HomeMy Public PortalAbout382550M.S.D. STANDARD MANHOLE FRAME AND COVER. SURFACE ELEVATION. * 118" MAX. * ADJUST TO GRADE WITH APPROVED GRADE RING. IF THE TOTAL HEIGHT OF ADJUSTMENT IS 6 INCHES OR MORE, A MAXIMUM OF TWO (2) GRADE RINGS IS ALLOWED. METAL GRADE RINGS ARE NOT ALLOWED ON NEW CONSTRUCTION. PLAN NOTES: ELEVATION 1/4" STEEL LIFTING HOOK. 2-#3 REBAR CONT. (9 INCHES LAP AND TIED) EXISTING STRUCTURE IN PAVEMENT MAY BE ADJUSTED WITH ONE APPROVED METAL GRADE RING. 4" MAXIMUM. PRECAST TOP TRANSITION SECTION. RISER SECTION "B" 1/4" STEEL LIFTING HOOK. 1- -•-2" CLEARANCE GRADE RING SECTION 1) IF BRICK IS USED DO NOT PLASTER INSIDE OF MANHOLE. 2) IF MANHOLE IS BURIED MORE THAN 18 INCHES, A RISER SECTION WILL HAVE TO BE ADDED. 3) DIMENSION "A" STOCK GRADE RING HEIGHT OPTIONS. (3 INCHES MINIMUM TO 11 INCHES MAXIMUM.) 4) DIMENSION "B" STOCK RISER SECTION HEIGHT OPTIONS. (12 INCH, 24 INCH, 36 INCH AND 48 INCH) ADJUST TO GRADE F____ METROPOLITAN ST. LOUIS SEWER DISTRICT Standard Details of Sewer Construction Dr. S.A.M. Ch. P.W.S. 2009 SHEET 23