HomeMy Public PortalAbout2016-10-19 minutes MINUTES International Residential and Energy Conservation Codes TECHNICAL SUB-COMMITTEE of the City of Jefferson Code Review Steering Committee October 19, 2016 COMMITTEE MEMBERS PRESENT: COMMITTEE MEMBERS ABSENT: Dan Klindt, Chair Jude Markway Paulette Kreter,Vice Chair Lynn Gastineau Dean Holtmeyer Bob Scruggs Dan Roling EX-OFFICIO MEMEBERS PRESENT: Public Present: Mark Luebbering, County Mike Crocker Brian Allen,City of Jefferson, PPS Rick Vaughan Larry Burkhardt, City of Jefferson, PPS 1. Call to Order Chair Dan Klindt called the meeting to order at 2:03 pm in the Small Conference Room of City Hall. A quorum was present. 2. Review minutes for approval of meeting held October 5,2016. The minutes for the meeting were reviewed and approved by the committee. 3. Old Business—Review list of proposed amendments for the 2015 IRC. The list of proposed amendments was reviewed with no changes. 4. Start review of inspection list,swimming pools and appendix. Swimming pools were discussed first with representatives from Vaughan Pools. After much discussion and reviewing the IRC, requirements for electrical are located in the IRC. Other pertinent requirements(e.g. barriers) are in the ICC International Swimming Pool and Spa Code (ISPSC). Another item discussed was the residential building checklist. The proposed checklist was accepted. 5. Determine next chapters for review The next meeting will start to review the list of proposed amendments and any appendices for adoption. Members will also receive copies of the ISPSC. 6. New Business None was discussed. 7. Public Comments No public comments were presented. 8. Next meeting date?'"November 2nd? The next meeting will be will be from 2 to 4 pm, November 2, 2016. 9. Adjourn The meeting adjourned at 3:15 p.m. Proposed 2015 International Residential Code Amendments: 1. Section R302.5.1-delete"equipped with a self-closing device"from the end of this section. 2. Section R302.11-delete item 4(fire blocking around vents, pipes,etc.) 3. Section R302.13-add the following exceptions: a. "5.Open-web wood truss floor joists with draft stopping per 1,000 square feet." b. "6. Closed-web wood joists with one (1) hour fire treating." 4. Section R303.4-needs more information-Columbia is using a whole-house mechanical ventilation system. What do we want to do? 5. Section R303.6-Add Exception "1. Bathroom exhaust fans may be exhausted into a soffit vent if composed of approved materials as determined by the Building Official." 6. Figure R307.1-Add the following:Water closet: All water closets shall be spaced at least fifteen (15) inches from the centerline of the fixture to any wall or plumbing fixture, except the centerline of the water closet may be spaced twelve(12) inches if located next to a bathtub/shower unit. 7. Section R309.5-delete section-garage sprinklers are required if walls are built to Table R302.1(2) 8. Section R311.7.5.1-add exception-"3.Closed risers are not required on exterior stairs where the riser is less than 10'above grade." 9. Section R312.2-delete section-window fall protection 10. Section R313.1-delete- townhouse fire sprinkler 11. Section R313.2-delete-One and Two family sprinklers (NOTE: The JCFD has requested that the committee reconsider this recommendation after a demonstration system has been installed into a Habitat for Humanity home.) Section R313.3-add- A builder of one or two family dwellings or townhouses shall offer to any purchaser,on or before the time of entering into the purchase contract,the option at the purchaser's cost to install or equip an automatic fire sprinkler system in the dwelling or townhouse. Notwithstanding any other provision of the law to the contrary, no purchaser of such a one or two family dwelling or townhouse shall be denied the right to choose or decline an automatic fire sprinkler in such dwelling or townhouse being purchased. 12. Section R314.4-replace first sentence of 2"paragraph- "Exception: Interconnection of smoke alarms in existing areas may use wireless technology or shall not..." 13. Section R322-Flood resistant construction-shall be reviewed by City storm water engineer to see if there are any conflicts with existing City codes. Recommendation will be forthcoming. 14. Section R403.1.3.3-Delete seismic categories. This will require steel reinforcement in turned-down footings. 15. Section R404.4-Add standard concrete designs for retaining walls and suspended garage slabs. Retaining wall designs should include lateral tie-backs and#4 bars for standards. 16. R602.3.1,Add the following sentence to the end of Exception number 2: "Alternatively, 2"x 6" No.2 grade studs supporting a roof and floor load with not more than 10' of tributary length shall have a maximum stud height of 14'." 17. Chapter 11-Energy Efficiency-use the 2009 version of this chapter in lieu of the 2015 version.