Loading...
HomeMy Public PortalAbout09-01-2020 Plan Commission PacketPlan Commission Tuesday, September 01, 2020 7:00 PM Village Boardroom 24401 W. Lockport Street Plainfield, IL 60544 Agenda CALL TO ORDER PLEDGE TO THE FLAG ROLL CALL APPROVAL OF MINUTES Approval of the Minutes of the Plan Commission meeting held on August 18, 2020. 08-18-2020 Plan Commission Minutes.pdf PUBLIC COMMENTS - • Please email public comments to publiccomments@goplainfield.com, please note PUBLIC COMMENTS - PLAN COMMISSION in the email subject line. Comments must be received by Tuesday, September 1, 2020 at 3:00 p.m. • Village Meetings are livestreamed on the Village’s Website - https://plainfield-il.org/pages/agendasmeetings, click “in progress” when available. • Live meetings are broadcast on Comcast Channel 6 and AT&T U-verse Channel 99. DEVELOPMENT REPORT OLD BUSINESS NEW BUSINESS CASE NUMBER: 1889-080620.SU REQUEST: Special Use (Public Hearing) LOCATION: 15905 S. Frederick Street APPLICANT(S): Laura Donahue, Tranquility Massage and Bodywork Inc. Please email public comments to publiccomments@goplainfield.com, please note PUBLIC HEARING COMMENTS - PLAN COMMISSION in the email subject line. Comments must be received by Tuesday, September 1, 2020 at 3:00 p.m. 1 Plan Commission Page - 2 Tranquility Massage & Bodywork Staff Report.pdf CASE NUMBER: 1891-090120.SPR REQUEST: Site Plan Review LOCATION: Lot 2 of Plainfield Business Park (Van Dyke & Depot Drive) APPLICANT(S): Northern Builders, Inc. Steel Service Center Staff Report & Plans.pdf DISCUSSION ADJOURN REMINDERS - September 7th - Village Offices Closed September 15th - Plan Commission at 7:00 p.m. September 21st - Village Board at 7:00 p.m. 2 Plan Commission Record of Minutes Date: August 18, 2020 Location: Village Hall (Zoom Meeting) CALL TO ORDER, PLEDGE, & ROLL CALL Chairman Kiefer called the Plan Commission meeting to order at 7:00 p.m. and led the pledge to the flag. ROLL CALL: Commissioners Heinen, Minnis, Renzi, Seggebruch, Womack, and Chairman Kiefer were present. Commissioner Ruane was absent. OTHERS PRESENT: Jonathan Proulx, Director of Planning; and Jessica Gal, Associate Planner. APPROVAL OF MINUTES The Minutes of the Plan Commission meeting held on August 4, 2020 were approved as presented. PUBLIC COMMENTS No Public Comments received via email. DEVELOPMENT REPORT Mr. Proulx provided updates on the following Planning case: Encore Car Wash, Lake Dr. Annexation, and the Will County Special Use request. OLD BUSINESS NEW BUSINESS 1888-072820.SU 24018 W. Lockport St. The Hair Loft Salon/Studio Ms. Gal the applicants are seeking special use approval to establish a beauty salon, nail salon, and spa at 24018 West Lockport Street in Downtown Plainfield. The property is currently zoned B-5 Traditional Business District and is commonly referred to as “Baci’s” based on the name of its last tenant, an Italian restaurant that closed in 2010. The property is a significant historic structure and is located within the Village’s Downtown Historic District, listed on the National Register of Historic Places. Ms. Gal reviewed the staff report dated August 14, 2020. Ms. Gal concluded Staff believes that the proposed business will fill a downtown vacancy and bring to life a long-term vacant building. Based on the foregoing analysis, prior to public comments and direction from the Plan Commission, staff recommends approval. Chairman Kiefer stated no public comments were received via email. Mr. Proulx confirmed. Chairman Kiefer swore in Jerry Shepich, realtor for applicant. Mr. Shepich added that they have been coordinating with the Fire Department. Commissioner Heinen stated he does not have any comments and is glad to see the building being used again. Commissioner Minnis asked if adding handicapped accessibility to the entrance of the building will affect the historical component of the building. Chairman Kiefer swore in Jaime Gascon, architect. Ms. Gal stated it must be incorporated to meet code, so there is more flexibility to meet ADA accessibility. Ms. Gal further stated there will be some renovation that can be reviewed administratively but a review by the HPC 3 Plan Commission Minutes August 18, 2020 Page 2 of 3 may be required depending on the changes. Mr. Gascon indicated he believes that there is an existing Lula lift in the front of the building. Commissioner Minnis asked if the interior improvements will be brought up to current code. Mr. Shepich confirmed. Commissioner Minnis asked staff to explain the parking that is parallel to the building. Ms. Gal explained that there is a drive aisle but no “marked” parking. Ms. Gal indicated that the applicant will need reserved handicapped parking there since it is closest to the ADA entrance. Commissioner Minnis asked if the owner will be keeping their current location, too. Mr. Shepich stated the applicant will be moving the business and not retaining their current site. Commissioner Renzi asked for clarification if the three parking spaces adjacent to the building will be striped. Ms. Gal stated it will be at the applicant’s discretion if they want to use those as parking spaces. Ms. Gal added that staff’s role was to identify the numbers of parking spaces that would be on site, which staff estimated there could be a max of 10 parking spaces of site. Commissioner Renzi is concerned about the egress/ingress with the adjacent property. Chairman Kiefer indicated that the afore mentioned parking spaces would not be required to meet parking code. Ms. Gal Confirmed. Mr. Shepich explained the egress/ingress and added that there is a parking space in the rear of the building that could accommodate an ADA parking space. Commissioner Renzi asked if there would be enough room for two lanes of traffic in the egress/ingress. Mr. Shepich confirmed. Commissioner Renzi asked staff if the parking will be reviewed by the Village Engineering Department. Ms. Gal confirmed. Commissioner Renzi is concerned that there won’t be enough more for emergency vehicles and one or two lanes of traffic if the applicant utilizes the parking spaces on the westside of the building. Mr. Shepich confirmed that with parking traffic will still be able to access the site but will need to verify with the Fire Department regarding emergency vehicle. Commissioner Seggebruch stated an accessible entrance would need to be added to the rear of the building to have ADA parking in the rear. Commissioner Seggebruch asked if the applicant will be adding services, since the building is much large then their current space. Chairman Kiefer swore in Karen Garcia and Miguel Hurtado, applicants. Ms. Garcia stated she will be adding employees and services which include nail services, facials, and massage. Commissioner Womack stated he agrees with the other commissioner’s comments. Chairman Kiefer is happy to see the building being repurposed. Commissioner Renzi made a motion adopt the findings of fact of staff as the findings of fact of the Plan Commission and, furthermore, recommend approval of the special use permit for personal services that include a beauty salon, nail salon, and spa services for the business commonly known as The Loft Hair Salon, located at 24018 West Lockport Street, subject to the following two (2) stipulations: 1. Compliance with the requirements of the Village Engineer; 2. Compliance with the requirements of the Plainfield Fire Protection District Second by Commissioner Seggebruch. Vote by roll call: Heinen, yes; Minnis, yes; Womack, yes; Seggebruch, yes; Renzi, yes; Kiefer, yes. Motion carried 6-0. 4 Plan Commission Minutes August 18, 2020 Page 3 of 3 DISCUSSION No discussion. Chairman Kiefer read the reminders. ADJOURN Plan Commission meeting adjourned at 7:30 p.m. Respectfully submitted by Tracey Erickson Tracey Erickson Recording Secretary 5 6 7 8 9 15905 S. Frederick Street - Aerial Map EagleView: Pictometry, Sources: Esri, HERE, Garmin, Intermap, increment P Corp., GEBCO, USGS, FAO, NPS, NRCAN, GeoBase, IGN, Kadaster NL, Village Address Points Parcels Subdivisions 8/25/2020, 9:42:36 AM 0 0.01 0.030.01 mi 0 0.03 0.060.01 km 1:1,500 Plainfield Staff County of Will, Esri, HERE, Garmin, INCREMENT P, USGS, EPA, USDA | EagleView: Pictometry | Plainfield GIS | Plainfield GIS | Will County GIS | NPMS National Repository |10 7ti;��M: t1/ DATE:SUBJECT: CASE NUMBER : REQUEST: � PLAN COMMISSION JAKE MELROSE, AICP, E.D. MANAGER SEPTEMBER 1, 2020 STEEL SERVICE CENTER PLAN 1891-082720.SPR Site Plan Review Michael P. Collins PRESIDENT Michelle Gibas VILLAGE CLERK TRUSTEES Harry Benton Margie Bonuchi Kevin M. Calkins Patricia T. Kalkanis Cally Larson Brian W ojowski LOCATION: APPLICANTS: Lot 2 of Plainfield Business Park (Van Dyke & Depot Drive) Northern Builders, Inc. CURRENT ZONING: COMP. PLAN: DISCUSSION 1-1 Light Industrial District (PUD) Mixed Use The petitioner, Northern Builders, Inc., is proposing to construct a 65,120 square foot steel service center user with office/warehouse located in the Plainfield Small Business Park at the NEC of Persons Parkway and Wood Farm Road. The project site is currently zoned 1-1 Industrial District P.U.D. (rezoned to 1-1 in 2017) and the proposed light industrial use is considered a permitted use in the subject zoning district. Existing Conditions/Site Context The existing subject area is located on the southwest side of the existing Lot 2 in the Plainfield Small Business Park south of the Pace Park N' Ride and is zoned 1-1 Industrial District P.U.D. The adjacent land-uses, zoning and functional street classifications are identified below: North: Pace Park N' Ride (11 Industrial) East: Plainfield Small Business Park Future Development Area (11 Industrial) South: Plainfield Small Business Park Fulure Development Area (11 Industrial) West: R-4 Multiple Family Residential District (Patriot Square) SITE PLAN ANALYSIS The proposed steel service center facility is located on 3.64 acres of the Plainfield Small Business Park at the NEC of Wood Farm Road and Persons Parkway of the business park. The proposed user is a steel service center that receives steel and rebundles the steel for their clients and then delivers the product. They do not manufacture or reprocess steel. The steel service center does cut some steel from time-to-time for client specifications. The user is a family­ owned operation with 15-20 employees currently operating in Broadview, IL. 24401 W. Lockport Street Plainfield, IL 60544 Phone (815) 436-7093 Fax (815) 436-1950 Web www.plainfield-il.org 11 12 13 14 15 DOWDEN DESIGN GROUPP.O. BOX 415, LIBERTYVILLE, IL, 60048LANDSCAPEPLANDEPOT DRIVE PLAINFIELD, ILLINOISREVISIONS:DOWDENDESIGNGROUP.COM PHONE: (847) 362~1254DATE: 08.25.20SCALE: 1"=10'DRAWN: CJDPERLOW STEELL102not to scalePLANTING MIX:75% EXISTING SOIL25% MUSHROOM COMPOSTSCARIFY SIDES OF PLANTINGPIT IF GLAZED OR DRIEDPLANTING PIT DIAMETER(2) TIMES ROOT BALL DIAMETERSET ROOT BALL 2"ABOVE FINISH GRADE3" DEPTH SHREDDED HARDWOOD BARK MULCH KEEP 6" FROM TRUNK OR ROOT FLAREPLACE ROOT BALL ON STABLE SUBGRADECOMPACT EXCAVATED SOIL AROUND ROOTBALL BASE TO STABILIZEDECIDUOUS TREE PLANTING DETAILnot to scaleFORM SAUCER WITH 3" CONTINUOUS RIMUNDISTURBEDSUBGRADE3" MULCH RINGSOIL BACKFILL WITH MIXWATER & TAMP TOREMOVE AIR POCKETSSHRUB PLANTING DETAILnot to scale3" DEPTH SHREDDEDHARDWOOD BARK MULCHKEEP 6" FROM TRUNKOR ROOT FLAREPLANTING PIT DIAMETER(2) TIMES ROOT BALL DIAMETERSET ROOT BALL 2" ABOVE FINISH GRADEREMOVE WIRE BASKET FROMTOP OF ROOT BALLPLANTING MIX:75% EXISTING SOIL25% MUSHROOM COMPOSTSCARIFY SIDES OF PLANTINGPIT IF GLAZED OR DRIEDPLACE ROOT BALL ON STABLE SUBGRADECOMPACT EXCAVATED SOIL AROUND ROOTBASE TO STABILIZEEVERGREEN TREE PLANTING DETAIL(3) 30" VDBM(11) #1 CAKF(3) 36" HPL(3) 24" WFB(10) 24" BGV(2) 2.5" GTS(3) 24" WFB(15) #1 HHR(9) #1 NFWL(9) #1 NFWL(10) #1 HHR(3) 24" WFB(7) 30" FOSOFFICE(1) 6' AGAB(13) #1 CAKF(12) 24" BGV(1) 2.5" GTSSODSODSODSODSOD LIMIT(3) 6' PA05102030SCALE: 1"=10'TURFTURFTURFPREMIUM BLUEGRASS MIX 4-5 LBS PER 1,000 SF 20% MIDNIGHT KENTUCKY BLUEGRASS 20% DENIM KENTUCKY BLUEGRASS 20% LANGARA KENTUCKY BLUEGRASS 20% BLUESTAR KENTUCKY BLUEGRASS 10% PRIZM PERENNIAL RYEGRASS 10% SUNSHINE PERENNIAL RYEGRASS 16 DRIVE INDRIVE IND.I.D.D.I.D.OFF.10 TON CRANE10 TONCRANEDOWDEN DESIGN GROUPP.O. BOX 415, LIBERTYVILLE, IL, 60048LANDSCAPEPLANDEPOT DRIVE PLAINFIELD, ILLINOISREVISIONS:DOWDENDESIGNGROUP.COM PHONE: (847) 362~1254PERLOW STEELDATE: 08.25.20SCALE: 1"=40'DRAWN: CJDL101(3) 2.5" PAMC(5) 6' PA(3) 6' SRIS(3) 6' PGD(3) 2.5" ARR(21) 30" POSW(3) 2.5" LTEC(3) 6' CMGG(3) 6' AGAB(3) 2.5" QR(9) 6' PGD(3) 2.5" AFM(5) 6' PM(5) 6' PMLOT 465,120 S.F. OFFICE/WAREHOUSEPERSONS PARKWAYS. WOOD FARM ROADDEPOT DRIVEPLEASE SEE LANDSCAPE PLAN L102FOR OFFICE PLANTING DESIGN(3) 2.5" UMGFUTUREEXPANSION20,000 S.F.PLANT LIST Qty. Common Name Botanical Name Size Remarks Key 3 Marmo Maple Acer freemanii ‘Marmo’ 2.5” B&B AFM 3 Redpointe Maple Acer rubrum ‘Redpointe’ 2.5” B&B ARR 3 Skyline Locust Gleditsia triacanthos ‘Skyline’ 2.5” B&B GTS 3 Emerald City Tulip Tree Liriodendron tulipifera ‘Emerald City’ 2.5” B&B LTEC 3 Exclamation London Planetree Platanus acerifolia ‘Morton Circle’ 2.5” B&B PAMC 3 Northern Red Oak Quercus rubra 2.5” B&B QR 3 Triumph Elm Ulmus ‘Morton Glossy’ 2.5” B&B UMG 4 Autumn Brilliance Serviceberry Amelanchier grandiflora 6’ B&B AGAB 3 Golden Glory Cornelian Cherry Cornus mas ‘Golden Glory 6’ B&B CMGG 3 Ivory Silk Japanese Tree Lilac Syringa reticulata ‘Ivory Silk’ 6’ B&B SRIS 8 Norway Spruce Picea abies 6’ B&B PA 12 Black Hills Spruce Picea glauca ‘Densata’ 6’ B&B PGD 10 Douglas Fir Pseudotsuga menziesii 6’ B&B PM 22 Green Velvet Boxwood Buxus ‘Green Velvet’ 24” Cont. BGV 7 Sunrise Forsythia Forsythia ovata ‘Sunrise’ 30” Cont. FOS 3 Limelight Hydrangea Hydrangea paniculata ‘Limelight’ 36” Cont. HPL 21 Summer Wine Purpleleaf Ninebark Physocarpus opulifolius ‘Summer Wine’ 30” Cont. POSW 3 Blue Muffin Viburnum Viburnum dentatum ‘Blue Muffin’ 30” Cont. VDBM 9 Spilled Wine Weigela Weigela florida ‘Bokraspiwi’ 24” Cont. WFB 24 Karl Foerster Reed Grass Calamagrostis acutiflora ‘Karl Foerster’ #1 Pots CAKF 25 Happy Returns Daylily Hemerocallis ‘Happy Returns’ #1 Pots HHR 18 Walker’s Low Catmint’ Nepeta faassenii ‘Walker’s Low’ #1 Pots NFWL 0 20 40 80120SCALE: 1"=40'NOTES:NOTES:NOTES:NOTES: 1) THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL PLANT MATERIALS IN QUANTITIES SUFFICIENT TO COMPLETE PLANTING AS SHOWN ON THE DRAWING. ALL PLANTS SHALL COMPLY WITH THE REQUIREMENTS PF THE CURRENT AMERICAN STANDARD FOR NURSERY STOCK, PUBLISHED BY THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION. PLANTS SHALL MEET SIZE, GENUS, SPECIES AND VARIETY AND BE IN GOOD HEALTH, FREE OF INSECTS, DISEASES, OR DEFECTS. NO “PARK GRADE” MATERIAL SHALL BE ACCEPTED. TREES NOT EXHIBITING A CENTRAL (OR SINGLE) LEADER WILL BE REJECTED UNLESS CALLED IN THE PLANT LIST AS MULTI-STEM. QUANTITY LISTS ARE SUPPLIED AS A CONVENIENCE. THE LANDSCAPE CONTRACTOR SHALL VERIFY ALL QUANTITIES AND, IN CASE OF DISCREPENCY, THE PLAN SHALL PREVAIL. NO PLANTS ARE TO BE CHANGED OR SUBSTITUTED WITHOUT APPROVAL FROM A REPRESENTATIVE OF JAMES DOWDEN & ASSOCIATES, Inc, 2) ALL PLANTS SHALL BE WATERED DURING THE FIRST 24 HOUR PERIOD FOLLOWING INSTALLATION. A WATERING SCHEDULE MUST BE AGREED UPON WITH THE OWNER (BEFORE PLANTINGS ARE INSTALLED) OF WHOM, WHEN AND HOW PLANT MATERIALS ARE TO BE PROPERLY WATERED. THE LANDSCAPE CONTRACTOR SHALL VERIFY PROPER WATERING IS BEING DONE FOR THE ESTABLISHMENT AND HEALTH OF ALL PLANT MATERIALS. The landscape contractor shall warranty all plant materials for one year from the time of installation and project acceptance. 3) PLANTS SHALL BE BALLED AND BURLAPPED UNLESS OTHERWISE NOTED ON THE LANDSCAPE PLAN. NO ROOT BOUND MATERIAL SHALL BE ACCEPTED AND ALL WRAPPING MATERIALS MADE OF SYNTHETICS OR PLASTICS SHALL BE REMOVED AT THE TIME OF PLANTING. IT IS THE OPTION OF THE LANDSCAPE CONTRACTOR TO ROLL BACK BURLAP FROM THE TOP OF THE ROOT BALL. 4) RECOMMENDED MULCH DEPTH IS THREE INCHES (3”) OF SHREDDED HARDWOOD BARK. THE LANDSCAPE CONTRACTOR SHALL AVOID OVERMULCHING AND THE CREATION OF “MULCH VOLCANOES”. Mulch Beds shall extend a minimum of two feet (2’) beyond the center of a tree or shrub. Mulch must be pulled back at least two inches (2’) from the base of a tree so the base of the trunk and root crown are exposed. 5) Prepare all perennial beds with one cubic yard of garden compost per 100 sf and the compost shall be rototilled to an 8” depth. 6) All plants shall be set plumb. It is the option of the landscape contractor to stake deciduous trees but it is also the responsibility of the landscape contractor to guarantee the plants remain plumb until the end of the guarantee period. 7) Trees shall be installed a minimum of five feet (5’) horizontally from underground electrical feeders, sanitary sewers, sanitary services, water mains, and water services. Trees shall be installed a minimum of ten feet (10’) horizontally from utility structures including, but not limited to, manholes, valve vaults and valve boxes. Shade trees shall be a minimum of ten feet (10’) from all light poles and all shrubs shall be a minimum of three to five feet (3’-5’) from all fire hydrants. 8) The landscape contractor shall locate the existence of all underground utilities prior to starting work. The landscape contractor must also keep the pavement and work areas in neat and orderly condition throughout the construction process. The Landscape contractor shall acquaint himself with. And verify. Working conditions in advance of submitting a proposal. Failure to recognize inherent responsibilities does not relieve the contractor of obligations due to miscalculations. 9) Property owners shall be responsible for maintaining all landscaping shown on the approved plans throughout the life of the development. 10) ALL TURF SHALL BE PREMIUM BLUEGRASS MIX (4-5 LBS/1,000SF) WITH NORTH AMERICAN GREEN DS75, OR EQUIVALENT, EROSION CONTROL BLANKET IN ALL DISTURBED AREAS. TURFTURFTURFTURFTURFTURFTURFTURFTURF17 18 19 40 S. Addison Rd. • Suite 100 • Addison, IL 60101 • P: (630) 543-9059 • F: (630) 543-9077 www.connellyelectric.com SITE LIGHTING FIXTURE SUBMITTAL FOR: PERLOW STEEL NORTHERN BUILDERS INC. 20 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 1 of 8COMMERCIAL OUTDOOR D-Series Size 1 LED Area Luminaire Catalog Number Notes Type Introduction The modern styling of the D-Series is striking yet unobtrusive - making a bold, progressive statement even as it blends seamlessly with its environment. The D-Series distills the benefits of the latest in LED technology into a high performance, high efficacy, long-life luminaire. The outstanding photometric performance results in sites with excellent uniformity, greater pole spacing and lower power density. It is ideal for replacing up to 750W metal halide in pedestrian and area lighting applications with typical energy savings of 65% and expected service life of over 100,000 hours. Hit the Tab key or mouse over the page to see all interactive elements. L H L H1 WW HH2 Ordering Information EXAMPLE: DSX1 LED P7 40K T3M MVOLT SPA NLTAIR2 PIRHN DDBXD DSX1 LED Series LEDs Color temperature Distribution Voltage Mounting DSX1 LED Forward optics P1 P4 1 P7 1 P2 P5 1 P8 P3 P6 1 P9 1 Rotated optics P10 2 P12 2 P11 2 P13 1,2 30K 3000 K 40K 4000 K 50K 5000 K T1S Type I short (Automotive) T2S Type II short T2M Type II medium T3S Type III short T3M Type III medium T4M Type IV medium TFTM Forward throw medium T5VS Type V very short 3 T5S Type V short 3 T5M Type V medium 3 T5W Type V wide 3 BLC Backlight control 4 LCCO Left corner cutoff 4 RCCO Right corner cutoff 4 MVOLT 5 120 6 208 6 240 6 277 6 347 6 480 6 Shipped included SPA Square pole mounting RPA Round pole mounting 7 WBA Wall bracket 3 SPUMBA Square pole universal mounting adaptor 8 RPUMBA Round pole universal mounting adaptor 8 Shipped separately KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish) 9 Specifications EPA:1.01 ft2 (0.09 m2) Length:33” (83.8 cm) Width:13” (33.0 cm) Height H1:7-1/2” (19.0 cm) Height H2:3-1/2” Weight (max):27 lbs (12.2 kg) Control options Other options Finish (required) Shipped installed NLTAIR2 nLight AIR generation 2 enabled 10 PIRHN Network, high/low motion/ambient sensor 11 PER NEMA twist-lock receptacle only (controls ordered separate) 12 PER5 Five-pin receptacle only (controls ordered separate) 12,13 PER7 Seven-pin receptacle only (controls ordered separate) 12,13 DMG 0-10v dimming wires pulled outside fixture (for use with an external control, ordered separately) 14 DS Dual switching 15,16,17 PIR High/low, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 5fc 17,18 PIRH High/low, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 5fc 17,18 PIR1FC3V High/low, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 1fc 17,18 PIRH1FC3V Bi-level, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 1fc 17,18 FAO Field adjustable output 17,19 Shipped installed HS House-side shield 20 SF Single fuse (120, 277, 347V) 6 DF Double fuse (208, 240, 480V) 6 L90 Left rotated optics 2 R90 Right rotated optics 2 HA 50°C ambient operations 1 Shipped separately BS Bird spikes 21 EGS External glare shield DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white 21 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 2 of 8COMMERCIAL OUTDOOR Tenon O.D. Mounting Single Unit 2 @ 180 2 @ 90 3 @ 90 3 @120 4 @ 90 2-3/8"RPA AS3-5 190 AS3-5 280 AS3-5 290 AS3-5 390 AS3-5 320 AS3-5 490 2-7/8"RPA AST25-190 AST25-280 AST25-290 AST25-390 AST25-320 AST25-490 4"RPA AST35-190 AST35-280 AST35-290 AST35-390 AST35-320 AST35-490 Tenon Mounting Slipfitter Drilling Top of Pole 0.563” 2.650” 1.325”0.400”(2 PLCS) Template #8 Ordering Information NOTES 1 HA not available with P4, P5, P6, P7, P9 and P13. 2 P10, P11, P12 or P13 and rotated optics (L90, R90) only available together. 3 Any Type 5 distribution with photocell, is not available with WBA. 4 Not available with HS. 5 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 6 Single fuse (SF) requires 120V, 277V or 347V. Double fuse (DF) requires 208V, 240V or 480V. 7 Suitable for mounting to round poles between 3.5” and 12” diameter. 8 Universal mounting brackets intended for retrofit on existing, pre-drilled poles only. 1.5 G vibration load rating per ANCI C136.31. Only usable when pole’s drill pattern is NOT Lithonia template #8 9 Must order fixture with SPA option. Must be ordered as a separate accessory; see Accessories information. For use with 2-3/8” diameter mast arm (not included). 10 Must be ordered with PIRHN. Sensor cover available only in dark bronze, black, white and natural aluminum colors. 11 Must be ordered with NLTAIR2. For more information on nLight Air 2 visit this link. 12 Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting cap included. 13 If ROAM® node required, it must be ordered and shipped as a separate line item from Acuity Brands Controls. Node with integral dimming. 14 DMG not available with PIRHN, PER5, PER7, PIR, PIRH, PIR1FC3V or PIRH1FC3V, FAO. 15 Provides 50/50fixture operation via (2) independent drivers. Not available with PER, PER5, PER7, PIR or PIRH. Not available P1, P2, P3, P4 or P5. 16 Requires (2) separately switched circuits with isolated neutrol. 17 Reference Controls Option Default settings table on page 4. 18 Reference Motion Sensor table on page 4 to see functionality. 19 Not available with other dimming controls options 20 Not available with BLC, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information. 21 Must be ordered with fixture for factory pre-drilling. 22 Requires luminaire to be specified with PER, PER5 or PER7 option. See Control Option Table on page 4. 23 For retrofit use only. Only usable when pole’s drill pattern is NOT Lithonia template #8 Accessories Ordered and shipped separately. DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 22 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 22 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 22 DSHORT SBK U Shorting cap 22 DSX1HS 30C U House-side shield for P1, P2, P3, P4 and P5 20 DSX1HS 40C U House-side shield for P6 and P7 20 DSX1HS 60C U House-side shield for P8, P9, P10, P11 and P12 20 PUMBA DDBXD U*Square and round pole universal mounting bracket (specify finish) 23 KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish) 9 DSX1EGS (FINISH) U External glare shield For more control options, visit DTL and ROAM online. Options .50 73˚ 12.05 12.476 .50 73˚ 12.05 12.48 HANDHOLE ORIENTATION A Handhole B C D EGS - External Glare Shield Drilling Template Minimum Acceptable Outside Pole Dimension SPA #8 2-7/8” 2-7/8” 3.5”3.5”3”3.5” RPA #8 2-7/8” 2-7/8” 3.5”3.5”3”3.5” SPUMBA #5 2-7/8” 3”4”4”3.5”4” RPUMBA #5 2-7/8” 3.5”5” 5” 3.5”5” Mounting Option Drilling Template Single 2 @ 180 2 @ 90 3 @ 90 3 @ 120 4 @ 90 Head Location Side B Side B & D Side B & C Side B, C & D Round Pole Only Side A, B, C & D Drill Nomenclature #8 DM19AS DM28AS DM29AS DM39AS DM32AS DM49AS 1.75” for aluminum poles 2.75” for other pole types Fixture Quantity & Mounting Configuration Single DM19 2 @ 180 DM28 2 @ 90 DM29 3 @ 90 DM39 3 @ 120 DM32 4 @ 90 DM49 Mounting Type DSX1 LED 1.013 2.025 1.945 3.038 2.850 3.749 DSX1 Area Luminaire - EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. 22 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 3 of 8COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Area Size 1 homepage. Photometric Diagrams Isofootcandle plots for the DSX1 LED 60C 1000 40K. Distances are in units of mounting height (25’). LEGEND 0.1 fc 0.5 fc 1.0 fc Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T1S Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T2M Test No. LTL23222 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T2S Test No. LTL23271 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T3M Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T3S Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T4M Test No. LTL23222 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 TFTM Test No. LTL23271 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5VS Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5S Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5M Test No. LTL23222 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5W Test No. LTL23271 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 BLC Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 LCCO Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 RCCO 23 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 4 of 8COMMERCIAL OUTDOOR Performance Data Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers Ambient Lumen Multiplier 0°C 32°F 1.04 5°C 41°F 1.04 10°C 50°F 1.03 15°C 50°F 1.02 20°C 68°F 1.01 25°C 77°F 1.00 30°C 86°F 0.99 35°C 95°F 0.98 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Motion Sensor Default Settings Option Dimmed State High Level (when triggered) Phototcell Operation Dwell Time Ramp-up Time Ramp-down Time PIR or PIRH 3V (37%) Output 10V (100%) Output Enabled @ 5FC 5 min 3 sec 5 min *PIR1FC3V or PIRH1FC3V 3V (37%) Output 10V (100%) Output Enabled @ 1FC 5 min 3 sec 5 min *for use when motion sensor is used as dusk to dawn control. Current (A) Performance Package LED Count Drive Current Wattage 120 208 240 277 347 480 Forward Optics (Non-Rotated) P1 30 530 54 0.45 0.26 0.23 0.19 0.10 0.12 P2 30 700 70 0.59 0.34 0.30 0.25 0.20 0.16 P3 30 1050 102 0.86 0.50 0.44 0.38 0.30 0.22 P4 30 1250 125 1.06 0.60 0.52 0.46 0.37 0.27 P5 30 1400 138 1.16 0.67 0.58 0.51 0.40 0.29 P6 40 1250 163 1.36 0.78 0.68 0.59 0.47 0.34 P7 40 1400 183 1.53 0.88 0.76 0.66 0.53 0.38 P8 60 1050 207 1.74 0.98 0.87 0.76 0.64 0.49 P9 60 1250 241 2.01 1.16 1.01 0.89 0.70 0.51 Rotated Optics (Requires L90 or R90) P10 60 530 106 0.90 0.52 0.47 0.43 0.33 0.27 P11 60 700 137 1.15 0.67 0.60 0.53 0.42 0.32 P12 60 1050 207 1.74 0.99 0.87 0.76 0.60 0.46 P13 60 1250 231 1.93 1.12 0.97 0.86 0.67 0.49 Electrical Load Controls Options Nomenclature Description Functionality Primary control device Notes FAO Field adjustable output device installed inside the luminaire; wired to the driver dimming leads. Allows the luminaire to be manually dimmed, effectively trimming the light output.FAO device Cannot be used with other controls options that need the 0-10V leads DS Drivers wired independently for 50/50 luminaire operation The luminaire is wired to two separate circuits, allowing for 50/50 operation.Independently wired drivers Requires two separately switched circuits. Consider nLight AIR as a more cost effective alternative. PER5 or PER7 Twist-lock photocell recepticle Compatible with standard twist-lock photocells for dusk to dawn operation, or advanced control nodes that provide 0-10V dimming signals. Twist-lock photocells such as DLL Elite or advanced control nodes such as ROAM. Pins 4 & 5 to dimming leads on driver, Pins 6 & 7 are capped inside luminaire PIR or PIRH Motion sensors with integral photocell. PIR for 8-15' mounting; PIRH for 15-30' mounting Luminaires dim when no occupancy is detected.Acuity Controls SBGR Also available with PIRH1FC3V when the sensor photocell is used for dusk-to-dawn operation. NLTAIR2 PIRHN nLight AIR enabled luminaire for motion sensing, photocell and wireless communication. Motion and ambient light sensing with group response. Scheduled dimming with motion sensor over-ride when wirelessly connected to the nLight Eclypse.nLight Air rSDGR nLight AIR sensors can be programmed and commissioned from the ground using the ClAIRity Pro app. Operating Hours Lumen Maintenance Factor 0 1.00 25,000 0.96 50,000 0.92 100,000 0.85 24 Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts Contact factory for performance data on any configurations not shown here. Lumen Output Forward Optics LED Count Drive Current Power Package System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 30 530 P1 54W T1S 6,457 2 0 2 120 6,956 2 0 2 129 7,044 2 0 2 130 T2S 6,450 2 0 2 119 6,949 2 0 2 129 7,037 2 0 2 130 T2M 6,483 1 0 1 120 6,984 2 0 2 129 7,073 2 0 2 131 T3S 6,279 2 0 2 116 6,764 2 0 2 125 6,850 2 0 2 127 T3M 6,468 1 0 2 120 6,967 1 0 2 129 7,056 1 0 2 131 T4M 6,327 1 0 2 117 6,816 1 0 2 126 6,902 1 0 2 128 TFTM 6,464 1 0 2 120 6,963 1 0 2 129 7,051 1 0 2 131 T5VS 6,722 2 0 0 124 7,242 3 0 0 134 7,334 3 0 0 136 T5S 6,728 2 0 1 125 7,248 2 0 1 134 7,340 2 0 1 136 T5M 6,711 3 0 1 124 7,229 3 0 1 134 7,321 3 0 2 136 T5W 6,667 3 0 2 123 7,182 3 0 2 133 7,273 3 0 2 135 BLC 5,299 1 0 1 98 5,709 1 0 2 106 5,781 1 0 2 107 LCCO 3,943 1 0 2 73 4,248 1 0 2 79 4,302 1 0 2 80 RCCO 3,943 1 0 2 73 4,248 1 0 2 79 4,302 1 0 2 80 30 700 P2 70W T1S 8,249 2 0 2 118 8,886 2 0 2 127 8,999 2 0 2 129 T2S 8,240 2 0 2 118 8,877 2 0 2 127 8,989 2 0 2 128 T2M 8,283 2 0 2 118 8,923 2 0 2 127 9,036 2 0 2 129 T3S 8,021 2 0 2 115 8,641 2 0 2 123 8,751 2 0 2 125 T3M 8,263 2 0 2 118 8,901 2 0 2 127 9,014 2 0 2 129 T4M 8,083 2 0 2 115 8,708 2 0 2 124 8,818 2 0 2 126 TFTM 8,257 2 0 2 118 8,896 2 0 2 127 9,008 2 0 2 129 T5VS 8,588 3 0 0 123 9,252 3 0 0 132 9,369 3 0 0 134 T5S 8,595 3 0 1 123 9,259 3 0 1 132 9,376 3 0 1 134 T5M 8,573 3 0 2 122 9,236 3 0 2 132 9,353 3 0 2 134 T5W 8,517 3 0 2 122 9,175 4 0 2 131 9,291 4 0 2 133 BLC 6,770 1 0 2 97 7,293 1 0 2 104 7,386 1 0 2 106 LCCO 5,038 1 0 2 72 5,427 1 0 2 78 5,496 1 0 2 79 RCCO 5,038 1 0 2 72 5,427 1 0 2 78 5,496 1 0 2 79 30 1050 P3 102W T1S 11,661 2 0 2 114 12,562 3 0 3 123 12,721 3 0 3 125 T2S 11,648 2 0 2 114 12,548 3 0 3 123 12,707 3 0 3 125 T2M 11,708 2 0 2 115 12,613 2 0 2 124 12,773 2 0 2 125 T3S 11,339 2 0 2 111 12,215 3 0 3 120 12,370 3 0 3 121 T3M 11,680 2 0 2 115 12,582 2 0 2 123 12,742 2 0 2 125 T4M 11,426 2 0 3 112 12,309 2 0 3 121 12,465 2 0 3 122 TFTM 11,673 2 0 2 114 12,575 2 0 3 123 12,734 2 0 3 125 T5VS 12,140 3 0 1 119 13,078 3 0 1 128 13,244 3 0 1 130 T5S 12,150 3 0 1 119 13,089 3 0 1 128 13,254 3 0 1 130 T5M 12,119 4 0 2 119 13,056 4 0 2 128 13,221 4 0 2 130 T5W 12,040 4 0 3 118 12,970 4 0 3 127 13,134 4 0 3 129 BLC 9,570 1 0 2 94 10,310 1 0 2 101 10,440 1 0 2 102 LCCO 7,121 1 0 3 70 7,671 1 0 3 75 7,768 1 0 3 76 RCCO 7,121 1 0 3 70 7,671 1 0 3 75 7,768 1 0 3 76 30 1250 P4 125W T1S 13,435 3 0 3 107 14,473 3 0 3 116 14,657 3 0 3 117 T2S 13,421 3 0 3 107 14,458 3 0 3 116 14,641 3 0 3 117 T2M 13,490 2 0 2 108 14,532 3 0 3 116 14,716 3 0 3 118 T3S 13,064 3 0 3 105 14,074 3 0 3 113 14,252 3 0 3 114 T3M 13,457 2 0 2 108 14,497 2 0 2 116 14,681 2 0 2 117 T4M 13,165 2 0 3 105 14,182 2 0 3 113 14,362 2 0 3 115 TFTM 13,449 2 0 3 108 14,488 2 0 3 116 14,672 2 0 3 117 T5VS 13,987 4 0 1 112 15,068 4 0 1 121 15,259 4 0 1 122 T5S 13,999 3 0 1 112 15,080 3 0 1 121 15,271 3 0 1 122 T5M 13,963 4 0 2 112 15,042 4 0 2 120 15,233 4 0 2 122 T5W 13,872 4 0 3 111 14,944 4 0 3 120 15,133 4 0 3 121 BLC 11,027 1 0 2 88 11,879 1 0 2 95 12,029 1 0 2 96 LCCO 8,205 1 0 3 66 8,839 1 0 3 71 8,951 1 0 3 72 RCCO 8,205 1 0 3 66 8,839 1 0 3 71 8,951 1 0 3 72 30 1400 P5 138W T1S 14,679 3 0 3 106 15,814 3 0 3 115 16,014 3 0 3 116 T2S 14,664 3 0 3 106 15,797 3 0 3 114 15,997 3 0 3 116 T2M 14,739 3 0 3 107 15,878 3 0 3 115 16,079 3 0 3 117 T3S 14,274 3 0 3 103 15,377 3 0 3 111 15,572 3 0 3 113 T3M 14,704 2 0 3 107 15,840 3 0 3 115 16,040 3 0 3 116 T4M 14,384 2 0 3 104 15,496 3 0 3 112 15,692 3 0 3 114 TFTM 14,695 2 0 3 106 15,830 3 0 3 115 16,030 3 0 3 116 T5VS 15,283 4 0 1 111 16,464 4 0 1 119 16,672 4 0 1 121 T5S 15,295 3 0 1 111 16,477 4 0 1 119 16,686 4 0 1 121 T5M 15,257 4 0 2 111 16,435 4 0 2 119 16,644 4 0 2 121 T5W 15,157 4 0 3 110 16,328 4 0 3 118 16,534 4 0 3 120 BLC 12,048 1 0 2 87 12,979 1 0 2 94 13,143 1 0 2 95 LCCO 8,965 1 0 3 65 9,657 1 0 3 70 9,780 1 0 3 71 RCCO 8,965 1 0 3 65 9,657 1 0 3 70 9,780 1 0 3 71 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 5 of 8COMMERCIAL OUTDOOR 25 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Forward Optics LED Count Drive Current Power Package System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 40 1250 P6 163W T1S 17,654 3 0 3 108 19,018 3 0 3 117 19,259 3 0 3 118 T2S 17,635 3 0 3 108 18,998 3 0 3 117 19,238 3 0 3 118 T2M 17,726 3 0 3 109 19,096 3 0 3 117 19,337 3 0 3 119 T3S 17,167 3 0 3 105 18,493 3 0 3 113 18,727 3 0 3 115 T3M 17,683 3 0 3 108 19,049 3 0 3 117 19,290 3 0 3 118 T4M 17,299 3 0 3 106 18,635 3 0 4 114 18,871 3 0 4 116 TFTM 17,672 3 0 3 108 19,038 3 0 4 117 19,279 3 0 4 118 T5VS 18,379 4 0 1 113 19,800 4 0 1 121 20,050 4 0 1 123 T5S 18,394 4 0 2 113 19,816 4 0 2 122 20,066 4 0 2 123 T5M 18,348 4 0 2 113 19,766 4 0 2 121 20,016 4 0 2 123 T5W 18,228 5 0 3 112 19,636 5 0 3 120 19,885 5 0 3 122 BLC 14,489 2 0 2 89 15,609 2 0 3 96 15,806 2 0 3 97 LCCO 10,781 1 0 3 66 11,614 1 0 3 71 11,761 2 0 3 72 RCCO 10,781 1 0 3 66 11,614 1 0 3 71 11,761 2 0 3 72 40 1400 P7 183W T1S 19,227 3 0 3 105 20,712 3 0 3 113 20,975 3 0 3 115 T2S 19,206 3 0 3 105 20,690 3 0 3 113 20,952 3 0 3 114 T2M 19,305 3 0 3 105 20,797 3 0 3 114 21,060 3 0 3 115 T3S 18,696 3 0 3 102 20,141 3 0 3 110 20,396 3 0 4 111 T3M 19,258 3 0 3 105 20,746 3 0 3 113 21,009 3 0 3 115 T4M 18,840 3 0 4 103 20,296 3 0 4 111 20,553 3 0 4 112 TFTM 19,246 3 0 4 105 20,734 3 0 4 113 20,996 3 0 4 115 T5VS 20,017 4 0 1 109 21,564 4 0 1 118 21,837 4 0 1 119 T5S 20,033 4 0 2 109 21,581 4 0 2 118 21,854 4 0 2 119 T5M 19,983 4 0 2 109 21,527 5 0 3 118 21,799 5 0 3 119 T5W 19,852 5 0 3 108 21,386 5 0 3 117 21,656 5 0 3 118 BLC 15,780 2 0 3 86 16,999 2 0 3 93 17,214 2 0 3 94 LCCO 11,742 2 0 3 64 12,649 2 0 3 69 12,809 2 0 3 70 RCCO 11,742 2 0 3 64 12,649 2 0 3 69 12,809 2 0 3 70 60 1050 P8 207W T1S 22,490 3 0 3 109 24,228 3 0 3 117 24,535 3 0 3 119 T2S 22,466 3 0 4 109 24,202 3 0 4 117 24,509 3 0 4 118 T2M 22,582 3 0 3 109 24,327 3 0 3 118 24,635 3 0 3 119 T3S 21,870 3 0 4 106 23,560 3 0 4 114 23,858 3 0 4 115 T3M 22,527 3 0 4 109 24,268 3 0 4 117 24,575 3 0 4 119 T4M 22,038 3 0 4 106 23,741 3 0 4 115 24,041 3 0 4 116 TFTM 22,513 3 0 4 109 24,253 3 0 4 117 24,560 3 0 4 119 T5VS 23,415 5 0 1 113 25,224 5 0 1 122 25,543 5 0 1 123 T5S 23,434 4 0 2 113 25,244 4 0 2 122 25,564 4 0 2 123 T5M 23,374 5 0 3 113 25,181 5 0 3 122 25,499 5 0 3 123 T5W 23,221 5 0 4 112 25,016 5 0 4 121 25,332 5 0 4 122 BLC 18,458 2 0 3 89 19,885 2 0 3 96 20,136 2 0 3 97 LCCO 13,735 2 0 3 66 14,796 2 0 4 71 14,983 2 0 4 72 RCCO 13,735 2 0 3 66 14,796 2 0 4 71 14,983 2 0 4 72 60 1250 P9 241W T1S 25,575 3 0 3 106 27,551 3 0 3 114 27,900 3 0 3 116 T2S 25,548 3 0 4 106 27,522 3 0 4 114 27,871 3 0 4 116 T2M 25,680 3 0 3 107 27,664 3 0 3 115 28,014 3 0 3 116 T3S 24,870 3 0 4 103 26,791 3 0 4 111 27,130 3 0 4 113 T3M 25,617 3 0 4 106 27,597 3 0 4 115 27,946 3 0 4 116 T4M 25,061 3 0 4 104 26,997 3 0 4 112 27,339 3 0 4 113 TFTM 25,602 3 0 4 106 27,580 3 0 4 114 27,929 3 0 4 116 T5VS 26,626 5 0 1 110 28,684 5 0 1 119 29,047 5 0 1 121 T5S 26,648 4 0 2 111 28,707 5 0 2 119 29,070 5 0 2 121 T5M 26,581 5 0 3 110 28,635 5 0 3 119 28,997 5 0 3 120 T5W 26,406 5 0 4 110 28,447 5 0 4 118 28,807 5 0 4 120 BLC 20,990 2 0 3 87 22,612 2 0 3 94 22,898 2 0 3 95 LCCO 15,619 2 0 4 65 16,825 2 0 4 70 17,038 2 0 4 71 RCCO 15,619 2 0 4 65 16,825 2 0 4 70 17,038 2 0 4 71 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 6 of 8COMMERCIAL OUTDOOR Performance Data Lumen Output 26 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 7 of 8COMMERCIAL OUTDOOR Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Data Lumen Output Rotated Optics LED Count Drive Current Power Package System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 60 530 P10 106W T1S 13,042 3 0 3 123 14,050 3 0 3 133 14,228 3 0 3 134 T2S 12,967 4 0 4 122 13,969 4 0 4 132 14,146 4 0 4 133 T2M 13,201 3 0 3 125 14,221 3 0 3 134 14,401 3 0 3 136 T3S 12,766 4 0 4 120 13,752 4 0 4 130 13,926 4 0 4 131 T3M 13,193 4 0 4 124 14,213 4 0 4 134 14,393 4 0 4 136 T4M 12,944 4 0 4 122 13,945 4 0 4 132 14,121 4 0 4 133 TFTM 13,279 4 0 4 125 14,305 4 0 4 135 14,486 4 0 4 137 T5VS 13,372 3 0 1 126 14,405 4 0 1 136 14,588 4 0 1 138 T5S 13,260 3 0 1 125 14,284 3 0 1 135 14,465 3 0 1 136 T5M 13,256 4 0 2 125 14,281 4 0 2 135 14,462 4 0 2 136 T5W 13,137 4 0 3 124 14,153 4 0 3 134 14,332 4 0 3 135 BLC 10,906 3 0 3 103 11,749 3 0 3 111 11,898 3 0 3 112 LCCO 7,789 1 0 3 73 8,391 1 0 3 79 8,497 1 0 3 80 RCCO 7,779 4 0 4 73 8,380 4 0 4 79 8,486 4 0 4 80 60 700 P11 137W T1S 16,556 3 0 3 121 17,835 3 0 3 130 18,061 4 0 4 132 T2S 16,461 4 0 4 120 17,733 4 0 4 129 17,957 4 0 4 131 T2M 16,758 4 0 4 122 18,053 4 0 4 132 18,281 4 0 4 133 T3S 16,205 4 0 4 118 17,457 4 0 4 127 17,678 4 0 4 129 T3M 16,748 4 0 4 122 18,042 4 0 4 132 18,271 4 0 4 133 T4M 16,432 4 0 4 120 17,702 4 0 4 129 17,926 4 0 4 131 TFTM 16,857 4 0 4 123 18,159 4 0 4 133 18,389 4 0 4 134 T5VS 16,975 4 0 1 124 18,287 4 0 1 133 18,518 4 0 1 135 T5S 16,832 4 0 1 123 18,133 4 0 2 132 18,362 4 0 2 134 T5M 16,828 4 0 2 123 18,128 4 0 2 132 18,358 4 0 2 134 T5W 16,677 4 0 3 122 17,966 5 0 3 131 18,193 5 0 3 133 BLC 13,845 3 0 3 101 14,915 3 0 3 109 15,103 3 0 3 110 LCCO 9,888 1 0 3 72 10,652 2 0 3 78 10,787 2 0 3 79 RCCO 9,875 4 0 4 72 10,638 4 0 4 78 10,773 4 0 4 79 60 1050 P12 207W T1S 22,996 4 0 4 111 24,773 4 0 4 120 25,087 4 0 4 121 T2S 22,864 4 0 4 110 24,631 5 0 5 119 24,943 5 0 5 120 T2M 23,277 4 0 4 112 25,075 4 0 4 121 25,393 4 0 4 123 T3S 22,509 4 0 4 109 24,248 5 0 5 117 24,555 5 0 5 119 T3M 23,263 4 0 4 112 25,061 4 0 4 121 25,378 4 0 4 123 T4M 22,824 5 0 5 110 24,588 5 0 5 119 24,899 5 0 5 120 TFTM 23,414 5 0 5 113 25,223 5 0 5 122 25,543 5 0 5 123 T5VS 23,579 5 0 1 114 25,401 5 0 1 123 25,722 5 0 1 124 T5S 23,380 4 0 2 113 25,187 4 0 2 122 25,506 4 0 2 123 T5M 23,374 5 0 3 113 25,181 5 0 3 122 25,499 5 0 3 123 T5W 23,165 5 0 4 112 24,955 5 0 4 121 25,271 5 0 4 122 BLC 19,231 4 0 4 93 20,717 4 0 4 100 20,979 4 0 4 101 LCCO 13,734 2 0 3 66 14,796 2 0 4 71 14,983 2 0 4 72 RCCO 13,716 4 0 4 66 14,776 4 0 4 71 14,963 4 0 4 72 60 1250 P13 231W T1S 25,400 4 0 4 110 27,363 4 0 4 118 27,709 4 0 4 120 T2S 25,254 5 0 5 109 27,205 5 0 5 118 27,550 5 0 5 119 T2M 25,710 4 0 4 111 27,696 4 0 4 120 28,047 4 0 4 121 T3S 24,862 5 0 5 108 26,783 5 0 5 116 27,122 5 0 5 117 T3M 25,695 5 0 5 111 27,680 5 0 5 120 28,031 5 0 5 121 T4M 25,210 5 0 5 109 27,158 5 0 5 118 27,502 5 0 5 119 TFTM 25,861 5 0 5 112 27,860 5 0 5 121 28,212 5 0 5 122 T5VS 26,043 5 0 1 113 28,056 5 0 1 121 28,411 5 0 1 123 T5S 25,824 4 0 2 112 27,819 5 0 2 120 28,172 5 0 2 122 T5M 25,818 5 0 3 112 27,813 5 0 3 120 28,165 5 0 3 122 T5W 25,586 5 0 4 111 27,563 5 0 4 119 27,912 5 0 4 121 BLC 21,241 4 0 4 92 22,882 4 0 4 99 23,172 4 0 4 100 LCCO 15,170 2 0 4 66 16,342 2 0 4 71 16,549 2 0 4 72 RCCO 15,150 5 0 5 66 16,321 5 0 5 71 16,527 5 0 5 72 27 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 8 of 8COMMERCIAL OUTDOOR FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series Size 1 reflects the embedded high performance LED technology. It is ideal for many commercial and municipal applications, such as parking lots, plazas, campuses, and streetscapes. CONSTRUCTION Single-piece die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. Modular design allows for ease of maintenance and future light engine upgrades. The LED drivers are mounted in direct contact with the casting to promote low operating temperature and long life. Housing is completely sealed against moisture and environmental contaminants (IP65). Low EPA (1.01 ft2) for optimized pole wind loading. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Available in both textured and non-textured finishes. OPTICS Precision-molded proprietary acrylic lenses are engineered for superior area lighting distribution, uniformity, and pole spacing. Light engines are available in standard 3000 K, 4000 K and 5000 K (70 CRI) configurations. The D-Series Size 1 has zero uplight and qualifies as a Nighttime FriendlyTM product, meaning it is consistent with the LEED® and Green GlobesTM criteria for eliminating wasteful uplight. ELECTRICAL Light engine configurations consist of high-efficacy LEDs mounted to metal- core circuit boards to maximize heat dissipation and promote long life (up to L85/100,000 hours at 25°C). Class 1 electronic drivers are designed to have a power factor >90%, THD <20%, and an expected life of 100,000 hours with <1% failure rate. Easily serviceable 10kV surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). STANDARD CONTROLS The DSX1 LED area luminaire has a number of control options. DSX Size 1, comes standard with 0-10V dimming drivers. Dusk to dawn controls can be utilized via optional NEMA twist-lock photocell receptacles. Integrated motion sensors with on-board photocells feature field-adjustable programing and are suitable for mounting heights up to 30 feet. nLIGHT AIR CONTROLS The DSX1 LED area luminaire is also available with nLight® AIR for the ultimate in wireless control. This powerful controls platform provides out-of-the-box basic motion sensing and photocontrol functionality and is suitable for mounting heights up to 40 feet. Once commissioned using a smartphone and the easy-to- use CLAIRITY app, nLight AIR equipped luminaries can be grouped, resulting in motion sensor and photocell group response without the need for additional equipment. Scheduled dimming with motion sensor over-ride can be achieved when used with the nLight Eclypse. Additional information about nLight Air can be found here. INSTALLATION Included mounting block and integral arm facilitate quick and easy installation. Stainless steel bolts fasten the mounting block securely to poles and walls, enabling the D-Series Size 1 to withstand up to a 3.0 G vibration load rating per ANSI C136.31. The D-Series Size 1 utilizes the AERISTM series pole drilling pattern (template #8). NEMA photocontrol receptacle are also available. LISTINGS UL Listed for wet locations. Light engines are IP66 rated; luminaire is IP65 rated. Rated for -40°C minimum ambient. U.S. Patent No. D672,492 S. International patent pending. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/ QPL to confirm which versions are qualified. International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page utilizing 3000K color temperature only. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/support/customer-support/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. 28 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 1 of 8COMMERCIAL OUTDOOR D-Series Size 1 LED Area Luminaire Catalog Number Notes Type Introduction The modern styling of the D-Series is striking yet unobtrusive - making a bold, progressive statement even as it blends seamlessly with its environment. The D-Series distills the benefits of the latest in LED technology into a high performance, high efficacy, long-life luminaire. The outstanding photometric performance results in sites with excellent uniformity, greater pole spacing and lower power density. It is ideal for replacing up to 750W metal halide in pedestrian and area lighting applications with typical energy savings of 65% and expected service life of over 100,000 hours. Hit the Tab key or mouse over the page to see all interactive elements. L H L H1 WW HH2 Ordering Information EXAMPLE: DSX1 LED P7 40K T3M MVOLT SPA NLTAIR2 PIRHN DDBXD DSX1 LED Series LEDs Color temperature Distribution Voltage Mounting DSX1 LED Forward optics P1 P4 1 P7 1 P2 P5 1 P8 P3 P6 1 P9 1 Rotated optics P10 2 P12 2 P11 2 P13 1,2 30K 3000 K 40K 4000 K 50K 5000 K T1S Type I short (Automotive) T2S Type II short T2M Type II medium T3S Type III short T3M Type III medium T4M Type IV medium TFTM Forward throw medium T5VS Type V very short 3 T5S Type V short 3 T5M Type V medium 3 T5W Type V wide 3 BLC Backlight control 4 LCCO Left corner cutoff 4 RCCO Right corner cutoff 4 MVOLT 5 120 6 208 6 240 6 277 6 347 6 480 6 Shipped included SPA Square pole mounting RPA Round pole mounting 7 WBA Wall bracket 3 SPUMBA Square pole universal mounting adaptor 8 RPUMBA Round pole universal mounting adaptor 8 Shipped separately KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish) 9 Specifications EPA:1.01 ft2 (0.09 m2) Length:33” (83.8 cm) Width:13” (33.0 cm) Height H1:7-1/2” (19.0 cm) Height H2:3-1/2” Weight (max):27 lbs (12.2 kg) Control options Other options Finish (required) Shipped installed NLTAIR2 nLight AIR generation 2 enabled 10 PIRHN Network, high/low motion/ambient sensor 11 PER NEMA twist-lock receptacle only (controls ordered separate) 12 PER5 Five-pin receptacle only (controls ordered separate) 12,13 PER7 Seven-pin receptacle only (controls ordered separate) 12,13 DMG 0-10v dimming wires pulled outside fixture (for use with an external control, ordered separately) 14 DS Dual switching 15,16,17 PIR High/low, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 5fc 17,18 PIRH High/low, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 5fc 17,18 PIR1FC3V High/low, motion/ambient sensor, 8-15’ mounting height, ambient sensor enabled at 1fc 17,18 PIRH1FC3V Bi-level, motion/ambient sensor, 15-30’ mounting height, ambient sensor enabled at 1fc 17,18 FAO Field adjustable output 17,19 Shipped installed HS House-side shield 20 SF Single fuse (120, 277, 347V) 6 DF Double fuse (208, 240, 480V) 6 L90 Left rotated optics 2 R90 Right rotated optics 2 HA 50°C ambient operations 1 Shipped separately BS Bird spikes 21 EGS External glare shield DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white 29 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 2 of 8COMMERCIAL OUTDOOR Tenon O.D. Mounting Single Unit 2 @ 180 2 @ 90 3 @ 90 3 @120 4 @ 90 2-3/8"RPA AS3-5 190 AS3-5 280 AS3-5 290 AS3-5 390 AS3-5 320 AS3-5 490 2-7/8"RPA AST25-190 AST25-280 AST25-290 AST25-390 AST25-320 AST25-490 4"RPA AST35-190 AST35-280 AST35-290 AST35-390 AST35-320 AST35-490 Tenon Mounting Slipfitter Drilling Top of Pole 0.563” 2.650” 1.325”0.400”(2 PLCS) Template #8 Ordering Information NOTES 1 HA not available with P4, P5, P6, P7, P9 and P13. 2 P10, P11, P12 or P13 and rotated optics (L90, R90) only available together. 3 Any Type 5 distribution with photocell, is not available with WBA. 4 Not available with HS. 5 MVOLT driver operates on any line voltage from 120-277V (50/60 Hz). 6 Single fuse (SF) requires 120V, 277V or 347V. Double fuse (DF) requires 208V, 240V or 480V. 7 Suitable for mounting to round poles between 3.5” and 12” diameter. 8 Universal mounting brackets intended for retrofit on existing, pre-drilled poles only. 1.5 G vibration load rating per ANCI C136.31. Only usable when pole’s drill pattern is NOT Lithonia template #8 9 Must order fixture with SPA option. Must be ordered as a separate accessory; see Accessories information. For use with 2-3/8” diameter mast arm (not included). 10 Must be ordered with PIRHN. Sensor cover available only in dark bronze, black, white and natural aluminum colors. 11 Must be ordered with NLTAIR2. For more information on nLight Air 2 visit this link. 12 Photocell ordered and shipped as a separate line item from Acuity Brands Controls. See accessories. Shorting cap included. 13 If ROAM® node required, it must be ordered and shipped as a separate line item from Acuity Brands Controls. Node with integral dimming. 14 DMG not available with PIRHN, PER5, PER7, PIR, PIRH, PIR1FC3V or PIRH1FC3V, FAO. 15 Provides 50/50fixture operation via (2) independent drivers. Not available with PER, PER5, PER7, PIR or PIRH. Not available P1, P2, P3, P4 or P5. 16 Requires (2) separately switched circuits with isolated neutrol. 17 Reference Controls Option Default settings table on page 4. 18 Reference Motion Sensor table on page 4 to see functionality. 19 Not available with other dimming controls options 20 Not available with BLC, LCCO and RCCO distribution. Also available as a separate accessory; see Accessories information. 21 Must be ordered with fixture for factory pre-drilling. 22 Requires luminaire to be specified with PER, PER5 or PER7 option. See Control Option Table on page 4. 23 For retrofit use only. Only usable when pole’s drill pattern is NOT Lithonia template #8 Accessories Ordered and shipped separately. DLL127F 1.5 JU Photocell - SSL twist-lock (120-277V) 22 DLL347F 1.5 CUL JU Photocell - SSL twist-lock (347V) 22 DLL480F 1.5 CUL JU Photocell - SSL twist-lock (480V) 22 DSHORT SBK U Shorting cap 22 DSX1HS 30C U House-side shield for P1, P2, P3, P4 and P5 20 DSX1HS 40C U House-side shield for P6 and P7 20 DSX1HS 60C U House-side shield for P8, P9, P10, P11 and P12 20 PUMBA DDBXD U*Square and round pole universal mounting bracket (specify finish) 23 KMA8 DDBXD U Mast arm mounting bracket adaptor (specify finish) 9 DSX1EGS (FINISH) U External glare shield For more control options, visit DTL and ROAM online. Options .50 73˚ 12.05 12.476 .50 73˚ 12.05 12.48 HANDHOLE ORIENTATION A Handhole B C D EGS - External Glare Shield Drilling Template Minimum Acceptable Outside Pole Dimension SPA #8 2-7/8” 2-7/8” 3.5”3.5”3”3.5” RPA #8 2-7/8” 2-7/8” 3.5”3.5”3”3.5” SPUMBA #5 2-7/8” 3”4”4”3.5”4” RPUMBA #5 2-7/8” 3.5”5” 5” 3.5”5” Mounting Option Drilling Template Single 2 @ 180 2 @ 90 3 @ 90 3 @ 120 4 @ 90 Head Location Side B Side B & D Side B & C Side B, C & D Round Pole Only Side A, B, C & D Drill Nomenclature #8 DM19AS DM28AS DM29AS DM39AS DM32AS DM49AS 1.75” for aluminum poles 2.75” for other pole types Fixture Quantity & Mounting Configuration Single DM19 2 @ 180 DM28 2 @ 90 DM29 3 @ 90 DM39 3 @ 120 DM32 4 @ 90 DM49 Mounting Type DSX1 LED 1.013 2.025 1.945 3.038 2.850 3.749 DSX1 Area Luminaire - EPA *Includes luminaire and integral mounting arm. Other tenons, arms, brackets or other accessories are not included in this EPA data. 30 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 3 of 8COMMERCIAL OUTDOOR To see complete photometric reports or download .ies files for this product, visit Lithonia Lighting’s D-Series Area Size 1 homepage. Photometric Diagrams Isofootcandle plots for the DSX1 LED 60C 1000 40K. Distances are in units of mounting height (25’). LEGEND 0.1 fc 0.5 fc 1.0 fc Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T1S Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T2M Test No. LTL23222 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T2S Test No. LTL23271 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T3M Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T3S Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T4M Test No. LTL23222 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 TFTM Test No. LTL23271 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5VS Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5S Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5M Test No. LTL23222 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 T5W Test No. LTL23271 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 BLC Test No. LTL23211 tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 LCCO Test No. LTL23164B tested in accordance with IESNA LM-79-08.4 3 2 1 0 -4 -3 -2 -1 4 3 2 1 0 4321 RCCO 31 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 4 of 8COMMERCIAL OUTDOOR Performance Data Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers Ambient Lumen Multiplier 0°C 32°F 1.04 5°C 41°F 1.04 10°C 50°F 1.03 15°C 50°F 1.02 20°C 68°F 1.01 25°C 77°F 1.00 30°C 86°F 0.99 35°C 95°F 0.98 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Motion Sensor Default Settings Option Dimmed State High Level (when triggered) Phototcell Operation Dwell Time Ramp-up Time Ramp-down Time PIR or PIRH 3V (37%) Output 10V (100%) Output Enabled @ 5FC 5 min 3 sec 5 min *PIR1FC3V or PIRH1FC3V 3V (37%) Output 10V (100%) Output Enabled @ 1FC 5 min 3 sec 5 min *for use when motion sensor is used as dusk to dawn control. Current (A) Performance Package LED Count Drive Current Wattage 120 208 240 277 347 480 Forward Optics (Non-Rotated) P1 30 530 54 0.45 0.26 0.23 0.19 0.10 0.12 P2 30 700 70 0.59 0.34 0.30 0.25 0.20 0.16 P3 30 1050 102 0.86 0.50 0.44 0.38 0.30 0.22 P4 30 1250 125 1.06 0.60 0.52 0.46 0.37 0.27 P5 30 1400 138 1.16 0.67 0.58 0.51 0.40 0.29 P6 40 1250 163 1.36 0.78 0.68 0.59 0.47 0.34 P7 40 1400 183 1.53 0.88 0.76 0.66 0.53 0.38 P8 60 1050 207 1.74 0.98 0.87 0.76 0.64 0.49 P9 60 1250 241 2.01 1.16 1.01 0.89 0.70 0.51 Rotated Optics (Requires L90 or R90) P10 60 530 106 0.90 0.52 0.47 0.43 0.33 0.27 P11 60 700 137 1.15 0.67 0.60 0.53 0.42 0.32 P12 60 1050 207 1.74 0.99 0.87 0.76 0.60 0.46 P13 60 1250 231 1.93 1.12 0.97 0.86 0.67 0.49 Electrical Load Controls Options Nomenclature Description Functionality Primary control device Notes FAO Field adjustable output device installed inside the luminaire; wired to the driver dimming leads. Allows the luminaire to be manually dimmed, effectively trimming the light output.FAO device Cannot be used with other controls options that need the 0-10V leads DS Drivers wired independently for 50/50 luminaire operation The luminaire is wired to two separate circuits, allowing for 50/50 operation.Independently wired drivers Requires two separately switched circuits. Consider nLight AIR as a more cost effective alternative. PER5 or PER7 Twist-lock photocell recepticle Compatible with standard twist-lock photocells for dusk to dawn operation, or advanced control nodes that provide 0-10V dimming signals. Twist-lock photocells such as DLL Elite or advanced control nodes such as ROAM. Pins 4 & 5 to dimming leads on driver, Pins 6 & 7 are capped inside luminaire PIR or PIRH Motion sensors with integral photocell. PIR for 8-15' mounting; PIRH for 15-30' mounting Luminaires dim when no occupancy is detected.Acuity Controls SBGR Also available with PIRH1FC3V when the sensor photocell is used for dusk-to-dawn operation. NLTAIR2 PIRHN nLight AIR enabled luminaire for motion sensing, photocell and wireless communication. Motion and ambient light sensing with group response. Scheduled dimming with motion sensor over-ride when wirelessly connected to the nLight Eclypse.nLight Air rSDGR nLight AIR sensors can be programmed and commissioned from the ground using the ClAIRity Pro app. Operating Hours Lumen Maintenance Factor 0 1.00 25,000 0.96 50,000 0.92 100,000 0.85 32 Performance Data Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts Contact factory for performance data on any configurations not shown here. Lumen Output Forward Optics LED Count Drive Current Power Package System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 30 530 P1 54W T1S 6,457 2 0 2 120 6,956 2 0 2 129 7,044 2 0 2 130 T2S 6,450 2 0 2 119 6,949 2 0 2 129 7,037 2 0 2 130 T2M 6,483 1 0 1 120 6,984 2 0 2 129 7,073 2 0 2 131 T3S 6,279 2 0 2 116 6,764 2 0 2 125 6,850 2 0 2 127 T3M 6,468 1 0 2 120 6,967 1 0 2 129 7,056 1 0 2 131 T4M 6,327 1 0 2 117 6,816 1 0 2 126 6,902 1 0 2 128 TFTM 6,464 1 0 2 120 6,963 1 0 2 129 7,051 1 0 2 131 T5VS 6,722 2 0 0 124 7,242 3 0 0 134 7,334 3 0 0 136 T5S 6,728 2 0 1 125 7,248 2 0 1 134 7,340 2 0 1 136 T5M 6,711 3 0 1 124 7,229 3 0 1 134 7,321 3 0 2 136 T5W 6,667 3 0 2 123 7,182 3 0 2 133 7,273 3 0 2 135 BLC 5,299 1 0 1 98 5,709 1 0 2 106 5,781 1 0 2 107 LCCO 3,943 1 0 2 73 4,248 1 0 2 79 4,302 1 0 2 80 RCCO 3,943 1 0 2 73 4,248 1 0 2 79 4,302 1 0 2 80 30 700 P2 70W T1S 8,249 2 0 2 118 8,886 2 0 2 127 8,999 2 0 2 129 T2S 8,240 2 0 2 118 8,877 2 0 2 127 8,989 2 0 2 128 T2M 8,283 2 0 2 118 8,923 2 0 2 127 9,036 2 0 2 129 T3S 8,021 2 0 2 115 8,641 2 0 2 123 8,751 2 0 2 125 T3M 8,263 2 0 2 118 8,901 2 0 2 127 9,014 2 0 2 129 T4M 8,083 2 0 2 115 8,708 2 0 2 124 8,818 2 0 2 126 TFTM 8,257 2 0 2 118 8,896 2 0 2 127 9,008 2 0 2 129 T5VS 8,588 3 0 0 123 9,252 3 0 0 132 9,369 3 0 0 134 T5S 8,595 3 0 1 123 9,259 3 0 1 132 9,376 3 0 1 134 T5M 8,573 3 0 2 122 9,236 3 0 2 132 9,353 3 0 2 134 T5W 8,517 3 0 2 122 9,175 4 0 2 131 9,291 4 0 2 133 BLC 6,770 1 0 2 97 7,293 1 0 2 104 7,386 1 0 2 106 LCCO 5,038 1 0 2 72 5,427 1 0 2 78 5,496 1 0 2 79 RCCO 5,038 1 0 2 72 5,427 1 0 2 78 5,496 1 0 2 79 30 1050 P3 102W T1S 11,661 2 0 2 114 12,562 3 0 3 123 12,721 3 0 3 125 T2S 11,648 2 0 2 114 12,548 3 0 3 123 12,707 3 0 3 125 T2M 11,708 2 0 2 115 12,613 2 0 2 124 12,773 2 0 2 125 T3S 11,339 2 0 2 111 12,215 3 0 3 120 12,370 3 0 3 121 T3M 11,680 2 0 2 115 12,582 2 0 2 123 12,742 2 0 2 125 T4M 11,426 2 0 3 112 12,309 2 0 3 121 12,465 2 0 3 122 TFTM 11,673 2 0 2 114 12,575 2 0 3 123 12,734 2 0 3 125 T5VS 12,140 3 0 1 119 13,078 3 0 1 128 13,244 3 0 1 130 T5S 12,150 3 0 1 119 13,089 3 0 1 128 13,254 3 0 1 130 T5M 12,119 4 0 2 119 13,056 4 0 2 128 13,221 4 0 2 130 T5W 12,040 4 0 3 118 12,970 4 0 3 127 13,134 4 0 3 129 BLC 9,570 1 0 2 94 10,310 1 0 2 101 10,440 1 0 2 102 LCCO 7,121 1 0 3 70 7,671 1 0 3 75 7,768 1 0 3 76 RCCO 7,121 1 0 3 70 7,671 1 0 3 75 7,768 1 0 3 76 30 1250 P4 125W T1S 13,435 3 0 3 107 14,473 3 0 3 116 14,657 3 0 3 117 T2S 13,421 3 0 3 107 14,458 3 0 3 116 14,641 3 0 3 117 T2M 13,490 2 0 2 108 14,532 3 0 3 116 14,716 3 0 3 118 T3S 13,064 3 0 3 105 14,074 3 0 3 113 14,252 3 0 3 114 T3M 13,457 2 0 2 108 14,497 2 0 2 116 14,681 2 0 2 117 T4M 13,165 2 0 3 105 14,182 2 0 3 113 14,362 2 0 3 115 TFTM 13,449 2 0 3 108 14,488 2 0 3 116 14,672 2 0 3 117 T5VS 13,987 4 0 1 112 15,068 4 0 1 121 15,259 4 0 1 122 T5S 13,999 3 0 1 112 15,080 3 0 1 121 15,271 3 0 1 122 T5M 13,963 4 0 2 112 15,042 4 0 2 120 15,233 4 0 2 122 T5W 13,872 4 0 3 111 14,944 4 0 3 120 15,133 4 0 3 121 BLC 11,027 1 0 2 88 11,879 1 0 2 95 12,029 1 0 2 96 LCCO 8,205 1 0 3 66 8,839 1 0 3 71 8,951 1 0 3 72 RCCO 8,205 1 0 3 66 8,839 1 0 3 71 8,951 1 0 3 72 30 1400 P5 138W T1S 14,679 3 0 3 106 15,814 3 0 3 115 16,014 3 0 3 116 T2S 14,664 3 0 3 106 15,797 3 0 3 114 15,997 3 0 3 116 T2M 14,739 3 0 3 107 15,878 3 0 3 115 16,079 3 0 3 117 T3S 14,274 3 0 3 103 15,377 3 0 3 111 15,572 3 0 3 113 T3M 14,704 2 0 3 107 15,840 3 0 3 115 16,040 3 0 3 116 T4M 14,384 2 0 3 104 15,496 3 0 3 112 15,692 3 0 3 114 TFTM 14,695 2 0 3 106 15,830 3 0 3 115 16,030 3 0 3 116 T5VS 15,283 4 0 1 111 16,464 4 0 1 119 16,672 4 0 1 121 T5S 15,295 3 0 1 111 16,477 4 0 1 119 16,686 4 0 1 121 T5M 15,257 4 0 2 111 16,435 4 0 2 119 16,644 4 0 2 121 T5W 15,157 4 0 3 110 16,328 4 0 3 118 16,534 4 0 3 120 BLC 12,048 1 0 2 87 12,979 1 0 2 94 13,143 1 0 2 95 LCCO 8,965 1 0 3 65 9,657 1 0 3 70 9,780 1 0 3 71 RCCO 8,965 1 0 3 65 9,657 1 0 3 70 9,780 1 0 3 71 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 5 of 8COMMERCIAL OUTDOOR 33 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Forward Optics LED Count Drive Current Power Package System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 40 1250 P6 163W T1S 17,654 3 0 3 108 19,018 3 0 3 117 19,259 3 0 3 118 T2S 17,635 3 0 3 108 18,998 3 0 3 117 19,238 3 0 3 118 T2M 17,726 3 0 3 109 19,096 3 0 3 117 19,337 3 0 3 119 T3S 17,167 3 0 3 105 18,493 3 0 3 113 18,727 3 0 3 115 T3M 17,683 3 0 3 108 19,049 3 0 3 117 19,290 3 0 3 118 T4M 17,299 3 0 3 106 18,635 3 0 4 114 18,871 3 0 4 116 TFTM 17,672 3 0 3 108 19,038 3 0 4 117 19,279 3 0 4 118 T5VS 18,379 4 0 1 113 19,800 4 0 1 121 20,050 4 0 1 123 T5S 18,394 4 0 2 113 19,816 4 0 2 122 20,066 4 0 2 123 T5M 18,348 4 0 2 113 19,766 4 0 2 121 20,016 4 0 2 123 T5W 18,228 5 0 3 112 19,636 5 0 3 120 19,885 5 0 3 122 BLC 14,489 2 0 2 89 15,609 2 0 3 96 15,806 2 0 3 97 LCCO 10,781 1 0 3 66 11,614 1 0 3 71 11,761 2 0 3 72 RCCO 10,781 1 0 3 66 11,614 1 0 3 71 11,761 2 0 3 72 40 1400 P7 183W T1S 19,227 3 0 3 105 20,712 3 0 3 113 20,975 3 0 3 115 T2S 19,206 3 0 3 105 20,690 3 0 3 113 20,952 3 0 3 114 T2M 19,305 3 0 3 105 20,797 3 0 3 114 21,060 3 0 3 115 T3S 18,696 3 0 3 102 20,141 3 0 3 110 20,396 3 0 4 111 T3M 19,258 3 0 3 105 20,746 3 0 3 113 21,009 3 0 3 115 T4M 18,840 3 0 4 103 20,296 3 0 4 111 20,553 3 0 4 112 TFTM 19,246 3 0 4 105 20,734 3 0 4 113 20,996 3 0 4 115 T5VS 20,017 4 0 1 109 21,564 4 0 1 118 21,837 4 0 1 119 T5S 20,033 4 0 2 109 21,581 4 0 2 118 21,854 4 0 2 119 T5M 19,983 4 0 2 109 21,527 5 0 3 118 21,799 5 0 3 119 T5W 19,852 5 0 3 108 21,386 5 0 3 117 21,656 5 0 3 118 BLC 15,780 2 0 3 86 16,999 2 0 3 93 17,214 2 0 3 94 LCCO 11,742 2 0 3 64 12,649 2 0 3 69 12,809 2 0 3 70 RCCO 11,742 2 0 3 64 12,649 2 0 3 69 12,809 2 0 3 70 60 1050 P8 207W T1S 22,490 3 0 3 109 24,228 3 0 3 117 24,535 3 0 3 119 T2S 22,466 3 0 4 109 24,202 3 0 4 117 24,509 3 0 4 118 T2M 22,582 3 0 3 109 24,327 3 0 3 118 24,635 3 0 3 119 T3S 21,870 3 0 4 106 23,560 3 0 4 114 23,858 3 0 4 115 T3M 22,527 3 0 4 109 24,268 3 0 4 117 24,575 3 0 4 119 T4M 22,038 3 0 4 106 23,741 3 0 4 115 24,041 3 0 4 116 TFTM 22,513 3 0 4 109 24,253 3 0 4 117 24,560 3 0 4 119 T5VS 23,415 5 0 1 113 25,224 5 0 1 122 25,543 5 0 1 123 T5S 23,434 4 0 2 113 25,244 4 0 2 122 25,564 4 0 2 123 T5M 23,374 5 0 3 113 25,181 5 0 3 122 25,499 5 0 3 123 T5W 23,221 5 0 4 112 25,016 5 0 4 121 25,332 5 0 4 122 BLC 18,458 2 0 3 89 19,885 2 0 3 96 20,136 2 0 3 97 LCCO 13,735 2 0 3 66 14,796 2 0 4 71 14,983 2 0 4 72 RCCO 13,735 2 0 3 66 14,796 2 0 4 71 14,983 2 0 4 72 60 1250 P9 241W T1S 25,575 3 0 3 106 27,551 3 0 3 114 27,900 3 0 3 116 T2S 25,548 3 0 4 106 27,522 3 0 4 114 27,871 3 0 4 116 T2M 25,680 3 0 3 107 27,664 3 0 3 115 28,014 3 0 3 116 T3S 24,870 3 0 4 103 26,791 3 0 4 111 27,130 3 0 4 113 T3M 25,617 3 0 4 106 27,597 3 0 4 115 27,946 3 0 4 116 T4M 25,061 3 0 4 104 26,997 3 0 4 112 27,339 3 0 4 113 TFTM 25,602 3 0 4 106 27,580 3 0 4 114 27,929 3 0 4 116 T5VS 26,626 5 0 1 110 28,684 5 0 1 119 29,047 5 0 1 121 T5S 26,648 4 0 2 111 28,707 5 0 2 119 29,070 5 0 2 121 T5M 26,581 5 0 3 110 28,635 5 0 3 119 28,997 5 0 3 120 T5W 26,406 5 0 4 110 28,447 5 0 4 118 28,807 5 0 4 120 BLC 20,990 2 0 3 87 22,612 2 0 3 94 22,898 2 0 3 95 LCCO 15,619 2 0 4 65 16,825 2 0 4 70 17,038 2 0 4 71 RCCO 15,619 2 0 4 65 16,825 2 0 4 70 17,038 2 0 4 71 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 6 of 8COMMERCIAL OUTDOOR Performance Data Lumen Output 34 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 7 of 8COMMERCIAL OUTDOOR Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Data Lumen Output Rotated Optics LED Count Drive Current Power Package System Watts Dist. Type 30K (3000 K, 70 CRI) 40K (4000 K, 70 CRI) 50K (5000 K, 70 CRI) Lumens B U G LPW Lumens B U G LPW Lumens B U G LPW 60 530 P10 106W T1S 13,042 3 0 3 123 14,050 3 0 3 133 14,228 3 0 3 134 T2S 12,967 4 0 4 122 13,969 4 0 4 132 14,146 4 0 4 133 T2M 13,201 3 0 3 125 14,221 3 0 3 134 14,401 3 0 3 136 T3S 12,766 4 0 4 120 13,752 4 0 4 130 13,926 4 0 4 131 T3M 13,193 4 0 4 124 14,213 4 0 4 134 14,393 4 0 4 136 T4M 12,944 4 0 4 122 13,945 4 0 4 132 14,121 4 0 4 133 TFTM 13,279 4 0 4 125 14,305 4 0 4 135 14,486 4 0 4 137 T5VS 13,372 3 0 1 126 14,405 4 0 1 136 14,588 4 0 1 138 T5S 13,260 3 0 1 125 14,284 3 0 1 135 14,465 3 0 1 136 T5M 13,256 4 0 2 125 14,281 4 0 2 135 14,462 4 0 2 136 T5W 13,137 4 0 3 124 14,153 4 0 3 134 14,332 4 0 3 135 BLC 10,906 3 0 3 103 11,749 3 0 3 111 11,898 3 0 3 112 LCCO 7,789 1 0 3 73 8,391 1 0 3 79 8,497 1 0 3 80 RCCO 7,779 4 0 4 73 8,380 4 0 4 79 8,486 4 0 4 80 60 700 P11 137W T1S 16,556 3 0 3 121 17,835 3 0 3 130 18,061 4 0 4 132 T2S 16,461 4 0 4 120 17,733 4 0 4 129 17,957 4 0 4 131 T2M 16,758 4 0 4 122 18,053 4 0 4 132 18,281 4 0 4 133 T3S 16,205 4 0 4 118 17,457 4 0 4 127 17,678 4 0 4 129 T3M 16,748 4 0 4 122 18,042 4 0 4 132 18,271 4 0 4 133 T4M 16,432 4 0 4 120 17,702 4 0 4 129 17,926 4 0 4 131 TFTM 16,857 4 0 4 123 18,159 4 0 4 133 18,389 4 0 4 134 T5VS 16,975 4 0 1 124 18,287 4 0 1 133 18,518 4 0 1 135 T5S 16,832 4 0 1 123 18,133 4 0 2 132 18,362 4 0 2 134 T5M 16,828 4 0 2 123 18,128 4 0 2 132 18,358 4 0 2 134 T5W 16,677 4 0 3 122 17,966 5 0 3 131 18,193 5 0 3 133 BLC 13,845 3 0 3 101 14,915 3 0 3 109 15,103 3 0 3 110 LCCO 9,888 1 0 3 72 10,652 2 0 3 78 10,787 2 0 3 79 RCCO 9,875 4 0 4 72 10,638 4 0 4 78 10,773 4 0 4 79 60 1050 P12 207W T1S 22,996 4 0 4 111 24,773 4 0 4 120 25,087 4 0 4 121 T2S 22,864 4 0 4 110 24,631 5 0 5 119 24,943 5 0 5 120 T2M 23,277 4 0 4 112 25,075 4 0 4 121 25,393 4 0 4 123 T3S 22,509 4 0 4 109 24,248 5 0 5 117 24,555 5 0 5 119 T3M 23,263 4 0 4 112 25,061 4 0 4 121 25,378 4 0 4 123 T4M 22,824 5 0 5 110 24,588 5 0 5 119 24,899 5 0 5 120 TFTM 23,414 5 0 5 113 25,223 5 0 5 122 25,543 5 0 5 123 T5VS 23,579 5 0 1 114 25,401 5 0 1 123 25,722 5 0 1 124 T5S 23,380 4 0 2 113 25,187 4 0 2 122 25,506 4 0 2 123 T5M 23,374 5 0 3 113 25,181 5 0 3 122 25,499 5 0 3 123 T5W 23,165 5 0 4 112 24,955 5 0 4 121 25,271 5 0 4 122 BLC 19,231 4 0 4 93 20,717 4 0 4 100 20,979 4 0 4 101 LCCO 13,734 2 0 3 66 14,796 2 0 4 71 14,983 2 0 4 72 RCCO 13,716 4 0 4 66 14,776 4 0 4 71 14,963 4 0 4 72 60 1250 P13 231W T1S 25,400 4 0 4 110 27,363 4 0 4 118 27,709 4 0 4 120 T2S 25,254 5 0 5 109 27,205 5 0 5 118 27,550 5 0 5 119 T2M 25,710 4 0 4 111 27,696 4 0 4 120 28,047 4 0 4 121 T3S 24,862 5 0 5 108 26,783 5 0 5 116 27,122 5 0 5 117 T3M 25,695 5 0 5 111 27,680 5 0 5 120 28,031 5 0 5 121 T4M 25,210 5 0 5 109 27,158 5 0 5 118 27,502 5 0 5 119 TFTM 25,861 5 0 5 112 27,860 5 0 5 121 28,212 5 0 5 122 T5VS 26,043 5 0 1 113 28,056 5 0 1 121 28,411 5 0 1 123 T5S 25,824 4 0 2 112 27,819 5 0 2 120 28,172 5 0 2 122 T5M 25,818 5 0 3 112 27,813 5 0 3 120 28,165 5 0 3 122 T5W 25,586 5 0 4 111 27,563 5 0 4 119 27,912 5 0 4 121 BLC 21,241 4 0 4 92 22,882 4 0 4 99 23,172 4 0 4 100 LCCO 15,170 2 0 4 66 16,342 2 0 4 71 16,549 2 0 4 72 RCCO 15,150 5 0 5 66 16,321 5 0 5 71 16,527 5 0 5 72 35 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2011-2020 Acuity Brands Lighting, Inc. All rights reserved. DSX1-LED Rev. 07/30/20 Page 8 of 8COMMERCIAL OUTDOOR FEATURES & SPECIFICATIONS INTENDED USE The sleek design of the D-Series Size 1 reflects the embedded high performance LED technology. It is ideal for many commercial and municipal applications, such as parking lots, plazas, campuses, and streetscapes. CONSTRUCTION Single-piece die-cast aluminum housing has integral heat sink fins to optimize thermal management through conductive and convective cooling. Modular design allows for ease of maintenance and future light engine upgrades. The LED drivers are mounted in direct contact with the casting to promote low operating temperature and long life. Housing is completely sealed against moisture and environmental contaminants (IP65). Low EPA (1.01 ft2) for optimized pole wind loading. FINISH Exterior parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a minimum 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Available in both textured and non-textured finishes. OPTICS Precision-molded proprietary acrylic lenses are engineered for superior area lighting distribution, uniformity, and pole spacing. Light engines are available in standard 3000 K, 4000 K and 5000 K (70 CRI) configurations. The D-Series Size 1 has zero uplight and qualifies as a Nighttime FriendlyTM product, meaning it is consistent with the LEED® and Green GlobesTM criteria for eliminating wasteful uplight. ELECTRICAL Light engine configurations consist of high-efficacy LEDs mounted to metal- core circuit boards to maximize heat dissipation and promote long life (up to L85/100,000 hours at 25°C). Class 1 electronic drivers are designed to have a power factor >90%, THD <20%, and an expected life of 100,000 hours with <1% failure rate. Easily serviceable 10kV surge protection device meets a minimum Category C Low operation (per ANSI/IEEE C62.41.2). STANDARD CONTROLS The DSX1 LED area luminaire has a number of control options. DSX Size 1, comes standard with 0-10V dimming drivers. Dusk to dawn controls can be utilized via optional NEMA twist-lock photocell receptacles. Integrated motion sensors with on-board photocells feature field-adjustable programing and are suitable for mounting heights up to 30 feet. nLIGHT AIR CONTROLS The DSX1 LED area luminaire is also available with nLight® AIR for the ultimate in wireless control. This powerful controls platform provides out-of-the-box basic motion sensing and photocontrol functionality and is suitable for mounting heights up to 40 feet. Once commissioned using a smartphone and the easy-to- use CLAIRITY app, nLight AIR equipped luminaries can be grouped, resulting in motion sensor and photocell group response without the need for additional equipment. Scheduled dimming with motion sensor over-ride can be achieved when used with the nLight Eclypse. Additional information about nLight Air can be found here. INSTALLATION Included mounting block and integral arm facilitate quick and easy installation. Stainless steel bolts fasten the mounting block securely to poles and walls, enabling the D-Series Size 1 to withstand up to a 3.0 G vibration load rating per ANSI C136.31. The D-Series Size 1 utilizes the AERISTM series pole drilling pattern (template #8). NEMA photocontrol receptacle are also available. LISTINGS UL Listed for wet locations. Light engines are IP66 rated; luminaire is IP65 rated. Rated for -40°C minimum ambient. U.S. Patent No. D672,492 S. International patent pending. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/ QPL to confirm which versions are qualified. International Dark-Sky Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page utilizing 3000K color temperature only. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/support/customer-support/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. 36 Introduction The Lithonia Lighting ARC LED wall-mounted luminaires provide both architectural styling and visually comfortable illumination while providing the high energy savings and low initial costs for quick financial payback. ARC2 delivers up to 6,500 lumens with a soft, non-pixelated light source, creating a visually comfortable environment. It offers integrated emergency battery backup options, including an 8W cold temperature option, making it suitable for pedestrian scale applications in any environment. NOTES 1 347V not available with E4WH, E8WC and SPD6KV. 2 FAO not available with DMG. One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020 Acuity Brands Lighting, Inc. All rights reserved. ARC2 LED Rev. 08/17/20 COMMERCIAL OUTDOOR ARC2 LED Architectural Wall Luminaire Catalog Number Notes Type Depth (D1):9.25" Depth (D2):7.5" Height:5" Width:14" Weight: (without options)11 lbs Hit the Tab key or mouse over the page to see all interactive elements. Specifications Series Package Color Temperature Voltage Options Finish ARC2 LED P1 1,500 Lumens P2 2,000 Lumens P3 3,000 Lumens P4 4,000 Lumens P5 6,500 Lumens 30K 3000K 40K 4000K 50K 5000K MVOLT 347 1 E4WH Emergency battery backup, CEC compliant (4W, 0°C min) 1 E8WC Emergency battery backup, CEC compliant (8W, -20°C min) 1 PE Button type photocell for dusk-to-dawn operation DMG 0-10V dimming wires pulled outside fixture (for use with an external control, ordered separately) 2 SPD6KV 6kV surge protection 1 FAO Field adjustable light output device. Allows for easy adjustment to the desired light levels, from 20% to 100% 2 DDBXD Dark bronze DBLXD Black DNAXD Natural aluminum DWHXD White DSSXD Sandstone DDBTXD Textured dark bronze DBLBXD Textured black DNATXD Textured natural aluminum DWHGXD Textured white DSSTXD Textured sandstone Ordering Information EXAMPLE: ARC2 LED P2 40K MVOLT PE DDBXD Luminaire Standard EM, 0°C Cold EM, -20°C Approximate Lumens (4000K) P1 P2 P3 P4 P5 ARC1 LED 4W --1,500 2,000 3,000 ---- ARC2 LED 4W 8W 1,500 2,000 3,000 4,000 6,500 ARC LED Family Overview W D1 H D2 Accessories Ordered and shipped separately. WSBBW DDBXD U Surface - mounted back box (specify finish) 37 Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Package System Watts 30K (3000K, 80 CRI)40K (4000K, 80 CRI)50K (5000K, 80 CRI) Lumens LPW B U G Lumens LPW B U G Lumens LPW B U G P1 11W 1,502 142 1 0 1 1,587 150 1 0 1 1,598 151 1 0 1 P2 16W 2,250 140 1 0 1 2,377 147 1 0 1 2,393 148 1 0 1 P3 24W 3,206 135 1 0 1 3,387 143 1 0 1 3,410 144 1 0 1 P4 30W 3,903 128 1 0 1 4,124 136 1 0 1 4,152 136 1 0 1 P5 51W 6,260 122 1 0 1 6,615 129 1 0 1 6,659 130 1 0 1 Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers To see complete photometric reports or download .ies files for this product, visit the Lithonia Lighting ARC LED homepage. Tested in accordance with IESNA LM-79 and LM-80 standards. One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020 Acuity Brands Lighting, Inc. All rights reserved. ARC2 LED Rev. 08/17/20 COMMERCIAL OUTDOOR Performance Data Lumen Output Ambient Lumen Multiplier 0°C 32°F 1.04 10°C 50°F 1.03 20°C 68°F 1.01 25°C 77°F 1.00 30°C 86°F 0.99 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 0 25,000 50,000 100,000 Lumen Maintenance Factor 1.0 >0.96 >0.93 >0.88 Performance Package System Watts Current (A) 120V 208V 240V 277V 347V P1 11W 0.090 0.055 0.049 0.046 0.045 P2 16W 0.141 0.081 0.072 0.064 0.059 P3 24W 0.202 0.117 0.103 0.091 0.079 P4 30W 0.280 0.162 0.144 0.128 0.095 P5 51W 0.471 0.272 0.239 0.212 0.158 Electrical Load Option Lumens E4WH 693 E8WC 1,413 Lumen Output in Emergency Mode (4000K, 80 CRI) Photometric Diagrams LEGEND 0.25 fc 0.5 fc 3.0 fc 1.0 fc ARC2 LED P3 40KARC2 LED P3 40K MH = 15ft Grid = 15ft x 15ft 38 One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020 Acuity Brands Lighting, Inc. All rights reserved. ARC2 LED Rev. 08/17/20 COMMERCIAL OUTDOOR The emergency battery backup is integral to the luminaire — no external housing required! This design provides reliable emergency operation while maintaining the aesthetics of the product. All emergency battery backup configurations include an independent secondary driver with an integral relay to immediately detect loss of normal power and automatically energize the luminaire. The emergency battery will power the luminaire for a minimum duration of 90 minutes (maximum duration of three hours) from the time normal power is lost and maintain a minimum of 60% of the light output at the end of 90minutes. Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety Code Section 7.9 The example below shows illuminance of 1 fc average and 0.1 fc minimum in emergency mode. Emergency Egress Options Emergency Battery Backup ARC2 LED 40K MVOLT E4WH Grid = 10ft x 10ft Mounting, Options & Accessories D = 6.5” H = 5” W = 11” E4WH and E8WC – Emergency Battery Backup D = 1.5” H = 4” W = 5.5” BBW – Standard Back Box FEATURES & SPECIFICATIONS INTENDED USE The clean architectural shape of the ARC LED was designed for applications such as hospitals, schools, malls, restaurants, and commercial buildings. The long-life LEDs and driver make this luminaire nearly maintenance-free. CONSTRUCTION The die-cast aluminum housing and door act as heat sinks to optimize thermal transfer from the light engine and driver to promote long-life. The die-cast door frame is fully gasketed with a one-piece solid silicone gasket to keep out moisture and dust, providing an IP65 rating for the luminaire. FINISH Exterior painted parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural aluminum, sandstone and white. Available in textured and non-textured finishes. OPTICS Recessed lens to cut off high angle light and reduce glare. Combination of diffused lens and reflector design has low surface brightness creating a visually comfortable environment with great distribution. LEDs are fully hidden from view to eliminate pixelization and harsh glare. The ARC LED has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine consists of high-efficacy LEDs mounted to metal-core circuit boards to maximize heat dissipation and promote long-life (up to L88/100,000 hours at 25°C). The electronic driver has a power factor of >90%, THD <20%. Luminaire is 0-10V dimmable. INSTALLATION The universal wall plate, supplied with the luminaire, fits multiple size junction boxes and supports it during wiring for easy installation. Built-in wet location wiring compartment on the luminaire to accommodate wiring connections for applications with no junction box. Design can withstand up to a 1.5 G vibration load rating per ANSI C136.31. LISTINGS CSA certified to U.S. and Canadian standards. Luminaire is IP65 rated. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified. International DarkSky Association (IDA) Fixture Seal of approval (FSA) is available for all products on this page utilizing 3000K color temperature only. WARRANTY 5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/support/customer-support/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. ARC2 LED 40K MVOLT E8WC Self-contained solution for clean aesthetic For surface conduit applications. 3/4" conduit entry holes. 39