HomeMy Public PortalAbout09-0479 Parker CITY OF TYBEE ISLAND
BUILDING PERMIT
DATE ISSUED: 11-16-2009 PERMIT#: 090479
WORK DESCRIPTION SCREENED PORCH&STAIRS
WORK LOCATION 29 VAN HORN
OWNER NAME ROBERT H.PARKER
ADDRESS 2603 CAUSTON BLUFF RD
CITY,ST,ZIP SAVANNAH GA 31404-1448
PHONE NUMBER
CONTRACTOR NAME SAVANNAH RESTORATION INC
ADDRESS PO BOX 9351
CITY STATE ZIP SAVANNAH GA 314129351
FLOOD ZONE
BUILDING VALUATION
SQUARE FOOTAGE
OCCUPANCY TYPE P
TOTAL FEES CHARGED $ 0.00
PROPERTY IDENTIFICATION#
PROJECT VALUATION $7,500.00
TOTAL BALANCE DUE: $ 0.00
It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire,
soil and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including
all environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be
approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction
covered by this permit.
This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted
work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided
unless work has begun within six months of the date of issuance.
Signature of Building Inspector or Authorized Agent: • A ALA
P.0.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328
(912)786-4573-FAX(912)786-9539
www.cityoftybee.org
,44,,,,-,,,„_t, City of ~bee Island • Community Devel( lent Dept. `%
,w Inspection Report i
e/ 403 Butler Ave. • P.O. Box 2749 • Tybee Island, GA 31328 -��`
vq INTERNATIONAL
Phone 912.786.4573 ext. 114 • Fax 912.786.9539 CODECOUNCIL
��
MEMBER
1
Permit No. 1 9 n 4 1 ci Date Requested (C) r 2 3 - i 0
Owner's Name P6r k Qs- Date Needed lU " Li ` I 0
f , c
Gen. Contractor ( :i k Tp‹-.1,-.Dra4nn Subcontractor 5 5 al" E I e C
Contact Information Le < ( 2, ) L `t - 51 0 I
Project Address 7 q Vo , o r '-m
Scope of Work CC f C..o r\D_ct --7) .') r k -4'" 4K-A ,,
Inspector 1 1 Cl Date of Inspection to Z`/ (,-7
Inspection -P. iN rJ P\ o c . ----` ', Pass 0, Fee
MI --,X-14i-r. ---4f
('0154JE - 40 CV( / ci20r7 a4 },(vim w f£) i..S...
Inspection 1 ti,CN ( 1:7L\�-- - Pass 9,-- Fail Fee
LJ
Inspection • Pass 0 Fail ❑ Fee
Inspection Pass ❑ Fail ❑ Fee
Nov 16 09 11 : 04a 9122341F' 7 p. 1
cc k,--
r'c ;. .
ti v° • Pressure treated with Micronized Copper • Hollow core makes columns lighter weight -' ,
;' Quaternary (MCQ) preservative for protection and allows hidden electrical wiring
h'' from rot, fungal decay and termite attack
.. •Structurally sound `
,g1 •YellaWood Select®KDAT (MCQ)
si
l �� • Higher strength ratings than other
•Paint or stain without waiting, thanks to glue-lam wood columns _`
being kiln dried
• Sold in small units for improved ;.
44 • Paint or stain with more ease, thanks stock rotation
i
to MCQ's lighter color _"
ate' •Treated with the only wood preservative r
u,
• Less likely to split, crack or twist to receive SCS certification as an 6§,
Pi than solid timbers Environmentally Preferable Product (EPP)
• Bonded with a waterproof adhesive • High grade lumber with small knots r
Hollow core makes
N column lighter weigh —zA. x4.
Q1,! .
__-_-_,..,..---,-5::::. ti t 11 it
-,...- --#~ Ready to paint or stain i ill I i i
ii immediately i.- "'ii iIi fU 01 t I S , f j
.r 1 ly t
t
rY 1 j
High grade lumber '�F ../IT'4;
Mi..-CAI . ► - •'` with small knots
i '
__,a,F r•-11.••'`s."�sr� es` I nrrfr �. +
6"x6" 8"x8" 10"X10" 12"x12" .
: : Available in lengths of: 8', 10' and 12' * _
`Actual lengths are�fz"shorter than nominal length above. t°
i, C l \6 I tJ - (0(03 -""o Z.
lit ti`s
Nov 16 09 11 : 04a 9122341F' 7 p. 2
e! x3A.
9a r
ti LAMINATED BOX COLUMNS TECHNICAL DATA
' The following load table was derived from the 2005 National Design Specification,
:t published by the American Forest& Paper Association and American Wood Council, and
physical testing performed by Timber Products Inspection, Inc.
z,,
General Loading Information ;1 s
i 1.The allowable loads indicated are based upon normal load durations during a 'f
controlled test at sustained temperatures less than or equal to 100 degrees Fahrenheit.
2.The provided values can be used in wet or dry service conditions. "'f
tk,,,
9,
3.The provided values do not compensate for reduced net section areas due to borin '
Pk: p p 9� ,,?
grooving, notching, etc.
€'`:r 4. Loads are based upon a pin-pin configuration with all loads acting at the center of the
I
column. No eccentric loads have been considered.
el 5. Loads are based upon column ends bearing on a durable, rigid, homogenous _
material with sufficient stiffness to evenly distribute the applied load. __ .
:
8 t
'�
eart k
7?
E.^y
to
YELLAWOOD® COLUMN SPECIFICATIONS
COLUMN SIZE . ;
STRUCTURAL LOAD VALUES fiYr
r pbs) _
At NOMINAL ACTUAL
6x6 51/a"x51/" 8,500
8 x 8 7" x 7" 11,000 ,s-1--'''
t 10 x 10 9"x 9" 13,500
""
12 x 12 11 n x 11" 16,000
Li: ;4"V
44 A 1lrellaWoo�•
i KDAT Pressure Treated Pine
po oReaT sounieRn
i` WOOD PReSeRVInGL.
's The above information was developed by Timber Products Engineering,Inc.(TPE)for Great Southern Wood's use only.The information provided Is specific to Great 4.
6,�' Southern Wood's laminated box columns as configured and tested In November of 2007. Use of this Information by other individuals or organizations without the 'y%„
E z express written consent of TPE and Great Southern Wood is strictly prohibited. For additional information about the data provided above,contact TPE at :Y
ii•.
Fai1"'r (205)617.9222 or(770)922-8000(ext.153).The columns should be installed only by a property certified professional in accordance with applicable building codes '„
and other laws and in a manner suitable for the specific application.These columns are for use in residential applications only.YellaWood®brand pressure treated ,;r
,'r' products(including YellaWood Select®)are treated with Micronized Copper Quaternary(MCC)using the MicroPro**'copper preservative system. Great Southern
.r; Wood Preserving,Inc.,Its affiliates and subsidiaries and TS()providers,use Osmos°,Inc.wood preserving products(MCQ),methods,systems and technology in the ''
treatment of YellaWood®brand and YellaWood Select®brand products.For more information visit www.osmose.com.For Important handling and other information
concerning our products or for a copy of the YellaWood®brand(including YelfaWood Select®brand)Material Safety Data Sheet(MSDS),please visit us at -;'
µ www.greatsouthernwood.com or write us at P.O.Box 610,Abbeville,AL 36310,YellaWood®,YellaWood SelectOand the yellow tag are federally registered trademarks
pi of Great Southern Wood Preserving,Inc. The Great Southern Wood Preserving,Inc.logo is a trademark of Great Southern Wood Preserving,Inc. MicroPro"'is a (.
trademark of Osmose,Inc. 098-08 ;;;
" i
1 " .
, " .
1 '