Loading...
HomeMy Public PortalAbout2016-12-21 packet Notice of Meeting&Tentative Agenda ,�.0 i1&I City of Jefferson, Missouri Building and Energy Conservation Codes TECHNICAL SUB-COMMITTEE of the Ad Hoc Committee on Building Construction Codes Wednesday, December 21, 2016 9:30 a.m. — 11:30 a.m. Multipurpose Room —lower level— City Hall Annex 305 E. Miller TENTATIVE AGENDA 1. Call to order 2. Review and approve minutes of meeting held December 7, 2016. 3. Old Business -Review list of proposed amendments 4. Start review of Chapters 12 and 13. 5. New business — next meeting assignment 6. Public Comments 7. Next meeting date? —January 4th? 8. Adjourn Individuals should contact the ADA Coordinator at(573) 634-6570 to request accommodations or alternative formats as required under the Americans with Disabilities Act. Please allow three business days to process the request. MINUTES International Building and Energy Conservation Codes TECHNICAL SUB-COMMITTEE of the City of Jefferson Code Review Steering Committee December 7, 2016 COMMITTEE MEMBERS PRESENT: COMMITTEE MEMERS ABSENT: Larry Brandhorst,Chair Randy Allen,Vice Chair Emad Faddoul Corey Falter Carrie Brixey Andy Bonderer Greg Bowman EX-OFFICIO MEMBERS PRESENT: Larry Burkhardt 1. Call to Order Chair Larry Brandhorst called the meeting to order at 9:36 am. 2. Review and Approve minutes of the November 16,2016 meeting. The committee approved the minutes. 3. Old Business—Review list of proposed amendments None were noted for changes. 4. Continue review of Chapter 9 The committee had a lengthy discussion of fire sprinklers. The final decision was to accept Chapter 9 without amending the fire sprinkler or other requirements. It was proposed to amend the fire extinguisher requirement to match the fire code to require UL listing. 5. New Business—next meeting assignment The committee will start review of Chapter 12 and 13 6. Public Comments None were made. 7. Next Meeting Date?"'December 21St? The next meeting date will be from 9:30 am to 11:30 am, December 21, 2016. 8. Adjourn The meeting adjourned at 11:29 am. Proposed Amendments to the 2015 International Building Code: 1. Section 305.2.3— Replace "five" with "ten"throughout this section. 2. Section 308.6.4— Replace "five" with "ten"throughout this section. 3. Section 402—Does this Section include "strip malls?" 4. Section 420.5—Review automatic sprinkler system for Group R occupancies. 5. Current City Code for Chapter 9: Section 903.2.8: Delete this Section and insert in lieu thereof the following: Section 903.2.8: Group R-1, An automatic sprinkler system shall be provided throughout buildings with a R-1 fire area. Section 903.2.8.a: Group R-2, An automatic sprinkler system shall be provided throughout all buildings with Group R-2 fire area where more than two stories in height, including basements, or where having more than 10 dwelling units EXCEPTION: A residential sprinkler system installed in accordance Section 903.3.1.2 shall be allowed in buildings,or portions thereof,of Group R-2 Section 903.2.8.b: Group R-4, An automatic sprinkler system shall be provided throughout all buildings with a Group R-4 fire area. 6. Section 906.11- Sale of fire extinguishers: Fire extinguishers that do not carry an Underwriter's Laboratory label and rating shall not be offered for sale or trade within the City. 7. Section 1011.4 — Measurement of walk line? Does this this include the entire width of the stair or clear width? 8. Section 1015.2 — Guard should also be provided for site features where people still have a chance of falling.