Loading...
HomeMy Public PortalAboutPrecastConcreteUnitfor4WayAreaInlet4-#3 REBARS NOTES: 4-#3 REBARS PLAN 58" 3/4" DIA. HOLE 3/4" DIA. HOLE 3-1/2" 48" 8" 8" 3/4" DIA. HOLE SECTION A —A 8" 3 1/4" 5-1/4" 5" NOTE 1 10-1 /4" NOTE 2 1) SET STANDARD INLET STONE IN 3/4" MORTAR BED AND DOWEL WITH 5/8" DIA. 1'-0" LONG PINS AND GROUT. 2) RAISE TO FINAL GRADE WITH COURSES OF BRICK AND SET THE UNIT TO BASE WITH 3/4" MORTAR BED. 3) THIS UNIT TO BE USED WITH 42 INCH I.D. BASE. 4) 5000 P.S.I. CONCRETE IS REQUIRED. PRECAST CONCRETE UNIT FOR 4 WAY AREA INLET METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. DAB/SAM Ch. J.C.K. 2009 SHEET 40