Loading...
HomeMy Public PortalAbout11-0571 Legion Post 154 4:',i ,! ,-, kl ' ft CITY OF TYBEE ISLAND BUILDING PERMIT DATE ISSUED: 10-13-2011 PERMIT#: 110571 WORK DESCRIPTION PLMG-FIRE SUPPRESSION SYSTEM WORK LOCATION 10 VETERANS DR OWNER NAME AMERICAN LEGION POST 154 ADDRESS PO BOX 1225 CITY,ST,ZIP TYBEE ISLAND GA 31328-1225 PHONE NUMBER 912-786-5356 i CONTRACTOR NAME HENDRIX FIRE PROTECTION ADDRESS PO BOX 2348 CITY STATE ZIP STATESBORO GA 30459 FLOOD ZONE BUILDING VALUATION SQUARE FOOTAGE OCCUPANCY TYPE P TOTAL FEES CHARGED $ 106.00 PROPERTY IDENTIFICATION# I PROJECT VALUATION $1,200.00 TOTAL BALANCE DUE: $ 106.00 It is understood that if this permit is granted the builder will at all times comply with the zoning,subdivision,flood control,building,fire,soil and sedimentation,wetlands,marshlands protection and shore protection ordinances and codes whether local,state or federal,including all environmental laws and regulations when applicable,subsequent owners should be informed that any alterations to the property must be approved by the issuance of another building permit. Permit holder agrees to hold the City of Tybee Island harmless on any construction covered by this permit. This permit must be posted in a conspicuous location in the front of building and protected from the weather. If this permit is not posted work will be stopped. The building contractor will replace curb paving and gutter broken during construction. This permit will be voided unless work has begun within six months of the date of issuance. (ID. • 1 Jk1Cl/VIA-43 0 I --i_— Signature of Building Inspector or Authorized Agent: P.O.Box 2749-403 Butler Avenue,Tybee Island,Georgia 31328 (912)786-4573-FAX(912)786-9539 www.cityoftybee.org ‘EE [5' .�=� ;3, City of Ty ee Island Community Developr...�nt Dept. tip, ((;'\a, r,,l Inspection Report :��* I A) 0 �utie� ?tee. P.O. fox 2749 Tv�l?ee Island GA 31328 \;., . _ Fax 9 ( g5• CODE MUNCH: ,. "�/y_ Phone �:�'�,:�8�.���3 ext. �x ���.�,�'8���,.�:�9 0 MEMBER Permit No. { 1 - 0 6 ' J Date Requested ! ( I 1 - 1 I Owner's Name Av ‘.66,--, e ; c v\ Date Needed 1 ?" Gen. Contractor 1- en r y r:,r 2 t'in t-_ Subcontractor Contact Information ! r N1 53 - 0Q Project Address 10 Ve 'i"e ro. n s --Or-- . Scope of Work f QJ .a p o r e ,<Sr. o n 5`� �'- J Inspector i/ L Date of Inspection I / ( r ..' 'i Inspection -1- • n a I Pass , Fee 27/7k �" f hspection , ! �t� Pass Fail Fee Inspection Pass 0 Fail 0 Fee Inspection Pass ❑ Fail 0 Fee h7.i/I 3/ 11: yl ladybltil HENDPIX FIRE PAGE 02/03 • • APPLICATION FOR *IRE PREVENTION 'PERMIT PHONE NO.(912)651-6530 FAX i O. (912)651-6975 PERMIT#• . .PAYMENT ACCEPTED BY.CRECK OR MONEY ORDEH ONLY .. INSTRUCTIONS: PLEASE:CIRCLE, CHECK MARK OR WRITE ALL REQUESTED DATA • L PROJECT ADDRESS: l b f ' a -1 - i # 11L 1r.. PROJECT NAME: A n'e./e ca" 6te j..d•-\ SUBDIVISION ' t l COMPLETE DESCRIPTION OF WORK: - I re_ 5-44�,��;� • Check all that apply: O Sprinklers 0 Alums Vit1uprestion S stem 0 Under ground tank VALUATION OF JOR:(INCLUDE LABO WNIATERkAL/PROFITh S _► 0 �nn • 1 . CLASS OF WORK NEW ADDITION I ALTERATIO* REPAIR OTHER IL Contractor Responsible for work: NAME., V lGt r CI11': 5 C< `�es L COMPANY NAME:14946gri Ff' i STATE: 'Ga._ ZIP: 30 St 3--q ADDRESS: 7p• ea>✓tGTE EPIIONE N(I.: FAX NO.: 4/29 ' 2?l v� of S3� 3/ call I hereby certify that I have answered all of the questions contained}wren}and know the same to be true and correct. All work performed under this permit must comply with State law and local ordinances. Furth er, - I understand that any permit issued,based upon false information or misrepresentation provided by the applicant, will be null and void and subject to penalty as provided'by law and'Ordinance.' ` • Licensed Contractor/Owner Date .1 ' • • f+4-4-1—f-+++++++++++++++++++++-4,+++-1.+-I-1 F++++++—++174-++++++++4-++++44++++++-i-4-4-++++474-4- PERMIT NUMBER ft-o5-71. PROJECT NU1l UER ti.'APPROVED _ FEE DUE$ FEE PAID S • CHECK if revised 8/98/dd • - . • I I 1 All Construction must Comply with the State Fire Safety Standards, the NFPA-101 Life Safety Code +4 Edition and Standard Fire Prevention CodeEdition with State of Georgia Amendments. lj PAGE 01/03 FIRE HENDPI%; 03/09/2006 11:97 9124E+96281 Acol/C c J e) c es-^ • 11.18ARLtLAM U!4L • AGENT V0940 E 2 OA9 VALVE MIU OFF Chatham County Tnspeotions Department REVIEW FOR CODE COMPLIANCE Every effort has been made to identify code violations, no oversight by the reviewer shall be construed as authority to violate, cancel , alter or set aside • any applicable codes or ordinafloes , Tht review and permit should not tpie e4hoittta,i as a warranty or guarariteo. ,dl ik' Reviewed -By ����fi 03/09/2006 11:37 9124896281 HENDRI%= FIRE PAGE 01/03 /ev1 C✓1Gt L e) „0,•� Y FugAnimumum 1 1 __.41,j i/rH 3 AC'FNdlt+tt4 r. i . IOU VALVE : I\ ; • P (7TT I ./7 / SHUT OFF 6 4-..a �.�,._.. ,.f„,., G ill1 t-L., , K. I- Z 1 o ZW gII �= 8 � � CE z r-Jii I° CiD � U 1ict vi 2 Pm - Z in p 2 ,. Wes - _T itqwwir--------ft U 0 0 • , d � ‘ 111111fillib 112 o. : ri,,,sibi. 901-.), 0 0 W IX it I ,...,,,,,, ,s , 104-, a SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-1 4-1-06 REV. 5 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant(1.5 gallon—Part No. "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY 79694 or 3.0 gallon—Part No.79372)is a potassium-based solu- (MECHANICAL) tion designed for fast knock-down and suppression of grease- related fires.The agent is shipped in plastic containers which pro- NOTE:AGENT TANK MUST BE •vide one complete tank charge. (Refer to Section V, Page 5-2.1, ORDERED SEPARATELY 1111' c,,,..-1/1E)OR SEE PAGE 3-4 •for maximum agent fill capacity.)Agent storage life expectancy is twelve years. The distributor must record the batch numbers and RELEASE MECHANISM \ date of shipment receipt to be filed with each installation record. ' t "ANSULEX"LOW PH LIQUID FIRE SUPPRESSANT 4.01M......0.,, \,,/ ' '' ,--.._-1;4-'1 V C:4 �I 'Al • REGULATOR 3.0 GALLON ,f 1.5 GALLON SHIPPING WT.25 LB.(11 kg) • SHIPPING WT.35 LB.(16 kg) SHIPPING WT.19 LB.(9 kg) 000136 000137 FIGURE 1 FIGURE 2 000138 REGULATED RELEASE ASSEMBLY(MECHANICAL) REGULATED RELEASE ASSEMBLY(ELECTRICAL) The ANSUL AUTOMAN Regulated Mechanical Release Assembly The ANSUL AUTOMAN Regulated Electrical Release Assembly (Part No. 429853) contains the regulated release mechanism, (Part No. 429856) is identical to the mechanical version except it expellant gas hose for agent tank hookup, and enclosure knock- also contains a factory installed 120 VAC solenoid and electrical outs to facilitate installing actuation piping;expellant piping;detec- switch. tion system; and additional equipment. This regulated release The solenoid is used to provide electrical actuation of the release assembly is used in single,double,and multiple tank systems and mechanism.The electric switch is used to protect the solenoid by must be mounted to a rigid surface.The release mechanism can opening the circuit to the solenoid once the system is fired. be used to interconnect both the actuation and expellant gas lines Additional electrical switches can be added as required for auto- as required per system design.The regulator is designed to allow matic equipment and gas shut-off accessories,as well as initiating a constant flow of gas into the tank at 110 psi(759 kPa)when the audible and visual alarms. system is actuated.The agent tank must be ordered separately. In single, double, and multiple-tank systems, the provided expel- ''ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY lant gas hose connects the agent tank to the bottom outlet of the ►(ELECTRICAL)' regulator. In double and multiple-tank system configurations, the back outlet of the regulator is used as an expellant gas feed for NOTE:BE ORDERED I CID one additional tank-enclosure or tank-bracket hookup.The enclo- SEPARATELY sure contains the required knockouts to facilitate this connection. OR SEE PAGE 3-4 If a pressure switch is to be attached to the regulator,additional fit- VI"tings are required. REGULATOR SWITCH The tank is mounted within the enclosure. The tank contains an adaptor/tube assembly with a burst disc union. The burst disc helps prevent siphoning of the agent up the pipe due to significant temperature fluctuations in the area where the tank is located.The I SOLENOID tank is mild steel and,under normal conditions,requires hydrosta- tic testing every twelve years. The detection and additional equipment required per system design are connected to the release mechanism. The enclosure contains knockouts to facilitate detection and additional hookups. ; The system can be actuated automatically or manually.Automatic actuation occurs when a fusible link within the detection system j SHIPPING WT.34 LB.(15 kg) separates in a fire condition. Manual actuation of the system occurs when personnel pull on the remote manual pull station e pull ring. FIGURE 3 000130 ►'NOTE:ANSUL AUTOMAN Regulated Electrical Release,Part No.429856,is not ► intended to be used with electric detection. SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-2 REV. 5 4-1-06 ►REMOTE MECHANICAL RELEASE The tank bracket is constructed of mild steel and painted red. It is The Remote Mechanical Release, Part No. 433485, is used to designed for mounting the tank in a minimum amount of space. actuate up to five (5) R-102 regulated actuators. The remote The Bracket Assembly can only be utilized with 3.0 gallon tanks mechanical release utilizes a 101-10 carbon dioxide cartridge as (Part No.429862). the actuation pressure to operate the regulated actuators. The BRACKET ASSEMBLY release is housed in a stainless steel enclosure. MOUNTING 0 al BRACKET I� , p 1 RELEASE MECHANISM T �' 4101.IC, 1 lll� i I1it o % : I SHIPPING WEIGHT I �: 20 LB.(9.1 kg) �' / o -_- FIGURE 4 SHIPPING WT.7 LB.(3 kg) • omSsa ► FIGURE 6 000,51 SINGLE TANK ENCLOSURE ASSEMBLY The Single Tank Enclosure Assembly(Part No.429870)is used in REGULATED ACTUATOR ASSEMBLY double and multiple-tank systems and must be mounted to a rigid The Regulated Actuator Assembly (Part No. 429850) contains the • surface near the regulated release or regulated actuator assembly regulator, pneumatic actuator, expellant gas hose for agent tank 1 its expellent gas line will be connected to. hookup,and enclosure knockouts to facilitate installing expellant pip- The enclosure is designed for mounting either a 1.5 gallon (Part ing. This assembly is used in multiple-tank systems and must be • No.429864)or a 3.0 gallon tank(Part No.429862)in a minimum mounted to a rigid surface. amount of space. The regulator contains two outlets 135°apart. One outlet is used to interconnect the expellant gas hose to the enclosed agent tank. ENCLOSURE ASSEMBLY The other outlet connects an expellant gas line to an additional ► enclosure or bracket assembly.The regulator is designed to allow NOTE:AGENT TANK MUST o ate'' a constant flow of nitrogen into each agent tank.connected (two BE ORDERED 0 tanks maximum)at 110 psi(759 kPa). SEPARATELY OR SEE PAGE 3-4 0 The pneumatic actuator is designed to puncture the expellant gas . cartridge seal upon receiving pressure from the regulated release i assembly actuation piping.The enclosure contains a knockout to 0 facilitate distribution piping hookup. to I REGULATED ACTUATOR ASSEMBLY I MOUNTING ENCLOSURE NOTE:AGENT TANK \ � MUST BE e • ORDERED '\\ PNEUMATIC SEPARATELY I' ACTUATOR r3:'zS.)>, OR SEE PAGE 3-4 i , f ASSEMBLY SHIPPING WT j 13 LB.(6 kg) i , ; I I. 1 p I REGULATOR 00 FIGURE 5 '� 000.12 s'---1 i RED PAINTED BRACKET ASSEMBLY `). SHIPPING WT. The Bracket Assembly (Part No. 429878) is used ;n double and , ; 19 LB.(9 kg) multiple-tank systems and must be mounted to a rigid surface near the regulated release assembly or regulated actuator assembly • FIGURE 7 that its expellant gas line will be connected to. 000140 SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-3 4-1-06 REV. 8 AGENT TANK ASSEMBLY OEM REGULATED ACTUATOR ASSEMBLY The agent tank shipping assembly (3-Gallon, Part No. 429862, The OEM Regulated Actuator Assembly, Part No. 418691, and 1.5 Gallon,Part No.429864)consists of a stainless steel tank includes the regulator,pneumatic actuator,expellant gas hose and and an adaptor/tube assembly. The adaptor/tube assembly con- OEM bracket. Also available is an OEM Regulated Actuator tains a burst disc. The burst disc prevents agent leakage due to Assembly with all the above mentioned components except for the significant temperature fluctuations in the area where the tank is bracket.This assembly is Part No.418522. located. Under normal conditions, the tank requires hydrostatic testing every twelve years.The date of manufacture is stamped on the tank nameplate. The tank is shipped uncharged and must be filled with only \ ED ,-----, ANSULEX Low pH Liquid Fire Suppressant during installation. s t\� TANK ADAPTOR/ TUBE ASSEMBLY ill . I 0 s 3 GALLON SHIPPING WT. 7 LB.(3 kg) 1.5 GALLON SHIPPING WT. 5 LB.(2 kg) SHIPPING WT.4 LB.(2 kg) AGENT ■ FIGURE 10 • TANK 002225 TWO TANK ENCLOSURE ASSEMBLY ' FIGURE 8 The Two Tank Enclosure Assembly, Part No.429872, consists of 0pCi40 two expellant gas hoses,two grommets,and the mounting enclo- OEM RELEASE/BRACKET ASSEMBLY sure.The assembly is used in 9 gallon systems.It can be coupled • (FOR OEM IN-CABINET USE ONLY) with a 3-gallon regulated release assembly or a 3-gallon regulated actuator assembly to give a total of 9 gallons of agent.Agent tanks The OEM Regulated Mechanical Release/Bracket Assembly, Part must be ordered separately. No. 79493, contains the same regulated release mechanism as The tank enclosure is designed to mount in a minimum amount of the standard ANSUL AUTOMAN Regulated Release Assembly. space. The OEM Regulated Electrical Release/Bracket Assembly, Part ■No.418054*, is identical to the mechanical version except it con- tains a factory installed 120 VAC solenoid and electrical switch. These release/bracket assemblies must be installed in a suitable equipment enclosure either horizontally or vertically.They contain all the necessary mounting and conduit holes needed to fully install the assembly. The agent tank is installed separately and i S LB 26 k9) need not be bracketed once it is piped and filled. Note:OEM Release/Bracket Assembly must be installed high enough in cabi- net so that there is sufficient room to install and remove cartridge. •"Note:OEM Regulated Electrical Release/Bracket Assembly,Part No.418054,is ► not intended to be used with electric detection. �■ \ " FIGURE 11 I o��z�, MOUNTING RELEASE BRACKET MECHANISM-► fa* is i' 2 00 REGULATOR $ Ir' 1 Nits_ I SHIPPING WT . I 10 LB.(5 kg) ^I ► FIGURE 9 000144 SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-4 REV. 7 4-1-06 24 VDC REGULATED RELEASE ASSEMBLY(ULC APPROVED ADDITIONAL SHIPPING ASSEMBLIES ONLY) Several complete shipping assemblies are available containing The 24 VDC Regulated Release Assembly, Part No. 429859, is both the release or actuator mechanism and the agent tank.When used where electric,thermostat detection is required via the use of ordering a complete shipping assembly, order the following part a releasing control unit. This assembly consists of a 24 VDC numbers: ANSUL AUTOMAN II-C regulated release mechanism, expellant Shipping Wt. gas hose,and enclosure knockouts to facilitate installing actuation Part No. Description lb. (kg) piping, expellant piping, detection system, and additional equip- ment.Agent tank must be ordered separately. 430299 3.0 Gallon Mechanical Release 33 (15) The system can be actuated automatically or manually.Automatic Shipping Assembly including: actuation occurs when the control panel receives a signal from the 429853 Mechanical Regulated detection circuit.The panel then sends an electrical signal to the Release Assembly 24 VDC regulated release, causing it to actuate. When actuation 429862 3.0 Gallon Tank Assembly occurs,the gas cartridge is punctured,pressurizing the agent tank 430300 1.5 Gallon Mechanical Release 30 (14) and discharging the agent through the distribution piping. Manual Shipping Assembly including: actuation of the system occurs when personnel pull on the remote 429853 Mechanical Regulated manual pull station pull ring. Release Assembly 429864 1.5 Gallon Tank Assembly NOTE:AGENT TANK MUST BE 430309 3.0 Gallon Regulated Actuator Alp-- ORDERED SEPARATELY ( ) Shipping Assembly including: SHIPPING wT. 429850 Regulated Actuator Assembly 4ii 34 Ls.(15 K9) 429862 3.0 Gallon Tank Assembly 36 16 Imo 1 430316 1.5 Gallon Stainless Steel Enclosure 18 (8) Shipping Assembly including: 429870 Single Tank Mounting Box �, Assembly �i 429864 1.5 Gallon Tank Assembly 418511 Hose Assembly • 430317 3.0 Gallon Stainless Steel Enclosure 20 (9) FIGURE 12 Shipping Assembly including: 002279 429870 Single Tank Mounting Box Assembly 429862 3.0 Gallon Tank Assembly 418511 Hose Assembly 430324 6.0 Gallon Stainless Steel Enclosure 40 (18) Shipping Assembly including: 429872 Two Tank Mounting Box Assembly 429862 3.0 Gallon Tank Assembly(2) 430332 3.0 Gallon Mounting Bracket Shipping 20 (9) Assembly including: 429878 3.0 Gallon Mounting Bracket Assembly 429862 3.0 Gallon Tank Assembly " SECTION III SYSTEM COMPONENTS UL EX.3470 ULC CEx747 Page 3-5 3-1-07 REV.7 GAS CARTRIDGES NOZZLES The R-102 system uses gas cartridges to store nitrogen or carbon There are 11 types of discharge nozzles each designed to distrib- dioxide expellant gases under pressure until the system is actuat- ute the liquid agent in a uniform pattern throughout the hazard ed,at which time the cartridge seal is punctured and the released area: gas expels liquid agent from one or more tanks through the dis- 1. 1W Nozzle 7. 245 Nozzle charge piping and out the discharge nozzles. 2. 1N Nozzle 8. 260 Nozzle Four nitrogen gas cartridges and three carbon dioxide gas car- 3. 1/2N Nozzle 9. 290 Nozzle tridges are available as shown in Figure 13. 4. 3N Nozzle 10. 2120 Nozzle Cartridges noted as TC/DOT are both Transport Canada(TC)and 5. 2W Nozzle 11. 1F Nozzle Department of Transportation (DOT) approved. Cartridges noted 6. 230 Nozzle as DOT are Department of Transportation approved only. Cartridge selection options are provided in Section IV under Tank Although these nozzles are similar in appearance and have certain common parts, the tip of each nozzle is designed for a " and Cartridge Requirements, specific application and must only be used in those areas. See NITROGEN GAS CARTRIDGES Nozzle Application Chart in Section IV  System Design, for individual nozzle usage. fiI } 4 1 318-18NPT I 7 7!8 IN. I I FEMALE THREAD (20 cm) Li 11 3/8 IN. 10 1/2 IN. ./j (28.9 cm) (27 cm)I ( 14 5/8 IN. ) i , (37.1 cm) 2 1/21N. . INTERNAL CUP (6.4 cm) f�� 1.4 -_-..,..,' STRAINER 21/21N. 4 3/16 IN. . INSIDE (6.4 cm) (10.6 cm) 1 RECESS FOR -0-��/ ��/-' 39/16 IN. CAP VLOOP XXXX-X VENDOR (9 cm) CODE LT-20-R LT-30-R DOUBLE-TANK LT-A-101-30 NOZZLE (IF PRESENT) CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE STAMPING PART N0.423429 PART NO.423435 PART NO.423493 PART NO.423491 . (TCIDOT) (TC/DOT) (TC/DOT) (TC/DOT) co0145 000146 000047 000148 FIGURE 14 000002 " CARBON DIOXIDE CARTRIDGES Nozzle Identification Chart Nozzle Nozzle Nozzle Nozzle* Flow 9 IN 7l61N. I Type Part No. Stamping No. Nozzle Identification (22.9 m) (zo cm) I 1W Nozzle 419336 1W 1 Chrome-Plated Body - (219.5 11 5/8 cm>IN. 1N Nozzle 419335 1N 1 Chrome Plated Body 3.- 1 1/2N Nozzle 419334 1/2N 1/2 Chrome-Plated Body Metal blow-off caps are not allowed with the 1/2N nozzle 2 IN. 2 1/2 IN. (5.1 cm) (6.4 cm) ��,% 3N Nozzle 419338 3N 3 Chrome-Plated Body 2 1/2 IN. 2W Nozzle 419337 2W 2 Chrome-Plated Body (6.4 cm) 230 Nozzle 419339 230 2 Chrome-Plated Body 01-20 CARTRI 101-10 PART NO.23439 TRIDGE(TTC/DOT) 1PART NO.4 344410 1PART NOR 4231443E 245 Nozzle 419340 245 2 Chrome-Plated Body PART NO.15850(DOT) (TC/DOT) (TC/DOT) 260 Nozzle 419341 260 2 Chrome-Plated Body 000149 000160 0 001" 290 Nozzle 419342 290 2 Chrome-Plated Body FIGURE 13 2120 Nozzle 419343 2120 2 Chrome-Plated Body 'Additional cartridge shipping assemblies are available for 1F Nozzle 419333 1F 1 Chrome-Plated Body " European and Australian requirements. 'Nozzle stamping may contain an additional letter indicating a vendor's code. Cartridge European Australian Description Part No.* Part No.* SILICONE LUBRICANT LT-20-R 428440 428948 Dow Corning Compound 111, Part No. 78112, is available in a LT-30-R 428441 426553 5.3-ounce tube. Compound has excellent qualities for sealing and Double Tank 428446 426563 lubricating system components. LT-A-101-30 428442 426555 10l-10 CO2 428443 N/A 101-20 CO2 428445 N/A 101-30 CO2 428444 N/A " '`Non-UL Listed SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-6 REV. 6 3-1-07 SWIVEL ADAPTOR CONDUIT OFFSET ASSEMBLY The Swivel Adaptor Assembly, Part No. 418569, consists of a The conduit offset assembly, Part No. 79825, is used to change swivel nut,swivel body and swivel ball.All are chrome-plated.The direction of the wire rope on detection,mechanical gas valve,and swivel adaptor allows any nozzle to be rotated approximately 30° remote pull station lines.The conduit offset assembly can only be in all directions. Swivel Adaptors must be ordered as a Swivel used in the area where the conduit attaches to the regulated Adaptor Shipping Assembly, Part No.423572, which contains 25 release assembly. When using the conduit offset assembly, the Swivel Adaptors. maximum number of pulley elbows is still allowed. The Conduit Offset Shipping Assembly, Part No. 79825, consists of 6 conduit /� 3/8-18 NPT offsets. FEMALE THREAD 4 tt\A ` CONDUIT �, .- COUPLING ' 3/8-18 NPT _CONDUIT MALE THREAD OFFSET 30 DEGREE ROTATION FIGURE 15 000003 I CONDUIT RUBBER BLOW-OFF CAPS CONNECTOR • The Rubber Blow-Off Cap,Part No.77676,help keep the orifice of the nozzle free of grease or other substances that could interfere with agent distribution.A retaining strap attaches the blow-off cap FIGURE 18 to the nozzle. Rubber Blow-Off Caps must be ordered as a p00153 Shipping Assembly, Part No. 77695, which contains 50 blow-off caps, or Part No.77411,which contains 12 blow-off caps. "QUIK-SEAL"ADAPTOR The"Quik-Seal"adaptor is a listed mechanical bulkhead fitting that produces a liquid-tight seal around both distribution piping and detection conduit which runs through restaurant hoods and ducts. G�� `�� The "Quik-Seal" adaptor accepts threaded pipe or conduit. The adaptor is available for 1/4 in. (Part No. 78195), 3/8 in. (Part No. 77284), 1/2 in. (Part No. 77286), or 3/4 in. (Part No. 77288) pipe or conduit sizes. When using with EMT conduit, a conduit con- nector must be installed in each end of the adaptor. The "Quik- �P Seal"Adaptor Shipping Assembly must be ordered as stated . below: FIGURE 16 Shipping D00°° Assembly Hole Size •CB METAL BLOW-OFF CAP Size Part No. Qty. Required The CB Metal Blow-off Cap Package,Part No.433208,is used for 1/4 in. 78196 24 3/4 in. all high temperature environments. The metal blow-off cap con- 3/8 in. 77285 24 1 1/8 in. 'tains a special 0-ring placed inside the cap which integrates with 1/2 in. 77287 24 1 1/8 in. the nozzle to create a seal and to help hold the blow-off cap in 3/4 in. 7728• 4 1 3/8 in. position. ' COMPRESSION NUT ►The CB Metal Blow-off Cap Package, Part No. 433208, contains _ 10 blow-off caps. .—. ADAPTOR BODY GASKET-� LOCKWASHER ►Also available is a 10 pack of CB Stainless Steel Blow-Off Caps, NUT-I.�-� Part No.434707. =-- FIGURE 19 '' 00015: �/ STAINLESS STEEL WIRE '� - METAL CAP ■ FIGURE 17 00.631 SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-7 4-1-06 REV.5 "COMPRESSION-SEAL"ADAPTOR This adaptor is a mechanical bulkhead fitting that produces a liquid-tight seal around pipe and conduit when installing distribu- tion piping and detection conduit through restaurant hoods and ducts. The "Compression-Seal" adaptor is a straight-through design requiring no cutting or threading of conduit or pipe. The adaptor is available for pipe sizes of 1/4 in. (Part No. 79148), 3/8 in. (Part No. 79150), 1/2 in. (Part No. 79146), and EMT conduit size of 1/2 in.(Part No.79152).Each"Compression-Seal"Adaptor Shipping Assembly must be ordered as stated below: Shipping Assembly Hole Size Size Part No. Qty. Required 1/4 in. Pipe/1/2 in.tube 79149 24 3/4 in. 3/8 in. Pipe/5/8 in.tube 79151 24 1 1/8 in. 1/2 in. Pipe 79147 24 1 1/8 in. 1/2 in. EMT Conduit 79153 24 1 1/8 in. •_ ADAPTOR BODY GASKET LOCKWASHER WNW NUT FIGURE 20 moss "HOOD SEAL"ADAPTOR ASSEMBLY This adaptor is a mechanical bulkhead fitting that produces a liq- uid-tight seal around 1/2 in.EMT conduit when installing the detec- tion line through restaurant hoods and duct.The adaptor accepts a high temperature pulley elbow and,when used, correctly posi- tions the elbow or conduit in line with the conduit adaptor hole in the detector bracket.The"Hood Seal"eliminates the need for mul- tiple elbows when penetrating the top of a hood when installing the detection line. "Hood Seal"Adaptors are available in quantities of 6 as Shipping Assembly Part No.423253. I SEAL NUT SEAL Han WASHER ADAPTOR __ 11. BODY IIII=I•1= GASKET PULLEY ELBOW \ p' (NOT PART 41I1I� 111 II OF ASSEMBLY) USE ONLY PULLEY ELBOW,PART NO.423250 FIGURE 21 00015° SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-8 REV. 7 4-1-06 DETECTORS CLIP-ON STYLE-PART NO.56837 AND 56838 The detector consists of three basic components:the bracket,link- age, and fusible link. (Fusible links are not included and must be ordered separately.)The bracket holds the entire assembly to the LINKAGE r SIBLE mounting surface. The linkage is used to support the fusible link. K BRACKET The fusible link is designed to separate at a specific temperature and release the wire rope,thereby actuating the regulated release /�•, mechanism. �" 0�0167 There are three styles of detectors available:the clip-on style,the HINGED STYLE-PART NO.15373 AND 15375 hinged style,and the scissor style. The clip-on style allows the wire rope to be strung completely 0 through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. LINKAGE FUSIBLE BRACKET LINK The hinged style detector requires the wire rope to be strung to the detector bracket,and then"threaded"through the linkage assem- bly before continuing to the next detector bracket. The scissor style allows the wire rope to be strung completely 0158 through the detection system conduit and brackets first and the detector linkage assemblies are then clipped on later. SCISSOR STYLE-PART NO.417368 AND 417369 Each style of detector consists of two types of assemblies: BRACKET The Terminal Detector (Part No. 56838, 15375, or 417368) LINKAGE 046 includes a test link and is placed last in a series of detectors.This detector is sometimes referred to as the end-of-line detector and is thus named because it is at the point at which the wire rope"ter- FUSIBLE minates,"or is anchored at the detector bracket. Only one termi- LINK nal detector is required per detection system. The Series Detector(Part No.56837, 15373, or 417369) is any ► °`22 detector located in-line between the regulated release assembly FIGURE 22 and the terminal detector. PULLEY ELBOWS When using Part No. 56837 and 56838 style detectors, a total of There are two types of pulley elbows used to change the direction 12 detectors can be in one detection system: 11 series detectors, of the wire rope by 90°.ANSUL recommends for temperatures not Part No.56837 and 1 terminal detector, Part No.56838. in excess of 700 °F (371 °C). Part No. 415670 has socket ends When using Part No. 15373 and 15375 style detectors, a total of with set screws for 1/2 in.conduit,and Part No.423250 has com- 5 detectors can be in one detection system: 4 series detectors, pression ring ends also for 1/2 in. conduit. Pulley elbows must be Part No. 15373 and 1 terminal detector, Part No. 15375. ordered in quantities of 50 as Shipping Assembly Part No.415671 When using Part No. 417368 and 417369 style detectors, a total (socket end type)and Part No.423251 (compression end type). of 15 detectors can be in one detection system: 14 series detec- PART NO.415670 PART NO.423250 tors, Part No.417369 and 1 terminal detector, Part No.417368. fl x¢; 111 E®) .:. 000160 00:.161 FIGURE 23 SECTION III—SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-9 4-1-06 REV.4 PULLEY TEE MECHANICAL GAS VALVES The Pulley Tee(Part No.427929)is used to change the direction The mechanical gas valves are designed to shut off the flow of gas of two wire ropes by 90°. It must be used in areas where the tern- to the appliances upon actuation of the regulated release assem- peratures are within the range of 32°F to 130°F (0°C to 54°C). bly. The valves are available in sizes of 3/4 in., 1 in., 1 1/4 in., 1 Pulley tees can be used in mechanical gas valve actuation lines 1/2 in., and 2 in.ANSUL style; and 2 1/2 in. and 3 in.Asco style. and remote manual pull station lines. Pulley tees cannot be used The valves are rated for natural and LP gas. Both styles are UL within a detection line. Listed and includes the air cylinder, tubing, and fittings for con- nection to the release mechanism.aIir Maximum I C } III Part Operating No. Description Pressure 55598 3/4 in.Gas Valve(ANSUL) 10 psi(.69 bar) 1E1 55601 1 in. Gas Valve(ANSUL) 10 psi(.69 bar) 55604 1 1/4 in. Gas Valve(ANSUL) 10 psi(.69 bar) 1. FIGURE 24 55607 1 1/2 in.Gas Valve(ANSUL) 10 psi(.69 bar) `C04a7 55610 2 in. Gas Valve(ANSUL) 10 psi(.69 bar) STAINLESS STEEL CABLE 25937 2 1/2 in. Gas Valve(ASCO) 5 psi(.35 bar) 25938 3 in.Gas Valve(ASCO) 5 psi(.35 bar) The 1/16 in.stainless steel cable is run from the terminal detector, through conduit, all series detectors and pulley elbows, and into A B C the regulated release mechanism trip lever.When any fusible link Valve Size in. (mm) in. (mm) in. (mm) separates, the tension on the cable is relaxed, and the trip lever 3/4 in. 3 3/4 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) actuates the regulated release mechanism.The cable can also be 1 in. 3 3/4 (95.3) 6 3/8 (161.9) 5 1/2 (139.7) used for mechanical gas valves and remote manual pull stations. 1 1/4 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) The cable is available in 50 ft.(15 m)(Part No. 15821)and 500 ft. 1 1/2 in. 4 7/8 (123.8) 7 3/8 (187.3) 6 3/8 (161.9) • (152.4 m)(Part No.79653)lengths. 2 in. 5 7/8 (149.2) 7 7/8 (200.0) 6 11/16 (169.9) ' 2 1/2 in. 7 13/16 (198.4) 9 1/16 (230.2) REMOTE MANUAL PULL STATION 3 in. 7 25/32 (197.6) 9 1/16 (230.2) The remote manual pull station(Part No.4835 or Part No.54011) imi is required for manual actuation of the regulated release assem- bly.The remote manual pull station should be mounted at a point of egress and positioned at a height determined by the authority 111 IIII having jurisdiction. Trim rings, Part No. 427074 (pack of 10), are e • • available. ' 4, Ali PART NO.4835(WITHOUT CABLE) _ '_�` ;. • PART NO.54011(WITH 50 FT OF CABLE) I ! }„, L l9.. �- P� ;• B � A-► ^? 3/4 IN.THRU 2 IN. 2 1/2 IN.THRU 3 IN. 004209- 004209 (� FIGURE 26 METAL STAMPED 000153 • FIGURE 25 i • SECTION III–SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-10 REV. 3 4-1-06 ELECTRICAL GAS VALVES ELECTRICAL SWITCHES The electrical gas valves are designed to shut off the flow of either The electrical switches are intended for use with electric gas natural or LP gas to the appliances upon actuation of the regulat- valves, alarms, contactors, lights, contractor supplied electric ed release assembly.The valves are available in sizes of 3/4 in., power shut-off devices and other electrical devices that are 1 in., 1 1/2 in.,2 in., and 3 in.The valve is held open by an ener- designed to shut off or turn on when the system is actuated. gized solenoid and upon system actuation,the switch contacts in Switches are available in kits: One Switch Kit, Part No. 423878, the regulated release assembly open, thus de-energizing the cir- Two Switch Kit, Part No. 423879, Three Switch Kit, Part No. cuit to the gas valve solenoid, causing the valve to close.Valves 423880, and Four Switch Kit, Part No. 423881. Mounting hard- are available in 120 VAC and are UL Listed. ware and 12 in. (305 mm)long wire leads are provided with each Part Max. Operating kit. Each switch has a set of single-pole, double-throw contacts No. Description Pressure rated at: 13707 3/4 in. Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) ULlcULlCSA Rating ENEC Rating 13708 1 in.Solenoid Gas Valve(ASCO) 25 psi (1.7 bar) 250 VAC, 21A Resistive IE4T105p Approved ►550360 1 1/4 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) 250 VAC, 2 HP 250V,21A Resistive 13709 1 1/2 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) 125 VAC, 1 HP 8A Motor Load 13710 2 in.Solenoid Gas Valve(ASCO) 25 psi(1.7 bar) •550363 2 1/2 in. Solenoid Gas Valve(ASCO) 5 psi(.35 bar) 17643 3 in.Solenoid Gas Valve(ASCO) 5 psi(.35 bar) COMMON r N-o. Valve A B f Size in. (mm) in. (mm) ' 3/4 in. 3 5/16 (81.0) 3 5/8 (92.1) N.C. 1 in. 5 (127.0) 6 27/32 (173.8) •1 1/4 in. 7 13/16 (198.4) 7 29/32 (200.8) 1 1/2 in. 5 (127.0) 5 19/32 (142.1) 2 in. 6 3/32 (78.6) 5 15/16 (150.8) ► 2 1/2 in. 7 13/16 (198.4) 7 29/32 (200.8) FIGURE 29 • 001612 3 in. 7 13/16 (198.4) 7 29/32 (200.8) ALARM INITIATING SWITCH .-- The Alarm Initiating Switch Kit, Part No. 428311, can be field mounted within the ANSUL AUTOMAN release.This switch must •be used to close a supervised alarm circuit to the building main fire B alarm panel when the ANSUL AUTOMAN release actuates. This EN action will signal the fire alarm panel that there was a system actu- ■', ation in the kitchen area. The switch kit contains all necessary i mounting components along with a mounting instruction sheet. IN 11111 The switch is rated 50 mA,28 VDC. SPACER TOWARD ANSUL WHEN SPACER AND AUTOMAN -.1-A R SWITCH ARE PROPERLY \ MOUNTED.THIS DIVIDER • FIGURE 27 MUST BE BETWEEN THE \ N.Q.AND N.C.TERMINALS \ COM MANUAL RESET RELAY � •The Manual Reset Relay,Part No.426151,is required when using \-� 3 ,J N.Q. an electrical gas valve shut-off system.After the electric gas valve \,\ '\ �—� �� has closed, either due to system actuation or power failure, the -� valve cannot be re-opened, allowing gas to flow, until the reset relay button is manually pressed, re energizing the circuit. The reset relay is available 120 VAC. The manual reset relay is also VOL '\ \\�N.C. recommended for electrical shut down. f �. ALARM INITIATING SWITCH 401/>i,v FIGURE 30■ 004690 ■ FIGURE 28 SECTION III–SYSTEM COMPONENTS UL EX. 3470 ULC CEx747 Page 3-11 4-1-06 REGULATOR TEST KIT HOSE/GROMMET PACKAGE The Test Kit Assembly (Shipping Part No. 56972) is required to The Hose/Grommet Package, Part No. 418511, consists of a 24 test the regulator setting and nitrogen flow during 12-year mainte- in. rubber hose and 2 (two) grommets. This package is required nance examinations. This will ensure that the regulator is func- when mounting an AUTOMAN Regulated Release (or Regulated tioning properly. Actuator) and a tank enclosure (or tank bracket) side by side in either a manifolded system or an independent piping system. (0) 4.11•i PIP BURSTING DISC _� *40 The R-102 Bursting Disc is installed in the tank adaptor assembly. The bursting disc eliminates the siphoning of the agent up the pipe during extreme temperature variations. The bursting discs are I % available in packs of 10, Part No.417911. FIGURE 31 FUSIBLE LINK Select correct UL Listed fusible link(s)for installation in detector(s) ► FIGURE 33 according to the temperature condition chart below: 000172 K STYLE Fusible Link To Be Used NOZZLE AIMING DEVICE Fusible Shipping Where The Nozzle Aiming Device, Part No.431992, is available to prop- Link Assembly Temperature Temperature erly aim each nozzle to the correct aiming point. The device Part No. Part No. Rating Does Not Exceed clamps to the nozzle and emits a small laser light that reflects on . 415739(1) 415739(1) 165 °F (74°C) 100°F (38 °C) the surface that it is aiming at.The nozzle can then be rotated to 415740(1) 415740(1) 212°F(100°C) 150°F (66°C) point at a predetermined aiming point and then tightened to hold 415741 (1) 415744(25) 280°F(138°C) 225°F(107°C) that angle.The aiming device adaptor attaches to the nozzle.The ■415742(1) 415745(25) 360°F(182°C) 290°F(143°C) shipping assembly consists of the aiming device and the adaptor. '415743(1) 415746(25) 450°F(232°C) 360°F(182°C) ML STYLE ~+♦0, Fusible Link To Be Used i Fusible Shipping Where � Link Assembly Temperature Temperature part No. Part No. Rating Does Not Exceed ADAPTOR 550368(1) 551522(10) 165°F (74°C) 100°F (38°C) NOZZLE a*'' 551523(10) 212°F(100°C 150°F (66°C) AIMING V% 550365(1) ( ) ( ) ( DEVICE 550366(1) 551524(10) 280°F(138°C) 225°F(107°C) • FIGURE 34 ►550009(1) 551525(10) 360°F(182°C) 290°F(143°C) 00o-52' 550367(1) 551526(10) 450°F(232°C) 360°F(182°C) STAINLESS STEEL ACTUATION HOSE 56816(1) 551527(10) 500 °F(260°C) 400°F(204°C) ► 56816(1) 73867(25) 500°F(260°C) 400°F(204°C) The Stainless Steel Actuation Hose is used to connect the actua- tion line compression tees between each pneumatic actuator.The hose has the same thread,7/16-20, as the fittings.The actuation O Ce��( 1)) O TEMPERATURE RATING STAMPED ON hose allows flexibility between the AUTOMAN and each regulated actuator. AN$UU ►Hose Part No. Length Couplings 31809 32335 32336 ►430815 16 in. (41 cm) 7/16-20 x 7/16-20 Females 20 in.(51 cm) 7/16-20 x 7/16-20 Females FUSIBLE LINK BODY 24 in.(61 cm) 7/16-20 x 7/16-20 Females j--1 42 in.(107 cm) 7/16-20 Female x 1/4 in. NPT 0 Fitting Part No. Description KSTYLE ML STYLE 31810 Male Elbow(7/16-20 x 1/4 in.NPT) 0 0170 000,7, ► FIGURE 32 31811 Male Tee(7/16-20 x 7/16-20 x 1/4 in. NPT) 415371 Tee(7/16-20 x 1/8 in.Male NPT x 1/8 in. Female NPT) MAXIMUM REGISTERING THERMOMETER •32338 Male Straight Connector(7/16-20 x 1/4 in.NPT) 25627 1/4 in.Check Valve The Maximum Registering Thermometer, Part No. 15240, is used - to indicate the highest normal temperature for the protected area. m.+ ,.;. . .• <!,,�; ' Once this is established, the correct rated fusible link can be = : 4,,,‘.,��.o�y! chosen. 7/16-20 7116-20 ► FIGURE 35 01C431