Loading...
HomeMy Public PortalAbout20140822 Trane Submittal.pdf Prepared For: Ralph Harrison MJ Wood Date: August 22, 2014 Job Name: Tybee Island YMCA Replacement Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 2 Packaged Heat Pump Units (Dedicated) Eric Igel Trane 3609 Ogeechee Blvd., Suite A Savannah, GA 31405 Phone: (912) 965-0313 Cell: Fax: (912) 965-0314 The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Submittal J:\JOBS\1135\23550\2\Submittal 8-22-14.doc Table Of Contents Product Summary .......................................................................................................................... 1 Packaged Heat Pump Units (Dedicated) (Item A1) ..................................................................... 3 Tag Data ................................................................................................................................................... 3 Product Data ............................................................................................................................................ 3 Mechanical Specifications ........................................................................................................................ 4 Unit Dimensions ....................................................................................................................................... 6 Weight, Clearance & Rigging Diagram ..................................................................................................... 8 Accessory ............................................................................................................................................... 10 Field Installed Options - Part/Order Number Summary ........................................................... 11 Packaged Heat Pump Units (Dedicated) ................................................................................................ 11 Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 3 of 11 Tag Data - Packaged Heat Pump Units (Dedicated) (Qty: 2) Item Tag(s) Qty Description Model Number A1 No Tag 2 20 Ton Heat Pump Pkg WSH240E3R0A--000200000000000000000000000 Product Data - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 Heatpump Standard efficiency Horizontal 20 Ton 208-230/60/3 Reliatel Epoxy coated condenser coil 0-100% Economizer, dry bulb control (Fld) 54 kW electric heater 3 ph (Fld) Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 4 of 11 Mechanical Specifications - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 General - Unit The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with AHRI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal, service panels shall have lifting handles and no more than three screws to remove. All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2", 1.0 lb pound density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2", 1.0 lb pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage Filters Two inch standard filters shall be factory supplied on all units. Optional two inch pleated media filters shall be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 200 psig and pressure tested to 450 psig. All dual compressor units shall have intermingled evaporator coils. Sloped condensate drain pans are standard. Patent-pending 1+1+1 condenser coils, permanently gapped for easy cleaning. RT-PRC028-EN 119 Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. Oversized motors shall be available for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Controls (R-410A) Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 5 of 11 control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control. When the discharge temperature rises above the protection limit, the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage. Accessory - Electric Heaters Electric heat modules shall be available for installation within the basic unit. Electric heater elements shall be constructed of heavy-duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and 600 volt. Staging shall be achieved through ReliaTel. Each heater package shall have automatically reset high limit control operating through heating element contactors. All heaters shall be individually fused from the factory, where required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide single-point connection. Electric heat modules shall be UL listed or CSA certified. If ordering the Through the Base Electrical option with an Electric Heater, the heater must be factory installed. 122 RT-PRC028-EN Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 6 of 11 Unit Dimensions - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 46 7/16" 27 9/16" 3 15/16" 2"24 1/16"26 1/2" HORIZONTAL CONDENSATE DRAIN CONNECTION 1.0 (25.4MM) NPT END PANEL 5 9/16" FILTER ACCESS DOOR 121 11/16" 64 1/8" 6 7/16" 56" SINGLE POINT POWER ENTRY 2" DIA. HOLE (UNIT POWER WIRE) 84 3/16" 32 11/16" 1" 8 15/16" 2 11/16" 7/8" DIA. HOLE (UNIT CONTROL WIRE) SUPPLY RETURN PACKAGED HEAT PUMP - HORIZONTAL ISOMETRIC DRAWING PACKAGED HEAT PUMP -HORIZONTAL HORIZONTAL CONDENSATE DRAIN AND FILTER ACCESS SIDE VIEWAIR FLOW VIEW NOTES: 1. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 7 of 11 Unit Dimensions - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 WSH240E (20.0) 187-253 208 230 60 3 9.7 116.0/116.0 150.0/150.0 150.0150.0 40.5/54.0 2 257.0/246.0 300.0/250.0 300.0/250.0 2 10.4 3 39.1 267 2 1.0 1,125 1 5.0 14.4 1 5.0 3,450 3 16.7 109.8 Throwaway Yes 12 20"x20"x2" R410 20.0 lb / 20.7 lb Type: Factory Charge Circuit #1 / 2: Number: Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: Minimum Circuit Ampacity: Maximum Fuse Size: Maximum (HACR) Circuit Breaker: Minimum Circuit Ampacity: Maximum Fuse Size: Maximum (HACR) Circuit Breaker: Accessory Oversized Motor Accessory Oversized Motor Accessory Oversized Motor with Heat REFRIGERANT Standard Motor Standard Oversized Motor POWER EXHAUST ACCESSORY Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: NOTES: Number: Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: (Field Installed Power Exhaust) Type Furnished: Number: Recommended Size: Number: Horsepower: Motor Speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: FILTERS EER: Number: Horsepower: Phase: Rated Load Amps: Locked Rotor Amps: COMPRESSOR INDOOR MOTOR Standard Motor with Heat Rating - kW Stage Minimum Circuit Ampacity: Maximum Fuse Size: Maximum (HACR) Circuit Breaker: HEATER Unit Operating Voltage Range: Unit Primary Voltage: Unit Secondary Voltage: Unit Hertz: Unit Phase: Model (Tons): GENERAL Minimum Circuit Ampacity: Maximum Fuse Size: Maximum (HACR) Circuit Breaker: Minimum Circuit Ampacity: Maximum Fuse Size: Maximum (HACR) Circuit Breaker: Standard Oversized Motor with Heat Number: Horsepower: Motor speed (RPM): Phase: Full Load Amps: Locked Rotor Amps: OUTDOOR MOTOR Minimum Circuit Ampacity: Maximum Fuse Size: Maximum (HACR) Circuit Breaker: ELECTRICAL / GENERAL DATA Standard Oversized Motor Standard Motor Circuit #1 / 2 Circuit #1 / 2 (7) (6) (4) (1) (3) (4) (6) (4) (6)(6) (1) (3) (5) (8) (9) (8) (6)(6) (2) 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value does not include Heater. 5. Value include Standard Motor. 6. Value include Oversized Motor 7. EER is rated at AHRI conditions and in accordance with DOE test procedures. 8. For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps. 9. HP for each compressor. Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 8 of 11 Weight, Clearance & Rigging Diagram - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 CLEARANCE 18" (457.2mm) CLEARANCE 38" (965.2mm) CLEARANCE 60" (1524mm) CLEARANCE 48" (1249.2mm) CLEARANCE FROM TOP OF UNIT 72" (1828.8mm) SUPPLY RETURN PACKAGED HEAT PUMP - HORIZONTAL CLEARANCE Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 9 of 11 Weight, Clearance & Rigging Diagram - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 2566.0 lb 2107.0 lb 674.0 lb 485.0 lb 400.0 lb 590.0 lb 57"35" 40.0 lb F E CORNER WEIGHT B C A D RIGGING AND CENTER OF GRAVITY TOOL-LESS HAIL GUARD (FIOPS) OVERSIZED MOTOR POWER EXHAUST HIGH STATIC DRIVE MANUAL OUTSIDE AIR DAMPER THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) ECONOMIZER / MOTORIZED OUTSIDE AIR DAMPER ROOF CURB HINGED DOORS (FIOPS) ACCESSORY BASE UNIT WEIGHTS SHIPPING CENTER OF GRAVITIYCORNER WEIGHTS NET (E) LENGHT NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT OF OPTION/ACCESSORIES ADD 5 LBS TO NET WEIGHT. 3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN ORDERING FACTORY INSTALLED ACCESSORIES. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS. 5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED OPTION (ECONOMIZER AND/OR OVERSIZED MOTOR OR FIOP/ACCESSORY WEIGHT MUST BE ADDED. (F) WIDTH INSTALLED ACCESSORIES NET WEIGHT DATA WEIGHTS HEATER DB A C SMOKE DETECTORS Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 10 of 11 Accessory - Packaged Heat Pump Units (Dedicated) Item: A1 Qty: 2 1 9 1 /2 " 6 4 3 /4 " H O R I Z O N T A L - E C O N O M I Z E R H O O D A C C E S S O R Y D R A W I N G O U T S I D E A I R H O O D (E C O N O M I Z E R D A M P E R ) E N D P A N E L O U T S I D E A I R P A N E L / A C T U A T O R A C C E S S P A N E LFILTER A C C E S S D O O R Tybee Island YMCA Replacement August 22, 2014 FLD = Furnished by Trane U.S. Inc. / Installed by Others Equipment Submittal Page 11 of 11 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - Packaged Heat Pump Units (Dedicated) Item Tag(s) Qty Description Model Number A1 No Tag 2 20 Ton Heat Pump Pkg WSH240E3R0A--0 002000000000000 00000000000 Field Installed Option Description Part/Ordering Number 54 kW electric heater 3 ph AYHHTRN354A 0-100% Economizer, dry bulb control BAYECON092B