HomeMy Public PortalAboutUntrappedStreetInletBrickConstruction3/4" EXPANSION
JOINT WHEN SET
IN PAVED AREA.
48"
SEE DETAIL SHEET
44 FOR DOWELS.
a
54"
a
a
0
21"
CLASS "A" CONCRETE.
21"
�l 1
FACE OF INLET STONE
& VERTICAL CURB.
3" DETAIL "A".
1-3/4" DETAIL "B".
EXPANSION JOINT.
8"
38"
EXPANSION
PLAN JOINT.
48"
81„
STONE SET IN 3/4" _
CEMENT MORTAR.
1/2" MIN. 1 TO 3
CEMENT TO SAND
MORTAR MIX.
Po
•4-
D: •p . 1
0 ° D
4 4..'0 .
D.0
�.4
p
PP
EDGE OF SILL.
THERE SHALL BE NO CLIPPED
BRICK SURFACES AND NO
PLASTER ON THE EXPOSED
BRICK MASONRY OF THE
INLET THROAT.
VERTICAL CURB.
FACE OF INLET STONE
AND VERTICAL CURB.
3" DETAIL "A". p p
1-3/4" DETAIL "B".
STANDARD DEPTH)
5-1/2"
i
24"
12"
KEYWAY
DETAIL "A" FOR USE WITH
VERTICAL CURBS AND
CONDITIONS OF STABLE
COMPACTED EARTH BENEATH
PAVEMENT ADJACENT TO
INLET AND GUTTER SUMP.
a
a
0 O C
w
0
U
1/2" MIN. 1 TO 3
CEMENT TO SAND
MORTAR MIX PLASTER.
D 0 ,p
o D
04.0 0.8
. • D o p
°
N)
N
z
0
I-
C
a
a 0 4
of 1-1/2» Pp
D O
D o n 0
35"
51"
PP
0
a
8"
O
o .
VERTICAL SECTION ON
DETAIL "A" AS SHOWN
PP
4 0.
PVMT.
o '.4 .0
31
1"MIN.
3/4" ASPH. JOINT
& SEALER.
3/4" MORTAR BED.
////
4" ROWLOCK DETAIL "B"
ARCH
CONCRETE ENCASEMENT
REQUIRED WHERE COVER
IS LESS THAN 3'-0".
CLASS "A"
CONCRETE.
DETAIL "B" FOR USE IN
NEW CONSTRUCTION WITH
RECENTLY COMPACTED
EARTH BENEATH PAVEMENT
ADJACENT TO INLET AND
GUTTER SUMP.
UNTRAPPED STREET INLET
BRICK CONSTRUCTION
F____
METROPOLITAN ST. LOUIS SEWER DISTRICT
Standard Details of Sewer Construction
Dr. WSH/SAM
Ch. J.C.K.
2009
SHEET 25