Loading...
HomeMy Public PortalAboutMILLER AV_916.pdfU.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2022 1 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION R INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Homes of Integrity Construction Co, Inc. A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 916 Miller Avenue City State ZIP Code Tybee Island Georgia 31328 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 104, Ward 3, Tybee Island A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5;" Latitude/Longitude: Lat. 32°0'6.12" Long. -80°50'54.51" Horizontal Datum: ❑ NAD 1927 ® NAD 1983 A6. 'Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. 'Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 806.00 -sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 8 c) Total net area of flood openings in A8.b 9110.00 -sq in d) Engineered flood openings? ® Yes ❑ No A9. For a building with an attached garage: a) ` Square footage of attached garage sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade c) Total net area of flood openings in A9.b sq in d) Engineered flood openings? ❑ Yes ❑ No CTI — FLOOD INSURANCE (FIRM) INFORMATION 1. NFIP Community Name & Community Number B2. County Name B3. State City of Tybee Island 135164 Chatham Georgia 4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 13051 CO213 G 08-16-2018 08-16-2018 AE 9 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9: ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source: 11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6 ELEVATtON CEATIMAIrt OMB No. 1660-0008 Expiration Date: November 30, 2022 FOR INSURANCE COMPANY USE I PORTANT: In these spaces, copy the corresponding information from Section A. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 916 Miller Avenue City State ZIP Code Company NAIC Number Tybee Island Georgia 31328 SECTIO C — BUILDING ELEVATIONINFORMATION N (S VE E IR ) C1. Building elevations are based on: E]Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations —Zones Al—A30, AE, AH, A (with BFE), VE, V1—V30, V (with BFE), AR, AR/A, ARAE, AR/A1—A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. Benchmark Utilized: eGPS Network Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 6.6 ®feet E]meters b) Top of the next higher floor 16.3 ® feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet Elmeters ; d) Attached garage (top of slab) 6.6 ® feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 15.5 x ❑ feet (Describe type of equipment and location in Comments) ❑ meters f) Lowest adjacent (finished) grade next to building (LAG) 6.2 ® feet ❑ meters ' g) Highest adjacent (finished) grade next to building (HAG) 6.4 ® feet E]meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 6.4 ® feet [—]meters SECTION — SURVEYOR, ENGINEER, ORARCHITECT CE TIFIC TI This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. / certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section provided by a licensed land surveyor? ® Yes ElNo E]Check here if attachments. Certifier's Name License Number Alec B. Metzger 30429 Title Savannah Branch Manager T Company Name EMC Engineering Services, Inc. 9 PROFESSI ONAL Address 27 Chatham Center South Drive, Suite A - r City State ZIP Code Savannah Georgia 31405 Signarr� Date Telephone Ext. 08-16-2022 (912) 644-3200 Copy all pages of this Eleva o Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) A8 d:(3) Flood vents are Smart Vent model number 1540-510.600 sq. in total opening. ,See attached ESR -2074 document. (5)Slat walls with 8510 sq. in of total opening. C2 e: AC Unit C2 f: LAG is front left and front right corners of structure. C2 g: HAG rear right corner. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 2 of 6 ELEVATION CE"FICATE, IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 916 Miller Avenue City State ZIP Code Company NAIC Number Tybee Island Georgia 31328 1 SECTION E — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1—E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. El. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is 0 feet D meters F1 above or EJ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is El feet El meters El above or E] below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (seepages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is El feet El meters El above or [-] below the HAG. E3. Attached garage (top of slab) is [] feet E] meters E] above or E] below the HAG. E4.Top of platform of machinery and/or equipment servicing the building is El feet El meters El above or E] below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? E] Yes [:] No 0 Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address city State ZIP Code Signature Date Telephone Comments Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6 ELEVATION OMB No. 1660-0008 Expiration Date: November 30. 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 916 Miller Avenue City State ZIP Code Company NAIC Number Tybee Island Georgia 31328 SECTIO G — COMMUNITY INFORMATION, (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 -G10. In Puerto Rico only, enter meters. " G1. "❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum G9, BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments.._ FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS DMS No. 1660-000$ ELEVATION CERTIFICATE See Instructions for Item A6. Expiration ®ate: November 30, 2022 FEMA Form 086®0®33 (12/19) Replaces all previous editions. Form Page 5 of 6 NG PHOTOGRAPHS OMB No. 1660-0008ELEVATION - CERTIFICATE Continuation Page Expiration Dater November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 916 Miller Avenue City State ZIP Code Company NAIL Number Tybee Island Georgia 31328 If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs with: date taken;"Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View.": When applicable, photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8. a... ammn.+:l.d.3 ,t�tiaia 1 v ll ' +u1 M1pau'wni2 '' • . d,^d'isytw kvlN� YrkNi �4�ihYii "y, 3 " n i h Photo :Three Photo Three Caption Rear View Clear Photo Three ru wt r . r� R� n � � t Photo four Photo Four Caption Left View Clear Photo Four FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 6 of 6 DIVISION: 06 00 00 OPENINGS SECTION: 0B 95 43—VENTS/FOUNDATION FLOOD VENTS ICE -ES I (800) 423-6587 M' (562) 699-0543 I wwwicc-e REPORT HOLDER SMART VENT PRODucT EVALUATION SUBJECT: INC. Reissued 02/202'1 Revised 04/2021. renewal 02/2023, SMART VENT AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540 -520; #1540-521; #1540-510; #1540-511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT SEALING KIT #1540-526 "2014 F?ecipient of Prestigious 'Western States Seismic Policy Council (WSSPC) Award in Excellence" A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be corm°trued as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright e' 2021 ICC Evaluation Service, LLC. All rights reserved. cc 1321 � atw�ullt�rr SEMI E" I'CC-ES EvaluaEvaluation Report ESR-2074 Reissued February 2021 Revised April 2021 This report is subject to renewal February 2023. ww.[ccTees.or f (800) 423-6587 I (562) 699.0543 A Subsidiary of the international Code Councife DIVISION: 08 0'0 00 —OPENING'S Section: 08 95 43—Vents/Foundation Flo td Vents REPORT HOLDER:. SMART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMART VENT® AUTOMATIC FOUNDATION FLOOD VENTS: MODELS #1540-520; #1540-521; #1540-510; #1540- 511; #1540-570; #1540-574; #1540-524; #1540-514 FLOOD VENT S AL1NG KIT #1540-526 1.0 EVALUATION SCOPE. Compliance with the following codes: e 2021, 2018, 2015, 2012, 2009 and 2006 International Building Code° (IBC) sr 2021, 2018, 2015, 2012, 2009 and 2006 International Residential Code° (IRC) • 2021, 2018 International Energy Conservation Code® (IECC) • 2013 Abu Dhabi International Building Code (ADIBC)t tThe ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: 4 Physical operation rr Water flow 2.0 USES The Smart Vent® units are engineered mechanically operated flood vents (FVs) employed to equalize hydrostatic pressure on walls of enclosures subject to rising or falling flood waters. Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: When subjected to rising water, the Smart Vent* FVs internal floats are activated, then pivot open to allow flow in either direction to equalize water level and hydrostatic pressure from one side of the foundation to the other. The FV pivoting door is normally held in the closed position by a buoyant release device. When subjected to rising water, the buoyant release device causes the unit to unlatch, allowing the door to rotate out of the way and allow flow. The water level stabilizes, equalizing the lateral forces. Each unit is fabricated from stainless steel. Smart Vent° Automatic Foundation Flood Vents are available in various models and sizes as described in Table 1. The SmartVENT® Stacking Model #1540-511 and FloodVENT° Stacking Model #1540- 521 units each contain two vertically arranged openings per unit. 3.2 Engineered Opening: The FVs comply with the design principle noted in Section 2.7.2.2 and Secticn 2.7.3 of ASCE/SEI 24-14 [Section 2.6.2.2 of ASCEISEI 24-05 (2012, 2009, 2006 IBC and IRC)] for a maximum rate of rise and fall of 5.0 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCE/SEI 24, Smart Vent FVs must be installed in accordance with Section 4.0. 3.3 Ventilation: The SmartVENT° Model #1540-510 and SmartVENT° Overhead Door Model #1540-514 both have screen covers with t/4 -inch -by -1/4 -inch (6.35 by 6.35 mm) openings, yielding 51 square inches (32 903 mm2) of net free area to supply natural ventilation. The SmartVENT° Stacking Model #1540-511 consists of two Model #1540-510 units in one assembly, and provides 102 square inches (65 806 mm2) of net free area to supply natural ventilation. Other FVs described in this report do not offer natural ventilation. 3.4 Flood Vent Sealing Kit: The Flood Vent Sealing Kit Model #1540-526 is used with SmartVENT° Model #1540-520. It is a Homasote 440 Sound Barrier° (ESR-1374) insert with 21— 2 -inch -by -2 -inch (51 mm x 51 mm) squares cut in it. See Figure 4. 4.0 DESIGN AND INSTALLATION 4.1 SmartVENT° and FloodVENT°: Smar[VENT® and FloodVENT® are designed to be installed into walls or overhead doors of existing or new construction from the exterior side. Installation of the vents must be in accordance with the manufacturer's instructions, the applicable code and this report, Installation dips allow mounting in masonry and concrete walls of any thickness. In order to comply with the engineered opening design principle noted in Section 2.7.2.2 and 2.7.3 of ASCE/SEI 24- 14 [Section 2.6.2.2 of ASCE/SEI 24-05 (2012, 2009, 2006 IBC and IRC)], the Smart Vent° FVs must be installed as follows: • With a minimum of two openings on different sides of each enclosed area. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or airy other attrbutes nor specifically addressed, nor are they to be construed as an endorsement of' the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service. U.C. asp-ess or implied, as to anvfinding or other matter in this report, or as to any product covered by the report. Copyright -^ 2021 ICC Evaluation Service, LLC. All rights reserved. � na Y. i., is ++. ` a ♦:- s � i i'.v 'i _ r....f ■ i. i': Ir a � � �: y � � ► ♦ , ` f a " i x �i i^ f: i i i � FM Y r f i. i '"' f # �.. f f f ri f'. ,� r - f r ' rT �. f i a r k • %. -: ,,. �.. "f f i i. yK i Y." � � s- t.Q _ `: f . f -i if i i i � i f i ,'., r � _ i. i � i1 if ' �. '7 lk � w r 'yp'. I II � fif 1 � + # ����� �„�'�#� ., a ,�. � - - .. s .. � # �Y � � II��II� ...... . . f i f . f f• � � l � ' s � M � Ewsu �..,,��� � � a3 .. N2r`+�4 .Sheik ����"NA ��" � 1 .. , k �u t � . w`a �.}S- ^�m.�3¢4 t Al?43'�(31v+k iYi�E1k3 .�I 'Pmol ESR-2074 I Most Widely Accepted and Trusted Page 3 o f 5 FIGURE 4 —FLOOD VENT SEALING KIT FIGURE 2 —SMART VENT MODEL 1540-520 FIGURE 3 —SMART VENT: SHOWN WITH FLOOD DOOR PIVOTED OPEN ER OR IMES Evaluation Report ESR -2074 CBC and CRC Supplement Reissued February 2021 Revised l 2021 This report is subject to renewal February 2023. .1 . r Subsidiary International Council* DIVISION:9 00 --OPENINGS Section- ars ation Flood Menta REPORT HOLDER: SMART VENT PRODUCTS, INC. EVALUATION SMART VF -NT* AUTOMATIC FOUNDATION : #1640-521; #1540 -510,01540 -511;#1640 - SM; #1 1 11; - 1 a #1540-514 FLOOD 1 SEALING KIT #1 540-Q6 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose o is evaluation report supplementis to"indicate that SmartVen Automatic Foundation Flood Vents, described in ICC -ES evaluation report ESR -2074, have also been evaluated for compliance with codes noted below. Applicable code editions: 2019 Caftmis Building(CBC) For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development ( ) and Division of State Architect (DSA), see Sections 2.1.1 and 2.1.2 below. 2019 Calitomis Residential Code ( ; 2.0 CONCLUSIONS 2.1 The Smart VentO Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation port -20744 complyh 2019 CBCChapter 12, provided the design and installation are in accordance e 2018 International Building CadeP (113C) provisions noted in the evaluation rt and the additional requirements of CBC Chapters 12 and 1 , as applicable. .1.1 The applicable OSHPO Sections and Chapters of the CBC are beyond the scope of this supplement. 2.1.2 DSA: The applicable A Sections and'Chapters of the CBC are beyond the scope of this supplement. 2.2 CRC: The Smart VentO Automatic Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation report ESR -2074, comply with the 2019 vi the design and installation are in accordance ith the 2018 International Residential o ee (IRC) provisions noted in the evaluation report. This supplement expires concurrently with the evaluation report, reissued February 2021 and revised April 2021. ICC-Ey EvoinationReports are riot to be construed as Mrosenting e r or auy other anribures not eneefficalty addressed, nor are they to be canstrued as an endorsement ofthe subject ofthe report or a reconmendwoonfor its nese. Them is no warranty by ICC Evaluation e. LLQ express or iniplia as � to aurfinding or other matter in this reparL or as to anyproduct covered by the report Copyright 0 2021 ICC Evaluation service, LLC. All rights reserved, Pageof 5 ICC-ES Evaluation Report ESR-2074 FBC Supplement Reissued February 2021 vis f 2021 This report is suNed to renewal February 2023. . s — 1 (800) 4234687 1 (562) 699-054.3 A Subsidiary of the International Code Counc#8 DIVISION:1 e ors: 08 95 43—VentstFoundation Flood Vents REPORTHOLDER: SMART VENT PRODUCTS, INC. EVALUATION SUBJECT. AUTOMATICFOUNDATION FLOOD1; -1; 1; 7e 14 FLOOD VENT SEALING KIT #1540-526 1.0 REPORT PURPOSE AND SCOPE Purposes The purpose othis `evaluation report supplement is to indicate that SmartVwPAutornafic Foundation Rood Vents, d i ICevaluation repo ESR-2074, have also been evaluated for compliance with the codes noted below. Applicable code editions: It 2020 Florida Builth Co Building 2020 Florida Building Cod(--Residentiaf 2.0 CONCLUSIONS The Smarty Foundation Rood Vents, described in Sections 2.0 through 7.0 of the evaluation re ESR-2074, comply with the Florida Building Code—Building Code—Buildingand the Flodda Building Codke—Residenflal, provided a designs requirements are determined in accordance h the Floridaildin Code -Building or the Florida Buildings e-Residential, as applicable. The installation requirements noted in ICC-ES evaluation report ESR-2074 for 2018 International Building Cod t the requirements of the Florida uildin Code -Building or the Florida Building Code-Residential, as applicable. Use of the Smart it .o Foundation also been found to be in compliance with theHigh-Velocity Hurricane Zone provisions of the Florida BuildingCode—Building and a Florida Building Code—Residential. For products falling under Florida Rule 61 G20-3, verification that the report holder's quality assurance program is audited by quality a uran entity approved e Florida Building i ion for the type of inspections being conductedis the responsibility of ars approved validation entity or the code official when the report holder does not possess an approval by the Commission). This supplement expires c rrenily with the evaluation report, reissued February 2021 and revised April 2421. 1C•C =ES Ea*etluatton Reports are not tot to be sot ed as reprammg aesthetres or any other affribWas not sgecifecaI4- a essed. nor are they to be coos ed as an ser of rhe pact atf She report or a recommendation for its use. Mere is no via?rantvbvICCEvatuatwnSemee.LLC express or "mWlwA as is to amyfmaling orother matter in this repots or as to anyproduct covered by the report. Copydght 2021 ICC Evaluation Service, I.L.C. All rights reserved. Page 5 of 5