Roberts Civil Engineering, LLC
St. Simons I Savannah I Jacksonville
912-638-9681 Office 912-289-0339 Fax
December 23, 2019
Mr. Downer Davis
City of Tybee Island
Office: 912.472.5033
Mr. Davis,
Based on field observations on 12/21/2019 and discussions with CE Hall Construction,
Roberts Civil Engineering is in agreement that the construction of drainage swales, at 404
9th street, Tybee Island was completed in accordance with the drainage design provided
by Roberts Civil Engineering to Wubbena Architectural Design and Development and
included on the Site Plan, stamped 1/15/2019 and submitted by Wubbena Architectural
Design and Development to the City of Tybee Island.
Please contact me if you have any questions or concerns.
Sincerely,
Jessica Vick
Project Manager
Roberts Civil Engineering
912-298-7006
Cross reference to Book S70 Page 5311"
WIMOW9 a 0161 ZX19 a) 'A W1 WKS 9 1,1oll" to Z!
rA
I'll, ; . ' "I'll, ju de for a oermit from the City of Tybee Island, Georgia
Permit#: 19-oqL30 Property ON,1 i i
Address: 40
PW: 4L)OO57 A40'p-q
Icq'r—
Legal: go+ t
Base Flood Elevation at the site is _T feet (NGVD)
In accordance with the Flood Damage Prevention Ordinance of the City of Tybee Island, Georgia, the Property Owner agrees to the
following:
1s That the enclosed area below the Base Flood Elevation shall be used solely for parking of vehicles, limited storage, or access to the
building, and will never be used for human habitation without first becoming fully compliant with the Flood Damage Prevention
Ordinance in effect at the time of conversion.
2. That all interior walls, ceilings, and floors below the Base Flood Elevation shall be unfinished or constructed of flood -resistant
materials.
3. That mechanical, electrical, or plumbing devices shall not be installed below the Base Flood Elevation.
4. That the walls of the enclosed area below the Base Flood Elevation shall be equipped with at least two vents which permit the
automatic entry and exit of floodwater with total openings of at least one square inch for every square foot of enclosed area below
flood level. The vents shall be on at least two different walls, and the bottoms of the vents shall be no more than one foot above
grade. If located in a V -zone, breakaway walls are required.
S. That the requested structure may be subject to increased premium rates for flood insurance available from the National Flood
Insurance Program due to its location in a Special Flood Hazard Area.
6. That any variation in construction beyond what is permitted shall constitute a violation and be abatable as such.
6Signature perry Owner�
Signature of Property Owner
STATE OF GEORGIA
COUNTY OF CHATHAM
Subscribed to and sworn before me this Lr_ day of
1`Te�tary Public Witness Siknaturc
h
My commission expires: NOTARY PUBLIC
Bryan County, GEORGIA
My Commission Expires 01109/23
ffote.- A Nonronversion Agreement mitst be used whenever an enclosed structure or portion of a structure is built or substantially improved within
* L y u fres proper - ZOO -year ear Flo(,)dplain below the Base Flood Elevation. A Monconversion Agreement must satisfy all of the above conditions and req
recordation in the land records of Chatham County, Georgia.