HomeMy Public PortalAbout10-25-1999 Letter from CAP Engiineering Consultants re Final Payment.tif- C.A.P. Engineering Consultants, Inc. MEMORANDUM TO: C. Samuel Kissinger - Village Manager, Village of Key Biscayne FROM: Andrew Pierce, P.E.»Project Manager DATE: October 25, 1999 RE: West Mashta Drive Bridge Final Payment - Project Close Out C.A.P. Project No. 3011B Please find enclosed the following: 1. Water and sewer as-builts approved by Miami -Dade Water and Sewer Department (MDWASD) and job completion memorandums. 2. Letter of release from the Florida Department of Health (HRS). The remaining punch list items for the above mentioned project have been completed. Kindly prepare the final payment (joint checks) as per the payment request by Bunnell Foundation on 8/16/99. If you have any questions, please contact me at your earliest convenience. F \DATACL\CAP\3011 \3011B wMashta Br Final Pmt wpd r Milt, 1 ',1H I ';n0 • C/Jr,1I Cables, Floric1 33134 • Hcix (305)101-51,M NEE a ,.F-orunoRTian, int. Village of Key Biscayne Office of the Village Manager 85 West McIntyre Street Key Biscayne, Florida 33149 Attn: Mr. C. Samuel Kissinger Village Manager (305) 365-5507 Office (305) 365-8936 Fax phone (305) 594-9900 August 16, 1999 Re West Mashta Drive Bridge Project No.: 3011-B Subj.: Final Requisition and Payment Request for Joint Checks The placement of the four aluminum flag poles on the West Mashta Bridge has been completed, and constitutes the balance of the work to be finished on the project. All other punch list items have been completed as well Attached you will find a copy of the final requisition on this project, identified as Requisition # I I, in a final amount $ 59,360.94. Bunnell Foundation, Inc. Is requesting that the Village of Key Biscayne issue joint checks on the final payments on this Contract. The following is a list of the requested joint checks for vendors and subcontractors. Of course, each vendor or subcontractor will furnish the Village with a Final Release of Lien upon payment of these final amounts. 1 Total Amount of Requisition # 11 $' 59,360.94 2 Cone / Bunnell Foundation, Inc. $ 41,596.20 3. Cone / Giralt Enterprises $ 2,235.00 4. Cone / America's Best Products $ 3,700.00 5. Cone / Ace Asphalt $ 2,000.00 6. Cone / ABC Barricades $ 2,064.36 7. Cone / C3TS $ 2.117,50 Balance to Cone Constructors, Inc. $ 5,647.88 We will appreciate the Village of Key Biscayne accommodating our request to process final payment in this manner. Please contact us if you have any questions or comments. Sincerely, BUN O ON, INC. - - Richard . nell President 7801 n w 66th street / miaini, florida 331 66 foundation piling • seawalls • cofferdams • marinas • bridges drilled shaft construction • cast in situ retaining walls - Injection grouting marine engineering contractors in south florida since 1 91 1 Vitiate Gr nr,( Joe I. Reece. Mr).r Gregory C. Han. Vier Me7.r Scott Bess Mucha Fdea-Leen Broucek Alan H. Fan Mortimer Fried Rg$,e,r O1d,kr...vicI Vigez . Mew igrr C Samuel Kissinger VILLAGE OF KEY BISCAYNE Office of the Village Manager July 29, 1999 David Wolpin, Esquire Weiss, Serota, Helfman, Pastoriza & Gucdes, P.A. 2665 So. Bayshore Drive Miami, Florida 33133 Dear David: San O f k, \✓-e a f l' --°A" wig s f ieerc-e /r u �'7/s /99 Enclosed please find a copy of the Final Payment Request from Andrew C. Pierce of C.A.P. Engineering, dated July 19, 1999, addressed to C. Samuel Kissinger. As noted in the memorandum, Mr. Pierce has requested that you review the documents. We would appreciate it if you would examine the enclosed material and notify me and Mr. Pierce of your recommendations. Thank you. Sine C. ' amuel Kissinger Village Manager CSK\cpg enclosure . 85 West McIntyre Street • Key Biscayne, Florida 33149 • (305) 365-5500 • Fax (305) 365-8936 MISSION STATTUENT:'T0 raov1oEA LIFE QUALITY COMMUNITY ENVIRONMENT FOR AI I ISLANDERS TIIROUCH RrSPONsme COVIRNMINt — A6 C.A.P. Engineering Consultants, Inc. Nir /'s t- 1 'c' FAX TRANSMITTAL it Date: Id Mil Project No: ifUtiir MAS tr1 got�r 1 To: ' � +9 Wi Z { 11Ni From: CWPtWi-J fir C�?°- e Company:, h) fiSs 4o .P Number of Pages: 6 ORClud+no cover sheet] Fax No.: ( 34)S } 8s - z32 REMARKS: y_J✓1.9, l iG Uf1r,f Is PAD 4fi 5t411- fir flPe Ep_l 11* f * c-ur /c)41. 1 $tJ F) (I r», c.T6ry Ct/a/=..b -roe �iGi, r1 7P /55v,`" 50/ ' Cl fc tc.s gips tap d r1! r 4.i ilJ 7 v1� -1)4f" f- c. -trC co v t, 6 t7 T14 Ccvvv v6 ltr u ;c -vv i e Cv t eJ P 1 VD r✓ t isW ckaJm o , 71114. len-v t-- moo rfI etj 1'440 . fk1 If traosmi ted material Is not received as noted. please Inform us immediately. 100 Miracle Mile • Suite 300 • Coral Gables, Florida 33134 • (305) 451-5484 • Fa (3O5)351-549•= t0'd t,6t9-I917 5o£ "�Lsu' 6ui.,iaaui6u3 "d-b' V/30: II 66-SZ-iaO I UNPAluitavMTAil 'U 7.1 V 7•• --. 0.100 . PC lee 8ush Governer ectidve AdmGtdetraro Engineering Section 1725 N. W. 167th Street Miami. Florida 33056 September 2, 1999 W do J. Pevida, PE Co o Castello Crballo Thompson Salmon 90 Ponce de Leon Blvd, Suite 900 Co al Gables, Florida 33134 Project Name: West Mashta Drive Bridge Address' Key Btscyane Permit" 125469-399-DSGP Issued: 08/11/98 r Mr. Pevida. Robert 0. Stooks M.U. ScaersrL Th s will serve to acknowledge receipt of request for a Letter of Release to place water Supply system �n aervicc. B d on the FAgirteer's Certification and satisfactory pressure test and bacteriological results, we are rel acing these facilities for service. In a.se of a Partial Release it will be the En ,lneer's responsibility to secure complete clearance of the eet project prior toplaccing the entire system in service. Failure to comply with this requirement wil constitute a cause for Enforcement Action. Yojr continued cooperation in our water supply program is very much appreciated. Julia olc, P_E. 5wit Elrnir. M 3 . P.! . anvueenientd Adm;nt i,te M,3mi.Dadt COunty flurry t ep4Lnr+URavi►enn.eeal ,0% Iris N.W. tor• Elm, won.. Rasp 31016 TEL (301) 623-1500 • FAX (305) 623.3302 Bmeit, 3tinic a1.nlr�da�.WNt A.ec WebvKi wwvr4.IthesIN Ora TOTAL p' .etc' 10/22'90 FRI (3:01 FAX 305 6887737 INSPECTION UNIT 0 00 2 MEMORANDUM G? , w• w., TO: FROM: Jose Soto DATE G'GI-. 1 I , 19 9 9 System Records & Permits Supervisor E.T. Parada Jr. Chief Inspector Field Operations Section SUBJECT: Job Completion E.R. Numberb S9 So1 1 F.B. Number — The Sewer Collection System for E Sr I-1 Ft S N T A w E R 1 p C E located at • HT A & 4 }-ivkgl C. tie. 1-k1644 IZ been completed. Contractor ,,,1 L o t S` - • Enclosed: Mylars I , Blue -lines_ 1 , and Field Iiociks. Recorded Plat Enclosed. (One Copy to Plans Review, one copy to New Business.) NON-Recorde(1 Plat Enclosed; Signed by Miami -Dade Public Works Plat Unit Design Engineer(s) Eotiz6, CA sue` A_yCa2SNALt- -t'yQ‘kpSo&JI SAl,w A r-) A-• As-BuiltEnginccr(s) 4RtIli 6EAtt.) LA aD St J .j oAS, mac , cc: Tomas Goicouria, Utilities Development, New Business Manager Elio Calvo,Fixed Assets Supervisor Jerry Gomez, Hydrant Shop, Medley ' Marla Santa Cruz, Wholesale Billing File MEMORANDUM 1o,.., I7,. w. S 0 Jose Soto System Records & Permits Supervisor FROM: E.T. Parads Jr. Chief Inspector Field Operations Section LATE. DST SUBJECT: I ci ci 9 Job Completion B.R. Number 609 8 I oa F . Number The Water Distribution System for Ik\E ST l -t A j J DR., 0E. j3ft r._e located at � J . t-4 A, trrA 1, + Ht/ dAOE 44 -8. Q„ been completed. CAntraCtDr C4, 4l E C. ►J cs'r - Enclosed: Mylars I , Blue -lines_ , and -G Field Books Recorded Plat Enclosed. (One Copy to Plans Review, one copy to New Business.) NON -Recorded Plat Enclosed; Signed by Miami -Dade Public Works Plat Uric Design Engineer(s)C404,,zo,C_Agi- , Ck&JA i tiomPsoN{9ALMAY, PA As -Built Engi iccr(s) C A Kt 8 E. A'' LAND S v RJ "-1.04S- cc: Tomas (}oieouria, Utilities Development, New Business Manager Elio Calvo,Fixed Assets Supervisor Jerry Gomez, Hydrant Shop, Medley Maria Santa Cruz, Wholesale Billing File