Loading...
HomeMy Public PortalAboutWell #9 Tank Project Order #9Director Brona D. Steele TO: FROM: DATE: COPY: SUBJECT: City of Crestview Deparbtnent of Public Services 715 Fenton Boulevard North Crestview, Florida 32536 PROJECT MEMORANDUM Elizabeth Roy, City Clerk Fred Cook, City Engineer March 25, 2014 Tuesday File Well #9 & Tank Project Change Order #9 Here is Change Order #9 on this any questions, let me know. Please process this for approval Contractor. Thank -you. project. Carlos has signed it and then give back to me for Telephone No. (850) 682-6132 Fax No. (850) 682-7359 E-Mail: fredcook@citvofcrestview.orq in Wayne's absence. If you have returning to the Engineer and I C Via E-mail TETRA TECH March 18, 2014 Tt No. 200-08540-12001 Wayne Steele Public Services Director City of Crestview 715 N. Ferdon Blvd. Crestview, Florida 32536 Subject: Old Bethel Road Part I Change Order No. 9 Dear Mr. Steele: Enclosed, please find Change Order No. 9 with backup information from Speegle Construction, Inc. (Speegle). This Change Order encompasses both costs and credits to the Contract Change Order No. 9 amounts to an addition of $5,106 to the Total Contract Price and no days added to the Total Contract Time. We have reviewed the proposed Change Order provided by Speegle and find it acceptable. Should you have questions or need additional information, please feel free to contact me. Timothy A. Vanderwalker, PE Project Manager Cc: Michael Bomar, PE, Tetra Tech Fred Cook, PE, City of Crestview Tetra Tech, Inc 12815 Emerald Coast Parkway, Suite 110, Destin, FL 32550 850.837.9278 Fax 850.837.7269 www tetratech com P:\2011\Crestview Well and Tank \Construction \Review -Approval \ContractorCOs \Part I\Part I Change Order No. 9.docx. SCONSTRUCTION INC. c G<-"a24.9v PEEGLE March 17, 2014 Mr. Tim Vanderwalker Tetra Tech 12815 Emerald Coast Pkwy, Suite 110 Destin, FL 32550 Dear Sir, Speegle Construction, Inc. I Tel. (850) 729-2484 210 Govemment Avenue Fax: (850) 729-1993 Nicevllle, Florida 32578 www speegleconstruction.com Dan Carruth Project Manager RE: Crestview Well No 9 COR 1002-009 - Add Underground Sch 40 PVC Discharge Line from Bldg to Precast Box in Swale Speegle Construction, Inc. respectfully submits the attached the following estimate associated with providing conveyance of water from the discharge line, which is currently stubbed outside of the pump house to the swale. Scope of work is to provide an 8" Sch 40 PVC line from the building to a concrete structure in the swale. This discharge line will be tumed down from it's existing point using a DIP 90, then transitioning to Sch 40 PVC and going below grade, then turning towards the swale using a Sch 40 90 Four (4) Sch 40 45 degree bends have been included in order to angle towards the swale (while avoiding the splashblock) and to to allow for the swale slope. The concrete structure will be a 2'x2'x3' deep precast unit with non -traffic rated grate as well as a "sump" in the bottom to allow for drainage of standing water. This structure will be placed on a bed of 57 stone, which will serve as both a foundation for the structure as well as provide drainage underneath the sump (which will be filled with washed gravel). The top of the grate will be set such that the east and west sides will be 12" above the ground (i.e. flush with the 12" thick rip rap). The filter cloth below the rip rap will be toed -in 12" deep on all sides of the structure Also included are provisions to reconfigure the air release valve PVC piping to penetrate the CMU wall; a credit for the use of a 1/4" sensing line (in lieu of 1/2"); and the electrical costs associated with upgrading the chlorine booster pump. This estimate is based on our best understanding of the changes that are necessary to complete the scope of work. In the event that additional work is required due to unforseen conditions or impacts to other systems, Speegle reserves the right to revisit this estimate. This estimate does not include any provisions for additional time which may be required due to long lead times on the precast structure and PVC materials package. If the procurement of these items results in the necessity for a time extension, Speegle reserves the right to request such time and fully expects that such time will be granted. Total estimate $ 5,106 Should you require any additional information, please do not hesitate to contact Dan Carruth at 850-729-2484 or email dcarruth@speegleconstruction.com cc: file Sincerely, J j�- Dan Carruth Project Manager SECTION 00843 CHANGE ORDER FORM Project: City of Crestview Part I - Well No. 9 and Elevated Storage Tank DATE OF ISSUANCE: EFFECTIVE DATE: OWNER'S CONTRACT NO.:200-08540-12001 CHANGE ORDER NO. 09 CONTRACTOR:Speegle Construction, Inc. ENGINEER: Tetra Tech The following changes are hereby made to the Contract Documents: CHANGE IN CONTRACT PRICE: Original Contract Price $ 1,965,660.00 CHANGE IN CONTRACT TIMES: Original Contract Times Substantial Completion: 12/23/2013 Ready for final payment: + 30 Days days or dates Net changes from previous Change Orders No. 1 to No. 8 $ 61,095.00 Net change from previous Change Orders No. 1 to No. 8 112 days Contract Price prior to this Change Order $ 2,026,755.00 Contract Times prior to this Change Order Substantial Completion: 4/ 014 0/ Ready for final payment: y s days or dates Net Increase (AeeFeese) of this Change Order $ 5,106.00 Net Increase (fleeFesse) of this Change Order 0 days Contract Price with all approved Change Orders $ 2,031,861.00 '/ Contract Times with all approved Change Orders Substantial Completion: 4/14/2014 Ready for final payment: + 30 Days days or dates MAD/slm/specs/s-1 /00843 Tt#200-08540-12001 00843-1 050412 FOR CONSTRUCTION INCLUDING ADDENDUMS 1, 2, 3, 4 & 5 1 /29/2013 CHANGES ORDERED: I. GENERAL This change order is necessary to cover changes in the work to be performed under this Contract. The General Conditions, Supplementary Conditions, Specifications and all parts of the Project Manual listed in Article 1, Definitions, of the General Conditions apply to and govern all work under this change order. Change Order No. 9 II. REQUIRED CHANGES: Add an 8" underground Sch 40 PVC discharge line from the well pump building to a concrete structure in the swale. Reconfigure the air release valve discharge piping to penetrate the CMU wall. Credit for the use of 1/4" sensing line in lieu of 1/2". Electrical costs associated with upgrading the chlorine booster pump. III. JUSTIFICATION: IV. PAYMENT: MAD/slm/specs/s-1 /00843 Tt #200-08540-12001 00843-2 050412 FOR CONSTRUCTION INCLUDING ADDENDUMS 1, 2, 3, 4 & 5 1 /29/2013 V. APPROVAL AND CHANGE AUTHORIZATION: Acknowledgments: The aforementioned change, and work affected thereby, is subject to all provisions of the original contract not specifically changed by this Change Order, and, It is expressly understood and agreed that the approval of the Change Order shall have no effect on the original contract other than matters expressly provided herein. Change Order Request by: Change(s) Ordered by: RECOMMENDED BY: APPROVED BY: City of Crestview, Florida (Owner) MAD/s1m/specs/s-1/00843 Tt #200-08540-12001 ACCEPTED BY: END OF SECTION 00843-3 050412 FOR CONSTRUCTION INCLUDING ADDENDUMS 1.2. 3.4 & 5 1 /29/2013 REQUEST for CHANGE ORDER SUMMARY ARCH RFPA SCI RCN/ QUOTE DATE DESCRIPTION: Add Underground Sch 40 PVC Discharge Line from Bldg to Precast Box in Swale REASON FOR CHANGE' Request by Owner 1002-009 3/17/2014 DIV SCOPE DESCRIPTION NOTES LABOR MATL EQUIPT SUBCONT SCI COSTS TOTAL SUBCONTRACTED TOTAL GRAND TOTAL 1 General Conditions $ - $ - i - $ - $ - 6 - 6 - 2 Sftevoork 8 Demolition $ 1,208.18 $ 1,935.24 6 75.00 $ 75 00 $ 3,218.42 i 75.00 $ 3,293.42 3 Corxxete $ - $ - 9 - $ - $ - $ $ - 4 Masonry 6 56.25 $ 85.00 $ 25.00 6 - 9 166.25 $ - $ 166 25 5 Steel i - $ - $ - $ - $ - $ - $ - 6 Carpentry, Wood 8 Plastic i - $ - $ - $ - $ - $ - $ - 7 Thermal 8 Moistve Protection $ - $ - 6 - 9 - $ - $ - $ - 8 Openings $ - $ - $ - $ - $ - $ - 6 - 9 Finishes $ - 6 - $ - $ - $ - $ - $ - 10 Specialties $ - $ - $ - $ - $ - 6 - $ - 11 Equipment b - $ - 6 - 6 - 6 - $ - $ - 12 Fur ishirge $ - $ - 6 - $ - $ - $ - $ - 13 Special Construction $ - $ - $ - $ - $ - 6 - $ - 14 Hoisting 6 Conveying i - 6 - $ - $ - $ - $ - $ - 15 Fire Spnriders $ - $ - $ - $ - $ - $ - $ - Pluribing $ - 6 - $ - $ (67.18) $ - $ (67.18) $ (67.18) HVAC 6 Controls $ - $ - 6 - $ - i - $ - 6 16 Elednoal $ - $ - i - $ 287.00 $ - $ 287.00 9 287.00 17 Commissioning $ - $ - $ - 6 - $ - $ - $ - SubTotals Payroll Burden Sales Tax Sub Bond SubTotals General liability Inman:a Property (Builder's Risk) Insurance P 3 P Bond Gross Receipts Tax (City Bus LIc) SUBTOTAL Overhead/Profit Overhead/Profit SUBTOTAL GRAND TOTAL Extsnded General Overhead $ 1,284.43 $ 2,020.24 9 100.00 $ 294.82 9 3,384.67 9 294.82 $ 3,679.49 45% $ 568.99 : ' 1 1 K_ ( 4 - $ 668.99 $ - $ 668.99 6% =-'=-- = ',_- _ _ $ 121.21 $ $ 127.21 $ - $ 127.21 000% _.,z�_-:.-.,-'._,`>-.=-_C-�,: -------_-`_--.'_` $ - $ - $ - 9 - 9 1,833.42 $ 2,141.45 $ 106.00 $ 294.82 $ 4,080.87 $ 294.82 $ 4,376.69 0 4200% of Subtotal of Subtotal of Subtotal $ 17.14 6 1.24 $ 18.38 0.6500% $ 26.53 $ 1.92 $ 28 44 1.0000% $ 40.81 6 2.95 6 43 76 0.0000% 6 - $ - $ - i 4,165.34 $ 300.92 $ 4,446.27 15.03% $ 624.80 $ - 6 624 80 5.00% $ - 6 15.05 $ 15 05 $ 4,790.16 $ 316.97 $ 6,106.12 9 4,790.16 9 316.97 f 6,106.12 $ - $ - 9 - $ - $ - $ - $ 4,790 $ 316 $ 6,109 Time Extension 'This Proposal ls for only the work Identified by the above change description. • See reservation of rights language on the Detail backup Calendar days 3' DESCRIPTION: REASON: DETAIL PROPOSED CHANGE ORDER ESTIMATE DIRECT COST ASSOCIATED WITH CHANGE ORDER Add Underground Sch 40 PVC Discharge Line from Bldg to Precast In Swale ARCH RFP SCI RCO* Quoit DATE 1002-009 Request by Owner 3/17/2014 CODE SCOPE DESCRIPTION QUANT units L / U.P. -. LABOR M / U.P. MAIL EQUIPMENT SUBCONT TOTAL 1 GENERAL CONDITIONS Project Manager 33% 0.00 wks 1,730.00 $ - $ - $ - Project Managers Truck/Insurance/Gas 33% 0.00 months $ - 650.00 $ - $ - Superintendent 33% 0.00 wks 1,550.00 $ - $ - $ - Superintendent's Tnx.lc/Insurance/Gas 33% 0.00 months $ - 650.00 $ - $ - Office Trailer 0.00 months $ - 200.00 $ - $ - Superintendent Cell Phone 33% 0.00 months $ - 150.00 $ - $ - Temp Toilets 0.00 months $ - 150.00 $ - $ - Asbuilt documentation 0 HRS 25.00 $ - $ - $ - RFP Preparation 0 HRS 43.25 $ - $ - $ - Temp Utilities 0.00 months 50.00 $ - $ - $ - Backhoe $ - 75.00 $ - $ - Loader/Dozer $ - 150.00 $ - $ - Copying & Specifications $ - $ - $ - Mail & Express Postage $ - $ - $ - Layout & Field Engineering $ - $ - $ - Crane & Hoisting $ - $ - $ - Schedule Study & Modification $ - $ - $ - Prepare Fragnet $ - $ - $ - Material Handling Equipment $ - $ - $ - Safety $ - $ - $ - Clean-up & Debris Handling $ - $ - $ - Dumpster Pulls $ - $ - $ - Equipment Rental $ - $ - $ - Trucking & Hauling $ - $ - $ - Small Tools $ - $ - $ - Other $ - $ - $ - $ - $ - $ - Division 1 Subtotal $ - S - $ - $ - $ - 2 SITEVI/ORK & DEMOLMON 8" 90 - DIP 1.5 HRS 55.50 $ 83.25 $ 207.00 $ 290.25 Extra (4th) 45 to avoid undermining splash pad 0.5 HRS 55.50 $ 27.75 S 69.93 $ 97.68 Discharge Pipe (PVC) Mtls pkg 6 HRS 55.50 $ 333.00 $ 935.00 $ 1,268.00 Trench and Baccfill, Hand Dig 4 HRS 43.50 $ 174.00 $ - $ 174.00 Thrust Blocks (if desireq 4 Ea 55.20 $ 220.80 $ 50.00 $ 270.80 PVC Glue 1 Can $ - 18.00 $ 18.00 $ 18.00 Marking Tape 0.25 Roll 55.50 $ 13.88 $ 32.00 $ 45.88 7x7x3' deep Precast Structure 3 VF 100.00 $ 300.00 $ 590.45 $ _ 50.00 $ 940.45 57 Stone Base, 1 CY 1 HRS 55.50 $ 55.50 32.86 $ 32.86 $ 25.00 $ 113.36 Paint Additional Piping 1 LS $ - $ - $ 75.00 $ 75.00 Division 2 Subtotal $ 1,208.18 $ 1,935.24 $ 75.00 $ 75.00 t 3,293.42 3 CONCRETE 0 EA 0.00 $ - $ - $ - $ - $ - $ - Division 3 Subtotal $ - $ - $ - $ - $ - 4 MASONRY & STONE Unitstrut/brackets/fasteners/misc PVC fittings 1 LS 75.00 $ 75.00 S 75.00 Cut 2.5" hole in block and cleanup 2 HRS 25.00 $ 50.00 $ - $ 25.00 $ 75.00 Caulk Thru-wall pipe 0.25 Hrs 25.00 $ 6.25 10.00 $ 10.00 $ 16.25 Division 4 Subtotal $ 56.25 $ 85.00 $ 25.00 $ - $ 166.25 5 STEEL & METALS EA $ - $ - $ - $ - $ - $ - Division 5 Subtotal $ - S - S - $ - $ - 6 WOOD & PLASTICS $ - $ - $ - $ - $ - $ - $ - Division 6 Subtotal $ - S - S - $ - $ - 7 THERMAL & MOIST PROTECT $ - $ - $ - $ - $ - $ - Division 7 Subtotal $ - $ - $ - $ - $ - 8 OPENINGS $ - $ - S - $ - $ - $ - Dlvision 8 Subtotal $ - $ - $ - $ - $ - DESCRIPTION: REASON: DETAIL PROPOSED CHANGE ORDER ESTIMATE DIRECT COST ASSOCIATED WITH CHANGE ORDER Add Underground Sch 40 PVC Discharge Line from Bldg to Precast In Swale ARCH RFP SCI RCO* QUOTE DATE 1002-009 Request by Owner 3/17/2014 CODE SCOPE DESCRIPTION QUANT units L / U.P. LABOR M / U.P. MAIL EQUIPMENT SUBCONT TOTAL 9 FINISHES $ - $ - $ - $ - $ - $ - Division 9 Subtotal $ - S - $ - $ - $ - 10 SPECIALTIES $ - $ - $ - $ - $ - $ - Division 10 Subtotal $ - $ - $ - $ - $ - 11 EQUIPMENT $ - $ - $ - $ $ - $ - Division 11 Subtotal $ - $ - $ - $ - $ - 12 FURNISHINGS $ - S - $ - $ - $ - $ - Division 12 Subtotal $ - $ - $ - $ - $ - 13 SPECIAL CONSTRUCTION $ - $ - $ - Division 13 Subtotal $ - $ - $ - S - $ - 14 HOISTING & CONVEYING $ - $ - $ - $ - $ - $ - Divislon 14 Subtotal $ . - $ - S - $ - $ - 15 FIRE PROTECTION $ - $ - $ - S - $ - $ - Divislon 15 Fire Subtotal $ - $ - $ - $ - $ - 15 PLUMBING Credit for use of 1/4" sensing line in lieu of 1/2" $ - $ - $ (67.18) $ (67.18) $ - $ - $ - Division 15 Plumb Subtotal $ - $ - $ - $ (67.18) $ (67.18) 15 MECHANICAL & HVAC $ $ - $ - $ - $ - $ - $ - Division 15 HVAC Subtotal $ - $ - S - $ - $ - 16 ELECTRICAL Electrical changes associated with chlorine booster pump upsizing $ - $ - $ 287.00 $ 287.00 $ - $ - $ - $ - Division 16 Subtotal $ - $ - $ - $ 287.00 $ 287.00 17 COMMISSIONING $ - $ - $ - $ - $ - $ - Division 17 Subtotal $ - $ - $ - $ - $ - SubTotals $ 1,264.43 MOM $ 2,020.24 $ 100.00 $ 294.82 $ 3,679.49 i a w Nar,ama 1a•••••1 u 1ar4 3 2 ap Z fn i m m; vDm mg ZOy o° O Z L Za 5N m e 4 n k 4 0 6 005 roLL335 61f1QNVLS 1JOi Y LYWIAN,W al 335- G c3W n MIS .063111113103'D 31Y80 ONLL51Q akin 1.1.10nAVLI sw I ad, awn, aw vw. r NLN1035,340.1 al saWS +�IM+n ne ,i _ /-01+0SI16 3iw3J lNW .1111NO11Ar11 Galan Maya 103113/0d iO 3003 110Y11351103NV5 1V OVOY 130130 010 ONOIV NlYON OS 0111'001311 ONV 03n0e3 V 30 01 ..1143A1110 030010110 NNLN 031V001 NOM ONIISIX3 330N 1 =1 Inn INOr.1rO / v w %soa 531f130110MY30 POLL . U15 13a13or'/ Noe3a 1004 o�ix o311r311n 10o:owl lf 3 d. arras •n DELL wvo,e / v ._ la 1.S 2IazUr11311sannaono la"a3a1:.X30N1 / //,� 1<fZ Ya•la•�ONq Yi1H % / noiZous ia Nad autos al NOIe 31wnYl drYpK 11 Das N.M. NOW aMs'ia%O.! 01 . NSIO 551•00 NINA r IZ,5741 3 ZI a0Z l3 Z IOZr 1NI00 10Y1NOJ / Snomoita3d5 .011,DW1113.11N:'. a0 91‘' v aMnY3d UNaal 1U111 -k JII/.c drwn.Q11 + ayr+l n lO�NV /VJ�YU31 / aY`WoCI••d/ / nOLLV�ro l NCLL03nJ 31 NCIOIY3lOW Onv Can anlVaazraa Lal'ON XlOv1 1131411311110 N0i30 ION REM MYoL Y3 N31lNNa Xd Onr SONYAITyrol F N1W Wr NW] a a UAL • 30Ai it F, -•• �.�,vl,3ala Ovule Nldao n•laaWnil • mwliJli.J da MOON,. ! 113d IONOi11101e jaw& 4.61. K Ga • N1.0a111 Cad WALLS 113YOn00� x x+n lniq +lanwx NI 110IN1 a%3NrrgS 0 ALNOOJ V5001VN0 NO11 01400 A%.3 Oi N510 SSVYQ FILM 1fa HOCS 3 a013 I WLr1NN0YlO11Y30 3.1.112 NAOS NOL MIL A1310W0f011dI1VWM V 03OOl MYVON3Q 1VNgL00V 310N SaJaLaa V LLVJo�vlrri� O011:01,001,9 YJ11001N0 W1.1,11W011VA MS T. TaOLLVna a l 151 Nu3N0303N a03S1V 133a an 1 31N;3a�NS3o i0,0CWd 3 1W it ITC �roH%a�3 0103053 3a Tna OVOr T3W3a Qp ONO,r Gr3�03aMuP311V OW MIL .aI NMaDa,.. 1 N4Vn Man a.<anl� 1,. SION Calah, 10Nuru Nn,mm103Y �•.�.•� @13031 ONLLHYId w mess -xvJ.,s-momrom.i i IA � ,:.F.1.433514F H331 V11131 eoz s19 -3.10 •14.4. re aF.w.:oriumee<LaL ,f Fn. W34 .1000llVn .11014 )1103S OMd NVId 1N3Wd11103 3S110Hll3M NIV1'1 N31VM MON 13H1311 010 II Ind -SNfd13A011dN 1131SAS N31VM 11161NYo CAIp �1 F 1 r 1 L1) O r 1 13S NO110rI iL4NOO LIOA 3Sv31311 WALL PENETRATION IIYII U oa Q m 1� 0.1,.143snaara43.,.13.,12.,s3,d<aiwomwriancrem.....e,. N.«zMGR= 1 SOUTHEASTERN PIPE & PRECAST, INC 2900 N. HIGHWAY 95A CANTONMENT, FL 32533 OFFICE: (850) 587—PIPE (7473) FAX: (850) 587-3026 r I1PCR 12" diameter sump for drainage of water SECTION VIEW A XX d 4 I— • .4 XX 6" a • d• VIEW 24" 2" • 44" TOP EDGE CHAMFER i XX" 2'x2' RISER SECTION (APPROX. WI: X,XXX Ibsf) XX" 2'x2' BASE SECTION (APPROX. WT: X,XXX Ibsi) d 1 24" I 6' b • 6" 24" 2 NOT TO SCALE DIMENSIONS SHOWN ARE SUBJECT TO SUGHT VARIATIONS DURING PUNT PRODUCTION SECTION VIEW B XX • • XX a • tl • 6" • tl• • d tl 6" 24" tYz 148"x48"x20" deep 57 Stone bed for drainage. SPECIFICATIONS AND NOTES 1. CONCRETE: 4,000 psi 2. REINFORCEMENT: AREA 0.20 WWF FOR WALLS/SLAB 3. UFT DEVICES: 1.5" PVC UFT HOLES FOR SECTIONS 4. JOINT SEALANT: 1.25" BUTYL SEALANT "RAMNEK" 5. CASTING: USF 6217 GRATE 6. LOAD RATING: LIGHT DUTY 7. STEPS: NONE TOP ELEVATION: XXX.XX THROAT ELEVATION: XXXXX DIRECTION (DEGREE) PIPE SOLE/TYPE HOLE SIZE (HLOCKOU'T) HOLE RAISE 8. COATING: NONE 9. STRUCTURE MEETS ASTM C-913 INVERT ELEV (OUT): XXXXX INVERT ELEV (IN): XXX.XX XXX XXX XXX XXX XXX XXX XXX XxX 10. XXX 11. XXX INVERT ELEV (IN): XXXXX INVERT ELEV (IN): XXX.XX INVERT ELEV (IN): XXX.XX INVERT ELEV (IN): XXX.XX XXX XXX XXX XXX 12. XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX XXX PLAN/PROFILE SHEET: XXX DETAIL SHEET: XXX STATION NUMBER: XXX JOB NUMBER XXX ENGINEER/CONTRACTOR APPROVAL CONTRACTOR/CONTACT JOB INFORMATION/ LOCATION STRUCTURE DATE/PAGE d XXXXX XXXXX XXXXX XXXXX XXXXX 2'x2' BOX XXXXX XXXXX li Dan Carruth From: Kurt Lauw <kurt@southeasternpipe.com> Sent: Thursday, March 06, 2014 11:51 AM To: Dan Carruth; Kenny@southeasternpipe.com Subject: 2'x2' Quote Dan - Per our conversation, please see below for some pricing ideas. Thanks (0'-2') 21x2' Area Drain w/ USF 6217 Grate - $316.35 (0'-3') 2'x2' Area Drain w/ USF 6217 Grate - $390.45 Partial Delivery Charge to Crestview - $200 Kurt Lauw - Certified Draftsman 2900 N Hwy 95A - Cantonment, FL - 32533 o: 850.587.7473 - f: 850.587.3026 www.southeastempipe.com Southeastern Pipe 8 Precast, Inc. FEI-SANTA ROSA BEACH, FL #1204 fdFERGUSON 133 SHANNON LANE ENTERPRISES, SANTA ROSA BEACH, FL 32459 INC: Deliver To: joseph.klimaefergusoa.com From: Joseph Klima Comments: 16:24:12 MAR 06 2014 Bid No • B222447 Bid Date • 03/06/14 Quoted By.: JAK Customer: SITE d UTILITY SOLUTIONS INC CITY OF CRESTVIEW WELL #9 PO BOX 749 NICEVILLE, FL 32588 Cust PO#...: FEI-SANTA ROSA BEACH, FL #1204 Price Quotation Phone : 850-622-9166 Fax :850-622-9168 Page # 1 OUSt 850-729-2484 Terms • NET 10TH PROX Ship TO: SITE 8 UTILITY SOLUTIONS INC CITY OF CRESTVIEW WELL #9 PO BOX 749 NICEVILLE, FL 32588 Job Name: DISCHARGE PIPE Item Description P40BEPX20 P80S4X P40S9X PFP80VSSFX PFP80VSSFX AFT350PX FNWNBGS41 RF8X FPPXU MJ9LAX MJ4LAX SSLDE8AP — PVC OPTION — 8X20 FT PVC S40 BE PIPE 8 PVC S80 SXS 45 ELL 8 PVC S40 SXS 90 ELL 8 PVC S80 SOC FLG 8 PVC S80 SOC FLG SUBTOTAL — DUCTILE OPTION --- 8 CL350 CL DI FASTITE PIPE 8 304SS 150# RR FF 1/8 FLG PKG 8X6'0 FLGXPE CL BT DI SPL 8 MJ C153 90 BEND UA 8 MJ C153 45 BEND UA 8 DI WDG REST "ONELOK W/A SUBTOTAL Quantity Net Price UM Total 80 750.000 C 600.00 3 69.930 EA 209.79 1 52.840 EA 52.84 1 36.310 EA 36.31 1 36.310 EA 36.31 80 21.450 FT 1716.00 1 33.340 EA 33.34 1 370.750 EA 370.75 1 235.200 EA 235.20 3 190.400 EA 571.20 4 0.000 EA 0.00 2,926.49 Net Total: Tax: Freight: Total: $0.00 Quoted prices are based upon receipt of the total quantity for immediate shipment (48 hours). SHIPMENTS BEYOND 48 HOURS SHALL BE AT THE PRICE IN EFFECT AT TIME OF SHIPMENT UNLESS NOTED OTHERWISE. Seller not responsible for delays, lack of product or increase of pricing due to causes beyond our control, and/or based upon Local, State and Federal laws governing type of products that can be sold or put into commerce. This quote is offered contingent upon the buyer's acceptance of Seller's terms and conditions, which are incorporated by reference and found either following this document, or on the web at httpi/wolseleyna.con terms conditionsSale.html. Govt Buyers: All items are open market unless noted otherwise. LEAD LAW WARNING: It is illegal to install products that are not "lead free" in accordance with US Federal or other applicable law in potable water systems anticipated for human consumption. Products with •NP in the description are NOT lead free and can only be installed in non-pofable applicabons. Buyer Is solely responsible for product selection. 02/25/2014 10:21 18508632136 BEARDEN CONSTRUCTION PAGE 01/04 Bearden Construction Company, Inc. ELECTRICAL. CONTRACTORS Industrial To: Mr. Dan Carruth Speegle Construction Co. Inc. Re Crestview Well #9 Commercial pale Line February 2S, 2014 We propose to make the following changes to accommodate the chlorination pump on the above project. Changes included will be changing the breaker to a 30/2, changing the overload module to a LRD 16, and changing the receptacle to a NEMA L6-30R. (Existing conduit and wiring will be reused.) Total costs of these changes ar Our pricing sheets are attached for your review. If you should have any questions please call Richard Reeves or the under signed. Earl Bearden, CEO Accepted: Date: Telephone: 850-863-2131 - P.O. Box 849 • Fort Walton Beach, Florida 32549/0849 Fax* 850-863-2136 • E-mail: Richard@beardenelecMc.00m - State Cert. Elect. Contr. #EC0000327 Nuetat map. ASIM Iaege foam. puts tmuel very dre a =El 44t1 Mtn...drag �tl•�8 •I4e1 nv iKR .WM0 S 11t§..v0.20 • men 1:140 1 .G-Szao ard ONSil0 �odaa ala 14183 lusPyTIS IVOT VTOL/SLAB 9ETLE98058T V0/LO 39Vd 0 u u 1< D 6DI SS A ►i1S 02 Af OPCP Ya CO L �+1 i1!!! CDT NOLIAB121250730Y110AW 07 aa+.l SKI CPI lq1.4u4 Doij.Y.0 ALry Kowa OtllQV1nlS OL alsMW Dop+M 11!'1►1 1 ...Dv son DD'1 q OZ UK •.CK 27 up MP 29 31 NTS 02 3/ D7 DS 3 Co L mem ss.pl;p17 uoics *WC CC* NMAM 07 aO WV 2Orn11L zs NOLDIONI S/O30 Y170A1H01 000-0000L a+�4 *Sel 091 SD SNOLLION00 7iRl3N30 if i► 2► coo 2► aV D072 as DS'l solavrt GSS N1�9 .O.Clos3 DI 011.1,101 %o.w MOW {aneinf goo. lunow, Lmuuy 1a0 Nan 1laouy Nwo 4a0 At INa;a1 SNOIIlON00 7YY3/NJd0 Wei PTea/sa/se 9etiae99e5eT ammo; T. m w0tuuaap you 6/I !NM kuISM410 uoda}L alsums3 Ptxpue2g 7t!! "00 7SCrOn MAI VOW 1 a Estimate Totals 4111212 spA 10 60/09 39Vd NOLIMMISNOD Naldne 9ETZE990581 TV4IIT 6TBU5ZA0 .f , Director Brona D. Steele City of Crestview Department of Public Services 715 Ferdon Boulevard North Crestview, Florida 32536 INTEROFFICE MEMORANDUM PUBLIC SERVICES DEPARTMENT TO: Wayne Steele FROM: Fred Cook DATE: March 19, 2014 Wednesday COPY: File SUBJECT: Well #9 & Tank Project Change Order #9 Telephone No. (850) 682-6132 Fax No. (850) 682-7359 E-Mail: fredcook@citvofcrestview.orq Here is a change order to add a hard pipeline for the well pump -off discharge, plus a couple small items to adjust the contract. The plans did not show a pump -off line in them, so we had to discuss this in our last meeting and decide on what to do. I have attached some additional paperwork to show the decision process. If there are any questions, let me know. Please process this to Ms. Roy. JUC a Cook, Fred From: Cook, Fred Sent: Monday, March 17, 2014 7:32 AM To: 'Bomar, Michael' Cc: Vanderwalker, Timothy; Knecht, Vincent; McLeod, Nick Subject: RE: Well No. 9 Pump Off Michael: We choose Option A — buried PVC pipe to box located in the rip -rap area. You need to cut a hole through the bottom of the concrete box so water can freely drain out and not sit in it, draw mosquitoes. Place stone under it to facilitate support and drainage through the hole (typical drainage design). Fred B. Cook, P.E. City Engineer City of Crestview, Florida (850) 682-6132, ext. 109 From: Bomar, Michael[mailto:michael.bomar@tetratech.com] Sent: Friday, March 14, 2014 9:15 AM To: Cook, Fred Cc: Vanderwalker, Timothy Subject: Well No. 9 Pump Off Fred, as a follow up to our meeting last week, we requested that Speegle provide two estimates to add piping to the project to direct the well pump off discharge away from the north side of the building. Option A is for about $5000 and includes buried pvc piping from the building to the swale with a discharge via a bubble -up structure in the swale or discharge from the pipe to the tank overflow flume. Option B for about $4000 includes ductile iron pipe fittings, a quick connect adapter, and flex hose that could be connected and routed to the swale or simply onto the asphalt parking lot to sheet flow down to the swale. Option B is higher than I quoted on the phone yesterday because I wasn't thinking about the costs for the fittings but $700 would be deducted from the $4700 cost (see their footnote #2) to get to the $4000. We are currently $20k below the contract amount City Council approved for this project (we're $80k below budget if you include the $60k for well casing approved by Council). I'm attaching some correspondence from Speegle for your information. Speegle would like some direction on this matter as soon as we can provide. Michael B. Bomar, P.E. N ice President michael.bomarOtetratech.com Tetra Tech ( IT 12 SOIT"1'IONS �� �� w.I el ratech.com 1r • • SCONSTRUCTION INC. -IA l i I PEEGLE C (K.-002.10 Speegle Construction, Inc. Tel. (850) 729-2484 210 Government Avenue Fax (850) 729-1993 Nicevllle, Florida 32578 www speegleconstruction com March 13, 2014 Dan Carruth Project Manager Mr. Tim Vanderwalker Tetra Tech 12815 Emerald Coast Pkwy, Suite 110 Destin, FL 32550 Dear Sir, RE: Crestview Well No. 9 COR 1002-009 - Add Underground Sch 40 PVC Discharge Line from Bldg to Precast Box in Swale (Option A) OR Add Flexible Discharge Hose (Option B) Speegle Construction, Inc. respectfully submits the attached two change order proposal options (Option A and Option B) associated with providing conveyance of water from the discharge line, which is currently stubbed outside of the pump house to the swale. Option A is to provide an 8" Sch 40 PVC line from the building to a concrete structure in the swale. This discharge line will be turned down from it's existing point using a DIP 90, then transitioning to Sch 40 PVC and going below grade, then turning towards the swale using a Sch 40 90. Three (3) Sch 40 45 degree bends have been included in order to angle towards the swale and to to allow for the swale slope. The concrete structure will be a 2'x2'x3' deep precast unit with non -traffic rated grate as well as a "sump" in the bottom to allow for drainage of standing water. This structure will be placed on a bed of 57 stone, which will serve as both a foundation for the structure as well as provide drainage underneath the sump. We assume that the top of the grate will be approximately 6" above the rip rap. Option B is to furnish a flexible hose to the Owner for future connection to a "Quick -Connect" coupling, which will be attached to a DIP 45 bend and 8" spool piece which will be oriented towards the ground at 45 degrees to result in the hose connection point at or very close to ground level to decrease chances of kinking in the hose A gravel bed will be provided underneath this connection point to provide for drainage of water during the use of the discharge line and also an 18x18 concrete pad for support. Both options will result in the 8" 90 bend extending out beyond the roof line. Both Options also include provisions for the air release valve PVC piping to penetrate the CMU wall; a credit for the use of a 1/4" sensing line (in lieu of 1/2"), and the electrical costs associated with upgrading the chlorine booster pump. This estimate is based on our best understanding of the changes that are necessary to complete the scope of work. In the event that additional work is required due to unforseen conditions or impacts to other systems, Speegle reserves the right to revisit this estimate. Total estimate for Option A $ 5,150 Total estimate for Option B $ 4,772 Additional Options: 1. - If 8" Ductile Iron Pipe is preferred in lieu of Sch 40 PVC, add $3,610 00 to Option A total 2. - If 8" spool piece and 8" 45 are not necessary, deduct $780.00 from Option B total Should you require any additional information, please do not hesitate to contact Dan Carruth at 850-729-2484 or email dcarruth@speegleconstruction.com cc: file Sincerely, Dan larruth Project Manager