Loading...
HomeMy Public PortalAbout1999 State Revolving Fund Amendment 2 Agreement CS12085002P - Collection Sewer System.tifjeb Bush Governor Department of Environmental Protection NOV 2 2 1999 Twin Towers Office Building 2600 Blair Stone Road David B Struhs Tallahassee Florida 32399 2400 Secretary CERTIFIED MAIL RETURN RECEIPT REQUESTED Mr C Samuel Kissinger Village Manager Village of Key Biscayne 85 West "'chi) a St eet Key Biscayne Flonda 33149 Re CS12085002P — Village of Key Biscayne Collection Sewer System Dear Mr Kissinger We are pleased to provide financing under the State Revolving Fund loan program for construction of your collection sewer system Enclosed is one copy of Amendment 2 to your loan The amendment is now in effect We congratulate you and your staff on your efforts and are pleased that we can continue working with you on this project If we may be of further assistance please contact Jerry Herting at 850/488 8163 or write to Mr Herting Mail Station 3505 at the letterhead address Sincerely '2__ avi� Struhs Secretary DBS/gh/h Enclosure cc Peter Kory — Key Biscayne Mike Bechtold — DEP/West Palm Beach Protect Conserve and Manage Honda s Environment and Natural Resources P ted on recycled pap STATE REVOLVING FUND AMENDMENT 2 TO LOAN AGREEMENT CS12085002P VILLAGE OF KEY BISCAYNE This amendment is executed by the STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (Department) and the VILLAGE OF KEY BISCAYNE FLORIDA (Local Government) existing as a local government agency under the laws of the State of Florida WITNESSETH WHEREAS the Department and the Local Government entered into a State Revolving Fund Loan Agreement, Number CS 12085002P authorizing a Loan amount of $693 000 excludmg Capitalized Interest and WHEREAS the Local Government is entitled to additional fmancmg for construction related activities in the amount of $6 798 000 excluding Capitalized Interest and WHEREAS provisions for a Grant Allocation Assessment, as authonzed by Section 403 1835 of the Florida Statutes and related revisions to the Loan Agreement are needed and WHEREAS an mterest rate and a Grant Allocation Assessment rate are to be established for the additional financing amount awarded in this amendment and WHEREAS an Incremental Loan Service Fee shall be paid by the Local Government for the additional financing provided by this amendment and WHEREAS the Semiannual Loan Payment amount and the Project costs need revision to reflect adjustment in the Loan amount and WHEREAS the Project schedule certain definitions and other provisions of the Agreement need revision and several provisions need to be added to reflect financing of construction related activities NOW THEREFORE the parties hereto agree as follows ' St<bsections 10"4) 01(6) 1 01(") 1 0'('Z) 10'('4` and' 01(15) of the Agreemert are revised as follows (4) Capitalized Interest shall mean indebtedness accruing on the Loan before the 20 year repayment period begins and it is included as part of the Loan principal Capitalized Interest is not disbursed to the Local Government, but it will be amortized via periodic Loan repayments to the Department as if it were actually disbursed Capitalized Interest will be computed at the interest rate set for the origmal Loan amount and at the combined rate of interest and Grant Allocation Assessment set for any incremental Loan amount awarded by amendment It accrues and is compounded annually from the time when disbursements are made until six months before the first Semiannual Loan Payment is due (6) Loan shall mean the amount of money to be loaned pursuant to the Agreement and subsequent amendments (11) Pledged Revenues shall mean the specific revenues pledged as security for repayment of the Loan and shall be the Revenues as defined 111 Subsection 1 01(14) as amended There are no prior hens on these Revenues (13) Project shall mean the planning administrative and engineering work necessary for the Local Government to qualify for a State Revolving Fund construction loan and the works financed by the additional funding provided by this amendment, consistmg of fmushmg all labor materials and equipment to construct a sewer collection system in accordance with the plans and specifications accepted by the Department for the contract entitled the Village of Key Biscayne Sanitary Sewer System The work will be performed under three contracts The Project is in agreement with the Sanitary Sewer Collection System Study for the Village of Key Biscayne dated October 1997 Approval of this Project is provided by the Florida Categorical Exclusion Notification dated July 10 1998 The Project is not an Equivalency Project as defined in Chapter 62 503 Florida Admuustrative Code (14) Reverues sl-ail metal the `olloi rig (a) The Special Assessment Proceeds which shall include prmcipal, interest and penalty collections of the special assessments levied for the Project in accordance with the Local Government s Ordmance No 93 3 and (b) State Revenue Sharmg Funds which shall mean all distributions and income or earnings received by the Local Government under the State revenue sharmg program and (c) Revenues allocated and budgeted for Loan repayment from the Local Government s General Fund and (d) All interest and earnings on moneys on deposit m the State Revolving Loan Repayment Account (15) Semiannual Loan Payment shall mean the payment due from the Local Government to the Department at six month intervals and it is comprised of principal interest and Grant Allocation Assessment In addition the Incremental Loan Service Fee and all associated interest are deducted from the first two payments 2 Section 1 01 of the Loan Agreement is revised to include the following definitions Grant Allocation Assessment shall mean an assessment expressed as a percent per annum accruing on the unpaid prmcipal balance (including Capitalized Interest) of the additional financing p*ov ded b} this amendment and ar fi ti*e amendn'erts I* computed similarly to the way interest charged on the Loan is computed and is included m the Semiannual Loan Payment The Department will use Grant Allocation Assessment moneys for making grants to financially disadvantaged small communities pursuant to Section 403 1835 of the Florida Statutes Incremental Loan Service Fee shall mean an origination fee assessed for the additional financing provided by this and any subsequent amendments The fee shall be paid to the Department by the Local Government (The Loan Service Fee paid on the previously authorized financing is included in the Loan principal The Incremental Loan Service Fee is not ) State Revolvmg Loan Repayment Account shall mean the account into which the Local Government shall deposit General Fund allocations for Loan Repayment and all Special Assessment Proceeds 2 3 Sections 3 01 and 3 04 of the Loan Agreement are deleted and replaced as follows 3 01 MONTHLY ESCROW ACCOUNT The Local Government shall establish a monthly escrow account with a Depository and begin making Monthly Loan Deposits no later than the date set forth in Subsection 4 01(11) as amended (see page 8 of this amendment) Beginning six months prior to each Semiannual Loan Payment, the Local Government shall make six Monthly Loan Deposits The first five deposits each shall be at least equal to one sixth of the Semiannual Loan Payment The sixth Monthly Loan Deposit shall be at least equal to the amount required to make the total on deposit m the monthly escrow account equal to the Semiannual Loan Payment amount taking into consideration investment earnings credited to the account pursuant to Section 3 02 Any month in which the Local Government fails to make a required Monthly Loan Deposit the Local Government s chief financial officer shall notify the Department of such failure In addition, the Local Government agrees to budget by amendment if necessary payment to the Depaitinent from other legal y avanable funds a'1 staiir oeco-r ig aue oefore the same become delmquent This requirement shall not be construed to give supenonty to the Department s claim on any revenues over prior claims of general creditors of the Local Government nor shall it be construed to give the Department the power to require the Local Government to levy and collect any revenues other than Pledged Revenues 3 04 LOAN REPAYMENT RESERVE ACCOUNT A Loan Repayment Reserve Account shall be established with a Depository The Local Government shall deposit into the account the ieserve amount identified in Subsection 4 01(15) page 8 of this amendment, no later than the date set forth therein Loan proceeds are provided for a portion of the deposit The Local Government shall use its own funds for the remamder of the required deposit 4 Article III of the Loan Agreement is amended to include the following sections 3 09 STATE REVOLVING LOAN REPAYMENT ACCOUNT The Local Government shall establish the State Revolvmg Loan Repayment Account with a Depository and shall deposit all Special Assessment Proceeds and allocations for Loan repayment from the general fund into the account Moneys on deposit in the account shall be invested pursuant to the laws of the State of Florida The investment earnings shall be credited to the account The withdrawal of moneys from the State Revolving Loan Repayment Account shall be for the purpose of making Monthly Loan Deposits for Loan repayment or for discharging the Local Government s obligations pursuant to Section 7 01 5 Section 4 03 LOAN DISBURSEMENTS is revised by deleting the preconstruction disbursement schedule The Department will provide actual disbursement data in account statements 6 Section 6 01 is deleted in its entirety and replaced as follows PLEDGED REVENUE COVERAGE The Local Government shall collect Pledged Revenues each fiscal year which together with the amount on deposit in the State Revolving Loan Repayment Account at the beginning of the fiscal year shall equal or exceed 1 20 tunes the sum of the Semiannual Loan Payments due in such fiscal year 7 Section 6 02 RESERVED PLEDGED REVENUES is hereby deleted m its entirety 3 8 Section 7 01 is deleted in its entirety and replaced as follows DISCHARGE OF OBLIGATIONS All payments required to be made under this Agreement shall be cumulative and any deficiencies in any Fiscal Year shall be added to the payments due m the succeeding year and all years thereafter until fully paid Payments shall continue to be secured by this Agreement until all of the payments required shall be fully paid to the Department If at any time the Local Government shall have paid or shall have made provision for the timely payment of the entire principal amount of the Loan interest and Grant Allocation Assessment the pledge of and lien on, the Pledged Revenues to the Department shall be no longer in effect Deposit of sufficient cash securities or mvestments authorized by law from time to time may be made to effect defeasance of this Loan However the deposit shall be made m irrevocable trust with a banking institution or trust company for the sole benefit of the Department There shall be no penalty imposed by the Department for early retirement of this Loan 9 The following article is added to the Agreement ARTICLE X CONSTRUCTION CONTRACTS INSURANCE AND DISBURSEMENTS 10 01 AUTHORIZATION TO AWARD CONSTRUCTION CONTRACTS The following documentation is required to receive the Department s authorization to award construction contracts (1) Proof of advertismg (2) Award recommendation bid proposal and bid tabulation (certified by the responsible engmeer) (3) Certified copy of the Local Government s tentative award resolution (4) Certification of compliance with the conditions of the Department s approval of competitively or noncompetitively negotiated procurement 10 02 SUBMITTAL OF CONSTRUCTION CON 1 RACT DOCUMENTS After the Department s authorization to award construction contracts has been received the Local Government shall submit contractor insurance certifications and notices to proceed with construction 10 03 INSURANCE REQUIRED The Local Government shall cause the Project, as each part thereof is certified by the engineer responsible for overseeing construction as completed (hereafter referred to as Revenue Producing Facilities J to oe insured by an insurance company o companies licen,eo to do busmess m the State of Florida against such damage and destruction risks as are customary for the operation of Revenue Producmg Facilities of like size type and location to the extent such insurance is obtamable from time to tune against any one or more of such risks The proceeds of insurance policies received as a result of damage to or destruction of the Project or the other Revenue Producing Facilities shall be used to restore or replace damaged portions of the facihties If such proceeds are insufficient the Local Government shall provide additional funds to restore or replace the damaged portions of the facilities Repair construction or replacement shall be promptly completed 10 04 ENGINEERING SERVICES A professional engineer registered in the State of Florida shall be employed by or under contract with the Local Government to oversee construction 4 10 05 CONSTRUCTION DISBURSEMENTS Disbursements shall be made directly to the Local Government for reimbursement of the mcurred construction costs and related services Disbursements for materials labor or services shall be made upon receipt of the following (1) A completed disbursement request form signed by the Authorized Representative Such requests must be accompanied by sufficiently itemized summaries of the materials labor or services to identify the nature of the work performed the cost or charges for such work and the person providing the service or performing the work (2) A certification signed by the Authorized Representative as to the current estimated costs of the Project that the materials labor or services represented by the invoice have been satisfactorily purchased performed or received and applied to the project that all funds received to date have been applied toward completing the Project and that under the terms and provisions of the contracts the Local Government is required to make such payments (3) A certification by the engineer responsible for overseeing construction stating that equipment materials labor and services represented by the construction invoices have been satisfactorily purchased or received and applied to the Project in accordance with construction contract documents statmg that payment is m accordance with construction contract provisions stating that construction up to the point of the requisition is m compliance with the contract documents and identifying all additions or deletions to the Project which have altered the Project s performance standards scope or purpose since the issue of the Department construction permit (4) Such other certificates or documents by engineers attorneys accountants contractors or suppliers as may reasonably be required by the Department 10 Additional financing in the amount of $6 798 000 excluding Capitalized Interest, is hereby awarded to the Local Government 11 A combined rate of mterest and Grant Allocation Assessment of 2 56 percent per annum is established for the additional fmancmg amount awarded m this amendment Individually the interest rate is 1 28 percent per annum and the Grant Allocation Assessment rate is 1 28 percent per annum 12 The estunated principal amount of the Loan is hereby revised to $7 800 700 which consists of $7 477 800 authorized for disbursement to the Local Government, a Loan Service Fee of $13 200 to be disbursed directly to the Department. and S309 700 of Capitalized Interest This total consists of the following (a) $768 800 mcludmg $679 800 authorized for disbursement to the Local Government, a Loan Service Fee of $13 200 to be disbursed directly to the Department and $75 800 of Capitalized Interest, at an mterest rate of 2 56 percent per annum and (b) $7 031 900 mcludmg $6 798 000 authorized for disbursement to the Local Government and $233 900 of Capitalized Interest, at a combined rate of interest and Grant Allocation Assessment of 2 56 percent per annum (The interest rate is 1 28 percent per annum and the Grant Allocation Assessment rate is 1 28 percent per annum ) The total amount owed mcludmg the Incremental Loan Service Fee and associated capitalized interest of $141 290 (see following two paragraphs) is $7 941 990 5 13 An Incremental Loan Service Fee in the amount of $132 000 is hereby assessed The fee represents two percent of the portion of the Loan amount authorized by this amendment excluding the associated Loan Repayment Reserve Loan proceeds and Capitalized Interest amounts that is two percent of $6 600 000 An additional Incremental Loan Service Fee amount will be assessed for any additional funding provided by amendment to the Agreement The fee shall be reduced if adjustment of Project costs results m a loan decrease provided that the decrease amendment is executed before the first Semiannual Loan Payment due date Interest shall accrue on the Incremental Loan Service Fee at the combined rate of interest and Grant Allocation Assessment set for the associated Loan increment until the fee is paid Incremental Loan Service Fee interest shall be compounded annually from the effective date of this amendment until six months before the first Semiannual Loan Payment is due at which time it is capitalized (If additional funding is provided interest on the associated service fee shall accrue from the effective date of the amendment providing such funds) The estimated capitalized Incremental Loan Service Fee interest for the fee amount assessed to date is $9 290 14 Section 9 04 REPAYMENT SCHEDULE is deleted in its entirety and replaced as follows The Semiannual Loan Payment shall be computed based upon the principal amount of the Loan plus the Incremental Loan Service Fee and capitalized Incremental Loan Service Fee interest and the principle of level debt service The Department will deduct the Incremental Loan Service Fee and associated interest from the first two payments The Semiannual Loan Payment amount may be adjusted by amendment of this Agreement based upon revised information After the final disbursement of Loan proceeds the Semiannual Loan Payment shall be based upon the actual Project costs and actual dates and amounts of disbursements taking into consideration any previous payments Actual Project costs shall be established after the Department s inspection of the completed Project and associated records Each Semiannual Loan Payment shall be in the amount of $254 937 until the payment amount is adjusted by amendment The interest and Grant Allocation Assessment portions of each Semiannual Loan Payment shall be computed as apphcable on the unpaid balance of the principal amount of the Loan including Capitalized Interest Interest (at the combined rate of Loan interest and Grant Allocation Assessment) also shall be computed on the unpaid balance of the Incremental Loan Service Fee and capitalized Incremental Loan Service Fee interest The interest and Grant Allocation Assessment on the unpaid balance shall be computed as of the due date of the Semiannual Loan Payment Until the Agreement is further amended, each Semiannual Loan Payment will be proportionally applied, after deduction of the Incremental Loan Service Fee is compie e of and repaymen of the amoam s o Nee on each incremental —oan amot nt at tre da e such payment is due Semiannual Loan Payments shall be received by the Department beginning on February 15 2003 and semiannually thereafter on August 15 and February 15 of each year until all amounts due hereunder have been fully paid Funds transfer shall be made by electronic means 15 Section 4 02 PROJECT RELATED COSTS is revised as follows The Local_ Government and the Department acknowledge that the actual cost of the Project has not been determined Project cost adjustments may be made as a result of construction bidding or mutually agreed upon Project changes An additional Loan Repayment Reserve Account deposit will be required for any additional funding provided by amendment to the Agreement Capitalized Interest will be recalculated based on actual dates and amounts of Loan disbursements If the Local Government receives other governmental funding for this Project, the costs funded by such 6 governmental funding will not be financed by this Loan The Department shall establish the final Project costs after its final inspection of the Project records Changes m Project costs may also occur as a result of the Local Government s Pr oject audit or a Department audit Funds disbursed m accordance with this Agreement shall be disbursed in the order m which they have been obhgated without respect to budgetary lme item estimates All disbursements shall be made first from the ongmal Loan amount until that amount has been disbursed The interest rate established for the original Loan amount shall apply to such disbursements for the purpose of determining the associated Capitalized Interest and repayment amounts The combined rate of interest and Grant Allocation Assessment established for any additional increment of Loan funds obligated shall be used to determine the Capitalized Interest and repayment amounts associated with the funds disbursed from that increment Estimated costs are as follows CATEGORY COST($) (1) Administrative Allowance 39 600 (2) Planning Allowance 198 000 (3) Engmeermg Allowance 422 400 (4) Construction and Demolition 5 650 000 (5) Contingencies 565 000 (6) Technical Services During Construction 345 000 (7) Start up Services 40 000 SUBTOTAL 7 260 000 (8) Loan Repayment Reserve (Loan proceeds) 217 800 SUBTOTAL (Disbursable to Local Gov) 7 477 800 (9) Loan Service Fee 13 200 SUBTOTAL (Total Disbursable) 7 491 000 (10) Capitalized Interest 309 700 TOTAL LOAN PRINCIPAL 7 800 700 (11) Incremental Loan Service Fee (including associated capitalized interest) TOTAL AMOUNT OWED 141 290 7 941 990 Loan proceeds for deposit into the Loan Repayment Reserve Account represent three percent of the Loan amount excludmg the Loan Repayment Reserve Loan proceeds and Capitalized Interest amounts that is 3 percent of $7 260 000 is $217 800 The Local Government shall use its own funds to deposit an additional $217 800 into the Loan Repayment Reserve Account The total deposit requirement for the Loan Repayment Reserve is $435 600 The Loan Service Fee represents two percent of the Loan amount authorized prior to July 1 1999 excludmg the Loan Repayment Reserve Loan proceeds Loan Service Fee and Capitalized Interest amounts that is two percent of $660 000 is $13 200 The Incremental Loan Service Fee is not mcluded in this amount because it is not part of the Loan principal The Loan Service Fee plus the Incremental Loan Service Fee excludmg capitalized interest, total $145 200 7 16 Subsections 4 01 (11) and (12) of the Project schedule as amended are deleted and replaced and Subsections (14) (15) and (16) are added as follows (11) The monthly escrow account required under Section 3 01 as amended shall be established and Monthly Loan Deposits shall begm no later than August 15 2002 (12) The initial annual certification required under Subsection 2 01(14) shall be due November 15 2002 Thereafter until the final Semiannual Loan Payment is made the certification shall be submitted each year at the time the annual audit report is submitted (14) Initiation of Protect construction is scheduled for February 15 2000 Completion of Project construction is scheduled for August 15 2002 (15) A total of $435 600 shall be deposited into the Loan Repayment Reserve Account required under Section 3 04 as amended no later than August 15 2002 Loan proceeds m the amount of $217 800 (mcludmg $19 800 disbursed April 14 1998) are provided for this purpose The Local Government shall use its owl finds for depositing the remaining $21 / 800 into the reserve (16) The first Semiannual Loan Payment in the amount of $254 937 shall be due February 15 2003 17 The Local Government agrees to the followmg special conditions (1) Loan proceeds authonzed by this amendment shall not be disbursed until after the Local Government, by resolution m accordance with Ordinance No 99 3 establishes the preliminary assessment roll and makes the final decision to levy the special assessments for repayment of the Loan Certified copies of the adopted resolutions shall be submitted to the Department (2) The Department may unilaterally annul this amendment if the Local Government has not estabhshed the prelunmary assessment roll and made the final decision to levy the special assessments within six months after the effective date of this amendment The Department also may unilaterally revise the Semiannual Loan Payment amount for repayment of the preconstruction Loan If such annulment occurs the Local Government shall immediately begm making Monthly Loan Deposits for repayment of the preconstruction Loan and the first Semiannual Loan Payment shall be due six months after the annulment date If the Department unilaterally annuls this amendment, the Department will provide written notification to the Local Government 18 All other terms and provisions of the Loan Agreement shall remain in effect. REMAINDER OF PAGE INTENTIONALLY LEFT BLANK 8 This Amendment 2 to Loan Agreement CS 12085002P shall be executed m three or more counterparts any of which shall be regarded as an ongmal and all of which constitute but one and the same instrument IN WITNESS WHEREOF the Department has caused this amendment to the Loan Agreement to be executed on its behalf by the Secretary of the Department and the Local Government has caused this amendment to be executed on its behalf by its Authonzed Representative and by its affixed seal The effective date of this amendment shall be as set forth below by the Secretary of the Department for VILLAGE OF KEY BISCAYNE I attest that this amendment complies with Section 2 02 of the original Loan Agreement and as to form and legality Village Attorney for STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION ��'`L'✓�_�--�_. NOV 1.5 1999 Secretary Date 9 SANITARY SEWER COLLECTION SYSTEM STUDY FOR THE VILLAGE OF KEY BISCAYNE October 1997 PREPARED FOR STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION - STATE REVOLVING FUND LOAN AGREEMENT ON BEHALF OF THE r VILLAGE OF KEY BISCAYNE, FLORIDA PREPARED BY <_ CA P Engineering Consultants Inc er 100 Miracle Mile Suite 300 Coral Gables Flonda 33134 (305) 461 5484 Fax (305)461 5494 PROJECT NO 3015-A 1 El F 1 C `I F- I- I Ci 1 f i 1 --1 1-- i 9 r TABLE OF CONTENTS r r L Location Map Table of Contents List of Tables List of Figures List of Maps Executive Summary Chapter 1 Introduction 2 Existing Conditions 3 Future Conditions 4 Development of Alternatives and Description of the Selected Plan 5 Implementation and Conformance LIST OF TABLES 11 11 11 11 1 2 7 15 18 25 Table 1 Village of Key Biscayne Population Estimates and Projections 9 2 Design Population Estimate 15 3 Expected Flow 16 4 Cost Breakdown 25 LIST OF FIGURES Figure 1 STEP System 20 LIST OF MAPS Maps 1 Land Use Legend 3 2 Samtary Sewer Plannmg Map 4 3 Sewer Permit Activity 6 4 Dade County Zoning Codes 8 5 Soil Classifications 10 6 Topographic Reference 11 7 Existing Sewer System 14 8 Proposed Sewer Facilities Attached APPENDIX 1 Existing Water System 2 STEP System Cost 3 Gravity / Forcemam System Cost 4 System Alternative Cost Comparison EXECUTIVE SUMMARY The purpose of this study is to set out a financially feasible Capital Improvement Plan(CIP) for providing a salutary sewer collection system for the Village of Key Biscayne The residents within the Village to be affected are those currently operating septic tanks Upon completion of the construction of the samtary sewer system all areas of the village that previously were not served by the public sewer system would then be able to connect The proposed public sewer system will collect and transport the wastewater to the Virginia Key Wastewater Treatment Plant for treatment and disposal The Central Distract Wastewater Treatment Plant (Virginia Key Treatment Plant) has adequate capacity for the expected flows to be generated by the proposed collection system The area to be serviced is practically built out with only four empty lots available for future growth Most of the area is occupied by single family homes The designated planmng penod for the collection system is 20 years to the year 2017 and the useful life of the sewer extends for an additional 30 years to the year 2047 The Miami Dade Water and Sewer Department (MDWASD) is the utility that will operate and maintain the collection / transmission system will treat the sewerage and will dispose of the effluent The recommendations resulting from this study are consistent with the County s and Village s existing collection system The estimated capital post allowance cost associated with the construction of the collection/ transmission system is $ 7 019 919 The combined number of users to be served by the plannmg area is 706 customers This total translates into $9 943 23 per customer The cost for operation and maintenance of the collection system and for treatment and disposal of the effluent at Virginia Key will be approximately $600 / per year per customer The following actions are recommended 1 Adopt the collection system study recommendations and submit to the FDEP the adopting resolution to accompany the collection system study report already submitted to the FDEP 2 Pursue SRF funding of the collection/ transmission system from FDEP and submit the following ancillary documents capital financing plan with dedicated revenue hearing mformation sewer use ordinance plans and specifications site availabihty certificate notice of intent to permit construction mterlocal agreement with Dade County s Miami Dade Water and Sewer Department which will operate and maintain the collection / transmission system 3 Implement the most cost effective alternative of constructing the collection / transmission system P' 1 INTRODUCTION 1 1 Background The Village of Key Biscayne is in Dade County and is accessible from the north via the Rickenbacker Causeway The planning area is located mainly in the western & central parts of the Village The Master Plan for the Village of Key Biscayne relates the desire that those homes currently utilizing septic tanks go to a public sewer system The master plan was adopted by the Village of Key Biscayne on September 12 1995 and accepted by the Flonda Department of Commumty Affaws on October 20 1995 However as a condition for State acceptance the Master Plan mandates that samtary sewer service will be extended and made available by the year 2006 to all presently unserved areas At the present time all of the homes within the planning area are connected to septic tanks Many of the homes were constructed m the 1960's It is expected that the installation of the public sewer system will increase the value of the properties affected Most of the land use is residential except for some commercial areas along Crandon Blvd as illustrated in MAP 1 ( See Page 2 ) 7 The proposed planning area of the collection system as depicted on MAP 2 (See Page 3) is divided into four zones The boundanes for zone 1 2 and 3 are roughly W Heather Dnve to the North Biscayne Bay to the West Sea View/West Mashta Drive to the South and Crandon Boulevard to the East The last zone Zone 4 hes East of Crandon Boulevard The boundanes for Zone 4 are approximately Crandon Boulevard to the West E Heather Dnve to the South and Ocean Drive to the East 1 2 Scope of Study and Purpose The scope of this collection system study is described below A Inventory existing wastewater facilities (sewer atlas information) service area characteristics (population soil and topography) as well as environmental conditions (e g possible septic tank contamination endangered species etcetera) B Establish design needs for the 20 year planning period (population census information) C Identify and evaluate various wastewater management system alternatives to satisfy the 20 year needs [combined gravity/forcemam sewer system status quo (do nothing option) or Septic Tank Effluent Pumpmg System (STEP)] D Recommend the most cost effective environmentally sound collection system alternative to meet the 20 year needs E Describe in detail the recommended collection system alternatives and their costs 1 d 3 e—It I r 1 t_ LANDUSE LEGEND Single F amily Residential 1' 1 Tw o Family Residenti al Townho use Resid ential Multiple Family Resid enti al Retail Commercial Office commercial Ocean Resort Ho tel Pubhc and Institutional Se mi Public Recre ation and Open Space Public Recr ea tion and Open Space Vaca nt La nd SCALE IN FEET 0 1000 L 1 ,I 0 4' 1tAP SOURCE ROBERT K SWARTHOUT INC aC.A. P. ENGINEERING CQ$SULTANTS. I>ic. WA GE OF KEY BISCAYNE LA ND USB 3 VILLAGE OF KEY BISCAYNE SANITARY SEWER PLANNING MAP JA, C A P. ENGINEERING CONSULTANTS, Inc 4,45 l. �d , f✓i ryej' -. �ti4.a.,%, N\ ` .. ! \ ■ �1 4 1 2 Scope of Study and Purpose (contd ) F Present a schedule for implementing the recommended collection system G Identify any adverse environmental impacts and mitigating project enhancements H Identify a source of financing and estimate the cost per household I Identify the institutional responsibihty for operation and maintenance of the system J Present the study to the public at a public hearing and obtain public in put 1 3 Need Septic tanks can contaminate the groundwater and environment after heavy rams Over saturated poorly drained soils cannot absorb and treat wastewater from septic tanks The soils which make up the existing dram fields due to their low permeability rates are found to have limitations as a source of fill for septic tank absorption fields Normally organisms m the soil would clean up the waste before it reaches groundwater but m sopped soil wastewater will nse to the surface or back up into the household plumbing and emit foul odors Information from the State s Department of Health and Rehabilitative Services (H R S ) provided by the Village shows over 21 permits issued for septic tank and dram field repairs from 1993 1996 The complaint records establish the existence of the following problems improperly functioning septic tanks and improperly functioning dram fields (See MAP 3 on Page 6) bat The septic tank systems may fail or operate inefficiently during heavy rains due to several contnbuting factors First of all the topography of the planning area is fairly flat Secondly as previously mentioned the dram field s soil has poor drainage capacity In addition, the water table is relatively high further impeding the soil s drainage capacity On average only a 2 4 feet difference m elevation exists between the surface and the water table Consequently septic tanks and dram fields may flood and seepage could flow into the environment endangering the health and safety of the residents Thus there is a need for the elimination of the existing septic tank system in order to protect public health by eliminating the nsk of environmental problems In fact the DEP and DERM recommend the use of a sanitary sewer especially on a barrier island There also exists financial reasons which suggest the septic tank systems should be eliminated For example there is a potential loss of real estate property values for those homes/ lots not serviced by a mumcipal sanitary sewer system A lot serviced by a municipal sanitary sewer may provide the opportunity for the construction of a larger home Furthermore HRS regulations are subject to amendment and the change generally becomes more regulatory and more restrictive Finally although the sanitary sewer system has a definite financial impact on residents in the short term the investment should be returned m the very near future VILLAGE OF KEY F3ISCAYNE SEWER PERMIT ACTIVITY kP 3 PERM IT LOCATION 6 /95 335 Atla ntic Road 16/94 50 Wes t Ya shta Drive 2/95 755 Harbor Drive 0/96 820 Harbor Dr ive 14/95 740 Yyrtlewood lane 0/96 725 Gle ar idge Roa d )8/95 773 Ridge wood Roa d 10/95 726 Ridge wood Road L1/95 736 Ridge wood Ro ad 10/95 738 Ridgewood Ro ad L1/93 878 Hampton Lan e )8/95 We st 1[ctntyr e Stre et )8/94 G lenr idge Ro ad L0/95 Warr en Lane L0/95 Woo dcreat Roa d 1/98 525 ltoo dc reat Ro ad 7/98 Gle nr idge Road 8/98 415 Hampton Lane 8/98 212 W IIashta Ro ad 8/98 748 R oo dcre at Roa d 8/98 875 Allenda le Road PLANNING ZONES 73J 820 E1 k ZONE ZONE 2 ZONE 3 ZONE 4 Info rmation pro vided by the Vill age of Key Biscayne an the Florida State Department of Health and Reh abilitative Ser vices (H R S ) /AC A P ENGINEERING CONSULTANTS . Inc 6 2 EXISTING CONDITIONS 2 1 Population and Land Use The population in the planning area is currently estimated to be 1 578 This number was calculated using the 1990 census data from the U S Census Bureau and the population per household from the Village s Master Plan The Village Master Plan assumes that there are 2 3 people/home There are 686 existing residential homes in the planning area The 2 3 persons/home factor from the Village s Master Plan does not take into consideration any difference in population occupancy that may or may not exist between the different types of residential zoning found within the planning area 6 �-J 0.4 r The Village of Key Biscayne is divided into two tracts 46 01 and 46 02 The estimated and projected populations for the Village are shown in Table 1 (See Page 9) The planning area lies pnmanly in tract 46 01 or the westerly tract The 1995 population for tract 46 01 according to Table 1 was 5 856 The population projection for tract 46 01 by year 2015 (two years pnor to our design year of 2017) is 7 855 people Therefore according to Table 1 the population for Tract 46 01 is expected to grow approximately 34% between 1995 and 2015 Assuming the 34% growth rate for the planning area the population of the planning area is expected to be approximately 2115 by the year 2015 This percentage of growth however is not expected because the planning area is practically built out In fact only four empty lots RU 1 residential zoning remain within the planning area. Therefore an increase in population caused by new homes being built will not be of significant impact Very little or no change is expected to occur to the actual homes lying inside the planning area No changes in the Dade County Zoning within the plannmg area are expected at this time A total of 4 empty lots were found to exist within the planning area Changes in the single family units will probably consist of the demohtion of existing homes to construct new ones or remodehng / expansion of the existing facilities Those residential units used for vacation purposes will probably expenence some seasonal population peaks The occupancy of the commercial units will depend on the use and popularity of the particular business ( See MAP 4 on Page 8) 7 VILLAGE OF KEY BISCAYNE DADE COUNTY ZONING CODES IIIIIIIIIIIIIII Pen BU -1 BU -1A BU -2 EU-M GP GU RU -1 RU -2 RU -3M RU -4 RU -4A RU -4L RU -4M 1 I I I I I I I I I I I I I i I I I I 1 1 1 1 1 1 1 1.1 II III 1 11 1 1 I�IIII I N I 1 111111 1 1 1 1 1JII 11 11111111 1 1 1 1 i 1 1 1 1 1 I I II III#III 1 11111 1111111 1 111111 1 1 1#111#1111 1111111111#1111 II 1 1 1 1 1 111 11111 I l l l l l l l l i l I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 I. .I.I #.1.1. 1.1. .1.1 .1 .. 1 # 1 1 1 1 1 ,111 1111 11 1 1 11 1 1 1 1 1 11 11111111 1 1 1 1I I I I.1 1 11 1 1 1#1 1 r C A P ENGINEERING CONSULTANTS. Inc 8 TABLE 1 VILLAGE OF KEY BISCAYNE POPULATION ESTIMATES AND PROJECTIONS 1970 TO 2015 DADE COUNTY BY AREA AND CENSUS TRACT TRACT YEAR 1970 YEAR 1980 YEAR 1990 YEAR 1995 YEAR 2000 YEAR 2005 YEAR 2010 YEAR 2015 46 01 1 222 3 131 5 397 5 856 6 492 7 028 7 643 7 855 46 02 3 397 3 206 3 457 3 477 3 600 3 809 4 061 4148 TOTAL 4 619 6 337 8 854 9 333 10 092 10 837 11 704 12 003 ( INFORMATION TAKEN FROM U S BUREAU OF THE CENSUS CENSUS OF POPULATION FOR 1970 1980 & 1990) (ALL OTHER YEARS FROM METRO DADE COUNTY DEPT OF PLANNING DEVELOPMENT AND REGULATION PLANNING DIVISION 1996) Existing land use m the planning area is dominated by single family residences with some multifamily units and commercial buildings distributed within the area There are approximately 604 existing single family units (RU 1 Dade County Zoning) within the area As noted earlier the four empty lots are zoned as RU 1 The single family homes are found mostly in zones 1 2 and 3 The multifamily units consist of RU 4L (Lmuted Apt. House 23 units / net acre) and RU 2 (Two Family Residential 7 500 sq ft. net) Dade County Zoning A total of 56 RU 4L and 26 RU 2 housing units are found within the planning area The RU 4L units are found in Zone 4 The RU 2 housing units are found in Zones 2 and 3 Finally the commercial buildings are found along the West Side of Crandon Boulevard They correspond to Zones 2 and 4 2 2 Soils. Geology. and Groundwater Soil information has been provided by the U S Department of Agriculture s Soil Conservation Service There are two soil types that occur within the service area The predominant soil type is Urban Land. Urban land is defined as an area where more than 85% of the surface is covered by some man-made structure The other soil type found withm the service area is Canaveral Sand Canaveral Sand is found to have limitations as a source of fill for septic tank absorption fields (See MAP 5 on Page 10) The topography of the service area is nearly level and varies in elevation from 4 ft to 6 ft above mean sea level (See MAP 6 on Page 11) The water table below Key Biscayne is influenced by tidal waters 9 7 VILLAGE OF KEY BISCAYNE SOIL CLASSIFICATIONS r rn 1,4 /a C A P ENGINEERING CONSULTANTS. Inc ralT tam AT warm !GMAaY LIE 6 ILL MOOS Sl IE MC SOILS LEGEND 1\\\\I15 URBAN LAND 39 BEACHES 45 CANAVERAL SAND INFORMATION FROM USDA NATURAL RESOURCES CONSERVATION SERVICE 10 VILLAGE OF KEY BISCAYNE TOPOGRAPHIC REFERENCE rnr /! C A P ENGINEERING CONSULTANTS. Inc 11 2 2 Soils. Geology. and Groundwater (contd from Page 9) 530 11.1.9 7 The average mean high water elevation is 2' above mean sea level The average percolation rate of the soil in this area is only 0 00001 cubic feet per second which is a very poor exfiltration rate There are no pnme aquifer recharge areas within the Village of Key Biscayne The groundwater in the planning area is not used for human consumption The well fields and aquifers recharge areas for the Village s water supply are located on the mainland 2 3 Surface Water Hydrology The existing storm water management systems for the Village are a combination of positive drainage systems exfiltration trenches and drainage wells with emergency outfalls Most of the planning area had no drainage infrastructure in place pnor to 1995 A positive drainage system with drainage wells and emergency outfalls is presently under construction in the planning area. A senes of drainage wells with pollution control strictures have / or will be constructed These wells will be interconnected with the wells typically being 24" in diameter and approximately 150 deep This new system will reduce flooding and improve the quantity and quality of the storm water discharge Finally the planning area is urbanized and does not have any drainage canals lakes or nvers 2 4 Wetlands. Floodplams and Prime and Unique Farm Lands The planning area does not contain any wetlands However significant mangrove wetlands exist north of the north boundary of the Village The wetlands are located in Unincorporated Dade County (DERM Wetland Junsdiction Areas) The only environmentally sensitive area in the Village is the coast line Loggerhead turtles nest on the beaches and manatees are found in the bay According to the Federal Emergency Management Agency Flood Insurance Rate Map (FIRM) the entire planning area is within the 100 Year Floodplam Zone AE The base flood elevations ( for Zone AE ) in the planning area are 9 and 10 feet above sea level This means that any new construction in the planning area must have a finish floor elevation above the base flood elevation The U S Soil Conservation Service Maps show no prime or unique farm lands in the planning area 2 5 Existing Water and Wastewater Systems 2 5 1 Water System The Village of Key Biscayne receives its water from Miami Dade Water & Sewer Department lures The area is served via two main trunk lines a 24 -inch and a 12 mch line The two lines run along Crandon Boulevard in a southerly direction. The 12 PAM 2 5 1 Water System (contd ) homes in the service area are fed by mains and submams feeding off the trunk lines For more detailed information on the facilities a figure showing the existing water lures has been provided (See APPENDIX MAP Al) 2 5 2 Wastewater System Wastewater m the service area is handled by septic tanks and dram fields The area surrounding the service area is served via a public sewer system The public sewer system consists of gravity lines/force mains (See MAP 7 on Page 14) The Central Distract Combmed Wastewater Treatment Plants handled an influent flow of 150 5 million gallons per day (mgd) in 1995 The owners or residents served by septic tanks are held responsible for the maintenance and operation of their respective septic tanks Problems have been found with some of the septic tanks and the dram fields within the plannmg area The existence of the problem is seen m the number of permits pulled to perform work on the septic tank systems In fact records provided from the Village of Key Biscayne show fourteen permits involving dram field repair and two for septic tank repair ( solely between 1993 and 1995) Some of the problems experienced with the septic tanks have been septic tank failure and dram field failure Two possible major problems occurring during heavy rams are effluent percolating to the surface and bad odors due to septic system backups into homes caused by insufficient dram field soil capacity 4 7 Summary- Reasons Why Septic Tanks Should Be Eliminated 7 L plitmt i A Septic tanks may contaminate groundwater and the environment after heavy rams due to the high water table and poor soil percolation B Failure of septic tanks(over 21 permits issued for septic tank and dram field repairs from 1993 1996 C The State approved Master Plan requires the installation of a municipal sanitary sewer system by the year 2006 for those areas serviced by septic tanks D There is a potential for loss of real estate property values for those homes / lots not serviced by a municipal sanitary sewer system E HRS regulations are subject to constant amendment and the change generally becomes more regulatory and more restrictive F A lot serviced by a municipal sanitary sewer may provide the opportunity for the construction of a larger home G Although the sanitary sewer system has a definite financial impact on residents in the short term the investment should be returned m the very near future H Environmental consideration DEP and DERM recommend samtary sewer especially on a barrier island 13 n1Er« i 1 41 ct 4 b re/TY LIMITS AT NORTN BOUNDARY LINE OF BILL BAGOS STATE PARK gg 0 0 1-- 1 I) ( Ir TM ) fun ,'on 3 FUTURE CONDITIONS L 7 31 Design Flows The population of the entire Village for the planning year 2017 is approximately 12 000 The present estimated population for the planning area is 1578 people The planning area build out population projection for the design year year 2017 is 2 398 people This population estimate was made by taking the total number of available units of each type of residential zoning found within the planning area and multiplying it by its respective number of people per household sewer system design figure (this calculation is further explained in TABLE 2 below) The population in the planning area for design purposes is expected to grow approximately 52% between the 1997 and 2017 population estimates The change between the two figures is due to the fact that the sewer design factors are conservative by nature That is these factors need to be conservative (high) in order to take future sewage demands into consideration It is important to remember that the proposed sewer system will meet the year 2017 demands placed on it and is expected to meet the demands placed on it for an additional 30 years ( to the end of the collection system s life span ) The following design population occupancies were assumed 3 5 persons per single family residence and 2 5 persons per multi family unit residence (RU -4L & RU 2) The most conservative of the sewer design factors is that for the RU 1 single family zoning The major difference between the two population totals for 1997 and 2017 is influenced primarily by the dramatic difference between the RU 1 population figures TABLE 2 Dade County Zoning Present Number of Units Present Assumed Occupancy (persons/unit) Estimated Present Population (Persons) Future Number of Units Future Assumed Occupancy (persons/umt) Estimated Future Population (Persons) RU 1 604 2 3 1 389 608 3 5 2 128 RU -4L 56 2 3 129 56 2 5 140 RU 2 26 2 3 60 26 5 0 130 stamated present population = 1,578 3 I Design Flows (contd ) Estimated Future Population = 2,398 The total expected daily flow by planning area build out is 613 806 25 gallons (See TABLE 3 on Page 16) 15 TABLE 3 EXPECTED FLOW Project Name Collection System Study ( for the Village of Key Biscayne ) Project Number 3015 Prebminary Sewage Flow Calculation (Break Down) i Dade County Residential Zoning Respective Number of Units Average Daily Flow Average Flow (GPD) Peak Factor Total Expected Flow (GPD) RU 1 608 units 350 gpd/ unit 212 800 2 5 532 000 RU 4L 56 units 250 gpd/ unit 14 000 2 5 35 000 RU 2 26 umts 500 gpd/ unit 13 000 2 5 32 500 otal Expected Residential Flow Volume(GPD)= 599,500 r� BU -1 Zoning Respective Number of Units Average Daily Flow Average Flow (GPD) Peak Factor Total Expected Flow (GPD) Gas Stations 1 unit 450 gpd/ unit 450 2 5 1 125 Shoppmg Centers 4 125 sq ft 10 gpd/ 100 sq ft 412 5 2 5 1 031 25 Offices 48 600 sq ft 10 gpd/ 100 sq ft 4860 2 5 12 150 otal Expected BU -1 Zonmg Flow Volume(GPD)= 14,306 25 Total Expected Flow Volume for Planning Area(GPD)= 613,806 25 16 axed 3 1 Design Flows (contd from Page 15) 140. r A copy of the expected daily flows and a site plan of the proposed facilities was provided to DERM for their review and comments DERM responded that the Central District Wastewater Treatment Plant has the capacity to handle the calculated flow for this planning study However DERM also related that final certification of adequate/inadequate capacity would be determined by the agency at time of review of presented plans (during the Design Phase) The flow values were calculated assuming the planning area will be completely built out That is the four vacant lots remaining will be developed The flow for RU 1 zomng was amved at using a 3 5 person / household and a 100 gallons/person days production rate The average amount of flow produced by the single family residents is expected to be 532 000 gallons The multifamily residents affected are those residing m RU 4L and RU 2 housing The affected number of umts of each type of zoning are 56 and 26 umts respectively The production rate assumed for the RU 4L residents was 250 g p d / unit The corresponding flow volume turns out to be 35 000 g p d Those residential umts in the RU 2 zomng are expected to contribute at a rate of 500 g p d / unit There contributory flow volume is 32 500 gallons A peak factor of 2 5 was assumed for calculating all residential and business flow volumes The volume produced by the business zomng BU 1 is expected to be 14 306 25 gallons per day 17 4 DEVELOPMENT OF ALTERNATIVES AND DESCRIPTION OF THE SELECTED PLAN 41 General Three alternatives for the collection system have been considered m this study The three alternatives are 1 Status Quo (Septic Tanks To Remain) 2 Septic Tank Effluent Pumping System (STEP) 3 Mixed gravity / force main sewer system The systems were compared and required to meet approval at each of several levels of analysis First the systems should meet requirements of the Village of Key Biscayne Master Plan Secondly the system needs to be technically and physically feasible That is the required land and technology have to be economically available Finally all alternatives passing the first two tests were analyzed using present worth economic analysis The system chosen for implementation is the most cost effective choice The following considerations were taken into account in computing the present worth of alternatives Ala A Planning penod of 20 years B Discount rate of 7 375% C Capital Costs (construction engmeenng legal fiscal and adnumstrative costs) D Operation and Maintenance Costs E Salvage Value based on useful lives of vanous project components ( land permanent conveyance including piping and structures 50 years and equipment including pumps 20 years) F Public acceptance of each of the alternatives 4 2 Status Ouo This alternative includes the continued use of existing septic tanks and dram fields The continued use of the septic tank system would create no new costs at the present time to the Village However additional costs would be incurred upon failure of the existing septic tank systems 18 4 2 Status Ouo (contd ) Status Ouo Analysis The existing system has proven to have occasional problems Furthermore the system is an aging one Therefore it is a logical assumption that the frequency of septic tank / dram field failures thus the need for repairs will increase Continuing costs associated with the status quo option mclude (1) Cleaning of the septic tank (2) Replacing / maintaining dram field and (3) Replacing detenorated septic tanks Furthermore any and all of these costs would fall directly on the property owner Besides the continued costs previously mentioned the problem of effluent percolating to the surface and the bad odor associated with it during heavy ram falls would not be eliminated Finally and most important of all the do nothing alternative will not satisfy the requirements of the Village s Master Plan As a result the status quo option is not considered as a viable alternative r n r 4 3 Septic Tank Effluent Pumping System (STEP) This is a pressure sewer system In this alternative a dual submersible pump system would be installed inside the septic tank The septic tank would continue to be in use but the dram field would be abandoned As flow is received in the septic tank the solids settle at the bottom and would be removed penodically The flowable effluent from the septic tank instead of going to the dram field would be pumped by the submersible pump to the low pressure small diameter service connection lines which would then feed into larger diameter pressure mains in the street The pressure main in turn would convey the flow to the main pump stations from where the flow is pumped to the Virginia Key Wastewater Treatment Plant (See FIGURE 1 on Page 20) Septic Tank Effluent Pumping System (STEP) Analysis The STEP system alternative would eliminate the problem of effluent percolating to the surface and the associated bad odor which may occur dunng heavy ram falls However some septic tanks would have to be replaced due to their detenorated condition or to accommodate the pump system In addition this option would incur costs to the residents of maintaining / cleaning of septic tanks and pumps installation of the dual on site pump system installation of on -site electrical system installation of lateral (force main) and connection fee The average expected life of a typical single step pump is from 18 months to 3 years The expected life of a dual pump set up is approximately 5 years In the dual pump set-up the pumps work in an alternating basis This set up allows time for replacement in the event that one pump fails since theoretically both pumps will not fail at the same time As a result, we considered the dual pump set up in our cost analysis ( See APPENDIX) This option has a lower initial cost than the gravity / forcemam alternative However analysis shows that this advantage is lost when considering the 20 year design penod (See APPENDIX) This is the case since the pumps would need to be replaced approximately 3 times dunng the design span ( up through year 2017 ) 19 1 1 1 1 V-1 I- 1 [ J 9 1 i 9 a i r k 1 1 FIGURE 1 0 0 J Li - Z L FIN GRADE POWER STAND---__. _ PATIO STONE el_ L L —III,{ s 1_,��� ���, 11 � flI=u1=111 ;I -ril 111- I CLEAN OUT PVC CONDUIT T0_, TANK POWER STAND PRESSURE SEWER PIPE SUMP PUMP CHAMBER �____ ._ PUMP EXIST SEPTIC TANK 0 1 M I i in STEP SYSTEM N TS 20 4 3 Septic Tank Effluent Pumping System (STEP) Analysis (contd from Page 19) The Miami Dade Water and Sewer Department is not organized for managing a system with wet wells and force mains in easements on private property The Village would be responsible for maintenance of the system Advantages and Disadvantages of STEP System Advantages 1 Low Construction Costs 2 No infiltration/ exfiltration 3 STEP systems reduce gnt grease and solids present in wastewater flow 4 Shallow sewer depths 5 Cleanouts used instead of manholes Disadvantages 1 Multiple pumping units required 2 Relatively high operation and maintenance requirements 3 STEP systems require periodic cleanmg of septic tanks and disposal of septage 4 Individual services susceptible to power/ pump failures (unless overflow storage is provided) 5 Potential odor/ corrosion problems Cost Summary Capital costs (fundable with SRF momes) = $2 853 620 Present Worth ( SRF and customer charges over 20 year design penod ) = $13 829 970 L 21 4 4 Gravity Sewer System A gravity sewer system consists of a network of pipe lines manholes laterals and lift / pump stations with force maws The house laterals feed the gravity sewer lines Pipe flow criteria will be taken into account at the time of design The pipe lines are designed such that their slope maintains a self cleansing wastewater velocity of at least 2 feet per second Gravity hnes force effluent to travel along pipes / manholes until reaching the deepest manhole for a particular system Here the gravity system terminates and the force (pressure) system begins The deepest manhole corresponds to the wet well of a pump station A pump forces the effluent from the structure into a force (pressure main) which takes the effluent on its way to the treatment plant Monetary Factors MTH tusrt lzmu Although the initial capital costs are higher for this alternative than for the other two this alternative was chosen as the best of the three The reasons for choosing this alternative are several First this alternative is the type of public sewer system bemg utilized throughout Dade County As a result an agency to operate and mamtarn this type of system currently exists the Miami Dade Water and Sewer Department This would not leave the maintenance of the system up to the 706 individual customers therefore making the system more reliable This option will prove to be more maintenance free than the S 1'l:P system alternative Therefore the maintenance costs associated with this alternative will be lower Furthermore this system while representing a higher initial system cost corresponds to a lower cost up front for property owners The costs to be paid directly by the property owners for the gravity / force main system is approximately $4 600 while the costs for the STEP system is approximately $5 100 In addition, this alternative conforms to the Village s Master Plan that the entire Village have a public sewer system by the year 2006 Finally this would eliminate the threat of the possible health / contamination problems associated with septic tanks Non monetary Factors Both systems will utilize dual pumps for reliability However the pumps in the gravity sewer system will be maintained by MDWASD and the STEP system pumps will be maintained by the individual home owners Secondly implementing the gravity sewer system will be easier because the MDWASD operates and maintains this type of system Thirdly the equipment would be compatible with the equipment currently bemg used m the Village However the STEP System would will be easier to construct because of the high ground water table Finally both systems will benefit the environment by eliminating the existing drainfields The STEP System will have no infiltration/ exfiltration while the gravity sewer may mtercept and dram groundwater if not properly constructed 22 Proposed Facilities The proposed sewer facility for the Village of Key Biscayne planning area is shown m the inside cover (See ATTACHED 24 X 36" PLAN) The project will consist of the following Tic Pea A 46 000 L F of 8 D I P forcemam gravity sewer and appurtenances B 4 Lift Stations C 19 650 L F of 6" D I P forcemam and service laterals D 5000 L F of 8" 12" and 24' DIP force main E Abandoning 706 septic tanks and F Repairs to streets drive ways and landscaping Cost to Construct Facilities The details of the gravity / force main system s cost is presented in the APPENDIX The following tabulation shows the construction related costs for Items A through F from above Construction (mcludmg contingency) Engineenng & Inspection PRESENT WORTH (For SRF monies and customer charges over 20 years ) 4 5 Cost Reduction Considerations _$ 6 215 000 _$ 767 400 4 12,584,96576 The proposed collection system is expensive The following methods were looked at to lower the project cost. A Use Low Cost Materials The use of alternative matenals to minimize the construction cost was considered The system will be donated to the Miami Dade Water and Sewer Department. The type of matenal to be used in the project will be determined during the design phase Therefore for planning purposes the materials selected were consistent with those required by the MDWASD on current projects withm the Village of Key Biscayne The material bemg used is polywrapped D I P or C 900 pipe 23 B Implement other Low Cost Alternatives The Step System while having a lower capital cost was found to be unacceptable The reasons for this system proving unacceptable were stated in Section 4 3 Other low cost alternatives such as a grmder pump would be unacceptable for similar reasons Therefore these other low cost alternatives were not explored in the cost effective anlaysis by the Village C Reduce scope of project The scope of the project can be reduced and the construction phased to reduce the initial cost The ultimate cost however will be more because the entire area needs to be sewered The contract administration and construction cost will increase if the work is phased Besides the existing system needs replacement due to its deteriorated condition D Other Sources of Fmancmg Alternate sources of financing the project are available but the interest rates are greater than that available from the State of Honda Revolving Fund Program (SRF) administered by the Honda Department of Environmental Protection (I-DEP) A loan apphcation has been made and the funds are immediately available 4 6 Environmental Impacts of Proposed Facilities Long Term Impacts A No significant adverse effect on either air or water is anticipated B No wildlife habitat will be affected ( the planning area is Urbanized ) C No effect on threatened or endangered animal or plant species D No archaeological or histonc sites are found in the planning area Short term Impacts r L r^ There will be some short term impacts dunng construction. For example these impacts will include an increase in noise levels and an increase m the amount of airborne particulate matter (dust etc) Furthermore there will be some interference with motor vehicle traffic due to lanes being closed dunng construction detours or traffic control around construction areas and movement of construction vehicles and equipment Erosion and sedimentation may occur during construction grading due to rainfall on the site Control measures will be implemented throughout the construction phase to attempt to alleviate the situation as much as possible For instance effective maintenance of traffic plans will be evaluated and implemented and the construction areas will be watered if dust is excessive or at an unacceptable level The long term effects of the project however will prove beneficial to 24 the Village residents Specifically the benefits can be seen m the ehmmation of contamination problems which can result from detenorated septic tank systems atm 25 5 IMPLEMENTATION AND CONFORMANCE 5 1 Implementation 1 Financial Planning The Department s State Revolving Fund (SRF) loan is expected to be the financing source for the project A capital financing plan (CFP) will be prepared and the public will be informed during a dedicated revenue hearing of the financial impact of the project on the users of the sewer system The dedicated revenue is to be repaid by a special assessment The total cost associated with the construction of the collection / transmission system is estimated to be $7 019 919 or $9 943 23 per customer Table 4 below shows the break down for the project costs TABLE 4 ITEMS TOTAL PRECONSTRUCTION PROJECT COSTS Construction demolition equipment and materials $5 650 000 Contingencies $565 000 Technical services during construction $345 000 Startup services $40 000 Loan repayment reserve (incremental) $198 000 Loan Service Fee (incremental) $132 000 Capitalized Interest (incremental) $89 919 TOTAL POST ALLOWANCE PROJECT COSTS $7,019,919 1 Financial Planning (contd ) Abandoning the septic tanks and installing house service laterals is equivalent to an average of $1950 per residential customer The permit fees correspond to $50 per customer The MDWASD one tune connection fee corresponds to $2 000 per residential customer These three fees amount to $4000 and compromise the up front costs to a residential customer Based on the SRF loan amount of $7 019 919 for the collection/transmission system ( with an interest rate of 2 56%) the annual payment due would be 26 5 1 Implementation (contd ) 1 Financial Planning (cont d) $452 784 78(with interest) or an average of $641 34 per customer per year The annual operation and maintenance cost for the collection / transmission system is equivalent to an average cost of $600 per residential customer This cost will be reflected in the customers water & sewer bill 2 Public Participation An advertised public hearing will be held to obtain comments from the public A thorough explanation of the proposed project costs for the collection / transmission system and for the homeowner will be provided The timing of construction and the benefits of the proposed system will be explained Public input is expected and will be considered at the Village Meeting before the collection system study receives final approval rim 3 Governmental Review Copies of the study were sent to the FDEP Office of the Governor (State Cleannghouse) and the Regional Planning Commission for their review In order to qualify for a subsidized SRF loan the FDEP must be satisfied with the plan the Village is proposing to solve its sewage collection problem Upon approval of the collection system recommendations by the Village the adopting resolution must be sent to the FDEP 4 Implementation Responsibility The Mianu Dade Water and Sewer Department will have the responsibihty of operating and maintaining the system Furthermore MDWASD will receive and treat the sewage and dispose of the effluent r L 27 7 5 1 Implementation (contd ) 5 Implementation Schedule Sewer Use Ordinance Completed Apnl 1997 Dispute Resolution Process Completed April 1997 Capital Fmancing Plan July 1997 Public Hearing July 1997 Collection System Study July 1997 Interlocal Agreement Oct 1997 Environmental Information Document Oct 1997 Authonzation For Design Dec 1997 Design of All Project Aug 1998 Certification of Site Availability Sep 1998 Authorization to Incur Post Allowance of Project Cost Oct 1998 Advertise For Construction Bids Dec 1998 Start Construction Feb 1999 Complete Construction Feb 2000 5 2 Conformance 1 The engineenng aspects of the selected alternative are in conformance with applicable provisions of Honda Administrative Code Chapter 17 503 2 The recommended actions are consistent with the comprehensive plan of the Village of Key Biscayne and Dade County AWN it f 79 28 APPENDIX r 9 3 LI L _4 Bell. OPP I �Yrit) .a ( ) — PEE, r - 1 0 0 40 4 -C A P ENGINEERING USING WATER slsrEM - 100 MIRACLE MILE SUITE 300 CVILLAGE OF KEY BISCAYNE Nava 31VLs soave iile jo 3Nn AHVUNfloe NINON 1V SLIwn Allo-1 uu ooc (++ae) NM (1n X I) 1 STEP SYSTEM COST ESTIMATE Zone1 8725 --15 Zone2 11115 LF Zone 3 16902 LF Zone 4 7285 LF Late Is 6 DIP at an ave age of 25 of p pe per un F RU -1 608 UNITS RU -4L 56 UNITS RU -2 26 UNITS BU -1 16 UNITS Late als 6 DIP 706 Total Units In summary 45000 LF OF4 DIP (LOW PRESSURE FORCEMAIN) 52950 LF OF15 PVC(LATERAL) OF WHICH 17650 LF ARE FUNDABLE BY S R F 2000 LF OF 4 DIP (FORCEMAIN) 1000 LF OF 6 DIP (FORCEMAIN) 1000 LF 8 DIP (FORCEMAIN) 3000 LF 12 DIP (FORCEMAIN) BREAKDOWN PIPE DESCRIP OTT PRICE PER UNIT UNIT/INSTALL TOTAL 15 PVC 17650 $ 300 $ 750 $ 13237500 4 DIP 47000 $ 1350 $ 2450 $1 151 500 00 6 DIP 1000 $ 1969 $ 3000 $ 3000000 8 DIP 1000 $ 22.75 $ 44100 $ 4000000 12 DIP 3000 $ 3693 $ 55.00 $ 16500000 TOTAL $1518,87500 PUMP STATIONS DESCRIP SUBMIRSIBLE PUMP PAVEMENT REST DESCRIP ASPHALTIC CONCRETE OOSTFOR RESIDENTS PIPE PUMP DESCRIP 1 5° P V C LATERAL DESCRIP 0 TO 5 YEARS DOUBLE LOW PRESSURE PUMP OTT PRICE PER UNIT TOTAL 4 $ 200 000 00 $ 800 000 00 TOTAL S 80000000 sq ft sq yd PRICE PER UNIT TOTAL 326900 'x'122 22 $ 758 $ 275 32244 TOTAL 3 27532244 OTT 35300 LF $ OTT 706 SUB -TOTAL $ 2594 197 44 10 % contingency $259 419 74 TOTAL (FUNDABLE BY SRF) $ 2,853,61719 PRICE PER UNIT UNIT/INSTALL 3.00 $ 750 $ 264 750 00 PRICE PER UNIT UNIT/INSTALL $ 800 00 $ 1 600 00 VILLAGE OF KEY BISCAYNE $112960000 MSC FEES SEWER CONNECTION PERMIT FEE 706 $ 5000 $ 3530000 CONNECTION FEE FOR MDWASD 706 $ 200000 $1 412 000 00 ANNUAL OPER & MAINT FEE(WASA) 706 $ 60000 $ 423 600 00 ANNUALOPER &MAINT FEE(STEP) 706 $ 17500 $ 123 550 00 PUMP OUT & ABANDONMENT 706 $ 30000 $ 211 800 00 SUB -TOTAL COST FOR RESIDENTS $ 3 600 600 00 COST PER CUSTOMER S 5 100 00 NOTE Costs to owners does of include abo donment of tank nor replacement of tank ( due to deter orated oondrt on or inadequacy fo fu cboning & pl cement of pumps) if applicable VILLAGE OF KEY BISCAYNE Lw 91,40 F Mt. Sanitary Sewer Cost Estimate Zone 1 8725 —LF 30 MANHOLES Zone 2 11115 LF 30 MANHOLES Zone 3 16902 LF 47 MANHOLES Zone 4 7285 LF 25 MANHOLES Late al 6 DIP at an a erage of 25 otp pe per unit RU -1 608 UNITS RU -4L 56 UNITS RU -2 26 UNITS BU -1 16 UNITS Late als 6 DIP 706 Total Units In summary 45000 LF OF 8 DIP (GRAVITY SEWER) 52950 LF OF 6 DIP (LATERAL) OF WHICH 17 650 LF ARE FUNDABLE BY S R F 132 MANHOLES 2000 LF & DIP (FORCEMAIM 1000 LF 8 DIP (FORCEMAIN) 1000 LF 12 DIP (FORCEMAIN) 3000 LF 24 DIP (FORCEMAIM BREAKDOWN MANHOLES PIPE DEPTH QTY PRICE PER UNIT UNIT/INSTALL TOTAL 6 OR LESS 20 $ 92500 $ 2300 00 $ 46000 00 6 8 40 $ 1,27500 $ 3 200 00 S 128 000 00 8 OR GREATER 72 $ 1 650 00 $ 4100.00 8 295,20000 TOTAL $ 46920000 DESCRIP OTT PRICE PER UNIT UNIT/INSTALL TOTAL 6° DIP 19650 $ 1969 $ 4430 $ 870 49500 8 DIP 46000 $ 2275 $ 6000 5276000000 12 DIP 1000 $ 3693 $ 8500 $ 86 000 00 24 DIP 3000 $ 54 59 $ 130 00 S 390 000 00 TOTAL $4 105 495 00 PUMP STATIONS DESCRIP SUBMIRSIBLE PUMP PAVEMENT REST OTT PRICE PER UNIT TOTAL 4 $ 200 000 00 S 800 000 00 TOTAL $ 80000000 DESCRIP sq ft sq yd PRICE PER UNIT TOTAL ASPHALTIC CONCRETE 326900 A6.S9222 $ 758 $ 275 322.44 OVERALL TOTAL 10 % CONTINGENCY TOTAL $ 275 322.44 55650 017 44 $565,001 74 TOTAL (FUNDABLE BY SRF) $ 6,215 01919 7 COST FOR RESIDENTS PIPE DESCRIP OTY PRICE PER UNIT UNIT/INSTALL 6' DIP LATERAL 35300 LF $ 1969 $ 3000 $1 059 000 00 MSC FEES SEWER CONNECTION PERMIT FEE 706 $ 5000 $ 3530000 CONNECTION FEE FOR MDWASD 706 $ 2 000 00 $1 412 00000 ABANDOMENT FEE 706 $ 450 00 $ 317 700 00 ANNUAL OPER & MAIM FEE 706 $ 600 00 $ 423 600 00 SUB -TOTAL COST FOR RESIDENTS $324760000 GRAND TOTAL $946261919 System Cost Comparison Total Number of Customers to be Served = 706 Planning Period Considered for Analysis = 20 years Interest Rate Used for Analysis = 7 375% 1 t STEP SYSTEM Present Worth For System (for monies fundable by SRF monies) PW Present Worth For System (for 20 year design period) ITEMS TO CONSIDER _ $ 2 853 617 19 Present Costs Costs from above for system = $ 2 853 617 19 Costs for laterals = $ 264 750 Costs for initial dual pump system sewer connection permit fee connection fee for MDWASD and pump out & abandonment = $ 2 788 700 TOTAL = $ 5, 907, 06719 Annual Costs Annual Operation & Maintenance for System(WASA) = $ 423, 600 / year Annual Operation & Maintenance for System(STEP) _ $ 123, 550 / year Future Costs Double Step Pump (706 umts) at year 5 = $ 1, 412, 000 Double Step Pump (706 units) at year 10 = $ 1, 694, 400 Double Step Pump (706 units) at year 15 = $ 2,118, 000 Salvage Value (straight line depreciation) was calculated for all components of the project which have a useful life greater than the analysis penod ( life span > 20 years ) Costs Pipe ( 50 year useful life) = $1 783 625 POT Therefore S V =1,783,625 20 [ (1,783,625 0) / 50 ] = $ 1, 070,175 Taking into account present costs annuanl costs and the future costs we get the following equation for our present worth analysis P W = PRESENT COSTS + ANNUAL COSTS + FUTURE COSTS PW = $5 907 067 19 $547150[((l+i) MOO +i) )]+ $1412000(1+i)5 + $1694400(1+i)i0 + $2118000(1+1)t5+$1070175(1+i)20 P W $5 907 067 19 $5 631 339 85 $989 279 05 $831 733 46 $728 414 03 + $257 864 33 = $ 13, 829, 969.25 piss GRAVITY / FORCEMAIN ALTERNATIVE Present Worth For System (fundable by SRF monies) PW Present Worth For System ( over 20 year design period ITEMS TO CONSIDER Present Costs =$6 215000 Costs from above for system = $ 6 215 000 Costs for laterals = $ 1 059 000 Costs for sewer connection pernut fee connection fee for MDWASD and septic tank pump out and abandonment fee = $ 1 765 000 TOTAL = $ 9, 039, 000 Annual Costs Annual Operation and Maintenance Fee = $ 423, 600 / year Future Costs The salvage value for this alternative is as follows Cost Pipe = $ 5 164 495 Manholes = $ 469 200 Total Cost = $ 5 633 695 Therfore S V =$5,633, 695 20 [ ( $5, 633, 695 0) / 50 ] = $ 3, 380, 217 P W = PRESENT COSTS + ANNUAL COSTS + FUTURE COSTS PW = $9 039 000 $423600[((1+i) 1)/(i(1+i) )]+ $3 380 217(1+1)20 P W = $9 039 000 $4 359 746 92 + $814 481 16 = $12, 584, 265 76 The present worth analysis provides insight into the present costs associated with each system and how the 20 year costs compare between alternatives The costs of the STEP system is less than that of the gravity / forcemain alternative when considenng the costs fundable by SRF monies The costs for the step system is approximately $ 2 853 620 while the gravity / forcemain will cost approximately $ 6 215 000 However when considenng all of the associated costs of each system over the 20 year design penod, the STEP system turns out to be more expensive than the gravity / forcemain alternative The step system will now cost approximately $ 13 829 970 and the gravity / forcemain $ 12 584 270 As a result the gravity / forcemain is the best alternative considenng the 20 year design period pma