HomeMy Public PortalAbout382460F► A
APPROVED REMOVABLE CAP.
LOW SLUMP
CLASS "A" CONC.
SEE PLANS.
NOTE:
MIN. 2'
LONG JOINT
CAST IRON FRAME & COVER.
NEENAH FOUNDRY R-1975
OR APPROVED EQUAL.
8"(TYP.)
6"(TYP.)
6"(TYP.)
MIN. 6" DIA.
4 44
4 °
6"
4.
P.V.C. PIPE.
4 4
.4
°
4
COMPACTED SELECTED
EARTH BACKFILL.
4
CLASS "A" CONCRETE. °4
°
a4 4 A °
'4
°
4' MINIMUM
CONCRETE ENCASEMENT.
DO NOT USE WYES
y A
4
) ▪ MIN. 6" DIA.
is P.V.C. PIPE.
a
4
4
4
TRENCH
WIDTH.
4
4
o
.a
4
\X/
1
°
PLAN SECTION A —A
SAMPLING TEE DETAIL
SAMPLING TEE
METROPOLITAN ST. LOUIS SEWER DISTRICT
Standard Details of Sewer Construction
Dr. S.A.M.
Ch. P.W.S.
2009
SHEET 70