HomeMy Public PortalAbout614.14 WMS Boys 100 CD Bid Set Drawings.Project Summ a r v following description be -Bo sLockerRoomRenovation The summary is a general and is not intended to an all inclusive scope of work: The locker room renovation intends to provide general MEP improvements and upgrades. An additional boy's bathroom added within the locker room will provide two additional toilet stalls and two additional sinks. The former staff bath and janitor closet will be demolished to provide an area for gender neutral changing with a toilet stall and sink. 68 Waverly Ave, Watertown, MA 02472 The demolition of shower stalls in the boy's locker room will allow for more storage space that the staff needs to store gym equipment and also provide an additional area for changing stalls for the students. 12/20/19 Bid Set DRAWING LIST AF Building Aerial ViewIW"� g = ; ' General Project Information �•�.�► T-1 Title Sheet T-2 Symbols, Abbreviations, Mounting Heights - Demolition R 4, '' D100 Demolition Plan {;, s x tectu a Ar hi r I c r• r A100 Boys Locker Room Floor Plan Y 1 A200 Interior Elevations and Plan Details A201 Interior Elevations and Details A202 Gender Neutral Plan and Elevations A600 Partiton and Door Schedules Fire Protection F001 Fire Protection Legend, Notes and Details F100 Fire Protection Floor Plans �i' FA100 Fire Alarm Riser Diagram Plumbing P001 Plumbing Legend, Notes and Schedule PD100 Plumbing Demo Plans P100 Plumbing Floor Plans O P101 Plumbing Floor Plans 1 - y Mechanical % f �` area of Work H001 HVAC Legend and Specifications H002 HVAC Schedules O r _ p o n-0 r. H003 HVAC Details H100 HVAC Floor Plans �■■� i■■� i Electrical E001 Electrical Legend, Notes and Specifications f E002 Electrical Fixture Schedule and Details ED100 Electrical Demolition Plan E100 Electrical Lighting and Power Plans Locus Plan O University 4f Massachusettsn College of ® Planet Fitness c g�E Al c Agriculture fie, st 6eea gL 1,,p , _ a pe46 PO w n �,xbi ,�' m mY a "prr 7 A aun+na�St a s �Y` tham � Pequossette Station a" Hat S` Par k n St Patrick's Cem-etery Cushing Ave 4 WARRENDALE414 9 g V _ "mn ont $t O 4b C Wly. 3 4 z c � : „R n R @ a e ru°r'+ 44v@ 3ht ff a WQ� 'Mayty ''ur1 d'` '�Brn44h Ao-@ U k a= q �' ¢ 4� Cq ffiM9r�c .a❑ Ore � i �Z � � q�0we.74r, A Ridgelawn Cemetery P !t cunnifF A�9 w Lowell Schaal `I Elementary School 61 _N11 w $ �i ejr0' 4 ¢ ore Place 4r "' 0 Victory Field Ffwy 20 �, �� � qy �"�r Watertown � ,� �' � r � P Middle School �; � � Whitney �, " c Hill Park w w " a 4 p�°_r &'°hsrn� OWNER/CLIENT ARCHITECT 4� �� Ji � ��n':"d a t e r t n •J: n m m � e Central Rock Gym GIENAPP f pleases s'v Town of Watertown ARCHITECTS BLW Engineering pf�as Russa's Forte Park , � d�r� s Begin Here. Finish Well. W ' California St E'� �lUPr Arsenal�� Cali Forr, is St Arsenal Gas" ^ 149 Main Street Watertown, MA 02472 311 Great Road 20 Conant Street 978-750-9062 Littleton, MA 01460 Danvers, MA 01923 gienapparchitects.comT=1 m _ T: (978)-486-4301 L— w J � Q J cU �r o z 0 iz O 00 o U T U/ II T U N U) rr In T J U J C/D Q U 0 0 C/) U 0 o rr T Q II U N T co CY) 71- co CV O N z U) T J W U = o U) ~ T O H T I I T RIi CV W J Q U O U) 0 CV T LO w J U O JW 'IF ' - ' L N 0 r� r Site Access Plan C) N i i• IYf ' � r I Jill:11LI I T•3. ' ti i F11111111111111111016. I - OL India, F Dashed line indicates edge of blocking in wall - Typ• o L TP PT Toilet Room Accessories ain Entrance ikoft- Loading Dock yM==lllllllllllllllliiJW6 N. 0 EO r ' •r. - r IL rr ' :• I _ 1 Provide blocking per manufacturer's recommendation O T N AM Provide blocking per manufacturer's recommendation T r\ r\ r\ N SD MR CH SIG UR WG Abbreviation Legend GENERAL ABBREVIATIONS: AFF Above Finish Floor IDYV65 Drawings FR Fire Rated NIC Not in Contract OC On Genter PT Pressure Treated SAFB Sound Attenuation Fire Batt T Tempered TBD To be determined UNO Unless Noted Otherwise VIF Verify in Field TOILET ROOM ACGESSOR I ES CH Goat Hook GR Grab Bar MR Mirror MT Marble Threshold PT Paper Towel Dispenser SD Soap Dispenser SIG Sink TP Toilet Paper Dispenser Refer to the Mounting Height Schedule for additional toilet room accessory information. J- c E N x Cz E N T 0M GB: Grab bar Symbol Legend # ' Section Tag # I # Enlarged Detail Tag # 1 Ref Q) a) 101 4(1 Al1 cc: Elevation Tag 1 Ref Column Grid Tag 1 i — Partition Type Tag r_ I 101 Door Tag Ceiling Type 1 t 1'-0" A.F.F. Ceiling Height Room name Room Name 101 = Room Number Project North Project North Ceiling Finish Wall Finish CW B F Base Finish Floor Finish Room Finish Tag 6" Grade 2 Braille Pictogram d 0 Note: To be installed on the latch side of the door Lettering -Upper case characters -Raised 1/32" G5 Code 5ignage GIENAPP DESIGN ARCH ITECTU RE 20 Conant Street Danvers, MA 01923 978.750.9062 gienappdesign.com Plot Date:12/17/2019 5:15:25 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED, THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: Designer Check by: Checker Date: Scale: As indicated Symbols, Abbreviations, Mou nti ng Heights T-2 N p T N T T w J i Q J U o U) z 0 it O `'' o U T C) II Q r U N UD IZ In W T J U J C/D Q 0 0 W LL] b o rr r Q _II U N T c9 CY) X 71- co CV O N Cn T w I--I--I Q w 0 = CD U U) N - ,— O T r u 0 N T (D T LO w J Q U o C/) Boy's , Toilet 171 SF Remove and di5po5e ceiling tile and grid typ. (02 411q) Remove and di5po5e light fixtures typ. (02 411q) Remove and di5po5e plaster ceiling (02 411q) 'Office' --- ---- -1-2-g -SF D Staff Jan. Bath 39 SF 26 SF B oy's Dressing Room 649 SF Remove and di5po5e cabinE unit heater (25 0000) Shower Room 257 SF Remove and di5po5e light fixtures typ. (02 411q) Boys Locker Room Reflected Ceiling Demolition Plan 1 /8" = 1 '-0" Od T t Legend \ Remove and di5po5e BO 'S��' 5lab for underground r7 y plumbing installation H Dressing (02 411q) H Room U -- Office i M F0 2 Bo ,s Locker Room Floor Slab Demolition Plan 1/8 =1-0 IF_ ,t Provide rough opening for future door and frame (02 411 q) Existing lockers Remove and di5po5e existing changing cubbie5 typ. (02 411 q) Provide rough opening for future 3' door and 2" frame (02 411 q) Remove and di5po5e of existing lockers this location locker5 a5 needed for entrance clear Space) (02 411 q) Remove and d is of rubber tilE Remove and d i5K f ixtu re5 ty 1 �BoLocker Room Demolition Plan =1-0 Demolition Legend Partition to be removed and d i5po5ed Partition to remain Door to be removed I u Door to remain Note: Dashed lines on demolition plans indicates items to be removed and continuous lines indicates items to remain u.n.o. RCP Legend Ceiling Type 111'4' A.F.F. Ceiling Height 1z Direct/indirect lay -in FE-11 fixture - 5ee electrical drawings 0 Downlight - 5ee electrical drawings L'7 � inn �. i � � in ii ii i � ✓� � � � ✓� I i i inn � i in � Return register - 5ee mechanical drawings Supply diffuser - 5ee 121 mechanical drawings Concealed Sprinkler head - See fire protection drawings Sprinkler head - 5ee fire protection drawings Begin Here. Finish Well. 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.corn Plot Date:12/17/2019 5:15:22 PM © 2019 Gienapp Architects, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP ARCHITECTS. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE- TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP ARCHITECTS AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: NB Check by: IB Date: 11 /26/14 Scale: As indicated Demolition Plan Di 00 N r T W J Q J �r o z 0 iz O C0 o U r U II Q r U N C� rr In W T J U J C/D Q 0 0 U) W 0 o � r Q _II U)N T co X 71-M CV O N U) T J W U = o C/) U) Cf) ~ r O Lt- T I I r o�60 T 0 T w J Q U o CO - 3" A.F.F. O SD 0 1 SD Provide LED fixtures typ. (26 0000) Provide ACT, install to match existing ceiling height typ. unless noted otherwise (Og 5123) Existing column to remain Provide steel plate cased opening and lintel at new rough opening (05 5000) with grout (03 3000) Fabricate wood cubbies see detail 4 / A201 (06 1000) Paint all cubbies typ. (Oq 11123) -' 1L F F - BI SD SD Boys Locker Room Reflected Ceiling Plan 1 /4" = 1 '-0" Provide rubber floor tile at Former lockers to match existing (Oct 651(q) Paint wall to match existing at former lockers typ. (Oct g123) Fabricate wood cubbies see detail 4 / A201 (06 1000) Paint all cubbies typ. (Oct g123) Paint existing doors and frames typ. (Oq g123) Provide furring wall typ. (Og g200) see partition schedule for type. Paint walls typ. (Og g123) 1 Bo ,s Locker Room Floor Plan 1/4 = 1 - 0if MT 1T 00, SD SD R 4 4 u 0 LINTEL SCHEDULE 1. Provide metal lintels over all openings except MASONRY OPENING LINTEL SIZE where lintel blocks are provided and except where called for in the drawings. UP TO 3'-0" L 3 1/2" X 3 1/2" X 5/16" 2. Provide one angle for each 4" of wall thickness. For 6" walls, provide tee or built-up section with 3'-1" TO 4'-6" L 4" X 3 1/2" X 5/16" (4" leg vertical) properties equal to or greater than 1 1/2 times the angle properties for a 4" wall thickness. 3. Provide 5" of bearing each end of all lintels. 4. Lintels shall be galvanized. 4'-7" to 6-0" L 5" x 3 1/2" x 5/16" (5" leg vertical) 6-1" to &-0" L 6" x 3 1/2" x 5/16" (6" leg vertical) RGP Legend Ceiling Type 1 t V-0" A.F.F. Ceiling Height Direct/indirect lay -in El Fixture - see electrica drawings 0 Downlight - see electrical drawings 1 ssi 1A 3 3 Office 128 SF 1 102 MIL-00 — ■■■■Gig ���r■■■■■■■■ I■■■E■\I EE■■■■■■■■■E �I■■E■■E► ■■E■■■■■■■■E '■1■ [ 1 ■■■■■■■■ I Ism., 0► .I__ I■■■■■■■■ ■■\■■► ��■■1 I■■■■■■■■ ■■■■■ ■■EI I■■■■■■■■ 1 MINE■\\ EE■1 I■■■■■■■■ 1 ■■■ME E■■1 I■■■■■■■■ ■iNOMINEE ■■■■■■■■■ I■■1 I ■E�'� ■■EMI■■■■■ I■■1 I ■r ■■�■■■■■ I■■1 I MIL ■�■■■■■■■ IST+.I like■■■ 301 III • � • • • 11 5 TP I I I - 0" Imin. 4B Return register - see mechanical drawings ElSupply diffuser - see mechanical drawings Goncealed sprinkler head - see fire protection drawings Sprinkler head - see fire protection drawings Boys I Dress Toilet I 1 141 SF 1 1 I I 1 A200 Provide cabinet unit heater above (23 0000) Paint walls typ. (Oq g123) Provide coat hooks at all stall locations typ. (10 2500) Provide rubber floor tile (Oq 651g) 1 and wall base (Oq 6513) throughout locker room Provide concrete infill, (03 3000) skim coat at former shower floors and former drip area (Oq 3000) Provide accesible folding bench For changing (10 2116) 15' - 6 1/2 1A i7_lz ' Provide lockable access panel for existing electrical box (05 5113) Provide connections for Future washer dryer see plumbing and elec. drawings RGP Legend Exit Sign Pull Station PS SD Smoke Detector Emergency Lights O O 14, - 1 3/4" 4B 13 S 4B 4B e a i Gi G v i i i i � v iv Begin Here. Finish Well. 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.com Plot Date:12/17/2019 5:15:09 PM © 2019 Gienapp Architects, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP ARCHITECTS. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE- TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP ARCHITECTS AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: NB Check by: IB Date: 8/22/18 Scale: As indicated Boys Locker Room Floor Plan Al 00 LLJ J Q o � N p r N JII T w J i Q J cU c� z 0 iz O r' o U r U II U N U) rr In W T J U J C/D Q 0 0 � W 0 b o rr r Q _II U N T co c) X 71- co CV O N z Cn T J W U = o U) Cn ~ r o Lt- T I I r :. o160 T 0 T LO w J U o CO NOTE: Ceramic tile pattern typical f, recieving ceramic tile u.n.o. ty p. M Door (05 1113) in existing frame (verify dimensions in field) 1.=..II---- 1-;I— vvvc r�a�c CeramicWall Tile Pattern 3/411=1 1-011 Interior Bathroom Wall Elevation - West 1 /2" = 1 '-0" / / / / / / 102 \ Office Wall Elevation 1 /2" = 1 '-0" Provide lay -in light fixture typ. (26 0000) = Color 1 = Color 2 Provide sink (22 0000, Provide janitor mop basin (2� 0000, Provide wood cubbieE see detail 4/A201 (06 1600, Paint cubbies typ. (Oq g123, Existing windows to remain Skim coat and ceramic wall the to 6" above hung ceiling (Oq 5000) Provide door and frame (051113) see door schedule. Provide acoustic ceiling tile (Oq 5123) Provide ceramic wall tile above /Standard tile pattern height (color #1) (Oq 3000) Toilet partition II II ------- -- ---------- -- � \ \ II � � II II � II v v II II II II v II II II SK / / / II II / II / / / II II / / II II / II Interior Bathroom Wall Elevation - North 1 /2" = 1 '-0" r t vviuc c.ci antic. i ivvt �ii� Detail Plan typ (0q coat(03 3000) �_Bathroom 1 /211 = 1 1-011 ///— Geramic wall tile base (Oq 3000) \ i B y's Ceramic tile typ. (Oq uress\ 3000) Toilet 103 / / / WG ' / / Interior Bathroom Wall Elevation - South 1 /2" = 1 '-0" (10 211r) (beyond) Provide ceramic wall tile typ. (Oq 3000) see pattern 'i / A200 Provide acoustic ceiling tile (Oq 5123) Provide toilet partition (10 211(c) GB TP 1NG _� TP 1NG Interior Bathroom Wall Elevation - East 1 /2" = 1 '-0" E e 0 E E a i Gi G v i i i i � v iv Begin Here. Finish Well. 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.corn N O � N O � Q L L O U •— O > c� C: CL) W Q >1 c>� 00 Plot Date:12/17/2019 5:15:12 PM © 2019 Gienapp Architects, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP ARCHITECTS. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE- TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP ARCHITECTS AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: NB Check by: IB Date: 09/21 /18 Scale: As indicated Interior Elevations and Plan Details A200 LLJ� J U o N p T N JII T w J i Q J cU o z 0 iz O r' o U T U II U N Cn I rr In W T J U J c/D Q 0 0 C/) W o o r r Q _II U� N T co co X 71- co CV O N U T I W Q W U = o U) U Cf) T o Lt_ T I I T :1 0 T L J W J Q U o C/) II—i—.-,I--,-1-i♦•i.-.— - - — — — — 4­.— /I/'1 1I I/ 1 8 Interior Bo „s Bathroom Wall Elevation North 1/2 =1-0 Interior Boys Bathroom Wall Elevation - South 1 /2" = 1 ' - 0" Provide toilet partition (10 2116) Interior Boys Bathroom Wall Elevation - East 1 /2" = 1 ' - 0" GWB (Og 2g00) and Paint (Og g123) typ. Geramic wall tile typ. (Og 3000) Plumbing fixture typ. see plumbing d raw i ngs (22 0000) 5 Interior Boy„s Bathroom Wall Elevation - West 1/2 = 1 - 0 Plan GWB (Oci 2(q00) and Paint (Og g123) typ. Geramic tile typ. (Og 3000) GWB (Og 2(q00) and Paint (Og (:1123) typ. Provide ceramic wall tile typ. (Og 5000) see pattern 1 1 - 71 3/4" 1' - 5 1/2" 3/4" 4 Changing Cubby Details 1 =1-0 Wood b typ. (OE 3-D Solid plastic changir partitions typ. (10 211(b) Provide coat hookE- two interior partitic (10 2500) Solid plastic bench (10 211r ) Typical Changing Stall 3D 5/4" plywood typ (O6 1000) Vinyl cove base (Og 6513) 31 - 011 F71\_ CH CH 41, I 2' - / 11 �J 411 � Typical Changing Stall Plan 3/411 = 1 '-0" Solid plastic partition door and hardware typ. (10 211(c) Provide solid plastic bench typ. (10 2116) Provide coat hooks typ. (10 2500) Provide solid plastic door typ. (10 2116) E e 0 E E a i Gi G v i i i i � v iv Begin Here. Finish Well. 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.com N O � N O � rAO000 Q O U •— O >� c>� C: W Q V J 00 Plot Date:12/17/2019 5:15:15 PM © 2019 Gienapp Architects, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP ARCHITECTS. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE- TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP ARCHITECTS AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: NB Check by: IB Date: 11 /14/18 Scale: As indicated Interior Elevations and Details A201 LLJ J Q o � N p T N JII T w J i Q J cU �r o z 0 iz O r' o U T U II U N Cn rr In W T J U J C/D Q 0 0 C/) U 0 o r r Q _II U� N T co co 71- co CV O N z UD T J W U = o U) UD Cf) T O Lt_ T I I T :. 0 T LO w J Q U o C/) GWB (Oq 2g00) and Paint (Og g123) typ. Provide ceramic wall tile typ. (Og 3000) GWB (Oq 2g00) and Paint (Og g123) typ. Provide ceramic wall tile typ. (Oq 3000) \ \ Ger ider NeL tral 101 \ i 112 SF / i Gender Neutral West Elevation 1 /2" = 1 '-0" Provide door a (05 1113) See d sc.hedule Gender Neutral 1112 SF MR 5K Gender Neutral North Elevation 1 /2" = 1'-0" Floor Plan- Gender Neutral Bathroom 1 /2" = 1 '-0" Provide ceramic wall tile typ. (Oq 3000) Gender Neutral South Elevation 1 /2" = 1 '-0" aint (Oq g123) typ. Provide toilet partition (10 2116) / / / / / Gender Neutral /v Dressing \ 112 SF Gender Neutral East Elevation 1 /2" = 1'-0" /-- GWB (O(:1 2g00) and Paint (Oq g123) typ. i Provide toilet partition (10 2800) m e 0 m m a i Gi G v i i i i � v iv Begin Here. Finish Well. 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.com N O � N O � rAO000 Q O U •— O > c� C: O ., \ > W C)e Q i >1 L c>� 00 Plot Date:12/17/2019 5:15:17 PM © 2019 Gienapp Architects, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP ARCHITECTS. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE- TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP ARCHITECTS AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: NB Check by: IB Date: 12/02/19 Scale: 1/2" = 1'-0" Gender Neutral Plan and Elevations A202 w J Q o � N p T N JII T h- w J i Q J cU �r o z 0 iz O 00—o U T U/ II T U N U) rr In W T J U J C/D Q 0 � 0 w 0 �0 o rr T Q II U N T co cY) X 71- co CV O N v) T J J 0 = CD ~ T O Lt_ T I I T u CV w J Q O U) 0 T I I 0 00 CV \ T O T LO Door Schedule No. Door Type Door Size Door Frame Detail5 Hardware Set Notes Height Width Mat. Finish Mat. Fini5h Head Jamb Thre5h 100A A< 7 - 0" 3' - 0" MTL PNT HM PNT 0a55room deadbolt w/ pu5h/pull Provide ma5onry lintel 100E3 A< 7 - 0" 3' - 0" MTL PNT HM PNT Pu5h/pull 101 A< T - O" 3' - O" MTL PNT HM PNT Gla55room deadbolt w/ pu5h/pull 102 A 7 - O" 2'- 5" MTL PNT EXT6 PNT Office Verify exi5ting dimen5ion5 in field 103 A< 7 - O" 3' - O" MTL PNT HM PNT Pa55ag_e Storeroom 104 A< 7- 0" 3' - 0" MTL PNT HM PNT 105 A< 7- O" 3' - O" MTL PNT HM PNT Storeroom 106 A< 7- O" 2'- 10" MTL PNT HM PNT Gla55room deadbolt w/ push/pull Verify existing dimensions in field DOOR TYPES (05 141(o) 0 Varies See schedule Flush metal A<� Door Legend 1 /2" = 1 '-0" N DOOR FRAME TYPES (08 1113� 2" See schedule 2" Hollow metal frame 1 Partition Schedule 11 Penetration Description Description Description Description Fire Stopping 3-5/5" metal Stud @ 1h" o.c. • 3-5/5" metal Stud @ 1h" o.c. Geramic Tile on Exi5ting 1" Metal hat channel both Sides 5/5" ABUSE RESISTANT 6WB • 5/5" ABUSE RESISTANT 6WB 6WB Substrate • 61a55 fiber Batt in5ulation one Side only �t Structure Structure 0 SAFB a, Slip Track J Height: 4" above �4TGGT • Height: To 4" above • Height: to under5ideGT of Structure 1A Height: To under5ide 3 4 5/5" Gement Board S�4FB Head of Structure 2 Head Head 0 Head 6WB Geramic Tile c� E Metal laythe • 5/8" cement board Exi5ting Height: To 4" above .�� and ceramic tile fini5h GMU Wall Scratch coat 1" Mtl. channel ACT one Side Plan 5/5" cement board4A 2 Geramic tile fini5h = Mortar bed Exi5ting GMU wall) Dement board 5/5" 6WB Plan Plan Bond coat Plan Ceramic the Geramic tile Base Base Base Ba5e Bullno5e tile Bullno5e tile RGB typ Plumbing Ghaee Bathroom Partition Bathroom Partition Standard Non- Partition (4A Shown) Bearing Partition General Partition Notes: • Where partition appears to extend an exi5ting partition, align the face of 6WB with the exi5ting 6WB for a Smooth 5urface unle55 noted otherwi5e. • All new partition5 are to have acou5tical 5ealant. • For better Sound isolation, do the following: • Stagger electrical boxes in the partition to avoid being back to back. Where po55ible, place electrical boxes in different Stud cavities. • At all penetrations in office area (Structure 1), regardless of fire rating, provide fire Stopping for Sound insulation per 0-7 5415. Provide fire 5topping at all penetrations in rated a55emblie5 (0-7 5413). i Gi G v i i i i � v iv Begin Here. Finish Well. 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com N O � N O � IrA0000 Q i O U •— O CL) > c� C: O C \Cl.) W C)e Q >1 V J 00 Plot Date:12/17/2019 5:15:19 PM © 2019 Gienapp Architects, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP ARCHITECTS. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE- TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP ARCHITECTS AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. No. Date Description Project: 614.14 Drawn by: NB Check by: IB Date: 09/21 /18 Scale: As indicated Partiton and Door Schedules A600 r 0 _I� J M N T N r n t i oJU) 0 z_ 0 0 o U -� W Q N U U) z I r W Q w U Q U) U p o C/) U � co 0 rr r Q J //N `+) r C9 C") CV 0 N z U) T J W Q W U = o Cf) U) r o LL_ r r E 0 N w J Q U o ME I 0 T LO w J Q U o Cf) NOTES EIRE PROTECTION ABBREVIATIONS AFF ABOVE FINISH FLOOR 1. ALL FIRE PROTECTION SYSTEMS, EQUIPMENT AND PIPING SHALL BE DESIGNED, INSTALLED AND TESTED ® WET SYSTEM ALARM CHECK VALVE AND RISER AP ACCESS PANEL BY A SPRINKLER CONTRACTOR LICENSED AND EXPERIENCED IN THE STATE OF MASSACHUSETTS IN THE DESIGN, INSTALLATION AND TESTING OF STANDARD AND RESIDENTIAL SPRINKLER SYSTEMS. CLG CEILING 2. ALL WORK PERFORMED SHALL CONFORM TO THE APPLICABLE SECTIONS OF F UNDERGROUND FIRE PROTECTION MAIN - BUILDING SERVICE DWG DRAWING THE MASSACHUSETTS STATE BUILDING CODE AND NFPA 13 LATEST ACCEPTED EDITION AS WELL AS ALL RULES AND REGULATIONS OF THE AUTHORITY HAVING JURISDICTION. 3. ALL PIPING IN EXPOSED AREAS SHALL BE OF A TYPE SUITABLE FOR PAINTING NEW WET PIPE SYSTEM SPRINKLER PIPING EL ELEVATION ALL PIPING SHALL BE RUN CONCEALED WHEREVER POSSIBLE FIFE FINISH FLOOR ELEVATION 4. CONTRACTOR SHALL PROVIDE FIRESTOPPING FOR ALL PENETRATIONS THRU FIRE WALLS EXISTING WET PIPE SYSTEM SPRINKLER PIPING F FIRE SERVICE MAIN AND FIRE RATED SEPARATIONS. 5. ALL SPRINKLER PIPING AND HEADS ARE SHOWN DIAGRAM MATICALY. CONTRACTOR SHALL DCBP DCBP DOUBLE CHECK VALVE BACKFLOW PREVENTER FLR FLOOR COORDINATE WITH ALL OTHER TRADES BEFORE WORK BEGINS TO INSURE THAT NO INTERFERENCE'S INV INVERT EXIST AND THAT ALL COMPONENTS OF THE SPRINKLER SYSTEM WILL FIT INTO THE SPACE. 6. CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL AND ELECTRICAL DRAWINGS FOR HI FDC FIRE DEPARTMENT CONNECTION. TYPE AND LOCATION AS DIRECTED BY THE LOCAL FIRE DEPARTMENT NITS NOT TO SCALE LOCATIONS OF DUCTWORK, DIFFUSERS AND LIGHT FIXTURES. CONTRACTOR SHALL NIC NOT IN CONTRACT COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR CEILINGS, CEILING SPACES AND ROOMS. � EXISTING SPRINKLER HEAD TO REMAIN - PENDENT -ORDINARY TEMPERATURE -STANDARD RESPONSE TYPE TS TAMPER SWITCH 7. CONTRACTOR SHALL FURNISH, INSTALL AND MAINTAIN ALL SCAFFOLDING, HOISTING EQUIPMENT AND DERRICKS NECESSARY FOR INSTALLATION OF WORK TYP TYPICAL 8. THE DRAWINGS SHALL NOT BE USED BY THE CONTRACTOR AS SPRINKLER SYSTEM SHOP DRAWINGS. THE CONTRACTOR SHALL PRODUCE A COMPLETE OO NEW SPRINKLER HEAD - PENDENT - ORDINARY TEMPERATURE - STANDARD RESPONSE TYPE W/ WITH SET OF WORKING FIRE PROTECTION SYSTEM SHOP DRAWINGS IN ACCORDANCE WITH NFPA 13. THE SYSTEM SP SPRINKLER PIPING SHALL BE HYDRAULICALLY CALCULATED PER THE DESIGN CRITERIA PROVIDED AND REQUIRED. ALL DRAWINGS DN DOWN AND CALCULATIONS SHALL BE STAMPED AND SIGNED BY THE CONTRACTORS REGISTERED FIRE PROTECTION 0 EXISTING SPRINKLER HEAD TO REMAIN - UPRIGHT - ORDINARY TEMPERATURE - STANDARD RESPONSE TYPE ENGINEER AND SHALL BE SUBMITTED TO THE LOCAL FIRE DEPARTMENT FOR APPROVAL AND PERMIT. THIS SHALL BE O.S. & Y. OUTSIDE SCREW AND YOKE VALVE DONE PRIOR TO THE COMMENCEMENT OF ANY SPRINKLER WORK. AN ADDITIONAL SET OF PLANS AND CALCULATIONS AS DESCRIBED ABOVE SHALL BE SUBMITTED TO THE LOCAL BUILDING DEPARTMENT O° NEW SPRINKLER HEAD - UPRIGHT - ORDINARY TEMPERATURE - STANDARD RESPONSE TYPE FDC FIRE DEPARTMENT CONNECTION FOR APPROVAL PRIOR TO THE COMMENCEMENT OF ANY SPRINKLER WORK. PLANS AND HYDRAULIC CALCULATIONS AS DESCRIBED ABOVE SHALL ALSO BE SUBMITTED TO THE OWNERS INSURANCE AUTHORITY AND THE ARCHITECT FOR APPROVAL PRIOR TO THE COMMENCEMENT OF ANY SPRINKLER WORK. EXISTING SPRINKLER HEAD TO BE REMOVED ALL DRAWING SUBMITTALS SHALL INCLUDE COMPLETE SYSTEM RISER DIAGRAMS. CHECK VALVE ALL SUBMITTALS SHALL INCLUDE MANUFACTURERS ORIGINAL CATALOG DATA AND DESCRIPTIVE INFORMATION FOR ALL MAJOR COMPONENTS OF THE EQUIPMENT TO BE SUPPLIED. ALL DRAWING SUBMITTALS SHALL INDICATE ALL CONTROL VALVES, SUPERVISORY AND ALARM SWITCHES, ALL TEST AND DRAIN VALVES. ELBOW UP OR RISE NO FIRE PROTECTION SYSTEMS PIPE FABRICATION OR ANY INSTALLATION WORK AT THE SITE SHALL BEGIN UNTIL THE SPRINKLER CONTRACTOR HAS SUBMITTED THE SPRINKLER ELBOW DOWN OR DROP CONTRACTORS ENGINEERED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS AND ALL SUPPORTING MATERIAL, ALL AS DESCRIBED ABOVE, TO THE LOCAL FIRE DEPARTMENT AUTHORITY FOR PERMIT, THE BUILDING DEPARTMENT AND THE OWNERS INSURANCE AUTHORITY FOR APPROVAL. THE SPRINKLER CONTRACTOR SHALL OBTAIN THE PERMIT AND INSPECTORS COMBINATION TEST AND DRAIN ASSEMBLY WRITTEN APPROVALS FROM THE ABOVE LISTED AUTHORITIES PRIOR TO THE COMMENCEMENT OF ANY WORK ASSOCIATED WITH THE FIRE PROTECTION SYSTEMS. 9. PROVIDE WIRE CAGE GUARD PROTECTION FOR ALL SPRINKLER HEADS INSTALLED IN MECHANICAL ROOMS AND UTILITY CLOSETS UNLESS CONCEALED TYPE HEADS ARE USED 10. THE DRAWINGS ARE NOT INTENDED TO SHOW EXACT SPRINKLER HEADS LOCATIONS, NUMBER OF SPRINKLER HEADS, OR THE EXACT ROUTING OF PIPING. THIS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR ALL CEILING TYPES 11. SPRINKLER CONTRACTOR SHALL PROVIDE ALL CUTTING AND PATCHING IN ORDER TO ACCOMMODATE THE SPRINKLER WORK. 12. THE CONTRACTOR SHALL MAKE REASONABLE CHANGES TO THE SPRINKLER HEAD LOCATIONS AS A RESULT OF THE COORDINATION WITH THE MECHANICAL AND ELECTRICAL DRAWINGS AND AT NO EXTRA COST TO THE CONTRACT. 13. THE TERM "CONTRACTOR" SHALL MEAN "SPRINKLER CONTRACTOR" 14. THE CONTRACTOR SHALL PROVIDE A FIRE DEPARTMENT PERSONNEL STAFFED "FIRE WATCH" DURING ALL WELDING OPERATIONS. 15. THE SPRINKLER CONTRACTOR SHALL PROVIDE A MINIMUM OF 48 HOURS ADVANCE NOTICE TO THE LOCAL FIRE DEPARTMENT PRIOR TO THE FINAL SPRINKLER SYSTEMS ACCEPTANCE TEST. THE FINAL ACCEPTANCE TEST SHALL BE WITNESSED BY THE LOCAL FIRE DEPARTMENT. ANY DEFECTS FOUND DURING THE ACCEPTANCE TEST SHALL BE REPAIRED BY THE SPRINKLER CONTRACTOR AND THE ENTIRE SPRINKLER SYSTEM RETESTED AS DESCRIBED ABOVE. THIS SHALL BE REPEATED UNTIL THE SPRINKLER SYSTEM IS FREE OF ALL DEFECTS AND THE ENTIRE SPRINKLER SYSTEM IS ACCEPTED BY THE LOCAL FIRE DEPARTMENT. 16. THE SPRINKLER CONTRACTOR SHALL PROVIDE THE LOCAL FIRE DEPARTMENT WITH A COPY OF THE SPRINKLER SYSTEMS TEST RESULTS 17. THE SPRINKLER CONTRACTOR SHALL COORDINATE WITH THE LOCAL FIRE DEPARTMENT FOR ALL REQUIREMENTS FOR APPROVAL AND ACCEPTANCE OF THE SPRINKLER SYSTEMS AND DESIGN DRAWINGS, PRIOR TO THE COMMENCEMENT OF ANY SPRINKLER DESIGN OR INSTALLATION WORK 18. THE SPRINKLER CONTRACTOR SHALL CAREFULLY COORDINATE THE INSTALLATION OF ALL PIPING, VALVES AND EQUIPMENT IN THE SPRINKLER ROOM WITH THE PLUMBING CONTRACTOR TO INSURE THAT BOTH TRADES FIT INTO THE SPACE WITHOUT INTERFERENCE. 19. THE SPRINKLER CONTRACTOR SHALL PROVIDE ALL SPRINKLER HEADS WITH FACTORY APPLIED COLOR FINISHES TO MATCH THAT OF THE FINISH OF THE CEILING OR WALL THAT THE SPRINKLER HEAD IS BEING INSTALLED INTO. THE SPRINKLER CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT FOR ALL CEILING TYPES AND FINISHES PRIOR TO PURCHASE AND INSTALLATION OF THE SPRINKLER HEADS. 20. THE SPRINKLER CONTRACTOR SHALL PROVIDE ALL SPRINKLER HEAD SUPPLY DROPS OR SPRIG UP RISERS TO AND INCLUDING FINAL CONNECTION OF ALL SPRINKLER HEADS 21. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING ALL AREAS OF HYDRAULIC CALCULATIONS BASED ON NFPA-13 AS APPLICABLE 22. REMOTE DESIGN AREAS ARE NOT SHOWN ON THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR TO SELECT ALL DESIGN AREAS AND DESIGN DENSITIES AS WELL AS THE NUMBER OF SPRINKLER HEADS IN ALL AREAS OF OPERATION THAT WILL BE USED TO CREATE THE SPRINKLER CONTRACTORS SHOP DRAWINGS AND HYDRAULIC CALCULATIONS. ALL DESIGN AREAS, DESIGN DENSITIES AND THE NUMBER OF OPERATING SPRINKLER HEADS SHALL BE SELECTED BY THE SPRINKLER CONTRACTOR IN ACCORDANCE WITH NFPA-13. HYDRAULIC CALCULATIONS SHALL BE PERFORMED FOR EVERY BUILDING REQUIRING SPRINKLER COVERAGE. 23. THE DRAWINGS ARE NOT INTENDED TO SHOW ALL FIRE RATED SEALS THRU RATED FLOORS AND WALLS. THE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE ARCHITECTURAL DRAWINGS FOR ALL FIRE RATED FLOORS AND WALL AND SHALL PROVIDE A FIRE RATED SEAL FOR EACH AND EVERY PIPE PENETRATION THRU EACH AND EVERY FIRE RATED FLOOR OR WALL. 24. PRIOR TO THE SPRINKLER SYSTEMS DESIGN, THE SPRINKLER CONTRACTOR SHALL CONDUCT A HYDRANT FLOW TEST IN ORDER TO OBTAIN CURRENT FLOW AND PRESSURE DATA AND SHALL USE THIS NEWLY OBTAINED DATA TO PERFORM HIS HYDRAULIC CALCULATIONS FOR THE SPRINKLER SYSTEM SHOP DRAWINGS DESCRIBED IN NOTE 9 ABOVE. THE HYDRANT FLOW TEST SHALL BE CONDUCTED IN ACCORDANCE WITH NFPA-13. THE CONTRACTOR SHALL COORDINATE WITH THE LOCAL WATER AUTHORITY FOR THE FLOW TEST. THE SPRINKLER CONTRACTOR SHALL PROVIDE ALL LABOR, EQUIPMENT, MATERIALS, PAY ALL FEES AND PERFORM ALL COORDINATION WITH THE LOCAL WATER AUTHORITY FOR THE HYDRANT FLOW TEST. 25. THE FIRE PROTECTION CONTRACTOR SHALL CREATE A SCALE DRAWING FOR THE BUILDING SHOWING THE LOCATIONS OF ALL BACKFLOW PREVENTION DEVICES AND DETAILS OF EACH OF THEIR INSTALLATION METHODS. THE FIRE PROTECTION CONTRACTOR SHALL ALSO OBTAIN MANUFACTURER CUT SHEETS OF ALL BACKFLOW PREVENTION DEVICES AND SHALL INDICATE THE SIZES AND MODEL NUMBERS BEING USED. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT THESE DRAWINGS AND CUT SHEETS TO THE LOCAL WATER DEPARTMENT AUTHORITY FOR APPROVAL. NO BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED UNTIL WRITTEN APPROVAL OF ALL BACKFLOW PREVENTION DEVICES HAS BEEN OBTAINED BY THE FIRE PROTECTION CONTRACTOR FROM THE LOCAL WATER DEPARTMENT AUTHORITY. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR REGISTERING ALL BACKFLOW PREVENTION DEVICES WITH THE LOCAL WATER DEPARTMENT AS WELL AS THE MASSACHUSETTS D.E.P. 26. THE FIRE PROTECTION DRAWINGS ARE NOT INTENDED TO SHOW ANY CEILING CONDITIONS, LIGHT FIXTURES, HVAC DIFFUSERS OR ANY EQUIPMENT OR DEVICES LOCATED IN THE CEILINGS. THE SPRINKLER CONTRACTOR SHALL OBTAIN ARCHITECTURAL CEILING PLANS, ELECTRICAL PLANS AND HVAC PLANS AND SHALL COORDINATE THE SPRINKLER HEAD LOCATIONS WITH ALL CEILING TYPES, LIGHT FIXTURES, HVAC DIFFUSERS AND ALL DEVICES AND EQUIPMENT THAT WILL BE LOCATED IN THE CEILINGS. THE SPRINKLER CONTRACTOR SHALL ADJUST THE LOCATIONS OF THE SPRINKLER HEADS SHOWN ON THE FIRE PROTECTION DRAWINGS AS REQUIRED TO COORDINATE WITH THE CEILING CONDITIONS. THESE ADJUSTMENTS SHALL BE MADE AT NO EXTRA COST TO THE CONTRACT. 27. ALL SPRINKLER HEADS SHALL BE LOCATED IN THE CENTER OF CEILING TILES UNLESS OTHERWISE DIRECTED BY THE ARCHITECT. 28. THE FIRE PROTECTION DRAWINGS ARE NOT INTENDED TO SHOW ANY CEILING CONDITIONS, CEILING GRIDS, CEILING TILES, LIGHT FIXTURES, HVAC DIFFUSERS OR ANY OTHER CEILING DETAILS. THE SPRINKLER CONTRACTOR SHALL OBTAIN THE CEILING PLANS, THE LIGHT FIXTURE LOCATIONS AND HVAC DIFFUSER LOCATIONS FROM THE ARCHITECT. THE SPRINKLER CONTRACTOR SHALL USED THIS INFORMATION TO LAYOUT THE LOCATIONS OF ALL SPRINKLER HEADS AND SHALL MAKE WHATEVER ADJUSTMENTS TO THE FIRE PROTECTION DRAWINGS NECESSARY TO ACCOMMODATE THE THE ACTUAL CEILING CONDITIONS. THESE ADJUSTMENTS SHALL BE MADE AT NO EXTRA COST TO THE CONTRACT. 29. EXISTING CONDITIONS: SOME SPRINKLER AND STANDPIPE SYSTEMS WILL BE INSTALLED INTO EXISTING BUILDING CONDITIONS. THE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE AND FAMILIARIZING THEMSELVES WITH ALL EXISTING BUILDING CONDITIONS TO WHICH THE NEW SPRINKLER AND STANDPIPE SYSTEMS ARE TO BE INSTALLED. THE SPRINKLER CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE INSTALLATION OF ALL NEW SPRINKLER AND STANDPIPE SYSTEMS WITH ALL EXISTING BUILDING CONDITIONS. THE SPRINKLER CONTRACTOR SHALL MAKE WHATEVER CHANGES TO THE DRAWINGS NECESSARY IN CONJUNCTION WITH THE COORDINATION WITH THE EXISTING BUILDING CONDITIONS AND AT NO EXTRA COST TO THE CONTRACT. ELECTRIC ALARM BELL PENDENT SPRINKLER HEAD RELOCATION DIAGRAM NOT TO SCALE 4" WET SYSTEM ALARM CHECK VALVE AND TRIM 4" OS&Y VALVE WITH TAMPER SWITCH 4" DOUBLE CHECK BACKFLOW PREVENTER /_ TO SPRINKLER SYSTEM ONNECTION DEPT. CHECK VALVE :RVICE EXISTING SPRINKLER SYSTEM SERVICE NOT TO SCALE FLOW DATA HYDRAULIC CALCULATIONS FOR THIS DESIGN HAS BEEN BASED ON THE FOLLOWING MINIMUM FLOW CRITERIA : STATIC PRESSURE 79 PSI RESIDUAL PRESSURE 70 PSI THE FLOW TEST DATA LISTED SHALL NOT BE USED BY THE SPRINKLER CONTRACTOR AND THE SPRINKLER CONTRACTOR SHALL PERFORM A NEW HYDRANT FLOW TEST TO OBTAIN CURRENT FLOW AND PRESSURE DATA. THE SPRINKLER CONTRACTOR SHALL USE HIS NEWLY OBTAINED FLOW AND PRESSURE DATA TO PERFORM HIS HYDRAULIC CALCULATIONS FOR THE SPRINKLER SYSTEMS DESIGN. THE HYDRANT FLOW TEST SHALL BE PERFORMED IN ACCORDANCE WITH NFPA-13. THE SPRINKLER CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, PAY ALL FEES AND PERFORM ALL COORDINATION WITH THE LOCAL WATER AUTHORITIES IN ORDER TO PERFORM THE HYDRANT FLOW TEST. GENERAL DESIGN CRITERIA LOCKER ROOMS LIGHT HAZARD OCCUPANCY .10 GPM OVER THE MOST REMOTE ROOM PLUS COMMUNICATING SPACE. 100 GPM HOSE STREAM ALLOWANCE NEW SPRINKLERS SHALL MATCH EXISTING HEADS BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection �IENAPI RICHITECT gin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com () N � � N E 0 Q U U 0 0 0 Cf) � > � O � 0 0 ' °U O +, C Q E 0 U O 0 0 � O 00 LD Plot Date: 8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: Check by: Date: 12/18/2019 Scale: As indicated FIRE PROTECTION LEGEND, NOTES AND DETAILS Fool EXISTING UPRIGHT SPRINKLER TO REMAIN (TYP.) w J U 0 N T N J o 0 z 0 O C w J Q N U U) I z In r W J U U) ❑ o U Q U) /�ry/'�'� `C}i ��yy-� V i5o CV O N z T W W = o U) N r 00 T w J Q U) N w J U o 0 N 00 \ T Boi VS M Toilet i 171 �F Bath Jan. 26 SF 4 FIRE PROTECTION - Demo Plan SCALE: 1 /4"= V-0" EXISTING 4" WET SYSTEM ALARM VALVE AND RISER EXISTING 4" DOUBLE CHECK BACKFLOW PREVENTER f-E Li EXISTING 4" FIRE SERVICE I I I I I I I I I I I I I I I I �I I I I I I I I I 23r r-- I I I �I I I I I I I I I I V I I I I IL 4 FIRE PROTECTION - New Work Plan SCALE: 1/4"= V-0" r.--[ DCBP ]� 1` 13L.7ww) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f.978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection �IENAPI RCHITECT gin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com () N EO Q U U O O O Cf) > O O O - °' O� v 0 V / Q E O U O > 0 O � O W LD Plot Date: 8/21/20191:22:19 PM 3 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: Check by: Date: 12/18/2019 Scale: As indicated FIRE PROTECTION PLAN F100 T O II co CV O N T T T II t UD T C9 CYO CV 0 N z (/) T LLj Q W C) O U) Cf) U) r O LL T T K91 0 CV W J U O U) i O T Ln W J U O C0 PLUMBING GENERAL LEGEND ------------- HW 120°F HOT WATER ABOVE FLOOR ----------- CW COLD WATER ABOVE FLOOR ECO ❑0 FD FD FCO FCO D ------EXV------- ---- EXHW ---- --- EXCW --- - -----EXS-------- -----TP ----- SAN V V EXV EXHW EXCW EXS TP HB END CLEANOUT FLOOR DRAIN AS INDICATED FLUSH CLEANOUT SANITARY PIPING UNDERGROUND OR BELOW THE FLOOR SANITARY ABOVE FLOOR VENT ABOVE FLOOR VENT UNDERGROUND OR BELOW FLOOR WATER SERVICE BALL VALVE CAPPED PIPE ELBOW UP OR RISE ELBOW DOWN OR DROP EXISTING VENT ABOVE FLOOR EXISTING 120°F HOT WATER ABOVE FLOOR EXISTING COLD WATER ABOVE FLOOR EXISTING SANITARY PIPING UNDERGROUND OR BELOW THE FLOOR DEMOLITION AREA TRAP PRIMER WATER BELOW FLOOR 1/2" HOSE BIBB WHOSE END VACUUM BREAKER BY WOODFORD BUILDING PLUMBING FIXTURE SCHEDULE TAG No. FIXTURE COLD HOT SAN VENT REMARKS WATER(in) WATER(in) (in.) (in.) TOTO FLOOR MOUNTED, FLUSHOMETER 1.28 GPF, MODEL #CT705ELN, P-1 WATER CLOSET T. - 4" 2" TOILET SEAT MODEL #SC134. TOTO HIGH -EFFICIENCY TOILET ECOPOWER FLUSHOMETER VALVE, 1.28 GPF, MODEL #TET6LN. TOTO FLOOR MOUNTED, ADA ACCESSIBLE, FLUSHOMETER 1.28 GPF, MODEL P-1A WATER CLOSET T. - 4" 2" #CT705ELN, TOILET SEAT MODEL #SC134. TOTO HIGH -EFFICIENCY TOILET HANDICAP ACCESSIBLE ECOPOWER FLUSHOMETER VALVE, 1.28 GPF, ADA ACCESSIBLE, MODEL #TET6LN. TOTO COUNTER MOUNTED, MODEL #LT402. TOTO GOOSENECK P-2 LAVATORY 1/2" 1/2" 2" 2" ECOPOWER FAUCET SINGLE SUPPLY, WITH MIXING VALVE, MODEL LAVATORY #TEL155-D10EM. TOTO COUNTER MOUNTED, ADA COMPLIANT MODEL #LT402. TOTO GOOSENECK P-3 HANDICAP ACCESSIBLE 1/2" 1/2" 2" 2" ECOPOWER FAUCET SINGLE SUPPLY, ADA COMPLIANT WITH MIXING VALVE, MODEL #TEL155-D10EM. TOTO WALL MOUNTED, HIGH -EFFICIENCY, MODEL #UT445U. P-4 URINAL 3/4" - 2" 2" TOTO HIGH -EFFICIENCY URINAL ECOPOWER FLUSHOMETER VALVE, 0.5 GPF, URINAL MODEL #TETUILN. TOTO WALL MOUNTED, HIGH -EFFICIENCY, ADA COMPLIANT, MODEL #UT445U. P-5 3/4" - 2" 2" TOTO HIGH -EFFICIENCY URINAL ECOPOWER FLUSHOMETER VALVE, 0.5 GPF, HANDICAP ACCESSIBLE ADA COMPLIANT, MODEL #TETUILN. ZURN MOP SERVICE BASIN 24X24X10 MODEL #Z1996-24 ZURN MOP SERVICE SINK FAUCET MODEL #Z1996-SF. PROVIDE HOSE & P-6 JANITORS SINK 1/2" 1/2" 2" 211 HOSE BRACKET, VACUUM BREAKER, INTEGRAL STOPS, ADJUSTABLE WALL WASH MACHINE BOX BRACE, PAIL HOOK, HOSE THREAD ON SPOUT. 2" SIOUX CHIEF OX-BOX WITH LAUNDRY DRAIN COMPARTMENT WITH 2" DRAIN AND WATER SUPPLY 1/2" 1/2" 2" P-7 COMPARTMENT WITH INTEGRAL MINI -RESTER WATER HAMMER ARRESTERS. 1. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE DRAWINGS FOR LEFT OR RIGHT HAND DRAIN OPENINGS FOR ALL TUB/SHOWER FIXTURES 2. ALL HANDICAP ACCESSIBLE FIXTURES SHALL BE ADA COMPLIANT 3. THE PLUMBING CONTRACTOR SHALL COORDINATE ALL FIXTURE INSTALLATION DIMENSIONS WITH THE ARCHITECTURAL DETAILS ON THE ARCHITECTURAL DRAWINGS 4. HANDICAP ACCESSIBLE APARTMENT UNITS AND PLUMBING FIXTURES ARE NOT SHOWN ON THE PLUMBING DRAWINGS. THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL DRAWINGS FOR ALL HANDICAP ACCESSIBLE APARTMENT UNITS AND ASSOCIATED PLUMBING FIXTURES 5. THE PLUMBING CONTRACTOR SHALL REVIEW THE PROJECT SPECIFICATION SHEETS FOR ADDITIONAL INFORMATION REGARDING THE PLUMBING FIXTURES 6. THE PLUMBING FIXTURES SHALL BE TOTO OR THREE EQUAL MANUFACTURES AMERICAN STANDARD, KOLHER, OR GERBER. 7. ALL PLUMBING FIXTURES, FAUCETS, & FLUSH VALVES SHALL BE FIELD ADJUSTED TO ENSURE PROPER CODE COMPLIANT FOR TEMPERATURE AND FLOW 8. ALL HANDWASHING FIXTURES SHALL BE FIELD ADJUSTED TO LIMIT THE HOT WATER TEMPERATURE TO 110°F. 9. PROVIDE SERVICE STOPS FRO ALL FIXTURES. ALL EXPOSED WATER & WASTE PIPING ASSOCIATED WITH FIXTURES SAHLL BE CHROME FINISH. PROVIDE ALL SUPPLIES, SERVICE STOPS, TAILPIECES, & TRAPS FOR ALL FIXTURES AS REQUIRED. PROVIDE ALL FINAL CONNECTIONS. 10.PROVIDE CONCEALED WALL CARRIERS FOR ALL WALL MOUNTED FIXTURES. CARRIES SHALL BE BY ZURN OR APPROVED EQUAL. 11. PROVIDE PRE -MOULDED INSULATION KITS ON ALL WASTE & WATER PIPING, VALVES & FITTINGS DIRECTLY BELOW ACCESSIBLE FIXTURES. INSULATION KIT TO BE TREBRO FLOOR DRAIN SCHEDULE TAG No. TYPE STYLE OUTLET STRAINER REMARKS MANUFACTURER TOP LIGHT DUTY CAST IRON BODY WITH FLASHING FLOOR DRAIN SHALL BE J.R. SMITH # 2005 OR EQUAL FD1 FLOOR DRAIN CAULK OUTLET 2" 6" SQUARE COLLAR, ADJUSTABLE STRAINER, WITH TRAP PRIMER INLET. PROVIDE TRAP PRIMER SYSTEM FOR EACH FD1 FLOOR DRAIN 1. ALL FLOOR DRAINS SHALL BE PROVIDED WITH FLASHING. FLASHING SHALL BE INSTALLED BY THE GENERAL CONTRACTOR. THE PLUMBING CONTRACTOR SHALL COORDINATE THE FLASHING REQUIREMENTS FOR ALL DRAINS WITH THE GENERAL CONTRACTOR TO INSURE THAT ALL FLOOR DRAINS ARE PROVIDED WITH PROPER FLASHING. 2. THE FLOOR DRAIN SHALL BE J.R. SMITH OR THREE EQUAL MANUFACTURES WATTS, ZURN, OR JOSAM. SEWER CAMERA NOTE THE LOCATION AND SIZE OF THE EXISTING UNDERGROUND SANITARY PIPING INDICATED ON THE PLUMBING DRAWINGS IS APPROXIMATE ONLY AND IS UNKNOWN. THE LOCATION AS INDICATED ON THE PLUMBING DRAWINGS SHALL NOT BE USED IN ANY WAY BY THE PLUMBING CONTRACTOR FOR THE INSTALLATION OF ANY NEW UNDERGROUND PLUMBING WORK. PRIOR TO THE COMMENCEMENT OF ANY WORK AT THE SITE THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A SEWER CAMERA SERVICE THAT WILL CONDUCT A SURVEY OF ALL OF THE EXISTING UNDERGROUND SANITARY SYSTEMS IN THE BUILDING. THE SEWER CAMERA SERVICE SHALL MAP OUT THE EXACT LOCATIONS, SIZES AND INVERT ELEVATIONS OF ALL OF THE EXISTING UNDERGROUND SANITARY SYSTEMS IN THE BUILDING. THE PLUMBING CONTRACTOR SHALL USE THIS SURVEY INFORMATION TO DETERMINE THE EXACT SIZE, LOCATION AND INVERT ELEVATIONS OF THE EXISTING UNDERGROUND SANITARY SYSTEMS AND TO DETERMINE IF THE POINTS OF NEW CONNECTIONS OF THE PROPOSED NEW UNDERGROUND SANITARY SYSTEMS. THE PLUMBING CONTRACTOR SHALL VERIFY THAT THE POINTS OF NEW CONNECTIONS OF THE PROPOSED NEW UNDERGROUND SANITARY SYSTEMS WILL BE COMPATIBLE WITH THE EXISTING UNDERGROUND SANITARY SYSTEMS. THE PLUMBING CONTRACTOR SHALL MAKE WHATEVER MODIFICATIONS TO THE DRAWINGS THAT ARE NECESSARY TO THE PROPOSED NEW UNDERGROUND SANITARY SYSTEMS AS A RESULT OF THIS SURVEY WORK AND COORDINATION AND AT NO EXTRA COST TO THE CONTRACT. ANY WORK THAT IS INSTALLED PRIOR TO THIS COORDINATION THAT HAS NOT BEEN COORDINATED WITH THE SURVEY WORK SHALL BE REMOVED AND REWORKED AT NO EXTRA COST TO THE CONTRACT. 021, ralfaallaNWHmAll__ 1 AFF ABOVE FINISH FLOOR TYPE TYPICAL BLDG BUILDING VTR VENT THROUGH ROOF CW COLD WATER W/ WITH ON DOWN WH NON -FREEZE WALL HYDRANT DWG DRAWING DCO DANDY (RISER) CLEANOUT ECO END CLEANOUT HW HOT WATER V VENT 1 FIXTURE NUMBER SAN SANITARY P.C. PLUMBING CONTRACTOR SO STORM DRAIN FCO FLOOR CLEANOUT IW INDIRECT WASTE G NATURAL GAS YH OUTSIDE NON -FREEZE YARD HYDRANT GC GENERAL CONTRACTOR NTS NOT TO SCALE GENERAL PLUMBING NOTES 1. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH THE MASSACHUSETTS STATE PLUMBING AND FUEL GAS CODE. 2. CAREFULLY COORDINATE LOCATION OF PIPING WITH ALL OTHER TRADES. 3. ALL PIPING SHOWN DIAGRAMMATIC ALLY AND EXACT LOCATION SHALL BE DETERMINED IN THE FIELD. 4. ALL PIPING SHALL BE RUN CONCEALED ABOVE CEILINGS, IN WALLS AND IN CHASES, UNLESS OTHERWISE NOTED. 5. NO STRUCTURAL MEMBERS SHALL BE CUT WITHOUT THE APPROVAL OF THE ENGINEER. 6. ALL PIPING SHALL BE SUPPORTED FROM BUILDING STRUCTURE. 7. RUN WATER PIPE ON THE WARM SIDE OF BUILDING INSULATION. NO WATER PIPING SHALL BE RUN IN EXTERIOR WALLS. 8. PROVIDE DRAW OFFS WITH BALL VALVE, HOSE END VACUUM BREAKER, CAP & CHAIN AT ALL DOMESTIC WATER LOW POINTS AND PITCH PIPING TO DRAIN. 9. ALL SANITARY WASTE PIPING SHALL PITCH A MIN. OF 1/8" PER FT. FOR PIPING 4" & LARGER, 1/4" FOR PIPING UP TO 3". ALL VERTICAL SANITARY LINES TO BE INSULATED, INSULATION AS SPECIFIED. 10. PROVIDE ACCESSIBLE CLEANOUTS AT THE BASE OF ALL STACKS, AS SHOWN, AND AS REQUIRED. 11. ALL PIPING SHALL BE NEW, INSTALLED PARALLEL TO BUILDING LINES AND PITCHED TO LOW POINTS. 12. PLUMBING CONTRACTOR SHALL PROVIDE FIRE STOPPING FOR ALL PENETRATIONS THROUGH ALL FLOORS, FIRE WALLS AND FIRE RATED SEPARATIONS. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR THESE AREAS AND PROVIDE LINK SEAL FIRE STOPPING KITS. 13. PLUMBING CONTRACTOR SHALL BE FURNISH, INSTALL AND MAINTAIN ALL SCAFFOLDING, HOISTING EQUIPMENT, DERRICKS, ETC., NECESSARY FOR INSTALLATION OF WORK. 14. ALL PLUMBING PIPING AND DRAINS SHALL BE KEPT CLEAR OF BLOCKAGE WHILE CONSTRUCTION IS UNDERWAY. ALL PLUMBING PIPING SHALL BE DEBURRED BEFORE JOINTS ARE MADE. 15. ALL CONDITIONS SHOWN ARE APPROXIMATE ONLY. ALL CONDITIONS SHALL BE VERIFIED IN THE FIELD. ALL NEW SYSTEMS SHALL BE COORDINATED WITH ALL CONDITIONS AND TRADES. EXACT LOCATIONS OF ALL CONNECTIONS TO SYSTEMS AND EQUIPMENT SHALL BE DETERMINED IN FIELD. 16. PRIOR TO BID, THE CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL TRADE DRAWINGS AND ALL ASPECTS OF THE WORK AND ALL CONDITIONS TO WHICH THE WORK WILL BE INSTALLED. ANY DISCREPANCIES BETWEEN THE WORK SHOWN ON THE DRAWINGS AND ANY CONDITIONS SHALL BE SUBMITTED TO THE ARCHITECT IN WRITING. 17. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL VENT PIPING THROUGH THE ROOF WITH THE ROOF TOP HVAC EQUIPMENT. ALL VENT PIPES THRU THE ROOF SHALL MAINTAIN THE PROPER DISTANCES FROM ALL HVAC ROOF TOP EQUIPMENT IN ACCORDANCE WITH THE STATE PLUMBING CODE. 18. CAREFULLY COORDINATE LOCATION OF PIPING WITH ALL OTHER TRADES AND ALL CONDITIONS AT THE SITE. 19. DIELECTRIC INSULATING FITTINGS SHALL BE USED WHERE PIPES OF DISSIMILAR METALS ARE CONNECTED, AND AT THE WATER HEATER. 20. THE INFORMATION SHOWN ON THE DRAWINGS IS GENERALLY DIAGRAMMATIC AND IS NOT INTENDED TO INDICATE EXACT ROUTES OF PIPING OR LOCATIONS OF VALVES AND EQUIPMENT. IT SHALL BE THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO DETERMINE THE BEST ROUTES OF PIPING AND LOCATIONS. OF VALVES AND EQUIPMENT IN CONJUNCTION WITH WITH COORDINATION BETWEEN ALL OTHER TRADES AT THE SIGHT. 21. ALL NEW SYSTEMS SHALL BE TESTED, BALANCED AND ADJUSTED TO INSURE PROPER OPERATION AND CODE COMPLIANT INSTALLATION PIPING AND EQUIPMENT SHALL BE TESTED IN ACCORDANCE WITH THE STATE PLUMBING CODE 22. THE CONTRACTOR SHALL BE CAREFUL TO INSURE THAT NO CROSS CONNECTIONS ARE MADE BETWEEN THE POTABLE WATER SUPPLY AND ALL SOURCES OF CONTAMINATION OR CROSS CONNECTION. 23. ALL PIPING MATERIALS, FITTINGS VALVES UNIONS, HANGERS, EQUIPMENT, INSTALLATION AND ALL ASPECTS OF THE PLUMBING WORK SHALL BE AS APPROVED BY THE MASSACHUSETTS STATE PLUMBING AND FUEL GAS CODES 24. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF WALLS AND FLOORS TO ACCOMMODATE INSTALLATION OF NEW PIPING AND EQUIPMENT. CONTRACTOR SHALL PATCH ALL SURFACES TO MATCH THE EXISTING CONDITIONS AND TO THE SATISFACTION OF THE ARCHITECT. 25. PROVIDE SERVICE STOPS FOR ALL FIXTURES 26. SEE PLUMBING FIXTURE SCHEDULES AND DETAILS FOR ALL PIPE SIZES NOT SHOWN ON PLANS, AND FOR ALL PLUMBING CONNECTIONS TO FIXTURES THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO ALL EQUIPMENT REQUIRING PLUMBING 27. THE TERM "CONTRACTOR" SHALL MEAN PLUMBING CONTRACTOR 28. THE CONTRACTOR SHALL CAREFULLY COORDINATE ALL UNDERGROUND PIPING WITH THE FIRE PROTECTION CONTRACTOR TO DETERMINE THE BEST ROUTE FOR ALL UNDERGROUND PIPING 29. PLUMBER SHALL FURNISH AND INSTALL ALL TRAPS, ANGLE STOPS, WASTE ARMS, STRAINERS, TAILPIECES, FIXTURE SUPPLIES AND ALL PLUMBING CONNECTIONS TO ALL PLUMBING FIXTURES REQUIRING PLUMBING AND AS REQUIRED FOR A COMPLETE PLUMBING SYSTEM. 30. ALL PLUMBING FIXTURE TYPES AND LOCATIONS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL HAVE THE APPROVAL OF THE ARCHITECT FOR ALL PLUMBING FIXTURE TYPES, QUANTITIES AND LOCATIONS PRIOR TO PURCHASE 31. THE PLUMBING CONTRACTOR SHALL CREATE A SCALE DRAWING FOR THE BUILDING SHOWING THE LOCATIONS OF ALL BACK FLOW PREVENTION DEVICES AND DETAILS OF THEIR INSTALLATION METHODS. THE PLUMBING CONTRACTOR SHALL ALSO OBTAIN MANUFACTURER CUT SHEETS OF ALL BACK FLOW PREVENTION DEVICES AND SHALL INDICATE THE SIZES AND MODEL NUMBERS BEING USED. THE PLUMBING CONTRACTOR SHALL SUBMIT THESE DRAWINGS AND CUT SHEETS TO THE LOCAL WATER AUTHORITY FOR APPROVAL. NO BACK FLOW PREVENTION DEVICE SHALL BE INSTALLED UNTIL WRITTEN APPROVAL OF ALL BACK FLOW PREVENTION DEVICES HAS BEEN OBTAINED BY THE PLUMBING CONTRACTOR FROM THE LOCAL WATER AUTHORITY. 32. IN THE EVENT THAT THERE ARE DISCREPANCIES BETWEEN PIPE SIZES SHOWN ON THE PLANS VERSUS THAT SHOWN ON THE DETAILS OR RISER DIAGRAMS, THE LARGER PIPE SIZE SHALL BE FOLLOWED. EXISTING SYSTEMS NOTE THE PLUMBING CONTRACTOR SHALL NOT CUT, DISCONNECT OR DEACTIVATE ANY EXISTING PIPING SYSTEMS THAT SERVE ACTIVE FIXTURES IN OTHER AREAS OF THE BUILDING. PRIOR TO CUTTING OR DISCONNECTING OR DEACTIVATING ANY EXISTING PLUMBING PIPING SYSTEMS THE PLUMBING CONTRACTOR SHALL FIELD SURVEY ALL EXISTING PLUMBING CONDITIONS AND SHALL VERIFY THAT NO EXISTING PLUMBING PIPING SYSTEMS THAT SERVE ACTIVE FIXTURES IN OTHER AREAS OF THE BUILDING WILL BE ADVERSELY AFFECTED BY THE PROPOSED WORK. ANY EXISTING PLUMBING PIPING SYSTEMS SERVING ACTIVE FIXTURES IN OTHER AREAS OF THE BUILDING SHALL BE MAINTAINED AND KEPT ACTIVE AT ALL TIMES. SHOULD ANY SUCH EXISTING PLUMBING PIPING SYSTEMS BE CUT OR DISCONNECTED OR SHOULD IT BE NECESSARY TO CUT, DISCONNECT, OR RELOCATE ANY SUCH EXISTING PLUMBING PIPING SYSTEMS OR THEIR ASSOCIATED SUPPLY MAINS OR RISERS THEN THE PLUMBING CONTRACTOR SHALL RECONNECT THESE ACTIVE PLUMBING PIPING SYSTEMS TO THE NEW PLUMBING PIPING SYSTEMS AS SOON AS POSSIBLE IN ORDER TO MAINTAIN SERVICE TO THE ACTIVE AREAS OF THE BUILDING. PRIOR TO PERFORMING THIS WORK THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE BUILDING OWNER FOR THE SHUTTING DOWN AND INTERRUPTION OF THE ACTIVE SERVICES TO THE OTHER AREAS OF THE BUILDING. NO WORK SHALL BE PERFORMED WITHOUT THIS COORDINATION. BL-aw) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection �IENAPI RICHITECT Begin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.com () N 4-J Q) N Q) E 0 Q U U 0 0 0 4--) �> VJ 0 C> 0 1:_j 0 O � U � W l/T v ' > Q E 0 U O 0 � O W QO Plot Date: 8/21/2019 1:22:19 PM D 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: CG Check by: MD Date: 12/18/2019 Scale: As indicated PLUMBING LEGEND, NOTES and SCHEDULES Pool w J Q U U) CV 0 CV \ T T T II t ((JR oJCf) �J z_ 0 CD U Q T W Q CV U UJ rr T W Q w U J Cf) U r-) o Cf) III W Qo o Q -II CV U' T CYO C\1 0 N z U) 1 T W W `i = CD Cn Cf) U_) r C? I I T N91 0 CV LJJ J Q U CD Cn 0 CD I— 00 CD T PLUMBING FIXTURE ADJ SEE PLANS FOR FIXTI FLOOR DRAIN AS INDICATED ON THE FLOOF OUTLET TO SANITARY RAP PRIMER VALVE JTEGRAL AIR GAP OR M BREAKER. PROVIDE S PANEL AT VALVE SUPPLY IN WALL .OW SLAB \"P" TRAP, SEE PLANS FOR SIZES NOTE: 1. TRAP PRIMER SHALL BE BY PRECISION PLUMBING PRODUCT 2. TRAP PRIMER SYSTEMS SHALL BE PROVIDED FOR ALL FLOOR DRAINS NOT DESIGNED TO TAKE THE CONTINUOUS DRIP WASTE FROM EQUIPMENT. WHETHER SHOWN ON THE PLUMBING DRAWINGS OR NOT. NO EXCEPTIONS TO THIS SHALL BE TAKEN. 3. FLOOR DRAINS SHALL BE PROVIDED IN ALL DWELLING UNIT BATHROOMS THAT HAVE AN ADA COMPLIANT ROLL —IN SHOWER FIXTURE. THESE LOCATIONS ARE NOT SHOWN ON THE DRAWINGS, THE PLUMBING CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT FOR THESE LOCATIONS TYPICAL TRAP PRIMER AT FLOOR DRAIN NOT TO SCALE 1 /2" HW SUPPI WOOD OR STEI FRAMING STUD SCREW MOUNTIN BRACKET TO ST TOP OF BOX 3— TOP OF MACE 43" T( JOIST OR BEAM CARBON S' SWIVEL RIN STRAP HAI JOIST OR BEAM KNUT LLEABLE ,N C — CLAMP INE 4DED ROD FOR 2" & SMALLER PIPE TYPICAL WASHING MACHINE BOX NOT TO SCALE FOR 2 1/2" TO 3" PIPE JVIJ I UK IALLEABLE BEAM :LAMP ROD COUPLING (CHINE THREADED ID \RBON STEEL VIVEL RING RAP HANGER NOTE: 1. LOCATE PIPE HANGERS AT JOIST PANEL POINTS. 2 BAND HANGER ��J NOT TO SCALE " VENT ARY TEE FITTING 5AN ITARY FOR 4" & LARGER PIPE 3EAM CLAMP 'LING E THREADED HANGER BL-aw) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC ' Electrical + Plumbing + Fire Protection 'IENAPP ARCHITECTS Begin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com U) N +J Q) N Q) E 0 Q U U 0 0 0 4--) d 0 J 0 U T Q E 0 U O 0 O � O 00 Q0 Plot Date: 8/21/2019 1:22:19 PM D 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: CG Check by: MD Date: 12/18/2019 Scale: As indicated PLUMBING DETAILS P002 T J 0 z 0 0 U Q W J Q U Cn z n LLJ J Q Cf) IZ Q Cl) I- M0Cy'� ) V CV I- 0 (/) W W Cn H 0 O II co W J Q U N 1 O N T r N r 00 It J Q U cn 0 I I T 0 r N \ T O r T CV W J U o U) 0 N 00 \ T EXISTING (3)LAVATORY TO BE REMOVED. ALL ASSOCIATED VALES & SHUT C`« T^ o� REMOVED BACK INTO THE WALL 1 /2" HW & CW PIPING SHALL BE CAPPED IN WALL FOR FUTURE COP EXISTING HOSE BIBB TO BE CUT IN WALL FOR FUTURE C 'ING CON TINU ATION. (TYPICAL 3 3 U 2 W W i i EXISTING (4)URINAL, CARRIERS, & OUTLET PIPING BE REMOVED. ALL ASSOCIATED VALES & SHUT OFF TO BE REMOVED BACK INTO THE WALL, EXISTING EXISTING TOILET TO BE REMOVED. 1" CW PIPING SHALL BE REMOVED ALL ASSOCIATED VALES & SHUT OFF TO BE PLUMBING - Demo Plan SCALE: 1/4"= V-0" ;TING FLOOR DRAINS AND ALL ASSOCIATED VALVES BE REMOVED, HW & CW PIPING, SANITARY, & VENT PIPING BE CUT & CAPPED IN CEILING OR BELOW FLOOR TO THE ROVAL OF THE PLUMBING INSPECTOR. BL-70w) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f.978.428.0067 www.blwengineers.com HVAC *Electrical * Plumbing * Fire Protection lod� olENAPI ARCHITECT egin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.com U) N 4-J r` Q) N Q) E 0 Q U U 0 0 0 +J Q > d 0 .0 J U M0 W Q E 0 � U O 0 i O � O 00 Q0 Plot Date: 8/21/2019 1:22:19 PM 0 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: CG Check by: MD Date: 12/18/2019 Scale: As indicated PLUMBING DEMO PLANS PD1 00 w J Q U o (N 0 T N T T W J Q � U (J o U) V z 0 o CD C) iI Q T LLJ J Q N U U) rzr ^ T L" IL J Q w U J Cn U 0 0 cf) U 0 - W �0 0 T Q II N U/ T `M�M 'J MM N O N z LU Q LLJ U = o U) U) U) T o I I T •el 0 0 N = T 0 T C( 4P (PING CONTINUATIC CONNECT NEW 3" SAN T 4" SAN. EXACT SIZE & LOCAI DETERMINE 1/2" CW UP TRAP PRIMER VA 2" TRAP & SAN 2" VENT PLUMBING - Under Floor Plan SCALE: 1/4"= V-0" BL:W) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC ' Electrical + Plumbing + Fire Protection �IENAP RCHITECTS Sin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 ienapparch itects.com (n N 4-) N E O Q U U O O O 4 0 O Q Q) O� v M T E O C� U > O O O � O co co Plot Date: 8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. 1 05/28/19 Revision Project: 614.14 Drawn by: CG Check by: MD Date: 12/18/2019 Scale: As indicated PLUMBING FLOOR PLANS Pi 00 UO lu''), CV O CV T T T II t oJCf) z 0 CD U Q T w Q CV rr I z T LI'IL J Q w U J Cf) V O U w Qo I o Q -II CV U' T M0Cy'� ) V N 0 N z 1 T W LLJ C) CD U) r O LL T Kol 0 CV w J Q O Cn i O T to w Q U CD Cf) CONNECT NEW HOSE BIBB TO EXISTING 1/2" CW IN WALL. CONNECT (3) NEW 1 1/2" TO TRAP & SAN TO THE EXISTING 2" SANITARY.e CONNECT NEW LAVATORIES TO EXISTING VENT. EXACT LOCATION TO BE DETERMINED IN FIELD. CONNECT (3) EXISTING 1/2" HW & CW TO NEW LAVITARY. NEW SUPPLY & SHUT OFF VALVES TO BE PROVIDED. II (2)1 1/2" TRAP & II II II W W /4P CONNECT NEW 3/4 HW & 1 1/4 CW TO 7T!- 1 1/4 EXISTING 1" HW & 2" CW. EXACT SIZE & LOCATION TO BE DETERMINED IIN FIELD. II II 1/2" HW & CW 2" VENT F 1/2" CW ON TO HOSE CONNECT EXISTING 1" IN WALL TO TO (3)NEW URINAL. EXACT LOCATION & SIZE TO BE DETERMINED IN FIELD. 2" VENT UP CONNECT EXISTING 1" IN WALL TO TO NEW TOILET. EXACT LOCATION & SIZE TO BE DETERMINED IN FIELD. lul I "SAN UP IILIIL�// Boys Toilet r I 2 f' CONNECT (3)NEW URINAL EXISTING 2" SAN 1- -J I �11 � WALL IN WALL. CONNECT NEW URINALS TO EXISTING VENT. EXACT LOCATION & SIZE TO BE DETERMINED IN FILED. ---- ------EXV--------------------- - CONNECT NEW 2" VENT TO j5 SF EXISTING VENT. EXACT SIZE & " CONNECT NEW 2" VENT TO I LOCATION TO BE DETERMINED I EXISTING VENT. EXACT SIZE & IN FIELD. Q5LOCATION TO BE DETERMINED IN FIELD. � oy Is 1/2" HW & C DN. I ' - --� RUN TO (2) L VS L-- - --- r Dress /4„ Toilet I --�,---- -- - I 4" SAN UP 1 o i I et rL-Q— --- -- -- I IT3 Crl I 3)2" VENT RISE 2)1 1/2" TRAP & SAN I 141 SF ----- - HB 2)2" SAN ON & VENT RISE 2)1" CW DN V ~ i 4" SAN U I , 0 Office PIPING CONTINUATION.(TYPICAL CONNECT NEW 1" CW TO EXISTING 2" CW. EXACT SIZE & LOCATION TO BE DETERMINED IN FIELD. CONNECT NEW 1/2" HW & CW TO EXISTING 1 1/2" HW & 2" CW. EXACT SIZE & LOCATION TO BE DETERMINED IIN FIELD. I� i --------- Q-7—EXCWX x-----EXV W W rt� EXISTING COLD & HOT WATER PIPING TO BE VALVED & CAPPED I� CONNECT NEW 2" VENT TO EXISTING VENT. EXACT SIZE & LOCATION 19 TO BE DETERMINED IN FIELD. Boys Dressing Room 637 SF S NEW 1/2" HW & CW TO W & CW. EXACT SIZE & E DETERMINED IN FIELD. — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - - - - - - - - - ------771 ---- - \ " VENT RISE L-- - 1" CW DN SAN UP GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING & PATCHING. PLUMBING CONTRACTOR TO COORDINATE WITH GENERAL CONTRACTOR FOR EXACT LOCATIONS. PLUMBING - Above Floor Plan SCALE: 1 /4"= 1'-0" i St .jage 1I 91SF I I I ' � I I� I I � � 1/2" HW & CW DN & CAPPED. FINAL CONNECTION TO WASHING MACHINE SHALL BE DONE IN THE FUTURE BY OTHERS. 2" VENT RISE) / P // FINAL CONNECTION TO WASHING MACHINE 2" SAN U SHALL BE DONE IN THE FUTURE BY OTHERS. BL-aw) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC ' Electrical + Plumbing + Fire Protection 00�% olENAPP ARCHITECTS Begin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparch itects.com () N 4—J r` Q) N 4) E 0 Q U U 0 0 0 4--) d 0 J 0 U m T Q E U O 0 i 0 � O W Q0 Plot Date: 8/21/2019 1:22:19 PM D 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAYBE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: CG Check by: MD Date: 12/18/2019 Scale: As indicated PLUMBING FLOOR PLANS Pi 01 w U O oJU) 0 `oo U _II U -I Q N U) rr T Q w U J U) U p o Cf) U �co o rr T Q II //�� N �+ ) r co cY) � co C\1 0 N z U) T J w 0 I-- o U) U) r O H r I I r C.1 0 0 r to w J Q U O U) DUCTWORK LEGEND DRAWING NOTES GENERAL NOTES 12 x8 RECTANGULAR DUCTWORK - FIRST DIMENSION IS SIDE SHOWN (IN.) NECK SIZE OR LENGTH IF LINEAR DIFFUSER 1. MECHANICAL WORK INDICATED IS DIAGRAMMATIC. EXACT LOCATIONS OF ALL COMPONENTS ARE TO BE DETERMINED IN THE FIELD (SPACING SUBJECT TO 10 0, 12 x12 EG-A _ SUPPLY/RETURN/EXHAUST REGISTER OR GRILLE ARCHITECT'S REVIEW AND APPROVAL) TO AVOID CONFLICT WITH OTHER TRADES AND EXISTING SITE CONDITIONS. ROUND DUCTWORK -DIMENSION IS DUCT DIAMETER (IN.) 200 CFM AIR VOLUME (CFM) 2. THE CONTRACTOR SHALL VISIT AND CAREFULLY EXAMINE THE SITE TO IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE WORK OF EXISTING DUCTWORK (TYP. OF 3) QUANTITY THIS SECTION. REPORT IN WRITING TO THE ARCHITECT CONDITIONS WHICH MIGHT ADVERSELY AFFECT WORK. NO EXTRA PAYMENT WILL BE PROVIDED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY AN EXPERIENCED OBSERVER. EXISTING DUCTWORK TO BE REMOVED NECK SIZE OR LENGTH IF LINEAR DIFFUSER 12"x12", SD - SUPPLY DIFFUSER DESIGNATION 3. WORK REQUIRING INTERRUPTION OF BUILDING SERVICES SHALL BE CAREFULLY REVIEWED AND COORDINATED WITH THE OWNER TO MINIMIZE FREQUENCY RECTANGULAR SUPPLY DUCTWORK UP 200 CFM AIR VOLUME (CFM) AND DURATION OF SERVICE INTERRUPTIONS. (TYP. OF 3) QUANTITY 'X' RECTANGULAR SUPPLY DUCTWORK DOWN 4. ALL INSTALLATIONS SHALL PERMIT AND PROVIDE ACCESSIBILITY FOR SERVICE AND REPLACEMENT OF ALL NEW EQUIPMENT AND EXISTING EQUIPMENT IMPACTED BY THIS WORK. RECTANGULAR RETURN/EXHAUST DUCTWORK UP ACCU-1 EQUIPMENT DESIGNATION 5. ALL MECHANICAL EQUIPMENT, PIPING, AND DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF GOVERNING LOCAL, STATE, AND ' RECTANGULAR RETURN/EXHAUST DUCTWORK DOWN FEDERAL SEISMIC CODES. PARTICULAR ATTENTION SHALL BE MADE TO VIBRATION ISOLATION, ANCHORING, AND BALANCING REQUIREMENTS. Al DRAWING REVISION NOTE ROUND DUCTWORK UP 6. ALL DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH CODES AND STANDARDS SET FORTH IN NFPA, SMACNA, AND ASHRAE FOR MEDIUM AND LOW e CONNECT TO EXISTING PRESSURE DUCTWORK SYSTEMS. ROUND DUCTWORK DOWN 7. ALL EXPOSED DUCTWORK SHALL BE PAINTED TO MATCH CEILING. REFER TO ARCHITECTURAL DRAWINGS. CAPPED DUCTWORK LIMIT OF DEMOLITION 8. PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCH DUCTS FOR AIR BALANCING. RECTANGULAR TRANSITION REVISION CLOUD 9. ALL DUCTS, PIPES, AND EQUIPMENT SHALL BE INDEPENDENTLY SUPPORTED FROM THE BUILDING STRUCTURE WITH PROPER ALLOWANCES FOR RECTANGULAR TO ROUND DUCTWORK TRANSITION CONTRACTION, EXPANSION, AND VIBRATION ELIMINATION. MITERED ELBOW WITH TURNING VANES 10. ROOM THERMOSTATS SHALL BE MOUNTED 4'-0" ABOVE FINISHED FLOOR UNLESS OTHERWISE SHOWN OR DIRECTED. a NEW SUPPLY DUCTWORK - SINGLE LINE EQUIPMENT TAGS 11. REFER TO SPECIFICATIONS FOR TYPE OF VALVE TO BE USED. VALVES ARE SHOWN ON PLANS FOR PLACEMENT ONLY. �- - NEW RETURN/EXHAUST DUCTWORK - SINGLE LINE 12. ALL DUCT DIMENSIONS SHOWN ARE INSIDE CLEAR FREE AREA REQUIRED. EG EXHAUST GRILLE 13. ALL DIFFUSER, REGISTER, AND GRILLE SIZES INDICATED ON FLOOR PLANS ARE NECK SIZE REQUIRED. EXISTING DUCTWORK -SINGLE LINE ER EXHAUST REGISTER HWS/R HOT WATER SUPPLY/ RETURN PIPING 14. NOT ALL SYMBOLS OR ABBREVIATIONS ARE USED ON THIS PROJECT. �- - - - - EXISTING DUCTWORK TO BE REMOVED - SINGLE LINE RR RETURN REGISTER 15. COORDINATE ENTIRE INSTALLATION WITH THE WORK OF ALL OTHER TRADES PRIOR TO ANY FABRICATION OR INSTALLATIONS. RECTANGULAR SUPPLY DUCTWORK UP - SINGLE LINE SD SUPPLY DIFFUSER UH UNIT HEATER 16. ALL PIPING AND DUCTWORK SHOWN IS DIAGRAMMATIC ONLY. DETERMINE THE EXACT LOCATION IN THE FIELD. RECTANGULAR SUPPLY DUCTWORK DOWN - SINGLE LINE UV UNIT VENTILATOR 17. REVIEW ALL ARCHITECTURAL, STRUCTURAL, PLUMBING, ELECTRICAL, FIRE PROTECTION AND SITE DRAWINGS BEFORE STARTING ANY WORK TO BECOME FAMILIAR WITH THE DETAILS OF CONSTRUCTION, AND COORDINATE WITH OTHER TRADES. �- RECTANGULAR RETURN/EXHAUST DUCTWORK UP - SINGLE LINE 18. OBTAIN ALL REQUIRED PERMITS AND PAY ALL FEES RELATED TO SAME. RECTANGULAR RETURN/EXHAUST DUCTWORK DOWN - SINGLE LINE 19. PROVIDE ALL NECESSARY PIPING, EQUIPMENT AND SUPPORTS AS WELL AS ANY ADDITIONAL EQUIPMENT, ETC. NOT SHOWN ON THE DRAWINGS OR CALLED ABBREVIATIONS ROUND DUCTWORK UP - SINGLE LINE FOR IN THE SPECIFICATIONS BUT NECESSARY TO PROVIDE COMPLETE AND WORKABLE SYSTEMS. ROUND DUCTWORK DOWN - SINGLE LINE 20. PROVIDE ACCESS TO ALL EQUIPMENT REQUIRING PERIODIC SERVICE AND MAINTENANCE. AD ACCESS DOOR 21. DO NOT SCALE THESE DRAWINGS. TAKE ALL MEASUREMENTS IN THE FIELD IN COORDINATION WITH ALL EQUIPMENT AS APPROVED AND WITH ALL OTHER FLEXIBLE DUCTWORK - SINGLE LINE (MAX. LENGTH 5-0") AFF ABOVE FINISHED FLOOR TRADES. ARCH. ARCHITECT ATC AUTOMATIC TEMPERATURE CONTROL 22. ALL DUCTWORK SHALL BE INSTALLED ON ACCORDANCE WITH THE LATEST EDITION OF SMACNA. BOD BOTTOM OF DUCT BTU BTUH BRITISH THERMAL UNIT BRITISH THERMAL UNIT PER HOUR 23. 24. ALL HOT WATER PIPING SHALL BE INSULATED IN ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODE. PROVIDE AIRTIGHT ACCESS DOOR FOR INSPECTION OF FIRE DAMPERS, FILTERS, AND COILS. CONTROL SCHEMATIC LEGEND CAP CFM CAPACITY CUBIC FEET PER MINUTE 25. CONTRACTOR SHALL VERIFY DUCT, PIPING AND EQUIPMENT LOCATIONS FOR INTERFERENCES BEFORE INSTALLATION. T HEAT/COOL THERMOSTAT O DB DRY BULB TEMPERATURE (7) 26. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS. DDC DIRECT DIGITAL CONTROL - - - - - CONTROL LINE DIA. DIAMETER DN DOWN G DRAWING DEMOLITION GENERAL NOTES EAEACH EA EXHAUST AIR PIPING LEGEND EAT ENTERING AIR TEMPERATURE 1. CONTRACTOR SHALL VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT WORK OF THIS SECTION. NO COMPENSATION WILL EC ELECTRICAL CONTRACTOR BE GRANTED FOR ADDITIONAL WORK CAUSED BY UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED ER EXHAUST AIR REGISTER OBSERVERS. HWS HWS HOT WATER SUPPLY ESP EXTERNAL STATIC PRESSURE 2. PRIOR TO COMMENCING WORK OF THIS SECTION, EXAMINE SITE AND CONDITIONS UNDER WHICH WORK WILL BE PERFORMED. DETERMINE EXACT LOCATIONS ETR EXISTING TO REMAIN OF EXISTING EQUIPMENT, PIPING AND CONTROLS. REPORT TO OWNER ANY CONDITIONS THAT MIGHT ADVERSELY AFFECT WORK. COMMENCEMENT OF WORK ---- HWR ---- HWR HOT WATER RETURN EWT ENTERING WATER TEMPERATURE SHALL BE CONSTRUED AS COMPLETE ACCEPTANCE OF EXISTING CONDITIONS AND PREPARATORY WORK. PIPE UP EX. EXISTING 3. ABANDONING OF DUCTWORK, PIPING OR EQUIPMENT IN PLACE SHALL NOT BE ALLOWED. COMPLETE REMOVAL REQUIRED UNLESS NOTED OTHERWISE. EXH EXHAUST PIPE DOWN GC GENERAL CONTRACTOR 4. PIPING TO BE REMOVED: REMOVE PORTION OF PIPING INDICATED TO BE REMOVED AND CAP REMAINING PIPING PIPE BREAK GPM GALLONS PER MINUTE WITH SAME OR COMPATIBLE PIPING MATERIAL. HP HORSE POWER 5. DUCTS TO BE REMOVED: REMOVE PORTION OF DUCTS INDICATED TO BE REMOVED AND CAP REMAINING DUCTS WITH SAME OR COMPATIBLE DUCTWORK HVAC HEATING, VENTILATION AND AIR CONDITIONING MATERIAL. HW HOT WATER KW KILOWATTS 6. EQUIPMENT TO BE REMOVED: DISCONNECT AND CAP SERVICES AND REMOVE EQUIPMENT. AIR DEVICE LEGEND LAT LWT LEAVING AIR TEMPERATURE LEAVING WATER TEMPERATURE 7. EQUIPMENT TO BE REMOVED AND SALVAGED: DISCONNECT AND CAP SERVICES AND REMOVE EQUIPMENT AND DELIVER TO OWNER. MBH THOUSANDS OF BRITISH THERMAL UNITS PER HOUR 8. COMPLY WITH ALL STATE AND LOCAL CODES AS TO REMOVAL AND DISPOSAL OF EQUIPMENT REMOVED FROM THE SITE. ® SD SUPPLY DIFFUSER MECH MECHANICAL 9. COMPLY WITH GOVERNING EPA NOTIFICATION REGULATIONS BEFORE BEGINNING SELECTIVE DEMOLITION. RR RETURN REGISTER NTS NOT TO SCALE OA OUTSIDE AIR 10. REMOVE PREVIOUSLY ABANDONED WORK IN THE WAY OF EXISTING CONSTRUCTION, OR AS NOTED. EG EXHAUST REGISTER OR GRILLE OAT OUTSIDE AIR TEMPERATURE 11. COMPLY WITH HAULING AND DISPOSAL REGULATIONS OF AUTHORITIES HAVING JURISDICTION. PD PRESSURE DROP -- EG/RG SIDEWALL EXHAUST/RETURN GRILLE RA RETURN AIR 12. COMPLY WITH ANSI A10.6 AND NFPA 241. RM SA ROOM SUPPLY AIR 13. PERMITS: GIVE ALL REQUIRED NOTICES, FILE ALL REQUIRED PLANS AND SPECIFICATIONS RELATING TO THE WORK OF THIS SECTION WITH THE PROPER AUTHORITIES AND PAY FOR ANY REQUIRED PERMITS. SF SQUARE FEET SP STATIC PRESSURE 14. ALL AIR-CONDITIONING EQUIPMENT AND SYSTEMS SHALL BE REMOVED DEMOLISHED WITHOUT RELEASING REFRIGERANTS. REFRIGERANT RECOVERY IS TO BE TSTAT THERMOSTAT PERFORMED BY A REFRIGERANT RECOVERY TECHNICAL CERTIFIED BY AN EPA -APPROVED CERTIFICATION PROGRAM. TYP TYPICAL 15. ALL EQUIPMENT AND SYSTEMS TO BE REMOVED OR DEMOLISHED UNDER THIS SECTION AND NOT DESIRED BY OWNER SHALL BECOME THE PROPERTY OF VFD VARIABLE FREQUENCY DRIVE THE CONTRACTOR. THE CONTRACTOR SHALL REMOVE ALL SUCH EQUIPMENT FROM THE SITE PROMPTLY AFTER DETACHMENT FROM BUILDING STRUCTURE. WB WET BULB TEMPERATURE (7) 16. STORAGE OR SALE OF REMOVED ITEMS OR MATERIALS ON -SITE IS NOT PERMITTED. 17. IT IS UNKNOWN WHETHER HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN THE WORK. IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS ARE ENCOUNTERED, DO NOT DISTURB; IMMEDIATELY NOTIFY ARCHITECT AND OWNER. 18. EXISTING PIPING SHOWN ON DRAWINGS DOES NOT INDICATE FULL EXTENT OF PIPING DEMOLITION. FIELD VERIFICATIONS REQUIRED. BLW BLW Engineers, Inc 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection dENAPP RICHITECTS ein Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 glen apparchitects.com 4--d Q) O ::3 Q U U 0 0 0 C) Cf) > 0 � 0 0 +, v °' 0 MOB W /T Q O U/ U � O > 0 0 0 � O UD Q0 Plot Date:8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: BV Check by: WS Date: 12/18/2019 Scale: As indicated HVAC LEGENDS, NOTES AND SPECIFICATIONS 11001 w U O oJU) 0 z_ `oo U - U -I w w Q N U U) rr T Q w U Q U) U p o U co 0 rr T Q II //�� N �+ ) r ICY) .zzj- `o C\l 0 N z U) T J w Q w U = o U) U) U_) CV — r O r I I r C.1 0 0 r to UNIT VENTILATOR SCHEDULE TAG No. LOCATION(S) SERVED MANUFACTURER (AS STANDARD) MODEL No. (AS STANDARD) TYPE FAN DATA HEATING COIL DATA ELECTRICAL DATA REMARKS CFM OA CFM EAT LAT EWT LWT MBH GPM VOLTS PHASE HP MCA/MOCP UV-1 REFER TO DRAWINGS DAIKIN UAHV9H10 CEILING 1000 200 58 90 180 160 40 4.0 115 1 1/3 6.25/15 PROVIDE CONTROL VALVE, DISCONNECT, ECM MOTOR REGISTER, GRILLE & DIFFUSER SCHEDULE TAG TYPE CFM NECK SIZE FRAME TYPE MOUNTING DAMPER MATERIAL FINISH MANUFACTURER & MODEL No. ER/EG EXHAUST REFER TO PLANS REFER TO PLANS SQUARE CEILING/SIDEWALL YES AS PER ARCHITECT AS PER ARCHITECT TITUS / 350RL RR RETURN REFER TO PLANS REFER TO PLANS SQUARE CEILING YES AS PER ARCHITECT AS PER ARCHITECT TITUS / 350RL TG TRANSFER REFER TO PLANS REFER TO PLANS RECTANGLE SIDEWALL NO AS PER ARCHITECT AS PER ARCHITECT TITUS / 350RL NOTES: 1. COORDINATE MOUNTING REQUIREMENTS WITH ARCHITECTURAL REFLECTED CEILING PLANS. 2. COORDINATE FINISH & COLOR WITH ARCHITECT. 3. PROVIDE FRAME SUITABLE FOR SURFACE MOUNTING, CEILING OR SIDEWALL. 4. PROVIDE SQUARE TO ROUND TRANSITIONS WHERE NEEDED. 5. REFER TO DRAWINGS FOR NECK SIZES AND CFM UNLESS NOTED ABOVE. PIPING SCHEDULE SERVICE LOCATION PIPING FITTINGS JOINTS HYDRONIC HEATING, CHILLED WATER COOLING TYPE "L" SEAMLESS COPPER TUBING WROUGHT COPPER, PRESSURE FITTING SWEAT SOLDER & THREADED 2-1/2" AND SMALLER ABOVE GROUND 3" AND LARGER SCHEDULE 40 SEAMLESS BLACK STEEL SCHEDULE 40 SEAMLESS BUTT WELDED WELDED DRAINS TYPE 'L' COPPER WROUGHT COPPER, NO LEAD 95/5 NO —LEAD SOLDER INSULATION SCHEDULE FOR PIPE DIA. (INCHES) LOCATION INSULATION TYPE FITTING INSULATION TYPE RUNOUTS I MAINS < 1" 1 1 1 /4"-2 1 /2" 3"-6" INSULATION WALL THICKNESS (INCHES) HEATING HOT WATER FIBERGLASS WITH ALL FIBERGLASS WITH PVC 1 " 1 1 /2" 2" 2" PIPING HWS & HWR SERVICE JACKET JACKET SUPPLY, RETURN & 2" FIBERGLASS DUCT OUTSIDE AIR DUCT WRAP WITH FSK FACING INSULATION EXHAUST DUCT NONE INSULATION UNIT HEATER SCHEDULE TAG No. MANUFACTURER (AS STANDARD) MODEL No. (AS STANDARD) TYPE AIR DATA HOT WATER CAPACITY ELECTRICAL DATA REMARKS CFM EAT(°F) LAT(°F) EWT(°F) LWT(°F) MBH GPM WPD VOLTS PHASE HP UH-1 STERLING HS-108A HORIZONTAL 245 58 91 180 160 8.0 0.8 0.8 115 1 16 WATTS PROVIDE DISCONNECT, CONTROL VALVE, SUPPORT HANGERS BL7W) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection dENAP RCHITECI in Here. Finish Well] 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com () N 4--d Q) N E 0 ::3 Q U U 0 0 0 C) Cf) > 0 0 0 �--J Q) U 0 M0E W /T Q O U/ U / 1 O 0 O � O W Q0 Plot Date:8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: BV Check by: WS Date: 12/18/2019 Scale: As indicated HVAC SCHEDULES H002 oJU) CD z_ `o CD U iI w w Q N Cn rr T w Q w U Q p CDU) U co 0 lr T Q II C+ ) r co C0 x C\l O N T J w U = o CV — r O r I I r C.� N w J U o � 0 r to w J Q U O 0 TYPICAL HANGER FOR PIPING 3" AND SMALLER —NO SCALE — HANGER ROD INSULATION (VAPOR BARRIER TYPE IS REQUIRED FOR LOW TEMPERATURE PIPE) PIPE PROVIDE HIGH COMPRESSIVE STRENGTH INSULATION INSERT UNDER INSULATION SHIELD INSULATION SHIELD AT HANGER PIPE HANGER DETAILS NOTES: 1. FASTEN FLEX DUCT TO METAL DUCT WITH ADHESIVE & DRAW BANDS. 2. MAXIMUM LENGTH OF "L"=5'-O" ni ir1T rrni I AD Qv EXHAUST/RETURN BRANCH OR MAIN TYPICAL HANGER FOR PIPING 4" AND LARGER —NO SCALE — ALL EXHAUST/RETURN GRILLE REFER TO SPEC AND SCHEDULE FOR TYPE BELLMOUTH FITTING DER ROD INSULATION PIPE WELD SADDLE ROLLER NO SCALE INSTALLATION AT EXHAUST/RETURN GRILLES "I NOTE: 1. POSITION PIPE HANGERS TO BEAR FULL WEIGHT OF PIPING. NO LOAD ON COIL BODY. 2. LOCATE UNIONS AND ARRANGE PIPING TO FACILITATE COIL REMOVAL AND TO AVOID BLOCKING ACCESS DOORS FOR SERVICING OF FILTERS, VALVES, MOTORS, ETC. 3. CONTROL VALVE TO FAIL TO FULL FLOW THROUGH COIL. PRESSURE GAUGE (TYPICAL) CONTROL VALVE COMBINATION BALANCING AND SHUT OFF VALVE THERMOMETER (TYPICAL) 7WL (TYPICAL) HWR� MANUAL AIR VENT AT ALL HIGH POINTS (TYPICAL) � HWS� � BUNION SHUT OFF VALVE (TYPICAL) STRAINER DRAIN VALVE WITH CAP AND CHAIN HOT WATER COIL DETAIL DRAIN VALVE (TYPICAL) R VENT BALANCE VALVE /S S� IG� BALL VALVE NO SCALE DRAIN STRAP ON AQUASTAT UNION (TYPICAL) HORIZONTAL UNIT HEATER DETAIL No SCALE S RETURN AIR DUCTS L BE WRAPPED �NALLY AS PER IFICATIONS. HANGER SIZES FOR RECTANGULAR DUCT LONGEST DIM. HANGER MAXIMUM OF DUCT STRAPS SPACING UP THRU 60" 1 " X 18 GA. 10'-0" 61" THRU 96" 1-1/2"X18 GA. 8'-0" SELF TAPPING CADMIUM PLATED HEX HEAD SHEET METAL SCREW. STRAPS TO BE TIGHT AGAINST DUCT. NO POP RIVETS ALLOWED DUCT STRAP HANGER DETAIL DRYER EXHAUST NOTES: 1. DRYER EXHAUST VENT/HOOD SHALL BE PROVIDED WITH 4" DIAMETER RIGID METAL DUCT CONNECTION. 2. DRYER EXHAUST VENT SHALL BE 4" DIAMETER RIGID METAL DUCT FOR ENTIRE LENGTH, WITH MINIMAL NUMBER OF ELBOWS. 3. DRYER EXHAUST VENT SHALL NOT HAVE SCREEN, GRILL OR OTHER OBSTRUCTION THAT COULD TRAP LINT FROM DRYERS. 4. DRYER CONNECTION BOX SHALL BE PROVIDED AT EACH DRYER. 5. CONTRACTOR SHALL COORDINATE COLOR WITH ARCHITECT. 6. DRYER EXHAUST VENT/HOOD SHALL BE LOCATED MINIMUM OF 3FT HORIZONTALLY FROM OPENINGS (WINDOWS & DOORS). 7. DRYER EXHAUST VENT/HOOD SHALL BE LOCATED MINIMUM OF 1OFT HORIZONTALLY FROM ANY MECHANICAL VENTILATION AIR INTAKE. EXTERIOR VENT 4" EXHAUST DUCT LAUNDRY DRYER (BY OTHERS) TYPICAL OF DRYER BOX MODEL #425 LAUNDRY DRYER EXHAUST DETAIL HOT WATER PIPE PIPING INSULATION (MOLDED FIBERGLASS FITTING COVERS) WOT IAIATDD DIDD EN MESH TAPE IN ADHESIVE JACKET TO HAVE A PRESSURE SEALING LAP ADHESIVE TO ELIMINATE THE USE OF BANDS, ADHESIVES OR STAPLES. NO SCALE IE-PIECE PIPE INSULATION JACKETED WITH AN EMBOSSED VAPOR BARRIER LAMINATE CHILLED/HOT WATER PIPING INSULATION NO SCALE RETURN AIR OUTSIDE AIR LT SUPPLY FAN IS 1 4 r M I [V71 SUPPLY AIR I ECMI I I I I I TO EXISTING EMS APPLICATION — — j L — SPECIFIC L--------------- CONTROLLER --�T APPLICATION TABLE UNIT VENTILATOR UV-1 UNIT VENTILATOR SEQUENCE OF OPERATION THE UNIT VENTILATOR UNIT SHALL BE CONTROLLED THROUGH THE APPLICATION SPECIFIC CONTROLLER & EMS. THE SEQUENCE LISTED BELOW IS REVERSIBLE UNLESS NOTED OTHERWISE. OCCUPIED HOURS: THE UNIT'S SUPPLY FAN SHALL BE ENERGIZED AND OPERATE CONTINUOUSLY. THE OUTDOOR AIR DAMPER SHALL BE OPENED TO THE MINIMUM VENTILATION POSITION (SCHEDULED OA). IF HEATING IS REQUIRED, THE HOT WATER CONTROL VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE SUPPLY TEMPERATURE SETPOINT 70°F (ADJUSTABLE) RESET BY THE SPACE TEMPERATURE. UNOCCUPIED HOURS: THE UNIT'S SUPPLY FAN SHALL BE DE -ENERGIZED. THE HOT WATER COIL VALVE SHALL BE CLOSED AND THE OUTDOOR AIR DAMPER SHALL BE CLOSED. IF HEATING IS REQUIRED, THE SUPPLY FAN SHALL ENERGIZE AND HOT WATER VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE SUPPLY TEMPERATURE SETPOINT 55°F (ADJUSTABLE) UTILIZING 100% RE -CIRCULATED AIR. WHEN THE UNIT'S FREEZESTAT SENSES A LOW TEMPERATURE CONDITION THE UNIT'S SUPPLY FAN AND CONDENSING UNIT SHALL BE DE -ENERGIZED. THE UNIT'S OUTDOOR AIR DAMPER SHALL BE CLOSED AND THE APPROPRIATE ALARM SIGNAL SHALL BE TRANSMITTED TO THE EMS. HOT WATER RETURN (HWR) F--------------------� I I I UNIT HEATER I I LINE VOLTAGE I 7- L__�ZONE SENSOR HOT WATER SUPPLY (HWS) APPLICATION TABLE UNIT HEATER UH-1 HOT WATER UNIT HEATER SEQUENCE OF OPERATION THE SEQUENCE LISTED BELOW IS REVERSIBLE UNLESS NOTED OTHERWISE. UPON A CALL FOR HEAT FROM THE SPACE SENSOR, THE UNITS SUPPLY FAN SHALL BE ENERGIZED AND THE TWO WAY CONTROL VALVE SHALL MODULATE OPEN AS REQUIRED TO MAINTAIN THE OCCUPIED SET POINT. BLW BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection I ENAP RCHITECTS Agin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com (� N 4--d E Q) N � E O Q U E U O O O —J 4 0 Cf) 0 > O 0 O L_ Q) v 0 MOB W /T Q E O U >, O > 0 O O 3: O 00 Q0 Plot Date:8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: BV Check by: WS Date: 12/18/2019 Scale: As indicated HVAC DETAILS & CONTROLS 1 1003 c� oJU) z 0 o U w Q N U U) /zr T w Q w U Q U) U p o U co 0 rT Q II 1l //11 N �+ ' T M0 `CY).zzMM V C\l 0 N z U T J w Q w U = o U) U) U_) CV — r O H T I I T C.1 W 0 T LO w J U O U) FI DU DUCTW( HVAC - Demo Floor Plan SCALE: 1 /4"= V-0" �T r F DU DUCTW( HVAC - Proposed Floor Plan SCALE: 1 /4"= V-0" ;ACT I" BL:W) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t: 978.486.4301 £ 978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection dENAPP RCHITECTS ein Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienapparchitects.com () N 4--d r` Q) N E 0 ::3 Q U U 0 0 0 C) Cf) > 0 0 0 +, °' U 0 M0E W /T Q O U/ U / 1 O 0 O � O W Q0 Plot Date: 8/21/20191:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: BV Check by: WS Date: 12/18/2019 Scale: As indicated HVAC BOYS LOCKER ROOM PLANS 11100 r C) r M W J U O W J � U J O U) 0 z_ n `,' o U U - Q r W J Q N U U) rr T J Q W U Q n o c/) III D � �0 o rr r Q -II N // �+) r C9 ICY') CV O N z U) LU T J LLJ W U I-o U) C/) U) CV - r O H r I I r C.i N W J Q O W 0 r LO W J Q U O U) GENERAL SPECIFICATIONS 1. CONDITIONS OF THE CONTRACT AND DIVISION 1, GENERAL REQUIREMENTS APPLY TO WORK SHOWN ON THESE DRAWINGS. EXAMINE DRAWINGS AND OTHER SPECIFICATIONS FOR REQUIREMENTS THAT AFFECT WORK SHOWN ON THESE DRAWINGS. 2. PROVIDE ITEMS REFERRED TO IN SINGULAR NUMBER IN CONTRACT DOCUMENTS IN QUANTITIES NECESSARY TO COMPLETE WORK. 3. VISIT SITE AND EXAMINE CONDITIONS UNDER WHICH WORK MUST BE PERFORMED. REPORT ADVERSE CONDITIONS IN WRITING TO ARCHITECT. COMMENCEMENT OF WORK SHALL BE CONSTRUED AS COMPLETE ACCEPTANCE OF EXISTING CONDITIONS INCLUDING PREPARATORY WORK DONE BY OTHERS. 4. PERFORM WORK AND PROVIDE MATERIALS AND EQUIPMENT AS SHOWN ON DRAWINGS. COORDINATE ELECTRICAL WORK WITH WORK SHOWN ON THESE DRAWINGS. 5. GIVE NOTICES, FILE PLANS, OBTAIN PERMITS AND LICENSES, PAY FEES AND BACK CHARGES, AND OBTAIN NECESSARY APPROVALS FROM AUTHORITIES THAT HAVE JURISDICTION. 6. PERFORM WORK AS REQUIRED BY CODES, REGULATIONS AND LAWS OF LOCAL, STATE AND FEDERAL GOVERNMENTS AND OTHER AUTHORITIES WITH LAWFUL JURISDICTION. 7. MATERIAL AND EQUIPMENT SHALL BE UL, NEMA, ANSI, IEEE, ADA & CBM APPROVED FOR INTENDED SERVICE. MATERIAL AND INSTALLATION SHALL MEET REQUIREMENTS OF NATIONAL AND STATE ELECTRICAL CODE. 8. MAINTAIN RECORD DRAWINGS ON SITE. RECORD SET MUST BE COMPLETE, CURRENT AND AVAILABLE FOR INSPECTION WHEN REQUISITIONS FOR PAYMENT ARE SUBMITTED. 9. GUARANTEE WORK IN WRITING FOR ONE (1) YEAR FROM DATE OF FINAL ACCEPTANCE. REPAIR OR REPLACE DEFECTIVE MATERIALS OR INSTALLATION AT NO COST TO OWNER. CORRECT DAMAGE CAUSED IN MAKING NECESSARY REPAIRS AND REPLACEMENTS UNDER GUARANTEE AT NO COST TO OWNER. 10. SUBMIT GUARANTEE TO ARCHITECT BEFORE FINAL PAYMENT. STATEMENT OF GUARANTEE REQUIREMENTS SHALL NOT BE INTERPRETED TO LIMIT OWNER'S RIGHTS UNDER LAW AND THIS CONTRACT. 11. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS. PROVIDE INFORMATION AND COMPONENTS SHOWN ON RISER DIAGRAMS BUT NOT SHOWN ON PLANS, AND VICE VERSA, AS IF EXPRESSLY REQUIRED ON BOTH. 12. UTILIZE MOLDED CASE CIRCUIT BREAKERS. MINIMUM INTERRUPTING CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL AT 240 VOLTS, AND 14,000 AMPS SYMMETRICAL AT 480 VOLTS. 13. TEMPORARY LIGHT AND POWER SHALL BE PROVIDED ON SITE BY THE ELECTRICAL CONTRACTOR. COST OF ELECTRICITY SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 14. ADDRESS QUESTIONS REGARDING DRAWINGS TO ARCHITECT IN WRITING BEFORE AWARD OF CONTRACT. OTHERWISE, ARCHITECT INTERPRETATION OF MEANING AND INTENT OF DRAWINGS SHALL BE FINAL. 15. SUBMIT SHOP DRAWINGS AND PRODUCT DATA WITHIN THIRTY (30) DAYS AFTER AWARD OF CONTRACT. CHECK, STAMP AND MARK WITH PROJECT NAMES SUBMITTALS BEFORE TRANSMITTING TO ARCHITECT. INDICATE DEVIATIONS FROM CONTRACT DOCUMENTS. SHOP DRAWINGS SHALL BE PROVIDED FOR ALL EQUIPMENT SHOWN ON THE DRAWINGS. PROVIDE SHOP DRAWINGS ON LIGHTING, PANELBOARDS, CIRCUIT BREAKERS, CONDUIT, WIRING DEVICES, LIGHTING CONTROL DEVICES, CABLE AND CONDUCTORS, FIRE ALARM INCLUDING BATTERY CALCULATIONS, RISER DIAGRAM, EQUIPMENT CUTS AND DISCONNECTS. 16. DEVIATION FROM CONTRACT DOCUMENTS, OR PROPOSED SUBSTITUTION OF MATERIALS OR EQUIPMENT FOR THOSE SPECIFIED, SHALL BE REQUESTED IN SEPARATE LETTER, WHETHER DEVIATIONS ARE DUE TO FIELD CONDITIONS, STANDARD SHOP PRACTICE, OR OTHER CAUSE. 17. SUBSTITUTIONS FOR SCHEDULED LIGHTING EQUIPMENT WILL BE REJECTED UNLESS SUBSTITUTION SUBMITTAL IS RECEIVED WITHIN TEN (10) DAYS AFTER CONTRACT AWARD. 18. SCHEDULE AT LEAST TEN (10) WORKING DAYS, EXCLUSIVE ON TRANSMITTAL TIME FOR SUBMITTAL REVIEW. 19. ALL WIRING SHALL BE RUN CONCEALED UNLESS SPECIFIED OTHERWISE. 20. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, RECTILINEAR TO BUILDING STRUCTURE. 21. LOCATION OF MECHANICAL EQUIPMENT THAT REQUIRE ELECTRICAL CONNECTIONS ARE SHOWN ON THE MECHANICAL DRAWINGS. 22. ALL RACEWAY RUNNING THROUGH BUILDING EXPANSION JOINTS SHALL BE EQUIPPED WITH EXPANSION FITTINGS. 23. CONDUIT HOMERUNS SHOWN ON THE DRAWING WITH MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS ARE SHOWN DIAGRAMMATICALLY. THE CONTRACTOR SHALL NOT INSTALL MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS IN A RACEWAY UNLESS DONE SO STRICTLY BY THE NATIONAL ELECTRICAL CODE AS AMENDED BY THE STATE. 24. THE ELECTRICAL CONTRACTOR SHALL CONSULT AND COOPERATE WITH CONTRACTORS OF OTHER TRADES TO AVOID ANY INTERFERENCE IN THE INSTALLATION OF THEIR RESPECTIVE EQUIPMENT. CONTRACTOR SHALL REVIEW ALL TRADES' CONTRACT DOCUMENTS TO DETERMINE SPECIFIC MOUNTING LOCATIONS FOR ELECTRICAL EQUIPMENT. COORDINATE EXACT MOUNTING LOCATIONS WITH THE ARCHITECT 25. BRANCH CIRCUIT WIRING MAY NOT BE SHOWN GRAPHICALLY ON DRAWINGS AND MAY BE INDICATED BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND EQUIPMENT. PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT INDICATED GRAPHICALLY. PHASE BALANCE ALL PANELBOARDS IN FIELD. CIRCUIT NUMBERS ARE DIAGRAMMATIC, UTILIZE AVAILABLE SPACE OR PROVIDE ADDITIONAL BREAKERS AND PANELBOARDS AS NECESSARY. 26. ALL NEW WIRING SHALL BE TYPE THHN/THWN RATED 75-90-C, 600V. WET -DRY LOCATIONS. MINIMUM BRANCH CIRCUIT WIRING SHALL BE NO. 12 AWG SOLID COPPER. BRANCH CIRCUITS LONGER THAN 150 FEET FOR 120 VOLTS OR 250 FEET FOR 277 VOLTS SHALL BE AT LEAST NO. 10 AWG FROM PANEL TO LAST OUTLET. 27. ALL NEW EXPOSED INTERIOR WIRING ABOVE 8'-0" NOT EXPOSED TO DAMAGE SHALL BE INSTALLED IN ELECTRIC METALLIC TUBING. ALL WIRING IN CONCRETE SLABS OR EXPOSED IN ROOM BELOW 8'-0" OR EXPOSED TO DAMAGE SHALL BE INSTALLED IN RIGID STEEL CONDUIT. EXTERIOR WIRING SHALL BE IN GALVANIZED RIGID METALLIC CONDUIT. 28. INTERRUPTIONS TO EXISTING ELECTRIC SERVICES AND SYSTEMS SHALL BE AS SHORT AS POSSIBLE AND AT A TIME AND DURATION APPROVED BY THE ARCHITECT OR OWNER. INCLUDE ALL PREMIUM TIME ASSOCIATED WITH INTERRUPTIONS TWENTY-FOUR (24) HOUR NOTICE IS REQUIRED. 29. ALL GROUNDING SHALL BE PERFORMED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AS AMENDED BY THE STATE OF MASSACHUSETTS. 30. ALL FIREPROOFING FOR ELECTRICAL PENETRATIONS SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. 31. SYSTEM FEEDERS AND BRANCH CIRCUITS THAT PASS THROUGH ALTERED AREAS AND SERVE OTHER AREAS SHALL BE MAINTAINED. 32. PROVIDE NEW TYPED IDENTIFICATION DIRECTORY IN PANELBOARDS INDICATING CIRCUIT FUNCTION OR EQUIPMENT SERVED. LABEL ALL ELECTRICAL PANELS, DISCONNECT SWITCHES AND OTHER EQUIPMENT WITH ENGRAVED VINYL PLATES. NAMEPLATE LETTERING SHALL BE 1/4" MINIMUM. 33. DISCONNECT SWITCHES SHALL BE HEAVY DUTY (HD). SIDE OPERATED WITH INTERLOCKING COVER, G.E., SQUARE "D", CUTLER HAMMER OR SIEMENS OR EQUAL. 34. ALL WIRING (LOW VOLTAGE, TEL/DATA, FIRE ALARM, POWER BRANCH CIRCUIT) SHALL BE PLENUM RATED; NO EXCEPTIONS. NON -PLENUM RATED CABLES OF ANY KIND SHALL NOT BE PROVIDED. 35. PROVIDE UL LISTED MOLDABLE PUTTY PADS TO SEAL ANNULAR SPACES/PENETRATIONS AROUND ALL JUNCTION BOXES. POWER NOTES 1. ALL CONDUIT, WIRING AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED AND GROUNDED IN ACCORDANCE WITH THE LATEST STANDARDS OF THE NATIONAL & STATE ELECTRICAL CODES AND ANY APPLICABLE LOCAL REGULATIONS. 2. ALL CONDUITS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION AND METHOD OF SUPPORT SHALL BE DETERMINED IN THE FIELD, EXCEPT WHERE SPECIFIC DIMENSIONS AND DETAILS ARE SHOWN. ALL CONDUIT RUNS SHALL BE RIGIDLY SUPPORTED. 3. NO CONDUIT SMALLER THAN 3/4 INCH ELECTRICAL TRADE SIZE SHALL BE USED, UNLESS SPECIFICALLY CALLED FOR ON THE DRAWINGS. 4. PERFORM WORK AND PROVIDE MATERIALS AND EQUIPMENT TO MAKE INSTALLATION COMPLETE IN EVERY DETAIL UNDER THIS CONTRACT WHETHER OR NOT SPECIFICALLY SHOWN ON DRAWINGS. 5. WIRING DEVICES SHALL BE SPECIFICATION GRADE, 20 AMP, WITH SMOOTH NYLON DEVICE PLATES AS MANUFACTURED BY HUBBELL, OR EQUAL. COLOR TO MATCH EXISTING OR AS APPROVED BY ARCHITECT. 6. ALL 15 AND 20 AMP, 125 AND 250 VOLT WIRING DEVICES INSTALLED WITHIN COMMERCIAL KITCHEN AND BAR AREAS SHALL BE PROVIDED WITH WEATHERPROOF IN -USE CLEAR COVER AS MANUFACTURED BY HUBBELL, OR EQUAL: HUBBELL No. MM410C. 7. CONDUCTORS AND CABLE SHALL BE MINIMUM #12 AWG, 600 VOLT, COPPER WITH TYPE THHN/THWN INSULATION. PROVIDE SEPARATE GREEN GROUND IN ALL FEEDERS. WIRE SIZE #8 AWG AND LARGER SHALL BE STRANDED, #10 AWG AND SMALLER SHALL BE SOLID. COLOR CODE CONDUCTORS BLACK, RED, BLUE, WITH WHITE NEUTRAL AND GREEN GROUND EXCEPT AS NOTED FOR 120 VOLT 8. MOUNTING HEIGHTS OF ELECTRICAL EQUIPMENT SHALL BE AS FOLLOWS UNLESS OTHERWISE NOTED: a.) CONVENIENCE RECEPTACLE (GENERAL), 1'-6" FROM FLOOR TO CENTERLINE. b.) CONVENIENCE RECEPTACLE (OFFICE), 1'-6" FROM FLOOR TO CENTERLINE. c.) TELEPHONE OUTLETS, 1'-6" FROM FLOOR TO CENTERLINE. 9. PROVIDE SEPARATE HOT, GROUND AND NEUTRAL CONDUCTOR FOR ALL CIRCUITS CONNECTED TO ARC -FAULT CIRCUIT BREAKERS. GENERAL NOTES 1. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR MOUNTING HEIGHTS AND EXACT LOCATIONS OF ALL DEVICES. 2. ALL FLOOR, MASONRY WALLS AND STRUCTURAL CEILING PENETRATIONS SHALL BE SLEEVED. 3. PROVIDE FIRE/MOISTURE SEAL FOR WALL, FLOOR OR CEILING PENETRATIONS. 4. DO NOT LAY CABLES OR RACEWAY ON, OR SUPPORT FROM SUSPENDED CEILING OR PIPING AND DUCTWORK. 5. OUTLET BOXES SHALL BE MOUNTED FLUSH. CONDUIT SHALL BE RUN CONCEALED. WHERE WALLS ARE BLOCK, DEVICES AND WIRING SHALL BE SURFACE MOUNTED. PROVIDE WIREMOLD OR EQUAL TO SURFACE MOUNTED RACEWAY WITH FINISHED BOXES. 6. ALL WIRING WITHIN UTILITY CLOSETS MAY BE IN SURFACE MOUNTED CONDUIT. EMT MAY BE UTILIZED. 7. FLEXIBLE CONDUIT CONNECTIONS SHALL BE A MAXIMUM OF 6'-0". 8. MC TYPE CONDUCTOR WITH INTEGRAL GROUND WIRE MAY BE UTILIZED FOR POWER AND LIGHTING CIRCUITS. MC CABLE SHALL BE UTILIZED ONLY WHERE COMPLETELY CONCEALED. 9. STEEL OR FIRE -RATED ELECTRICAL BOXES (SWITCHES, OUTLETS, JUNCTION BOXES, ETC.) SHALL BE PROVIDED AND INSTALLED IN ALL FIRE RATED ASSEMBLIES AS IN ACCORDANCE WITH BUILDING AND ELECTRICAL CODES. UL LISTED MOLDABLE PUTTY PADS OR FIREBLOCK/SPRAY FOAM INSULATE SHALL BE USED TO SEAL ALL ANNULAR SPACES/PENETRATIONS AROUND OUTLET BOXES. FIRE RATED ASSEMBLIES INCLUDE EXTERIOR WALLS, FIRE -RATED WALLS, FLOOR/CEILING ASSEMBLIES AND ROOF/CEILING ASSEMBLIES. 10. RECESSED ELECTRICAL ENCLOSURES SUCH AS BUT NOT LIMITED TO; PANELBOARDS, LOW VOLTAGE MEDIA CENTERS, ETC. SHALL BE PROVIDED WITH FIRE -RATED BOXES WHERE INSTALLED IN FIRE -RESISTANCE -RATED ASSEMBLIES. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE -RATED ASSEMBLIES. LIGHTING NOTES 1. ALL CONDUIT, FIXTURES AND OUTLETS ARE SHOWN DIAGRAMMATICALLY. EXACT LOCATION AND METHOD OF SUPPORT SHALL BE DETERMINED IN THE FIELD, EXCEPT WHERE SPECIFIC DIMENSIONS AND DETAILS ARE SHOWN. 2. ALL LIGHTING FIXTURE SPACING DIMENSIONS AND MOUNTING HEIGHTS ARE RECOMMENDED LOCATIONS. SLIGHT VARIATIONS WHERE NECESSARY TO AVOID INTERFERENCE SHALL BE DETERMINED IN THE FIELD. 3. MOUNTING HEIGHTS OF ELECTRICAL EQUIPMENT SHALL BE AS FOLLOWS, UNLESS OTHERWISE NOTED: a.) LIGHT SWITCHES, 4'-0" FROM FLOOR TO CENTERLINE. b.) LIGHTING PANELBOARDS, 6'-6" FROM FLOOR TO TOP. c.) LIGHT FIXTURES - SEE LIGHTING FIXTURE SCHEDULE, MOUNTING HEIGHT OF FIXTURE IS MEASURED TO BOTTOM OF REFLECTOR. 4. WHERE REQUIRED, ADDITIONAL SUPPORT STEEL FOR THE LIGHTING INSTALLATION SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. SEISMIC RESTRAINTS SHALL BE INCLUDED AS PER STATE BUILDING CODE. 5. PROVIDE SEPARATE UN -SWITCHED NEUTRAL TO ALL EXIT SIGNS, EMERGENCY BATTERY UNITS AND EMERGENCY LIGHT FIXTURES CONTAINING EMERGENCY PACKS OR BALLASTS. 6. FOR RENOVATION PROJECTS, PROVIDE NEW BRANCH CIRCUITRY BETWEEN ALL NEW FIXTURES BEING PROVIDED, UNLESS NOTED OTHERWISE ON DRAWINGS. 7. ALL EXISTING FIXTURES TO REMAIN SHALL BE CLEANED AND RE-LAMPED. 8. FIRE -RATED BOXES/ENCLOSURES FOR RECESSED LIGHTING FIXTURES SHALL BE PROVIDED AND INSTALLED IN FIRE -RATED ASSEMBLIES AS IN ACCORDANCE WITH BUILDING AND ELECTRICAL CODES. FIRE -RATED ASSEMBLIES INCLUDE; FIRE -RATED WALLS, FLOOR/CEILING ASSEMBLIES AND ROOF/CEILING ASSEMBLIES. REFER TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE -RATED ASSEMBLIES. DEMOLITION NOTES 1. REFER TO THE ARCHITECTURAL DRAWINGS FOR THE FULL EXTENT OF THE SCOPE OF DEMOLITION. DISCONNECT AND MAKE SAFE ALL ELECTRICAL EQUIPMENT IDENTIFIED FOR REMOVAL ON THE HVAC, PLUMBING AND FIRE PROTECTION PLANS. THE ELECTRICAL SCOPE MAY EXTEND BEYOND THE AREA DEFINED BY THE ARCHITECTURAL DEMOLITION LIMITS TO FULLY COMPLY WITH VARIOUS REQUIREMENTS DEFINED BY THESE NOTES. 2. THE ELECTRICAL DEMOLITION PLANS AND DETAILS INDICATE THE GENERAL INTENT AND ARE NOT INTENDED TO SHOW ALL ITEMS TO BE REMOVED OR RETAINED. THE ELECTRICAL CONTRACTOR SHALL VISIT THE SITE PRIOR TO THE SUBMISSION OF BIDS TO BECOME FAMILIAR WITH THE ACTUAL CONDITIONS AND EXTENT OF WORK. DEVICES AND EQUIPMENT LOCATED ON WALLS AND/OR CEILINGS TO BE REMOVED SHALL BE DISCONNECTED AND MADE SAFE. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OF ANY UNANTICIPATED HIDDEN CONDITIONS ENCOUNTERED DURING DEMOLITION. 3. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ALL SYSTEMS OR BUILDING COMPONENTS DAMAGED DURING THE EXECUTION OF THE WORK. DAMAGE SHALL INCLUDE BUT NOT BE LIMITED TO DESTRUCTION OR DISPOSAL OF ITEMS INTENDED TO REMAIN OR TO BE SALVAGED. 4. THE ELECTRICAL CONTRACTOR SHALL CIRCUIT TRACE AND LABEL ALL EXISTING BRANCH CIRCUITS AND FEEDERS WITHIN THE AREA OF DEMOLITION SCOPE PRIOR TO DE -ENERGIZING AND DISCONNECTION. ALL CIRCUITS WITHIN PANELBOARDS IDENTIFIED FOR REMOVAL SHALL BE TRACED AND LABELED TO ENSURE THAT NO AREA OUTSIDE THE DEMOLITION SCOPE LIMIT IS AFFECTED. 5. THE ELECTRICAL CONTRACTOR SHALL IDENTIFY ALL BRANCH CIRCUITS, FEEDERS AND SYSTEM COMPONENTS, WHICH ARE TO REMAIN WITHIN THE AREA OF DEMOLITION SCOPE. THERE SHALL BE NO INTERRUPTION OF SERVICE TO ANY AREA OUTSIDE THE SCOPE LIMITS WITHOUT APPROVAL FROM THE OWNER'S REPRESENTATIVE. EXISTING EQUIPMENT TO REMAIN SHALL BE LEFT IN A CODE COMPLIANT MANNER. 6. THE ELECTRICAL CONTRACTOR SHALL DE -ENERGIZE AND REMOVE ALL CONDUCTORS AND RACEWAYS TO THEIR POINTS OF ORIGIN WITHIN THE AREA OF DEMOLITION SCOPE. ITEMS IDENTIFIED FOR DEMOLITION SHALL NOT BE ABANDONED IN PLACE. RACEWAYS THAT ENTER MASONRY WALLS AND FLOORS SHALL BE CUT FLUSH AT THE SURFACE FOR PATCHING BY OTHERS. ALL CIRCUIT BREAKERS ASSOCIATED WITH THE DEMOLITION SCOPE SHALL BE DE -ENERGIZED AND LABELED SPARE. 7. THE ELECTRICAL CONTRACTOR SHALL TEMPORARILY SUPPORT ALL ITEMS TO REMAIN THAT ARE AFFECTED BY THE DEMOLITION OF BUILDING STRUCTURAL COMPONENTS (WALLS, CEILINGS, ETC.). TEMPORARILY SUPPORTED ITEMS SHALL BE PERMANENTLY SUPPORTED AND INSTALLED WHEN FINALIZED STRUCTURES ARE IN PLACE. 8. ALL REMOVED ITEMS SHALL BE LEGALLY DISPOSED OF UNLESS IDENTIFIED FOR REUSE. THE OWNER'S REPRESENTATIVE SHALL INSPECT ALL RETAINED ITEMS PRIOR TO PLACEMENT IN THE IDENTIFIED STORAGE LOCATION BY THE ELECTRICAL CONTRACTOR. 9. THE EXISTING FIRE ALARM SYSTEM SHALL REMAIN FULLY FUNCTIONAL DURING THE ENTIRE DEMOLITION AND CONSTRUCTION PERIOD. REUSE OF EXISTING FIRE ALARM SYSTEM RACEWAYS SHALL NOT BE ALLOWED. ALL REQUIRED SYSTEM SHUTDOWNS SHALL BE COORDINATED WITH AND APPROVED BY THE OWNER'S REPRESENTATIVE AND THE AUTHORITY HAVING JURISDICTION. DEMOLITION OF THE EXISTING SYSTEM SHALL NOT COMMENCE UNTIL THE NEW SYSTEM HAS BEEN COMPLETELY INSTALLED, TESTED AND APPROVED BY THE AUTHORITY HAVING JURISDICTION. 10. ALL DEMOLITION SCOPE ASSOCIATED WITH LOW VOLTAGE SYSTEMS INCLUDING BUT NOT LIMITED TO TELEPHONE, DATA, SECURITY, PAGING, CCTV, ETC. SHALL BE INCLUDED IN THIS CONTRACT. 11. REMOVED FLUORESCENT AND HID LAMPS AND BATTERIES SHALL BE RECYCLED BY A FACILITY APPROVED BY THE OWNER'S REPRESENTATIVE. A UNIFORM HAZARDOUS WASTE MANIFEST SHALL BE PREPARED FOR ALL DISPOSALS AND RETURNED WITH ALL APPLICABLE SIGN OFF'S PRIOR TO APPLICATION FOR FINAL PAYMENT. 12. ALL BALLAST IN LIGHTING FIXTURES TO BE DISPOSED SHALL BE VERIFIED TO BE PCB FREE. ALL BALLAST MANUFACTURED PRIOR TO 1979 AND NOT LABELED AS PCB FREE SHALL BE CONSIDERED TO CONTAIN PCBs. PROVIDE WRITTEN VERIFICATION TO THE OWNER'S REPRESENTATIVE THAT CONFIRMS PCB FREE WASTE. WHERE PCB FREE WASTE CANNOT BE VERIFIED, BALLAST SHALL BE RECYCLED BY A FACILITY APPROVED BY THE OWNER'S REPRESENTATIVE, WITH PCB COMPONENTS ELIMINATED BY A HIGH TEMPERATURE INCINERATION. A UNIFORM HAZARDOUS WASTE MANIFEST SHALL BE PREPARED FOR ALL DISPOSALS AND RETURNED WITH ALL APPLICABLE SIGN OFF'S PRIOR TO APPLICATION FOR FINAL PAYMENT. ALL HANDLING SHALL CONFORM TO EPA REQUIREMENTS. PROVIDE BREAKOUT COST FOR THIS SCOPE. ABBREVIATIONS RECEPTACLES AND OUTLETS A/AMP AMPERE IMC INTERMEDIATE METALLIC CONDUIT 5 DUPLEX CONVENIENCE RECEPTACLE OUTLET, GROUNDING TYPE, RATED 20A, 125V TYPE. "5" DENOTES CIRCUIT NUMBER, AC ALTERNATING CURRENT JB JUNCTION BOX MOUNTING HEIGHT 18" TO CENTERLINE AFF AF AMPERE FRAME KVA KILOVOLT -AMPERE AFF ABOVE FINISHED FLOOR KW KILOWATT AFG ABOVE FINISHED GRADE LTG LIGHTING GROUND FAULT INTERRUPTING OUTLET, RATED 20A, 125V RECEPTACLE, MOUNTING HEIGHT 18" TO CENTERLINE AFF AIC AMPERE INTERRUPTING CAPACITY PWR POWER AL ALUMINUM MCB MAIN CIRCUIT BREAKER AT AMPERE TRIP MEC MASSACHUSETTS ELECTRICAL CODE DUPLEX CONVENIENCE OUTLET, MOUNTING HEIGHT 42" TO CENTERLINE AFF OR 6" ABOVE COUNTER TOP ATS AUTOMATIC TRANSFER SWITCH MLO MAIN LUGS ONLY AWG AMERICAN WIRE GAUGE MTG MOUNTING C CKT CONDUIT CIRCUIT MTD MCC MOUNTED MOTOR CONTROL CENTER GROUND FAULT DUPLEX RECEPTACLE, MOUNTING HEIGHT 42" TO CENTERLINE AFF OR MOUNTED 6" ABOVE COUNTER TOP CB CIRCUIT BREAKER NEC NATIONAL ELECTRICAL CODE CU COPPER NS NON -SYSTEM CL CENTERLINE NITS NOTSCALE DC DIRECT CURRENT No., # NUMBER ER MOTOR AND CONTROLS DE DUAL ELEMENT PC PLUMBING CONTRACTOR DWG DRAWING RPM REVOLUTIONS PER MINUTE EC ELECTRICAL CONTRACTOR RMS ROOT MEAN SQUARE VALUE 1.5 MOTOR, NUMERAL INDICATES HORSEPOWER EMH ELECTRICAL MANHOLE RGS RIGID STEEL CONDUIT EWC ELECTRIC WATER COOLER SF SQUARE FOOT EMT ELECTRIC METALLIC CONDUIT SN SOLID NEUTRAL 3R DISCONNECT SWITCH, NON -FUSIBLE TYPE, RATED 30A/3P, IN NEMA TYPE "1" ENCLOSURE, UNLESS OTHERWISE NOTED. FLMT FLEXIBLE LIQUID TIGHT METALLIC TUBING ST SHUT TRIP CIRCUIT BREAKER "3R" DENOTES NEMA TYPE ENCLOSURE GC GENERAL CONTRACTOR SWBD SWITCHBOARD GND GROUND TYP TYPICAL GF GROUND FAULT CIRCUIT BREAKER V VOLTS 30AF DISCONNECT SWITCH, FUSED TYPE, RATED 30A, 20A FUSE, 3 POLE IN NEMA TYPE "1" ENCLOSURE, UNLESS OTHERWISE GFI GROUND FAULT INTERRUPTING VA VOLT-AMPERE 20AT NOTED HVAC HEATING, VENTILATION AND AIR CONDITIONING VFD VARIABLE FREQUENCY DRIVE HP HORSEPOWER WP WEATHERPROOF BRANCH CIRCUIT AND FEEDER SYMBOLS BRANCH CIRCUIT OR FEEDER CONCEALED UNLESS OTHERWISE NOTED. BRANCH CIRCUIT DIAGONAL LINES INDICATE ## NUMBER OF CONDUCTORS, GROUND WIRES) NOT INDICATED. MINIMUM SIZE CONDUCTOR #12 AWG AND 3/4" CONDUIT, UNLESS OTHERWISE NOTED 4#1,1#6G-1%"C INDICATES (3) #1 AWG(PHASE), (1)#1 AWG(NEUTRAL), (1) #6 GROUND IN A 1-1/2" CONDUIT fti FLEXIBLE CONNECTION TO MOTOR OR EQUIPMENT PP1-1 HOMERUN TO PANELBOARD 'P1' CIRCUIT NUMBER 1. DIAGONAL LINES INDICATE (1) PHASE AND (1) NEUTRAL 20A/1P CONDUCTOR. (1) GROUNDING CONDUCTOR UNDERSTOOD. PP1-1,3 HOMERUN TO PANELBOARD 'P1' CIRCUIT NUMBER 1 & 3. DIAGONAL LINES INDICATE (2) PHASE AND (2) NEUTRAL (2)20A/1P CONDUCTOR. (2) GROUNDING CONDUCTOR UNDERSTOOD. PP1-1,3,5 HOMERUN TO PANELBOARD 'P1' CIRCUIT NUMBER 1, 3 & 5. DIAGONAL LINES INDICATE (3) PHASE AND (3) NEUTRAL (3)20A/1P CONDUCTOR. (3) GROUNDING CONDUCTOR UNDERSTOOD. PP1-1,3,5 HOMERUN TO PANELBOARD 'P1' CIRCUIT NUMBER 1, 3 & 5. DIAGONAL LINES INDICATE (3) PHASE AND (1) NEUTRAL 20A/3P CONDUCTOR. (1) GROUNDING CONDUCTOR UNDERSTOOD. PP1-1,3,5 HOMERUN TO PANELBOARD 'P1' CIRCUIT NUMBER 1, 3 & 5. DIAGONAL LINES INDICATE (3) PHASE CONDUCTORS. 20A/3P NEUTRAL CONDUCTOR NOT REQUIRED. (1) GROUNDING CONDUCTOR UNDERSTOOD. SWITCHING SYMBOLS S SINGLE POLE SWITCH, RATED 20A, 120/277V, MOUNTING HEIGHT 48" TO CENTERLINE OF TOGGLE SWITCH IN "ON" POSITION, "a" DENOTES FIXTURE SWITCH CONTROL S THREE WAY SWITCH, RATED 20A, 120/277V, MOUNTING HEIGHT 48" TO CENTERLINE OF TOGGLE SWITCH IN 'ON - POSITION, POSITION, "a" DENOTES FIXTURE SWITCH CONTROL S FOUR WAY SWITCH, RATED 20A, 120/277V, MOUNTING HEIGHT 48" TO CENTERLINE OF TOGGLE SWITCH IN "ON" a POSITION, "a" DENOTES FIXTURE SWITCH CONTROL MANUAL MOTOR STARTER, RATED 20A, 250V, COORDINATE MOUNTING HEIGHT IN FIELD, MOUNTING HEIGHT SHALL NOT SM EXCEED 6'-7" AFF LIGHTING FIXTURE SYMBOLS A U LIGHTING FIXTURE, CEILING/SURFACE/RECESSED/PENDANT OR WALL MOUNTED. "A" DENOTES LIGHTING FIXTURE TYPE A a (SEE FIXTURE SCHEDULE), "2" DENOTES CIRCUIT NUMBER, "a" DENOTES SWITCH CONTROL 2 Eg EMERGENCY BATTERY UNIT WITH TWO (2) HEADS lm} EXIT SIGN, SHADED REGION INDICATES FACE EXISTING EQUIPMENT DESIGNATIONS X EXISTING TO BE REMOVED. REMOVE ALL ASSOCIATED CONDUIT AND CONDUCTORS. XM EXISTING TO REMAIN. XN EXISTING EQUIPMENT TO BE REPLACED WITH NEW. CONNECT NEW EQUIPMENT TO EXISTING CIRCUIT. XR EXISTING EQUIPMENT TO BE RELOCATED. JUNCTION AND EXTEND EXISTING CONDUIT AND CONDUCTORS. XL NEW LOCATION FOR EXISTING EQUIPMENT. JUNCTION AND EXTEND CONDUIT AND CONDUCTORS AS REQUIRED. OCCUPANCY SENSORS WALL MOUNTED OCCUPANCY SENSOR, 180% 300SF COVERAGE (20'W x 251), PHILIPS LIGHTING CONTROLS No. ITS2U-COLOR OR EQUAL CEILING MOUNTED OCCUPANCY SENSOR, 360- TWO-SIDED, 1950SF COVERAGE (50' DIAMETER), PHILIPS LIGHTING * CONTROLS No. ITSCS (FOR PARTIAL COVERAGE APPLICATIONS, A PROVIDED MASK CAN BE TRIMMED TO ADJUST COVERAGE) OR EQUAL * COVERAGE DIMENSIONS APPLY TO DEVICE BEING CENTERED. ACTUAL COVERAGE'S CAN VARY ON THE SHAPE AND USE OF APPLICABLE SPACE. COVERAGE MAY BE REDUCED IF DEVICE IS MOUNTED GREATER THAN 12 FEET HIGH. SENSORS REQUIRE RELAY PACKS, PHILIPS LIGHTING CONTROLS No. ITSRPI U (SINGLE CIRCUIT), ITSRP2 (TWO CIRCUIT) OR ITSRP4 (FOUR CIRCUIT). MISCELLANEOUS ECH MECHANICAL EQUIPMENT TAG, REFER TO MECHANICAL SCHEDULE BLW, BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC *Electrical * Plumbing * Fire Protection ENAPP ARCHITECTS Begin Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienap parchitects.com (n N Q N E O Q O O O _J 0- +, 0 C U > o O+) O O U �--� W I E Q O CIS U � O O O >� O 00 Plot Date:8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: MG Check by: MG Date: 12/18/2019 Scale: As indicated ELECTRICAL LEGEND, NOTES AND SPECIFICATIONS E001 r C) M W J Q � U J O U) z n Qo U Q r W J Q N U U) rr T W U J U) U n o Cf) III D � �0 o rr r Q _II N // �+) r C9 ICY') X CV O N z U) T J w 0 I-- o U) U) CV — r O H r I I r C.i W O r LO w J Q U O U) LIGHTING FIXTURE SCHEDULE MANUFACTURER LIGHT SOURCE FIXTURE TYPE DESCRIPTION AND CATALOG VOLTAGE NUMBER No. WATTAGE T TYPE LT 1 LED 2'X4' DIRECT/INDIRECT MBIAHL LIGHTING: - 45 LED 120 LO a A12125SF-EU-FA LT2 LED 2'X2' DIRECT/INDIRECT COLUMBIA LIGG I - 33 LED 120 FA-SFA-EU-G2 LR 1 9' LED RECESSED DOWNLIGHT LITEFRAME: LC8HL-8LCHL45L35K - 52 LED 120 EXTERIOR RATED REMOTE EMERGENCY HEAD WITH INDOOR POWER MODULE EXITRONIX # REN2BB-WP 2 3.6 LED 120 Eg WALL MOUNTED EMERGENCY BATTERY UNIT WITH TWO (2) HEADS EXITRONIX # NFT-HO-W-G2 2 5.4 LED 120 ®SINGLE FACE EDGELIT EXIT SIGN, REFER TO FLOOR PLANS FOR DIRECTIONAL ARROWS EXITRONIX # 1 4 LED 120 AND MOUNTING TYPES (WALL/CEILING) FACE EDGELIT EXIT SIGN, REFER TO FLOOR PLANS FOR DIRECTIONAL ARROWS S902-WB-SR-RC-BA 1 4 LED 120 eDOUBLE EXITRONIX # MD MOUNTING TYPES (WALL/CEILING) S903-WB-SR-RM-BA LIGHTING FIXTURE NOTES: 1. ALL RECESSED FIXTURE TRIMS TO BE PAINTED TO MATCH CEILING. 2. PROVIDE A COMPLETE AND OPERABLE SYSTEM INCLUDING ALL NECESSARY MOUNTING HARDWARE, POWER FEEDS, WIRING CONNECTIONS, DRIVERS, AND CONTROL INTERFACES. 3. PAINT ALL FLANGES INSTALLED IN DRYWALL TO MATCH ADJACENT CEILING FINISH. FLANGES SHALL BE REMOVED FROM CEILING PRIOR TO PAINTING, OR RAZOR CUT AFTER PAINTING TO ALLOW FOR REMOVAL OF THE TRIM FROM THE CEILING. * ELECTRICAL CONTRACTOR SHALL PROVIDE DIMMABLE LED REPLACEMENT LAMPS, LAMP COLOR TEMPERATURE 2700K, AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE. ** ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS FOR A COMPLETE AND OPERATIONAL TRACK SYSTEM. FINISHED CEILING COMBINATION HOUSING CEILING SPEAKER 8'-6„ - *6" o ** 8'-0" FIRE ALARM AUDIOVISUAL DEVICE * WHICHEVER IS LOWER 0 \-EXIT * 7'-6" ® U SIGN WALL SPEAKER **6-8 -- - - _ � u� ---- CLOCK EMERGENCY BATTERY UNIT 1'-6" MIN FROM ANY INTERIOR CORNER FIRE ALARM VISUAL DEVICE ** NOT GREATER THAN 96" 6'-0" NOT LESS THAN 80" TOP OF HANDLE O 5'-0" WALL TELEPHONE � - o 4'-6" a — — ®� INTERCOM COUNTER HEIGHT RECEPTACLE 4'-0" a E] DISCONNECT SWITCH 3'-6" PANELBOARD -/ LIGHT SWITCH/DIMMER FIRE ALARM PULL STATION RECEPTACLE CAN OUTLET 1'-6" LJ \_ TELE DATA OUTLET / FINISHED FLOOR O1 DEVICE MOUNTING HEIGHT DETAIL N.T.S. 3-1/8" ON 2-3/4" - - t 5/32" DIA HOLE PNL H41A CKT #1,2,3 1 J 1/2" LIGHTING PANEL 1" 1 Q LP1 Q T 480/277, 30, 4W 1 OFF 1/8" LETTERS Z FUSED DISCONNECT SWITCH ❑J NON -FUSED DISCONNECT SWITCH NOTES: NOTES: 1. NAMEPLATE TO BE CONSTRUCTED OF 1/16" THICK WHITE SURFACE WITH LETTER 1. AT A MINIMUM, ELECTRICAL CONTRACTOR SHALL PROVIDE TYPED LABELS WITH PTOUCH ENGRAVED INTO BLACK LAMINATIONS. MACHINE TO INDICATE PANEL NAME AND CIRCUIT NUMBER. PROVIDE 'EMERGENCY' TYPED LABEL FOR CIRCUITS CONNECTED TO EMERGENCY PANELS. COORDINATE EXACT NAMING 2. ALL NAMEPLATES SHALL BE SECURED BY MACHINE SCREWS. WITH PERSONNEL. IF FACILITY STANDARD IS ENGRAVED COVERPLATES, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ENGRAVED COVERPLATES TO MATCH FACILITY 3. NO NAMEPLATES SHALL BE PASTED ON. REQUIREMENTS. O2 TYPICAL NAMEPLATE DETAIL N.T.S. OFUSED DISCONNECT LABELING DETAIL N.T.S. PROVIDE COVERPLATE AND COMMERCIAL GRADE RECEPTACLE, COLOR TO BE INDICATED BY ARCHITECT NOTE 1 PNL R251, CKT #16 qp DUPLEX RECEPTACLE NEMA 5-20R NOTES: 1. AT A MINIMUM, ELECTRICAL CONTRACTOR SHALL PROVIDE TYPED LABELS WITH PTOUCH MACHINE TO INDICATE PANEL NAME AND CIRCUIT NUMBER. COORDINATE EXACT NAMING WITH FACILITY'S PERSONNEL. IF FACILITY STANDARD IS ENGRAVED COVERPLATES, THE ELECTRICAL CONTRACTOR SHALL PROVIDE ENGRAVED COVERPLATES TO MATCH FACILITY REQUIREMENTS. ®TYPICAL RECEPTACLE LABELING DETAIL N.T.S. 1000) LW BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC *Electrical * Plumbing * Fire Protection �IENAP RCHITEC7 in Here. Finish Well] 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienap parchitects.com (n N Q O Q O O O cf) 0 > O O O4� O� v M I > E Q O CIS U O > O O � O 00 Plot Date:8/21/2019 1:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERMISSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: MG Check by: MG Date: 12/18/2019 Scale: As indicated ELECTRICAL FIXTURE SCHEDULE AND DETAILS E002 T W J Q }- U o J co C� z 0 o� C,)- 0CD U T U _II W I Q N U Cf) (zr T W Q w U Q U) U o C0 U o rr T Q II /l1' N v ) T Q�0 co MM CV I- 0 N z T J W Q W U = o U) U) U_) T O H T I I T K01 C.i N LL J Q U O U) O N T T NOTES: 1. FIELD VERIFY EXISTING EMERGENCY LIGHTING INVERTER DOES NOT SERVE REMOTE EMERGENCY LIGHTING HEADS OUTSIDE SCOPE OF WORK AREA AND REMOVE AS INDICATED. COORDINATE RELOCATION WITH ARCHITECT IF INVERTER IS STILL BEING UTILIZED. O T B L:W) BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t:978.486.4301 f:978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection �IENAP RCHITEC7 in Here. Finish Well 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 iena pparchitects.com (n N 4-d r__- C 4) N Q) E O Q 0 0 0 — 4-J 0 C� > O 0 04-1 aJ 0 E U O M I U) > E E 0 U O O > 0 ° � O 00 Q0 Plot Date: 8/21/20191:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERM SSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: MG Check by: MG Date: 12/18/2019 Scale: As indicated ELECTRICAL DEMOLITION PLAN ED1 00 W J � U J O U) C �5 z_ n O ``) o U -�I U -I Q T W J Q N U U) I /zr T W J Q W U Q 0 0 III D co 0 rr T Q N //�� �+ ) T Q0ry') { MM V `'J CV 0 N z U_) T J W C) I-- o U_) CV — T O H T I I T C.i W 0 T LO W J Q U O NEW RECEPTACLES � R L .0 LT1 LT oy T1 Boy's y oil t C Toilet N CT TO EXISTING BRIINCH CIRCUITRY rl - __FL r 165 SF Boy's Boy's Jan. Dress Jan. Dress 23 SF LT2 � LT, LT1F7 00, Toilet 23 SF Toilet r r T o EXISTING 141SF 141SF I U I I I rIAKIKI BRANCH CIR UTRY I—FIA, I I I I I I I I I LT1 a LT1]Ro a LT1 a 's Boy's ing Dressing SM PP-12-390 m Room a20A/1P LT1 637 SF 637 SF O0 CONNECT NOY RECEPTACLES CONNECT TO E I ING LT1 a a �TO EXISTING L IRCUIT. BRANCH CIRCUI COORDINATE N FIELD. TO EX 0 OO BRANCHTCIRCUTRYING O 0 BRANCH CIRCUITRY LT1 a LT1 a LT, Office Office • 128 SF 128 SF CONNECT TO EXISTING ( LT1 b ° BRANCH CIRCUITRY LT2 LT1 LT1 LT1 b LT1 b T1 LT1 ' Stora a CONNECT NEW Storage • RECEPTACLES TO CON CT T EXISTING EXISTING LOCAL CIRCUIT. Ell CIRCUITRY COORDINATE IN FIELD. 139 S 139 SF PP_124#PP-12-#### UH 20A/1P 1 30A/2P 1 I (2 #10&(1)#lI 4"CI CONNECT TO EXISTI G S M� L1RANCH CIRC TRY 20A/ P 1 _ TO BE CONFIRMED WASHER/DRYER CONNECTIONS NOTES: j)LIGHTING PLAN POWER PLAN O PROVIDE NEW 20A/1P BREAKER IN EXISTING SPACE IN PANEL PP-12. SCALE: 1/4"= 1'-0" SCALE: 1/42"= 11-OII CONFIRM AVAILABLE CIRCUIT BREAKERS PRIOR TO ROUGH -IN. NOTES: 1. ALL LIGHTING SHALL BE CONNECTED TO EXISTING BRANCH CIRCUIT IN AREA. PROVIDE ALL BRANCH CIRCUIT WIRING NECESSARY ol B L:W BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t: 978.486.4301 £ 978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection �IENAP RCHITEC7 in Here. Finish Well] 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 iena p parchitects.com (n N Q N E 0 Q 0 0 0 4-J U 0 0 0 — U M I /^4� V / E O CIS U 0 > 0 I� O � O 00 Plot Date: 8/21/20191:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERM SSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: MG Check by: MG Date: 12/18/2019 Scale: As indicated ELECTRICAL LIGHTING AND POWER PLANS El 00 LU J � U J O U) 0 z_ n Qo U -I U -I Q r W J Q N U U /zr In T W J Q w U Q Q O III D no rr r Q N //�� �+ ) r Q0ry') { MM V `'J CV O N z U T J W Q W U = o U) C/) U CV — r O H r I I r C.i CV w J Q U O U) W O r LO FIRE ALARM NOTES 1. THE ELECTRICAL CONTRACTOR SHALL COMPLETE A CERTIFICATE CERTIFYING THAT THE SYSTEM HAS BEEN 100 PERCENT TESTED AND FUNCTIONS IN COMPLETE COMPLIANCE WITH THE SYSTEM SPECIFICATIONS AND MANUFACTURER'S RECOMMENDATIONS. THE CERTIFICATE SHALL BE SIGNED BY THE INSTALLER, ELECTRICAL CONTRACTOR AND THE OWNER. AFTER RECEIPT OF THE CERTIFICATION, THE FIRE PREVENTION OFFICER AND/OR THE FIRE ALARM SUPERVISOR WILL CONDUCT AN INSPECTION IN THE COMPANY OF THE INSTALLER AND A REPRESENTATIVE OF THE OWNER WITHIN SCOPE OF WORK PLUS 10% OF EXISTING. 2. ALL PULL STATIONS MUST BE OF THE DOUBLE ACTION TYPE. BREAKGLASS RODS WILL NOT BE PERMITTED. 3. ALL FIRE ALARM VISUAL DEVICES SHALL BE SYNCHRONIZED. 4. ALL WIRING METHODS SHALL BE AS APPROVED BY THE WIRING INSPECTOR AND THE FIRE DEPARTMENT. ALL FIRE ALARM CABLE SHALL BE PLENUM RATED. 5. ALL SYSTEM COMPONENTS SHALL BE UL LISTED. IF EXISTING EQUIPMENT IS BEING UTILIZED ALL COMPONENTS MUST BE UL LISTED COMPATIBLE WITH EXISTING. 6. ALL WIRING SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE, NFPA 72 SERIES PAMPHLETS, AND ALL STATE AND LOCAL CODES. 7. THE ELECTRICAL CONTRACTOR MUST OBTAIN AN ELECTRICAL PERMIT FROM THE TOWN BUILDING DEPARTMENT AND A PERMIT FROM THE FIRE DEPARTMENT PRIOR TO COMMENCEMENT OF EQUIPMENT INSTALLATION. A FLOOR PLAN SHOWING ALL ALARM DEVICES, LOCATION OF MASTER BOX, PANELS, ANNUNCIATORS, A ONE -LINE WIRING DIAGRAM AND AN ANNUNCIATOR DETAIL SHOWING ZONE LABELING WILL BE REQUIRED TO BE SUBMITTED BEFORE THE FIRE DEPARTMENT ISSUES A PERMIT. 8. INSTALLATION OF EQUIPMENT SHALL BE IN ACCORDANCE WITH CURRENT STANDARDS AND SPECIFICATIONS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 9. ALL FIRE ALARM EQUIPMENT, INSTALLATION AND OPERATION SHALL BE IN CONFORMANCE WITH THE LOCAL FIRE DEPARTMENT INSTALLATION REQUIREMENTS AND SYSTEM INSTALLATION GUIDELINES. 10. ALL EQUIPMENT SHOWN ON DRAWINGS IS DIAGRAMMATIC. 11. PROVIDE AND INSTALL ALL NECESSARY WIRE, CONDUIT, RELAYS AND CONNECTIONS FROM ALL DUCT SMOKE DETECTORS TO THEIR ASSOCIATED RETURN AND SUPPLY FAN CONTROLLERS. UPON ACTIVATION OF A DUCT SMOKE DETECTOR, IN ADDITION TO SOUNDING THE GENERAL ALARM, THE DUCT SMOKE DETECTOR SHALL IMMEDIATELY SHUT DOWN THE ASSOCIATED FAN. 12. THE FIRE ALARM SYSTEM SHOP DRAWINGS SHALL BE REVIEWED AND APPROVED BY BOTH THE ENGINEER AND THE LOCAL FIRE DEPARTMENT. THE SHOP DRAWINGS MUST BE SIGNED OFF BY THE FIRE DEPARTMENT AND ENGINEER PRIOR TO ORDERING AND INSTALLATION OF EQUIPMENT. 13. ABSOLUTELY NO CONNECTIONS WILL BE MADE TO THE MUNICIPAL FIRE ALARM CIRCUITS, EXCEPT BY LOCAL FIRE DEPARTMENT PERSONNEL. 14. ALL WORK BEYOND THE MASTER BOX AND INSIDE OF THE BUILDING SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 15. ALL JOINTS AND CONNECTIONS SHALL BE IN JUNCTION BOXES. ALL CONNECTIONS NOT ON APPROVED TERMINAL STRIPS SHALL BE SOLDERED AND TAPED. ALL JUNCTION BOXES SHALL BE PAINTED RED. 16. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR THAT ALL CONNECTING WIRING MAINTAIN ELECTRICAL INTEGRITY, WITH NO OPEN CIRCUITS, GROUNDS, LEAKAGE OR OTHER FAULTS. CONNECTION TO THE MUNICIPAL SYSTEM WILL NOT BE PERMITTED IF ANY FAULTS EXIST, AND THE CONTRACTOR HAS THE PERMANENT RESPONSIBILITY FOR THE MAINTENANCE OF ALL SUCH WIRING FOR A ONE-YEAR PERIOD. IF FAULTS DEVELOP AFTER INSTALLATION, CORRECTION MUST BE MADE BY THE CONTRACTOR FOR A PERIOD OF ONE YEAR AFTER THE DATE OF FINAL COMPLETION. THE FIRE DEPARTMENT MAY REQUIRE DISCONNECTION OF THE FIRE ALARM BOX FROM THE MUNICIPAL SYSTEM UNTIL PROPER CONNECTIONS AND/OR REPAIRS ARE MADE. SUCH A DISCONNECTION MAY REQUIRED A FIRE WATCH DURING THAT TIME THE BUILDING IS WITHOUT A MASTER FIRE ALARM BOX AND ALARM SYSTEM. THIS FIRE WATCH WILL BE AT THE FIRE DEPARTMENT'S DIRECTION AND PAYMENT FOR SUCH A WATCH WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 17. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL REQUIRED POWER SUPPLIES FOR A COMPLETE AND OPERATIONAL SYSTEM. POWER SUPPLY CALCULATIONS SHALL BE INCLUDED IN FIRE ALARM SUBMITTAL. 18. ALL EQUIPMENT SHALL BE MADE AVAILABLE FOR TEST AND INSPECTION WHEN REQUIRED BY THE FIRE DEPARTMENT. 19. ALL EQUIPMENT USED SHALL BE OF A TYPE APPROVED BY THE FIRE CHIEF THROUGH THE ALARM SUPERINTENDENT AND THE FIRE PREVENTION OFFICER. 20. ALL SYSTEMS SHALL BE DC, SUPERVISED, BATTERY STANDBY FIRE ALARM SYSTEM. A SEPARATE AC CIRCUIT MUST BE PROVIDED FOR THE FIRE ALARM SYSTEM. STANDBY BATTERIES AND THE CHARGING SYSTEM SHALL BE SUPERVISED. 21. UPON ACTIVATION OF ANY FIRE ALARM DEVICE, THE CONTROL PANEL SHALL SOUND THE EVACUATION SIGNALS, FLASH THE EVACUATION LIGHTS, INDICATE THE ZONE OF ACTIVATION AT THE PANEL AND TRIP THE MASTER BOX. 22. THE VISUAL INDICATORS OF THE EVACUATION SIGNALS MUST STAY ILLUMINATED UNTIL THE SYSTEM IS RESET. FIRE ALARM RISER DIAGRAM N.T.S. FIRE ALARM SYSTEM 0,115 AUDIBLE/VISUAL DEVICE, TOP OF DEVICE MOUNTED NOT LESS THAN 90" AFF AND NOT LESS THAN 6" BELOW FINISHED CEILING D415 VISUAL DEVICE, ENTIRE LENS MOUNTED NOT LESS THAN 80" AFF AND NOT MORE THAN 96" AFF KJF 15 CEILING MOUNTED AUDIBLE/VISUAL DEVICE 015 CEILING MOUNTED VISUAL DEVICE ❑F MANUAL PULL STATION, MOUNTING HEIGHT 48" TO CENTERLINE AFF O SMOKE DETECTOR, "D" INDICATES DUCT MOUNTED SMOKE DETECTOR, "R" D,R INDICATES ELEVATOR RECALL, "NS" INDICATES NON -SYSTEM FC-M-1 FIRE ALARM MODULE CONTROL MODULE MM FIRE ALARM MONITOR MODULE RTS REMOTE TEST STATION ANN FIRE ALARM ANNUNCIATOR PANEL FF—AC-P-1 FIRE ALARM CONTROL PANEL FS-D-1 SMOKE DAMPER BOYS LOCKER ROOM XM �_XM 4 NOTES: 1. MINIMUM SIZE CONDUIT SHALL BE 3/4" UNLESS NOTED OTHERWISE. 2. ALL SYSTEM WIRING SHALL BE INSTALLED IN CONDUIT (FIRE ALARM RATED FLRP METALLIC FLEXIBLE CONDUIT) AND IN ACCORDANCE WITH EQUIPMENT SUPPLIER'S APPROVED SHOP DRAWINGS AND WIRING DIAGRAMS. 3. RISER DIAGRAM DOES NOT SHOW ENTIRE SYSTEM. REFER TO FLOOR PLANS FOR EXACT QUANTITIES AND LOCATIONS OF ALL SYSTEM DEVICES. 4. CONTRACTOR SHALL EXTEND EXISTING INITIATION AND NOTIFICATION LOOPS TO NEW DEVICES ROOF FIRST FLOOR BLW, BLW Engineers, Inc. 311 Great Road, Post Office Box 1551 Littleton, Massachusetts 01460 t: 978.486.4301 £ 978.428.0067 www.blwengineers.com HVAC * Electrical * Plumbing * Fire Protection �IENAP RCHITEC7 in Here. Finish Well] 20 Conant Street Danvers, MA 01923 9 7 8 - 7 5 0 - 9 0 6 2 gienap parchitects.com (n N Q N E O Q O O O _J — +, 0 C O O +) O� v M I C / E O cI) U O O O � O W Plot Date: 8/21/20191:22:19 PM © 2018 Gienapp Design Associates, LLC ALL RIGHTS RESERVED. ALL IDEAS, DESIGNS, PLANS AND SPECIFICATIONS ARE THE PROPERTY OF GIENAPP DESIGN ASSOCIATES. RIGHTS OF USE ARE CONDITIONAL AND ARE LIMITED TO A ONE-TIME USE TO CONSTRUCT A SINGLE PROJECT ON THE SITE SO INDICATED. USE OF THE WORK AND ANY DERIVITIVE WORK COVERED UNDER THIS COPYRIGHT FOR OTHER PROJECTS IS PROHIBITED. THE USE OR REPRODUCTION OF THESE PLANS FOR ANY OTHER CONSTRUCTION OR PERMIT APPLICATION IS STRICTLY PROHIBITED WITHOUT PRIOR WRITTEN PERM SSION OF GIENAPP DESIGN ASSOCIATES AND THE ARCHITECT WHOSE SIGNATURE AND SEAL MAY BE AFFIXED TO THESE DRAWINGS. Project: 614.14 Drawn by: MG Check by: MG Date: 12/18/2019 Scale: As indicated FIRE ALARM RISER DIAGRAMS FA1 00