HomeMy Public PortalAboutPrecastConcreteUnitfor4WayAreaInlet4-#3 REBARS
NOTES:
4-#3 REBARS
PLAN
58"
3/4" DIA. HOLE
3/4" DIA. HOLE
3-1/2"
48"
8"
8"
3/4" DIA. HOLE
SECTION A —A
8"
3 1/4"
5-1/4"
5"
NOTE 1
10-1 /4"
NOTE 2
1) SET STANDARD INLET STONE IN 3/4" MORTAR BED AND DOWEL WITH 5/8" DIA. 1'-0" LONG PINS
AND GROUT.
2) RAISE TO FINAL GRADE WITH COURSES OF BRICK AND SET THE UNIT TO BASE WITH 3/4" MORTAR BED.
3) THIS UNIT TO BE USED WITH 42 INCH I.D. BASE.
4) 5000 P.S.I. CONCRETE IS REQUIRED.
PRECAST CONCRETE UNIT
FOR
4 WAY AREA INLET
METROPOLITAN ST. LOUIS SEWER DISTRICT
Standard Details of Sewer Construction
Dr. DAB/SAM
Ch. J.C.K.
2009
SHEET 40