Loading...
HomeMy Public PortalAboutJONES AV_910-EC.pdfU.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008 Federal Emergency Management Agency Expiration Date: November 30, 2022 'National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. SECTION — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number: Snipes Properties, LLC A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 910 Jones Avenue City State ZIP Code Tybee Island Georgia 31328 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lot 53-8, Ward 3, Tybee Island Tax Parcel # 40006 09011 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential A5. latitude/Longitude: Lat.32.00207' Long. -80.84744° Horizontal Datum: ❑ NAD 1927 Z NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 6 A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) 348.00 sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 6 c) Total net area of flood openings in A8.b 1200.00 sq in d) "Engineered flood openings? ® Yes ❑ No A9. For a building with an attached garage: a) Square footage of attached garage N/A sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes ® No CTI — FLOOD INSURANCE (FIRM) INFORMATION 1. NFIP Community Name & Community Number B2. County Name B3. State City of Tybee Island 135164 Chatham Georgia 4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Revised Date 1305160213 G 08-16-2018 08-16-2018 AE 9.0 B10. Indicate the source of the Base Flood Elevation (FE) data or base flood depth entered in Item 69: ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item B9: NGVD 1929 ® NAVD 1888 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes Z No Designation Date: ❑ CBRS ❑ OPA FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 1 of 6 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30, 2022 IMPORTANT: spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt, Unit Suite, and/or Bldg, No.) or P.O. Route and Box No. Policy Number: 910 Jones Avenue city State ZIP Code Company NAIL Number Tybee Island Georgia 31328 S — BUILDING ELEVATIONINFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: `on Drawings* Building Under Construction* N Finished Construction *A new Elevation Certificate will be required n construction of the building is complete. C2. Elevations — Zones Al—A30, AE, AH, A ( ), VE, V1—V30, V (with E), AR, ARIA, ARIAE, Al 0, ARIAH, AWAO." Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Ricoonly, enter meters. Benchmark Utilized: eGPS Vertical Datum: NAVD88 Indicate elevation datum used for the elevations in items a) through h) bel ❑ NGVD 1929 Pg NAVD 1988 Other/Source: Datum used for building elevations must be the same as that used for the ..Check the measurement used. a) Top of bottom floor (including base , crawlspace, or enclosure floor) 7.6 Eg fee meters b) Top of the next higher floor 17-2 Eg feet meters ) Bottom of the lowest horizontal structural memberZones only) / feet meters ) Attached garage (top of stab) /A feet meters e) Lowest elevation of machinery or equipment servicing the building 10.2 feet meters (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) 7.1 Z feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 7.2 feet meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 71 feet meters structural support _ SECTION— SURVEYOR, ENGINEER,C 1TT CERTIFICATION This certification into be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information, I certify that the Information on this Certificate represents my best efforts to interpret the data available. l understand t any false statement may be punishable by fine or imprisonment under 18 U. S. Code, Section 1001. Were latitude and longitude in Section A provided by a licensed land surveyor? Nyes No ❑ Check here if attachments. rtifler's Name License Number .a James Craig Brewer, PLS 3022 RG/ TitleG%ST Professional Land Surveyor Company Name No. 3022 Brewer Land Surveying PROFESSIONAL Address 604 US Highway 80 W SU city State ZIP Code Pooler Georgia 31322 AIG Sign Telephone . J. Craig Brewer 10-2720 (912) 6-2005 Copy all pages i levation Certificate and all attachments r (1) community official, () insurance agent/company, and () building owner. , Comments (in tiding type of equipment andon, r C2(e), if applicable) It er AB engineered o vents are Smart Vent Model 0-570. Data sheets are attached. Item C2e is the out side HVAC equipment pad. FEMA Form 086-M3 (12119) Replaces all previous editions. Form a 2 of 6 ELEVATION CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 910 Jones Avenue City State ZIP Code Company NAIC Number Tybee Island Georgia 31328 CTI — BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE (WITHOUT BFE) For Zones AO and A (without FE), complete Items E1—E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B,and C. For Items E1-4, use natural grade, if available. Check the measurement used. in Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. 2. for Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 1-2 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3: Attached garage (top of slab) is ' ❑ feet ❑ meters ❑ above or ❑ below the 'HAG. ' E4: Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F — PROPERTY OWNER (OR NE REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 3 of 6 OMB No. 1660-0008 ELEVATION CERTIFICATE Expiration Date: November 30, 2022 IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 910 Jones Avenue City State ZIP Code Company NAIC Number Tybee Island Georgia 31328 SECTION G — COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or ), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8—G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from otherdocumentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2 ❑ A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3. ❑ The following information (Items G4—G10) is provided for community floodplain management purposes. G4. Permit Number G5. Date Permit Issued G6. Date Certificate of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) ❑ feet ❑ meters Datum of the building: G9. " BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title Community Name Telephone Signature Date Comments (including type of equipment and location, per C2(e), if applicable) ❑ Check here if attachments. FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 4 of 6 BUILDING PHOTOGRAPHS _OMB No. 1660-0008 CERTIFICATEELEVATION See Instructions for Item A6. Expiration Date: November 30, 2022 FEMA Form 086-0-33 (12(19) Replaces all previous editions. Form Page 5 of 6 BUILDING PHOTOGRAPHS CERTIFICATEELEVATION Continuation Page OMB No. 1660-0008 Expiration Date: November 30, 2022 Replaces all previous editions. IGURE 4 -FLOOD VENT SEAUNG VJT LEMENEEMENNEM ICC-ES Evaluation Report ESR-2074 CSC and CRC Supplement Reissued February21 This report is subject to renewal February 2023, E. . 1 ( (562) 699-0543 A Subsidiaryof the Intemational Code Council' DIVISION: 06 00 00-OPENINGS Section: 00 66 43-Vents/Foundation Flood Vents REPORT SMART VENT PRODUCTS, INC, EVALUATION ECT: SMARTVENTOAUTOMATIC FOUNDATION t. i ; 10; 11; ; 4; 14 FLOOD VENT SEALING 1.0 REPORT PURPOSE AND SCOPE Purpose- The purpose of thisevaluation report supplement is to indicate that Smart Vents Automatic Foundation Flood Vents, described in ICC-ES evaluation report -2074, have also been evaluated for compliance with codes noted below. Applicable code editaon: 2016 Caffibmia Building Code (C5C) 2016 Ceti is ResidentiOl Code (CRC) 2.0 CONCLUSIONS . C: The Smart Vane Automate Foundation Flood Vents, described in Sections 2.0 through 7.0 of the evaluation port ESR- 2074, -2074, mply with 2016 CBC Chapter 12, provided the design and installation ain accordance withthe 2015 International Building CodeP (113C) provisions noted in the evaluation report and the additional requirements of CBC Chapters 12, 16 and 16A; as applicable. 2.2 C The Smart Venn Automatic Foundation Flood Vents, described in Sections 2.0 thr gh 7.0 of the evaluation report ESR- 2074, comply with the 2016 CRC, provided the design and installation are in accordance a 2016 International Residential Coda (IRC) provisions noted in the evaluation report. This supplement expires ncurrently with the evaluation report, reissued February 20214 ICC-F-5 Evaluation Rrpur& are saot da be catsstrued as rqwesmang arsthe#ss or aq omher atod&ars not spM*ftcally addroued nor are the to, be zwoftwed as an endonexcal oftirasy5jectof &e report or a aneaari ` ; fire jo raa There is no umrranty by ICCEvahmdon Service, LLC expvxv or imgalied, oc to gray ng or eem, mayoras This xar as to map act mverod 4'fke report Copyright 0 2021 ICG Evaluation ice. LLC. All lights reserved, Page 4 or 5 ICC -ES Evaluation Report ESR -2074 FBC Supplement Reissued 2021 This report is subject to renewal February 2023. Mffl.l 1 t (t562) 699-0543 A Subsidiary of the intemational Code Council" DIVISION: 08 00 00 ---OPENINGS Section: 05 05 43—Vents/Foundation Flood Vents REPORT ART VENT PRODUCTS, INC. EVALUATION SUBJECT: SMAKrVENrAUTOMAMC FOUNDATION1; 10; #154"11; #1640-570; #1540-574; 2; 1 FLOOD 1. T PURPOSE AND SCOPE Purpose: 'The purpose of this evaluation report supplement is to Indicate that Smart llentO Automatic Foundation Flood Vents, described in ICC -ES evaluation report -2074, have also been evaluated for 'compliance with the codes noted below. Applicable code editions of 2017 Florida Buildi Cods—Building 2017 Florida Building Code—ROSiderWal 2.0 CONCLUSIONS The Smart Vents Automatic Foundation Flood Vents, desedbed in Sections 2.0 through 7.0 of the evaluation report -2074, comply with the Florida Building Code—Buildingand the FRC, provided the design °and installation are in accordance the 2015 International Building Code* previsions noted in the evaluation Use of the Smart VentO Automate F has also been found to be in compliance Wth the High -Velocity Hurricane Zone provisions of the Florida Building Code—Buddingand the Rodde Building Code—Resfdandal. For products falling under Florida Rule 9N-3,verification that the report er's quality assurance program is audited y a quality assurance entity approved by the Florida Building Commission for the type of inspections being conducted to the responsibility of an approved validation entity (or the code official when the report holder does not possess an approval by the Commission. This supplement expires concurrently vAth the evaluation repo - reissued February 2021. ICC -ES sd%atinx Report not io be construed as ra �.rtttxg of r1h# ics or aW aaer amhum not Vecifwally a"*"ett mw are they to be trued as m rmtarsemeyd afthesmyert ofthereponara rel don or- ixr um There is no wrnwu)ahyrdC&duadan&rvice, LLC evressorimplhA ms to any 'ng or other txaxttrr in #his report or as to anypro&hwl covered 6v the repose Copyright* 2021 ICC Evaluation service, LLC. AJI rights Page 5 of FEMA check list (111�_ "? - - Building Permit Number C;1 1 Applicant's Name: ,' Owner's Name: Site Address, Tax#, Parcel#: Address: q 0 Y) if Telephone: Telephone: V.�73 I. All development— Base Flood Ele-iationData Provided: A. The as -built elevation certificate from a registered land surveyor or (L)r Professional engineer has been submitted? No B. The lowest floor elevation is at or above the required lowest floor elevation? Yes r C. Electrical, heating, ventilation, plumbing, air conditioning equipment (including Duct work) and other service facilities are located above BFE or flood proofed? 4;. r No 11. Development in Zone F A. Solid foundation perimeter walls located below BFE: 1. There are at least two2 openings? e or o 2. Square footage of enclosed area subject to flooding 3. Square inches of venting required 4. Square inches per opening (multiply 1 by w) 5. Number of required vents (3 above divided by 4 above) 6. Foundation contains the minimum number of vents? or No 7. The bottom of each opening is no higher than one (1) foot above grade? es r N o 8. Any cover on openings will permit the automatic flow of floodwaters in or No both directions? . Development in Zanes V, VE and VI- (Coastal iHazard Areas). A. Development location complies with all coastal setback requirements? Yes or No B. Structure is securely anchored to pilings or columns and certification by a Registered, professional architect or engineer has been submitted? Yes or No Reviewer's e: Date reviewed: Local i istr tor's Signature: ate: . —1q-2�_ i ee Island 403 Butler Avenue-P.O. Box 2749 Tybee Island, Ga. 31328-2749