Loading...
HomeMy Public PortalAbout2002_10_22_r175 - Modifying the Adopted Water System Master PlanThe Town of Leesburg, trg ma RESOLUTION NO. A RESOLUTION: PRESENTED Oetnher 22; 2002 ~ ADOPTED Oetnher 22; 2002 MODIFYING THE ADOPTED 1987 WATER SYSTEM MASTER PLAN WHEREAS, the 1987 Water System Master Plan, as adopted by Council in October 1988, provided a recommendation for the location and size of future water system improvements, referenced as Altemative No. 1 in the plan and further amended to modified Alternative No. 1 by Resolution No. 93-206 on October 26, 1993 changing the sewer shed boundaries of lower and upper Cattail Branch; and WHEREAS, the October 2002 "Water Tank Siting Analysis and Low Water Pressure Evaluation" report, as prepared by the town's consultant, Whitman, Requardt and Associates L.L.P., recommends minor modifications to Alternative No. 1 necessary to address changes in the town's demographics, development and water distribution system over the past 15 years; and WHEREAS, the recommended modification includes construction of a 1.5 million gallon (MG) Main Pressure Zone water storage tank adjacent to the Carr Elevated Storage Tank, two elevated water storage tanks in the Sycolin Pressure Zone totaling 2.5 MG (one, previously approved, at High Point Development and the other at the Loudoun County Shellhom property) and creation of a mini-pressure zone in Woodlea Manor Subdivision; and WHEREAS, the Director of Utilities and Director of Engineering and Public Works recommend the described modification. THEREFORE, RESOLVED by the Council of the Town of Leesburg in Virginia as follows: A RESOLUTION: -2- MODIFYING THE ADOPTED 1987 WATER SYSTEM MASTER PLAN SECTION I. The Water Sewer Master Plan is modified as follows: (a) Main Pressure Zone - one additional 1.5 MG tank adjacent to Carr tank with Rehau site as a back-up recommendation. (b) Sycolin Pressure Zone - two tanks with a combined capacity of 2.5 MG with one tank at High Point followed by Shellhom for the second future tank site. (c) Westem Pressure Zone - creation of a mini-zone for Woodlea Manor subdivision. SECTION II. Section II of Resolution No. 88-191 is hereby rescinded. PASSED this 22nd day of October 2002. Kristen C. Umstattd, Mayor Town of Leesburg ATTEST: C~rk of Council R02:watersysmasteqalanmodif 10"--~ WESTERN PRESSURE ZONE MYERS-- WELL HOSPITAL TANK MAIN PAXTON ZONE ~ARBS PERR~ Carr Tank 02 ',ARR TANK ~ LEGEND -- ROAD EXISTING WATER LINES ~-~ CORPORATE BOUNDARY [] EXISTING BOOSTER PUMP STATION · PROPOSED BOOSTER PUMP STATION ..........PROPOSED SERVICE ZONE O PROPOSED TANK ~m~m PROPOSED TRANSMISSION LINE IMPROVEMENTS ~ PROPOSED LINE IMPROVEMENTS e r FOR ALTERNATWE NO. 1 · Proposed Tank WATER TREATMENT PLANT V Tank Removed from Selected Alternative No. 1 Hogback M Tank 1000 0 1~00 2000 CO00 4000 fELLS /..' Rte. 643 Tank~. ROUTE 643 PRESSURE ZONE I ~uture Proposed ................ ~"["l~te 643 Tank #2 TOWN OF LEESBURG, VIRGINIA WATER AND SEWER MASTER PLAN WATER SYSTEM IMPROVEMENTS SELECTED ALTERNATIVE NO. 1 (Modified}