AUTHORIZATION TO ADJUST THE OWNER'S CONTINGENCY
WITHIN THE GUARANTEED MAXIMUM PRICE (GMP)
Project No. VKB 99806900
Project Name: Village of Key Biscayne
Fire / Rescue Building
Administration / Police Building
CONTRACTOR:
James A. Cummings, Inc.
3575 NW 53`d Street
Fort Lauderdale, F133309
DATE OF ISSUANCE: 4/22/02
AUTHORIZATION NO. 02
ARCHITECTS:
OBM Miami
2600 Douglas Rd. Ste. 510
Coral Gables, Fl 33134
Spillis Candela DMJM
800 Douglas Entrance
Coral Gables, Fl 33134
The following is a description of items to adjust the Owner's contingency within the
Guaranteed Maximum Price (GMP). This adjustment does not change the GMP or the
contract time
ROC # Description Deduct
11-F Add floor outlets in the Council Chamber ($2,351.00)
Per Doug Fitzgerald on Sept. 8, 2001.
12-F Add electrical revisions on revised electrical ($12,154.00)
drawings dated 8/7/01 except light fixture revisions.
16-F Add '/2" CDX plywood on ceiling of foyer 248 ($1,474.00)
for code compliance.
19-F Add 6" fiber glass insulation to the perimeter
walls in the attic storage rooms needed to air
condition space.
($785.00)
20-F Add a 10" high raised wood platform in the ($6,530.00)
council chambers requested by VKB.
Provide In accordance with OBM memo
dated 9-5-01.
Add
23-F Add 3 doors, frames and hardware # 004A, 02G ($4,929.00)
and 207B.1 and revise door 239 from a RHR to a
RH swing. In accordance with field directive from
OBM and Frank Barron.
24-F Revise cabinets in accordance with OBM $1,175.00
memo dated 9/27/01
25-F Add thermofiber insulation to walls in offices # ($889.00)
236, 237, 238, and 243 in accordance with OBM
proposal request # 3 dated 3/28/02.
26-F Add two layers of drywall to the ceiling and side ($1,727.00)
wall of elevator #2 shaft in accordance with OBM
field report # 3 dated 3/27/02.
9-P Add 2 fire alarm pull stations in accordance with ($982.00)
Marked up shop drawings.
10-P Add 5 exterior light fixtures as shown on drawing ($1,914.00)
A2.3.11 dated 3/8/01
19-P Revise the carpet in the Administration/ Police Building
From Bentley "Double Entendre" to Bentley "Continuity"
For a credit.
22-P Frame an opening in the drywall partition
Between rooms 1-015 and 1-013 for a window
By the owner.
($502.00)
23-P Change the marble thresholds from white ($127.00)
Carrerra marble to travertine marble.
24-P Change the rain gutters on the Administration/
Police building from 8" to 6" and use stamped
Brackets for a credit.
25-P Provide sleeves and supports for coaxial cable ($2,447.00)
By others from room 1-018 and 1-015 to the flat roof area.
26-P Add bullet proof glass at room 1-018 in
Accordance with Spillis Candela DMJM reply
To RFI PC0071 and their transmittal dated 3/1/02.
($2,770 00)
$6,500.00
$1,817.00
1 !
Total
Fire Station
Administration / Police
Total Adjustment
Current Contingency: $117,373.00
Adjusted Contingency: $87,284.00
Submitte
JA
Date:
Contractor
wed:
Dat .., G
Vil age of Key Biscayne
2-
($30,839.00) $1,175.00
($8,742.00) $8,317.00
($30,089.00)