Loading...
HomeMy Public PortalAboutWest Construction Contract Phases 1 and 2 - GMP2.pdfDocument Al 33" — 2009 Exhibit A Guaranteed Maximum Price Amendment for the following PROJECT: (Name and address or location) Tybee Island Marine Science Center, North Beach Facility Lot 2367 Fort Screven Ward Tybee Island, GA 31328 THE OWNER: (Name, legal status and address) The City of Tybee Island, Georgia a Georgia municipal corporation 403 Butler Avenue, P.O. Box 2749, Tybee Island, Georgia 31328 THE CONSTRUCTION MANAGER: (Name, legal status and address) West Construction Company GA, LLC a Georgia Limited Liability Company 41 Park of Commerce Way, Ste 308 Savannah, GA 31405 ARTICLE A.1 § A.1.1 Guaranteed Maximum Price for Phases 1 & 2 ("GMP 2") Pursuant to Section 2.2.6 of the Agreement, the Owner and Construction Manager hereby amend the Agreement to establish a Guaranteed Maximum Price for Phases 1 & 2 ("GMP 2"). As agreed by the Owner and Construction Manager, the GMP 2 is an amount that the Contract Sum for Phases 1 and 2 shall not exceed. The Contract Sum consists of the Construction Manager's Fee plus the Cost of the Work for Phases 1 and 2, as that term is defined in Article 6 of this Agreement. This Amendment supersedes the Guaranteed Maximum Price Amendment for Phase 1 of the Project ("GMP V). § A.1.1.1 The Contract Sum for Phases 1 and 2 is guaranteed by the Construction Manager not to exceed Three Million, Five Hundred Eight Thousand, Eight Hundred Seventy -Two Dollars ($ $3,508,872.00 ), subject to additions and deductions by Change Order as provided in the Contract Documents. § A.1.1.2 Itemized Statement of the Guaranteed Maximum Price. Provided below is an itemized statement of the Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2") organized by trade categories, allowances, contingencies, alternates, the Construction Manager's Fee, and other items that comprise GMP 2. (Provide below or reference an attachment.) An Itemized Statement of GMP 2 entitled "Tybee Island Marine Science Center" and dated April 12, 2019, which is attached as GMP 2 - Exhibit 1 § A.1.1.3 The Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2") is based on the following alternates, if any, which are described in the Contract Documents and are hereby accepted by the Owner: (State the numbers or other identification of accepted alternates. If the Contract Documents permit the Owner to accept other alternates subsequent to the execution of this ADDITIONS AND DELETIONS: The author of this document has added information needed for its completion. The author may also have revised the text of the original AIA standard form. An Additions and Deletions Report that notes added information as well as revisions to the standard form text is available from the author and should be reviewed. A vertical line in the left margin of this document indicates where the author has added necessary information and where the author has added to or deleted from the original AIA text. This document has important legal consequences. Consultation with an attorney is encouraged with respect to its completion or modification. AIA Document A201 Tm-2007, General Conditions of the Contract for Construction, is adopted in this document by reference. Do not use with other general conditions unless this document is modified. Init. AIA Document A133T —2009 Exhibit A. Copyright O 1991, 2003 and 2009 by The American Institute of Architects. All rights reserved. WARNING: This AIA' Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or distribution of this AIA® Document, or any portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was I produced by AIA software at 08:59:13 ET on 04/17/2019 under Order No.9586693323 which expires on 04/16/2020, and is not for resale. User Notes: (1631024468) Amendment, attach a schedule of such other alternates showing the amount for each and the date when the amount expires.) A Value Engineering statement entitled "TIMSC" and dated April 11, 2019, which is attached as GMP 2- Exhibit 2 § A.1.1.4 Allowances included in the Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2"), if any: (Idents allowance and state exclusions, if any, from the allowance price.) Item Dumpster Enclosure Price ($0.00) $12,000 § A.1.1.5 Assumptions, if any, on which the Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2") is based: GMP 2 is based on the assumptions set forth in the attached document entitled "Tybee Island Marine Science Center Clarifications" dated April 15, 2019, which is attached as GMP 2- Exhibit "3" § A.1.1.6 The Guaranteed Maximum Price is based upon the following Supplementary and other Conditions of the Contract: Document Title Date Pages A201-2007 General Conditions of Approved by City of the Contract for Tybee on 7/12/18 Construction § A.1.1.7 The Guaranteed Maximum Price is based upon the following Specifications: (Either list the Specifications here, or refer to an exhibit attached to this Agreement) "Tybee Island Marine Science Center Clarifications" dated April 15, 2019, and attached as GMP 2- Exhibit "3" Section Title Date Pages § A.1.1.8 The Guaranteed Maximum Price is based upon the following Drawings: (Either list the Drawings here, or refer to an exhibit attached to this Agreement.) Plan of Tybee Island Marine Science Center, KC Project #120418 dated November 13, 2018 which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "4". Construction Drawings for Proposed Drawings for Tybee Marine Science Center by Kern & Co. LLC dated March 19, 2019, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2 - Exhibit "5" Floor Plan Markups Sheet Al. I for Proposed Drawings for Tybee Marine Science Center by Kern & Co. LLC dated 3/28/19, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2 - Exhibit "6" Proposed Drawings for Tybee Marine Science Center Sheet No. A6.2 by Kern & Co. LLC dated 12/20/18, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "7" Proposed Drawings for Tybee Marine Science Center Sheet No. A6.3 by Kern & Co. LLC dated 4/1/19, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "8" Proposed Drawings for Tybee Marine Science Center Sheet No. S1.0 by Kern & Co. LLC dated 3/21/19, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "9" Proposed Drawings for Tybee Marine Science Center Sheet No. S1.1 by Kern & Co. LLC dated 3/21/19, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "10" Proposed Drawings for Tybee Marine Science Center by Kern & Co. LLC with Sottile Notes dated 3/29/19, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "11" Number Title Date § A.1.1.9 The Guaranteed Maximum Price is based upon the following other documents and information: (List any other documents or information here, or refer to an exhibit attached to this Agreement.) AIA Document A733" —2009 Exhibit A. Copyright O 1991, 2003 and 2009 by The American Institute of Architects. All rights reserved. WARNING: This AIAm Init. Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or distribution of this AIA® Document, or any 2 portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was t produced by AIA software at 08:59:13 ET on 04/17/2019 under Order No.9586693323 which expires on 04/16/2020, and is not for resale. User Notes: (1631024468) June 13, 2018 Report of Geotechnical Evaluation Services by Whitaker Laboratory, Inc. attached hereto as GMP 1 - Exhibit "12" ARTICLE A.2 § A.2.1 The anticipated date of Substantial Completion for Phase I established by this Amendment: Wed June 5, 2019 The anticipated date of Substantial Completion for Phase 2 established by this Amendment: Thursday, February 20, 2020 - O (Signature) (Printed name and title) CON TRU MAN R (Signature) 47 (Printed name and title) AIA Document A133* — 2009 Exhibit A. Copyright C 1991, 2003 and 2009 by The American Institute of Architects. All rights reserved. WARNING: This AIA® Init. Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or distribution of this AIA® Document, or any 3 portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was produced by AIA software at 08:59:13 ET on 04/17/2019 under Order No.9586693323 which expires on 04/16/2020, and is not for resale. User Notes: (1631024468) Additions and Deletions Report for AIA® Document A 133" — 2009 Exhibit A This Additions and Deletions Report, as defined on page 1 of the associated document, reproduces below all text the author has added to the standard form AIA document in order to complete it, as well as any text the author may have added to or deleted from the original AIA text. Added text is shown underlined. Deleted text is indicated with a horizontal line through the original AIA text. Note: This Additions and Deletions Report is provided for information purposes only and is not incorporated into or constitute any part of the associated AIA document. This Additions and Deletions Report and its associated document were generated simultaneously by AIA software at 08:59:13 ET on 04/17/2019. PAGE Tybee Island Marine Science Center, North Beach Facility Lot 2367 Fort Screven Ward Tybee Island, GA 31328 The City of Tybee Island, Georgia a Georgia municipal corporation 403 Butler Avenue, P.O. Box 2749, Tybee Island, Georgia 31328 West Construction Company GA, LLC a Georgia Limited Liability Company 41 Park of Commerce Way, Ste 308 Savannah, GA 31405 § A.1.1 Guaranteed Maximum Price for Phases 1 & 2 ("GMP 2") Pursuant to Section 2.2.6 of the Agreement, the Owner and Construction Manager hereby amend the Agreement to establish a Guaranteed Maximum Mise -Price for Phases 1 & 2 ("GMP 2"). As agreed by the Owner and Construction Manager, the GMP 2 is an amount that the Contract Sum for Phases 1 and 2 shall not exceed. The Contract Sum consists of the Construction Manager's Fee plus the Cost of the WeFk, Work for Phases 1 and 2, as that term is defined in Article 6 of this Agreement. This Amendment supersedes the Guaranteed Maximum Price Amendment for Phase 1 of the Project ("GMP 1 "). § A.1.1.1 The Contract Sum for Phases 1 and 2 is guaranteed by the Construction Manager not to exceed Three Million, Five Hundred Eight Thousand, Eight Hundred Seventy -Two Dollars ($ $3,508,872.00 ), subject to additions and deductions by Change Order as provided in the Contract Documents. § A.1.1.2 Itemized Statement of the Guaranteed Maximum Price. Provided below is an itemized statement of the Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2") organized by trade categories, allowances, contingencies, alternates, the Construction Manager's Fee, and other items that comprise *he Qua-^n*eea M aiiiinuf-. Pr -ie &. -GMP 2 An Itemized Statement of GMP 2 entitled "Tybee Island Marine Science Center" and dated April 12, 2019, which is attached as GMP 2 - Exhibit 1 § A,1.1.3 The Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2") is based on the following alternates, if any, which are described in the Contract Documents and are hereby accepted by the Owner: PAGE 2 Additions and Deletions Report for AIA Document A1133--2009 Exhibit A. Copyright ® 1991, 2003 and 2009 by The American Institute of Architects. All rights reserved. WARNING: This AIA's Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or distribution of this AIA® Document, or any portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was produced by AIA software at 08:59:13 ET on 04/17/2019 under Order No.9586693323 which expires on 04/16/2020, and is not for resale. User Notes: (1631024468) A Value Env gineeringstatement entitled "'l IMSC" and dated A ril 11 2019 which is attached as GMP 2- Exhibit 2 § A.1.1.4 Allowances included in the Guaranteed Maximum P +iee Price for Phases 1 and 2 ("GMP 2"l, if any: Dumpster Enclosure $12,000 § A,1.1.5 Assumptions, if any, on which the Guaranteed Maximum Price for Phases 1 and 2 ("GMP 2") is based: GMP 2 is based on the assumptions set forth in the a_ttached document entitled "Ty bee Island Marine Science Center Clarifications" dated April 15, 2019, which is attached as GMP 2- Exhibit "3" A201-2007 General Conditions of Approved by City of the Contract for Tybee on 7/12/18 Construction "Tvbee Island Marine Science Center Clarifications" dated April 15, 2019, and attached as GMP 2- Exhibit "3" Plan of T bee Island Marine Science Center KC Proiect 9120418 dated November 13 20 18 which are hereby incorporated by this reference. The cover page far these drawings is attached as GMP 2- Exhibit "4". Construction Drawin s for Proposed Drawings for Tybee Marine Science Center by Kern & Co. LLC dated March 19 2019 which are hereby ince orated by this reference. The cover page for these drawings is attached as GMP 2 - Exhibit "5" Floor Plan Markus Sheet Al.I for Proposed Drawings for Tybee Marine Science Center by Kern & Co. LLC dated 3/28119 which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2 - Exhibit "6" Proposed Drawings for Ty bee Marine Science Center Sheet No. AU by Kern & Co. GLC dated 12/20/18 which are hereby incorporated by this reference. "Che cover page for these drawings is attached as GMP 2- Exhibit "7" Proposed Drawing=s for Tybee Marine Science Center Sheet No. A6.3 by Kern & Co. LLC dated 411/19, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- E liibit "8" Proposed Drawings for Tybee Marine Science Center Sheet No. S1.0 by Kern & Co. LLC dated 3/21119, which are hereby incorporated by this reference. The cover page for these drawings is attached as GMP 2- Exhibit "9" Proposed Drawings for Tybee Marine Science Center Sheet No. S I.1 by Kern & Co. LLC dated 3/21119 which are hereby incorporated by this reference, The cover page for these drawings_ is attached as GMP 2- Exhibit "10" Proposed Drawings for Tybee Marine Science Center by Kern & Co, LLC with Sottile Notes dated 3/29/19, which are h creby i ncoERorated by this reference. The cover Rage for these drawin gs is attached as GMP 2- Exhibit "I I" PAGE 3 June 13 2018 Report of Geotechnical Evaluation Services by Whitaker Laboratory, Inc. attached hereto as GMP (- Exhibit "12" § A.2,1 The anticipated date of Substantial Completion for Phase 1 established by this Amendment: Wed June 5, 2019 The anticipated date of Substantial Completion for Phase 2 established by this Amendment: Thursday, February 20, 2020 Additions and Deletions Report for AIA Document A133' —2009 Exhibit A. Copyright O 1991, 2003 and 2009 by The American Institute of Architects. All rights reserved. WARNING: This AIAs Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or distribution of this AIA® Document, or any portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was produced by AIA software at 08:59:13 ET on 04/17/2019 under Order No.9586693323 which expires on 04/16/2020, and is not for resale. User Notes: (1631024468) Certification of Document's Authenticity AIA® Document D401 TM —2003 I, E-RHoiiNiday, hereby certify, to the best of my knowledge, information and belief, that I created the attached final document simultaneously with its associated Additions and Deletions Report and this certification at 08:59:13 ET on 04/17/2019 under Order No. 9586693323 from AIA Contract Documents software and that in preparing the attached final document I made no changes to the original text of AIA® Document A133TM — 2009 Exhibit A, Guaranteed Maximum Price Amendment, as published by the AIA in its software, other than those additions and deletions shown in the associated Additions and Deletions Report. ,G: (Signed) (Title) 711 (Dated) AIA Document D401 T" — 2003. Copyright O 1992 and 2003 by The American Institute of Architects. All rights reserved. WARNING: This AIA" Document is protected by U.S. Copyright Law and International Treaties. Unauthorized reproduction or distribution of this AIA° Document, or any portion of it, may result in severe civil and criminal penalties, and will be prosecuted to the maximum extent possible under the law. This document was produced by AIA software at 08:59:13 ET on 04/17/2019 under Order No.9586693323 which expires on 04/16/2020, and is not for resale. User Notes: (1631024468) GMP 2- Exhibit 1 WE WEST CONSTRUCTION COMPANY General Conditions 265,522.00 Temporary Toilets 3,360.00 Temporary Utilities 10,000.00 Temporary Office Trailer 9,980.00 Project Manager 54,180.00 Superintendent 120,400.00 Project Administration 7,000.00 Interim Clean-up 8,428.00 Dum ster 15,925.00 Rental Equipment 12,040.00 Final Cl aning 2,459.00 Temporary Protection 9,030.00 Temporary Site Fencing 7,720.00 Legal Fees 3,500.00 Plan Reproduction 1,500.00 Testing & Special Inspections By Others Sitework 182,091.00 Site Pre eration 24,260.00 Field Engineering 3,500.00 Earthwork 36,625.00 Soil Treatments 738.00 Utilities within 5' of building) 55,163.00 Paying 43,005.00 Landscaping & Irrigation 6,800.00 Site Improvements dum ster enclosure 12,000.00 Concrete 664,066.00 Foundation, Piers & PT Slab 560,403.00 Pavers & Header Curb 60,480.00 Cistern 40,683.00 Equipment Pads 2,500.00 Metals 201,270.00 Structural Steel 70,200.00 Metal Railings 58,410.00 Metal Railings 72,660.00 Woods, Plastics & Composites 692,285.00 Rough Carpentry 268,720.00 Exterior Finish Carpentry 280,986.00 Interior Finish Carpentry 142,579.00 Architectural Woodwork - Thermal & Moisture Protection 297,667.00 Insulation 15,764.00 Membrane Roofing 55,683.00 Pedastal Paver System 186,905.00 Joint Sealants 9,441.00 Flashings & Window Pans 23,321.00 Column Cas 6,553.00 O enin s 420,317.00 Doors, Frames & Hardware 62,732.00 Aluminum Storefront 249,113.00 Bi -Folding Doors 58,372.00 Aluminum Gate Frames 50,100.00 Finishes 82,249.00 Drywall 5,380.00 Tiling 3,968.00 Painting 72,901.00 Specialties 4,339.00 Fire Extinguishers 2,908.00 Toilet Accessories 1,431.00 Equipment - A fiances By Others Conveying Equipment 81,550.00 LULA Lift 81,550.00 Mechanical 147,138.00 Plumbing 40,318.00 HVAC 106,820.00 Electrical 123,830.00 Electrical 113,930.00 Fixtures In Above Data Wiring, Security System, A/V, Fire Alarm By Others Generator 9,900.00 Sub -Total: Permitting Allowance: Builder's Risk P & P Bond Fee: 3,162,324.00 By Owner 26,973.00 54,036.00 163,848.00 BUILDING TOTAL: $ 3,407,181.00 PROJECT TOTAL $ 4,008,872.00 GMP 2- Exhibit 2 WE PO Box 61388 Savannah, GA 31420 / 912-721-4820 Page 1 Alternate Pricing Options Price Adjustment Accepted Budget Base Bid $ 3,703,973.00 1 Delete air barrier (Zip Wall will meet requirements with Boral Nickel Ga (47,854.00) Y (47.854.00) 2 Electrical changes: a Alternate electrical plan & revised fixtures 30,278.00 Y OR b Per Craig's mark-ups 17,835.00 17,835.00) c Reduce generator load 29,742.00 Y 29,742.00 3 Delete fire alarm 7,892.00 Y ,892.00 4 Alternate education room wall design ,995.00 Y ,995.00 5 Black Locust wood deck tiles in lieu of Bamboo 61,265.00 Y 61,265.00 G Alternate decking: a I e decking in lieu of Bamboo 1,786.00 OR b) Garappa in lieu of Bamboo 20,649.00) Y (20,649.00) Alternate ext trim scheme oral 80,759.00 Y (80,759.00) 8 Metal panels in lieu of aluminum frames & wood slats 9 Add for deck brackets a wood 57,482.00 OR b steel 62.491.00 Y 62,491.00 10 Alternate water pipe routing at ground floor(per Crai 's sketch 4,654.00 Y 4,654.00 11 Add fluid a lied waterproofing at PT deck 21,263.00 12 Reduced structural steel scope per permit drawings 20,328.00) Y (20,328.00 13 Revised Framing package 27,156.00 Y 27,156.00 14 Reduce H&I sotrefront elevations in height to eliminate curtain wall 19,301 00) Y 19,301.00 15 Add for accurate elevator quote 17,954.00 Y 17,954.00 16 Add file scope to bid (originally omitted from estimate 4.245.00 Y 4,245.00 1 Will 's piling cap in lieu of allowance (5,828.00) Y 5,828.00 18 TPO in lieu of standing seam at East Gallery roof (8,412.00) Y 8,412.00 19) Alternate metal frames with mesh panels Includes adding metal panels at undercroft in lieu of the hog pen fence. (17,677.00) Y (17,677.00) Total Recommended Reductions (292,657.00) Revised Budget with Recommended Reductions $ 3,411,316.00 Recreational Allowance 500.000.00 Contin en , 102.339.00 PROJECT TOTAL $ 4,013,655.00 November Budget 4,008,872.00 Delta 4.783.00 PO Box 61388 Savannah, GA 31420 / 912-721-4820 Page 1 GMP 2- Exhibit 3 Tybee Island Marine Science Center Clarifications April 15, 2019 1. i'ricing is based on the civil plans by Bern & Co dated 11/13/18 and the March Permit Drawings dated 3/19/19. Additionally, the fallowing VE sketch or revisions were included: a. 51.0 & Sl.l dated 3/21/19 b. S14 & S3.2 progress prints dated 4/3/19 c. Al Moor Plan Mark-ups by Kern & Co dated 3/28/19 d. A6.2 & A6.3 revisions dated 4/1/19 e. Sottile Notes — TIMSC — 3/29/19 2. The cost of the building permit is not included and is to be handled internally by the City. 3. We have not included the cost of the water meter or any associated utility tap or impact fees. 4. Third party special inspections are not included in our proposal. It is assumed these are by - owner. 5. Our schedule allots for a construction period of 14 months for the complete project. 1. Includes all erosion controls, civil demo and fill to install the building pad. 2. Removal and replacement of any unsuitable soils is not included in this estimate and will be handled on a unit cost basis as discovered. The unit cost for muck & fill of unsuitable soils is $35/CY. 3. Removal and replacement of any underground structures are not included in this estimate and will be handled on a time and material basis if discovered. 4. We have not included any allowance for dewatering in our estimate. Any dewatering required 5. will be bill on a time and material basis. 6. No site lighting fixtures or conduits are included in this estimate. 7. Any demolition of utility services is. to be by others. 8. No testing or abatement of hazardous materials is included. 9. An allowance of $12,000 is included for the dumpster enclosure. 10. We have included the landscaping included in the civil drawings in our pricing as the base, code required landscape package. Additional landscapes and hardscapes pending design are not included in our budget. 1. The concrete estimate includes the earth formed footings, concrete piers, the concrete cistern and post -tensioned slab. 2. The ramp structure is included per the revisions by Kern & Co. to S1.0 & S1.1 dated 3/21/19. 3. The walls of the ramp & the cistern will have a "board form" finish. 1. The structural steel & metal fabrications package includes the following: a. Fabrication, delivery, erection & shop drawings b. all embedded items shown on plans c. 16 HSS columns with saddles d. '/a" A36 galvanized vertical rod braces with clevis', turnbuckles and connection plates e. 3 x 3 x 3/4 galvanized rolled angle to support 1 14" grating at the cistern f. Structural steel in conditioned space will receive 2.0 mils of standard shop primer gg Expposed steel will be hot dip galvanized h. Galvanized brackets for all deck to concrete column connections per MacAljon's preliminary design. Final design to be provided by Dern & Co. 2. The metal tailings are based on powder coated aluminum railings. Our supplier feels that these will hold up in the environment that the building is in but will require twice monthly rinsing with fresh water. Wood, Plastics & Composites 1. The rough carpentry includes the labor and materials to frame the building and decks. The truss package is included in this line item. The wood truss package budget is based on the information available at the time of this pricing exercise. Any changes while finalizing the truss design will be subject to additional cost. The following information was included in the final truss pricing: a. Email dated 4/3/19 from Rachel Lancaster with comments on preliminary truss package drawings entitled `vTIMSC Prelim Truss Review." b. S1.4 &S3.2 — Progress Print 4/3/19 2. The exterior trimpackage is based on the following: a. Al Floor Plan Mark-ups by Dern & Co dated 3/28/19 b. Boral channel siding c. Boral trim at the eaves & soffit with Boral beadboard d. Corners, pilasters, casings, watertable (with PT drip cap), porch column wrap (6x6 PT columns). e. Sills to be KDAT f. Any hog pen fencing locations are KDAT frames with BJDATslats g. Decking based on 5/4" x 6" Garappa, eased edge with exposed stainless-steel fasteners 3. The interior finish carpentry includes the following: a. Trim boards to be 1x "C" SYP material b. Ceilings and walls to be 1x6 shi lap wall paneling with #2 pine c. Stair stringers and treads to be 41 Common SU d. Mesh riser will be in a frame and not "kerfed" into the stair tread 4. All cabinetry and countertops are by others. The insulation scheme is based on R-19 open call foam in the walls & R-30 open cell foam in the roof deck. An ignition barrier was not included. The Gip -Wall system was included in the framing package for the wall sheathing so no .air barrier is required. The roofin system will be a 60 mil, fully adhered TPQ membrane roof with 1" of ISO insolation. The gravel stop will be pre -painted, 24 Ga Kynar painted steel in standard colors. This roofing system comes with a 20 -year manufacturer's warranty and a 2 -year workmanship warranty. a. The standing seam roof shown in the plans has been changed to a TPO membrane roof. 4. The waterproofing membrane at the covered deck area will be a 3 -ply Ruberoid Torch smooth membrane over tapered ISO insulation at 1/4",per foot slope. 5. Over the concrete deck we have included a 1" layer of insulation board. No waterproofing is included at the interior concrete deck. 6. A pedestal paver system with 2' x 2' RobiDecking Black Locust wood deck tiles is included at all interior floor locations as noted. 7. Joint sealants are included at the slab saw joints and in the concrete pavement and sidewalk joints. 8. Copper flashings are included at all openings and at the watertable per drawings. Copper window pans are included at all openings. 9. We have included the Copper Half Crone Piling Cap by Willy's Metal Piling Caps at 24 locations. 1. The hollow metal door and frame are galvanized, heavy duty series and wind loaded. 2. The interior stile & rail wood doors are by Harring. They are paint grade 1 panel configuration with wood frames and pre -machined. 3. The hardware package is in accordance with the hardware specifications provided. Chanes have been made toinclude wind load certified products were not specified. The exit devices on single exterior doors were changed from a surface vertical rod to a rim device. The closers were changed from Sargent 351 to Sargent 1431. Hardware at the Hog Pen doors to includes continuous bin es, surface. bolts., pulls and door closers. 4. Exterior windows and bin oors are as follows: a. Aluminum storefront system to be YKK THS 50 Tu 2-1/2" x 5" which is an impact rated, thermally improved storefront system for insulated glass. Finish to be dark bronze anodized. Glazing to be 1-5/16" impact rated, clear laminated units with Solarban60#2. b. Entrances to be YKK 35H which are medium stile, impact rated doors. Doors to be provided with YKK impact rated hardware to included surface mounted closers, butt hinges and ms locks. l�inish to be dairk bronze anodized. Glazing to be 9/16" impact rated, clear laminated units with Solarban60#2. c. Interior storefront system to be YKK YES 45 FS 1-3/4" x 4-1/2" which is a non- rated, center set storefront system for monolithic glass. Finish to be dark bronze anodized. d. Shop drawings with PE stamp included. a. The curtainwall storefront system has been eliminated from the scope with the H&J openings being reduced in size per A6.2 & A6.3 revisions dated 4/1/19. S. The three bi-fold units are to be stain grade Sapele, fully glazed wood doors hung from a ceiling mounted track. The Education Room doors were changed per A6.2 & A6.3 revisions dated 4/1/19. 1. Drywall walls and ceilings are included in the bathrooms and elevator shaft. 2. A tile floor is included at the bathrooms. A material allowance of $5/SF is included. 3. Painting includes finishing of all interior & exterior wall and ceiling surfaces. Concrete deck, columns, ramp walls, etc are to remain unfinished. Garappa deck to receive a penetrating sealer. 1. Five fire extinguishers and semi -recessed cabinets are included. 2. Toilet accessories as specified are included in the bathroom. Conveying Equipment i 1. The L UL.A lift is based on the Savaria )= lift. It has a 1,400 lb capacity and travels at 30 fpm. There are two stops over an approximately 11 -foot travel span with two openings. The car enclosure is white steel and the fixtures are stainless steel. The entrances have a standard grey finish. 1. The plumbing system budget is bayed on the plans and specifications provided by Kern & Co. The water piping to the exterior hose bibbs has been reduced per the Sottile Notes — TIMSC — 3/29/19. 2. A fire sprinkler system is not included in the budget. 3. The HVAC system is per the plans and specifications. 1. 'Me electrical system is based on the plans and specifications as well as the Sottile Notes — TIMSC — 3/29/19. The lighting and power below the building is based on these mark-ups. 2. Theenerator is based on a Generac — G007029-1 per the email From Nick Forteriberry date 4/9/19 entitled "Re: J�ybee MSC Lighting Re-selecuons." The propane tank will be provided and filled by others. We have included a woos] framed platform for the generator but no foundation for the propane tank. 3. A low voltage wiring & systems for A/V, security, fire alarm and data is to be by others. GMP Z- Exhibit 4 Q Z a 00 N W W O <z K 0 0 0 z USE=e - J( ------------ V � a z ryo USE=e - J( V z GMP 2- Exhibit 5 U21I I213 93NROS HNIUVW 21219A.L ia�srino� O 'D11 ` OD 2g uaa}I xoa SONIAvxa aasoaoxa z 3 - 6aa p. 6Spp p ease p pp pa� i6i iaa Sap s s ss sEM - E rgx E _ ___ _ _____ lin 16; q� 5 e irl i� ���� r. '"' 2 WSS tl �� 5� •'�' � S: !-C � �444�� � �Q 29�4d � i'iyIT �FaE: ':a@sa"s'- iai ire: C9 e W g f On � n aLu y5yp❑®aoo 6 �'�9 rr� n❑®O❑ Lim 1(4 Z Lu H .. V- W Z W H F A } ♦/� � � � i;e3 � i�iy 9 v O w is a 1 19 € !€- xll I MU - a a@fix GMP 2- Exhibit 6 t ' ]' -UT I)jai oa a a s�lsr�vxaIso oax ��� C X s z $< S7 +ry IL i5a _ a Y' t T�r7 §=YO Ug fir` ... A F r .. O T ^ f v GMP 2- Exhibit 7 HRJNgZ) 9DNaI3S aNIUVW 99 RAI OD 2- ul;�iNwl HOd S9NIMV2IG GHSOdOldd o. Ffl 4 A -1 11 p 19, 19 0 El. I 1 O I �4 7, i LU Lou uj F= U) Q U) l mmmmmmmw_-Z� JIM III iq 14 oa I I WOM a 6 JIM JIM I 11 �- , WE lim O GMP 2- Exhibit 8 I el ....�.a �n • «Z�ri • �••••���-.�• • ?I�ZN�� ��AI�I�S �AII2IVLII ��9.I,L JII`' o uja}I t 2103 S9NIMVH(I QASOdONd o az - l I el GMP 2- Exhibit 9 I-- GMP 2- Exhibit 10 ..—.—.....�',�'.� �`. � �•••"W,v� ' � z '?': .,mnnnu-�avn�ma. uea 2 ;. C F s�Y�q iw.�r�� nyn,Y ri,rj. s,wwl .: 7 D � Uz 1 27 ��I 2loa S`JAII VH(l a3Soao2l a sb'g X / 45 C s w^ is z sb'g X / 45 C s GMP 2-- Exhibit 11 '"m w uj 0 z LL W Cl) u CD w Z L) z LLJ C/) LLI Z w Cl) 0 a. 0 Lu W Lu CL - - - - --- - - - - - - . . . . . . . . a`:8 O m , ;q z N I IN I NO lilt I'M Rh M, fill Hod SONUMU U21sodoud .......... . .......... ...... _Seas.... ......... ........ ..................... H WSH�, .. .. ......... HM�aj� ---Tq sj;aj_�J% '"m w uj 0 z LL W Cl) u CD w Z L) z LLJ C/) LLI Z w Cl) 0 a. 0 Lu W Lu CL - - - - --- - - - - - - . . . . . . . . a`:8 O m , ;q z N I IN I NO lilt I'M Rh M, fill " -" ` " " a -�� """ ��I�� z) HONHIJS aMI2I W HHgA . om+ _ 1 .y lq.ii l mlw ��i��en- - P-I DII��' o�� 2g uaax 3 .ti 1103 S9NIdAVU(I aRSOdOad i n iW M L-n a a f - I. �� I " i p i " - ;9 L ji i HOA SONI&VUU GHSOdOldd wi NA -1 40M 1 Ali I All 0 j PSA 2g uaax li7.I sm aammOS aHImm aaa&L VOdSO IIdAVJaQaSOdoud sNou vn7ri ovri�+or! e- �e �F Y 4 �I av a NA••g� i �� + �+T� ' H�a:)1213NaIDS aNnIVW 3a9A.L t a vis v F• _ DTIO� M?g iT�2x : u Hoa SJNLAVHQ aasoaoua ; �a � e = 5= LL 3 [ 7i 1 ' I 1y l I is 4 i y,_ 1iii Y I �aa 06 I' l'7y� F s lilt } OF i a GMP 2- Exhibit 12 Geotechnical Engineering Report Proposed Tybee Island Marine Science Building Tybee Island, GA June 13, 2018 Project No. 7-6-15-1-R2 Prepared For: Tybee Marine Science Tybee Island, GA Prepared By: Whitaker Laboratory, Inc. Savannah, GA m June 13, 2018 WHITAKER 1ABORATORY, INC. P.O. Box 7078 2500 Tremont Road Savannah, Georgia 31418 (912) 234-0696 Fax (912) 233-5061 Email: info@whitakeriab.net Tybee Marine Science Ms. Maria Procopio mariat raco io mail.com maria tybeemarinescience.orq Referencing: Report of Geotechnical Evaluation Services for Proposed Tybee Island Marine Science Building North Beach, Tybee Island, GA Report No.: 7-6-15-1-R2 Dear Ms. Procopio, As requested, WHITAKER LABORATORY, INC. has conducted a geotechnical investigation at the above referenced site. Authorization to perform this investigation was provided by your acceptance of our proposal dated June 22, 2015. Our findings and recommendations for design and construction are attached and it is important that you read the report in its entirety. It is a pleasure to provide our services to you and we look forward to further opportunities to assist you on this and other projects. Respectf ily submitted, WHIT R T , INC. r• son H. Folio. P E. GA Registered Engineer #31031 I lol. W4,AwdA i Joseph M. Whitaker President 515126pt WHITAKER LABORATORY, INC. TABLE OF CONTENTS APPENDIX I SITE & BORING LOCATION PLANS APPENDIX II BORING RECORDS APPENDIX III SEISMIC SPECTRIAL PARAMETERS APPENDIX IV IMPORTANT GENERAL NOTES WHITAKER LABORATORY, INC. Start Page I. INTRODUCTION / SCOPE 1 II. EXECUTIVE SUMMARY 2 III. PROJECT INFORMATION & DESCRIPTION 2 IV. SITE LOCATION & DESCRIPTION 3 V. AREA AND SITE GEOLOGY 3 VI. TEST BORINGS AND SUBSURFACE CONDITIONS 4 VII. GROUNDWATER TABLE 5 VIII. SEISMIC SITE CLASSIFICATION AND COEFFICIENTS 5 IX. EARTHWORK AND FOUNDATION DESIGN CONSIDERATION 6 X. SITE WORK RECOMMENDATIONS 7 XI. PAVEMENT RECOMMENDATIONS 9 XII. QUALITY CONTROL AND TESTING 12 XIII. QUALIFICATIONS OF REPORT 13 APPENDIX I SITE & BORING LOCATION PLANS APPENDIX II BORING RECORDS APPENDIX III SEISMIC SPECTRIAL PARAMETERS APPENDIX IV IMPORTANT GENERAL NOTES WHITAKER LABORATORY, INC. Tybee Marine Science Tybee Island Marine Science Building, Tybee Island, GA Whitaker Laboratory, Inc. Geotechnical Investigation REPORT OF GEOTECHNICAL INVESTIGATION Proposed Tybee Island Marine Science Building North Beach, Tybee Island, GA I. INTRODUCTION / SCOPE WHITAKER LABORATORY, INC. has completed this field investigation of the surface and subsurface conditions at this site. The preliminary conditions found, and how those conditions could affect the design and construction of foundations for the structures planned, form the basis for this report. Regardless of the thoroughness of any geotechnical investigation, there are limitations, and deviations from the conditions found in this investigation could be subsequently disclosed. We recommend that this report be provided to all parties involved in the planned development to include but not necessarily limited to the Owner, Architect, Design Engineers, General Contractor and sub -contractors. Unanticipated circumstances often arise during sitework, earthwork and foundation construction. Accordingly, we recommend that our firm be retained to provide the construction surveillance, inspection, and testing on the project, thereby being readily available to assist in the evaluation of any conditions encountered that differ from those anticipated. The site is located at the North Beach public beach access area off Meddin Drive on Tybee Island, GA. We understand a new Marine Science building structure and associated pavements are planned for construction on this site. In an effort to evaluate subsurface soil conditions and their impact on the design and construction of the planned new structure and pavements, two soil test borings and four auger borings were performed. Borings were advanced within the planned construction areas to depths ranging from 5 to 30 feet below the ground surface. Please note that this evaluation only applies to the foundations and pavements planned for construction. This evaluation does not apply to any future improvements, which may be made to the site. In particular, if at any time should additional fill be placed, adjacent to or nearby the structures referenced in this report, additional geotechnical borings and a follow up geotechnical analysis will be required. Standard billing rates will apply for this work. WHITAKER LABORATORY, INC. Page 1 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation II. EXECUTIVE SUMMARY The following recommendations shall be considered a summary of the recommendations contained within this report and utilized as such. This report shall be read in its entirety. Foundations: We were informed by Kern Engineering that this site does not reside within a velocity zone. Therefore, the subject building site can be made suitable for construction of the planned structure, utilizing shallow spread footing foundations (with normal bearing elevations for footings below finished grade) if the following are achieved and/or are acceptable to the owner and/or design of the structure: Our foundation loading & site grading assumptions are not exceeded, Liquefaction induced settlements are not of concern to the owner or structural designer, and • Site preparation and foundation design are in accordance with the recommendations of this report. At any time, we will be glad to discuss the contents of this report. This includes insuring that you fully consider potential problems for design and construction procedures in respect to interpretations of the data. III. PROJECT INFORMATION & DESCRIPTION We have not been provided foundation loads for the buildings, however for the purpose of this report we will assume that foundation loads will not exceed 100 kips for columns. We will further assume that site grades will not be raised more than 18 inches above existing ground surface elevations to achieve finished grade elevations for slabs -on - grade. Item Description Proposed Improvements Building Structure Finished floor elevation for slabs- Assume maximum 18 inches above existing on -grade grade Maximum Foundation loads Assume 100 kips for columns Maximum Floor Loads for slabs- Assume 100 pounds per square foot on -grade Maximum allowable settlement Assume 1 inch overall and Y2 inch differential Above information was assumed by Whitaker Laboratory, Inc. WHITAKER LABORATORY, INC. Page 2 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation If our assumptions are incorrect, we should be contacted immediately, provided the correct information and allowed an opportunity to change and/or modify the recommendations contained within this report if necessary. IV. SITE LOCATION & DESCRIPTION Item Description Location North Beach, Tybee Island, GA Existing Structures Nearby — Tybee Museum, North Beach Grill & Bathrooms Current ground cover Gravel/shell parking lot Existing topography Generally flat At the time of our site visit, the site consisted of an open parking lot area near the existing Tybee Museum and North Beach Grill. The site and boring locations on the site were accessible and the near surface soils were stable to our truck mounted drilling equipment. The soil test borings were advanced within the planned construction area extending to depths reaching 30 feet each below the ground surface. Auger borings were advanced within planned paved areas extending to depths reaching 5 feet each below the ground surface. V. AREA GEOLOGY The site is located on Tybee Island in Chatham County, Georgia. Tybee Island is one of the coastal barrier islands along the Atlantic Ocean coastline. The entire string of barrier islands along the southeastern U.S. coast serve as a transition zone between the mainland and the ocean. All of these islands are in a continuing state of geologic and location instability. In the time frame that we build and utilize structures, the island's overall geologic stability would not affect planning for this project. This overall project area lies near the eastern edge of the South Atlantic Coastal Plain. In South Carolina and Georgia, this broad, gently sloping region extends southeastward from the Fall Line (Chesterfield - Columbia - Augusta - Macon - Columbus) to the Atlantic Ocean. The soils encountered are sedimentary in origin, and consist of layered marine deposits of sands, silts, and clays. These deposits have since been subjected to successive erosion and re -deposition, by fluctuations of sea levels, storm tides, and winds. Many of the surface sands are the result of depositional forces along ancient beaches, which formed during the changing shoreline and river conditions. Intermittent deposits of shells occur within the strata at irregular intervals. The surface soils in a majority of this Coastal Plain area were deposited during the Pleistocene Era, however surface soils near the coast are likely of the Holocene Era. WHITAKER LABORATORY, INC. Page 3 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation VI. TEST BORINGS AND SUBSURFACE CONDITIONS The field exploration to determine the characteristics of the subsurface materials included a reconnaissance of the project site, and the drilling of exploratory borings. Standard penetration test borings were performed using rotary head drilling equipment and advancing hollow stem augers. Sampling and Standard Penetration Testing, (SPT), was performed in accordance with ASTM D-1586. SPT samples were taken at 2.5 foot intervals of depth for the first 10 feet, and at 5.0 foot intervals thereafter. Standard Penetration testing is done with a 140 pound hammer falling 30 -inches and a two inch diameter sampling spoon. Results of Standard Penetration Testing (SPT N values) provide an indication of the relative consistency, density and in-situ strengths of the tested soils. Soil samples from SPT testing and from the auger cuttings have been used for identification and visual classification. The subsurface stratification and the profile as presented in the boring logs, represent approximate boundary lines between the strata and materials encountered. These boundary lines are usually gradual and not clearly defined, and it is sometimes difficult to record changes in stratification precisely. It should be noted that underlying soil conditions can, and do, vary considerably within short lateral distances. It is possible that conditions may be revealed between boring locations that are different from those found by our borings and used for our analysis. The approximate locations of the borings are shown on the attached BORING LOCATION PLAN. Our drilling crews, based on landmarks and features available at the time of drilling, have estimated the locations of the borings in the field. If the precise location of the boreholes is critical, this can be determined by employing a land surveying firm to plot the true locations. Such survey should be completed promptly and before any disturbance to the area has occurred. If desired, Whitaker Laboratory, Inc. will be glad to coordinate surveying arrangements for an additional fee. Below approximately 12 inches of sand/stone mix, the subsurface soils on this site predominately consist of loose to dense sands (SP and SP -SM) extending to the termination depth of the deepest boring at 30 feet below the ground surface. The above description of the subsurface profile should be considered a general description intended to highlight the major strata encountered. More detailed profiles can be observed within the attached boring logs. Please note that boring logs are only representative of their location. Stratification transitions should be expected to occur outside and between boring locations. Taking into account that sampling was not performed on a continuous basis in the SPT borings, lines drawn representing elevations of stratification changes shown on the SPT boring logs were estimated. WHITAKER LABORATORY, INC. Page 4 of 14 Tybee Marine Science Tybee Island Marine Science Building, Tybee Island, GA VII. GROUNDWATER TABLE Whitaker Laboratory, Inc. Geotechnical Investigation The apparent groundwater table was estimated at each boring location at the time of boring. Groundwater levels were estimated to reside 4 '/2 to 5 feet below the ground surface at the time of boring. The groundwater elevation can be expected to fluctuate with the tide, season of the year, surrounding ground surface conditions, and with recent rainfall amounts. Thus, groundwater elevations shown on the boring logs should be considered valid only for the time and date of observation. We have addressed groundwater concerns within the earthwork and foundation design considerations section of this report. Hydraulic loading rate of near surface soils on this site was evaluated at one location utilizing an Aardvark permeameter. Based upon results of the Aardvark permeameter, a hydraulic loading rate of 1.37 minutes per inch was measured. Testing was performed at a depth of 18 to 24 inches below the existing ground surface elevation. We have identified the test location as P1 on the attached boring location plan. We have also attached the data sheet for your reference within Appendix IV of this report. Whitaker recommends utilizing an appropriate factor of safety to this value prior to utilizing in the site design. Vlll. SEISMIC SITE CLASSIFICATION AND COEFFICIENTS Liquefaction Potential: Whitaker Laboratory, Inc. performed a liquefaction analysis on the soils encountered within soil test boring B-1. Liquefaction typically occurs when very loose to loose non- cohesive soils encountered below the groundwater table experience a significant loss of shear strength due to the increase in porewater pressure resulting from seismic vibrations. The design earthquake utilized in our analysis (Charleston, SC earthquake with magnitude 7.3 and a 2% probability of exceedance in 50 years) yielded peak horizontal ground surface accelerations of 0.25g on this site. Based upon the design earthquake and characteristics of subsurface soils, the liquefaction analysis indicated that the encountered sand stratifications present below the groundwater table have potential to liquefy during the design seismic event. The amount of settlement estimated during and shortly after a seismic event of this magnitude approximated 2 inches. Settlements of this magnitude could cause damage to the structure. If the risk of anticipated settlements due to liquefaction are unacceptable to the owner, extensive ground modification would need to be performed on the liquefiable soil stratums or supporting the structure on pile foundation systems bearing below the potentially liquefiable soil zones would be required. Whitaker Laboratory should be contacted if this risk is unacceptable. Additional evaluation will be required to provide foundation recommendations capable of guarding the structure against liquefaction induced settlements. WHITAKER LABORATORY, INC. Page 5 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation Seismic Parameters: Assuming the structure has a period of vibration under 0.5 second and disregarding liquefaction potential, this site would be defined as a Site Class "D". The classification is determined by average soil properties in the top 100 feet of the soil profile, including standard penetration test N values, shear wave velocities, in-situ shear strengths and moisture contents, as specified by IBC 2012/2015 and ASCE 7-10. Sr, = 0.335 S1 = 0.126 SMS = 0.513 SM1 = 0.289 SIDS = 0.342 SDI = 0.193 A summary report is attached in Appendix III of this report. If the period of vibration for the planned structure is in excess of 0.5 second or the size and design of this structure justifies additional investigation, a Site Specific Geotechnical Investigation and dynamic site response analysis shall be performed. Our firm has the ability to provide our clients such testing and evaluation, and we will be available to discuss the cost, and potential benefit, if any, of such if you desire. IX. EARTHWORK AND FOUNDATION DESIGN CONSIDERATIONS The subject building site can be made suitable for construction of the planned structure, utilizing shallow spread footing foundations if our foundation loading & site grading assumptions are not exceeded, liquefaction induced settlements are not of concern to the owner or structural designer and when site preparation and foundation design are in accordance with the recommendations of this report. All exposed subgrade soils shall be compacted in-place to 95% ASTM D-1557, inspected, tested and approved by Whitaker Laboratory personnel prior to backfill or fill placement begins to achieve finished subgrade elevations on the site. Backfill and/or fill material should consist of coarse-grained soil classified as SW, SP, SM, or SM -SP with a maximum of 15% passing a #200 sieve. • After all fill/backfill has been placed, footings can be excavated. Bottom of footing excavations should be thoroughly compacted to meet or exceed 95% of the soils modified proctor maximum dry density in accordance with ASTM -D-1557. WHITAKER LABORATORY, INC. Page 6 of 14 Tybee Marine Science Tybee Island Marine Science Building, Tybee Island, GA Whitaker Laboratory, Inc. Geotechnical Investigation Footing inspections shall be conducted by performing dynamic cone penetrometer testing within bottom of footing excavations. Subsurface bearing soils deemed unsuitable based upon dynamic cone penetrometer testing should be undercut to a competent material and backfilled with an approved material. Please note that the groundwater table was encountered as shallow as 4 %i feet below existing grades. Dewatering techniques may be required during footing construction. Dewatering may need to consist of sump pits with pumps or well points. Being that bottom of footing elevations will likely reside within close proximity to the groundwater table, provisions shall be made for over excavation of footings by approximately one foot and backfilling with #57 stone. This will help with dewatering measures and keeping the excavation dry during placement of footing concrete. Footing construction shall be performed during periods of low tide Once this is accomplished and verified by Whitaker personnel during construction, footings may be designed to bear in compacted #57 stone backfill (or compacted in- place in-situ soil) utilizing bearing pressures of 2000 PSF. Our technicians, prior to placing steel and concrete, shall approve all footing excavations. All footings should have minimum plan dimensions of 24 inches. Bearing elevations for all footings shall reside deep enough below finished grade elevations to meet local building code requirements. We will be pleased to discuss these recommendations with the owner and the site work contractor selected to do the work. We believe it will be beneficial to the project, for the owner and the contractor to have a clear understanding of our recommendations. Prior to construction, all building areas, plus at least 10 feet on each side and all areas to be paved, should be stripped of all vegetation, topsoil and roots stems. Site drainage during construction should be considered prior to this clearing and stripping. Preventing the ponding of storm water is of particular importance. 2 Topsoil, organics, root -mat and other surface materials will likely vary across the site. Individual test borings may not accurately reflect the presence of, or the thickness of such materials due to site variability and/or surfacing clearing to facilitate access for drilling equipment. Site clearing and grubbing, when unsupervised, and particularly in areas of wet soils and times of wet weather, may push organic debris into otherwise stable soils. Undercutting and clearing with a track hoe in lieu of bulldozers can minimize this. WHITAKER LABORATORY, INC. Page 7 of 14 Tybee Marine Science Tybee Island Marine Science Building, Tybee Island, GA Whitaker Laboratory, Inc. Geotechnical Investigation 3. Any stump holes or other depressions should be cleared of loose material and debris, and should then be back-filled with approved fill. The backfill should be placed in 6 -inch thick lifts and compacted to 95% density in accordance with ASTM D-1557. 4. Any existing utilities that underlie the site should be relocated and their trenches back-filled with approved soil. The backfill should be placed in 6 -inch lifts and compacted to 95% density according to ASTM D-1557. 5. Prior to fill placement, the subgrade should be proof rolled with a loaded dump truck to locate unstable or soft areas. Any unstable areas should then be investigated to determine the cause of the instability. If due to unsuitable soils, such as highly organic soils or soft clays, the areas should be undercut to firm soil and replaced with approved fill compacted in 6 -inch lifts to minimum density of 95% in accordance with ASTM D-1557. If the instability is due to excess moisture in otherwise stable soil, the area should be drained and compacted to 95% density. 6 Any fill or backfill required to level or raise the site should be placed in 8 to 10 inch thick, loose lifts and compacted by appropriate compaction equipment to 95% density in accordance with ASTM D-1557. 7 All of the fill and backfill (including utility line backfill) for this project should consist of clean, free draining granular soils. The fill should be free of objectionable roots, clay lumps, organics and other debris. The fill should be readily compactable during placement. Soils classified as SW, SP, SP -SM or SM with a maximum of 15% passing a #200 sieve may be acceptable. Soils with the minus #200 fraction classified as MH, CH, OH, ML, CL or SC may be rejected. Soils with a maximum plasticity index of 25 and a maximum liquid limit 40 may be acceptable for use only beneath building pads which are situated well above the groundwater table with approval from the geotechnical engineer. Soils classified as SC or CL, exhibiting moisture sensitivity, soils with excessive clay content, or excessive moisture should not be used without approval from the geotechnical engineer. Approved sands will also need to be moisture conditioned as necessary to facilitate proper compaction throughout its entire depth. If utility trenches cannot be sufficiently dewatered to readily allow compaction of the specified pipe bedding material, then a class I (ASTM -D-2321) gravel or gravel mixture will be required. WmiTAKER LABORATORY, INC. Page 8 of 14 Tybee Marine Science Tybee Island Marine Science Building, Tybee Island, GA Whitaker Laboratory, Inc. Geotechnical Investigation 8 To assist in reducing moisture beneath the structure, and to reduce the potential for mold growth, the site shall be graded and filled as necessary to direct drainage away from the structure. If sub drains are installed, these alone may not prevent moisture vapor beneath the structure that can cause mold growth. (Also refer to paragraph 10 below). Care must be taken to not place concrete on top of wet soils. For example, if fill or natural soils experience heavy rain, the soils should be properly drained and dried, prior to placement of concrete. Otherwise moisture migration through the slab will occur. 9 Compact all footing excavations and slab subgrades to a minimum density of 95% in accordance with ASTM -D-1557, prior to placement on concrete. The footing excavations, and all prepared slab subgrade, should be maintained in a dry and compacted condition until the concrete is placed. Areas that are softened by water or that are disturbed by construction activity should be re- worked, re -compacted, or appropriately repaired to the required bearing and density. If necessary, stone backfill or other corrective measures may be implemented to stabilize footings. 10 All slabs -on -grade should be supported on a minimum of 4 -inches of granular, free -draining gravel or coarse sand to reduce moisture migration by capillarity. A vapor retarding membrane, overlying this granular base, is recommended to further reduce moisture migration into finished areas of the structure. Note that the use of these measures will not totally prevent moisture under or on top of slabs or beneath structures. (Also refer to paragraph 8 above). 11. Any footing excavations that are directly adjacent to the existing foundations should be done in small increments to avoid undermining them and causing a loss of support to the existing structure. If necessary, the excavations should be sheeted and braced or grouting should stabilize the soil in the immediate area. XI. PAVEMENT RECOMMENDATIONS Subgrade for driveways and parking areas should consist of a minimum of 24 -inches of clean sand subgrade compacted to a density of 95% of its maximum dry density as determined by ASTM -D-1557. Pavement designs should also provide a minimum of 24 -inches separation between the bottom of the base course material and the seasonal high ground water table. Undercutting, re -compacting, and/or replacing of existing surface soils will be required unless subgrade consists of organic free, virgin sandy soils that are proven to be a minimum of 24 -inches thick, 24 -inches above the seasonal high ground water table, compacted to 95% of ASTM D-1557 and passes a proof -roll. Final grades and elevations will determine the extent of any filling, undercutting and backfilling that may be required. WHITAKER LABORATORY, INC. Page 9 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation Due to groundwater residing 4+ feet below existing grades, combined with near surface soil conditions consisting of sandy soils on this site, the in-situ sandy soils can be made suitable for use as pavement subgrade material as long as the in-place sandy soils are compacted for a full 24 -inch depth below bottom of pavement section elevations. In addition, the use of under drains should not be necessary as long as pavement grades are not lowered below existing ground surface elevations. All proof rolling, construction observations, compaction testing of paved areas must be in accordance with the SITE WORK section above. If a rain event of 0.5 inches or more, occurs after initial proof rolling and prior to subsequent placement of base or surface wearing course, the proof roll testing must be repeated just prior to additional work. The below recommended pavement sections should be considered standard and typical for the area. We have not been provided traffic data and/or been instructed to perform CBR testing on subgrade soils, therefore these pavement sections should not be considered a pavement design. The below recommended pavement sections are based upon the assumption that the sandy subgrade soils will yield a minimum CBR value of 8 if compacted to 95% ASTM D-1557 for a full 24 -inch depth. In addition, the below recommended light duty pavement sections should be considered for car traffic areas only. Below recommended heavy duty sections should be utilized for all areas receiving truck traffic (delivery trucks and garbage trucks with 18 -kip axle loads). In addition the heavy duty sections recommended below are for low volume truck traffic (15 to 20 trucks per day). LIGHT DUTY PAVEMENT (CARS & LIGHT TRUCKS) SUBGRADE: Minimum — 24 -inches of drained, compacted, coarse grained soil BASE COURSE: Minimum - 6 -inches of Graded Aggregate Construction SURFACE COURSE: Minimum - 2 -inches of 12.5 mm Superpave HEAVY DUTY PAVEMENT LOADED TRUCKS WITH 18+ kip AXLE LOADS SUBGRADE: Minimum — 24 inches of drained, compacted, coarse grained soil BASE COURSE: Minimum - 8 -inches of Graded Aggregate Construction BINDER COURSE: Minimum - 2 -inches of 19 mm Superpave SURFACE COURSE: Minimum - 2.0 -inches of 9.5 mm Type II Superpave, or Minimum - 2.0 -inches of 12.5 mm Superpave WHITAKER LABORATORY, INC. Page 10 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation In all projects, a minimum mat temperature of 185° F must be maintained through final roller pass. Please note that specifications for the above mentioned base course and surface course can be found under Sections 310, 400, 815 and 828 of the Georgia Department of Transportation State of Georgia Standard Specifications Construction of Transportation Systems, 2001 Edition. The mix design must include 'lime" All testing procedures, pavement densities, void ratios, and all criteria for final pavement approval must be agreed upon by the parties after completion of a rolling pattern or test strip segment. It must also be agreed that the reference to Georgia DOT Specifications shall mean the entirety of the specification. Portions of such Standard State pavement specifications are not stand alone provisions, and must be considered as mutually complementary provisions, to be used in their entirety. Selected portions of the Standard State specifications may be included, only after completion of a rolling pattern or test strip segment, and the agreement of the parties. PORTLAND CEMENT CONCRETE PAVEMENT HEAVY DUTY: 8 -inches of Portland cement concrete with minimum compressive strength of 4000 PSI. LIGHT DLITY: 5 -inches of Portland cement concrete with minimum compressive strength of 4000 PSI. Whitaker Laboratory recommends incorporating a minimum of 4 -inches of graded aggregate base course below the above concrete pavement sections for maintaining a smooth and level surface during placement of the pavement section. Joints must be placed a MAXIMUM spacing in FEET of 2.5 times the pavement thickness in inches, and in no case more distant apart than 15 feet. Pavement Design should include: 19 Requirements to seal all pavement joints to prevent surface water entry into base / subgrade. Such provision should minimize pumping failures at joints. Requirements that pavement sections and panels subject to repetitive braking and/or acceleration should be designed with lug anchors or tie -bars to minimize separation or misalignment at the joints. Provisions for load transfer across construction joints by dowels or other acceptable means. WmiTAKER LABORATORY, INC. Page 11 of 14 Tybee Marine Science Tybee Island Marine Science Building, Tybee Island, GA Whitaker Laboratory, Inc. Geotechnical Investigation In general, the design should follow the recommendations and practices for all components as described in ACI 330.1 and/or ACI 330R as applicable. XII. QUALITY CONTROL ' 'I TESTING Documented inspections and/or testing performed by Whitaker Laboratory personnel, at the following critical milestones during construction, will be required for the recommendations contained within this report to be validated: Earthwork: Perform density testing and proofrolling on all exposed subgrade soil to verify exposed subgrade soils are compacted and stable enough to begin receiving backfill or fill. • Collect sample of proposed backfill and/or fill material, perform laboratory testing and determine suitability for use (approve or disapprove). • During fill placement: Perform density testing on each lift of backfill and/or fill soil. Footings: • Once footings are excavated: Perform inspection on bearing subgrade soils within bottom of footing excavations prior to placement of reinforcing steel or concrete. Footing inspections shall consist of performing DCP testing within footing excavations. DCP testing shall extend to depths reaching 3 feet below bottom of footing elevations or 5 feet below existing grades whichever is deeper below existing grades. Provide recommendations for undercutting and replacement below footings if deemed necessary. At the appropriate time, please contact Whitaker Laboratory, Inc. for budgetary and scheduling purposes for the performance of the above required inspection and testing services. We further offer concrete, asphalt, masonry, and structural steel inspections and testing. Whitaker Laboratory, Inc. also performs observational services for mold mitigation, including observation of installation of vapor retarding membranes, subdrains, overall site drainage, and regularly scheduled observations after construction of site and landscape drainage, and monitoring of humidity and moisture in slabs and basement walls. WHITAKER LABORATORY, INC Page 12 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation XIII. QUALIFICATIONS OF REPORT Any recommendations or opinions offered in this report are based on our interpretation of the data obtained from this investigation. It should be noted that underlying subsurface and soil conditions can, and do, vary considerably within short lateral distances. Regardless of the thoroughness of any subsurface investigation, it is possible that conditions may be revealed between boring locations that are different from those found by our borings and used for our analysis. For this reason, we recommend that the site preparation and foundation construction for this project be monitored closely. If deviations of the soil conditions from those presented in this report appear, we will be glad to furnish any additional analyses and recommendations that may be required. This report was made to investigate subsurface properties of the site and is not intended to serve as a wetlands survey, toxic mold assessment, or environmental site assessment. No effort has been made to define, delineate, or designate any area as wetlands or an area of environmental concern or contamination. Any references to low areas, poorly drained areas, etc. are related to geotechnical applications. Any recommendations regarding drainage and earthwork are made on the basis that such work can be permitted and performed in accordance with the current laws pertaining to wetlands, storm water runoff, and environmental contamination. This report does not attempt to define or represent any FEMA, or otherwise designated, flood, erosion, scour, or other hazardous zones; nor does it presume to reflect that governmental or other authorities will grant approval of the project and issue appropriate permits. WARRANT: WHITAKER LABORATORY, INC. and its professional engineers strive to perform all services in a manner consistent with that level of care and skill ordinarily exercised by members of the engineering profession practicing in the same locality and under similar conditions. No other warranty or representation, expressed or implied, is included or intended in this agreement, in any report, opinion, document, or otherwise. We carry commercial general liability insurance, including completed operations, and professional liability insurance in aggregate amounts deemed adequate, and we comply with the statutory requirements for workmen's compensation insurance. Accordingly, by accepting and relying on the contents of this report, the liability of WHITAKER LABORATORY, INC. and its professional engineers, to the client, owner, or any other party, for any loss or damage, resulting from any cause, including professional acts, errors, omissions, negligence, toxic mold and other environmental claims, breach of warranty or breach of contract, shall not exceed the total compensation received by us for services related to this project; and client will defend, settle, and discharge any claims or allegations of liability for same against us by others. If client desires higher monetary limits of our liability, we will be pleased to discuss such higher limits and the impact on liability and fees. In the event the client makes a claim against us, at law or otherwise, for any alleged act, error, omission, negligence, breach of warranty or WHITAKER LABORATORY, INC, Page 13 of 14 Tybee Marine Science Whitaker Laboratory, Inc. Tybee Island Marine Science Building, Tybee Island, GA Geotechnical Investigation breach of contract, arising from the performance of our services, it is mutually agreed that initially, the client and Whitaker Laboratory, Inc. will attempt to resolve such dispute through direct negotiations between the appropriate representatives of each party. Secondly, if such negotiations are not fully successful, the parties agree to resolve any remaining disputes by formal nonbinding arbitration mediation in accordance with the rules and procedures to be agreed upon by the parties. Mediation is a pre -condition to litigation. The exclusive venue for any disputes relating to Whitaker Laboratory's service shall be in Chatham County, GA. Furthermore, if the client fails to prove such claim, then client shall pay all costs accrued by us in defending ourselves. TITLE: The ownership of opinions, technical ideas, methods and means, drawings, calculations, and other data developed by us during the course of preparing proposals or rendering engineering services remains exclusively with us. It is a condition of this report or proposal that the client agrees not to use the opinions, technical ideas, methods and means, drawings, calculations or any other data for projects or locations, other than those specifically addressed in the report, and that no one other than the client may use this report, without the written permission of WHITAKER LABORATORY, INC. WHITAKER LABORATORY, INC. Page 14 of 14 APPENDIX I SITE & BORING LOCATION PLANS iylor St SITE Tybee Isla rine Chk & Beach Locations Tybee island Light Station And N Mwun North Beach 8v and ON it Fort Scveven ��Ir�•k St Q` ROW Legion 5�e Vicim&4 Map_ f46ee Island Marine science Center tutee North Beach Parking Lot fybee Island, Georgla 0 WHMAKER LABORATORY, INC HA -1 HA -2 HA -3 ~ 71F `� �• 1� v ANT F FI EV B-� MIN 19 0 f � . r --, a - W M MMIC, ~� :I 00W I3orirq Location plan N 1 y6ee Island Marne 5cience Center 1 y6ee North Beach Parkinq I, f46ee 151and, Georqia ALL POMNU LOCArION5 AM AFMOXIMAIE, g ME PA5W ONLY ON FIEW 6511MA1F5, WHYJAKGRLABORA7ORY, INC. APPENDIX II BORING RECORDS Client: Tybee Marine Science Project: Marine Science Center - North Beach Parking Lot Location: Tybee Island, GA SUBSURFACE PROFILE Description SP -SIH Flan, ten sand with some stone SP -SM Very firm to dense, tan medium to fine sand 5 - SP Dense to firm, gray to tan -gray fine sand 1 15 SP -SM Loose to firm, gray medium to fine sand and shell fragments 20- 25 al: End of Borehole 35 Drilled By: Cody Leach Drill Method: H. S. Auger Drill Date: 6/29/15 Boring No. J3-1 Date: 6129/15 Engineer: Folio samplef 0 r Standard Penetration Test a blowsift. a> 0 � m 10 20 30 40 50 80 70 80 90 3 0- 1 20 2 22 5 3 45 = 4 38 10-151 20 5-181 20 81 8 91 18 WHITAKER LABORATORY, INC. 2500 Tremont Road Savannah, GA 31405 Hole Size: 6.5" Datum: Sheet: 1 of 1 Remarks Client: Tybee Marine Science Project: Marine Science Center - North Beach Parking Lot Location: Tybee Island, GA SUBSURFACE PROFILE mDescription 0 Ground SP Loose to very firm, tan fine sand 5 SP 10 Loose to firm, gray fine sand 15 20 SP -SM Firm, gray medium to fine sand and shell fragments 25 Firm, gray rrtedium to fine sand 30• End of Borehole 35 Baring No. B-2 Date: 6/29/15 Engineer: Folio Sample g� a Standard Penetration Test l'- Remarks blows/ft. a� Z 10 20 30 40 50 60 70 80 90 0 1 a 2 17 5 3 29 4 22 10-151 10 5-161 15 71 13 8 1 15 91 17 Drilled By: Cody Leach WHITAKER LABORATORY, Hole Size: 6.5" Drill Method: H. S. Auger INC. Datum: 2500 Tremont Road Drill Date: 6/29/15 Savannah, GA 31405 Sheet: 1 of 1 5" stone AUGER BORING RECORD PROJECT: 9/bee Marine Science Center DATE: 6/29/15 HOLE DEPTH WATER NO. Ft. SOIL DESCRIPTION TABLE CLASS. HA -1 0-1 Tan, fine sand - some atone 5' SP -SM 1-5 Tan, fine sand SP HA -2 0-1 Tan, fine sand - some stone 4.5' SP -SM 1-5 Tan, fine sand SP HA -3 0-0.92 Tan -brown fine sand - some atone 4.5' SP -SM 0.92-5 Tan, fine sand SP HA -4 0-1.08 Tan -brown, fine sand - some stone 5' SP -SM 1.08-5 Tan, fine sand SP APPENDIX III SEISMIC SPECTRIAL PARAMETERS 8181201s Design Maps Summary Report: USES Design Maps Summary Report User -Specified Input Report Title North Beach Bathrooms, Tybee Island, GA Mon lune e, 2015 13:49:24 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available In 2009) Site Coordinates 32.0220N, 80.8440W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III t 3 (RIJ26 i 3z T M N 0 R T -1 It d AV ERICA I A M ma cquest 02915 KgKbWW Sawa Ama enz MP USGS-Provided Output Ss = 0.335 g SMS = 0.513 g Sag = 0.342 g S, = 0.126 g SM, = 0.289 g Sol = 0.193 g For Information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document, MCE„ Response Spectrum 0.54 0.42 0.42 ,a 0.36 A 0.30 N 0.24 o.l z �. 0.06 O.00 -►- -:-: :-�- -�- -� MOO 0.20 0.40 0.60 0.40 L.00 1.20 1.40 1 6o 1.20 2-00 Period, T (srec) Design Response Spectrum 0.36 0.32 0.20 m 0.24 A 0.20 i0 0.16 0.12 0.02 0.04 0.00 0.00 0.20 0.40 GAO 0.20 LAO 1.20 1,40 1.60 1.00 2.00 Period, T (sec) For PGA,,, T„ C.., and CIL values, please yl hllpJ/ehp3-earlhWAe.wr.uspegoWdesignmaps/ Aummary.php7template- miNmal81eti1ude=32022MONIlude=-B0.644&aIWAass- rlskcategory-ClUdlNon, 112 LIQUEFACTION ANALYSIS Tybee Marine Science Center Building Hblo No.wB-1 WaisrDsur -4 5 }t Ground ImWo►7emonr of Riml R 4qJ &%WsbmRm Rb1o7o7sa1lrytl sokomm n 2 01 01M' 10 f 7 I f0 as y�j 0p 304 CSR S bide#a ZOM has Lausuffm ftmow 30 " ay S - 1-97A7 M9Vn1ruds-7.3 Accalaratknag.2tpr sw os mmm Raw LW RAW W4 swo �► 20 117 e 22 117 0 45 118 e 38 11B 4 20 117 4 20 117 4 7 116 a a 115 a IS 117 9 CWNTeeh Cogwsdon Tybra blond, GA Plate A-1 APPENDIX IV IMPORTANT GENERAL NOTES y Q a Cl O O O C7 Q O O cn C) c v� OAC'l� mn+ aai»w+aa�n►�L-I N O M p] �z.if! SSCCVi L6 Lel M Y T - La � a w u� N Z 0° C m L3 Q [q 1� ►i OP �} ��- a N t 7 c E�CJ "M @ m y 0 4 E Qa 16 q - c'� S�=a=��� ° wEa iA yyC ZN 0.0 N O! 1° " r d C+ e•7 D► I� nl of M n y - y U C r p p C A LL TJ �j �t 0 p c7 rN _ X t� c o P r Ir 07 Ol Liz a0 t� to 4 eG Ql 14 Y 47 QS ��.. 11 C v E� mi rnm � ill p C tA7 ` N fi G w O = Ln p x j � @ N � co C4 ? N v N q N 'Q N et N" v AT Cy � LL C_ O Q Q Y Q a Cl O O O C7 Q O O Q 0.7 c��m ay _O d c O > Stl U ap�+ c T - La � a w u� N Z 0° C m L3 Q [q 1� ►i OP �} ��- ry N t 7 c E�CJ "M @ m y 0 4 E Qa c'� S�=a=��� ° wEa c .E of C C@ c ;�� '0 LL oo i1! v }3 f/J p 4 opo8CQ,Q r 0 4 p O r r r r r r m N q1 C Z r 7 r y @ i3 LL 12L ��.. 11 C v E� .Nm, 0. a❑, N oz's 1. c, c�'i v L m e E � C_ w O1. O 4D 0Z 'd *0 n *' Vj E v d' m C Q, � o o r4o IV La SO "Doy T7 r 2 E + Q r4 C L [il C G C Ly L'1 �7 i0 L17 R7 Ol a N flj I ul o " " `- cc �• C _ o �- v► c► ,�, INSAJ s rA Oc$ L o Q c L = Ix C U ro c f• r. I. I. I. 13 c c E c r. n e. 1�0v Q a ¢,@_ c c? E v m "' �a io ao is w C t� Lo to f 4 +' y` u O Q C C O Q Q 0 Q yam�.++{ � N b r h F• m O N II y@ W I @ .� Tj Ol I f I t 7 C— r m C %o a 0 O a Cly b 03 u a O❑ Q i. 12 CL O `=rte Itt-- ° E a r C N N a IO e p Ol 04 S X 7 ;.Z,'Litl w w Cp C m O ❑ O O Q D❑ O Lu ry i!'l r ICl O f1 C] ,� w v lti N L1i Cti C �. Q ~ c z° m m oVo '� �n n�i H ° U)0.•c th C y 7 qq !G @ O isIn Q 4 O Q❑ Q O Q p U O t+ N i"T V u77 vy r N Q III 0 gl p O IL � ria r$ ul I P: fi CL 01° k eA vi a I E yl� GENERAL NOTES The "standard" penetration resistance is an indicatiori of the density of cohesion less soils and of the strength of cohesive soils. The "standard" penotration test Is measured with a 1.4 inch I.D., 2 inch O.D., sampler driven one {1 ) foot with a 140 pound hammer failing 30 inches. REL&ZLLEJ]EN-SlTY-of sni T You Number of Blows Relative Density 0 - 4 Very loose 6-10 Loose 11-20 Firm 21-30 Very firm 31-50 Dense Over 51 Very dense SISI Number of Blows Consistency 0-2 Very soft 3.4 Soft 5-8 Firm 9-15 Stiff 16-30 Very stiff Over 31 Hard While Individual test boring records are considered to be representative of subsurface conditions at the respective boring locations on the dates shown, it is not warranted that they are representative of subsurface conditlons at other locations and times. The subsoil stratification shown on these profiles is not warranted but is estimated based on accepted soil engineering principles and practices and reasonable engineering judgment. Unless notified, samples will be disposed of after 60 days, GROUP MA=ta-1L01VJ L0.NS___SYAafl COARSE-GRAINED SOILS More than 50% retained on No. 200 Sieve" GRAVELS , 5.M'a t1C.-tr.z.Ciritt7��s� tsE fL,z�tiQLirawineL oil No A ePc,n CLEAN GRAVELS GW Well -graded gravels and gravel -sand mixtl am-little-Qr.na finBS GP Poorly graded gravels and gravel -sand _mlxtl�res._lit}l� ot.m.+�nes GRAVELS WITH FINES GM Silty gravels, gravel -sand -silty -mixtures _ GC Clayey gravels, gravel sand clay SANDS — ( 50% fit ccla[-Ef:Cal,(iorl{73 iSS�S�II]_ CLEAN SANDS SW .S.IiSC$ Well graded sand and gravelly sands, little_"" SP Poor graded sands and gravelly sands, -little or. no fines SANDS WITH FINES SM Silty sands, sand -slit mixtures FINE GRAINED SOILS SILTS AND CLAYS 50% or more passes No. 200'Sleve` igi4d 1_imit Soo/ or i -cc ML Inorganic silts, very fine sands, rock - - - — _flour a' CL Inorganic clays of (ow to medium plasticity, gravelly clays, sandy clays, OL Organic silts and organic silty clays of lew -1--A'.r1ty SILTS AND CLAYS LiWlid.LlLniL_iraater tt,an ±SWj MH Inorganic silts, micaceous or dletomaceous fine sands or CH Inorganic clays of high plasticity, OH Organic clays of medium to high HIGHLY Peat, muck and other highly organic `Based on the material passing the 3 in. (75 mm) sieve.