Loading...
HomeMy Public PortalAboutTypical Line Manhole on Pipe Sewer 27%22 Thru 42%22 DiameterC.I. FRAME & COVER. TOP OF MASONRY. 1/2" MIN. 1 TO 3 CEMENT TO SAND MORTAR MIX. (ALL BRICK STRUCTURES) A SURFACE ELEVATION DIA. 26 1/2" MIN. 24" MAX. 5 1/2" 16" 42" or 48" 16" T SEE NOTE 1 4" ROWLOCK 2 N / N 0 k N\\\\\ V. � , p..o. a D.o v' v a . DoQQo �p.o D .4 _° D.p.O D o 'o D o'o - r CLASS "A" CONCRETE INVERT KEYWAYS _ — rflA Ag PLAN B B SECTION A —A „ 3/4" MORTAR BED. Pi U zz 00 0 (c z0 a� 0 N 36" MIN. FOR BRICK z 000 z C71� Qw 0CC 4" ROWLOCK \\\ ARCH cc< 4 .O D '0 • D a- w c) U- A BOTTOM SECTION 4" ROWLOCK ARCH vp p.O v.D.O o.D o p o', p 'o NOTES: 1) INSIDE OF BRICK MANHOLES TO BE PLASTERED WITH 1/2" MIN. 1 TO 3 CEMENT TO SAND MORTAR MIX TO TOP OF LARGEST PIPE. 2) MANHOLE STEPS UNIFORMLY SPACED AT MAX. 16"C—C. CLASS "A" SECTION B—B CONCRETE TYPICAL LINE MANHOLE ON PIPE SEWER 27" THRU 42" IN DIAMETER METROPOUTAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. WSH/SAM Ch. J.C.K. 2009 SHEET 11 (REV)