Loading...
HomeMy Public PortalAboutRevised_28 Nyack_11_8_2019_REVPROJECT TITLE (OWNER ADDRESS SAME AS PROJECT ADDRESS) VICINITY MAP (NTS) CID II ABBREVIATIONS TALBE OF CONTENTS -' eP/� A° °ntst A.F.F. ABOVE FINISH FLOOR INSUL. INSULATION A-1 COVER PAGE ALUM ALUMINUM INT. INTERIOR A2-5 ARCHITECTURAL DRAWINGS ZAVEN ISHAKIAN / ARSEN JANIKIAN BSMT BASEMENT LAG. LAG BOLT S1-3 STRUCTURAL DRAWINGS BLDG BUILDING MFR. MANUFACTURER 28 NYACK STREET CPT CARPET MAX. MAXIMUM CLG CEILING MECH. MECHANICAL WATERTOWN, MA 02472 � CCONCRETE MIN. MINIMUM CMUMU CONCRETE MASONRY NO. NUMBER OWNER PHONE NUMBER: 617-416-7774 =� UNIT N.I.C. NOT IN CONTRACT DTL DETAIL NTS NOT TO SCALE DIM DIMINSION PNT. PAINT DIA DIAMETER PND. PAINTED PROJECT INFORMATION DWG DRAWING REQ'D REQUIRED DW DISHWASHER REF REFRIGERATOR ELEC ELECTRICAL RM. ROOM PARCEL ID: 502 710 EL ELEVATION SECT. SECTION SINGLE FAMILY HOME EQ. EQUAL SCHED. SCHEDULE ETR EXISTING TO REMAIN STD. STANDARD ZONE: S-6 =�� EXIST EXISTING STL. STEEL EXISTING BUILDING HEIGHT: 2 STORY, FINISHED BASEMENT EXT EXTERIOR TYP. TYPICAL F.A. FIRE ALARM VIF VERIFY IN FIELD GROSS SQUARE FOOTAGE EXISTING SECOND FLOOR: 614 SF Nyack Street F.B.O. FURNISHED BY OWNER W/o WITHOUT Z GROSS SQUARE FOOTAGE OF SECOND FLOOR PROPOSED: 1041 SF 16mi rive -home F.E. FIRE EXTINGUISHER WD. WOOD FL. FLOOR WH WATER HEATER Q FURR. FURRING PROJECT DESCRIPTION: o�~ GALV. GALVINIIZED _ �F GC GENERAL CONTRACTOR Z SECOND FLOOR ADDITION. TWO BEDROOM ONE BATH AT SECOND FLOOR TO BECOME THREE - Q,� GWB. GYPSUM BOARD Q _� HVAC HEATING VENTILATION BEDROOM AND 2 BATH. ALL NEW GROSS SQUARE FOOTAGE ADDED TO BE AT SECOND FLOOR. AND AIR CONDITIONING Z W U) rr Q Q C� SITE PLAN O GENERAL NOTES Z 3: z U < < 0 12 Z fr SIDE SETBACK NYACK STREET 10' GENERAL NOTES: 1. ALL CONSTRUCTION SHALL EXCEED THE LATEST EDITION OF CODES ADOPTED BY THE LOCAL GOVERNING AGENCIES. THESE00 Q W REQUIRED SIDE SETBACK SHALL INCLUDE MASSACHUSETTS BUILDING CODE, MASSACHUSETTS ELECTRIC CODE, MASSACHUSETTS PLUMBING CODE (n N Q (DRIVEWAY) REQUIRED AND ALL OTHER HEALTH AND SAFETY CODES, ORDINANCES, AND REQUIREMENTS ADOPTED BY GOVERNING AGENCIES. SIDEWALK 2. CURRENT BUILDING CODE, AS OF OCTOBER 20, 2017, IS THE 9TH EDITION. z 3. THESE PLANS ARE FOR GENERAL CONSTRUCTION PURPOSES ONLY. THEY ARE NOT EXHAUSTIVELY DETAILED NOR FULLY w PROPERTY LINE SPECIFIED. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO SELECT, VERIFY RESOLVE AND INSTALL ALL MATERIALS AND EQUIPMENT AS PER LOCAL CODES AND MANUFACTURERS SPECIFICATIONS. Q EXISTING 4. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE QUALITY CONTROL, AND CONSTRUCTION STANDARDS FOR THIS PROJECT. N COVERED 5. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL STRUCTURAL ENGINEERING, FOR ENTRY/STAIR CONSTRUCTION GRADING, AND FOUNDATION WORK PRIOR TO THE COMMENCEMENT OF THE WORK. THE CONTRACTOR SHALL HAVE THE STRUCTURAL ENGINEER REVIEW AND APPROVE IN WRITING THAT THE EXISTING FOUNDATION AND SITE Y DESIGN ARE IN CONFORMANCE WITH THE STRUCTURAL ENGINEERING DOCUMENTS. Q o 6. THE CONTRACTOR SHALL MAINTAIN THE SITE IN AN ORDERLY MANNER CONTINUOUSLY THROUGH THE PROJECT. m SITE NOTES: PERIMETER OF N LU 1. THIS PLAN SET IS NOT A SURVEY. IT IS PROVIDED FOR THE BUILDING AND SITE WORK LAYOUT ONLY. THE CONTRACTOR EXISTING HOUSE W W SHALL VERIFY ON SITE ALL GRADE, EXISTING IMPROVEMENTS, PROPERTY LINES, EASEMENTS, SETBACKS, UTILITIES AND 0 0 SUB STRUCTURES. WHERE DISCREPANCIES OCCUR CONTACT ARCHITECT. 2. FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. 3. WHERE DISCREPANCIES BETWEEN STRUCTURAL AND ARCHITECTS DRAWINGS OCCUR, CONTACT ARCHITECT. PROPOSEDINCREASED _ SECOND FLOOR FLOOR PLAN NOTES: AREALO 1. PRIOR TO CONSTRUCTION VERIFY ALL CRITICAL DIMENSION WITH EXISTING SITE CONDITIONS AND MANUFACTURERS SCALE: AS NOTED EXISTING SPECIFICATIONS. hi I CHIMNEY 2. ALL PLATE HEIGHTS DETERMINED BY PROPOSED STRUCTURAL MEMBERS AND CONNECTION SYSTEMS, TRUE PLATE HEIGHTS SHALL BE VERIFIED BY CONTRACTOR ACCORDING TO SIZES OF ACTUAL MEMBERS USED AND FIELD CONSTRUCTION Q PROPOSED INCREASED CONDITIONS. DATE: DESCRIPTION: z w CEILING HEIGHT AT EXISTING z 8.09.2019 PLANNING BOARD > SECOND FLOOR FLOOR ELECTRICAL NOTES: o I AREA NOTE: WALL OF PROPOSED NEW 1. ALL ELECTRICAL WORK IS TO BE BIDDER DESIGNED W I I SECOND FLOOR ADDITION TO ALIGN 2. VERIFY ALL RECEPTACLE, SWITCH, AND FIXTURE LOCATIONS WITH OWNER PRIOR TO INSTALLATION WIr WW z WITH EXISTING FIRST FLOOR WALL AT a a STREET SIDE. MECHANICAL AND ENERGY NOTES: W EXISTING HOUSE EXTENDS PAST 1. ALL MECHANICAL WORK IS TO BE BIDDER DESIGNED REAR SETBACK LINE BY 5.1 2. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS OR OTHER ENTRY/STAIR PROPOSED INCREASED SUPPLEMENTARY DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT SECOND FLOOR FLOOR I 3. VENTILATION OF ALL AREAS SHALL BE IN COMPLIANCE WITH LOCAL BUILDING CODES ARE 4. STRETCH ENERGY CODE COMPLIANCE TO BE THE RESPONSIBILITY OF THE CONTRACTOR I 0 I PLUMBING NOTES: 1. ALL PLUMBING WORK IS TO BE BIDDER DESIGNED EXIST. EXISTING DECK 2. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND THE CONSULTING ENGINEERS OR OTHER SEAL: BASEMENT BELOW PROPOSED SUPPLEMENTARY DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT ACCESS STAIR SECOND FLOOR ADDITION DEMOLITION NOTES: 1. TEST FOR LEAD PAINT BEFORE DEMOLITION BEGINS 2. DEMOLITION WORK INCLUDES BUT NOT LIMITED TO WHAT IS SHOWN ON DEMO PLANS 3. SALVAGE ALL WINDOWS AND DOORS NOT USED IN NEW SPACE EXISTING SETBACK 4. CONSULT WITH OWNER ABOUT REUSE FIXTURES BACKYARD LINE 5. CONSULT WITH STRUCTURAL ENGINEER BEFORE REMOVING PORTION OF EXTERIOR WALL OR REMOVING ANYTHING THAT COULD COMPROMISE EXISTING WOOD OR FOUNDATION STRUCTURE. Y EXISTING ONE STORY I Q W SECTION 5.04 TABLE OF DIMENSIONAL REGULATIONS GARAGE m N W D (n Cif Min. Lot Min. set (ftj(p} Max. Max. Min. Lot Min. District Size Frontage Building Impervious Max. Height Area Per Max. FAR Open W W (s,f.y (ft) Front Side Rear coverage Coverage (ftlstories) Dwelling Space % % Unit s.f. % TITLE C) I — � 2110 (e) �20 25 85 35r2.5 (j]� 15 5-6 _ fi,000 _ fi5 25 1 _ _ _. _ A-001.00 PROPERTY LINE 1 OF 3 EXISTING FIRST FL. PLAN O SCALE: 1/4" = V-0" FIRST FLOOR DEMO PLAN SCALE: 1/4" = V-0" 40 8'-3" EXIST. FRONT ENTRY O O I I I I I I O O UP = REMOVE PORTION OF T WALL TO ALLOW FOR INSTALLATION OF EXIST. DINING LIVING ROOM CONTINUOUS POST CHIMNEY FROM BEAM ABOVE z a REMOVE CHIMNEY ElZ N --------- DN N POST TO CONTINUE ~ EXIST. TO BASEMENT AT N 0 CHIMNEY THIS LOCATION, �J W DEMO 2'X2' HOLE FOR (n Q REMOVE PORTION OF NEW POST FOOTING (r WALL TO ALLOW FOR AT BASEMENT LEVEL, Q (n .. T INSTALLATION OF SEE STRUCTURAL z ct) T KITCHEN BATH O O BEDROOM 1 CONTINUOUS POST O O PLANS \ z U O O ROOM 1 FROM BEAM ABOVE O O Q 0 D z REF o REF o Q 00 LLI z LLI Q _ _ N Lo EAT IN KITCHEN Lo co DECK co EXIST. STAIR 1' 9" m===o 18'-8" ° EXIST. EXTERIOR EXIST. STAIRS DOWN TO UNCOVERED BASEMENT LEVEL WOOD DECK Q3 EXISTING SECOND FL. PLAN SCALE: 1/4" = V-0" SECOND FLOOR DEMO PLAN SCALE: 1/4" = V-0" SCALE: AS NOTED DRAWN BY: - 32-2' REVIEWED BY: DATE: DESCRIPTION: 8.09.2019 PLANNING BOARD EXISTING CHIMNEY TO REMAIN r---------------------------------� _ — — — — — — ____________________ � II EXISTING CHIMNEY REMOVE CHIMNEY II I TO REMAIN � II T T I ' II ❑ LL I BEDROOM 3 BEDROOM 2 REMOVE EXISTING SHED III I ROOF AND WALLS TO III I I SEAL: T TOP PLATE OF FIRST L� �' cw FLOOR FRAMING �� n n J_ I I CD I II III ' ��;I O ' 11 � 11 1� 1 - I L -41 1 I 1 � [I :D i I �' 1 `--- - --� L�==- J - ---- -- ----j' 1 —------------ ----------�__-----�—j HOME RENOVATION TO: 1 82 JENSEN STREET WATERTOWN, MA 02472 REMOVE PORTION OF BACK ENTRY ROOF TO ' __X ACCOMMODATE NEW NOTES: EXISTING AND ROOF WITH NO VALLEY 1. DEMOLITION WORK INCLUDES BUT IS NOT LIMITED TO WORK SHOWN DEMO PLANS ON DEMOLITION DRAWINGS. REMOVE ROOFING 2. CONSULT WITH OWNER TO DETERMINE SALVAGE OF WINDOWS FIXTURE AND EQUIPMENT REMOVED FROM HOME.A-002.00 '-1 " 2 8 0 MATERIAL TO EXPOSE EXISTING ROOFS JOISTS - CONFIRM JOIST SIZE WITH ENGINEER AND ARCHITECT 2 OF 2 PROPOSED FIRST FLOOR PLAN SCALE: 1/4" = V-0" PROPOSED BASEMENT PLAN SCALE: 1/4" = V-0" 40'-5" N CV 32'-2" looe 31'-7" UP 10'-11 " 3' 0110 16'-2" EXIST. FRONT NEW ENTRY WINDOWS ALIGN (3) 7'-4" VIF 6'-8" 4'-3" EXISTING F_ O O WINDOW ON SECOND FL. ALIGN NEW WALL ELECTRICAL SERVICE 1 FRONT OF HOUSE WITH WALL ENTRY LOCATION 3'-10" WITH FIRST FL. BELOW AT FIRST MATCH WINDOWS SEE 12 1 FLOOR EXIST. 13 14 ELEVATION 4) o U c) Q w L EXISTIN CHIMNEY Q 1 (EXTENDED) UP � T T I 0 T a O T DINING LIVING ROOM 1 o - T T PATCH WALL AT FORMER CHIMNEY T 11 r BEDROOM 1 z w O w W Q LOCATION BEDROOM 2 Q ^ EXIST. CHIMNEY D� U DN Z Q<OO CL D1 D2 CL CL Lo Z cr T Lo _ CV L Q 00 W T 1 N M D12 D12 co N ~ r KITCHEN O O BATH DEN 1'I D5 ROOM 1 2 Z D 10 BATHROOM 2 3'-6" ` I 15'-8" CT W EXISTING ROOF 5 ALIGN ALL WITH Q BELOW ° CL pg WALL EXISTING WALL N REF o - . ' ° . BELOW T T � ° D2 BEDROOM3 T - c\' (MASTER)co EXIST. DECK T bo D 4L T0) T Lo co EAT IN KITCHEN REMAIN BATHROOM D4 -1 DECK co 3 f L co EZ / EXIST. AC F-h — CONDENSER 6 UP — — — — — — — — — — — — — — — — — — — — — — — DN o NEW POST SEE STRUCTDWGS.op 8 4'-7" 5'-1" 2'-10" 7C6 EQ. EQ. 2'-10" SCALE: AS NOTED . VERIFY ALL DRAWN BY: PROPOSED ADDITION INFILL EXISTING DIMENSIONS 10'-1" 20'-6" ABOVE ROOF TO DRAIN CONSULT WITH REVIEWED BY: ARCHITECT DATE: DESCRIPTION: EXISTING EXTERIOR 7'-10" 13'-11" UP 18'-5" 32'-2" 8.09.2019 PLANNING BOARD STAIRS oor ALIGN WALL WITH VERIFY ALL EXISTING WALL WALL EXISTING BACK � _ EXISTING WALL DIMENSIONS NEW WALL WALL OF HOUSE N NEW WALL CONSULT WITH ARCHITECT INTERIOR NOTES: PROJECT NOTES: INTERIOR DOORS: MIN SIZES: • ELECTRICAL NOTES ARE AND CALL OUTS OF ELECTRICAL COMPONENTS ARE SUGGESTIVE ONLY FOR • ALL INTERIOR DOORS TO HABITABLE ROOMS SHALL BE MIN. 30" (2-6") NOMINAL SIZE PLANNING PURPOSES. ELECTRICIAN TO PROVIDE A COMPLETE BRANCH CIRCUIT WIRING SYSTEM PER • BATHROOM DOORS SHALL BE MIN 28" (24") NOMINAL SIZE. NEC. • ALL INTERIOR DOORS SHALL HAVE A MINIMUM NOMINAL HEIGHT OF 6-6" . ELECTRICIAN TO DO A WALK-THROUGH WITH OWNERS OR OWNERS REP. BEFORE INSTALLATION TO SEAL: VERIFY DEVISE LOCATIONS / DETAILS FLOORING: • HVAC SYSTEM TO BE FORCED AIR. LOCATION OF A/C CONDENSER SHOWN ON PLAN. • UNDERLAYMENT SHALL BE INSTALLED UNDER ALL FLOORING ACCORDING TO . THE CONTRACTOR SHALL NOTIFY THE ENGINEER WHEN, IN THE COURSE OF CONSTRUCTION OR ACCEPTED INDUSTRY STANDARDS DEMOLITION, CONDITIONS ARE UNCOVERED WHICH ARE UNANTICIPATED OR OTHERWISE APPEAR TO PRESENT A DANGEROUS CONDITION. GLASS: TEMPERED GLASS AT ALL BATHROOM GLASS PARTITIONS AS PER CODE. ROOF: • NEW ASPHALT ROOF, NEW AND EXISTING ROOF. PROVIDE ICE AND WATER SHIELD AS REQURED CHIMNEYS: • NEW BRICK TO MATCH EXISTING BRICK. CONSULT WITH OWNER/ARCHITECT BEFORE STARTING WORK TO GET APPROVAL OF BRICK COLOR/QUALITY. SIDING: • NEW SIDING TO MATCH EXISTING. CONSULT WITH OWNER TO VERIFY IF NEW SIDING IS REQUIRED AT WHOLE HOUSE. PROPOSED FLOOR INTERIOR FINISHES: PLANS • CONSULT WITH OWNER FOR INTERIOR FINISHES A-003-00 2 OF 2 EXISTING FRONT ELEVATION SCALE: 1/4" = V-0" EXISTING REAR ELEVATION SCALE: 1/4" = V-0" Z a 0 oI LilZ CV zwo � �Q Q C/) ---- �zz 3: Z U Q<O z00 a w cf) Q Q3 EXISTING RIGHT ELEVATION SCALE: 1/4" = V-0" EXISTING LEFT ELEVATION SCALE: 1/4" = V-0" Z W Q N I SCALE: AS NOTED DRAWN BY: - REVIEWED BY: DATE: DESCRIPTION: 1 1 8.09.2019 I PLANNING BOARD I SEAL: EXISTING ELEVATIONS A-004.00 2 OF 2 PROPOSED FRONT ELEVATION SCALE: 1/4" = V-0" PROPOSED REAR ELEVATION SCALE: 1/4" = V-0" EXTEND CHIMNEY EXTEND CHIMNEY LJ r7 lf- "T An 2ND FLOOR 3: 0 2ND FLOOR z CEILING W Z LL CEILING Q _ i Z N L—J 1 O MODIFY ROOF OVER EXISTING (y TZ ENTRY w w O N 2ND FLOOR � N 2ND FLOOR C - FINISH FLOOR FINISH FLOOR G o T W cn co w T 3: U QQO azw _ 00 1 ST FLOOR 1 ST FLOOR �_ Q FINISH FLOOR FINISH FLOOR I 7-Z z w Q K—Al A— N STRUCTURAL DWGS. BAY WINDOW kIm AND FRONT ENTRY v 1 '" vI FACADE TOMATCHSIZE) 0 PROPOSED RIGHT ELEVATION SCALE: 1/4" = V-0" 4 PROPOSED LEFT ELEVATION SCALE: 1/4" = V-0" NEW BUILDING AREA EXTENDING EXISTING HOUSE / PROPOSED PAST 25' FRONT SETBACK LINE SECOND FLOOR ADDITION r` CODE COMPLAINT FOUNDATION NEW BUILDING AREA EXTENDING EXISTING HOUSE / PROPOSED NEW SECOND PAST 25' FRONT SETBACK LINE SECOND FLOOR ADDITION FLOOR ADDITION EXTEND CHIMNEY '�' uMr_UT AQ SCALE: AS NOTED DRAWN BY: - REVIEWED BY: DATE: DESCRIPTION: 8.09.2019 PLANNING BOARD SEAL: PROPOSED ELEVATIONS A-005.00 2OF2