HomeMy Public PortalAbout382472LINE OF ACTUAL EXCAVATION. OUTSIDE OF PIPE BELL. 6" MINIMUM 7 , OUTSIDE OF PIPE BARREL.'r, SUBGRADE REPLACED CAREFULLY COMPACTED (SEE NOTE 2) f PAYLINE WIDTH "W" MSD SEE TABLE NO.1 STANDARD CONSTRUCTION SPECIFICATIONS. COMPACTED CRUSHED LIME- STONE AND SCREENINGS. PAYLINE FOR CLASS "C" EXCAVATION. 6" MINIMUM 2 . LINE 117 • 4" MINIMUM yiki 12" OR GREATER / % GEO FABRIC TYPE 3 PROVIDE BELL HOLES AT EACH JOINT. LINE OF ACTUAL EXCAVATION. BLOCKING OF PIPE NOT PERMITTED. PAYLINE FOR CLASS "C" EXCAVATION. NOTES: 1) CHECK GRADE OF PIPE AFTER COMPACTION TO INSURE THE DESIRED FLOWLINE HAS NOT CHANGED. 2) SUBGRADE REPLACEMENT SHALL BE COMPACTED WITH HAND OPERATED VIBRATORY COMPACTORS OR SIMILAR EQUIPMENT. SPECIAL PIPE BEDDING DETAIL FOR UNSUITABLE SUBGRADE REPLACEMENT 12" DEPTH OR MORE F____ METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. S.A.M. Ch. P.W.S. 2009 SHEET 7