Loading...
HomeMy Public PortalAboutDetailsofInletFrameandGrates20" FOR 20" FOR (4)GRATE (4)GRATE USE 2"x 3"x 3/ Z STEEL, " 2'' H f GRATE INLET FRAME PLAN IMEM11% 1" 2-1/2" 15" SECTION F-F DETAILS OF INLET FRAME AND GRATES NOTE: 3/8" DIA. CONTINUOUS ANCHOR IS IN THIS POSITION ONLY FOR CENTER SUPPORT OF DOUBLE 3 GRATE & 2 GRATE INLET WITH SIDE INTAKE UNIT. 6 SECTION A -A 30" 2-1/2" 1" MINIMUM LENGTH WELD ON EACH SIDE. SECTION N-N DETAIL OF CONTINUOUS ANCHOR FOR ANGLE SEAT 6'-0" FOR 8 GRATE (138 LBS.) 4'-8" FOR 6 GRATE (107 LBS.) 8" S 8 x 23 STEEL BEAM FOR CENTER SUPPORT OF 6 OR 8 GRATE INLET TABLE FOR SIZES OF FRAMES 2 GRATE = 30-1/2" x 30-1/2" 3 GRATE = 30-1/2" x 45-1/2" 4 GRATE = 30-1/2" x 60-1/2" NOTE B: PROVIDE 1/8" RAISED LETTERING APPROX. 3/4" TO 1" HIGH. B1: METRO ST. LOUIS. B2: SEWER DIST. SEWERS. MATERIAL: CAST GRAY IRON ASTM, A48. DUCTILE IRON ASTM. A536. CAST IRON GRATE and DUCTILE IRON GRATE METROPOLITAN ST. LOUIS SE R DIS 'ICT Standard Details of Sewer Construction DR. RGW/SAM Ch. J.C.K. 2009 SHEET 47 (REVISED)