Loading...
22 B ElevationsVENDING/ VACUUM ENCLOSURE PLAN 1/4" = 1'-0"1 VENDINGVENDINGVENDING 001 001.2 001.1 9'-9"10'-0"FIN.20'-0" FIN 19'-9" 6"6'-10" M.O.EQ.6'-4"M.O.EQ.3'-2"3'-0"FIN.7'-0" FIN.10'-10 3/4" FIN.8'-4 3/4"FIN.8'-9"FINUNENCLOSED SPACE. OPEN TO EXTERIOR ABOVE 6" CMU WALL W/ CORRUGATED STEEL CLADDING FOR PAINT METAL FRAME WINDOWS AND DOOR WITH TEMPERED GLASS 2X FURRING AND 58" DRYWALL AT VENDING 001 - INSULATED SPACE LOCKING STEEL EQUIPMENT GATE FOR PAINT 6" CMU WALL W/ CORRUGATED STEEL CLADDING FOR PAINT 3 A6.0 4A6.0 5A6.0 6A6.0 VENDING/ VACUUM ENCLOSURE ROOF PLAN 1/4" = 1'-0"2 10'-0"FIN.20'-0" FIN SLOPE 1/4:12 PREFINISHED ALUMINUM COPING TPO LOW-SLOPE ROOF 4" SQUARE GUTTER TO SCUPPER OPEN TO BELOW DOWNSPOUT TO GRADE TIE TO STORM DRAIN SYSTEM 3 A6.0 4A6.0 5A6.0 6A6.0 VENDING/ VACUUM FRONT ELEVATION 1/4" = 1'-0"3 VENDING/ VACUUM RIGHT ELEVATION 1/4" = 1'-0"48'-0"FIN CLG. HT9'-6"T/ COPING9'-6"T/ COPINGSQUARE CORRUGATED BLACK METAL CLADDING TO MATCH WASH TUNNEL. TYP VENDING/ VACUUM REAR ELEVATION 1/4" = 1'-0"5 VENDING/ VACUUM LEFT ELEVATION 1/4" = 1'-0"69'-6"T/ COPING8'-0"FIN CLG. HT7'-6"T/ DOOR HEAD TYP.7'-6"T/ DOOR HEAD TYP.9'-6"T/ COPINGSCUPPER TO 4" SMOOTH ROUND DS 'HIDDEN' METAL LOCKABLE EQUIPMENT GATE METAL AND GLASS DOOR AND WINDOW W/ SAFETY GLASS 1'-8" EQ. 1'-8" EQ.1'-8"EQ.20'-0" ℄ TO ℄ VFY 20'-0" ℄ TO ℄ VFY 20'-0" ℄ TO ℄ VFY 20'-0" ℄ TO ℄ VFY13'-1"T/ VACUUM CANOPYVACUUM CANOPY TYP. ELEVATION 1/4" = 1'-0"76"CURB TYP.12'-1"B/ CANOPY3'-0"T/ MASONRY BASE12" C-CHANEL CANOPY BORDER FOR PAINT CORRUGATED STEEL ROOFING SLOPED FOR DRAINAGE ABOVE SQUARE STEEL CANOPY FRAMING DECORATIVE "X" TRUSS BRACE FOR PAINT BELOW CANOPY FRAMING 8" STEEL I-PROFILE COLUMN COLUMN BASE BOLTED TO CONC. BASE2'-6" 8 A6.0 9A6.0 20'-0" ℄ TO ℄ VFY 20'-0" ℄ TO ℄ VFY 20'-0" ℄ TO ℄ VFY 20'-0" ℄ TO ℄ VFY 19'-8"SLOPE1/4:12SLOPE1/4:1212" C-CHANEL CANOPY BORDER FOR PAINT CORRUGATED STEEL ROOFING SLOPED FOR DRAINAGE ABOVE SQUARE STEEL CANOPY FRAMING OPEN TO BELOWOPEN TO BELOWOPEN TO BELOWOPEN TO BELOWOPEN TO BELOWOPEN TO BELOW 12" C-CHANEL CANOPY BORDER FOR PAINT CONC. BASE BELOW 4" SQUARE GUTTER AND 4" ROUND SMOOTH DOWNSPOUTS DRAIN TO STORM SYSTEM 6'-4"6'-4"6'-4"13'-2"6'-6"VACUUM CANOPY TYP. ROOF PLAN 1/4" = 1'-0"8 7 A6.0 9 A6.0 12" C-CHANEL CANOPY BORDER FOR PAINT CORRUGATED STEEL ROOFING SLOPED FOR DRAINAGE DECORATIVE "X" TRUSS BRACE 8" STEEL I-PROFILE COLUMN COLUMN BASE BOLTED TO CONC. BASE CAST CONC. BASE 4X8 STEEL TUBE FRAMING FOR PAINT - MECHANICAL CONNECTIONS TYP. 11'-8" COLUMN ℄ TO FACE OF WALL VIF 2'-6"3'-0"12'-1"1'-0"6" CURB TYP.6'-4" EQ. 6'-4" EQ. 6'-4" EQ. 19'-8" 6'-6"13'-2"10'-7"10"8"4" SQUARE GUTTER TO 4" ROUND DS, TIE TO STORM DRAIN SYSTEM 121/4 VACUUM CANOPY TYP. SECTION AT WASH TUNNEL 1/4" = 1'-0"9 7 A6.0 8A6.0 E N C O R E PAY CANOPY FRONT ELEVATION 1/4" = 1'-0"10 12" C-CHANEL CANOPY BORDER FOR PAINT CORRUGATED STEEL ROOFING SLOPED FOR DRAINAGE ON 4X8 STEEL TUBE ROOF FRAMING EXTRUDED METAL SIGNAGE BY OTHERS 8" STEEL I-COLUMN FOR PAINT LIMESTONE CAP MASONRY BASE W/ CAR GATES PAY STATION TERMINALS SET IN MASONRY BASE, VFY MANUF. SPECS 6"CURB TYP.12'-11 3/8"5'-11"T/ MASONRY BASE6'-0 3/8"1'-0"63'-8" 3'-4" 13'-6" ℄ TO ℄ 9'-0" DRIVE AISLE 3'-4" 13'-6" ℄ TO ℄ 9'-0" DRIVE AISLE 3'-4" 13'-6" ℄ TO ℄ 9'-0" DRIVE AISLE 3'-4" 13'-6" ℄ TO ℄ 9'-0" DRIVE AISLE 3'-4" Revisions 2. 4. 5. 6. 7. 8. M I K E S H I V E L Y 2319 N CALIFORNIA AVE CHICAGO IL 60647 773 272 0022 mikeshively.com Encore Car WashUS ROUTE 30 AND N. SPANGLER RD.PLAINFIELD, IL 60586Plot Date: 9. 06.22.20 1. I hereby certify that these drawings were prepared in my office, under my direct supervision, and to the best of my knowledge conform with the codes and ordinances of Chicago, Illinois Illinois Licensed Architect License #001.020210 - Expires 11.30.20 3. 10. Zoning Review 06.22.20 A6.0 Accessory Structure Plans, Elevations, Details