HomeMy Public PortalAbout333028etropolitan St. Louis Sewer District 2350 Market Street St. Louis, MO 63103-2555 (314) 768-6200 December 15, 2008 Mr. Brad Gianotti Regulatory Compliance Coordinator BaySaver Technologies, Inc. 1302 Rising Ridge Road Mount Airy, MD 21771 RE: Baysaver Technologies BaySeparator: St. Louis MSD Submission Redevelopment Use Level (RUL) Approval within District Dear Sir: The Metropolitan St. Louis Sewer District (MSD) has reviewed your application regarding the BaySeparator for use as a Best Management Practice for stormwater management. MSD is pleased to provide Redevelopment Use Level (RUL) approval for use of the BaySeparator as a stand-alone water quality BMP, subject to the following provisions. ® The BaySeparator is only approved for use on redevelopment sites less than 5 acres. This approval is based on compliance with requirements listed in MSD's Proprietary Water Quality Products and the MSD's Stormwater Management Program (Jan. 2008). The BaySeparator must be sized to capture all floatable trash and free oil, and remove 80% of total suspended solids for the OK-1 10 particle size distribution at the site water quality flow -rate (WQr). Procedures for calculating WQt are provided in Appendix D.10 of the Maryland Stormwater Design Manual (2000). Table 1 provides a list of approved models and their respective instantaneous peak treatment WQ,-. Table : BaySeparator Approved Models and Peak W System Model Primary & Secondary Manhole Max Treatment Flow (cfs) Depth (feet) Diameter (feet) 1/4 K 6 4 0.24 1K 8 4 0.3 3K 8 5 1.0 5K 8 6 2.0 1 OK 8 10 3.7 The primary and secondary manhole, as well as the Baysaver unit, should be configured in an off-line layout. In most cases the BMP will be installed without the need to store the water quality volume (WQ,;) upstream of the unit. All devices shall provide a minimum sediment storage capacity of 10 ft3. " Confined space entry shall not be a requirement for routine maintenance. No special tools or attachments should be required to provide routine maintenance with a vacuum pumping truck. " All proprietary Lids and covers should be captive components. The minimum size access hole is 30 inches in diameter. " Project specific design calculations and maintenance plans furnished by BaySaver must be included within the project's "Stormwater Management Facilities Report" prepared by the consulting engineer. The devices maintenance plan shall be consistent with the plans presented in the 11/24/08 revised BaySaver Technical and Design Manual. " The initial installation of the BaySeparator in the MSD shall include the following. 1) A manufacturer's or vendor's representative must be onsite during the proprietary BMP installation to ensure the product's installation requirements are met. 2) Shop drawings indicating elevations of flowlines, weirs, pipe inverts, etc. will be required prior to installation. 3) The manufacturer or vendor must arrange for an as -built survey of the proprietary BMP to be performed by a Missouri -registered Professional Land Surveyor once the device has been installed, and prior to any testing or monitoring. 4) The manufacturer or vendor must perform quarterly inspections of the proprietary BMP during its' first year of operation, which will include visual inspections and quantitative analysis of the service's sediment removal efficiency, especially as compared to its design efficiency. MSD requests to be invited to these inspections to further enhance familiarity and understanding of the device. 5) Formal reports shall be submitted to MSD, including as-builts and at each quarterly inspection. The reports shall include summaries, quantitative analysis mentioned in item 4, photographs of the structure, inlet, internal conditions of the structure, the filters, and outfall conditions, etc. The reports shall also evaluate the performance of the owner's adherence to the approved maintenance program, and offer suggestions for any areas of improvement. The BaySeparator is not approved for general or highway use at this time. MSD may reconsider highway use level designation in the future, pending the successful installation and operation of the BaySeparator at other sites within the MSD. MSD reserves the ability to withdraw or modify this approval based on subsequent information, including information indicating that this BMP does not satisfy MSD rules, requirements, or construction specifications. Sincerely, Michael T. Buechter, P.E. Principal Engineer (BMP Committee Chairman) Engineering/Design Metropolitan St. Louis Sewer District