HomeMy Public PortalAboutConnectionstoLargeSewers-BrickPLACE SHOTCRETE ON
INSIDE OF PIPE AT A
MINIMAL THICKNESS TO
FILL IN BRICK JOINTS.
/.<
j%- MUKIHK MIX
����� EXISTING BRIO
\/\\/�/\//\
NOTES:
CONNECT SEWERS SPRINGLINE
TO SPRINGLINE
CONCRETE COLLAR W/
STEEL REINFORCING
6" MIN.
CORE DRILL EXISTING BRICK
SEWER AFTER CONCRETE COLLAR
AND SHOTCRETE ARE PLACED.
12" MW
►///
/\//
�/\//
/�
6" MIN.
z
N
NEW SEWER
6" MIN.
CLASS "A"
CONCRETE
#5 TOP AND BOTTOM
CONCRETE COLLAR
1) SHOTCRETE SHALL BE PLACED ON THE INSIDE OF THE PIPE PRIOR TO CONCRETE COLLAR. SHOTCRETE
SHALL EXTEND 2 FEET BEYOND THE LIMITS OF THE NEW PIPE.
2) THE REINFORCED CONCRETE COLLAR SHALL BE PLACED PRIOR TO CORE DRILLING. A MINIMUM OF 1 FOOT
BEYOND NEW PIPE.
3) CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO MSD PRIOR TO CONSTRUCTION.
4) CONTRACTOR SHALL REBUILD ANY PORTION OF BRICK SEWER THAT IS DAMAGED DURING CONSTRUCTION.
CONNECTION TO LARGE
SEWERS — BRICK
METROPOLITAN ST. LOUIS SEWER DISTRICT
Standard Details of Sewer Construction
Dr. M.C.K.
Ch. P.W.S.
2009
SHEET 68