HomeMy Public PortalAbout20140822 Trane Submittal.pdf
Prepared For:
Ralph Harrison
MJ Wood
Date: August 22, 2014
Job Name:
Tybee Island YMCA Replacement
Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval.
Product Summary
Qty Product
2 Packaged Heat Pump Units (Dedicated)
Eric Igel
Trane
3609 Ogeechee Blvd., Suite A
Savannah, GA 31405
Phone: (912) 965-0313
Cell:
Fax: (912) 965-0314
The attached information describes the equipment we propose to
furnish for this project, and is submitted for your approval.
Submittal
J:\JOBS\1135\23550\2\Submittal 8-22-14.doc
Table Of Contents
Product Summary .......................................................................................................................... 1
Packaged Heat Pump Units (Dedicated) (Item A1) ..................................................................... 3
Tag Data ................................................................................................................................................... 3
Product Data ............................................................................................................................................ 3
Mechanical Specifications ........................................................................................................................ 4
Unit Dimensions ....................................................................................................................................... 6
Weight, Clearance & Rigging Diagram ..................................................................................................... 8
Accessory ............................................................................................................................................... 10
Field Installed Options - Part/Order Number Summary ........................................................... 11
Packaged Heat Pump Units (Dedicated) ................................................................................................ 11
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 3 of 11
Tag Data - Packaged Heat Pump Units (Dedicated) (Qty: 2)
Item Tag(s) Qty Description Model Number
A1 No Tag 2 20 Ton Heat Pump Pkg WSH240E3R0A--000200000000000000000000000
Product Data - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
Heatpump
Standard efficiency
Horizontal
20 Ton
208-230/60/3
Reliatel
Epoxy coated condenser coil
0-100% Economizer, dry bulb control (Fld)
54 kW electric heater 3 ph (Fld)
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 4 of 11
Mechanical Specifications - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
General - Unit
The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 115°F and 0°F in
cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with AHRI testing
procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested
to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to
the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in
accordance to UL 1995/C 22.2, 236-05 3rd Edition.
Casing
Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned,
phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a
salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the
unit. In order to ensure a water and air tight seal, service panels shall have lifting handles and no more than three screws
to remove. All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2", 1.0 lb pound
density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be
insulated with 1/2", 1.0 lb pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no
penetrations within the perimeter of the curb other than the raised 1 1/8" high supply/return openings to provide an
added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift
and crane lifting.
Unit Top
The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage
Filters
Two inch standard filters shall be factory supplied on all units. Optional two inch pleated media filters shall be available.
Compressors
All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction
gas-cooled and shall have a voltage utilization range of plus or minus 10
percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have
crankcase heaters, phase monitors and low and high pressure control as
standard.
Refrigerant Circuits
Each refrigerant circuit shall have independent fixed orifice or thermostatic expansion devices, service pressure ports,
and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line
driers.
Evaporator and Condenser Coils
Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Coils
shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak
tested to 200 psig and pressure tested to 450 psig. All dual compressor units shall have intermingled evaporator coils.
Sloped condensate drain pans are standard. Patent-pending 1+1+1 condenser coils, permanently gapped for easy
cleaning. RT-PRC028-EN 119
Outdoor Fans
The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge
position. The fan motor(s) shall be permanently lubricated and shall have built-in thermal overload protection.
Indoor Fan
Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall
have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be
thermally protected. Oversized motors shall be available for high static application. All indoor fan motors meet the U.S.
Energy Policy Act of 1992 (EPACT).
Controls (R-410A)
Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power
wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be
provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or
ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 5 of 11
control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building
comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a
higher level of machine protection.
High Pressure Cutout
This option is offered for units that do not have High Pressure cutout as standard.
Discharge Line Thermostat
A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system.
This standard option provides extra protection to the compressors against high discharge temperatures in case of loss
of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge
line thermostat is wired in series with high pressure control. When the discharge temperature rises above the protection
limit, the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature
on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor.
When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that
stage.
Accessory - Electric Heaters
Electric heat modules shall be available for installation within the basic unit. Electric heater elements shall be
constructed of heavy-duty nickel chromium elements internally delta connected for 240 volt, wye connected for 480 and
600 volt. Staging shall be achieved through ReliaTel. Each heater package shall have automatically reset high limit
control operating through heating element contactors. All heaters shall be individually fused from the factory, where
required, and shall meet all NEC and CEC requirements when properly installed. Power assemblies shall provide
single-point connection. Electric heat modules shall be UL listed or CSA certified. If ordering the Through the Base
Electrical option with an Electric Heater, the heater must be factory installed. 122 RT-PRC028-EN
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 6 of 11
Unit Dimensions - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
46 7/16"
27 9/16"
3 15/16"
2"24 1/16"26 1/2"
HORIZONTAL CONDENSATE
DRAIN CONNECTION 1.0
(25.4MM) NPT
END PANEL
5 9/16"
FILTER ACCESS DOOR
121 11/16"
64 1/8"
6 7/16"
56"
SINGLE POINT
POWER ENTRY
2" DIA. HOLE
(UNIT POWER
WIRE)
84 3/16"
32 11/16"
1"
8 15/16"
2 11/16"
7/8" DIA. HOLE
(UNIT CONTROL
WIRE)
SUPPLY RETURN
PACKAGED HEAT PUMP - HORIZONTAL
ISOMETRIC DRAWING
PACKAGED HEAT PUMP -HORIZONTAL HORIZONTAL CONDENSATE DRAIN AND FILTER ACCESS
SIDE VIEWAIR FLOW VIEW
NOTES:
1. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH
INSTALLER DOCUMENTS BEFORE INSTALLATION
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 7 of 11
Unit Dimensions - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
WSH240E (20.0)
187-253
208
230
60
3
9.7
116.0/116.0
150.0/150.0
150.0150.0
40.5/54.0
2
257.0/246.0
300.0/250.0
300.0/250.0
2
10.4
3
39.1
267
2
1.0
1,125
1
5.0
14.4
1
5.0
3,450
3
16.7
109.8
Throwaway
Yes
12
20"x20"x2"
R410
20.0 lb / 20.7 lb
Type:
Factory Charge
Circuit #1 / 2:
Number:
Horsepower:
Motor Speed (RPM):
Phase:
Full Load Amps:
Locked Rotor Amps:
Minimum Circuit Ampacity:
Maximum Fuse Size:
Maximum (HACR) Circuit Breaker:
Minimum Circuit Ampacity:
Maximum Fuse Size:
Maximum (HACR) Circuit Breaker:
Accessory Oversized Motor
Accessory Oversized Motor
Accessory Oversized Motor with Heat
REFRIGERANT
Standard Motor Standard Oversized Motor
POWER EXHAUST ACCESSORY
Horsepower:
Motor Speed (RPM):
Phase:
Full Load Amps:
Locked Rotor Amps:
NOTES:
Number:
Horsepower:
Motor Speed (RPM):
Phase:
Full Load Amps:
Locked Rotor Amps:
(Field Installed Power Exhaust)
Type
Furnished:
Number:
Recommended Size:
Number:
Horsepower:
Motor Speed (RPM):
Phase:
Full Load Amps:
Locked Rotor Amps:
FILTERS
EER:
Number:
Horsepower:
Phase:
Rated Load Amps:
Locked Rotor Amps:
COMPRESSOR
INDOOR MOTOR
Standard Motor with Heat
Rating - kW
Stage
Minimum Circuit Ampacity:
Maximum Fuse Size:
Maximum (HACR) Circuit Breaker:
HEATER
Unit Operating Voltage Range:
Unit Primary Voltage:
Unit Secondary Voltage:
Unit Hertz:
Unit Phase:
Model (Tons):
GENERAL
Minimum Circuit Ampacity:
Maximum Fuse Size:
Maximum (HACR) Circuit Breaker:
Minimum Circuit Ampacity:
Maximum Fuse Size:
Maximum (HACR) Circuit Breaker:
Standard Oversized Motor with Heat
Number:
Horsepower:
Motor speed (RPM):
Phase:
Full Load Amps:
Locked Rotor Amps:
OUTDOOR MOTOR
Minimum Circuit Ampacity:
Maximum Fuse Size:
Maximum (HACR) Circuit Breaker:
ELECTRICAL / GENERAL DATA
Standard Oversized Motor
Standard Motor
Circuit #1 / 2
Circuit #1 / 2
(7)
(6) (4)
(1) (3) (4)
(6) (4)
(6)(6)
(1) (3) (5)
(8) (9)
(8)
(6)(6)
(2)
1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only.
2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
3. Value does not include Power Exhaust Accessory.
4. Value does not include Heater.
5. Value include Standard Motor.
6. Value include Oversized Motor
7. EER is rated at AHRI conditions and in accordance with DOE test procedures.
8. For Compressor Motors and Condenser Fan Motors: Amp draw for each motor; multiply value by number of motors to determine total amps.
9. HP for each compressor.
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 8 of 11
Weight, Clearance & Rigging Diagram - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
CLEARANCE 18"
(457.2mm)
CLEARANCE 38"
(965.2mm)
CLEARANCE 60"
(1524mm)
CLEARANCE 48"
(1249.2mm)
CLEARANCE FROM
TOP OF UNIT 72"
(1828.8mm)
SUPPLY
RETURN
PACKAGED HEAT PUMP - HORIZONTAL
CLEARANCE
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 9 of 11
Weight, Clearance & Rigging Diagram - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
2566.0 lb 2107.0 lb
674.0 lb
485.0 lb
400.0 lb
590.0 lb 57"35"
40.0 lb
F
E
CORNER WEIGHT
B
C
A
D
RIGGING AND CENTER OF GRAVITY
TOOL-LESS HAIL GUARD (FIOPS)
OVERSIZED MOTOR
POWER EXHAUST
HIGH STATIC DRIVE
MANUAL OUTSIDE AIR DAMPER
THROUGHT THE BASE ELECTRICAL (FIOPS)
UNIT MOUNTED CIRCUIT BREAKER (FIOPS)
UNIT MOUNTED DISCONNECT (FIOPS)
POWERED CONVENIENCE OUTLET (FIOPS)
ECONOMIZER / MOTORIZED OUTSIDE AIR DAMPER
ROOF CURB
HINGED DOORS (FIOPS)
ACCESSORY
BASE UNIT WEIGHTS
SHIPPING
CENTER OF GRAVITIYCORNER WEIGHTS
NET (E) LENGHT
NOTE:
1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY.
2. TO ESTIMATE SHIPPING WEIGHT OF OPTION/ACCESSORIES ADD 5 LBS TO NET WEIGHT.
3. NET WEIGHT OF OPTIONAL ACCESSORIES SHOULD BE ADD TO UNIT WEIGHT WHEN
ORDERING FACTORY INSTALLED ACCESSORIES.
4. WEIGHTS FOR OPTIONS NOT LISTED ARE < 5 LBS.
5. WEIGHT ARE OF BASE UNIT ONLY. FOR TOTAL WEIGHT, 10 DIGIT FACTORY INSTALLED
OPTION (ECONOMIZER AND/OR OVERSIZED MOTOR OR FIOP/ACCESSORY WEIGHT
MUST BE ADDED.
(F) WIDTH
INSTALLED ACCESSORIES NET WEIGHT DATA
WEIGHTS
HEATER
DB
A C
SMOKE DETECTORS
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 10 of 11
Accessory - Packaged Heat Pump Units (Dedicated)
Item: A1 Qty: 2
1 9 1 /2 "
6 4 3 /4 "
H O R I Z O N T A L - E C O N O M I Z E R H O O D
A C C E S S O R Y D R A W
I N G
O U T S I D E A I R H O O D
(E C O N O M I Z E R D A M P E R )
E N D P A N E L
O U T S I D E A I R P A N E L /
A C T U A T O R A C C E S S
P A N E LFILTER A C C E S S
D O O R
Tybee Island YMCA Replacement August 22, 2014
FLD = Furnished by Trane U.S. Inc. / Installed by
Others
Equipment Submittal Page 11 of 11
Field Installed Options - Part/Order Number Summary
This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order
numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of
material for the job.
Product Family - Packaged Heat Pump Units (Dedicated)
Item Tag(s) Qty
Description Model Number
A1 No Tag 2 20 Ton Heat Pump Pkg WSH240E3R0A--0
002000000000000
00000000000
Field Installed Option Description Part/Ordering Number
54 kW electric heater 3 ph AYHHTRN354A
0-100% Economizer, dry bulb control BAYECON092B