HomeMy Public PortalAbout382431A
4-#3 REBARS
4-#3 REBARS
3/4" DIA. HOLE 22" 3/4" DIA. HOLE
3-1/2
NOTES:
3-1/2"
5 1/2"
46"
A
PLAN
5"r•
-#3 REBARS
46"
5-1 /2"
II
II\III
- H
II I I i- lI
4-#3 REBARS
9, 0"
8"
ELEVATION
4-1 /2"
48"
3-#3 REBARS
...
5-1/4"
8"
13-1/4"
6"
36"
7"
SECTION A —A
NOTE 1
NOTE 2
1) SET TWO (2) STANDARD INLET STONES IN 3/4" MORTAR BED AND DOWEL WITH 5/8" DIA. 1'-0" LONG PINS
AND GROUT.
2) RAISE TO FINAL GRADE WITH COURSES OF BRICK AND SET THE UNIT TO BASE WITH 3/4" MORTAR BED.
3) THIS UNIT IS TO BE USED WITH POURED -IN -PLACE CONCRETE BASE.
4) 5000 P.S.I. CONCRETE REQUIRED.
5) 1 INCH CLEARANCE, ALL REINFORCEMENT.
PRECAST CONCRETE
UNIT "A" FOR STREET
DOUBLE INLET
METROPOLITAN ST. LOUIS SEWER DISTRICT
Standard Details of Sewer Construction
Dr. RGW/SAM
Ch. J.C.K.
2009
SHEET 42