SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number:
Grady K. & Janis B. Reddick
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number:
Box No.
2 Evelyn Lane
City State ZIP Code
Tybee Island Georgia 31328
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Lot 6 North Wave Subdivision, Phase I
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 32 01'11" Long. 80 51'39" Horizontal Datum: ❑ NAD 1927 ❑x NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 6
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) 1182.00 sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 145
c) Total net area of flood openings in A8.b 1740.00 sq in
d) Engineered flood openings? ❑ Yes ❑x No
A9. For a building with an attached garage:
a) Square footage of attached garage 1182.00 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 145
c) Total net area of flood openings in A9.b 1740.00 sq in
d) Engineered flood openings? ❑ Yes ❑x No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. State
City of Tybee Island 13051
Chatham
Georgia
B4. Map/Panel
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s)
Number
Date
Effective/
Zone(s)
(Zone AO, use Base Flood Depth)
Revised Date
13051C
F
06-17-1986
09-26-2008
VE13
13.0
B10, Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 139:
❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item 69: ❑ NGVD 1929 x❑ NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ❑x No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 086-0-33 (7/15) Replaces all previous editions. I Form Page 1 of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
2 Evelyn Lane
City State ZIP Code
Company NAIC Number
Tybee Island Georgia 31328
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction*x❑ Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations—Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, AR/AE, AR/Al—A30, AR/AH, AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto
Rico only, enter meters.
Benchmark Utilized: Vertical Datum:
Indicate elevation datum used for the elevations in items a) through h) below.
x❑ NGVD 1929 ❑ NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor)
7.7x❑ feet ❑ meters
b) Top of the next higher floor
17.0x❑ feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only)
14.9x❑ feet ❑ meters
d) Attached garage (top of slab)
7.7 ❑x feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building
14.6 x❑ feet ❑ meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG)
7.2 feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG)
8.1 feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including
7 z x meters
❑ feet ❑
structural support
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
/ certify that the information on this Certificate represents my best efforts to interpret the data available. 1 understand that any false
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No
❑ Check here if attachments.
Certifier's Name License Number
Warren E. Poythress 1953
Title
Georgia Registered Land Surveyor
fit` . r, �ws,•
-
No. 53, -
Company Name
Poythress Land Surveying, Inc.
tee,
Address716duR..
991 Hunters Road
l,�pEPr•�1,,\`````
City State ZIP Code
Sylvania Georgia 30467
Signature Date Telephone
06-27-2018 (912) 857-3288
Ext.
Copy all pages of this Elevation C iflcate and all attachments for (1) community official, (2) insurance
agent/company, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
1) Type of equipment - Heat Pump A/C
2) The first floor is surrounded by board walls with 1" Gap to act as flood openings as shown on photos.