Loading...
HomeMy Public PortalAbout19940525 - Agendas Packet - Board of Directors (BOD) - 94-16 (2) u { r� � x�x t :.i +�,wyx��/��`�#fir+ ���' �•,'r• �� :., ys►.R ,.�`,�,�,�yal rr firyyr °`''� 1 Y 1 r1r� + "A r x•y. �r4.y 7 JAM ` 3101 Y rtLt .lgSr i Y ky MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. EMUNHUM FACILITIES INVENTORY AND EVALUATION Project Team: GOULD ARCHITECTS 255 North Market Street Suite 240 ' San Jose, CA 95110 (408)971-8826 ' BOLEY CONSULTING ENGINEERS 409 Alberto Way, Suite Two Los Gatos, CA 95032 (408)358-4560 SALAS O'BRIEN ENGINEERS,INC ' 305 S 1 Ith Street San Jose, CA 95112-2218 (408)282-1500 May 19, 1994 i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION TABLE OF CONTENTS ' EXECUTIVE SUMMARY Summary Chart SECTION 1 PROJECT SUMMARY Scope of Work Area Map ' Site Map Site Photograph ' Report Organization P g Summary of Conditions Recommended Interim Measures Building Findings & Recommendations ' Further Assessment Recommendations ' SECTION 2 BUILDING TYPE SUMMARIES Special Military Purpose Buildings Support Buildings rResidential Buildings SECTION 3 APPENDIX Drawing List Building Survey Charts 9335.01\TABLE.CON GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EXECUTIVE SUMMARY A. Study Objectives: The short-term objectives of the study are to: 1) Identify buildings that may have future public use potential; and 2)For those buildings with use potential, identify preventive maintenance needed to avoid deterioration due to weather or pests which would increase the cost of future use, or preclude the possibility. The longer-term objectives of the study are to provide the background information for a comprehensive plan for the Mt. Umunhum, area of the Sierra Azul Open Space Preserve. This includes the scope and cost of using, removing, or securing all buildings and infrastructure so that the area is ultimately safe for public use and consistent with the overall goals and objectives of the open space preserve. 1) Return the site to a natural condition to the extent feasible; 2) Provide support for passive recreational use; trails, staging areas, restroonis, signs and maps, patrol and maintenance. 3) Allow other public or enterprise uses where compatible with the above objectives. The study has not attempted to identify specific potential uses for the buildings, other than District operational needs and potential communication antenna sites. Specific potential uses of the buildings will be identified and evaluated during later comprehensive planning for the preserve, or if another party wishes to pursue a proposal independently. B. The Summary Chart: The Summary Chart in the Excutive Summary represents the findings of the study and indicates where additional cost information and assessment is needed to provide the basis for a complete plan and estimate for the disposition of the buildings. The chart summarizes the categories of buildings, the current condition of their various components, and the recommendations 9335.01/EXEC.SUM i GOULD"CHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION of the study regarding their use potential and further action by the ' District. Recommendations are based on the building's design, current condition, scope of repairs or upgrades necessary for public use, and in a few cases on existing or proposed use by the District, for operational or enterprise purposes. C. Second Phase Studies Spaces for cost information(and value in the case of potentially salvageable equipment or material) are provided in the chart; however, the budget for the first phase of study was not sufficient to develop all the cost information. Additional studies are ' proposed for the second phase to complete the costs and refine the recommendations. Some further technical studies or tests, such as for asbestos, or on the function of utility systems,may be beyond ' the scope of second phase studies,to be performed only if and when an actual proposal for use and/or demolition and site restoration is pursued. A complexse arate of buildings located 1.2 miles west of the P residential/support complex,known as the G.A.T.R. complex, was not inventoried in Phase I due to problems in obtaining access P g through intervening private property owned by Loren McQueen. If these issues can be resolved, these buildings will be studied in Phase II. Second phase studies may not provide complete cost estimates for the upgrade of all potentially useable buildings because such costs will depend in part on the nature of the proposed use, and because ' this effort is not justified until the interest in and appropriateness of such use is evaluated as part of overall preserve planning. Second phase studies will provide sufficient information for informed decisions about the use of the buildings and restoration of the site for open space purposes, and solicitation and review of other potential uses. This will include complete preliminary cost estimates for the demolition of damaged/unsafe/obsolete structures, ' or for securing and abandoning them where demolition may not be feasible. Costs for preventive maintenance on buildings which have use potential will be provided. Costs will be provided for ' 4335.01/EXEC.SUM 11 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION upgrade of buildings which are used or proposed for District patrol or maintenance support functions, unless additional technical studies or testing is required before the upgrade costs can be determined. In these cases a preliminary cost estimate will be provided for the additional studies. Also to be completed during the second phase study will be more detailed assessments of the infrastructure, particularly the water supply and sewage treatment systems,to estimate what improvements and costs would be involved in restoring them to use. D. Overview of Findings and Recommendations The Special Military P=ose buildings are typically unsuitable for other purposes and have serious damage or deficiencies. Many of the buildings and related utility and drainage structures present significant hazards for public use of the site, and should be removed or secured before public use is allowed. The special military buildings are clustered together at the east end of the complex on the highest point of the mountain. They are exposed to the harshest weather, are the most visually obtrusive, and suffered the greatest damage from the Loma Prieta earthquake. There may be some salvage value in some of these structures. Building 108 is a steel radar tower that could be dismantled and moved to another site for use as a lookout tower, as was done previously with a similar tower,Building 107. Buildings 110 and 119 are pre-engineered metal-framed structures that may have some potential to be disassembled and re-used. At Building 112, the Power Station,there are three huge diesel generators with a shared cooling system. These generators provided an independent power supply to operate the radar antenna and related systems. They had been sealed by the Air Force to prevent their deterioration and may have significant resale value. Electric power is available at the site from PG&E and electric service would not be a constraint for future use. The S=12ort Buildings and Facilities vary in condition and configuration. Most of these structures are in very poor condition and could not be restored to their former or alternative use for less than the cost of new construction. Some special-purpose 9335.01/EXEC.SUM jij GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION structures, such as the bowling alley or swimming pool, would not be desirable under any likely future use scenario. Many of the support buildings are prefabricated metal framed and sided buildings which may have some salvage value if carefully dismantled. There is some potential salvage value in fixtures such as the stainless steel sinks and the refrigerated cases in the commissary. One building in this category which does have clear future use potential is Building 211, the Motor Pool, which would be useful for housing District patrol and maintenance vehicles and equipment. The Residential Buildings are some of the most recently constructed structures and may have the most use potential. They occupy a more sheltered and less visually obtrusive area than the military and support structures,on a south-facing slope at the southwest end of the complex. The former base commander's house, a single-family structure, has been occupied by a caretaker and his family for the past several years, and a ranger and family have occupied one unit of a nearby three-plex for the past year. The residential units are in need of paint, weatherstripping, and measures to control rats and mice. They are otherwise basically sound, although they do not meet current code for insulation, double-pane glass, wiring and plumbing. There may be asbestos in ' some of the building materials such as floor tile. E. Utilities and Infrastructure The most significant constraint to the use of the residential structures,or to any significant use of the facilities, is the utilities and support infrastructure. Heat for the buildings is typically provided by oil-burning furnaces,with oil distributed by underground pipes from hilltop tanks. This system would be impractical to continue on a smaller scale and it has been damaged by the Loma Prieta earthquake. Parts of the system are planned to be removed as part of the Corps of Engineers clean-up of toxic contaminants on the site. New individual heating systems, either electrical or propane-fired, would be required for any building that is to be used for other than storage. Phones and electricity are ' available at the site and would not be a constraint, although there would be costs in extending and connecting the service. 9335.01/EXEC.SUM iv GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION A more serious constraint is the water system. The air force station ' water supply was derived from springs in a canyon approximately 1.5 miles south of the base complex. The water was pumped uphill to holding tanks and flowed by gravity to serve the fire and ' domestic water needs of the base. The earthquake caused landslides which severed the water line from the spring, and also damaged some of the distribution piping. Portions of the distribution system for fire are also damaged, deteriorated, or missing. The two housing units currently in use are served by a ' makeshift water system with two individual storage tanks filled by surface springs owned by adjacent property owner Loren McQueen. A tank to serve a portion of the fire system is also filled from this source. However,this supply would not be adequate to serve more extensive use of the former Air Force Station. ' The sewage treatment system for the base included primary and secondary treatment facilities and a disposal field, as well as septic tanks. Currently, only the septic tanks are in use. The condition of the sewage treatment facilities and equipment and their useability under current codes remain to be determined. Roads, parking areas, and sidewalks are generally in serviceable condition in the station complex, although there is the same ' localized damage, primarily due to the earthquake, particularly in the vicinity of the hilltop radar tower. Filling of cracks and a new seal coat over the entire surface are called for in areas that would be retained for future use. Landscaping and site fixtures such as signs, fencing,retaining wails, and lighting are quite deteriorated since the days when the Air Force station was maintained. Some of the landscaping has died and some has overgrown the sidewalks and structures. All of it is non-native material which should be ultimately removed or gradually succeeded by natural vegetation. 9335.01/EXEC.SUM v GOULD ARCHMCTS i i i i i i i i i i i MT. UMUNHUM SUMMARY CHART OF BUILDINGS/FACILITIES 5/18/94 .c m � O CD 4 U ' U N C) O h 0 h C_ r o 3 m' o a y o m w co h p U U O L IL 7 C O d1 v O h _ o C m w C « a> Q ID O .G m O ¢ o LL h ` o m y u m H w cn o 0 h o o .� o o m SUBTOTALS CURRENT CONDITION OF BUILDING/FACILITY Parking, roads, grading rt — _ N/A Architectural :::: Structural _.. Plumbing N/A N/A N/A N/A ........................... HVAC N/A N/A N/A Electrical N/A - N/A OVERALL CONDITIONS POOR POOR FAIR G07D GOOD FAIR GOOD POOR Interim safety/security(cost) Demolish (cost) Secure/Abandon (cost) Salvage (value) Subtotal USE POTENTIAL NO POSSIBLE NO POSSIBLE POSSIBLE UNLIKELY UNLIKELY UNLIKELY Interim safety/security(cost) Preventive Maint. (cost) MROSD existing or proposed use (Upgrade Cost) Subtotal Additional studies required(cost) TOTALS Damage/Deficiencies Damage/Deficiencies Damage/Deficiencies VI MT. UMUNHUM SUMMARY CHART OF BUILDINGS/FACILITIES 5/18/94 C w O 0 Q = y .0 T O n Y a a E u a 7 2 C 0 L m V) w � a) N £ y Z � O C C LL 0 �tS o U � L N CO > U m act > 4 Lf `c E 0 o a o 0 y O (V Q m ,,, g SUBTOTALS CURRENT CONDITION OF BUILDING/FACILITY Parking, roads radio a 9: grading Architectural tura c Structural ?>::,za;::;;;:::;:;: Plumbing HVAC N/A Electrical OVERALL CONDITIONS FAIR POOR POOR Interim safety/security(cost) Demolish (cost) Secure/Abandon (cost) Salvage (value) Subtotal USE POTENTIAL NO POSSIBLE UNLIKELY Interim safety/security(cost) Preventive Maint. (cost) MROSD existing or proposed use (Upgrade Cost) Subtotal Additional studies required(cost) TOTALS Damage/Deficiencies Damage/Deficiencies Damage/Deficiencies VII MT. UMUNHUM SUMMARY CHART OF BUILDINGS/FACILITIES 5/18/94 C 0 � L _ N p M U Of 7 N 2 a Co O Qt m ip w A? ❑ c d F Cr E o. E H E o c a4 y @ o O a d y E o o N y E o 'a y yL co Z En C Q C N N 0 N N N N N N SUBTOTALS CURRENT CONDITION OF BUILDING/FACILITY Parking, roads, grading ........ Architectural y.:.:.r ur l Plumbing HVAC Electrical OVERALL CONDITIONS POOR FAIR FAIR FAIR FAIR FAIR POOR Interim safety/security(cost) Demolish (cost) Secure/Abandon (cost) Salvage (value) Subtotal USE POTENTIAL UNLIKELY UNLIKELY UNLIKELY POSSIBLE NO UNLIKELY NO UNLIKELY Interim safety/security(cost) Preventive Maint. (cost) MROSD existing or proposed use (Upgrade Cost) Subtotal Additional studies required(cost) TOTALS Damage/Deficiencies Damage/Deficiencies Damage/Deficiencies VIII MT. UMUNHUM SUMMARY CHART OF BUILDINGS/FACILITIES 5/18/94 m in a C C C C C Y Y C N O a � y B d 41 m C c o] y vi ° -v E C o Y 4 E E a o o ai E L o E °' `o � E y o f m > > 3 e > U ,�, = C Q U) M C O , O O y Lo N O Co @ N L N N U) N N 2 SUBTOTALS CURRENT CONDITION OF BUILDING/FACILITY ...................................................... ........................... ........................... ........................................................ ....................................................... ........................... Parkin roads radio 9. grading Architectural Structural Plumbing N/A HVAC N/A N/A Electrical »»'s»s3.. N/A OVERALL CONDITIONS FAIR kPOORGOOD POOR FAIR Interim safety/security(cost) Demolish (cost) Secure/Abandon (cost) Salvage (value) Subtotal USE POTENTIAL UNLIKELY UNLIKELY POSSIBLE NO NO Interim safety/security(cost) Preventive Maint. (cost) MROSD existing or proposed use (Upgrade Cost) Subtotal Additional studies required(cost) TOTALS Damage/Deficiencies Damage/Deficiencies Damage/Deficiencies ix �I Irr, � .■� r tlr r r� � i■. r MT. UMUNHUM SUMMARY CHART OF BUILDINGS/FACILITIES 5/18/94 c y `6 o t rE X o o a rn m m m O V N to N fn y 0 C Iv C1 y E E m EQC z E v E ro E ro It E v E ro <t E cti L -r3 -ra MML to O O O oM°: O :: o C14u t;N U to o Oo , SUBTOTALS CURRENT CONDITION OF BUILDING/FACILITY Parking, roads grading ""'' Architectural ... ............. :::::::::::::::::::::::::,::::::::. :::.::::. Structural :::::::.... .::::::::::. ::::.:::::::::::::::.•::::.::::.. :.»:... Plumbing N/A HVAC N/A Electrical N/A ;;;•.>::•::•>:.::: OVERALL CONDITIONS POOR FAIR FAIR FAIR FAIR FAIR FAIR GOOD Interim safety/security(cost) Demolish (cost) Secure/Abandon (cost) Salvage (value) Subtotal USE POTENTIAL UNLIKELY UNLIKELY POSSIBLE POSSIBLE POSSIBLE POSSIBLE POSSIBLE POSSIBLE Interim safety/security(cost) Preventive Maint. (cost) MROSD existing or proposed use (Upgrade Cost) Subtotal Additional studies required(cost) TOTALS Damage/Deficiencies Damage/Deficiencies Damage/Deficiencies x MT. UMUNHUM SUMMARY CHART OF BUILDINGS/FACILITIES 5/18/94 o� C a m rn j c c C� D :3 7 7 ,W O O w 2 2 ESE EEC U- O 3 " SUBTOTALS CURRENT CONDITION OF BUILDING/FACILITY Parking, roads, grading Architectural Structural Plumbing HVAC Electrical OVERALL CONDITIONS GOOD FAIR Interim safety/security(cost) Demolish (cost) Secure/Abandon (cost) Salvage (value) Subtotal USE POTENTIAL POSSIBLE POSSIBLE Interim safety/security(cost) Preventive Maint. (cost) MROSD existing or proposed use (Upgrade Cost) Subtotal Additional studies required(cost) TOTALS Damage/Deficiencies Damage/Deficiencies Damage/Deficiencies XI t SECTION 1 Ili PROJECT SUMMARY MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 1 PROJECT SUMMARY A. Scope of Work: The purpose of this report is to present the Midpeninsula Regional Open Space District(MROSD)with an inventory and evaluation of the existing facilities at the former Almaden Air Force Early Warning Radar Facility. Gould Architects and its consultants have conducted a survey of the site and building elements as well as an examination of the existing Record Drawings to determine the history and physical status of each building and utility system. This report provides a general assessment of the facilities including damage, deterioration and deficiencies relating to safety, security, current codes and standards for the structural, plumbing, HVAC and electrical systems based on our limited observations. Maintenance and upgrade recommendations are based on general observations. To make specific recommendations, further assessment and evaluation will be required. B. Report Organization: This report begins with a review of the overall facility followed by specific Building Type Summaries that include a General Description, Field Observations, general Maintenance and Upgrade options, and Preventive Maintenance Measures for each building or building type. These options are categorized as follows: 1) Maintenance and Repair Measures for Limited Non- Public Use: This option reflects the minimum amount of work required to make a building reasonably safe for limited, non-public occupancy without consideration of codes and regulations. 2) Upgrade Measures for Public Use: This option assumes a building will be occupied by the public. In most cases additional assessment will be necessary to determine the extent of work required. Accessibility measures for the disabled are not included in this report. This will require further study of the site and buildings. This should be done after the disposition of each building is determined and an accurate topographic survey of the site is performed. 9335.01/PROJECT,SUM 2 GOULD ARCHITECTS Los Gatos 1 _ ON Lexin -�•r t `.i lti- L o Res HIGHWAY 17 � _.r.•,•'.:. :'-. ••� v "•: ;• c SODA SPRINGSR'` roso WOODS RD. sG ,.L..;_.~•: t. ` AIR FORC �oMP` v STATION SITE Z i LEGEND 1 •. '? `CATTERMOLE RD. . i �� _ Boundary or sphere of influence c^ ::�?., �•.l 1 :+-V'' c of the Mid peninsula Regional " 1 �-�' �l �` t Open Space District lX.:• :. ''^ ) 1 Midpeninsula Regional Open Space s':�:•t'�;; �:; District open space preserves }: Institutionallyownedlands ';_,;,• ••s ;� ' MT. UMUNHUM PLANNING AREA MAP Scale: 1 " = Approx. 5,000' I i - Page 3 - �` -J . PRELIMINARY USE SUITABILITY DIAGRAM II N KEY TO SYMBOLS I _ALMADEN AIR FoRcE srAreoN STRUCTURES SPECIAL MILITARY - v EXISTING PERMANENT ROADS B PARKING PURPOSE BUILDINGS Z., �--'1;6_EXISTINO PAVED .mot-'aa^••�^ - / • +0 `� l ?t�SyE rA OE SPq�rFfELO + E%19TIN0 GRAVEL } '- `� �- - , _. BOUNDARIES )I I41� 8124�1 -- — PROPERTY LINE �`� �d 300A SEWAGE OXIDATION) POND \ \ 140 11 ti —X— SECURITY FENCE i 300B SEWAGE OXIDATION POND �IK 303 PAINT STORAGE , ` I 0 10 310 SEWAGE SEPTIC TANK ` \\,J. >> 'g I I 311 SEWAGE SEPTIC TANK I ��+ ti� - X_ OPERATIONS � 300E SEWAGE PUMP STA.. 3000 SEWAGE CHLORINATION ; OA •A + 415 HEATING FUEL STORAGE / 300C SEWAGE TREATMENT I {�� a / 420 MOGAS STORAGE 421 VEHICLE FUELING STA. TO G.4.T. SUPPORT BUILDINGS BB4A --�_ (-N (NOT STUDIED? AND FACILITIES ■zoo- � �- • w; � �.` ..-, zll 8•j 66qe 1 FLAG POLE I G A.T.R. v206 r 20 ♦415 �! 100 OPERATIONS 700 I /� - L� ` yl •9 102 RADAR TOWER FPS-24 1 7I��. 1.2-'LEI TO 713 104 PAINT STORAGE - 11 l OPERATfON9 , 105 PROTECTIVE SHELTER s �..__��' R �■ 108 WATER STORAGE TANK 700 COMM.TRANS/RCVR.(G.A.T.R. BLDG.) 115 1 107 RADAR TOWER FPS-90 !r. •, e� V 711 HEATING FUEL OIL STORAGE N 108 RADAR TOWER MPS-14 712 SEWAGE SEPTIC TANK 110 TRAINING BLDG. 713 WATER STORAGE TANK ' ,•'•.. 112 ELECTRIC POWER STATION SEWAGE TREATMENT �, ti3 103 HELIPAD �__- �• 114 PAINT STORAGE 232 115 SECURITY SENTRY HOUSE ...•.•.......' 117 DIESEL STORAGE A III,B RESIDENTIAL ] 118 DIESEL FUEL PUMP BUILDINGS ( 119 C.E.MAINTENANCE SHOP LEGEND 120 WHSE,SUP. B EQUIP. NO USE POTENTIAL J- 124-130 FIRE HOSE HOUSE 140-143 SEWAGE SEPTIC TANK (DEMO AND RESTORE SITE) 505 CARPORT —� USE UNLIKELY 200 WATER PUMP 05 B.O.O. 232 FIRE HOSE HOUSE 506-509 FIRE HOSE HOUSE _, - (SALVAGE / RELOCATE, 2 510-517 FAMILY HOUSING / 206 FIRE HOSE HOUSE 233 BARRACKS (AMN.DORM),CHAPEL RESTORE SITE) FAMILY HOUSING 207 ORDERLY ROOM(SO.MO.) 234 FIRE HOSE HOUSE POSSIBLE USE 211 MOTOR POOL(AUTO.MAINT.) —J 212 NCO OPEN MESS (FURTHER STUDY 21D DISPENSARY REQUIRED) 215 FIRE HOSE HOUSE 245 RECREATION BLDG. ■60BADAM 217 BOWLING ALLEY 250 AUTO. MAINT. STORAGE E607 WATER PUMP 226 FIRE HOSE HOUSE 275 SWIMMING POOL loa o too 200 - Page 4 - GRAPHIC SCALE IN FEET i�� 'r+•rr`���J„t' _ gyp' � UL �: fi �` ,rf .f r AV �""'"\ `•"f.'� f�' �kS�'�a� �,L� �''���� ,r "art Y Om rn ��NW lit EN f. 9 S r. ar 2 ! LL[ TF � r'.'f� j✓ Y V MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 3) Preventive Maintenance Measures: This option reflects the minimum effort necessary to keep a building from continued rapid deterioration. 4) Demolition: The option to demolish a structure is based on the immediate hazard it poses to human occupancy or if the cost of repair or upgrade exceeds the cost of demolition. 5) Abandonment: The option to abandon a structure and barricade it from unauthorized entry may be appropriate when compared to the cost of repair, upgrade preventive maintenance or demolition. For the purpose of this report, we have divided the buildings into three categories: 1) Special Military Purpose Buildings: Buildings that served specific military functions. They are not likely to be reused that way again nor are they anticipated to undergo any modifications. 2) Support Buildings: Buildings that provided general support services to the facility. These need to be evaluated on a case-by-case basis to evaluate their potential use. 3) Residential: Family housing and airmen's dormitories which exhibit similar construction types and deficiencies. C. Summary of Conditions: The Mt. Umunhum facility (formerly Almaden Air Force Early Warning Radar Station) is an abandoned complex of military, 1 administration, maintenance, housing and recreational buildings, roads, utility systems, sewage treatment, and water supply and treatment facilities constructed between 1955 and 1975. Currently in varying states of disrepair, they are inadequate for use by the public due to their original special purpose design, outdated construction methods, damage from the 1989 earthquake harsh weather and vandalism. 1 The site in general is deteriorating due to lack of regular maintenance. The landscaping has been left to grow over paths, close to building foundations, over building structures and through 9335.011PROJECTSUM 6 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION cracks in the asphalt paving. Road conditions can be hazardous at times due to rock slides and a variety of cracks and surface failures along the edges of roads. Sidewalks, and curbs are cracked, causing hazardous uneven surfaces (exhibit 1). Landfill conditions appear to be suspect as to structural stability in a number of locations (exhibit 2). All the buildings show signs of overexposure to the elements. The lack of maintenance has allowed both the exterior and interior materials of the buildings to deteriorate. There is evidence of water stains and possible advanced dry rot and warped flooring. Foundations have cracked and failed altogether in some cases. Wall finishes have cracked and peeled, leaving underlying materials exposed to the weather and infestation. Roofs can no longer resist water intrusion (bubbles in flat roof membranes, deterioration of aggregate cap sheets, drying of caulking beads). Roofs in some instances have blown away and left the roof structure and interior finishes exposed to the weather. The lack of heating has allowed extreme changes in temperature and humidity, which has led to the deterioration of interior finishes and materials such as hardwood flooring and floor tile. The lack of maintenance has left the buildings subject to insect and rodent infestation. There is evidence of rat droppings, dead insects and, in one instance, an active bee hive. In a number of locations fuel tanks, electrical transformers, and miscellaneous equipment have been identified for removal. These apparently contain hazardous or toxic materials. The water distribution system has not been used for the last eight years. Its reliability and condition is in question because of recent seismic activity. Demands for water and new distribution systems must be evaluated for future use. Re-establishment of the water system may also be legally constrained. An easement for power supply to the pump runs across private property. This easement was specific to the military use and may also have lapsed due to lack of use. Also, the agreement with San Jose Water Works for use of the springs for water supply was specific to the military use and may have lapsed. These issues should be resolved prior to investigation of the physical requirements. The condition of the waste water piping system is also in question due to recent earthquakes. The percolation system of soil waste 9335.01/PROJECT.SUM 7 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION does not conform to current plumbing regulations per the Uniform Plumbing Code or the State of California discharge limits requirements. A new design for waste treatment would be necessary to reestablish significant use. The Electrical Power Station (Building 112) provided underground power through diesel generators to many of the buildings. It is probably infeasible to continue to use this as a source of power. Currently, the site is only partially serviced by P.G.&E. lines. D. Recommended Interim Measures: If demolition, repair or upgrade work is not anticipated in the near future, interim measures should be implemented, where appropriate, to reduce the rate of deterioration for buildings which are determined to have use potential and limit the possibility of injuries where hazards are presented. Examples of these measures include: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Repair or replace damaged or missing guardrails. • Shore up undermined foundations. Install barricades/fences around these areas. • Patch holes in floors, roofs and walls. • Remove damaged light fixtures,walls, ceilings, etc.. Clean up and remove debris. • Remove collapsed structures such as decks, fire hose houses, etc.. • Drain cavities in buildings that have collected rain water. • Close openings to prevent insect and rodent infestation. • Install temporary retaining walls, netting, etc. to prevent further soil erosion. • Prune/remove overgrown vegetation around buildings. • Repair uplifted portions of paving. Fill in cracks. E. Building Findings and Recommendations: 1) Special Military Purpose Buildings 100 Operations Building 102 Radar Tower(concrete structure) 103 Helicopter Landing Pad 9335.01/PROJECT.SUM 8 GOULD ARCHITECTS --------------- MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNTUM FACILITIES INVENTORY AND EVALUATION 105 Fallout Shelter(underground) 106 Wind Measuring Set 107 Radar Tower(foundation only) 108 Radar Tower(steel frame) 110 Training Building 112 Electric Power Station 114 Sheet& Pipe Storage 115 Gate House 117 Diesel Fuel Pump House 119 CE Maintenance Shop 120 Warehouse Supply& Equipment a. Summary: The buildings in this category served specific military functions or were necessary to provide independent utility systems to support the military fuctions. It is unlikely with some exceptions, that they are adaptable for other uses. These buildings are located on the top of the mountain in a jcompound located about 800 feet from the "Cantonment" that includes the support and residential structures. These buildings exhibit structurally diverse styles such as an underground fallout shelter, a steel frame tower, a massive poured in place concrete multi-story radar tower, concrete block and pre-engineered metal buildings. Power to Buildings 110, 115, 119, 120 and 200 was provided by the Electrical Power Station (Building 112) whose generators may or may not be operational. Use of generators for back-up power was based on the military mission and would not be necessary or economicallly feasible for other uses. Any electrical and mechanical repairs and upgrades will be dependent on the availability of power from PG& E. 1 �I Buildings 110 and 119 are pre-engineered metal-fram ed "Butler" buildings which may have some potential to be dismantled and relocated for other use. This type of building is described in more detail in the Building Type 1 Summaries. 9335.01/PROJECT.SUM 9 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION For the most part the buildings are in very poor condition and pose significant safety hazards. None of the facilities were built to meet current code or access compliance regulations and it would be economically infeasible to upgrade any of the structures to code compliance. b. Recommendations: All buildings in this category should either be demolished or secured and abandoned. Due to their special purpose design and poor condition, there is little likelihood of adaptation for other uses and it would be less expensive to build new buildings than to reuse them in any case. Because of the age of these facilities, and from our site observations, it is assumed that materials such as floor tile, insulation and plaster may contain asbestos or other hazardous/toxic materials. We recommend further inspection to determine the extent of contamination. 2) Support Buildings 200 Water Pump Station 205 Bachelor Officers' Quarters 207 Headquarters Squadron 211 Auto Maintenance Shop 212 NCO Open Mess 213 Dispensary 217 Bowling Alley 225 Airmen's Dining Hall 230 Commissary 245 Recreation, Multi-purpose 250 Auto Maintenance Storage 275 Swimming Pool 276 Bath House 300 Sewage Treatment/Disposal Plant 303 Paint&Dope Storage 415 Heating Fuel Storage 420 Mogas Storage 421 Vehicle Fueling Station 600 Water Pump Station 601 Water Storage Tank 602 Water Storage Dam 9335.011PROJECTSUM 10 GOULD ARCHrFECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT t MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 607 Water Pump Station 880 Fuel Storage Tank 884 Water Storage Tank XXX Fire Hose Houses Sewage Septic Tanks a. Summary: These buildings accommodated military staff support services. For the most part they are in very poor condition and have significant safety hazards. None of the facilities meet current codes or access compliance regulations and it would be economically infeasible to upgrade any of the 1 structures to compliance. In surveying them, a number of deficiencies became apparent that were common to most. A general master plan along with a more thorough accounting and analysis of each will be required to determine if any of these facilities can be used in the future. The buildings are structurally diverse and include concrete block, metal and wood framed buildings, pre-engineered metal buildings,poured in place concrete structures, as well t as a number of metal storage tanks and a helicopter landing pad. Many of these structures are in very poor condition. There are, however, a number of them that appear to need just minor maintenance. Buildings 110 and 119 in the military compound, and support buildings 200, 205, 207, 211, 212, 213, 225, 230 and 250 are pre-engineered metal frame with metal siding and roofs. The corrugated siding and roofs, generally, are in fair condition with signs of rusting. However, there are numerous places of minor damage that affect the buildings' ability to remain weather tight. Heating, ventilating and air conditioning equipment are in poor condition. Electrical wiring is in fair condition. Lighting is in very poor condition and in man cases resent a serious safe hazard Y P safety due to the failure of hanger attachments. b. Recommendations: Generally, the pre-engineered building shells are in fair to good condition. With a minor amount of work, the building shells could be rehabilitated, but most of the interior work including lighting and HVAC requires complete 9335.01/PROJECT.SUM 10a GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION replacement. These buildings may be functionally obsolete jwithout full rehabilitation of the interiors and HVAC/electrical work. The concrete masonry buildings are generally in good condition. Similar to the pre-engineered buildings, the interior and mechanical/electrical systems need to be completely replaced or rehabilitated to make the buildings useful. Because of the age of these facilities, and from our site observations, it is assumed that materials such as floor tile, insulation and plaster may contain asbestos or other hazardous/toxic materials. We recommend further inspection to determine the extent of contamination. 3) Residential Buildings 229 Airmen's Dormitory (foundation only) 231 Airmen's Dormitory (foundation only) 233 Airmen's Dormitory&Chapel 240 Airmen's Dormitory (foundation only) 242 Airmen's Dormitory (foundation only) 244 Airmen's Dormitory (foundation only) 505 Carport 510-514 Family Housing(Fourplex) 515, 517 Family Housing(Triplex) 516 Family Housing(Detached Single Family) a. Summary: The buildings in this category are all residential or residential support facilities. Two units are currently toccupied by a District caretaker (building 516) and ranger (building 515). Most of the Airmen's Dormitory buildings have been demolished except for the concrete foundations. Building 233 remains intact but is in very poor condition and poses a safety risk. The family housing units consist of five, 2-story, four unit flats; two, 2-story, three unit buildings; and one detached 9335.01/PROJECT.SUM 10b GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION single family house. All of these buildings are wood frame construction with concrete foundations. Some units are still in reasonably good condition with only minor damage, others, especially the lower 4-plex units, have suffered significant damage. Water leaks from the roofs and windows and pest infestation are the most common damage to the interiors. There is also significant damage to the interior and exterior finishes. None of these buildings have been built to meet current codes and regulations, however, some of them have a potential for reuse. b. Recommendations: The remaining dormitory building (#233) that is left intact is in poor condition. It should either be demolished or secured and abandoned. It would be less expensive to build a new building than to rehabilitate it. Because of the age of these facilities, it is assumed that materials such as floor tile, insulation and plaster may contain asbestos or other hazardous/toxic materials. We recommend further inspection to determine the extent of contamination. The family housing buildings exhibit little damage from the 1989 earthquake. The HVAC, plumbing and electrical systems appear to be in fair condition and can be renovated to habitable standards. These buildings can be rehabilitated to serve as residential units again as evidenced by buildings 515 nand 516 which are currently inhabited by a ranger and the facility's caretaker. F. Further Assessment Recommendations: Because the scope of this report does not include a comprehensive study of the facility, further assessments may be necessary including, but not limited to: • Salvageable material (diesel generators, mechanical and electrical equipment, fixtures, pre-engineered buildings, or 9335.01TROJECTSUM 10C GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION special materials such as copper and stainless steel) and whether it can be recovered cost effectively. • Asbestos contamination. • Geotechnical survey to determine the stability of the cut and fill material. • Accessibility for the disabled including site access, parking, path of travel and building access. • Cold water distribution. • Waste treatment. • Structural damages relating to long term occupancy of site. • Cost to extend PG&E service. • Detailed cost estimates for both construction and demolition. 9335.01/PROJECT.SUM 10d GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION JrrI t k -'.'iS" _3v� r ram• � .t��,,�1 `q y �r�,� 5 � .. .w r � -ti View of loose rock at access road 9335.01THOTOTG 11 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 44 y View of landfill at Building 114 and 112 9335.01\PHOTO.114 12 GOULD ARCHITECTS SECTION 2 i BUILDING TYPE SUMMARIES 1 � 13 i J SECTION 2 BUILDING TYPE SUMMARY - SPECIAL MILITARY PURPOSE BUILDINGS Building 100 Operations r � Building 100 - Operations GENERAL: 4 000 square foot pre-engineered building was built in The original q p g g ' 1955 with two subsequent concrete block additions of 2,000 square feet and 1,450 square feet in 1957 and 1959 respectively. Radiation shielding was added in 1963. The floor is a concrete slab on grade. The building was heated by a steam boiler and air conditioned. The sanitary sewage was fed to a septic tank. Electrical power was provided by Building 112. ' FIELD CONDITIONS: The existing structure appears to agree with the record documents. The asphalt paving around the building is cracked. 9335.01\BUILDI00.DOC 14 GOULD ARCHITECTS The roof gutter system is damaged and pieces are missing. Roof flashing on the east side is damaged. The roof over the concrete block additions have either collapsed or blown off exposing the roof framing. The roof over the metal skin building (Butler Building) appears to be in good condition. Many of the windows are broken. Doors have been boarded over. There is evidence of rodent infestation inside the structure. There is considerable water damage in the ceilings and walls. Suspended ceilings have come loose from their supports. Light fixtures are loose and many are lacking lenses. Large deposits of sand are on the floors (apparently through cracks in the radiation shielding walls). The concrete masonry building sustained significant seismic damage to the walls and building interfaces. The heating and air conditioning equipment are in poor condition. The electrical and lighting systems are damaged. EVALUATION: Restoration of this building is impractical. The required repair and maintenance measures would be extensive and are listed as follows: • Due to the age of the building, the composition of the floor tile may include asbestos. Further investigation by an abatement contractor is recommended. • The building skin requires a considerable amount of patching and refinishing. Windows/glazing and doors/jambs need to be replaced. The roof over the concrete block buildings needs to be replaced and reroofed. The metal skin building needs to be tested and fitted for resistance to water infiltration(replace of gaskets and sealants). • All flooring materials need to be removed and replaced. The concrete floor slabs should be tested and repaired of all cracks. Damaged partitions need to be removed and replaced. Suspended ceilings need to be replaced. 9335.011BUUD100.D0C 15 GOULD ARCHITECTS • Permanent repairs to cracks and new structural ties are required to ' upgrade the building. Further exploration of the roof framing is necessary. ' • None of the mechanical and electrical equipment is repairable. A new oil fired steam boiler is needed to heat the building. New compressors and condensers are needed to cool the building. Exhaust fans may be repaired. Toilet rooms require new fixtures. Preventive Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceiling finishes, etc., clean up and remove debris. • Remove collapsed structures. ' • Close openings to prevent insect and rodent infestation. r 9335.01\BUn D1oo.DOC 16 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 100 Structural Evaluation Operations BUILDING DESCRIPTION: Building consists of four sections or additions; 3 CMU wall and metal roof structures; 1 metal frame and corrugated metal skin("Butler") building. Floors are concrete slab on grade with numerous utility trenches. EXISTING CONDITIONS: ' Numerous vertical cracks noted in the CMU walls and damage noted (cracked CMU/spalling) at interface of various building sections/additions. Roof framing is not visible. ' Metal skin("Butler") section in relatively good shape. Corrugated metal underground shelter relatively undamaged. Roof sections are missing over part of the building. PERFORMANCE EVALUATION: Building is heavy-duty commercial type structure, but has. sustained significant damage due to seismic activity and/or settlement of adjacent building sections. Roof skin appears to have blown off one whole section of the roof. MAINTENANCE EVALUATION: Cracks in the masonry walls(particularly large cracks at the building section interfaces) allow water intrusion into the structure. Large open cracks should be grouted or temporarily caulked to slow reinforcement rusting. UPGRADE EVALUATION: For continued use, building would require permanent (epoxy) crack repairs, tying or structural separation at building sections, further exploration of roof framing condition and repair of roof(new roof deck installation). ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1,500.00 ' Upgrade $58,000.00 Demolition $43,500.00 ' BOLEY CONSULTING ENGINEERS 17 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION O U ION Building 100 Mechanical/Electrical Evaluation ' OPERATIONS BUILDING HEATING, VENTILATING & AIR CONDITIONING ' SYSTEMS: Building heating was accomplished via an oil fired steam boiler. Boiler has been partially dismantled and is unrepairable due to age, deterioration and physical condition. Steam was piped to several air handling units which ventilated the building. These ahu's while they were at one time quality pieces of equipment,they are now in poor condition with all controls being ' dismantled,vandalized and unrepairable. Insulation has been damaged and integrity of piping systems is highly questionable. Air conditioning was available to this building via two R-12 compressors and water cooled condensers. One compressor has been removed; the other is in disrepair. These compressors are located in mechanical room MR#1 boiler room and violate current equipment room standards for refrigerant and open flames. This could not be renovated in the same configurations in order to comply with ASHRAE Standard 15. A new equipment room or fire proof division would be required. In a second mechanical room(MR#2) in the lower floor, the compressors while almost 25 years old, look in fair-good condition. These are 40 hp Chrysler R-22 radial compressors and could be potentially salvaged. The 15 hp Carrier air cooled condensers for these compressors are outside. One of them has fallen over from the 1989 Loma Prieta earthquake and is now unusable.'The other could potentially be salvaged tAt the south end of the building, two propeller wall exhaust fans appear to be fair shape, and could be potentially salvaged Outside fuel oil tank has been inventoried by the Corps of Engineers for removal and clean-up. Electric heaters are installed in the nuclear fallout shelter adjacent to the building. A hand pump for cold water to a well or small cistern is broken. PLUMBING There is only one bathroom in the entire building,containing 2 water closets and 1 lavatory which are in disrepair. Stalls are vandalized. Domestic hot water was provided via an electric water heater in MR 1 and an oil fired heater in MR 2. Both heaters are in unserviceable condition. The building sewer exits to a manhole, across the street and finally and eventually winds up in a concrete septic tank. The roof has a rain water collection system incorporating copper gutters to collect water into an underground concrete cistern. A vertical turbine 7.5 hp sobcBioo SALAS O'BRIEN ENGINEERS, INC. 18 I MIDPENINSULA REGIONAL OPEN SPACE DISTRICT 1 MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' um pressurizes a spray nozzle roof cooling system. This system h pump P P Y g Y Y as been destroyed by weather and vandalism; about one half of the roof is destroyed by weather. The pump could possibly be used again since the tank is full of water and thus the casing and volute may be in usable condition. It would only be valuable for a similar purpose. ELECTRICAL All power for this building was provided from the power generation building (B-112) at 4160 volts. Two transformer banks at the building stepped the service down to 460 V and 208 V. Main service is routed to a distribution panel with a 1600 Amp, 208 volt capacity and a second feed serves a panel with 400 amp,460 volt capacity. The outside transformers are not secured and have been inventoried by the Corp of Engineers for removal. The main switchboard isolating the transformer services has fallen over due to the earthquake and is heavily damaged. The interior wiring and conduit appears to be in fair condition although all main feeders have been severed Lighting is a mixture of outdated incandescent fixtures and fluorescent fixtures. All have been damaged from both the earthquake or weather elements weakening the fastening systems. Building once had emergency generators or MG sets for computer power, but they have been previously removed. ' Exterior lighting is damaged due to vandalism and weather. Emergency lighting by individual battery/light units and are unserviceable. tOVERALL COMMENTS: SAFETY: Ceiling hung light fixtures are a hazard to anyone who enters the building since the anchoring methods continue to deteriorate. SALVAGE: None, however to reduce landfill/disposal costs fans, pump,condensers compressors could be salvaged by a contractor. FUTURE USE: None. All equipment is unrepairable. An entire new design/installation would be required for building re- use. so193100 SALAS O'BRIEN ENGINEERS, INC. 19 �I MID PENINSULA REGIONAL OPEN SPA CE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION r ---- - S • 's* 1Y � P I� 1 Building 100 - Operations 9335.01\PHOTO.100 20 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY - ' SPECIAL MILITARY PURPOSE BUILDINGS ' Building 102 Radar Tower --; h oil I I • i Building 102 - Radar Tower GENERAL: This 19,845 +/- square foot structure was constructed in 1959. It is a ' five-story cast-in-place concrete structure with concrete floors, roof and interior concrete columns. Windows in the building are limited to restrooms on a few of the floors. Major interior spaces are exposed ' concrete except for minor partitions. The roof previously supported a radar dish. The building was heated by an oil-fired steam boiler system and no air conditioning was provided. Sanitary waste was fed to a ' concrete septic tank. Two electrical transformer banks are located next to the building. ' FIELD OBSERVATIONS: The existing structure appears to agree with the record drawings. The asphalt paving around the building has crack s. 9335.01\BUIIA102.DOC 21 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INNTNTORY AND EVALUATION Major cracks are evident in the exterior walls. Rebar is exposed in some locations. The exterior paint finish is in very poor condition - crackiiiL and peeling on all four exposures. The utility shaft at the southeast comer is filled with \vatcr - appro'%- feet deep. Interior paint, partitions and suspended ceilings are in Marti stateso4' Z - disrepair. Several holes in floors are covered xvith ply'%1,00d. doors have been removed. The roof shows no evidence of major cracking or failure. however. an inspection by a roofing contractor is recommended to determine the integrity of the membrane and flashing. The roof drains are plugaed with vegetation. The steam boiler heating systern is in fair condition. The bathrooms are in poor condition. The electrical equipment is in fair condition. Interior and exterior light fixtures are damaged or unusable. EVALUATION: Restoration of this building is impractical. The repair and maintenance measures would be extensive and are listed below. It may be more practical to abandon the building and restrict it from public access. 9 The building skin requires a considerable amount of patchin(-, an�, refinishing after structural repairs are made. W'indo"vs/giazing and doorsjambs need to be replaced. & Flooring may contain asbestos. It should be inspected anti removed. Concrete floor slabs need to be tested and repaired of cracks. Damaged partitions need to be removed. Damagcd cclinit:s noed to be replaced, 9 Although some of the mechanical equipment is in fair condition. portions have been removed, therefore the system is incomplete.. New equipment must be installed to complete the systLni. Toilet rooms need fixtures. All power was from Building 112. 7 3,',WBUILDIOIDOC GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALITATIWk,' PREVENTIVE MAINTENANCE MEASURES: 9 Secure building entrances. Lock doors tha-, lia,,,,, functionlilL hardware. Board up and make weather tigh-, all oinc- * Remove broken windows and make weather ti,-,ht. e Patch holes in floors and walls. a Remove damaged fil.,,lit fixtures. walls. ceiling, IC'21' L17 remove debris. * Drain cavities that have collected rain water. * Close openings to prevent insect and rodent infestatioli, 9",7,5 01 BUILD102 DOC MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 102 Structural Evaluation Radar Tower BUILDING DESCRIPTION: Five story concrete waffle slab, concrete shearwall building. Interior 3' square concrete columns support waffle slab floors and concrete slab/beam roof. Building rests on concrete mat foundation and Yof concrete fill. 1 EXISTING CONDITIONS: "Classic" diagonal shear crack patterns in all four walls, most significant on the east and west walls. Shear cracking failure at North-East comer with spalling of concrete and rebar exposed. Upper level west wall has horizontal crack near roof and appears to be slightly buckled. 1 PERFORMANCE EVALUATION: Heavy, stiff building has obvious seismic damage to walls. Waffle slabs appear undamaged, as do interior columns. MAINTENANCE EVALUATION: Caulk open wall cracks to mitigate rebar rusting. UPGRADE EVALUATION: Crack repair and repair of East wall with new gunite/concrete wall at lower level. Add strongbacks to tall upper level walls. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1000.00 Upgrade $246000.00 Demolition $ 131000.00 BOLEY CONSULTING ENGINEERS 24 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 102 Mechanical/Electrical Inspection RADAR BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via an oil fired steam boiler. Boiler was P inaccessible for inspection due to the only door into the room being heavily damaged by both vandals and earthquake compression. Steam was piped to several air handlingunits 'u is which ventilated the building. air handling g units are hung on the first floor ceiling,2nd floor(2 units serve 2nd and 3rd floor) and 5th floor (2 units serve 4th and 5th floor). Units are in fair condition and were originally high quality pieces of equipment. The temperature controls appear to have been non-functional with many parts missing or damaged. All of the units looked like they had the capacity to both heat,cool and ventilate each respective floor. On the first floor mechanical area, two refrigerant compressors have been ' removed, and the remaining piping has been left. Two McQuay air cooled 7.5 hp condensers are on concrete stanchions on the north side of the building and appear to be in fair condition. A 60 fresh water tank on stanchions is also in the first floor MR. Two floor mounted air compressors kept a pressurized charge on the tank to . insure water would get up to the 5th floor. The tank and air compressors appear to be in fair condition. An outside fuel oil tank has been inventoried by the Corps of Engineers for removal and clean-up. ' PLUMBING There are two bathrooms in the building. The first floor has 1 urinal, 1 water closet, 1 lavatory and a janitor sink. The entire room is in obvious disrepair. The 5th floor has the same fixture layout, and has had the windows broken out resulting in heavy water damage over the years. It is not known how Domestic hot water was made because of the access problem to the boiler room. The building sewer exits across the street and eventually winds up in a concrete septic tank. The roof has standard drain and down spout system. Trees are growing out of each drain. ELECTRICAL All power for this building was provided from the power generation it n - bu di B 112 at 41 vo lts.olts. Two transformer banks at the building g ( ) e bu d 1 g stepped the service down to 460 V and 208 V. zobe. i•a 00 SALAS O BRIEN ENGINEERS, INC. `2 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Main service is routed to a Westinghouse distribution panel with a 2500 Amp, 208 volt capacity and a second feed serves a panel with 1000 amp, 460 volt capacity. The outside transformers are not secured and have been inventoried by the Corp of Engineers for removal. Condition of service and transformer station is fair given the age and neglect. Lighting is a mixture of outdated incandescent fixtures and fluorescent fixtures with most fixtures being damaged or unusable. Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: SAFETY: Besides the floor holes, mechanically and electrically there does not appear to be any imminent safety hazard. SALVAGE None, however to reduce landfill/disposal costs fans, condensers and tank could be salvaged by a contractor. FUTURE USE: None. All equipment was designed for a single purpose of specific hvac loads which would never exist again. An entire new design/installation would be required for building re-use. sobe.B100 SALAS O'BRIEN ENGINEERS, INC. 26 i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ryK ". *. � -- -. i t. 1 1 Building 102 - Radar Tower 9335.0 1\PHOTO.102 27 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY - SPECIAL MILITARY PURPOSE BUILDINGS ' Building 105 Fallout Shelter ' s i Building 105 - Fallout Shelter GENERAL: This 1,590 +/- square foot underground building was constructed in 1961. It is a semi-circular, corrugated metal structure covered by r approx. 3 feet of earth with an escape hatch to the surface and connected to Building 100 by stairs. The two end walls are poured concrete. FIELD OBSERVATIONS: ' The concrete walls appear to have some chemical deposits and possible water damage. There are cracks in the interior partitions. The water pump is not operational. The compressors are in fair condition. Electric heaters supplied heat. Emergency generators have been removed. 9335.O1\BUII,DlOS.DOC 28 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' The structure is relatively undamaged. EVALUATION: This building could be designated for non-essential activities such as storage. Maintenance, Repair and Upgrade Measures: it • Damaged partitions should be removed. Damaged doors and hardware should be replaced. • Latrines could be abandoned. Water pump could be abandoned. • Light fixtures should be replaced. Preventive Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. • Clean up and remove debris. 1 j 9335.0I\BUMDI05.DOC 29 GOULD ARCHITECTS C MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' E TI S C ON 2 BUILDING TYPE SUMMARY - SPECIAL MILITARY PURPOSE BUILDINGS Building107 Radar Tower � III .. - � Ym -,.d - at�4vn'alt����1� yy ,,�.',t` .'��, z1•. - i94 T1 _ l h K 15 - Building 107 - Radar Tower GENERAL: o The foundation of the tower is all that remains. EVALUATION: The foundation should be removed and the site regraded. 9335.01\BUILD107.DOC 30 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY - SPECIAL MILITARY PURPOSE BUILDINGS Building 108 Radar Tower 7n I :a Building 108 - Radar Tower t GENERAL: Steel frame radar tower on four footings formingapproximate an PP square of 19 feet x 19 feet, approx. 40 feet tall to the platform, constructed in 1961. Metal stairs provide access. FIELD OBSERVATIONS: The structure appears to be in good condition except for rusting. ' EVALUATION: It is possible that this building could be dismantled and reused by another agency as a fire lookout as was the other radar tower, Building 107. 9335.01\BUILDI08.DOC 31 GOULD ARCHITECTS i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Maintenance,Repair and Upgrade Measures: • Remove rust and paint. • Stair and platform guardrails shall be modified to meet current codes. 1 � ' 9335.0MBUILD108.DOC 32 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 108 Structural Evaluation Radar Tower BUILDING DESCRIPTION: Steel frame tower structure with bolted connections and steel angle wind bracing. Steel columns anchored to concrete pier footings. E)USTING CONDITIONS: Some rust on connections and steel members. Stair tower lacks bracing in one direction. PERFORMANCE EVALUATION: Lightweight steel frame structre should perform well to resist wind and seismic loads. MAINTENANCE EVALUATION: Paint steel and check bolt tightness. UPGRADE EVALUATION: Add bracing to stair tower. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 5000.00 Demolition $ 10000.00 BOLEY CONSULTING ENGINEERS 33 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SPECIAL MILITARY PURPOSE BUILDINGS Facifitv 103 Helico ter Landin Pad VA ,r SLAM t ..- �...r.. ' Facility 103 - Helicopter Landing Pad ' GENERAL DESCRIPTION: This is a concrete slab approximately 50 feet in diameter. FIELD OBSERVATIONS: a number of projecting footings and curbs. The footings The slab has numb p o� g g g ' appear to have been designed for one of the steel towers. The projections are tripping hazards. EVALUATION: Maintenance,Repair and Upgrade Measures: • The landing pad and foundations should be removed. 9335.01\BUILD103.DOC 34 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SPECIAL MILITARY PURPOSE BUILDINGS Building 106 Wind Measuring Set y x j a ii "' � ,lam'• � Q.x`r yj' ''� '.'�.�Y T'ir /k '�,'_ "f r_-.:>,��11' _ ifs > � '- i�,#,y�• 5'� .i •i�, f+•- _ ! ors ���� t s Via, „ ,#t yE'• ' S dy -af {,l�' !r•.,y� .i - �'�-'�� I r A f ' y,_ ".. xy_b�+�"'� M� .j. Jam,,��•�i } 4 s..^ER�J1 a�r/f!i/�+^-'+�1'-.. 1 Building 106 - Wind Measuring Set GENERAL DESCRIPTION: Only small concrete base remains. FIELD OBSERVATIONS: ' No significance. EVALUATION: Maintenance, Repair and Upgrade Measures: • Remove concrete base and regrade. ' 9335.01\BUILD106.DOC 35 GOULD ARCHITECTS 1 SECTION 2 BUILDING TYPE SUMMARY - ' SPECIAL MILITARY PURPOSE BUILDINGS Building 110 Training Building jump Building 110 -Training Building GENERAL: +/- pre-engineered This 1,080 square foot p e engineered metal building was ' constructed in 1956. It is a one-story corrugated metal (siding and roof) building (Butler Mfg. Co.) on a concrete slab on grade. It was heated and ventilated,but no air conditioning. FIELD OBSERVATIONS: ' The exterior skin is generally in good condition except for minor dents, pencil size holes and rust at the roof ventilators. Some windows are broken and boarded over. Door at southeast corner is in poor ' condition. Water stains (damage) are evident at ceilings, windows and interior ' partitions. Ceiling at southeast porch is collapsing. Floor tile is broken and crumbling. ' 9335.01\BUILD110.DOC 36 GOULD ARCHITECTS 1 Heating equipment has been removed. There is no water to the ' building. Electrical outlets are not grounded. Light fixtures are damaged. tEVALUATION: Maintenance, Repair and Upgrade Measures: • The exterior of the building is in good condition. Minor repairs, painting and recaulking should be done. Broken windows and one door should be relaced. Damaged flooring and drywall partitions should be replaced. Rust spots should be removed. • Damaged light fixtures should be replaced. Electrical outlets should be grounded. A new transformer should be installed. • New heating and ventilating equipment should be installed. • Building anchorage to foundation and longitudinal bracing should be reinforced. rPreventive Maintenance Measures: 1 • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. • Close openings to prevent insect and rodent infestation. • Remove broken windows and make weather tight. 9335.01\BMD110.DM 37 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 110 Structural Evaluation Traning Building BUILDING DESCRIPTION: "Butler" building;prefab. steel frame bents supporting metal deck roof and walls. Rod X bracing in the roof plane braces the building laterally. Concrete spread and continuous perimeter footings and slab on grade floor. EXISTING CONDITIONS: Some buckling of wall siding, otherwise in fair condition. Anchorage to foundation and longitudinal bracing not visible, but no signs of seismic damage either. PERFORMANCE EVALUATION: Relatively lightweight building should perform well seismically. MAINTENANCE EVALUATION: Paint rusted spots on siding and roof. UPGRADE EVALUATION: Verify anchorage to foundation and longitudinal bracing. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1500.00 Upgrade $ 00.00 Demolition $ 5500.00 BOLEY CONSULTING ENGINEERS 38 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' Building 110 Mechanical/Electrical Inspection TRAINING B UILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via an oil fired heating and ventilating which has since been removed. Ceiling hung ductwork still remains and is still usable. Two exhaust fans are still on the roof. There was no air conditioning available to this building. An outside fuel oil tank has been inventoried by the Corps of Engineers for removal and clean-up. PLUMBING There was no bathroom in the building, and hence no hot, cold water or sewer. Storm sewer out in front of the building has probably been affected j by the earthquake since the ground has fractured about 8" across the catch basin entrance. ELECTRICAL All power for this building was provided from the power generation building (B-112) at 4160 volts. One transformer bank at the building stepped the service down to 208 V. Main service is muted to a distribution panel with a 100 Amp, 208 volt capacity. The building outlets are not grounded. The outside transformers 1 are not secured an n d have been inventoried by the Corp of Engineers for removal. Lighting is fluorescent. All have been damaged from both the earthquake or vandals. Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: LSAFETY: Damaged light fixtures are thrown on floor. SALVAGE: None. FUTURE USE: None. All equipment is unrepairable. An entire new design/installation would be required for building re- use. wbe.BI10 SALAS O'BRIEN ENGINEERS, INC. ' 39 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT i MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 I S 1 1 Building 110 - Training Building 93 "O"PHOT0.110 40 GOULD ARCHITECTS ■ SECTION 2 BUILDING TYPE SUMMARY - ■ SPECIAL MILITARY PURPOSE BUILDINGS Building 112 Electrical Power Station 'ITV 1 IIIIII I 'I II, ' Building 112 - Electrical Power Station GENERAL: 1 This is a 5,660 +/- g square foot building of unknown construction date. q 1 It has a concrete masonry base with steel frame and corrugated cement- asbestos board(assumed) siding and a metal roof. The floor is a concrete slab on grade with a number of depressed equipment wells with metal grate walking surfaces. The interior walls and ceiling are exposed framing. The roof was not accessible. The building had no heating and air conditioning. Electrical power was provided by ' generators. FIELD OBSERVATIONS: ' The existing conditions appear to agree with the record drawings. The exterior of the building and surrounding site is in fair condition. The exterior paint finish is peeling at walls and trim. ' 9335.01\BUU D112.DOC 41 GOULD ARCHITECTS i Exterior louvers are deformed. Gutters appear to be intact with the exception of a few missing sections. Not able to determine if they leak. Some downspouts are missing. Exhaust manifolds are rusted (outside surface). Unable to determine extent of rust inside the manifolds. Interior paint finish is peeling. Interior structural framing shows evidence of rusting at connections. Paint at toilet rooms is peeling badly. Generally, the interior is in good condition. Structural system should .perform well seismically. Y LEVALUATION: Maintenance, Repair and Upgrade Measures: • Water damaged drywall should be replaced. Rust from the structure should be removed and repainted. • Louvers, missing gutters and downspouts should be replaced. • Broken windows should be replaced. « Damaged light fixtures. • Diesel generators if inoperable should be repaired abandon or replaced.. • Building should be strengthened with lateral bracing. Preventive Maintenance Measures: ' • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. 9335.01\BUILD I 12.DOC 42 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT, UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 112 Structural Evaluation Electrical Power Station BUILDING DESCRIPTION: Single story energy plant building. Steel frame bents support a high bay central roof of metal deck. Low side structures are of CMU walls and metal deck roof. Rod 'X' braces in the roof and walls provide lateral bracing. Concrete floors have deep pits around generator bases. EXISTING CONDITIONS: Exterior skin corrugated panels appear to be of cement asbestos materials. The wall and low roof rod `X' bracing appears to be minimal. Some cracking of the CMU walls was noted. PERFORMANCE EVALUATION: ' Structural steel frame building should perform well seismically, with some reservation about the wall and low roof bracing in the longitudinal direction. MAINTENANCE EVALUATION: Paint rusted spots on siding and roof. UPGRADE EVALUATION: Strengthen lateral bracing of longitudinal walls and low roof with additional rod or steel angle'X'bracing. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance ainte ante 3000.00 Upgrade $ 25000.00 Demolition $ 26000.00 BOLEY CONSULTING ENGINEERS 43 MIDPENI NSULA REGIONAL OPEN SPACE DISTRIC T MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 112 Mechanical/Electrical Inspection ELECTRICAL POWER PLANT BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was not needed in this building due to the excessive heat generation by the four oil fired, turbo charged, water cooled diesel (Northberg) engine generators. Two exhaust fans are still on the roof. There was no air conditioning available a able to this building. ' Outside fuel oil tanks (two 84,000 gallon above ground, one 20,000 gallon and one 10,000 gallon underground) have been inventoried by the Corps of Engineers for removal and clean-up. Individual engine 275 gallon day tanks inside the building are also inventoried. PLUMBING There was one bathroom in the building, with one water closet and a slop sink. Hot water was provided by an electric 20 gallon unit. ' ELECTRICAL All power for this building was provided from the four diesel 820 KW generators. Three of the generators ran in excess of 73,000 hours, while#4 developed problems after 1500 hours and was used as a parts warehouse for the other machines. Air cooled water radiators serve oil coolers and jacket water are mounted in an equipment area to the west of the building. This equipment looks to be in fair condition considering the age and neglect. All of these machines are inventoried by the Corp for special removals. The generator sections and about 1/2 of the switch gear have been meticulously wrapped in vapor barrier paper to prevent dust,insects/rodents and moisture from entering the windings. Lighting is fluorescent. All have been damaged from both the earthquake or ' vandals. Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: SAFETY: Some damaged light fixtures are thrown on floor. SALVAGE: None, however to reduce landfill/disposal costs engines, generators, silencers, oil inlet filters, heat exchangers could be salvaged by a contractor. sobe.B100 SALAS O'BRIEN ENGINEERS, INC. MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 FUTURE USE: Since this type of load and use is unforeseaable it would require a search of user needs/requirements to find a proper match. An entire new design/installation would be required for building re-use. i so� I i i 1 1 1 1 1 Bioo SALAS O'BRIEN ENGINEERS, INC. 5 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 2 Building 112 - Electrical Power Station 9335-01\PHOTO.112 46 GOULD ARCHITECTS i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' IN SECTION 2 BUILDING TYPE SUMMARY SPECIAL MILITARY PURPOSE BUILDINGS ' Building 114 Sheet & Pipe Storage . ' .. 1 1 Building 114 - Sheet& Pipe Storage GENERAL DESCRIPTION: ! This is a 40 +/- square foot concrete masonry building of unknown 9 m'Y g construction date. It is built on a concrete slab on grade. A small metal cabinet is attached at one end. FIELD OBSERVATIONS: No problems with this building where observed. ! EVALUATION: ' Maintenance,Repair and Upgrade Measures: ' • Building should be painted. • Door and hardware should be replaced. ! 9335.01\BUIIAI I4.DOC 47 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 114 Structural Evalution ' Sheet & Pipe Storage BUILDING DESCRIPTION: Small CMU wall structure with wood roof. Storage building. EXISTING CONDITIONS: No distress noted. ' PERFORMANCE EVALUATION: MAINTENANCE EVALUATION: None. UPGRADE EVALUATION: ' None. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 00.00 Upgrade $ 00.00 Demolition $ 1000.00 BOLEY CONSULTING ENGINEERS 48 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SPECIAL MILITARY PURPOSE BUILDINGS ' Building 115 Gate House � I �i{ate .may ' Building 115 - Gate House GENERAL DESCRIPTION: ' + - 1 building of unknown This Is a 215 / square foot metal cad bu 1 g construction date. The walls and shed roof are corrugated metal. It is built on a concrete slab on grade. The building was heated, no air conditioning. Main electrical service is from Building 112.. ' FIELD OBSERVATIONS: Windows are broken allowing rain intrusion. Substantial water damage to ceilings, walls and floors. ' Concrete slab is undermined at one corner. ' Heating and lighting are in very poor condition. 9335.01\BUILD115.DOC 49 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' EVALUATION: This building is functionally obsolete. It has no potential or salvage opportunity. It should be demolished. Preventative Maintenance Measures: ' • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. ' • Remove broken windows and make weather tight. ' • Shore up undetermined foundations. Install barricades/fences around these areas. ' • Remove damaged light fixtures, walls, ceiling finishes, etc., clean up and remove debris. ' • Close openings to prevent insect and rodent infestation. I i, 1 .t a 1 � ' 9335.01\13UQ D115.DOC 50 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY SPECIAL MILITARY PURPOSE BUILDINGS ' Building 117 Diesel Fuel Pump Station 1 _ . s 1 �• A !M I _ y 1 ' Building 117 - Diesel Fuel Pump Station GENERAL DESCRIPTION: This 1s a 250 /- square foot concrete masonry building of unknown construction date. It is built on a concrete slab on grade and a built-up ' shed roof The building was ventilated only. Main electrical service is from Building 112. ' FIELD OBSERVATIONS: ' The building is in good condition. Exterior paint is peeling. Windows are broken. Doors are rusting. No visible signs of water damage inside. Chemical stains on interior surfaces of masonry walls. ' Possible valve leak at one of the pumps. 9335.0 111111 1 7.DOC 52 GOULD ARCHITECTS f MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: Unless diesel fuel will be used on site and fuel lines and pumps are ' operational, the building is obsolete and should be abandoned or demolished. ' Maintenance,Repair and Upgrade Measures: • Broken windows should be replaced. Rust from doors should be ' replaced and painted. • Building should be painted. Masonrysurfaces should be treated and painted. ' • Pumps should be serviced. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. ' • Close o enin s to revent insect and rodent infestation. ' 9335.01\BUILDII7.DOC 53 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 117 & Building 118 Structural Evaluation Diesel Fuel Pump House BUILDING DESCRIPTION: ' CMU wall building with concrete roof. Contains concrete slab floor and concrete pads for pumps. I EXISTING CONDITIONS: No damage noted. PERFORMANCE EVALUATION: Simple small box structure. ' MAINTENANCE EVALUATION: None. UPGRADE EVALUATION: None. ' ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 00.00 ' Upgrade $ 00.00 Demolition $ 4000.00 BOLEY CONSULTING ENGINEERS ' 54 MIDP NINSUL E ARE REGIONAL G OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' Building 118 Mechanical/Electrical Inspection ' DIESEL FUEL PUMP MAINT. BUILDING HEATING, VENTILATING & AIR CONDITIONING ' SYSTEMS: There is no building heat. An exhaust fan near the ceiling vents the space and is in very poor condition. There is no air conditioning. Three Hubbard base mounted centrifugal diesel oil pumps used for fuel transfer and outside station piping system pressurization are still in fair to good condition. PLUMBING ' There is no plumbing in the building. ELECTRICAL ' All power for this building was provided from the power generation building (B-112) at 4160 volts. A pole mounted transformer banks at the ' building step the service down to 208 V. Main service is routed to a distribution panel with a 100 Amp, 208 volt capacity . Lighting is fluorescent and is good condition. ' OVERALL COMMENTS: SAFETY: None. SALVAGE: None, however to reduce landfill/disposal costs pumps could be salvaged by a contractor. ' FUTURE USE: None. r ' .obe:BI18 SALAS O'BRIEN ENGINEERS, INC. 55 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY - SPECIAL MILITARY PURPOSE BUILDINGS ' Building 119 CE Maintenance Shop 01 { Building 119 - CE Maintenance Shop GENERAL: This is a 1920 +/- square foot pre-engineered metal building of q p g g ' unknown construction date. It is a one-story corrugated metal (siding and roof) building on a concrete slab on grade. It was heated and ventilated, but no air-conditioned. ' FIELD OBSERVATIONS: The existing structure appears to agree with the Record Documents. The shell appears to be site-constructed, steel frame with corrugated metal skin. The building is in poor condition. Roof vents are missing allowing rain intrusion. Rust is evident throughout the exterior, at the roof overhangs and siding fasteners. ' Windows are broken and paint is peeling. Doors are deteriorating or missing. A portion of the roof is missing over the toilet room. ' 9335.01\BMD119.DOC 56 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Rain has caused significant damage to floors, ceilings and walls ' throughout. The building was heated by an oil-fired heating and ventilating furnace. No air conditioning. Exhaust fans are in very poor condition. Toilet room is in very P very poor condition. Water heater is in ve poor condition. Light fixtures have been damaged. EVALUATION: Maintenance,Repair and Upgrade Measures: • Rust from siding and roof should be removed and painted • Doors should be replaced. ' • Floor finishes dama ged walls and ceilings should be replaced. ' • Hole in roof above toilet room should be repaired. • Remove and replace light fixtures. Connections are hazardous. • Hating and ventilating equipment, water heater, toilet fixtures should be replaced • Fundation connections and bracing should be reinforced. Preventive Maintenance Measures: ' • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. • Close openings to prevent insect and rodent infestation. • Remove broken windows and make weather tight. • Clean up and remove debris. 9335.01\BUU Dt 19.DOC 57 GOULD ARCHITECTS I I MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION I, , Building 119 Structural Evaluation CE Maintenance Shop BUILDING DESCRIPTION: Prefab. metal building; steel frame bents support corrugated metal roof and walls. Rod X bracing in the root at end bays only. Concrete slab on grade floor and perimeter foundation. EXISTING CONDITIONS: Hole in roof at North-West comer. Anchorage to foundation and longitudinal wall bracing not visible. Some rust on roof and wall panels. PERFORMANCE EVALUATION: Lightweight steel building should perform well seismically. MARTMNANCE EVALUATION: Fix roof hole, paint root walls for rust protection. UPGRADE EVALUATION: Verify foundation connections and longitudinal bracing. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 00.00 Demolition $ 11500.00 II BOLEY CONSULTING ENGINEERS 58 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 119 CE Maintenance Shop MATERIAL CONTROL BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via an oil fired Rossaire heating and ventilating furnace. Fuel oil piping from the underground piping system fed the two heaters. Ceiling ductwork and register are still in place. There is no air conditioning. There is an exhaust fan mounted on the roof which appears in very poor condition PLUMBING ' _ There is one bathroom, one water closet, one lavatory and a janitor sink Stalls are vandalized. Domestic hot water was made via an 30 gallon electric hot water heater and it appears to be in poor condition. ELECTRICAL Main service is routed to a distribution panel with a 50 Amp, 208 volt capacity, and is fed from the underground distribution system. Lighting is a mixture of outdated incandescent fixtures and fluorescent fixtures. All have been damaged from both the earthquake or weather elements weakening the fastening systems. Exterior lighting is damaged due to vandalism and weather. Emergency lighting by individual battery/light units and are unserviceable. OVERALL COMMENTS: SAFETY: Ceiling hung light fixtures are a hazard to anyone who enters the building since the anchoring methods continue to deteriorate. The communication cable on the adjacent power poles has poor attachment and is sagging badly. Continued weathering will force all of this wire to the ground. SALVAGE: None. FUTURE USE: None. All equipment is unrepairable. An entire new design/installation would be required for building re- use. sobc:B 119 SALAS O'BRIEN ENGINEERS, INC. 59 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION I - a Ii i 3 - Building 119 - CE Maintenance Shop 9335.01THOTOA 19 60 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY - ' SPECIAL MILITARY PURPOSE BUILDINGS ' Building 120 Warehouse Supply and Equipment 1 f _ ,tea► - r ..•-,r—'.^�.w« '-'�� �s+•�c ter« �".it .s �� Building 120 - Warehouse Supply and Equipment GENERAL DESCRIPTION: This 2,190 +/- square foot concrete masonry building was built in q �' g ' 1957. The floor is a concrete slab on grade. The roof is shed-style built-up roof. It was provided with ducted heating and ventilation but no air conditioning. Main electrical services is from Building 112. FIELD OBSERVATIONS: ' The concrete masonry shell is in good condition. Metal gutters are in reasonably good condition except for northeast corner which is leaking. A number of windows are leaking. Extensive water damage inside the building presumably through broken windows. ' T-bar ceiling is severely damaged. Panels are missing and grid is rusting. Paint is peeling. 9335.01\BUQ.D120.DOC 61 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Storage shelves have collapsed. Plumbing is in poor condition. Cold water tank is identified for removal. Lighting is in very poor condition. EVALUATION: The restoration of this building is economically impractical. The repair, maintenance and upgrade measures are extensive and are listed as follows: * Due to the age of this building, the composition of the floor the could include asbestos. Further investigation by a hazardous materials expert is recommended. * Holes in roof should be patched. 9 Broken windows should be replaced. 9 Flooring,damaged partitions and ceilings should be replaced. e All mechanical and electrical equipment is unrepairable. Fuel oil tanks are identified for removal. Cold water tank is identified for removal. Toilet room fixtures and light fixtures need to be replaced. 9 Masonry infill should be inspected and anchor ties to existing structure should be installed. Preventive Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. * Close openings to prevent insect and rodent infestation. • Remove broken windows and make weather tight. 9335.01\13MLD12O.DOC 62 GOULD ARCHITECTS NIIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 120 Structural Evaluation Warehouse Supply & Equipment BUILDING DESCRIPTION: Single story CMU wall building with steel truss and metal deck roof. Central structure is high bay with clerestory windows. Low bay side structures have CMU walls and concrete roof. EXISTING CONDITIONS: CMU walls contain little cracking. Paint on roof deck and joists is deteriorated. Several window/door infdls exist. PERFORMANCE EVALUATION: Building has held up well to seismic forces. MAINTENANCE EVALUATION: None. UPGRADE EVALUATION: Verify CMU infills are anchored to walls. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 00.00 Upgrade $ 24000.00 Demolition $ 25000.00 BOLEY CONSULTING ENGINEERS 63 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 120 Mechanical/Electrical Inspection WAREHOUSE SUPPLY BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via an oil fired Rossaire heating and ventilating unit with ceiling ductwork. One units is located in an adjacent welding shop and ducted over to the building. There was no air conditioning. There are two underground fuel oil tank has been inventoried by the Corps of Engineers for removal and clean-up. There are two level-o-meters with an outline of three others on the wall,but have been removed. There is also a 500 gallon above ground tank behind the building which is not secured There is no oil inside it. PLUMBING There is one bathroom in the building with one water closet and one lavatory which are in poor condition. Domestic hot water was made via a 20 gallon Lochinvar electric hot water heater located in a hallway enclosure. The copper roof gutters are in fair to good condition. A 4'0 x 19 high domestic cold water tank is located in a small g mechanical room. A small tank mounted reciprocating air compressor appears to be in good condition and has been tagged by the Corps. ELECTRICAL Power for this building was provided from the power generation building (B-112)at 4160 volts. Main service is routed to a distribution panel with a 225 Amp,208 volt capacity and a second feed serves a panel with 50 amp,208V volt capacity in the welding shop annex. The interior wiring and conduit appears to be in fair condition. Lighting is fluorescent which are in very poor condition. All have been damaged from both the earthquake or weather elements weakening the fastening systems. Exterior lighting is damaged due to vandalism and weather. i� SALAS O'BRIEN ENGINEERS, INC. 64 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHU M FACILITIES INVENTORY AND EVALUATION OVERALL COMMENTS: SAFETY: Ceiling hung light fixtures are a hazard to anyone who enters the building since the anchoring methods continue to deteriorate. SALVAGE: None,however to reduce landfill/disposal costs tank and air compressor could be salvaged by a contractor. FUTURE USE: None. All equipment is unrepairable. An entire new design/mstallation would be required for building re- use. 1 E t sobc.Bl20 SALAS o'BRIEN ENGINEERS, INC. 65 I MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION tit 1 i Building 120 - Warehouse Supply and Equipment 9335.01THOT0.120 66 GOULD ARCHITECTS i i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS Building 200 Water Pump Station 4 1 1 t f� Building 200 - Water Pump Station GENERAL DESCRIPTION: This Is a 240 +/_ square foot pre-engineered metal building of unknown construction date. The walls and gable roof are corrugated ' metal. It is built on a concrete slab on grade. The building was heated. Main electrical service is from Building 112 and PG&E. FIELD OBSERVATIONS: No visible signs of cross bracing. Some water damage to roof insulation. Exterior paint is peeling. 1 Heater is in poor condition. Pump engine is in poor condition. Service head has fallen off of the building and is supported by the wire only. Lighting is in good condition. 9335.01\BUILD200.DOC 67 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: I, Maintenance,Repair and Upgrade Measures: • Roof should be checked for leaks. • Building should be painted. • Concrete cracks should be patched. i • Pump engine should be replaced. • Wall heater should be replaced. • Service head should be reattached. • Cross bracing should be installed. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove damaged light fixtures, wails, ceiling finishes, etc., clean up and remove debris. • Close openings to prevent insect and rodent infestation. 9335.01\BUR D200.DOC 68 GOULD ARCHITECTS MIDP ENIlNStTLA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION i Building 200 Structural Evaluation Water Pump Station BUILDING DESCRIPTION: Small rectangular light gage metal building-metal studwalls and roof with standing seam metal roof and sheet metal siding. Metal strap horizonal bracing at ceiling. Concrete floor pump building. I� EXISTING CONDITIONS: No vertical wall bracing visible. i - PERFORMANCE EVALUATION: Lightweight building, but no bracing exists unless siding is fastened to give minimum lateral stiffness. MAINTENANCE EVALUATION: Patch concrete crack 1 s to slow reinforcement deterioration. UPGRADE EVALUATION: 'X'Brace walls. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 500.00 Upgrade $ 1000.00 Demolition $ 1000.00 1 BOLEY CONSULTING ENGINEERS 69 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 200 Mechanical/Electrical Inspection WATER PUMP STATION BUILDING 1 HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via a wall mounted electric heater and appears to be in poor condition. There was no air conditioning. There appears to be both an underground fuel oil tank since there is a vent above grade. There is also an above grade fuel oil tank for the diesel engine and this tank is not anchored to the ground. There is no oil inside it. PLUMBING There are no bathrooms in the building. A diesel oil engine driven base mounted pump pressurizes the water system for the area above the station. It is also connected to a 30 hp electric motor for redundancy. Engine appears to be in poor condition. Two vertical, 10 hp Johnston turbine pumps serve the fire protection plumbing system. The copper roof gutters are in fair to good condition. ELECTRICAL Power for this building was provided from the power generation building (B-112) at 4160 volts. Several services are muted to a distribution panel from both the overhead and underground system for redundancy. The services appear to be the emergency power circuit and the regular PG&E commercial distribution system. Service head has fallen off the building and is supported by the wire only. The interior wiring and conduit appears to be in fair condition. Lighting is incandescent and is in good condition. OVERALL COMMENTS: SAFETY: The electrical services are supported solely by wire. This is unsafe. SALVAGE: None, however to reduce landfill/disposal costs engine and pumps could be salvaged by a contractor. FUTURE USE: None. All equipment is deemed unrepairable. A,,---B 100 SALAS O'BRIEN ENGINEERS, INC. 70 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 0+7 i ■ a M • s • Building 200 - Water Pump Station 9335.01\PHOTO.200 71 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY - SUPPORT BUILDINGS tBuilding 205 Bachelor Officers' Quarters 1 s 1 Building 205 - Bachelor Officers' Quarters GENERAL DESCRIPTION: This 1,920 +/- square foot pre-engineered metal building was q p g g constructed in approximately 1956. It is built on a raised wood floor. The walls and gabled roof are corrugated metal. The building was heated, ventilated and air-conditioned. Main electrical service is overhead. FIELD OBSERVATIONS: The corrugated metal siding and roof show signs of rusting. Broken windows are boarded over. One door is missing hardware. Foundation at southeast corner appears to be undermined and cracked. Extensive water damage throughout to ceilings, walls and floors. Longitudinal bracing not visible. 9335.01\BW D205.DOC 72 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Plumbing is in fair to poor condition. EVALUATION: Maintenance,Repair and Upgrade Measures: e Rust should be removed and painted. Broken windows and doors should be replaced. 9 Damaged flooring,partitions and ceilings should be replaced. 9 Heating and ventilating systems should be replaced. Air conditioning equipment should be replaced. Plumbing fixtures and light fixtures should be replaced. 9 Under-floor lateral bracing should be installed. Preventive Maintenance Measures: * Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. 9 Remove broken windows and make weather tight. * Patch concrete cracks to slow rusting of reinforced steel. �, ' e Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. e Close openings to prevent insect and rodent infestation. 9335.01\BUMD205DOC 73 GOULD ARCHITECTS MIDPENINSULA RE GIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 205 Structural Evaluation Bachelor Officers' Quarters BUILDING DESCRIPTION: Prefabricated-steel frame building on concrete grade beam and pier/column foundations. Steel bents in the transverse direction and rod'X'bracing in the roof provide lateral bracing. Roof and walls are corrugated metal. Floor is plywood over wood joists supported by a concrete perimeter grade beam and pier foundation. EXISTING CONDITIONS: Cracking of grade beam/pier-column joint was noted at the South/West corner of the building. Longitudinal bracing is not visible in the metal building. PERFORMANCE EVALUATION: Lightweight steel frame building should perform well. Concrete beam/column raised foundation shows some distress at the beam-column joints. MAINTENANCE EVALUATION: Paint rusted spots on siding and roof; patch concrete cracks to slow rusting of reinforcing steel. III UPGRADE EVALUATION: Verify longitudinal bracing in the metal building. Provide under floor lateral bracing or verify concrete beam/column foundation capacity to resist lateral loads. ESTIMATE OF PROBABLE CONSTRUCTION G ON COST: Maintenance $ 2600.00 Upgrade $ 7000.00 Demolition $16500.00 BOLEY CONSULTING ENGINEERS 74 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 205 Mechanical/Electrical Inspection BOQ BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via two oil fired Rossaire heating and ventilating units and are in poor condition. There is a 500 gallon above ground tank behind the building which is not secured. There is no oil inside it. There is a swamp cooler mounted on the west wall for air conditioning and this is in poor condition. There is also a Chrysler window A/C unit which appears in poor condition. PLUMBING r - There are two bathrooms in the building. One has one water closet, one shower and one lavatory which is in poor condition. The other has a tub, water closet and lav and is in fair condition. Domestic hot water was made via a 40 gallon electric hot water heater. The kitchen has an electric range,refrigerator and sink. ELECTRICAL Main service is routed overhead from the pole to a distribution panel with a 100 Amp, 120/240 volt capacity. The interior wiring and conduit appears to be in fair condition. III , Lighting is mostly fluorescent and is in very poor condition. There is some equipment in a comer office used by the Civil Air patrol, but this was inaccessible. Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: 1 SAFETY: None SALVAGE: None. FUTURE USE: None. All equipment is unrepairable. An entire new design/installation would be required for building re- use. sobe—B100 SALAS O'BRIEN ENGINEERS, INC. 75 r MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 1 ' N r 0 ti r , 4 - r a k k r r . l r 1. 1 g r Building 205 - Bachelor Officers' Quarters r 9335.01THOTO.205 76 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS ' Building 207 Headquarters Squadron r ' 116 ' Building 207 - Headquarters Squadron GENERAL DESCRIPTION: ' This 1,920 +/- square foot pre-engineered metal building is very q P g g similar to Building 205. It is built on a raised wood floor. The walls ' and gabled roof are corrugated metal. The building was heated, ventilated, and air-conditioned. Main electrical service is overhead. FIELD OBSERVATIONS: ' The corrugated metal siding and roof show signs of rusting. Windows are in need of refinishing. Some damage to suspended ceiling grids. Ceiling panels are warped and stained. Some water damage to floor tiles. Cracks in partitions. Crack in floor along construction joint. Large crack in foundation. 9335.01\BUILD207.DOC 77 COULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: Maintenance,Repair and Upgrade Measures: • Refer to comments for Building 205. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Repair or replace damaged or missing guardrails. • Shore up undetermined foundations. Install barricades/fences around these areas. ' • Patch holes in floors and walls. • Remove damaged light fixtures, walls, ceiling finishes, etc., clean up and remove debris. • Remove collapsed structures such ad decks, fire hose houses, etc. • Drain cavities that have collected rain water. Close openings to prevent insect and rodent infestation. • Install temporary' retainng wal ls, netting, etc. to prev ent further soil erosion. 9335.011BURD209SOC 78 GOULD ARCHITECTS l AMPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 207 Structural Evaluation Headquarters Squadron BUILDING DESCRIPTION: Prefab. steel frame building on concrete grade beam and pier/column foundations. Steel bents in the transverse direction and rod X bracing in the roof provide lateral bracing. Roof and walls are corrugated metal. Floor is plywood over wood joists supported by a concrete perimeter grade beam and pier foundation. EXISTING CONDITIONS: Cracks at grade beam column joints and past patching indicates inherent lateral weakness. Large crack in foundation beam/wall at South/East comer. PERFORMANCE EVALUATION: Lightweight steel frame building should perform well. Concrete beam/column raised foundation shows some distress at the beam-column joints. Below floor foundation system is system weakness from seismic viewpoint. MAINTENANCE EVALUATION: Patch concrete cracks which have not yet been patched. UPGRADE EVALUATION: Brace underfloor system, verify longitudinal upper building bracing and connection to foundation. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2600.00 Upgrade $ 7000.00 Demolition $16500.00 BOLEY CONSULTING ENGINEERS 79 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 207 Mechanical/Electrical Inspection HQ SQUADRON BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via two oil fired Rossaire heating and ventilating units and are in very poor condition. There is electric baseboard heater in the comer office which is used by the station Ranger. There are two Chrysler window A/C units which appear to be poor condition. PLUMBING There is one bathroom in the building with one water closet,one urinal,one lavatory and a janitor sink which is in poor condition. There is also an electric water cooler on the wall near the bathroom. Domestic hot water was made via a 40 gallon electric hot water heater. ELECTRICAL Main service is routed overhead from a pole to a distribution panel with a 100 Amp, 120/240 volt capacity. The interior wiring and conduit appears to be in fair condition. There is a 60 amp fused disconnect which feeds an ancillary building down the hill and is "on." Lighting is fluorescent and is in very poor condition. Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: SAFETY: None. SALVAGE: None. FUTURE USE: None. All equipment is unrepairable. An entire new design/installation would be required for building re- use. sobe-ZW7 SALAS O'BRIEN ENGINEERS, INC. 80 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION -T= I Building 207 - Headquarters Squadron 9335.01\PHOTO.207 81 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS Building 211 Auto Maintenance Shop }F 3 CM #� ' Building 211 -Auto Maintenance Shop GENERAL DESCRIPTION: ' This 1,984 +/- square foot pre-engineered metal building was q p g g ' constructed in 1956. It is built on a concrete slab on grade. The walls and gable roof are corrugated metal. The building was heated and ventilated, no air-conditioning. Main electrical service is overhead. FIELD OBSERVATIONS: ' The corrugated metal siding and roof show signs of rusting. Several dents are located around the overhead doors. Gutters are rusting and sections of down spouts are missing. Structural bracing appears to be marginal. No bracing on front wall. ' Plumbing is in poor condition. ' 9335.01TUH-D211.DOC 82 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: Maintenance,Repair and Upgrade Measures: • Rust and dents should be removed and metal siding refinished. • Holes in roof should be repaired. Gutters and down spouts should be replaired. • Heating and ventilating systems should be replaced. Plumbing fixtures and exterior light fixtures should be replaced. • Lateral bracing should be upgraded. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. • Close openings to prevent insect and rodent infestation. 9335.011BUnD211DOC 83 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 211 Structural Evaluation rBUILDING DESCRIPTION: Steel frame building with steel bents supporting metal roof ' and corrugated metal siding. Rod'X'bracing occurs in the roof, at the back wall, and at the end walls. Concrete slab floor and foundations. EXISTING CONDITIONS: Some rust on the roof and wall siding. PERFORMANCE EVALUATION: Rod bracing looks minimal and no bracing exists on the front (door)face. MAINTENANCE EVALUATION: ' Paint to slow rust. ' UPGRADE EVALUATION: Upgrade lateral bracing with additional'X'braces or strengthen existing braces. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 8000.00 ' Demolition $ 10000.00 ' 84 BOLEY CONSULTING ENGINEERS 1MIDP NI NSULA REGIONAL OPE N SPACE DISTRI CT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' Building 211 Mechanical/Electrical Inspection MOTOR POOL BUILDING ' HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via two oil fired Rossaire heating and ventilating units and are in very poor condition. There is no air conditioning. Two roof exhaust fans are in very poor condition. A piped/hosed collection system f or engines fumes is sail in place and is connected to a roof exhaust ' fan. Fuel oil is fed from the underground distribution system. There is a small storage area to the north of the building which probably has some ' contamination of the soil. An underground gasoline tank is also nearby with the pump still standing, though its service is highly questionable. ' PLUMBING There is one bathroom in the building with one water closet and one lavatory which is in poor condition. Domestic hot water was made via a 40 ' gallon electric hot water heater and is ready to fall over from its milk carton equipment stand. ELECTRICAL Main service is routed overhead from a pole to a distribution panel with a 100 Amp, 120/208, 30 volt capacity. The interior wiring and conduit appears to be in fair condition. Lighting is incandescent and is in fair condition. Exterior lighting is damaged due to vandalism and weather. g g g OVERALL COMMENTS: SAFETY: Domestic water heater is ready to fall over. There is ' possible soil contamination north of the building as well. SALVAGE: None. ' FUTURE USE: Exhaust fans and heaters could be replaced and the building could still be used as a maintenance facility. sobe:B211 SALAS O'BRIEN ENGINEERS, INC. i 85 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 1 .I I 1 1 Building 211 -Auto Maintenance Shop 9335.01U'HOTO.211 86 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT 1 MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS ' Building 212 NCO Open Mess i I'1,11�,I Ali 1 IIIII I 111 II I. � I � I 1 Building 212 -NCO Open Mess GENERAL DESCRIPTION: This is a 1,950 +/- square foot pre-engineered metal building of q P g g ' unknown construction date. A subsequent 1,690 +/- square feet were added in 1975. An undocumented shed structure and wood deck was added some time later. The walls and gable roof are corrugated metal. ' It is built on a concrete slab on grade. The building was heated, ventilated and air conditioned. Main electrical service is overhead. 1 FIELD OBSERVATIONS: The roof is uplifting at the north doorway, lacking flashing, dents in ' siding, siding is missing at some locations. Substantial water damage to ceilings, walls and floors. 1 Wood deck has major structural damage - partial collapse. ' 9335.01BUILD212.DOC 87 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Plumbing is in poor condition. EVALUATION: This building is in very poor condition although the metal shell is structurally sound. It may be more practical to turn the building over to a salvage contractor. The repair,maintenance and upgrade measures are extensive and are listed as follows: • A considerable amount of the exterior corrugated siding should be replaced. Flashing over doors and at roof-to-wall intersections should be installed. Rust from roof and siding should be removed. Uplifted roof section should be repaired. • Collapsed wood deck should be repaired. 1 * we siding at side addition should be replaced. • Interior finishes(ceiling,walls, floors cabinets) should be replaced. • Plumbing fixtures, water heaters,heating and ventilating systems should be replaced. * Light fixtures should be replaced. • Longitudinal wall bracing should be installed. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceiling finishes, etc., clean up and remove debris. • Remove collapsed deck structure. • Close openings to prevent insect and rodent infestation. � r I', ' 9335.01\BUILD212.E)OC 88 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 212 Structural Evaluation NCO Open Mess BUILDING DESCRIPTION: Prefab. steel ("Butler")building with corrugated metal roof and walls. Steel bents support roof and brace building in the transverse direction. Rod bracing in the end bays of the roof. Concrete slab floor and foundation. EXISTING CONDITIONS: Wood deck off the back of the building is rotted and partially collapsed. PERFORMANCE EVALUATION: Lightweight steel building should perform well seismically. MAINTENANCE EVALUATION: Paint rusted spots on siding and roof. UPGRADE EVALUATION: Verify longitudinal wall bracing and connection to the foundation. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 00.00 Demolition $ 11500.00 BOLEY CONSULTING ENGINEERS � ' 89 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Budding 212 Mechanical/Electrical Inspection ' NCO OPEN MESS BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via two oil fired Rossaire heating and 1 ventilating units and are in very poor condition. A wall mounted air conditioning unit is missing. Two roof exhaust fans are in very poor condition. A piped/hosed collection system for engines fumes is still in place and is connect to a roof exhaust fan. Refrigerated walk-in box is in poor condition. Fuel oil is fed from the underground distribution system. PLUMBING There are two bathrooms in the building. Women's has a water closet and lavatory. The men's has two urinals, a water closet and a lavatory and all are in fair condition. Domestic hot water was made via a 20 and a 40 gallon ' electric hot water heater which appear to be in poor condition. ELECTRICAL ' Main service was routed overhead from a pole to a distribution panel with a 175 Amp, 120/208, 30 volt capacity, but is disconnected. The interior wiring and conduit appears to be in fair condition. ' Lighting is fluorescent and is in poor condition. ' Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: ' SAFETY: None. SALVAGE: None, FUTURE USE: It would need a compete renovation to be used again. sobemloo SALAS O'BRIEN ENGINEERS, INC. 90 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 1 t s� Building 212 -NCO Open Mess 9335.01\PHOTO.212 91 GOULD ARCHITECTS 1 1 I'' MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY ' SUPPORT BUILDINGS ' Building 213 Dispensary ' Building 213- Dispensary GENERAL DESCRIPTION: ' This 1,000 +/- square foot pre-engineered metal building was q p g g constructed in 1956. The walls and gable roof are corrugated metal. It tis built on a concrete slab on grade. The building was heated, ventilated and air conditioned. Main electrical service is overhead. FIELD OBSERVATIONS: ' Down spouts are disconnected. Windows are in.good condition. Substantial water damage to ceilings, walls and floors. All cabinets are in poor condition. Plumbing is in poor condition. ' 9335.01\BUILD213.DOC 92 GOULD ARCHITECTS ' MIDPENINSULA REGIONAL OPEN P S ACE DISTRICT r MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: Maintenance,Repair and Upgrade Measures: • Holes in metal siding should be patched, flashing should be repaired and recaulked. • Down spouts should be repaired. 1 • Damaged ceiling, walls and flooring should be replaced. • Interior wood trim and casework should be repaired. • Water heater should be replaced. - • Main service drop should be reattached and exterior lighting should be replaced. t • Heating and ventilating systems should be repaired. • Longitudinal wall bracing should be installed. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. • Close openings to prevent insect and rodent infestation. ' 9335.01\BUILD213.DOC 93 GOULD ARCHITECTS AIIIDPENI[NSUILA REGIONAL OPEN SPACE DISTRICT MT- UMUNIIUM FACILITIES INVENTORY AND EVALUATION Building 213 Structural Evaluation Dispensary BUILDING DESCRIPTION: Prefab. steel ("Butler")building with corrugated metal roof and walls. Steel bents support roof and brace building in the transverse direction. Rod bracing in the end bays of the roof. Concrete perimeter foundation and wood frame floor. EXISTING CONDITIONS: Some rust on the roof. Longitudinal wall bracing is not visible. PERFORMANCE EVALUATION: Lightweight steel building should perform well seismically. MAINTENANCE EVALUATION: Paint rusted spots on siding and roof. UPGRADE EVALUATION: Verify longitudinal wall bracing and connection to the foundation. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1500.00 Upgrade $ 00.00 Demolition $ 6000.00 BOLEY CONSULTING ENGINEERS 94 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 213 Mechanical/Electrical Inspection DISPENSARY BUILDING HEATING VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via one oil fired Rossaire heating and ventilating unit and is in very fair condition. A wall mounted swamp cooler provided air conditioning. Fuel oil is fed from the underground distribution system. PLUMBING There is one bathroom in the building with a water closet and lavatory. An electric water cooler is mounted on the wall. Domestic hot water was made via a 30 gallon Day n'Night electric hot water heater which appears to be in poor condition. There are two other small lavatories in the doctor's office with hot and cold water. ELECTRICAL Main service is routed overhead from a pole to a distribution panel with a 100 Amp, 120/240, 10 volt capacity. Main service drop is disconnected. The interior wiring and conduit appears to be in fair condition. Lighting is fluorescent and is in fair condition. Exterior lighting is damaged due to vandalism and weather. OVERALL COMMENTS: SAFETY: None. SALVAGE: None. FUTURE USE: It would need a complete renovation to be used again. tobmB213 SALAS O'BRIEN ENGINEERS, INC. 95 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION i ■ 1 Building 213 - Dispensary 9335.011PHOTO.213 96 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS Building 217 Bowling Alley 1 r _ 4 J 'Y. t.\ Building 217 - Bowling Alley GENERAL DESCRIPTION: This is a 1,740 +/- square foot concrete masonry building constructed q m'Y g in 1961. It is built on a concrete slab on grade. It has a flat built-up roof. The building was heated and ventilated, no air conditioning. Main electrical service is overhead. FIELD OBSERVATIONS: There is significant damage to the roof flashing,fascia and roof. Substantial water damage to ceilings, walls and floors. Windows are broken. IPlumbing is in very poor condition. Heating and ventilating equipment is in very poor condition. 9335.01WILD217.DOC 97 GOULD ARCHITECTS i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Lighting fixtures are in very poor condition. There are no structural ties between the roof framing and the masonry walls. EVALUATION: 1 The restoration of this building is impractical. The repair, maintenance and upgrade measures are extensive and are listed as follows: • Due to the age of the building, the composition of the floor the could include asbestos. Further investigation by a hazardous materials expert is recommended. • Holes in the roof should be repaired. • The building skin requires extensive patching and refinishing after structural repairs are made. Windows and doors should be replaced. • Flooring, damaged partitions and ceilings, heating and venilating systems, plumbing systems and fixtures, and light fixtures should be replaced. • Roof diaphragm should be strengthened with additional ceiling plywood. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. • Close openings to prevent insect and rodent infestation. i t9335.0I\BURD217.DOC gg GOULD ARCHITECTS i MIDPENI[NSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 217 Structural Evaluation Bowling Alley BUILDING DESCRIPTION: Long rectangular single story building. CMU walls support wood joist and plywood roof. Concrete slab floor and concrete foundations support the superstructure. EXISTING CONDITIONS: A hole exists in the roof on the west side. No positive ties exist between the roof framing and the CMU walls. PERFORMANCE EVALUATION: The small structure would perform adequately with the addition of wall ties and diaphragm strengthening. MAINTENANCE EVALUATION: Fix hole in the roof UPGRADE EVALUATION: Add roof to wall ties and strengthen roof diaphragm with the additional ceiling plywood. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 4000.00 Upgrade $ 17500.00 Demolition $ 9500.00 1 ' 1 BOLEY CONSULTING ENGINEERS 99 MIDPENINS ULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' Building 217 Mechanical/Electrical Inspection BOWLING ALLEY BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via one oil fired Rossaire heating and ventilating unit and is in very poor condition. An exhaust fan in the 1 bathroom is in very poor condition. An above ground fuel oil tank has been removed. Fuel oil was also fed from the underground distribution system. PLUMBING There are two bathrooms in very poor condition. The women's has with a water closet and lavatory. The men's has a urinal,water closet and lavatory. An electric water cooler is mounted on the wall. Domestic hot 1 water was made via a 30 gallon electric hot water heater which also appears to be in very poor condition. ELECTRICAL Main service is routed overhead from a pole to a distribution panel with a 70 Amp, 120/240, 10 volt capacity. The interior wiring and conduit appears to be in fair condition. Lighting is fluorescent and is in very poor condition with parts of the ceiling falling down. OVERALL COMMENTS: SAFETY: Ceiling panels continue to fall down and present an egress hazard. SALVAGE: None. FUTURE USE: It would need a complete renovation to be used again. P g 50be:3100 SALAS O'BRIEN ENGINEERS, INC. 100 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 � 1 1 1 _ _ - r Building 217 - Bowling Alley r 9335.01\PHOTO.217 101 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS Building 225 Airmen's Dining 1Hall TT ' Building 225 - Airmen's Dining Hall GENERAL DESCRIPTION: This is a 4,640 +/- square foot pre-engineered metal building q P g constructed in 1956. It is built on a concrete slab on grade. The walls and gable roof are corrugated metal. The building was heated and ventilated, no air conditioning. Main electrical service is overhead. FIELD OBSERVATIONS: Daylight is showing through the metal siding at the loading dock section. Substantial water damage to ceilings, walls and floors. Partial collapse of ceiling at Boiler Room. Roof access at loading dock has no roof covering. Plumbing is in poor condition. 9335.01\BUILD225.DOC 102 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: Maintenance,Repair and Upgrade Measures: * Rust spots on siding should be removed and refinished. Siding at loading dock section of building should be replaced. Roof hatch should be installed at roof access. * Damaged floor,partitions and ceilings should be replaced. 9 Holes in roof should be repaired. 9 Heating and ventilating systems, walk-in refrigerator unit compressors, plumbing fixtures and light fixtures should be replaced. * Kitchen hoods should be refurbished. * Longitudinal bracing should be installed. Preventative Maintenance Measures: * Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. e Remove broken windows and make weather tight. 9 Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. * Close openings to prevent insect and rodent infestation. 9335.011BUILD225.DOC 103 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPA CE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 225 Structural Evaluation Airmen's ' Dining Hall BUILDING DESCRIPTION: Tall, prefab. metal ('Butler")building with steel bents in rthe transverse direction and rod'X'bracing in the roof Corrugated metal roof deck and siding enclose the building. Concrete foundations support building and concrete slab on grade floor. EXISTING CONDITIONS: Longitudinal wall bracing not visible. Building structure in relatively sound condition. PERFORMANCE EVALUATION: Lightweight steel frame building is regular in plan and should perform well seismically. MAINTENANCE EVALUATION: ' Paint rusted spots on siding and roof. UPGRADE EVALUATION: Verify longitudinal wall bracing and attachment of building to foundations. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 5000.00 Upgrade $ 00.00 IDemolition $ 24000.00 BOLEY CONSULTING ENGINEERS 104 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' Building 225 Mechanical/Electrical Inspection DINING HALL - AIRMAN BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via one oil fired Burnham steam boiler._ Boiler was not anchored down and appears to be in poor condition. A small condensate return unit collects condensate from the various steam consuming appliances and heating and ventilating units. A Rossaire heating and ventilating unit is located in the dining hall section in a corner closet and is in very poor condition. 1 The kitchen has two ceiling hung heating/ventilatingunits with outside air intakes up through he roof. Steam coils ere fed from the boiler. There are four large stainless steel cooking hoods with associated exhaust fans. Hoods are in good condition. Make-up air for the heating and vent units goes through a rotary wheel evaporative cooler. Mounting and anchorage is not adequate. Roof walkway is completely deteriorated. Fuel oil is fed from the underground distribution system. There are three walk-in boxes for refrigeration and freezing of food. All compressors appear to be in poor condition. The boxes themselves are in fair condition. PLUMBING There is one bathroom in very poor condition with a urinal, water closet and lavatory. An electric water cooler is mounted on the wall. Domestic hot water was made with a steam to water heat exchanger inside a 300 gallon tank. III , Fire protection hose racks are in the dininghall; hoses are missing. g ELECTRICAL ' Main service is route d overhead er ead from a pole#48 to a G.E. distribution panel with a 400 Amp, 120/208, 30 volt capacity. The interior wiring and conduit appears to be in fair condition. One exterior drop conductor is not on the insulator. Electric stoves have been removed. Lighting is fluorescent and is in poor condition. Ceiling in the kitchen is in very poor shape; dining hall ceiling is in poor condition. sob�B100 SALAS O'BRIEN ENGINEERS, INC. 105 i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' OVERALL COMMENTS: SAFETY: Roof mounted equipment could come off its supports if a direct earthquake hit the area. SALVAGE: Stainless steel exhaust hoods have some scrap value. FUTURE USE: It would need a complete renovation to be used again. r 1 sotxaioo SALAS OBRIEN ENGINEERS, INC. 106 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 R AdWpftw 1 1 TAT c� Building 225 - Airmen's Dining Hall 9335-01\PHOTO.225 107 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS ' Building 230 Commissary Wt J�. m Building230 - Commissary �'Y GENERAL DESCRIPTION: This was a 1,000 +/- square foot pre-engineered metal building q P g g constructed in 1956. A subsequent 535 +/- square foot wood-frame, metal siding addition was added in 1967. The walls and gable roof are corrugated metal. The original was built on a concrete slab on grade. The addition has no prepared floor. The original building was heated ' and ventilated, no air conditioning. Main electrical service is overhead. FIELD OBSERVATIONS: The addition to the Commissary Building has no apparent lateral bracing. Some water damage to ceilings, walls and floors. Heating/ventilating ductwork system is of unusual design. 9335.01\BUILD230.DOC 108 GOULD ARCHITECTS ' ' MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNBIUM FACILITIES INVENTORY AND EVALUATION No toilet room facilities. Refrigerated display cases in fair condition. EVALUATION: Maintenance,Repair and Upgrade Measures: e Rust spots should be removed from siding and roof and refinished. * Damaged flooring, partitions, ceiling, heating and ventilating systems, electrical wiring and conduit should be replaced. Main electrical service should be reconnected. 9 Refrigerated display cases are usable e The "addition" structure should be removed. * Longitudinal bracing should be added. Preventative Maintenance Measures: 9 Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. e Remove broken windows and make weather tight. II * Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. * Close openings to prevent insect and rodent infestation. 9335.011B MD230DOC 109 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 230 Structural Evaluation Commissary BUILDING DESCRIPTION: Small prefab. steel frame "Butler" building with lean-to attached. Butler'building has concrete slab on grade floor and perimeter footings. The lean-to is wood framed with metal siding and roof with a dirt floor. EXISTING CONDITIONS: ' Metal roof and siding have rusting. The lean-to has no apparent lateral bracing. PERFORMANCE EVALUATION: The lean-to depends on the Butler'building for lateral support and no evidence of additional (or existing) longitudinal lateral support was observed. Lean-to would be expected to perform poorly. MAINTENANCE EVALUATION: Paint roof and siding to slow rust. UPGRADE EVALUATION: Remove the lean-to and verify'Butler'building longitudinal bracing. ' ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1500.00 Upgrade $ 1500.00 Demolition $ 5500.00 BOLEY CONSULTING ENGINEERS 110 i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' Building 230 Mechanical/Electrical Inspection COMMISSARY BUILDING ' HEATI VENTILATING NG, & AIR CONDITIONING SYSTEMS: Building heating was accomplished via one oil fired a Rossaire heating and ventilating unit which ducts air to the ceiling space. Ductwork ceiling grid ' design is unusual and would need to be completely rehabilitated. Fuel oil is fed from the underground distribution system. Dairy and frozen food display cases are in fair condition. There are two walk-in boxes for refrigeration and freezing of food that were assembled in a shed on the side of the building. These boxes have been removed The Buffalows compressors are still present and appear to be in fair condition. PLUMBING There is cold water to a sink for cleaning but no bathroom facilities noted. ELECTRICAL Main service is routed overhead from a pole to a G.E. distribution panel with a 100 Amp, 120/208, 30 volt capacity. The interior wiring and conduit appears to be in poor condition. Entrance disconnect switch is mounted up-side-down. Service to Annex has been severed. Lighting is fluorescent and is in fair condition. OVERALL COMMENTS: SAFETY: None. SALVAGE: Buffalows refrigeration compressors have some scrap value. FUTURE USE: It would need a complete renovation to be used again. sobe�BIOO SALAS O'BRIEN ENGINEERS, INC. 111 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT 1 MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 1 1 1 . 1 � 4 1 - j a k.: 1 1 Building 230 - Commissary 1 9335.011PHOTO.230 112 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS Building245 Recreation/Multi-Purpose P 441 pz ' Building 245 -Recreation/Multi-Purpose GENERAL DESCRIPTION: This is a 4,660 +/- square foot concrete masonry building constructed in 1957. It is built on a concrete slab on grade. The building was ' heated and ventilated, but not air conditioned. Main electrical service is overhead. FIELD OBSERVATIONS: The concrete masonrywalls and trussed roofs stem are in good Y condition. The exterior paint finish is peeling. ' Considerable damage to hardwood floors in gymnasium. Deteriorating floor tile. Water damage to ceilings. lleating,ventilating system is in poor condition. Plumbing is in poor condition ' 9335.01\BUILD245.DOC 113 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Interior wiring is in poor condition. Lighting is in fair condition. Gymnasium lights are in good condition. EVALUATION: Maintenance,Repair and Upgrade Measures: * Damaged flooring, walls, ceiling, heating boiler, plumbing fixtures and water heater, and interior wiring should be replaced. * Roof to wall ties at masonry walls should be upgraded. Preventative Maintenance Measures: * Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. 9 Remove broken windows and make weather tight. o Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. * Remove collapsed fences and fire hose houses. e Close openings to prevent insect and rodent infestation. 1 9335.01\BUILD245.DOC 114 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 245 Structural Evaluation ' Recreation BUILDING DESCRIPTION: Single story with CMU walls on the interior and the exterior supporting a high bay metal truss and metal deck roof system over the gymnasium. A low roof area wraps around the front of the gymnasium. The floor is a concrete slab on grade. Flat bar bracing is visible in the gymnasium roof area. 1 EXISTING CONDITIONS: CMU walls are generally in good condition and the metal deck roof/metal truss roof framing shows no rust. PERFORMANCE EVALUATION: The building has numerous CMU walls to provide resistance to lateral loads. If the roof structure is well tied to the walls, we would expect the building to perform well seismically. iMAINTENANCE EVALUATION: Misc. painting. UPGRADE EVALUATION: Verify roof to wall ties at the CMU walls. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 20000.00 Demolition $ 28000.00 BOLEY CONSULTING ENGINEERS ' 115 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 245 Mechanical/Electrical Inspection MP RECREATION BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via one oil fired hot water Radiant boiler in a rear mechanical room. Boiler appears to be in poor condition. Heating hot water is circulated around to baseboard heaters in the offices, locker rooms and to heating and ventilating units. Fuel oil is fed from the underground distribution system. PLUMBING There are two bathrooms with lavatory, water closet and shower. The men's bathroom also has a urinal. An electric water cooler has been removed from the wall. Domestic hot water is made with an oil fired 50 gallon heater. This appears to be in poor condition. The swimming pool filter system is in a small shed and appears to be in fair condition. The circulation pump has been removed. The heater is in very poor condition with a bizarre 30 gallon garbage can serving as a flue! ELECTRICAL Main service is routed overhead from a pole 5 or 67 to a G.E. distribution panel with a 100 Amp, 120/208, 30 volt capacity and is in fair/poor condition. The interior wiring and conduit appears to be in poor condition. Lighting in the office and locker room is fluorescent and is in fair condition. The gymnasium lights are incandescent and are in good condition. There is a separate feed to the pool equipment near pole 60 that feed a 60 amp service for pool pump and heater located in a separate adjacent structure. OVERALL COMMENTS: SAFETY: None. SALVAGE: None. ' FUTURE USE: The building would need extensive mechanical and electrical renovation to be used again. wbe:B100 SALAS O'BRIEN ENGINEERS, INC. 116 I MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 1 1 E.k. f l�w ` tr L n' 4 1 1 Building 245 -Recreation/Multi-Purpose 9335.01THOT0.245 117 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS ' Building 250 Auto Maintenance Storage r I � i i "t J ' Building 250 - Auto Maintenance Storage GENERAL DESCRIPTION: ' This is a 360 +/- square foot pre-engineered metal building of unknown construction date. It is built on a concrete slab on grade. The ' building was unheated . Main electrical service is overhead. FIELD OBSERVATIONS: This building does not agree with the record documents. ' No apparent deficiencies except for rust spots on siding. EVALUATION: Maintenance, Repair and Upgrade Measures: • Remove rust spots from siding and refinish. ' 9335.01\BUILD250.DOC 118 GOULD ARCHITEM 1 i MIDPENINSULA REGIONAL OPEN SPACE DISTRICT r MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Preventative Maintenance Measures: 1 • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. ' • Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. ' • Close openings to prevent insect and rodent infestation. 1 1 1 n 1 r � ... Building 250 -Auto Maintenance Storage r9335.01\BUILD250.DOC 119 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 250 Structural Evaluation Auto Maintenance BUILDING DESCRIPTION: Prefab. steel frame 'Butler" building with steel bents at the front and rear walls and rod W bracing on side walls and roof. Metal roof and siding enclose the building. A concrete slab floor/foundation contains wire mesh reinforcement. ' EXISTING CONDITIONS: Some rust exists on the exterior metal roofing and siding. PERFORMANCE EVALUATION: Small lightweight 'Box" building with a complete lateral system should perform well. MAINTENANCE EVALUATION: Paint to slow rust. UPGRADE EVALUATION: None. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1500.00 Upgrade $ 00.00 Demolition $ 5500.00 BOLEY CONSULTING ENGINEERS III , 120 r MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS Building 275 Swimming Pool AL ' 275 - Swimming Pool GENERAL DESCRIPTION: r Swimming Pool. ' FIELD OBSERVATIONS: r The surrounding pool deck has numerous cracks. Coping has large cracks with vertical displacement. rThe pool is empty except for rain water. Surrounding wood fence and pool equipment enclosure are deteriorating. Circulation pump has been removed. Heater in very poor condition. ' 9335.01\BUILD275.DOC 121 GOULD ARCHITECTS r MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: A pool contractor should inspect the pool and equipment if any ' resumption of use is to be considered. Because of the amount of damage to the concrete deck, coping, fence, ' pool equipment enclosure and missing pool equipment, restoration of the pool may be economically impractical ' Preventative Maintenance Measures: • Drain pool. • Remove loose broken concrete. Building 275 - Swimming Pool ' 9335.01\BU1LD275.D0C 122 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 275 Structural Evaluation Swimming Pool BUILDING DESCRIPTION: Pool structure- In ground concrete pool has hairline cracks, but generally appears sound. The coping and concrete decks around the pool are extensively cracked and uneven. EXISTING CONDITIONS: Pool empty except for rain water and debris. PERFORMANCE EVALUATION: MAINTENANCE EVALUATION: Caulking and cleaning. UPGRADE EVALUATION: Further studies required ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 1000.00 Upgrade $ 5000.00 Demolition $ 2500.00 BOLEY CONSULTING ENGINEERS 123 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT 1 MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS 1 Building 276 Bath House ' Building 276 -Bath House GENERAL DESCRIPTION: 1 A 400 +/- square foot concrete masonry building constructed in 1966. It is built on a concrete slab on grade. The roof is a flat built-up roof. 1 FIELD OBSERVATIONS: 1 The masonry shell appears to be in good condition. 1 Roof flashing paint is peeling. Chemical deposits inside appear to be causing paint to peel. 1 EVALUATION: Maintenance, Repair and Upgrade Measures: • Building should be repainted. 1 9335.01113UILD276.DOC 124 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION • Chemical deposits should be removed from masonry walls, treated amd refinished. ' Preventative Maintenance Measures: ' • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. • Close openings to prevent insect and rodent infestation. p i r Building 276 - Bath House ' 9335.01\BUILD276.DOC 125 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY SUPPORT BUILDINGS rBuilding XXX Fire Hose Houses ' 1 i Building XXX - Fire Hose Houses GENERAL DESCRIPTION: Wood frame, shed roof and air of wood doors containing P � g hydrant and hose. ' FIELD OBSERVATIONS: ' Most of these structures have fallen over or are completely gone. The few left standing are in varying states of disrepair. EVALUATION: The enclosure and hoses are not necessary if fire trucks are provided. If the same system is to be re-instituted, the enclosures should be rebuilt. 1 9335.01WU-DXXX.D0C 126 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARY - ' RESIDENTIAL BUILDINGS ' Building 229 Airm en's s Dormitory (231, 240, 242 & 244 sim ) 1 -,a -7 , t- ;. qt ' Building 229 -Airmen's Dormitory GENERAL DESCRIPTION: ' Only foundations remain. EVALUATION: Remove foundations and regrade site. 1 9335.01\BW D229.DOC 127 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARY - RESIDENTIAL BUILDINGS ' Building 233 Airmen's Dormitory & Chapel Building 233 - Airmen's Dormitory & Chapel GENERAL DESCRIPTION: This is a 2,920 +/- square foot re-en ineeered metal building of q P g S unknown construction date. The walls and gable roof are corrugated metal. It is built on a raised wood floor. The building was heated and ventilated, no air conditioning. Main electrical service is overhead. FIELD OBSERVATIONS: ' The corrugated metal siding and roof show signs-of rusting. Substantial water damage to ceilings, walls and floors. The "spongey" ' feel of the floor indicates possible dry rot damage to floor structure. The electrical service and lighting are in poor condition. ' 9335.01WELD233.DOC 128 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION EVALUATION: Maintenance,Repair and Upgrade Measures: • Rust spots should be removed from siding and roof and refinished. • New door should be installed. • Damaged ceiling, walls, floor, heating and ventilating systems, electrical distribution system and lighting fixtures should be replaced. • Foundation system should be laterally braced. Water damaged floor system should be replaced. Preventive Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardwar. Board up and make weather tight all other doors. • Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris. • Close openings to prevent insect and rodent infestation. 9335,011BUMD233.DOC 129 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION I ' Building 233 Structural Evaluation Airmen's Dormitory & Chapel BUILDING DESCRIPTION: Steel frame "Butler" building with steel bents in the transverse direction and rod bracing in the roof. Corrugated metal roof and siding. Wood frame/plywood floor supported by concrete grade beam perimeter footings with pier/columns at the south end. EXISTING CONDITIONS: Grade beam/pier foundations appear to be precast. Building longitudinal wall bracing is not visible. Roof and siding are rusted in numerous places. Floor at north end water damaged. PERFORMANCE EVALUATION: Lightweight steel building should perform fairly well- Concrete beam-column foundations anchored by north end perimeter foundations. MAINTENANCE EVALUATION: Paint roof and siding to slow rust. UPGRADE EVALUATION: Laterally brace south beam/column foundations. Replace water damaged floor plywood and joists. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2500.00 Upgrade $ 8000.00 Demolition $ 18000.00 BOLEY CONSULTING ENGINEERS 130 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 233 Mechanical/Electrical Inspection CHAPEL/CERAMICS BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via two oil fired Rossaire heating and ventilating units which duct air to the ceiling space. Fuel oil is fed from the underground distribution system. PLUMBING There are two bathrooms with lavatory, water closet and janitor sink. One bathroom has a shower. An electric water cooler has been removed from the wall. Domestic hot water is made with an electric 30 gallon heater. There is also a dark room area for photo developing. It has 3 sinks with hot and cold water. An exhaust fan and ductwork is in this room for fume control and appears to be in good condition. ELECTRICAL Main service is routed overhead from pole 65 to a Square D distribution panel with a 100 Amp, 120/220, 10 volt capacity and is in poor condition. The interior wiring and conduit appears to be in poor condition. Lighting is fluorescent and is in poor condition. Ceilings are deteriorated. OVERALL COMMENTS: SAFETY: The electrical service conductors do not fit the lugs and have stray strands. Lugs are too small for the wire used. Also, water heater connections are dangerous if it was ever energized again. SALVAGE: None. FUTURE USE: The building's mechanical, electrical, and plumbing equipment would need a complete renovation to be used again. sobe.B100 SALAS O'BRIEN ENGINEERS, INC. 131 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 - z r � Building 233 - Airmen's Dormitory and Chapel 9335.01\PHOTO.233 132 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION BUILDING TYPE SUMMARY - SECTION 2 RESIDENTIAL BUILDINGS Building 505 Carport * t t l r3 hr 1 711 1•a.�wi uftt Building 505 - Carport GENERAL DESCRIPTION: ' This is a 4,870 +/- square foot building constructed in 1958. The back walls are poured-in-place concrete which function as a retaining wall for the slope behind. The two end walls are stone. The roof deck rests on steel beams supported on pipe columns. It is built on a concrete slab 1 on grade. FIELD OBSERVATIONS: ' Roof beams show evidence of checking. Pipe columns are rusting. Roof attachment to back wall is suspect. Appears to be water damage in the storage units. ' Very large bubbles are apparent in the roof membrane. Leaves have collected on the flat roof, possibly clogging roof drains. Roof flashing is in poor condition. ' 9335-01TUH-D505.DOC 133 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Guardrail is unstable and non-conforming to code requirements. EVALUATION: Maintenance,Repair and Upgrade Measures: 9 This structure may be functionally obsolete without full use of the adjacent residential structures. o Steel and ends of wood beams should be painted to slow deterioration. o Roofing and damaged substrate should be replaced. o Guardrail should be replaced. o Water damaged wood and walls in storage units should be replaced. 9 Roof drainage should be verified and drain pipes should be cleared. Preventive Maintenance Measures: 9 Repair damaged or missing guardrails. o Remove damaged light fixtures, walls, ceilings, etc., clean up and remove debris from roof and roof drains. o Close openings to prevent insect and rodent infestation. 1 1 9335.01\BURD505.DOC 134 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 505 Structural Evaluation BUILDING DESCRIPTION: Open carport with wood framelwood deck roof supported by steel WF beams and steel pipe columns at front. A concrete retaining wall exists at the rear and stone retaining walls occur at each end. Concrete slabs are the parking surface. EXISTING CONDITIONS: Checking exists in the wood roof beams and the pipe columns are rusting. Longitudinal lateral bracing depends solely on the roof attachment to the rear wall and is suspect. PERFORMANCE EVALUATION: Lateral performance in the longitudinal direction could be a problem. MAINTENANCE EVALUATION: Paint steel& ends of wood beams to slow deterioration. UPGRADE EVALUATION: 1 Add lateral bracing to the structure and verify attachment of the roof to the retaining wall. i ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 500.00 Upgrade $ 4000.00 Demolition $ 15000.00 I 135 BOLEY CONSULTING ENGINEERS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION ' SECTION 2 BUILDING TYPE SUMMARIES - RESIDENTIAL BUILDINGS ' Building 510-514 Family Housing (Fourplex) Air- 41 1 - �0 1 tG1 ' Building 510 - Family Housing GENERAL DESCRIPTION: ' These are residential 2-story wood structures constructed in 1958 with flat,tar and gravel roofs and a combination of stucco and wood siding. FIELD OBSERVATIONS: Exterior materials and finishes show effects of exposure to the weather. Paint is peeling, wood trim is warped and pulling away from the building, Eaves and soffits are deteriorating. The landscape is overgrown and could cause damage to foundations. Broken windows allow rain, humidity, cold and heat to enter the buildings. Interior finishes and materials are deteriorating due to the lack of normal heating and cooling, and exposure to rain and humidity. ' Hardwood and vinyl floors have warped and come lose. Paint on walls and around windows is peeling. Mildew in the ceilings and around the windows may be from water leakage. ' 9335.01\BU1]..D510.D0C 136 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Some evidence of sewer back-up in the bathrooms. Residue on floors and countertops. Rodent and insect infestation is evident in all units. Structurally, all buildings should exhibit good seismic performance. Heating and ventilating systems are in fair condition. Electrical system is in good condition except receptacles are not grounded. Servicehead connections have pulled out of fascias. EVALUATION: Maintenance,Repair and Upgrade Measures: • All roofs for leaks should be inspected, exterior trim, flashing, and broken windows should be replaced. 1 • Peeling paint should be removed and stucco should be repaired. • Defective plumbing, damaged ceilings, walls, floors, ceramic the should be replaced. • Loose service heads should be reattached. • Lateral bracing should be added to carports. Preventative Maintenance Measures: • Secure building entrances. Lock doors that have functioning hardware. Board up and make weather tight all other doors. e Remove broken windows and make weather tight. • Remove damaged light fixtures, walls, ceilings, etc.. Clean up and remove debris. • Close openings to prevent insect and rodent infestation. 9335.011BUILD510,DOC 137 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE .DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 510 Structural Evaluation Family Housing BUILDING DESCRIPTION: Two story wood frame stucco residential building. Roof and second floor are sheathed with plywood, as are exterior walls. First floor is concrete slab on grade with framed floors occurring in some areas. Concrete strip footings support the building with concrete retaining walls at below grade areas. EXISTING CONDITIONS: Exposed wood fascias, screens and railings are very deteriorated. Building interior gyp. board relatively crack free. PERFORMANCE EVALUATION: Basically a simple wood frame box system that should exhibit good seismic performance. ' MAINTENANCE EVALUATION: Exposed wood pretty much gone so paint not necessary. UPGRADE EVALUATION: Replace exposed wood components. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2004.40 Upgrade $ 11000.00 ill , Demolition $ 18000.00 BOLEY CONSULTING ENGINEERS 138 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 511 Structural Evaluation Family Housing BUILDING DESCRIPTION: Two story wood frame stucco residential building. Roof and second floor are sheathed with plywood, as are exterior walls. First floor is concrete slab on grade with framed floors occurring in some areas. Concrete strip footings support the building with concrete retaining walls at below grade areas. EXISTING CONDITIONS: Water damage noted in units 2A and 2C in the ceilings, walls and floors of the bathrooms and hall. Exposed wood fascias, screens and railing are very deteriorated. . PERFORMANCE EVALUATION: Basically a simple wood frame box system that should exhibit good seismic performance. MAINTENANCE EVALUATION: Fix floor leak. Exposed wood pretty much gone so paint not necessary. UPGRADE EVALUATION:U ON: Replace exposed wood components. ESTIMATE OF PROBABLE CONSTRUCTION COST:Maintenance $ 2000.00 Upgrade $ e 20000 00 pg Demolition $ 17500.00 BOLEY CONSULTING ENGINEERS 139 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 512 Structural Evaluation Family ' Housing BUILDING DESCRIPTION: Two story wood fame stucco residential building. Roof and second floor are sheathed with plywood as are exterior walls. First floor is concrete slab on grade with framed floors occurring in some areas. Concrete strip footings support the building with concrete retaining walls at below grade areas. EXISTING CONDITIONS: Water damage to wall and floor of back bedroom Apt. 3B and ceiling of back bedroom in Apt. 3D. Water damage to wall and floor in Apt. 3A and 3C in rear bedroom and hall. Exposed wood fascias, screens and railing are very deteriorated. PERFORMANCE EVALUATION: Basically a simple wood frame box system that should exhibit good seismic performance. MAINTENANCE RECOMMENDATION: Locate and fix leaks. Exposed wood pretty much gone so paint not necessary. UPGRADE RECOMMENDATION: Replace exposed0 wood components.onents. P ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 24000.00 Demolition $ 17500.00 BOLEY CONSULTING ENGINEERS 140 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT ' MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 513 Structural Evaluation Family ' Housing BUILDING DESCRIPTION: Two story wood frame stucco residential building. Roof and second floor are sheathed with plywood as are exterior walls. First floor is concrete slab on grade with framed floors occurring in some areas. Concrete strip footings support the building with concrete retaining walls at below grade areas. EXISTING CONDITIONS: Water damage noted at the following locations;wall at rear bedroom Apt. 4C, 4B &4D;bathroom floor, wall& ceiling Apt. 4B &4D; floor buckling in unit 4B. Exposed wood fascias, screens and railing are very deteriorated. PERFORMANCE EVALUATION: Basically a simple wood frame box system that should exhibit good seismic performance. MAINTENANCE EVALUATION: Locate leaks and repair. Exposed wood pretty much gone so paint not necessary. UPGRADE EVALUATION: Replace exposed wood components. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 24000.00 Demolition $ 17500.00 BOLEY CONSULTING ENGINEERS 141 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTO RY AND EVALUATION Building 514 Structural Evaluation Family Housing BUILDING DESCRIPTION: Two story wood frame stucco residential building. Roof and second floor are sheathed with plywood as are exterior was. First floor is concrete slab on grade with framed floors occurring in some areas. Concrete strip footings support the building with concrete retaining walls at below grade areas. EXISTING CONDITIONS: Water damage was noted in the family room ceiling, wall and floor Apt. 5A& 5C, in rear bedroom Apt. 5C, 5D& 5B and at rear door Apt. 5D. Exposed wood fascias, screens and railings are very deteriorated. PERFORMANCE EVALUATION: Basically a simple wood frame box system that should exhibit good seismic performance. MAINTENANCE EVALUATION: Locate and repair leaks. Exposed wood pretty much gone so paint not necessary. UPGRADE EVALUATION: Replace exposed wood components. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 30000.00 Demolition $ 17500.00 BOLEY CONSULTING ENGINEERS 142 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 510-17 Mechanical/Electrical Inspection FAMILY HOUSING BUILDING HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: Building heating was accomplished via one oil fired Borg Warner heating and ventilating unit for each apartment. The first floor has ductwork under the concrete floor slab with floor registers in all rooms. The second floor apartments has ductwork up in the ceiling attic and has wall registers in each room. A central return grille in the hallway for all of the apartments allows return air back to the furnace. The furnaces look in fair condition and could probably be re-furbished to work again. Fuel oil is fed from the underground distribution system. PLUMBING There is one bathroom per apartment with lavatory, water closet and tub/shower. Domestic hot water is made with an electric 52 gallon A.O. Smith water heater located in the same mechanical closet. Each apartment has its own water heater. The kitchen has a double sink with hot/cold water and has connections for a clothes washer and electric clothes dryer. Each apartment building had an exposed valve for the cold water shutoff. A cleanout for the kitchen waste line is on the exterior of each apartment; some are missing which has allowed bees to enter and establish a hive. ELECTRICAL Main service is routed overhead from a pole to a G.E. distribution panel with a 100 Amp, 120/220 Volt, 10 capacity and is in fair condition. The interior wiring and conduit appears to be in good condition; however all of the receptacles are ungrounded. Weatherhead connections at roof eaves are rotted,and some have pulled out of the facia attachment. Kitchen and bathroom outlets have no GFI receptacles. Lighting is incandescent and is in good condition. OVERALL COMMENTS: SAFETY: Electrical Service heads need reattachment on Unit # ' 513 and 514. SALVAGE: None. ' FUTURE USE: Since both the heating system and water system appears to be in fair-good condition, renovation of these units could be done to bring up to habitable standards. so1r,:B100 SALAS O'BRIEN ENGINEERS, INC. 143 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT 1 MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 1 1 1 1 1 1 1 - v:. s 4F $} f Building 510- Family Housing 1 9335.01\PHOTO.510 144 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION •J�``-, _ ti i , Building 510- Family Housing 9335.01\PHOTO.510 145 GOULD ARCHITECTS t MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARIES - RESIDENTIAL BUILDINGS ' Building 515,517 Family Housing (Triplex) mill ' Building 515 - Family Housing GENERAL DESCRIPTION: ' These are residential 2-story wood structures constructed in 1958 with flat,tar and gravel roofs and stucco siding. FIELD OBSERVATIONS: ' Exterior materials and finishes show effects of exposure to the weather. Paint is peeling, wood trim is warped and pulling away from 1 the building, eaves/soffits are deteriorating. The landscape is overgrown and could cause damage to foundations. Broken windows allow rain, humidity and cold/heat to enter the buildings. Interior finishes and materials are deteriorating due to the lack of normal heating and cooling, and exposure to rain and humidity. ' Hardwood and vinyl floors have warped and come lose. Paint on walls and around windows is peeling. Mildew in the ceilings and around the windows may be from water leakage. ' 9335.01\13UMD515.DOC 146 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Some evidence of sewer back-up in the bathrooms. Residue on floors and countertops. Rodent and insect infestation is evident in all units. Structurally, all buildings should exhibit good seismic performance. Carports have minimal lateral support. Heating and ventilating systems are in fair condition. electrical system is in good condition except receptacles are not grounded. Weatherhead connections have pulled out of fascias. One living unit in Building 515 is occupied and was not accessible. EVALUATION: Maintenance, Repair and Upgrade Measures: • All roofs should be inspected for leaks, exterior trim, flashing, and broken windows should be replaced. • Peeling paint should be removed and stucco repaired. • Defective plumbing. Damaged ceilings, walls, floors and ceramic the should be replaced. • Loose service heads should be reattached. • Lateral bracing should be added to carports. Preventive Maintenance Measures: • Same as 510-514. 9335.01\BLJ1LD515.D0C 147 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 51 5 Structural Ev aluation BUILDING DESCRIPTION: Two story wood frame triplex building. Roofs and floors are wood joists sheathed with plywood. Exterior walls are t plywood sheathed with some masonry walls on the front. Wood frame carports attach to the front of the building. The building is on perimeter concrete footings. EXISTING CONDITIONS: Water damage was noted in kitchen wall of unit B and first floor of Unit A PERFORMANCE EVALUATION: Simple wood frame building should perform well seismically. Carports have minimal lateral support. MAINTENANCE EVALUATION: Locate roof leaks and repair. i UPGRADE EVALUATION: ' Add lateral bracing to the carports and verify attachment to the building. Carport bracing could consist of simple knee braces at the posts. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 24000.00 i Demolition $ 17500.00 BOLEY CONSULTING ENGINEERS ' 148 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 17 d g 5 Structural Evaluation ' BUILDING DESCRIPTION: Two story wood frame triplex building. Roofs and floors are wood joists sheathed with plywood. Exterior walls are plywood sheathed with some masonry walls on the front. Wood frame carports attach to the front of the building. The building is on perimeter concrete footings. EXISTING CONDITIONS: ( Water damage to Unit B, second floor and Unit C, first and second floor/ceilings. Carports are laterally braced only by there attachment to the building. PERFORMANCE EVALUATION: Simple wood frame building should perform well seismically. Carports have minimal lateral support. MAINTENANCE EVALUATION: Locate roof leaks and repair. UPGRADE EVALUATION: Add lateral bracing to the carports and verify attachment to the building. Carport bracing could consist of simple knee tbraces at the posts. iESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 2000.00 Upgrade $ 20000.00 Demolition $ 17500.00 BOLEY CONSULTING ENGINEERS 149 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION 70 i 4 ' 1t t � / I - Building 517- Family Housing 9335.011PHOTO.517 150 GOULD ARCHITECTS 1 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION SECTION 2 BUILDING TYPE SUMMARIES - RESIDENTIAL BUILDINGS ' Building 516 Family Housing (Detached Single Family) J;�;�4P AWE x ZR++ ». ' Building 516 - Family Housing GENERAL DESCRIPTION: ' This is a one story wood structure constructed in 1958 with a flat, tar and gravel roof and stucco siding. ' FIELD OBSERVATIONS: Building 516 is occupied and not accessible. The exterior appears to have been maintained. ' 9335.01\BUILD516.DOC 151 GOULD ARCHITECTS MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNH[UM FACILITIES INVENTORY AND EVALUATION Building 516 Structural Evaluation Family Housing BUILDING DESCRIPTION: Single story wood frame residence. Roof and floor are ' plywood sheathed wood frame resting on concrete perimeter foundations. Wood frame carport is attached to the front of the house and low wood deck patio occurs at rear. EXISTING CONDITIONS: Some cracks noted in the exterior stucco, eave joists appear rotted, carport beams sag somewhat. Carport roof may lack full lateral bracing. PERFORMANCE EVALUATION: Simple single story residential building should perform well seismically. 1 MAINTENANCE EVALUATION: None. UPGRADE EVALUATION: Verify carport attachment to building. ESTIMATE OF PROBABLE CONSTRUCTION COST: Maintenance $ 00.00 Upgrade $ 00.00 Demolition $ 8000.00 BOLEY CONSULTING ENGINEERS ' 152 MIDPENINSULA REGIONAL OPEN SPACE DISTRICT MT. UMUNHUM FACILITIES INVENTORY AND EVALUATION Building 510-17 Mechanical/Electrical Inspection FAMILY HOUSING BUILDING ' HEATING, VENTILATING & AIR CONDITIONING SYSTEMS: ' Building heating was accomplished via one oil fired Borg Warner heating and ventilating unit for each apartment. The first floor has ductwork under the concrete floor slab with floor registers in all rooms. The second floor apartments has ductwork up in the ceiling attic and has wall registers in each room. A central return grille in the hallway for all of the apartments allows return air back to the furnace. The furnaces look in fair condition and could probably be re-furbished to work again. Fuel oil is fed from the underground distribution system. PLUMBING There is one bathroom per apartment with lavatory, water closet and P P rY� tub/shower. Domestic hot water is made with an electric 52 gallon A.O. Smith water heater located in the same mechanical closet. Each apartment has its own water heater. The kitchen has a double sink with hot/cold water and has connections for a clothes washer and electric clothes dryer. Each apartment building had an exposed valve for the cold water shutoff. A cleanout for the kitchen waste line is on the exterior of each apartment; some are missing which has allowed bees to enter and establish a hive. ELECTRICAL Main service is routed overhead from a pole to a G.E. distribution panel with a 100 Amp, 120/220 Volt, 10 capacity and is in fair condition. The interior wiring and conduit appears to be in good condition; however all of the receptacles are ungrounded. Weatherhead connections at roof eaves are rotted, and some have pulled out of the facia attachment. Kitchen and bathroom outlets have no GFI receptacles. Lighting is incandescent and is in good condition. OVERALL COMMENTS: SAFETY: Electrical Service heads need reattachment on Unit # 513 and 514. SAL%*AGE: None. FUTURE USE: Since both the heating system and water system appears to be in fair-good condition, renovation of these units could be done to bring up to habitable standards. sobas100 SALAS O'BRIEN ENGINEERS, INC. 153 ' SECTION 3 APPENDIX r rr r rr rr rr rr r rr rr r rr r r rr �r rr rr r Drawing index Page DWG # Date Num Building Tye of Drawing AF31-09-02 8 Recreation Bldg. Electrical 9 Mechanical 101 Mechanical ALM-210-214.12 "2 1 I.E. Maintanaince Shop Electrical, Site & Floor Plans Sewa a and Oil Storage AW38-12-03 13 Ground-Air Transmitter Reciever Bldg. Power Line Plan & Profile STA 0+00 to 4+40 14 Power Line Plan & Profile STA 4+40 to 21+55 15 Power Line Plan & Profile STA 21+55 to 36+40 16, Power Line Plan & Profile STA 36+40 to 53+05 171 Utility & Plan Details 18 Utility Details AW38-12-24 24 Plumbing 25 Heating 26 Electrical Plan & One Line Diagrams 27 Electrical Schedules & Details M96-140-700.58 3 Add. Corn Trans/Rec. Bldg. 700 Mechanical floor plan and details Electrical Floor Plan, Partial Riser Diagram, & Fixtrure 4 Detail AF26-03-02 6 Emergency Power Bldg. Electrical Plan 7 Electrical Sitework 8 Electric Details 9 Mechanical Site Plan 101 Mechanical Plan 11 Mechanical Details M-96-840-200.57 DATE 1 Alt. Water Pump Station Bldg. 200 Site Plan 2 Mechanical Plan 31 Supply Storage Tank Site Plan AW71-05-03 8 Pump Station No. 1 & 2 Electrical 9,Existing Access Road Water Supply- Arial Electrical & Water Lines 71-05-02 1 Water Collection System Elevations, Fitting Assemblies and Profile 71-08-01 1 Comtainment Area-Outside Utilities Water, Sewage, & Oil Plans 17A Treatment Water, Sanitary Sewer, Fuel Oil 71-08-01 2 O erations Area- Outside Utilities Water, Sewer, and Oil Page 1 Drawing index 41 Electrical 51 Exterior Cable Trenches 71sewage Treatment Facilities Electrical, Plumbing, and Plan Views DELETE I ALM 851-005 Jan-72 1 lWater Annex Road Plans & Details for Repair 71-05-01 Aug-55 1 Water Supply-Pumphouse 1&2 and Water Tank Foundations, Wiring, and Schematics 2 Water Supply & Sewage Disposal Details 3 Water Supply & Spring Location Plan AW71-05-03 Aug-58 6 Water Supply Pump Station #1 Plans, Elevations, & Details 7 Water Supply Pump Station #2 Plans, Elevations, & Details 137 - Site Plan Site Plan M96.710-001 May-58 321FY' Family Ho using-Four lex Heating & Electrical 331 Plumbing Layout 34 FY' Family Housing-Triplex Heating Layout 35 Plumbing & Electrical 36 FY' Family Housing- Four People Heating, Plumbing, & Electrical M96-71 0-001 May-58 8 FY' Family Housing Electrical Distribution Plan M96-71 0-001 May-58 6 FY' Family Housing Water & Sewer Plan As Builts) ALM-711-005 Mar-71 2 27 F/H Units Furnace Replacements As Builts) 31 AW26-03-03 Jan-61 1 Electrical Power Building & Distribution Site Location Map & Schedule of DWGS 21 Site Plan 31 Grading Plan 41 Sewage Disposals & Misc. Details 51 Misc. Site Details 7 Mechanical Site Plan 8 Fuel Storage & Misc. Details 9 Fuel Pump House & Mechanical Details 10 Mechanical Details 11 Electrical Site Plan 12 Single-Line Diagram 13 Transformer Station Details 14 Electrical Details 15 Electrical Details 16 Electrical Ducts & Manholes 17 Salvage & Relocation 26 Misc. Details Page 2 Drawing index 47 Console Connection Schedules AW-60-04-06 Mar-63 4 Nuclear Fallout Shielding-Gatr Bldg. Floor Plan, Elevations, & Sections Power Plant for AC & W. Stations (800/850kw AW26-03-87 Jan-61 42 Units) Engine Jacket Water Piping Diagrams- Radar 43, Electrical Lower Level Plan 44 Electrical Floor Plan 37 Engine Pi in - Lower Level Plan Radiator Cooling 38 Sections 39 Engine Piping - Details & Schedules Feb-04 40, Engine Fuel Oil Piping Dia�rams 411 Engine Lube Oil Piping Diagrams Jan-61 251 Toilet Room & Misc. Details 451 Electrical Schedules 46 Electrical Riser Diagram M96-200-211.46 Jan-64 1 Alt. Auto Mechanic Shop Floor Plan, Site Plan, & Grease Pit Details 3 Plumbing, Mechanical, & Oil Storage Tanks M96-200-211.46 Jan-64 4 Alt. Auto Mechanic Shop Electrical, Equipment Schedule 35-02-01.2 Feb-57 3 Automotive Shop Mechanical & Electrical ALM-210-214.11 May-61 8 Automotive Maint. Shop Mechanical 9 Electrical May-69 1 Site View Primary Electrical Distribution System ALM-812-001 May-68 2,Pump House Line (Maint.) Prim Dist Line OH As Builts) ALM-710-435.37 Aug-59 1 Fuel Oil Fill Line Plans & Details ALM-812-001 May-68 1 Cantonment Lines (Maint.) Prim Dist Line OH As Builts) M96 Mar-70 B General Layout (Reduced Drawing) 51 Jan-58 Utility Map Fuel Oil 35-16-01 Oct-57 2 Technical Supply Bldg. Mechancial & Electrical ALM-800-119.18 Aug-58 1 Bldgs. 119,212,213,230,& 245 Installment of Fire Alarm System- Plot Plan 2 Details 31 Typical Installation Details ALM 842-001 Sep-70 1 Alt. Firing Pump- Automatic Starting System Site Plan, Schematics, & Details Fire Alarm Systems Bldgs. 205,207, 225, 229, ALM 800-205.06 Oct-57 1 231, 233, 240, 242, 244 Site Plan 2 Floor Plans 31 Typical Installation Details AW38-07-01 Jun-60 1 Opperations Bldg. Addition Site Location, & Vicinity Maps - Schedule of DWGS 21 Site Utilities & Gading Plan Page 3 Drawing index 31 Floor Plan, Elevations, & Details 8 Mechanical Plans & Details 9 Mechanical Plans & Sections 10 Mechanical Diagrams & Details 11 Mechanical Diagrams & Details 12, Electrical Plans & Details 131 Misc. Electrical Details 30-07-03 Nov-59 1 10perations Bldg. Air Conditioning Modification Site Plan, Schedule of DWGS, & Details 2 Floor Plans & Sections 3 Plan Details & Sections 4 Schematic Diagrams & Details 5 Electrical Plan, Section, & Diagram 60-02-63 May-601 21 FD Radar Facilities-FPS-35/24 (concrete) Electrical-One Line Diagram 22 Electrical-Misc. Wiring Diagrams 23 Electrical-Misc. Wiring Diagrams Electrical-Lighting, Communications, & Alarms (1 st & 24 2nd Floor Plans Electrical-Lighting, Communications, & Alarms (3rd & 251 4th Floor Plans Electrical-Lighting, Communications, & Alarms (5th 26 Floor, Mezz, & Roof Plans 27 Electrical-Conduit & Grounding (1st & 2nd Floor Plans) 28 1st Foor - Part Plan 29, 2nd Floor Part Plan 301 3rd & 4th Floor Part Plan & 5th Floor Plan 311 Electrical-Misc. Sections & Details 32 Electrical-Lighting Plan- 3rd Floor 33 Electrical-Conduit & Grounding (3rd Floor Plan) 34 5th Floor & Roof Plans 35 Electrical-One Line Diagram 36, Electrical-Lighting Plan (4th Floor) 371 Electrical-Conduit & Grounding (4th Floor Plans) 381 Electrical Details Mechanical-Flow Diagrams, Heating, Ventilating, A/C, 39 & Pi ing Mechanical-Composite Arrangement of Piping (1st 40 Floor Plan & Sections) Page 4 Drawing index Mechanical-Heating, Ventilating, & A/C (1st & 2nd 41 Floor Plan & Sections) 42 5th Floor Plan & Sections Mechanical-Composite Arrangement of Piping (2nd & 43 5th Floors Plans & Sections 44 Details 45 Heating, Ventilating, & A/C (3rd Floor Plan & Sections) 46 4th Floor Plan M96-750-275.72 1 Swimming Pool Title Sheet 30-01-01 Oct-57 2 Addministration Bldg. Mechancial & Electrical ALM-740-245.13 A r-61 5 Bowling Alley Electrical 6 Heating & Ventilation 7 Plumbing & Utility Plan M96-700-233.53 Mar-64 3 Dorm. Amn. Bldg. 233 Heating, Electrical, & Plumbing Plan ALM 540-213.19 Nov-61 3 Dental Clinic Bldg. 213 Electrical & Heating- Plans & Notes 41 Plumbing Plan & Schedule ALM/B-005 1 Rehabilitate Latrine Bldg. 233 Site Plan & Installation Details 21 Counter & Fixture Details ALM/E-003 Jun-75 11 NCO Club Replace Electric Wiring ALM/E-002 Nov-74 1 IFire Protection- Pump Station Single Line Diagrams ALM E-001 A r-74 1 Bldg. 100 & 217- Inst Auto Fire Detect System Floor Plans & Site Plan Bldg. 112, 120, 211, &225 Floor Plans ALM/F-001 Nov-74 1 Va or Recove S stem Location Map & Details ALM/H-002 Au -74 1 Bldg. 517 & 515 Emer . Repair Heating Schematics & Floor Plans ALM/H-001 A r-74 1 Bldg. 110, 205, & 207 Heating System 2 Bldg. 213, 217, & 230 Floor Plans 3 Bld . 119 & 211 Floor Plans & Location Maps 4 Bld . 229, 231, 233, 240, 242, & 244 Floor Plan M97-700-205-44 Jul-63 1 Showers Bld s. 205, 229, 231, 240, 242, 244 Plans & Layouts 25-06-01 Oct-57 1 B.O.G. Plans, Elevations, & Sections 2 Mechanical & Electrical 31-09-01 2 Recreation, Training, & Dispensing Bldg. Mechanical & Electrical 21-01-01 2 Barracks Mechanical & Electrical 33-34-01 Au -67 2 General Supply Bld . Mechanical & Electrical 16-15-01 Au -55 1 General Site Plan Plan & Schedule of DWGS 2 Cantonment Area Location & Grading Plan M96-720-225.79 Oct-651 2 Maint. Dining Hall Bldg. 225 Mechanical Page 5 I I I Drawing index ALM-730-225.18 Oct-61 3 Airmens Dining Hall Bldg. 225 Revised Mechanical Plan & Mechanical Details Revised Electrical Floor Plan, Typical Recessed light, 4 Detail Revised Pannel Schedule & Legend 36-05-01 Oct-57 6 Mess Hall Heating & Ventilating 7, Plumbi.nq 8 Electrical ALM/B-007_ Sep-75 2 Amn. Dining Hall Install False Ceiling -Partial Plans 3 Install False Ceiling- Lighting &..Ceiling Plans 4 Ran Hood 5 Steam Table Hood 61 Light Fixture ALM/B-004 Sep-74 8 Dinning Hall Bldg. 225? Ceiling Plan 9 Heating, A/C, & Ventilating 10 Piping__._ 11 Mechanical Schedules ALM/H-003 Sep-75 1 Mess Hall Bldg. 225 Steam & Condensate Lines Waste Treatment & Disposal Facilities-Lab & ALM/W-001 Mar-74 1 Control Room Location Map & Index 2 Site Plan & Details 3, Grading Plan 4 To Floor Plan & Details 5 Lower Floor Plan Section 6 Sections & Details 11 Pond Excavation & Gading- Misc. Details & Schematics 12 Electrical Site Plan Details 1 13, Electrical To Floor Plan & Schedules 1 141 IElectrical Lower Floor Plan & Diagrams Page 6 ' BUILDING SURVEY/JOB NO. 9335.01 /DATE 3-4-94- GOULD ARCHITECTS ' Bldg. Name Building Types Existing Conditions No. Military Support Residential Construct Special Site Architect Struct Plumbing Fire HVAC Electrical ' COMMON sPEClnC Type Features Protection I 1 FLAGPOLE 0 ❑ _ 2 NOT USED ❑ ❑ ❑ ❑ J, -- - ❑ ❑ ❑ ❑ 99 NOT USED ❑ ❑ ❑ CT-2 CT-5 PS-2 CD-2 P-1 PS-2 P-1 P-4 CD-2 PS-2 PS-2 100 OPERATIONS ® ❑ ❑ ❑ CT-4 P-1 P-4 - ( ' 101 NOT USED El ❑ ❑ ❑ _ - _ f 102 RADAR TOWER FPS-24 ® ❑ El ❑ CT-3 CT-5 PS-2 CD-2 P-1 PS-2 PS-2 P-4 PS-1 103 HELICOPTER LANDING PAD _ ❑ _ _ ® ❑ ❑ CT-S _ PS-1 P-3 PS-1 FDN ONLY _ 104 NOT USED ❑ ❑ ❑ ❑ - -- - - - CT-2 UNDERGROUND PS-1 P-1 CD-1 __ P-4 PS-2 P--4 PS-2 PS-2 105 PROTECTIVE SHELTER ® ❑ ❑ ❑ srRucruRE ❑ ® ❑ El ONLY PS-1 P-1 FDN ONLY 106 WIND MEAS. SET - - - - - -- __. -- -- PS-1 P-1 MN ONLY 107 RADAR TOWER FPS-90 ® ❑ ❑ ❑ MN ONLY - CT-2 PS-1 P-1 108 RADAR TOWER FPS-14 ® ❑ ❑ ❑ -- -- -- 109 NOT USED ❑ ❑ ❑ ❑ - -- _ CT-2 CT PS-1 P-3 PS-1 PS-1 - P-1 CD-1 110 TRAINING BUILDING ❑ ❑ ® ❑ -- PS-_1 111 NOT USED ❑ ❑ El El -- ❑ ® ❑ CT-2 CT-5 PS P-3 C0-1 PS-1 112 ELECTRIC POWER STA. ❑ P-4 ' __. CT 113 NOT USED ❑ ❑ El 114 STORAGE (SHEET & PIPE) El ® El ❑ CT-4 CT-5 PS-1 P=3 ' - - CT-2 CT-6 PS-1 P-1 PS-1 - PS-1 PS--1 — 115 GATE HOUSE ❑ ® ❑ El 116 NOT USED ❑ 0 ❑ ❑ - ' - - _- _ -_. - _ - - - i CT-4 CT-5 PS-1 P-3 PS-1 __ P-4 PS-1 117 DIESEL FUEL PUMP STA ❑ ® ❑ ❑ -- 118 NOT USED (TELCO BLDG) ❑ ❑ ❑ ❑ CT-2 CT-5 PS-1 P-3 CD__1 PS-1 PS-1 P-1 PS-2 ' 119 CE MAINTENANCE SHOP ❑ ❑ ® ❑ _ _ - PS-4 - - - ----120 WAREHSE SUPPLY & EQUIP ❑ ❑ ® ❑ CT-4 CT-5 PS-1 P-1 CD-1 PS-1 PS-2 PS-2 PS-2 P-4 - - - PS-2 i ' ❑ ❑ ❑ ❑ CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable ( ' CT-2 Steel Frame PS-2 Major Damage CD-2 Major Deficiencies P-2 High Reuse Potential CT-3 Concrete PS-3 Special Study Regd. P-3 Possible Reuse CT-4 CMU P-4 Salvageable Equipment ' CT-5 Slab on Grade BLDG—SUR.ASS/A93—B17 PAGE__1 OF 7 BUILDING SURVEY/JOB NO. a335_ol /DATF 9-9s—s4 GOULD ARCHITECTS Bldg. Name Building Types Existing Conditions ' No. Military Support Residentia Construct Special Site Architect Struct Plumbing Fire HVAC Electrical COMMON SPECIFIC Type Features Protection 121 FIRE HOSE HOUSE ❑ ® ❑ ElFM ONLY PS-1 PS-2 -- -- ' 122 El1Z ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- - II 123 ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- ' 124 El ® El FDN oNLY PS-1 PS-2 -- 125 ❑ ® ❑ ❑ FDN ONLY PS-1 PS-2 _- 126 ❑ ® ❑ ❑ FDN ONLY PS-1 PS-2 — ' FDN ONLY -- 127 El ® El El Ps—1 PS-2 -- -- -- -- 128 ❑ ® ❑ ❑ FDN ONLY PS-1 PS-2 -- -- 129 ❑ ® ❑ ❑ CT-1 PS-1 PS-2 130 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- ' 131 NOT USED ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 139 NOT USED ❑ ❑ ❑ ❑ 140 SEWAGE SEPTIC TANK ❑ ® ❑ ❑ -- P-1 -- -- CD-2 -- -- -- 141 SEWAGE SEPTIC TANK ❑ ® ❑ ❑ -- P-1 -- -- CD-2 -- -- -- 142 SEWAGE SEPTIC TANK ❑ ® ❑ ❑ -- P-1 -- -- CD-2 -- -- -- 143 SEWAGE SEPTIC TANK ❑ ® ❑ ❑ -- P-1 -- -- CD-2 -- -- -- 144 NOT USED ❑ ❑ ❑ ' 199 NOT USED ❑ ❑ ❑ ❑ _ 200 WATER PUMP STATION ❑ ® ❑ ❑ CT-2 CT-5 PS-1 PS-1 P-3 PS-1 CD-1 P-1 -- P-1 P-4 201 NOT USED ❑ ❑ ❑ ❑ 202 NOT USED ❑ ❑ ❑ ❑ 203 NOT USED ❑ ❑ ❑ ❑ 204 NOT USED ❑ ❑ ❑ O D_ ❑ ❑ CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable ' CT-2 Steel Frame PS-2 Major Damage CD-2 Major Deficiencies P-2 High Reuse Potential CT-3 Concrete PS-3 Special Study Reqd. P-3 Possible Reuse CT-4 CMU P-4 Salvageable Equipment CT-5 Slab on Grade BLDG—SUR.ASS/A93-1317 PAGE_ OF 7 j ' BUILDING SURVEY/JOB NO. g335-01 /DATF 9-98—q4 GOULD ARCHITECTS Bldg. Name Building Types Existing Condition j ' No. Military Support Residential Construct Special Site Architect Struct Plumbing Fire HVAC Electrical COMMON SPECIRC Type Features Protection 205 BACHELOR OFFICERS' QTRS ❑ ❑ ® ❑ CT-2 CT-6 PS-1 PS-1 PS-2 PS-1 P-3 PS-1 PS-1 PS-3 CD-1 P-3 -- ' 206 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -_ 207 HEADQUARTERS SQUADRON ❑ ❑ ® ❑ CT-2 CT-6 PS-1 PS-2 P-3 PS-2 PS-1 P-3 -- PS-1 PS-1 CD-1 208 NOT USED ❑ ❑ D El 209 NOT USED ❑ ❑ ❑ ❑ ' 210 NOT USED ❑ ❑ El El-'_ P-3 PS-1 211 AUTO MAINT. SHOP El El ® ❑ CT-2 CT-5 PS-1 CD-1 PS-2 PS-1 -- PS-2 PS-1 212 NCO OPEN MESS El El ® El CT-2 CT-2 CT-5 PS-2 PS-2 PS-1 PS-1 -- PS-2 PS-2 CD- ' 213 DISPENSARY El El ® I-] CT-2CT-6 PS-1 PS-1 P-3 CD-1 PS-1 PS-1 -- PS-2 PS-1 I 214 NOT USED ❑ ❑ ❑ ❑ ' 215 FIRE HOSE HOUSE ❑ ® _ _ ❑ ❑ CT-1 PS-1 PS-2 - -- -- - 216 NOT USED ❑ ❑ ❑ El® P-1 PS-PS-2 -- ' 217 BOWLING ALLEY ❑ ❑ ❑ CT-4 CT-5 PS-1 CD 2 2 PS-2 PS-2 PS-2 218 NOT USED ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 224 NOT USED ❑ El ❑ ❑ - _225 AIRMEN'S DINING HALL El ❑ ® ❑ CT-4 CT-5 PS-1 PS-2 P-1CD-1 PS-1 PS-2 -- PS-2 P-4 PS-1 226 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- 227 NOT USED ❑ ❑ ❑ ❑ ' 228 NOT USED ❑ ❑ ❑ ❑ 229 AIRMEN'S DORMITORY ❑ ❑ ❑ ® FDN ONLY CT-2 CT-5 PS-1 P-3 230 COMMISSARY ❑ El ® ElCT-1 " CD-1 P-4 CD-2(Add'n) -- -- P-4 PS-2 PS-1 j ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ D ❑ ❑ ' CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable CT-2 Steel Frame PS-2 Major Damage CD-2 Major Deficiencies P-2 High Reuse Potential ' CT-3 Concrete PS-3 Special Study Reqd. P-3 Possible Reuse CT-4 CMU P-4 Salvageable Equipment CT-5 Slab on Grade i BLDG-SUR.ASS/A93-817 PAGE__3OF 7 i ' BUILDING SURVEY/JOB NO. 9335.01 ,/DATF 9— 8-94 GOULD ARCHITECTS Bldg. Name Building Types Existing Conditions No. Military Support Residential Construct Special Site Architect Struct Plumbing Fire HVAC Electrical ' Type Features Protection COM SPC 231 AIRMEN'S DORMITORY ❑ ❑ ❑ ® MN ONLY 232 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- 233 AIRMEN'S DORM & CHAPEL ❑ ❑ El ® PS-1 CD-1 CT-2 CT-6 PS-1 PS— PS-1 PS-2 -- PS-2 PS-2 i 234 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 235 NOT USED ❑ ❑ El El_ I •L -11 ❑ ❑ ❑ ❑ 239 NOT USED ❑ ❑ ❑ ❑ 240 AIRMEN'S DORMITORY ❑ ❑ ❑ ® FDN ONLY ' 241 NOT USED ❑ ❑ ❑ ❑ 242 AIRMEN'S DORMITORY ❑ ❑ ❑ ® FDN ONLY 243 NOT USED ❑ ❑ ❑ ❑ 244 AIRMEN'S DORMITORY ❑ ❑ ❑ ® FDN ONLY ' PS-1 CD-1 245 RECREATION, MULTI—PURP. ❑ ❑ ® ❑ CT-4 CT-5 PS-1 P_3 -- PS-2 -- PS-2 PS-2 246 NOT USED ❑ ❑ ❑ ❑ ' 249 NOT USED ❑ ❑ ❑ ❑ 250 AUTO MAINTENANCE STG. ❑ ❑ ® ❑ CT-2 CT-5 PS-1 PS-1 P-3 -- -- -- -- -- 251 NOT USED ❑ ❑ ❑ ❑ 111, y ❑ ❑ ❑ ❑ 274 NOT USED ❑ ❑ ❑ ❑ I 275 SWIMMING POOL ❑ ❑ ® ❑ CT-3 PS-2 PS-2 P-1 PS-3 P-4 PS-2 -- -- -- 1 276 BATH HOUSE El ❑ ® I-] CT-4CT-5 PS-2 P-3 PS-1 — -- —_ 277 NOT USED ❑ ❑ ❑ ❑ y ❑ _ ❑ ❑ ❑ 299 NOT USED _ ❑ ❑ ❑ ❑ I ❑ ❑ ❑ ❑ j CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable ' CT-2 Steel Frame PS-2 Major Damage CD-2 Major Deficiencies P-2 High Reuse Potential CT-3 Concrete PS-3 Special Study Reqd. P-3 Possible Reuse CT-4 CMU P-4 Salvageable Equipment ' CT-5 Slab on Grade BLDG—SUR.ASS/A93—B17 PAGE 4 OF 7 I e BUILDING SURVEY/JOB NO. 9335.01 /DATA-94 GOULD ARCHITECTS i Bldg. Name Building Types Existing Conditions ' No. Military upport Residential Construct Special Site Architect Struct Plumbing Fire HVAC Electrical ' COMMON SPECIFIC Type Features Protection 300 SEWGE TRTMNT/DISP PLANT ❑ ® ❑ ❑ NOT ACCESSIBLE - _ 301 NOT USED ❑ ❑ ❑ ❑ 302 NOT USED ❑ ❑ ❑ ❑ ' 303 STORAGE (PAINT & DOPE) ❑ ® ❑ ❑ NOT A ICESSIBLE I 304 NOT USED ❑ ❑ ❑ ❑ J• J• ❑ ❑ ❑ ❑ 309 NOT USED ❑ ❑ ❑ ❑ 310 SEPTIC TANK ❑ ® ❑ ❑ NOT ACCESSIBLE ( , 311 SEPTIC TANK _ ❑ ® ❑ ❑ NOT ACCESSIBLE 312 NOT USED ❑ ❑ ❑ ❑ 414 NOT USED ❑ ❑ ❑ ❑ 415 HEATING FUEL STORAGE ❑ ® ❑ ❑ IDENTI IED FOR REMOVAL 416 NOT USED ❑ ❑ ❑ ❑ 417 NOT USED ❑ ❑ ❑ ❑ 418 NOT USED ❑ ❑ ❑ ❑ 419 NOT USED ❑ ❑ ❑ ❑ 420 STORAGE, MOGAS ❑ ® ❑ ❑ 421 VEHICLE FUELING STATION ❑ ® ❑ ❑ ' 422 NOT USED ❑ _ ❑ ❑ ❑ 504 NOT USED ❑ 1:1 1­71 F-1 PS-1 CD-1 ! 505 CARPORT ❑-- - _ 171 ❑ ® CT-5 CT-3 _ PS-1 P-3 _ PS-1 -- ❑ ❑ ❑ ❑ - ❑ ❑ ❑ ❑ CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable ' CT-2 Steel Frame PS-2 Major Damage CD-2 Major Deficiencies P-2 High Reuse Potential CT-3 Concrete PS-3 Special Study Reqd. P-3 Possible Reuse CT-4 CMU P-4 Salvageable Equipment CT-5 Slab on Grade BLDG—SUR.ASS/A93—B17 PAGE 5 OF 7 I BUILDING SURVEY/JOB NO. 9335.01 /DATF ?—?8-9A GOULD ARCHITECTS I Bldg. Name Building Types Existing Conditions No. Military Support_Residential Construct Special Site Architect Struct Plumbing Fire HVAC Electrical ' COMMON sPECRC Type Features Protection 506 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- 507 FIRE HOSE HOUSE ❑ ® ❑ 171 CT-1 PS-1 PS-2 508 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- I ' 509 FIRE HOSE HOUSE ❑ ® ❑ ❑ CT-1 PS-1 PS-2 -- -- -- -- -- 510 FAMILY HOUSING ❑ El El ® CD-1 CT-1 CT-5 PS-1 PS-1 P-3 PS-1 -- PS-1 PS-1 517 FAMILY HOUSING ❑ ❑ ❑ ® CT-1 CT-5 PS-1 PS-1 -- PS-1 -- PS-1 PS-1 18 i El 5 NOT USED ❑ ❑ El1 El El ❑ ❑ 599 NOT USED ❑ ❑ ❑ ❑ 600 NOT USED ❑ ❑ ❑ ❑ 601 NOT USED ❑ ❑ ❑ ❑ 602 NOT USED ❑ ❑ ❑ ❑ 603 NOT USED ❑ ❑ ❑ ❑ ' 604 NOT USED ❑ ❑ ❑ ❑ 605 NOT USED ❑ ❑ 0 ❑ 606 NOT USED ❑ ❑ ❑ ❑ 607 NOT USED ❑ ❑ ❑ ❑ 608 NOT USED ❑ _ ❑ ❑ ❑ I ' y y ❑ ❑ ❑ ❑ 699 NOT USED ❑ 171 ❑ ❑ ' 700 COMM TRANS/RCVR ❑ ® ❑ ❑ NOT ACCESSIBLE ❑ ❑ ❑ ❑ i ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1 ❑ CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable CT-2 Steel Frame PS-2 Major Damage CD-2 Major Deficiencies P-2 High Reuse Potential CT-3 Concrete PS-3 Special Study Reqd. P-3 Possible Reuse CT-4 CMU P-4 Salvageable Equipment CT-5 Slab on Grade BLDG—SUR.ASS/A93-817 PAGE§_OF 7 BUILDING SURVEY/JOB NO. 9335.01 ,/DATF ?—? —94 GOULD ARCHITECTS Bldg. Name Building Types Existing Conditions No. Military Support Residential Construct Special Site Architect Struct Plumbing Fire HVAC Electrical COMMON SPECIRC Type Features Protection 701 NOT USED 1771 D ❑ ❑ 710 NOT USED ❑ ❑ ❑ El NOT A CESSIBLE ' 711 HEATING FUEL OIL STG ❑ 1Z ❑ ❑ NOT A CESSIBLE 712 SAN SEWER MAIN ❑ ® ❑ ❑ NOT A CESSIBLE 713 WATER TANK STORAGE ❑ ® ❑ ❑ NOT A CESSIBLE 714 NOT USED ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ' 721 NOT USED ❑ ❑ ❑ ❑ 722 SENTRY HOUSE ❑ ® ❑ ❑ NOT ACCESSIBLE 723 NOT USED ❑ D 171 724 NOT USED ❑ ❑ ❑ ❑ ' 725 SEWAGE SEPTIC TANK ❑ ® ❑ ❑ NOT ACCESSIBLE 726 NOT USED ❑ ❑ D ❑ ' 779 NOT USED ❑ ❑ ❑ ❑ 880 FUEL STORAGE TANK ❑ ® ❑ ❑ 881 NOT USED ❑ ❑ ❑ ❑ 882 NOT USED ❑ ❑ ❑ ❑ 883 NOT USED ❑ ❑ ❑ ❑ 884 WATER STORAGE TANK ❑ ® ❑ ❑ ❑ ❑ ❑ ❑ El a El ❑ [� ❑ ❑ ❑ ❑ 1 ❑ ❑ CONSTRUCTION TYPES PHYSICAL STATUS CODE DEFICIENCIES USE POTENTIAL CT-1 Wood Frame CT-6 Raised Floor PS-1 Minor Damage CD-1 Minor Deficiencies P-1 Functionally Obsolete/Unrepairable CD-2 Damage or — CT-2 Steel Frame PS-2 Major Major Deficiencies P 2 High Reuse Potential 9 1 CT-3 Concrete PS-3 Special Study Regd. P-3 Posssible Reuse CT-4 CMU P-4 Salvageable Equipment CT-5 Slab on Grade BLDG—SUR.ASS/A93—B17 PAGE2—OF 7