L-TAPIS ([PC) Insulation Piercing (Dual Rated) • Kw.L-r.pMl .6A6lIon dmang = mem,. • Body le Molded 50m lough, realism •!s441149 nylon. • Ul486N690, Listed mid Is GSA canoes. • Form *M enema consuls Caw B or • Comp.0leelpn. • Tin Phledcapp.rm1W]t.e• end prt6 1.1131FvnlWp7m•. • Remove. end tete. • D,m6R.t462Copper .,,d Alnmxn:mcae.omr. • 10. Fie 26207 190,20-6 2 410,1 AW0 st. 6-14 AM 600 12 12 0783669532692 970 mown 4690, Grounding Connectors TYPE: LI Lay -In Connector CMC® LI-S ground connectors are manufactured from high strength 6061-T6 aluminum alloy to insure both maximum strength and conductivity. They are dual rated for both copper and aluminum conductors and are electro tin plated to provide low contact resistance and protection against corrosion. They are designed for use an conduit grounding bushings. The open-faced design allows the installer to quickly lay -in the grounding conductor as a jumper to multiple conduits with no break In the ground conductor. 80041 RATING (4868 LISTED) Catalog Pip. No. Number Cond. Rang• STe1d size* AWG 0 mansian•. Inches N 4. 1r1 O.RZ _ 0.70 070 1 02 U-1125 I 1 1/0 - 14 0.27 1 1.17 1. 0.6 1.5 2 LI-2005 2 3/0 - 6 0.33 1.56 0.8 U-2525 2 250 - 6 0.33 1.79 0.6 2.2 1/4-20Lair - 263.53 OP REF. t .2003.015 (5,003.2201 MARKING 2— QM)(4.17] 5 /"'55.220 THRU TAPWm11M .07r MAX Cf 1/ 80TTOM OF W IAE.YAY. 00 MOT DRILL PAST WIREWAY. 1111111 1 111 111111 + III .3750 .010 (9.533.251 .1073.010 [4.755.251 .1905.010 (4.835.25] 1+---� 1.070 0 X115 (27.183,3B1 —MARKIHG]1 .1505 005 [3.813.151 .970..- �I11.94 655k.005 10.645.13] 006494303 _ MTNp. I—l/9ae x.e7s LG. sralMLEss STEEL SLOTE0 SCREW 000201027 (1 REO'D) ASSEMBLE SCREW SNUB TO 807506 CMC U-50.5 MA551HG 1 5u 4-14 0529AL MARK110_1 F1Ni5N; TTH PLATE CMS -02, roe d2C 11/17/2009 MKT Kt 1 o 1 o. LAY IN LUG 050001011 6061-T6 ALUMINUM U-50-$ 2.25X oa{ A CROS5 6ff91FNCE r - CLICK INSTALLATION GUIDE CLICKFIT IllY6101 DAVE Of tint *EcoFasten EcoFasten By Installers. The UL 2703 listed ClickFit is one of the fastest installing rail -based systems in the industry. Thanks to its Click -In Rail assembly, the rails can be connected to any of EcoFasten's composition shingle, tile and metal roof mounts in seconds without the need for fasteners or tools. The CIIckFit system is made of robust materials, such as aluminum and coated steel, to ensure resistance to corrosion and longevity. ClickFit is tested in extreme weather, wind, fire, and snow conditions. FEATURES • Tool and fastener free rail attachment • Fully integrated bonding • Click -on Mid & End Clamps • Compatible with a variety of EcoFasten roof attachments cr EA. W co r PAGE 02 CLICK -I INSTALLATION GUIDE RATINGS Fire Rating" Class A System Fire Rating Max System Voltage 1500VDC Max Fuse Rating 30A Certification Conforms to UL STD 2703 Warranty 20 Year Material and Workmanship UL 2703 Markings Product listing label Is located on the rall end -caps RODE Pitch 2:12 -12:12 UL 2703 Allowable Design Load Rating 10 psf downward, 5 psf upward, and 5 psf lateral ___....: Max Module Size 25.6 sqft Module Orientation Portrait or Landscape Multiple use Rated Components (Position Independent) MId Clamp, MLPE Clip, and MLPE Bracket e IQa EcoFasten , Installer>. By Installers **Class A System fire rating with Type 1 & 2 PV modules. Any module to -roof gap is permitted, with no skirt required. This rating is applicable with any roof attachment. UL 2703 MARKING EXAMPLE: EcoFasten .. bSUEC . . CLICKFIT SYSTEM Intertek XXXXXXX TORQUE SPECIFICATIONS Component Lag Strew Torque (in -lb) N/A Notes Fully Seat. Use visual indicator of the black EPDM ring around the bonded washer for torquing. MId-Clamp 144 End -Clamp 96 Rail Clicker Leveling Bolt 142 Pre -torqued upon delivery. Applies to Tile Hook and L-Foot/Cllcker Hook Height Bolt N/A Lightly clamp hook to flush with top of next tile row Ground Lug N/A Refer to specific ground lug manufacturers installation manual MLPE Clip 144 MLPE Mount 144 Ns cn PAGE 06