Loading...
HomeMy Public PortalAboutMILLER AV_1513.pdfU.S. DEPARTMENT OFKOME;L.A14DSECURITY ELEVATION CERTIFICATE FEDERAL EMERGENCY MANAGEMENT AGENCY I OMB No. 1660_0008 National Flood Invieranee Program Important: Read the instructions on pages 1-9. Expiration Date: July 31, 2015 SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name RON ALTMANN Policy Number A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number. 1513 MILLER AVENUE (CHATHAM COUNTY P.I.N. 4-000a-11-021) City CITY OF TYBEE ISLAND State GA ZIP Code 31328 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 172 WARD NO. 4 TYBEE ISLAND , j4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A5. Lalitude/Longitude: Lat. N 31059'37,6' Long. W 80°51'07.4" Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. AT Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) 244 sq H a) Square footage of attached garage N/A sq tt b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage or enclosure(s) within 1.0 foot above adjacent grade 2 within 1.0 foot above adjacent grade NIA c) Total net area of flood openings in A8.b 400 sq in c) Total net area of flood openings in A9.b NIA sq in d) Engineered flood openings? ® Yes ❑ No d) Engineered flood openings? ❑ Yes ® No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2_ County Name B3. State CITY OF TYBEE ISLAND CHATHAM GEORGIA B4. Map/Panel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) (Zone 13051C0326 F 07-07-14 Effective/Revised Date Zone(s) AO, use base flood depth) 09-26-08 AE 12.0 610. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastai Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) 01. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Ai -A30, AE, AH, A (with BFE), VE, Vi -V30, V (with BFE), AR, AR/A, ARiAE, AR/Al-A30, AR/AH, ARIAO. Complete Items C2.a-h below according to the building diagram specified in Item AT In Puerto Rico only, enter meters. Benchmark Utilized: GA DOT BV 025 4 Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) g) Highest adjacent (finished) grade next to building (HAG) h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable byline or imprisonment under 18 U.S. Code, Section 1001. tAf r, ® Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a c \STE . `y !� Check here if attachments. licensed land surveyor? ® Yes ❑ No Certifier's Name JAMES M. KEATON, RLS License Number GA #2743 Title LAND SURVEYOR Company Name CHATHAM SURVEYING SERVICES, INC Address PO BOX 61649 City SAVANNAH State GA ZIP Code 31420 Signatur Ajj ��, t Date AUGUST 25, 2016 Telephone 912-303-0302 � No. 27 r- 16 - 16SUR`�, - J `IFS FEMA Form 086-0-33 (7112) See reverse side for continuation. Replaces all previous editions. Check the measurement used. 7.2 ® feet ❑ meters 16.6 ® feet ❑ meters 15-3 ® feet ❑ meters NIA. ❑ feet ❑ meters 13.0 ® feet ❑ meters 7.1 ® feet ❑ meters 7.2 ® feet ❑ meters 7..0 ® feet ❑ meters SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable byline or imprisonment under 18 U.S. Code, Section 1001. tAf r, ® Check here if comments are provided on back of form. Were latitude and longitude in Section A provided by a c \STE . `y !� Check here if attachments. licensed land surveyor? ® Yes ❑ No Certifier's Name JAMES M. KEATON, RLS License Number GA #2743 Title LAND SURVEYOR Company Name CHATHAM SURVEYING SERVICES, INC Address PO BOX 61649 City SAVANNAH State GA ZIP Code 31420 Signatur Ajj ��, t Date AUGUST 25, 2016 Telephone 912-303-0302 � No. 27 r- 16 - 16SUR`�, - J `IFS FEMA Form 086-0-33 (7112) See reverse side for continuation. Replaces all previous editions. ELtVAI IUN CIWR I [I-IGA It, page 2 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No_) or P_O. Route and Box No_ Policy Number 1513 MILLER AVENUE (CHATHAM COUNTY P I -N. 4-4008-11-021) City CITY OF TYSEE ISLAND State GA ZIP Code 31328 Company NAIC Number_ SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agenUcompany, and (3) building owner. Comments THIS HOUSE IS ON PIERS WITH A 244 S.F. BLOCK ENTRANCE FOYER BELOW THE FLOOR, ITEM A8a IS THIS ENCLOSURE. ITEMS A8b & A8c ARE ENGINEERED OPENINGS (SMART VENT). THE GROUND FLOOR IS CONCRETE PARKING AND STORAGE WITH VERTICAL LATHING WITH SPACES ON THE EXTERIOR PERIMETER BETWEEN THE COLUMNS, ITEM C2a IS THE GROUND FLOOR. ITEM C2b IS THE HABITABLE FLOOR. C2e IS EXTERNAL HVAC ON A PLATFORM AT THE RIGHT SIDE OF THE HOUSE. ITEM C2h 15 GRADE AT THE REAR PORCH. Sig 17- L-5 Date AUGUST 25, 2616 SEeMN E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items El -E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B. and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor (elevation C2_b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is❑ feet ❑ meters ❑ above or El the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments Check here if attachments SECTION G -- COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 -G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO G3. ❑ The following information (Items G4 -G10) is provided for community floodplain management purposes. G4. Permit Number I G5. Date Permit Issued G6. Date Certificate Of CompliancelOccupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9. BFE or (in Zone AO) depth of flooding at the building site ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑ Check here if attachments FEMA Form 086-D-33 (7112) Replaces all previous editions. ELEVATION CERTIFICATE, page 3 Building Photographs See Instructions for Item A6. IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, andfor Bldg. No.) or P.Q. Route and Box No. Policy Number: 1513 MILLER AVENUE (CHATHAM COUNTY P.I.N. 4-0008-11-021) City CITY OF TYBEE ISLAND State GA ZIP Code 31328 Company NAIC Number_ If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the instructions for Item A6. Identify all photographs with date taken; "Front View' and Rear View; and, if required, "Right Side View' and "Left Side View." When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page. PHOTOGRAPHS TAKEN AUGUST 17, 2015 LL FRONT VIEW j � rr+ •r 7.1 { LEFT SIDE VIEW r FEMA Form 086-0-33 (7112) Replaces all previous editions. ELEVATION CERTIFICATE, page 4 Building Photographs Continuation Page IMPORTANT; In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, andlor Bldg. Noj or P.O. Route and Box No. Policy Number: 1513 MILLER AVENUE (CHATHAM COUNTY P.I.N. 4-0008-11-421) City CITY OF TYSEE ISLAND State GA ZIP Code 31328 Company NAIC Number: If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken; "Front View" and "Rear View'; and, if required, "Right Side View" and "Left Side View.' When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. A 4 .}tom I REAR VIEW eF + RIGHT SIDE VIEW r� FEMA Form 086-0-33 (7112) Replaces all previous editions. - DIVISION. 08 00 00—OPENINGS SECTION: 08 95 43—VENTSIFOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW JERSEY 08071 EVALUATION SUBJECT: SMART VENT' AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540-511; 41540-570; ##1540-574; #1540-524; 41540-514 ice . Ice —� ICC -� PPG �rsrE� Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) award in Excellence" A SubsidiaryEC ria. of CanenirHeiI ser ae_:.nw ICC-F_,S' Erahtatiort Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be c•onstrrred as an endorsement of'the subject of the report or cr recnnrnrerrdaticrrr for its use. There is no i varranty by ICC Evahraiion Service, LLC, express or Implied, as to any.finding at other inatter tri this report, or as to any product covered by the report- A°�S��T � nxe±eraccn ,saw Copyright © 201.5 ICC -ES Evaluation Report ESR -2074 Reissued February 2015 This report is subject to renewal February 2017. www.icc-es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council ' DIVISION: 08 00 00—OPENINGS Section: 08 95 43••—VentslFoundation Flood Vents REPORT HOLDER: SMARTVENT PRODUCTS, INC. 430 ANDBRO DRIVE, UNIT 1 PITMAN, NEW .JERSEY 08071 (877)441-8368 www.sniartyent.com info@smartvent.com EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540.520; #1540521; #1540510; #1540-511; #1540570; #1540-574; #1540524; #1540514 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2012, 2009 and 2006 Intemationaf Building Code° (IBC) ■ 2012, 2009 and 2006 Oternational Residential Code`' (IRC) K 2013 Abu Dhabi Irrtematiol7al Scolding Code (ADIBC)t tThe ADIBC is based on the 2008 IBC 2049 IBC code sec ,ans referenced in this report are the same wrtons in the ADIBC. Properties evaluated: ■ Physical operation ■ Water flow 2.0 USES The Smart Vent' units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters. Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Smart Venfo FVs internal floats are activated, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device_ When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel Smart Vent Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1_ The SmartVENTeStacking Model #1540-511 and FloodVENr Stacking Model #1540-521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The FVs comply with the design principle noted in Section 2.8.2.2 of ASCEISEI 24 for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mmis). In order to comply with the engineered opening requirement of ASCEISEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. 3.3 Ventilation: The SmartVENr Model #1540-510 and SmartVENT5 Overhead Door Model #1540-514 both have screen covers with 114 -inch -by -114 -inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENT`D Stacking Model #1540-511 consists of two Model 91540-510 units in one assembly, and provides 102 square inches (55 806 mm2) of net free area to supply natural ventilation. Other FVs recognized in this report do not offer natural ventilation 4.0 DESIGN AND INSTALLATION SmartVENT�5 and F1oodVENr are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report. The mounting straps allow mounting in masonry and concrete walls up to 12 inches (305 mm) thick. In order to comply with the engineered opening design principle noted in Section 2.6.2.2 of ASCEISEI 24, the Smart Ventre FVs must be installed as f6lows: ■ With a minimum of two openings on different sides of each enclosed area. ■ With a minimum of one FV for every 200 square feet (18.6 m2) of enclosed area, except that the SmartVFNTe Stacking Model #1540-511 and FloodVEN14 Stacking Model 41540-521 must be installed with a minimum of one FV for every 400 square feet (37.2 m) of enclosed area ■ Below the base flood elevation. w With the bottom of the FV located a maximum of 12 inches (305.4 mm) above the higher of the final "Revised July 2015 1(•C -GS Eruhraiien Rcp ws are +xu to he 4 owrucd e,r reprr.nr•nuo;; W012011cs nr nm o!!nr olirmblaes rtur spcii(nf llr nd iressc<!, n r are d+rr to Ire corrstrrr d 7 rye, its urr ccruhirxemeur ofrhe suhrccl o(lhe mmrr or q rce:arrurerrciannn fpr irs we. Here it rro ss-arranty by 1H, hN,11110tinrr Semler, 01"express or iota!+.'d, as !u wly.plrclh}� rrr ofi1C+' ma11er In 1hrs report, or µ5 report- CoWnght C 2015 Page 9 or 2 ESR -2074 I Most Ifdety Accepted and Trusted Page 2 of 3 grade or floor and finished exterior grade immediately are permitted for use in conjunction with breakaway under each opening. walls in other areas. 5.0 CONDITIONS OF USE 6.0 EVIDENCE SUBMITTED The Smart Vent' FVs described in this report comply with, Data in accordance with the ICC -ES Acceptance Criteria or are suitable alternatives to what is specified in, those for Mechanically Operated Flood Vents (AC364), dated codes listed in Section 1.0 of this report, subject to the October 2013 (editorially revised May 2014). following conditions: 7.0 IDENTIFICATION 5.1 The Smart Vent' FVs must be installed in accordance The Smart VEND'' models recognized in this report must with this report, the applicable code and the be identified by a label bearing the manufacturer's name manufacturer's installation instructions. In the event of (Smartvent Products, Inc.), the model number, and the a conaict, the instructions in this report govern. evaluation report number (ESR -2074). 5.2 The Smart Vent* FVs must not be used in the place of "breakaway walls" in coastal high hazard areas.. but TABLE 1—MODEL SIZES MODEL NAME MODEL NUMBER MODEL SIZE (in.) COVERAGE (sq. ft) FloodVEN 1540-520 15 314' X 7314" 200 SmartVENT'g 1540-510 15314' X 731;' 200 FloodVENTO Overhead Door SmartVENT® Overhead Door 1540-524 1540-514 1531"' X 73/4 , 153/4" X 7'/," 200 200 Wood Wall FloodVENT" 1540-570 14" X 831," 200 Wood Wall Flo odVENrOverhead Door 1540-574 14" X 8314" 200 SmartVENTO Stacker 1540-511 161, X 16'' 400 FloodVent® Stacker 1540-521 161, X 161, 400 — . ,I — I — — nun, I bgUCHU IUUL= In ESR -2074 1 Most Widely Accepted and Trusted Page 3 Of 3 FIGURE 1—SMART VENT: MODEL 1540.510 FIGURE 2—SMART VENT MODEL 1540-520 FIGURE 3—SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN